Public Administrative Department Local Bodies Closing in 2 days TDR #57943796

Tender For Construction Of Market Complex Building Near Critical Health Care Centre, Pattamundai Municipality

Issued by Local Bodies · Kendrapara, Odisha
Tender Value
1.22 Crore
Estimated cost
Bid Submission
20 Oct 2026
2 days left
EMD
1.22 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kendrapara → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Market Complex Building Near Critical Health Care Centre, Pattamundai Municipality

BOQ

Name of Work:- CONSTRUCTION OF MARKET COMPLEX BUILDING NEAR CRITICAL HEALTH CARE CENTRE, PATTAMUNDAI MUNICIPALITY
Sl. No. Item Description
1Estimate for CIVIL WORK Single under reamed 450mm Dia pile foundation upto a depth of 8m with R.C.C. M25 using 12mm size black hard granite (crusher broken)stone chips including cost of boreholes and cost of M.S. rod/Tor steel and labour sundries T&P etc complete and as per direction of engineer -in- charge.
2Earth work excavation in all kind of soil within initial lead of 50 m and initial lift of 1.5 m including rough dressing and leveling the bed...etc complete in all respect and as per the direction of Engineer-in-charge.
3Supplying, & filling in foundation and plinth with good quality river sand including watering, ramming with cost, conveyance, royalties, taxes of all materials and cost of all labour with T&P, sundries required for the work etc., complete (Measurement will be taken on finished compacted section) as per specification and direction of Engineer-in-charge.
4C.C (1:4:8) with 4cm size HG Crusher BROKEN metal including all cost, conveyance,royalty & taxes etc.comp.to work site as per specification approved by the department & direction of E.I.C.
5Brick work with Fly Ash bricks of size 25cmx12cmx8cm and crushing strength not less than 75 kg/cm2 in C.M.(1:4) in foundation and plinth including all charges.
6Providing, lifting, hoisting and laying Reinforced Cement Concrete of M-25 grade in Column base, Column Footings, Raft Foundation,Stem of the Columns, beams, chaujja, fin, lintel, stair case, jali , shelves and slab etc as per approved designs and drawings having a minimum compressive strength ( in work test) 20N. / Square mm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 456 and I.S. 516 using screened & washed sharp river sand for mortar and 10 mm. to 20 mm. size black hard crusher broken granite stone chips of approved quality from approved quarry, washed and cleaned to be mixed in concrete mixture with approved quality of cement including hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 28 days including, centering and shuttering then after dismantling and removing the debrises away from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials , cost of all labours, scaffolding, sundries, T&P required for the work etc. complete in all respect but the excluding cost & conveyance of M.S. rods or Tor Steel and Binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or Tor steel and binding wires and tying the grills and placing in proper position as directed by the Engineer-in-charge. (A) Coloumn Footing
7(B) Column (Ground Floor) C1
8First floor C1
9Second floor C1
10(C ) Plinth Bend
11(D) Lintel (Ground Floor)
12(First floor)
13(Second floor)
14(E ) Roof Beam (Ground Floor)
15First floor
16Head Room
17(F) Roof Slab (Ground Floor)
18(First floor)
19(Second floor)
20(G) Staircase (Ground Floor)
21(First floor)
22(H) Fin (Ground Floor)
23(First floor)
24Providing and fixing Centering and shuttering including strutting, propping etc. and removal of form the site after completion of respective work as the direction of engineer in charge. (A)Coloumn Footing
25(B) Coloumn (Ground Floor) C1
26First floor C1
27Second floor C1
28(C ) Plinth Bend
29(D) Lintel (Ground Floor)
30(First floor)
31(Second floor)
32(E ) Roof Beam (Ground Floor)
33First floor
34Second Floor
35(F) Roof Slab (Ground Floor)
36(First floor)
37(Second floor)
38(G) Staircase (Ground Floor)
39(First floor)
40(H) Fin (Ground Floor)
41(First floor)
42Cutting,Straightening coiled or bent up M.S plain HYSD/TMT reinforcement bars welding or jointing if necessary bending,binding,tying the grills as required for R.C.C works,providing fan hooks where necessary and hoisting, lowering and placing in proper position according to approved designs and drawings including cost, conveyance,loading, unloading & taxes of M.S plain/HYSD/TMT reinforcement bars and binding wires of 18 to 20 gaugo required for the work and cost of all labour, sundries, T&P and scaffolding complete in all respect as directed by the Engineer in charge (payment will be made according to the actual weight of M.S plain/HYSD/TMT reinforcement bars consumed in the work only. (Ground floor)
43First floor
44Second floor
45Brick work with Fly Ash bricks 25cm x 12cm x 8cm size having crusing strength not less then 75Kg/cm2 in cement mortar (1:6) in superstructure per cum. (Ground floor)
46First floor
472nd Floor
48Providing 12mm thick cement plaster in cement mortar (1:6) in all floors finished smooth to out side smooth surface of brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge. ( Ground floor)
49First floor
50Second Floor
5116mm thick cement plaster (1:6) on brick work including all cost conveyance royalty & taxes etc. comp. to work site per 1sqm. (Ground floor)
52First floor
53Second floor
546mm thick cement plaster (1:4) onRCC concrete drain work including all cost conveyance royalty & taxes etc. comp. to work site per 1sqm. (Ground Floor)
55First floor
56Second floor
57Wall painting 2 coats with weather coat over a coat of primer to inside and out side smooth surface with all cost of labour, T&P material etc complete. (Ground floor)
58First floor
59Second floor
60Wall painting 2 coats with Plastic emulsion paint of approved shade over a coat of primer on new work to give an even shade with all cost of labour, T&P material etc complete. (Ground floor)
61First floor
62Second floor
63M.S. Grill gate made out of M.S. flat conforming to IS 2062/20006 painted with red oxide primer as pe the design approved. (Ground floor, First floor & Second floor)
64Painting two coats with approved synthetic enamel paints of Asian / Berger/Dulox make and of approved colour, shade to new Iron including sand papering, polishing the surface, cost, conveyances, taxes of all materials and cost of all labour with T&P etc, complete as per specification & direction of Engineer-in-charge. Note :- Sample of Paint & Primer shall be approved before procurement and use. (Grills)
65Supplying, fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fittings and fixtures.(SR-2022 New Miscellaneous Item-12 , Page-235). (Ground floor, First floor & Second floor)
66Fixing vitrified tiles in floors treads or steps and landing on 25mm thick bed of cement mortar 1:1 (1cement : 1sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete. (Ground floor)
67First floor
68Fixing vetrified tiles in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and polishing complete. (Ground floor)
69First floor
70Fixing of ceramic floor tiles in floors treads or steps and landing on 25mm thick bed of cement mortar 1:1 (1cement : 1sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete. (Ground floor)
71First floor
72Fixing Ceramic wall tiles in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and polishing complete. (Ground floor)
73First floor
74Supply fitting and fixing of rolling shutter.
75Filling in foundation and plinth with excavated earth including watering and ramming complete in all respects as directed by the Engineer-in-Charge.
76Removing surplus excavated earth from site and depositing the same at approved dumping yard within 5 km lead including loading, unloading, carriage and all incidental charges complete.
77Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, labour, T&P etc. required for the complete in all respect.
78Estimate for PH PVC ASTM Pipes and fittings (Riser & Down)Non-Concealed 40 mm dia CPVC pipe (Riser pipe)
7925 mm dia CPVC pipe ( Down Pipe)
80PVC ASTM Pipes and fittings (Riser & Down)Concealed 20 mm dia CPVC Pipe
81Supplying, Fittings & Fixing with all labour, T&P as per specification, the following Brass / CP(Jaquar) /G.M. fittings at appropriate locations along the pipe lines at all floors and at all heights of approved make confirming to relevent IS specification. etc.complete in all respect as per direction of the Engineer in charge. (a)15 mm dia C.P. 2 way Bib Cock (Short body) or Health Processor (3.2.14)
82(a) 15 mm dia CP Bib cock ( Long Body)
83(a) 15 mm dia CP Angle stop cock
84(a)15 mm dia Conc. Stop cock.
85(a)15 mm dia C.P. Pillar cock
86(a) 15 mm dia C.P. Shower with arm
87600 mm long CP Towel rail
88(a)CP Soap holder
8915 mm dia C.P. Towel Ring
90600 mm long C.P. Glass shelf with C.P frame
91(a)110 mm dia C.P. waste
9240mm dia GM FW valve
93Supplying, Fittings & Fixing with all labour, T&P as per specification, the following flexible PVC connection pipes and waste pipe making connection with pillar cock, cistern. Wash hand basin at all height and all floors with all jointing materials etc. complete as per direction of the Engineer -in- charge. (a) 450-600 mm long 15mm dia PVC connection pipe
94(a)40 mm dia flexible PVC waste pipe 1 mtr each.
95Supplying, Fittings & Fixing of 10 Ltr. Capacity low level P.V.C cistern white colour, to wall at all floors and at all height with all accessories etc. complete in all respect as per direction of the Engineer -in- charge.
96Supplying, Fittings & Fixing of following sizes of porcelain wash hand basin confirming to relevant IS specification of Nycer/ Cera/ Parryware make to the brick / concrete wall etc. complete as per direction of the Engineer in charge. (a) Standard ( 550x400mm) size basin
97Porcelain Squatting Urinal(600x355mm)
98Supplying , fitting and fixing the standard size of European pattern porcelain wash down water closet confirming to relevant IS specification of Nycer/ Cera / Parryware make having 'S' or 'P' trap etc with all required materials, labour T&P etc. complete as per direction of the Engineer in charge.
99Supplying ,fitting and fixing with all labour and T & P 4mm thick bevelled edge sheet glass mirror (508mmx406) of relevant IS specification to the brick concrete wall with full sheet hard board and CP down shaped screw on wooden /PVC plug etc. complete as per direction of the Engineer in charge.
100Supplying all labour T & P etc for cutting holes in brick masonry wall/ RCC work for passing of GI /pvc Pipes of 15 mm to 50 mm dia and making good to the damages with C.M. (1:4) as per direction of the Engineer in charge.
101Supplying, fitting & fixing of ISI marked PVC,CLASS-B(SWR) pipes with all materials, labour & T&P on concrete / Brick walls and grounds with nails, bobbins and wooden plugs as required including , scaffolding with proper plumbing fittings for exposed pipes complete in all respect as per direction of the Engineer in charge. 110mm dia PVC pipes Ground Floor
102Supplying, fitting & fixing of following size of UPVC,CLASS-B(SWR) fittings of ISI marked to UPVC pipes (on concrete / Brick walls and grounds) with all materials labour T&P including cutting of the walls, with supply of nails, bobbins and wooden plugs as required including scaffolding etc. complete in all respect as per direction of the Engineer in charge. 110 mm dia Single Junction with door
103110 mm dia plain Door Bend
104110 mm dia 'P' Trap
105110 mm dia Off set
106110 mm dia Cowl
10775 mm dia Single Junction with door
10875 mm dia elbow
109Fixing rational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701-1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts , fixing ball valve etc., including hoisting upto a height of 5 meters above ground level and palcing the tank to the required position etc all complete asper specification and direction of the Engineer In charge. (1000 LTR) @Per LTR RS.30859.25
110110mm dia pvc pipes for septic tank & IC connection
111Estimate for ELECTRICAL Recessed wiring to light point / first light of group control/ call bell point/ exhaust fan point /wall fan point with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVC conduit with 6 Amp, 250 V clip in type switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size , with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq.) (Make of modular box,cover,switch & socket-Legrand Myrios/schneider Zencelo/Eq.)With 10years warenty. (Group C)
112Recessed wiring to secondary light point looped from primary light point with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC conduit with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor for running earth including 3 plate ISI marked Ceiling rose with all accessories & connection as per direction of Engineer-in-charge. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq.) Average Length: 3 mtr
113Recessed wiring to ceiling fan point with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC conduit with 6Amp 250V Modular Switch,Stepped type Moudular Regulator, Base & Cover with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor for running earth including all accessories & connection as per direction of Engineer in charge. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq.) Group B
114Recessed wiring to Twin control light point with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVC conduit with 6Amp, 250 V clip in type 2way switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size , with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer-in-charge. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq.) Group C
115Recessed wiring for 5 / 6 amp socket outlet with 6Amp, 250 V clip in type modular switch ISI marked mounted on G.I moular box with face plate & cover of suitable size including all accesories and connection on same switch board as per direction of Engineer-in-charge.
116Recessed wiring for 5 / 6 amp socket outlet with 2 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVC conduit with 6Amp, 250 V clip in type switch ISI marked mounted on G.I moular box with face plate & cover of suitable size , with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection on separate board as per direction of Engineer-in-charge.(Make of wire Finolex /Polycab/ Anchor / Havels/Eq) Group C
117Recessed wiring for 2 x 6 amp socket outlet controlled by 2 nos 6Amp, 250 V clip in type switch ISI marked mounted on single G.I moular box with face plate & cover of suitable size including all accesories and connection on separate board as per direction of Engineer-in-charge.
118Recessed wiring for 6 pin 16 amp socket outlet with 16Amp, 250 V clip in type switch ISI marked mounted on G.I moular box with face plate & cover of suitable size including all accesories and connection as per direction of Engineer-in-charge. 25Nos for Stage Light,3Nos For Aquaguard.
119Recessed wiring for A.C/ Power socket outlet with industrial type socket outlet, plug top and metal chained cover in sheet steel enclosure ,20A/32A SP MCB including all accesories and connection as per direction of Engineer-in-charge.
120Recessed wiring to exhaust fan/Wall Fan point with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC conduit with 6Amp 250V Modular Switch, Base & Cover with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor for running earth including all accessories & connection as per direction of Engineer in charge. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq) Group B
121Call bell point with call bell.
122Recessed wiring to submain in 2 x 6 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 25 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 2.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq)
123Recessed wiring to submain in 2 x 4 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq)
124Recessed wiring to submain in 2 x 2.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq)
125Recessed wiring to submain in 2 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq) (For Switch Board Looping)
126DB. Supply and fixing of following way three pole and neutral, sheet steel, MCB distribution, 415 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required wih necessary MCB , RCCB / ISOLATORS as required.Note for MCB- There should be colour indication for tripping On ,Off & Trip/There should be mid trip position for toggles for electrical fault conditions. (A) Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted 12 way SPN Distribution Boards For LDB, CDB & PDB suitable for 440 V, three phase, 4 wire 50 Hz AC Supply complete with bottom detachable plate for interconnections etc as below.Incommer 1 No-40/63A DP MCB (10KA) Outgoings-6-16 A SP MCB 10KA- 10 Nos,(Make-L&T/ Schneider/Hager/Legrand/eq)
127PANEL Supply, installation,testing & commissioning of floor mounting front operated front access extensible type cubicle panel totally enclosed, dust and vermin proof with IP-42 /55 protection with hinged and lockabale doors.CRCA sheets including interconnections,tinned copper crimping lugs, bonding to earth and painting suitable for use at 415 V, 3phase 4 wire 50 Hz system, and to withstand a fault level of 35 KA symmetrical for 1 sec at 415 V complete as per specifications, as required and as below : All switchboards shall have provision for entry of cables from the bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The bus bars shall be insulated with heat shrinkable sleeves.SMC/DMC shrouds and busbar supports shall be used with Indication lamp, C.T , Digital Voltmeter, Digital Ammeter and control fuse etc. complete.MAKE- Legrand / Schneider/ Hager/L&T/SIEMENS/Eq. (A) MAIN PANEL with 100A 4P MCCB 25KA -1 No as incomer,63A DP MCB 10KA 3 Nos.80A 4P Changeover Switch 1 nos, 40A DP MCB 10KA 6Nos with E.C Busbars with 4nos 65KA VSD along with 4nos 32A SP MCB.
128CABLE . Supply & Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of 3.5core 35 sq.mm direct in ground including excavation , sand cushining protective covering and refilling the trench etc. as required.(Make-polycab/RR Kable/Rhino cable/Eq)
129Supply & Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of 4 core 16 sq.mm Aluminium on surface as required.(Make-polycab/RR Kable/Rhino cable/Eq)
130END TERMINATION Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required. (A) 3.5C x 35 sq.mm
131(B) 4C x 16 sq.mm
132EARTHING Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc with charcoal and salt as required.
133Supplying and laying 25 mm x 6 mm CU earth strip ISI marked at 0.5 meter below ground level as strip earth electrode including soldering etc. as required.
134Supplying and laying 25 mm x 6 mm CU earth strip ISI marked on surface or in recess for connection etc as required.
135Providing and fixing 8 SWG CU wire on surface or in recess for loop earthing as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57943796
AUTHORITY Local Bodies
TENDER VALUE 1.22 Crore
LAST DATE 20-10-2026
Authority
Authority Name Municipal Bodies
Work Description Tender for Construction Of Market Complex Building Near Critical Health Care Centre, Pattamundai Municipality
Basic Detail
Tender No PM_02/2026-27
Bidding Type Tender
Location
City Kendrapara
State Odisha
Key Dates
Publish Date 09 Oct 2026
Submission Date 20 Oct 2026
Open Date 22 Oct 2026
Finance
Tender Value 1.22 Crore
Tender Fee 10000
EMD 1.22 Lakhs
Exemption Available
Document List
b6b7365b-f8ea-4094-a127-a9bea37364b1.html
BOQ_613139.xls
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Oct 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

b6b7365b-f8ea-4094-a127-a9bea37364b1.html

xls

BOQ_613139.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender