Tender For Construction Of Phc Building At Iphs Paunskuli Under Basta Block In The District Of Balasore For 2026-27.
Tender Value
1.19 Crore
Estimated cost
Bid Submission
21 Oct 2026
0 days left
EMD
1.19 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Baleshwar → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Phc Building At Iphs Paunskuli Under Basta Block In The District Of Balasore For 2026-27.
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling brickwork, stone nasonry in clay under 3meter height including stacking the useful material for reuse and removing the debris within 50 meter lead etc. complete as per direction of E.I.C. |
| 2 | Dismantling & removing R.C.C. Columns, beams,slab, staircase landing lintels includingstacking the useful material for reuse and removing the debris within 50 meter lead etc. complete as per direction of E.I.C. |
| 3 | Dismantling G.C.I., or A.C. sheet roofing after carefully removing the bolts and nuts including stacking of the materials for reuse and removing the debris within 50 meter lead etc. complete as per direction of E.I.C. |
| 4 | Dismantling wrought and framed timber in roof frame work of floors after carefully removing the bolts and nuts including stacking of the materials for reuse and removing the debris within 50 meter lead etc. complete as per direction of E.I.C. |
| 5 | Dismantling and removing doors, windows, and ventilaters after carefully removing the bolts and nuts including stacking of the materials for reuse and removing the debris within 50 meter lead. |
| 6 | Dismantling and removing 2.5 cm AS flooring including stacking of the materials for reuse and removing the debris within 50 meter lead including cost of all labour, T&P etc. complete as directed by the Engineer in Charge. |
| 7 | 300 mm dia double under reamed pile foundation 5m deep with RCC M-20 including cost of bore excluding cost of steel. |
| 8 | Earthwork in excavationin of foundation in hard soil including rough dressing and levelling the bed etc. complete as per direction of E.I.C. |
| 9 | Filling foundation and plinth with sand well watered and rammed etc. complete as per direction of E.I.C. |
| 10 | Cement concrete of proportion (1:3:6) in foundation and floors using 4cm size black broken granite stone aggregates of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15cm(6\\") thick to the required level ramming, watering, curing etc. complete including cost and conveyance royality taxes of all materials and labour with T&P required for the work etc. complete i as per direction of the Engineer-in-charge. |
| 11 | Cement concrete (1:2:4) with nominal stone aggregate etc. complete as per direction of E.I.C. |
| 12 | 2.5 cm DPC with Cement concrete (1:2:4) including punning using 12mm size hand broken granite chipps etc. complete as per direction of E.I.C. |
| 13 | Fly ash Brick work (1:6) in foundation including all labour and material etc. complete as per direction of E.I.C. |
| 14 | Fly ash Brick work (1:6) in superstructure including all labour and material etc. complete as per direction of E.I.C. |
| 15 | 1st floor |
| 16 | RCC wok of M-20 grade with 20mm downgraded size hard granite chips including hoisting and laying etc. complete as per direction of E.I.C. Column base |
| 17 | Grade beam |
| 18 | Column GF |
| 19 | Column 1st floor |
| 20 | Lintel GF |
| 21 | Chajja |
| 22 | Wall beam |
| 23 | 1st floor |
| 24 | Roof slab |
| 25 | Staircase(GF) |
| 26 | Labour for cutting,bending, shifting to site,tying and placing in position HYSD Bar etc. complete as per direction of E.I.C..(in Ground Floor) |
| 27 | 1st floor |
| 28 | 12mm thick Cement plaster (1:4) over brickwork with neat Cement punning for skirting including curing etc. complete as per direction of E.I.C. |
| 29 | 12mm thick Cement plaster (1:6) for brickwork including curing etc. complete as per direction of E.I.C. |
| 30 | 1st floor |
| 31 | 16mm thick cement plaster in C.M (1:6) including all labour and material etc. complete as per direction of E.I.C. |
| 32 | 1st floor |
| 33 | A/R-P 109/item No.26:6mm thick Cement plaster (1:4) finished smooth per 1 Sqm. including curing etc. complete. |
| 34 | 1st floor |
| 35 | 20mm thick Cement plaster (1:4) over roof slab including curing etc. complete as per direction of E.I.C. |
| 36 | 2.5 cm thick grading concrete (1:2:2) on Roof slab with 6 mm size hard broken granite chips on new works etc. complete as per direction of E.I.C. |
| 37 | Supplying fitting and fixing of Chequerred tiles in floors in cement mortar |
| 38 | Fixing of black granite tiles(above .1 upto .4mm) in floors treads or stepps and landing on 25mm thick bed of Cement mortar 1:1 ( 1 Cement : 1 sand ) jointed with neat Cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete excluding cost of tiles or stones. |
| 39 | Other building item no.1(b) of /S/R-2012:Fixing of vetrified tiles in floors of Size 600x600mm of approved make coformaing to I.S:13755 laid on on 25mm thick bed of Cement mortar 1:4 ( 1 Cement : 4 sand ) and filling joint with white Cement of approved quality in slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of tiles or stones. ( For new work) |
| 40 | A/R-P 132/item No.2:Dressed seasoned salwood work framed and fixed in trusses,purlins, door, window, ventilaters and beams. |
| 41 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 42 | 1st floor |
| 43 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and faceveneers on both faces of shutters. |
| 44 | Providing anf fixing factory made UPVC white colour casement/ casement cum fixed glazed windows Note: For UPVC frame ,sash and mullion extruded profiles minus 5% tolerence in dimension i.e, in depth casement window single panel with s.s friction hinges (300x19x1.9mm )made of small series frame etc complete. |
| 45 | Painting two coats over wood and iron work with approved Enamel paint over a coat of primming, including cost and conveyance of all materials to site, and all labour charges complete as per direction of E.I.C. |
| 46 | 1st floor |
| 47 | S/R-2012/item no. 2:- Finishing wall surfaces with Acrylic wall putty (Water based) of approved make and finished smooth and even surfaces to receive painting including cost of all materials taxes, labour T&P etc. |
| 48 | Wall painting two coats with 100% Acrylic emulsion paint (1st quality) weather seal coat exterior grade of approved make & shade manufactured by reputed manufacturer like NEROLAC / ASIAN / BERGER / DULOX or equivalent to make an even finished surface over a coat of primer with water bond cement primer in all heights with all scaffolding and staging charges including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete. |
| 49 | 1st floor |
| 50 | Distempering 2-coat to walls with distemper of approved shade on old/new work to give on even shade including cost of distemper over one coat of primer |
| 51 | 1st floor |
| 52 | A/R-2006 , page no- 244, item no-11 .Supplying fitting and fixing of stainless steel of 304 grade in hand railing using 50mm dia. Of 2mm thick circular pipe with balustrade of size 32mmx32mmx2mm @ 0.90mtr C/C and stainless square pipe of size 32mmx32mmx2mm in 3 rows in staircase as per approved design and specification etc all completed. Ground Floor |
| 53 | B) PH works Supplying all materials, labour T&P and providing c.c (1:3:6) using 4cm h.g. metal including watering, curing, coveyance of all materials to worksite payment of royalty, taxes etc. all complete as per specification and direction of E.I.C. |
| 54 | Supplying all materials, labour T&P and fixing Ceramic Tiles in floors on 25mm thick bed of cement mortar (1:1) joined with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per specification and direction of Engineer-in-charge. |
| 55 | Supplying all materials, labour T&P and fixing porcelain glazed tiles in dados skirting, on 12mm thick C.P. (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of Engineer-in-Charge |
| 56 | Factory made FRP(alternately called GRP) door frame of size 75mmx100mm fabricated using E-glass Chopped Strand Mat (CSM) U.V stabilised Inopthalic Gelcoat and impregnated with Inopthalic resin. The thickness of the GRP skins shall not be less than 2.00mm. The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The GRP frame shall be provided with wooden reinforcement on six locations for high screw holding capacity for for fixing metallic hold fast and shall be consolidated by filling with medium density foam/plaster of paris with fibre reinforcement, Six numbers of 260mm x 25mm x 5mm size 'S' shaped M.S flat hold fast shall be provided with the frame. The material and process for manufacturing the door frames shall conform to RV-TIFAC composites Design Centre's standards and specifications. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the E.I.C |
| 57 | Factory made single leaf rigid FRP(alternately called GRP) sandwich composite door shutter of 32mm thick laminated with two GRP skins with wood grain finish fabricated using UV-stabilised Isopthalic Gel coat and one layer of 450 gsm E-glass Chopped Strand Mat (CSM) impregnated with orthopthalic polyester resin. The thickness of the skins shall not be less than 1.50mm Expanded Polystyrene(EPS) structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material. Wooden reinforcements made of seasoned sal wood block of cross section not less than 28mmx32mm and also necessary sal wood reinforcements for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, the sal wood reinforcements and the skins. The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters tested in conformation to IS: 4020-1998. The finish of door shutter will be plain colour white/ Ivory/ Beige/Light grey/ Mahogany/Teak wood or any other colour using high quality pigments. Three heavy weight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. |
| 58 | Supplying all materials, labour, T&P and fixing water closet, squatting pan (Indian type W.C. pan/Orissa Pattern Squatting pan) duly embedded in c.c.(1:5:10) using 4 cm h.g. Metal all complete as per direction of E.I.C.- 580x440mm Orissa Pan.(Cerra/ Parry ware/ Hindware) |
| 59 | Supplying all materials, labour T&P and fixing Wash Down Water Closet(European type W.C. pan) with Integral ‘S’ or ‘P’ trap to the floor with wooden plug and C.P.screws including jointing the trap with soil pipe in C.M.(1:1) etc. all complete as per specification & direction of E.I.C-- E.W.C. with ‘S’ trap Plain(Cerra/ Parry ware/ Hindware) |
| 60 | Supplying all materials, labour, T&P fitting and fixing Plastic Seat and cover for E.W.C. with chromium plated brass hinges and rubber buffers all complete as perr specification and direction of E.I.C.(/Cerra/ Parrywear/ Hindware) |
| 61 | Supplying all materials, labour T&P and fitting & fixing SWR ventilating pipes and fittings of the following O.D conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method as per manufacturer’s specification, testing, e.w. in excavation in all kinds of soil and refilling of trenches as per direction of E.I.C.- 110 mm dia PVC SWR Pipes |
| 62 | 110 mm dia PVC SWR P’ Trap |
| 63 | 110 mm dia PVC SWR Door Cross Tee |
| 64 | 110 mm dia PVC SWR DoorTee |
| 65 | 110 mm dia PVC SWR Door Bend |
| 66 | 110 mm dia PVC SWR Plain Bend |
| 67 | 110 mm dia PVC SWR Plain Tee |
| 68 | 110 mm dia PVC SWR Offset |
| 69 | 110 mm dia PVC SWR Cowl |
| 70 | 125 mm dia C.P.grating |
| 71 | 75 mm dia PVC SWR Pipes |
| 72 | 75 mm dia PVC SWR Plain Bend |
| 73 | 75 mm dia PVC SWR Door Bend |
| 74 | 110x75 mm dia PVC SWR R/S |
| 75 | Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with C.I/M.S brackets painted white including holes in walls and making good the damages etc. all complete as per P.H specification and direction of E.I.C.- 550mm x 400mm WHB with all Fittings with C.P. Waste, PVC Waste Pipe & Connection Pipe. (Cerra/ Parry ware/ Hindware) |
| 76 | 32mm Dia Bottle Trap -(Cerra-F-8060301) |
| 77 | Wall mounted 600 mm long hand rail (Cerra-Cat No-82210106) |
| 78 | Wall mounted hinged hand rail 750x100 mm long(Cerra-Cat No-82210108) |
| 79 | Supplying all materials, labour T&P and fixing pedestal for wash basin complete recessed at the back for the reception of pipe and fitting etc. all complete as per specification and direction of E.I.C. (Parrywear/Cerra/Hindware) |
| 80 | Supplying all materials, labour T&P and fixing mirror of superior glass mounted on 6mm thick plywood sheet and fixed to wooden plugs with C.P screws and washers complete as per P.H specification and direction of E.I.C.- 600mm x 450mm B.E. Mirror (fixed type) |
| 81 | Supplying all materials, labour T&P and fixing standard size C.P. towel rail / ring complete with c.p. brass brackets fixed to wooden plugs with c.p screws as per P.H specification and direction of E.I.C.- 20 mm x 600 mm long C.P Towel rail |
| 82 | C.P. Towel Ring (St.) |
| 83 | Supplying all , labour T&P and fitting, fixing of standard size Glass shelf with CP brass bracket and guard rails complete fixed to wooden plugs with CP screw as per specification and direction of E.I.C- 450x125mm size Plate Acrylic Shelf |
| 84 | Supplying all materials, labour T&P and fixing standard size C.P. soap holder complete with c.p brass brackets fixed to wooden plugs with cp screws as per PH specification and direction of E.I.C- C.P.Soap Holder. |
| 85 | Supplying all labour, T&P, materials & fixing wash Kitchen sink with M.S brackets painted white including holes in walls and making good the damages etc. all complete as per P.H specification and direction of E.I.C. -- 600mm x 450mm x 200mm Stainless Steel sink.[Including C.P. Waste & PVC Waste Pipe] |
| 86 | Supplying all labour, T&P, materials & fixing wash Porcelain sink with M.S brackets painted white including holes in walls and making good the damages etc. all complete as per P.H specification and direction of E.I.C. -- 600mm x 450mm x 200mm Porcelain sink.[Including C.P. Waste & PVC Waste Pipe] |
| 87 | Supplying all materials, labour T&P and cutting holes through brick/stone masonary walls for taking PVC pipes and fittings including making good the damages etc. all complete as per P.H. specification and direction of E.I.C. - 250 mm thick wall |
| 88 | Earth work in all kinds of soil in excavation of foundation trenches within 50 m initial lead including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding o.30 in depth and as per direction of E.I.C .- Initial lift up to 1.50m |
| 89 | 2nd depth upt 3.00 mtr |
| 90 | Supplying all materials, labour T&P and filling in F&P with river sand well watered and rammed including conveyance of all materials to worksite payment of royalty, taxes etc. all complete as per direction of E.I.C. |
| 91 | Supplying all materials, labour T&P and providing c.c (1:3:6) using 4cm h.g. metal including watering, curing, coveyance of all materials to worksite payment of royalty, taxes etc. all complete as per specification and direction of E.I.C. |
| 92 | Supplying all materials, labour T&P and providing c.c (1:1.5:3) using 12 mm h.g. chips including watering, curing, coveyance of all materials to worksite payment of royalty, taxes etc. all complete as per specification and direction of E.I.C. |
| 93 | Supplying all materials, labour, T&P and providing brick work with Fly Ash bricks 25cmx12cmx8cm size having cs. not less than 75kg / cm2 with dimensional tolerance ± 8% in including watering,curing conveyance of all materials to worksite, payment of royalty taxes etc. all complete as per specification and direction of EIC. -- In Foundation & Plinth in CM (1:4) |
| 94 | Supplying all materials, labour, T &P and providing C.C (1:1.5:3 ) using 12mm h.g. chips for R.C.C. works including hoisting, laying, watering, curing, conveyance of all materials to worksite, curing, conveyance of all materials to worksite, payment of royalty, taxes etc, all complete as per specification and direction of E.I.C. |
| 95 | Supplying all materials, labour, T&P and providing M.S. reinforcement for R.C.C. works including cutting, bending, binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite etc. complete as per directio n of E.I.C. |
| 96 | Supplying all materials, labour, T&P and providing rigid & smooth centering & shuttering for R.C.C.works including false work and dismantling them after casting including conveyance of all material, to worksite, payment of royalty, taxes etc. all complete as per direction of E..I.C.- R.C.C.Slab |
| 97 | Supplying all materials, labour, T&P and providing cement plaster on brick/stone work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per specification and direction of E.I.C.-- 12mm thick C.P with C.M. (1:4) |
| 98 | 20mm thick C.P with C.M. (1:3) |
| 99 | Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per specification and direction of E.I.C. |
| 100 | Supplying all materials, labour, T&P and providing cement flush pointing to brick masonary (1:3) including watering, curing conveyance of all materials to work site, payment of royality, taxes etc. all complete as per direction of E.I.C. |
| 101 | Supplying all labour, materials T&P and fixing of R.C.C. Baffle wall pre-cast with C.C. (1:1.5:3) using 12 mm b.h.g. chips and fitted to septic tank as per P.H. Specification and direction of E.I.C. |
| 102 | Supplying all materials, labour, T&P and providing PVC Tee inside the septic tank including cutting holes and duly embeded in P.C.C(1:3:6) using 12mm size HG chips fitted and fixed in position and mending good the damages etc all complete as per P.H specification and direction of the E.I.C.- 110mm x110mm x110mm PVC Tee |
| 103 | 160mm x 160mm x 160mm PVC Tee |
| 104 | Supplying all materials, labour, T&P and providing pre-cast R.C.C. Manhole cover with C.C. ( 1:1.5:3) of 12 MM h. g. chips including conveyance of all materials to site after payment of royality and taxes etc.all complete as per PH.Specification and direction of Engineer-in-charge. |
| 105 | Supplying all labour, materials T&P and fixing of M.S.Step iron in 12mm dia M.S. Steel Bar and fixing into walls of septic tank duly embeded in C.C (1:3:6) all complete as per P.H. Specification and direction of E.I.C. |
| 106 | Filling F&P with excavated materials, including watering and ramming as per direction of E.I.C. |
| 107 | Supplying all materials, labour T&P and costructing gully trap chamber of the following inside size with 8cm thick R.C.C. precast cover slab in c.c. (1:1 1.5:3) using 12 mm size h.g. chips foundation concrete (1:3:6) using 40 mm size h.g. metal on bed and arround trap Fly Ash brick work in c.m. (1:6) in F&P and inside 12mm thick c.p (1:3) finished with a floating coat of neat cement including fixing 100mm size H.C.I gully trap and grating etc. all complete as per approved drawing, specification and direction of E.I.C.- Inside size 250mm x 250mm gully trap Chamber |
| 108 | Supplying all materials, labour T&P and constructing Inspection chamber of the following sizes with c.c (1:3:6) using 40mm size h.g. metal on bed, Ist class Fly Ash brickwork in c.m (1:6), moulding and shaping the channel inside and benching with c.c. (1:11/2:3) using 12mm size h.g. chips 12mm thick c.p. (1:3) with punning to inside cement flush pointing (1:3) to outside R.C.C. cover slab in c.c. (1:11/2:3) using 12 mm size h.g. chips with R.C.C. m.h. cover, e.w. in excavation in all kinds of soil and refilling the cavity arround the chamber including watering, curing, conveyance of all materials to site payment of royalty, taxes etc. all complete as per approved specification and direction of the E.I.C.-- Inside size 760mm x 760mm x 460mm I.C. |
| 109 | Supplying all materials, labour T&P and constructing Man hole chamber of the following sizes with c.c. ( 1:3:6) using 40 mm size h.g. metal on bed Ist class Fly Ash brick work in c.m. (1:6) moulding and shaping the channel inside and benching with c.c (1:11/2:3) using 12mm size h.g. chips, 12 mm thick c.p (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C. cover slab in c.c (1:11/23) using 12 mm size h.g. chips with R.C.C m.h. cover, e.w in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to site payment of royalty, taxes etc. all complete as per approved specification and direction of the E.I.C.-- Inside size 910mm x 910 mm x 750 mm |
| 110 | Inside size 910mm x 910 mm x 910 mm |
| 111 | Supplying all materials, labour, T&P and laying 110 mm dia SWR pipes of the following O.D conforming to IS No. 13592 and aligning to requisite gradient inside the trench encasing all round of the pipe with c.c (1:3:6) using 4 CM size h.g. metal and CC(1:3:6) with 4CM size h.g. metal in the bed of the trench including lowering the pipes to the bed of the trench, earth excavation in trenches in all kinds of soil, refilling the same in layer of 0.3 mtrs with watering and ramming, removing of surplus earth, testing of sewerage line including use of T&P as per PH Specification and direction of E.I.C.- 110 mm dia PVC SWR Pipe Sewerage line with all round encasing (conforming to IS No. 13592) |
| 112 | 160 mm dia PVC SWR Pipe Sewerage line with all round encasing (conforming to IS No. 13592) |
| 113 | Supplying all materials, labour T&P and constructing soak way pit of the following sizes with dry brick walling form bottom up to invert of inlet pipe and 1st class Fly Ash brickwork in c.m(1:6) for the remaining height at top, 12 mm thick c.p(1:4) inside and outside over masonary brickwork gravel packing in the rear of well steining R.C.C. cover slab in c.c (1:11/2:3) using 12mm size h.g. chips fitted with iron lifting handles including e.w. in open well excavation in stoney earth and refilling the cavity around the pit & painting the iron works, watering , curing, conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per approved drawing, specification and direction of E.I.C.-1.20mtrs.dia x 2.0mtr.deep soak way pit |
| 114 | 1.40mtrs.dia x 2.0mtr.deep soak way pit |
| 115 | 1.00mtrs.dia x 2.0mtr.deep soak way pit |
| 116 | Supplying all materials labour, T&P and constructing soak way pit of the following sizes with precast RCC rings joined loose gravel backing in the rear of well staining, precast RCC cover slab in c.c. (1:2:4) USING 2mm size hg chips fitted with iron lifting handles including e. w. in open well excavation in all kinds of soil and refilling the cavity around the pit and painting the iron works watering, curing, conveyance of all materials to work site payment of royalty, taxes etc. all complete as per approved drawing, specification and direction of EIC.0.90m dia x 2.00m deep RCC Ring Pit |
| 117 | Supplying all materials, labour, T&P and fixing rotational moulded polyethylene cylindrical vertical waterstorage tank confirming to IS 12701- 1996 including cutting hole through the tank and fixing MS tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting the tank and placing the tank to the required position including all complete as per specification and direction of EIC.(including cost of FG Over Head Tank) ]- 2000 Ltrs. Capacity F.G.Over Head Tank. (1st floor) |
| 118 | Supplying all materials, labour, T&P and Construction of masonary stagging with providing 1st class Fly Ash brick work in c.m, (1:6) of 0.46m. height in staging and in circular protection wall to support the tank in roof of ground floor using 25cm x 12cm x 8cm size Fly Ash bricks having crushing strength not less than 75 kg/cm2 12mm thick c.p.(1:4) over brick work, R.C.C. Slab of size 1.64mtr xl.64mtr x0.l0mtr thick, R.C.C. beam of size 0.25m X 0.30m and 2.60m average length in c.c.(1:1.5:3) using 12mm size h.g. chips including centering and shuttering, watering, curing conveyance of all materials to work site etc. all complete as per specification and direction of E.I.C - For 2000 Ltr. Capacity Over Head Tank(1st floor) |
| 119 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor PVC Pipes conforming to ASTM-D-1785/89(sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor testing all complete as per specification and direction of E.I.C - 20 mm dia PVC (ASTM) Pipe [Internal] |
| 120 | 25 mm dia PVC (ASTM) Pipe [Internal] |
| 121 | 25 mm dia PVC (ASTM) Pipe [External] |
| 122 | 32 mm dia PVC (ASTM) Pipe [External] |
| 123 | 40 mm dia PVC (ASTM) Pipe [External] |
| 124 | 32mm dia HDPE Pipe [Inside Tw] |
| 125 | 32mm dia HDPE Pipe [External Including Earth Work] |
| 126 | 20mm dia HDPE Pipe [External] |
| 127 | Supplying all materials, labour, T&P and cutting holes through brick/stone masonary works including making good the damages in c.m. (1:4) for taking P.V.C. pipes & fittings etc. all complete as per P.H. specification and direction of E.I.C. |
| 128 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages as per direction of the E.I.C. |
| 129 | Supplying all materials, labour, T&P and fitting & fixing brass /C.P. fittings of the following nominal bore with supply of all jointing materials etc. complete as per P.H. specification and direction of E.I.C.- 15 mm dia C .P S.B. Bib Cock [Jaquar] |
| 130 | 15 mm dia C .P L.B. Bib Cock[Jaquar] |
| 131 | 15 mm dia C .P Angle Stop Cock[Jaquar] |
| 132 | 20mm dia C .P Conceal Stop Cock[Jaquar] |
| 133 | 15 mm dia C .P Pillar Cock[Jaquar] |
| 134 | 15 mm dia C .P Pillar Cock Elbow Action[Jaquar] |
| 135 | 15 mm dia C .P Two Way Bib Cock [Jaquar] |
| 136 | 15 mm dia C .P Health Facuet[Jaquar] |
| 137 | 15 mm dia C .P Elbow Action Bib Cock[Jaquar] |
| 138 | 15 mm dia C .P Extension Piece |
| 139 | 25 mm dia PVC Ball Valve (Metal Ball) [Good Quality] |
| 140 | 32 mm dia PVC Ball Valve (Metal Ball) [Good Quality] |
| 141 | Supplying all materials, labour, T&P and fitting and fixing C.P. shower with 15 mm or 20 mm inlet with C. P. shower arm including polishing all complete as per P.H. specification and direction of E.I.C. |
| 142 | Supplying all materials, labour T&P and fitting & fixing 10 Litres capacity low level cistern with a pair of cast iron of m.s. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float, c.p. brass handle, unions and couplings for connection with inlet, outlet and overflow pipe. 32 mm C.P flush bend 15mm PVC inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting inlet pipe with supply main etc. all complete as per specification and direction of E.I.C (Neycer/Cerra/ Parry ware/ Hindware) |
| 143 | Sinking of 125x100mm dia tube well through Hand boring Method Supplying all materials, labour, T&P and setting up boring equipments including irrection of suitable stagging for installation of the required size of tube-well. Dismantling & removing the same after completion of the work including transportation of boring equipments clearing & leveling the site, excavation of mud pit channels etc., leveling of site all complete as per direction of E.I.C(Labour) |
| 144 | Supplying all labour, T&P & transportation of boring pipes, top casing, grouping pipes, PVC pipes and fitting, PVC well screens, cement, betonite etc. including loading and unloading etc. complete as per direction of the E.I.C.(Labour) |
| 145 | Supplying all labour, T&P and drilling pilot bore not less than 102mm dia without casing pipes in all kinds of soil and rocks for the following depths excluding supply of necessary boring pipes including supply of necessary cutting equipments extra sockets etc.and withdrawing the boring pipes washing & keeping the bore clear for logging if required all complete as per the direction of EIC-- Pilot bore 100mm dia (00 mtr. to 360 mtr.) |
| 146 | Supplying all labour, T&P & reaming the pilot bore to the following sizes and depths without casing pipes including withdrawing the boring pipes, washing the bore by means of pipe cylinder etc. all complete as per direction of E.I.C. -100 mm ot 150 mm dia( 00 mtr to 360 mtr) |
| 147 | 150 mm to 200 mm dia( 00 mtr to 360 mtr) |
| 148 | 200 mm to 250 mm dia( 00 mtr to 360 mtr) |
| 149 | Supplying all labour, Tools and plant and lowering the 300mm dia top casing pipe into position and removing the same after use as per the direction of Engineer-in-charge. |
| 150 | Supplying all labour, T&P and jointing materials and lowering the PVC casing pipes fitting and well screens in position including fitting of centralizer cutter plugs and washing the bore as per the direction of E.I.C.(Including cost of Materials) 125 mm dia PVC Pipe (Schedule-80) |
| 151 | 100 mm dia PVC Pipe (Schedule-80) |
| 152 | 100 mm dia PVC strainer |
| 153 | 125x100 mm dia PVC R/S |
| 154 | 100 mm dia C.I. Plug Cutter |
| 155 | Lowering of 125mm/100mm dia PVC Pipe |
| 156 | Supplying all labour, T & P and packing the bore with washed gravel ( size-P-6) around the pipes in good quality including cost of gravel etc. all complete as per direction of Engineer-in-Charge- |
| 157 | Cost of Gravel |
| 158 | Supplying all labour, T&P materials and providing sanitary sealing by cement slurry grouting around the uppermost 3.00 mtrs. of 125 mm dia PVC casing pipe . including cost of cement all complete as per direction of E.I.C (including cost of 2 bags of Cement) |
| 159 | Cleaning the developing the tube well using compressor continuously to get clear and adequate discharge from the tube well including the supply and use of all necessary equipment and labour as per direction of E.I.C(Labour Charges) |
| 160 | Supplying all labour, T&P and materials for fitting and fixing of India Mark-II Deep well Hand Pump with cast Iron cylinder, 12mm/16mm dia B.S. Connecting rod, 32mm dia G.I.Pipe of required lengths with supply of extra socket of approved make all complete including carriage, coveyance as per direction of Engineer-in-charge. |
| 161 | Supplying all labour, T&P and materials for Construction of Masonary Platform for India Mark-II Hand Pump as per I.S. Specification of 1.85 mtr Outside with Cement Concrete (1:2:4) with 12mm size hard granite C.B. chips etc. all complete including 760mmx760mmx400mm deep cement concrete embeded around the bore well pipe as per direction of Engineer-in-Charge. |
| 162 | Supplying all materials, labour, T&P and construction of 100mm wide waste water drain for India Mark-II Hand Pump platform as per UNICEF design and specification with C.C (1:2;4) using 12mm size hard granite crusher broken chips etc. all complete as per direction of Engineer-in-Charge. |
| 163 | Supplying of ISI Mark 1.00 HP Single Phase Vertical Submersible Pump Set with Discharge of 1800-2200 liter/hour and a head of 45-60 mtr of reputed make like KSB/Texmo & Equivalent including all cost, conveyance and taxes etc. all complete as per direction of Engineer-in-charage. |
| 164 | Supplying all labour, T&P and fitting and fixing of 1.00 HP Single phase vertical Submersible Pump Set with commissioning and testing, Electrification etc. all complete as per direction of EIC |
| 165 | Supplying and fitting and fixing of ISI Mark DOL Starter of reputed make like BCH or Equivalent for 1.00 HP Single Phase Submersible Pump including all cost, conveyance and taxes etc. all complete as per direction of Engineer-in-charge. |
| 166 | Supplying and fitting and fixing of three core flat cable (2.5mm2) of ISI Make of reputed company line BCH/Finolex or Equivalent and connecting the pump and starter including all cost, conveyance and taxes etc. all complete as per direction of Engineer-in-charge. |
| 167 | Supplying and fitting & fixing of Plastic rope, M.S. Well Cover, M.S. Clamp, Stainless Steel Short piece, Bend & Socket including all const, conveyance and taxes etc. all complete as per direction of engineer-in-charge. |
| 168 | C) EI Works Recessed wiring to light point with 1.5 sq.mm FR PVC insulatedsingle core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5Amp, 250 V piano type modular switch ISI marked and ceiling rose ISI marked mounted on MS box having front Modular base & cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. (Make of wire: Finolex/ L&T / Anchor / Havels /HPL / V Guard/KEI/ Greatwhite/Polycab) (Make of Switch & Socket: Anchor / Cona/ Greatwhite/ Havells/ HPL/ Preeti) -do- Group A |
| 169 | -do- Group B |
| 170 | -do- Group C |
| 171 | Recessed wiring to Fan Point in... -do- Group B |
| 172 | Recessed wiring to Call Bell Point in... -do- Group C |
| 173 | Recessed wiring to Exhaust Fan Point in….. -do- Group C |
| 174 | S/F of fan hook 'S' type made of 16 mm MS rod for fixing in the Existing RCC Roof. |
| 175 | S/F of Angle holder replacing Ceilling Rose (Make : Anchor / Cona/ Greatwhite/ Havells/ HPL/ Preeti) |
| 176 | S/F of 5A. Modular Switch & 5A. Modular Socket outlet of ISI marked on existing board (Make of Switch & Socket: Anchor / Cona/ Greatwhite/ Havells/ HPL/ Preeti) |
| 177 | S/F of extension board of 6 modular Metal box with modular base & cover in recess including providing and fixing of 2 nos of 3pin 5/6amp modular socket out let & 2 nos of 5/6 amp piano type modular switch, connection, painting etc as required. (Make of Switch & Socket: Anchor / Cona/ Greatwhite/ Havells/ HPL/ Preeti) |
| 178 | S/F of Power point with 4 modular metal box with modular base & cover in recess including providing and fixing of 5 pin 15/16 amp. piano type Modular switch & Socket, connection, painting etc as required (Make of Switch & Socket: Anchor / Cona/ Greatwhite/ Havells/ HPL/ Preeti) |
| 179 | S/F of Power point with 4 modular & 2 modular metal box with modular base & cover in recess including providing and fixing of 5 pin 15/16 amp. piano type Modular switch & Socket & Mini DP MCB, connection, painting etc as required for AC. (Make of Switch & Socket: Anchor / Cona/ Greatwhite/ Havells/ HPL/ Preeti)(AC 3 Nos & Gyser 4 Nos) |
| 180 | S/F of computer board consisting of 3 nos of 5amp modular plug and modular switch & 1 no of Mini MCB complete with wiring on 12 modular M.S. box with modular cover. (Make of Switch & Socket: Anchor / Cona/ Greatwhite/ Havells/ HPL/ Preeti) |
| 181 | S/F of 1 no of 5 pin 15/16 amp. Socket , 1 no of switch & 1 no of 15/16A top with modular mini MCB, in 6 modular box with cover with connection, painting etc as required for Inverter connection. (Make : Anchor / Cona/ Greatwhite/ Havells/ Legrand/ L&T) |
| 182 | S/F of 18 SWG Modular metal box of following sizes (Nominal size) in recess with suitable size of Modular base & cover in front including cutting the wall and making good the same in case of recessed conduit as required. 2 Modular box with base & cover |
| 183 | 4 Modular box with base & cover |
| 184 | 6 Modular box with base & cover |
| 185 | 8 Modular box with base & cover |
| 186 | 12 Modular box with base & cover |
| 187 | Wiring for circuit / sub-main wiring along with earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20mm dia non metalic heavy duty flexible conduit 1.6mm in recessed PVC conduit as required (Make of wire: Finolex/ L&T / Anchor / Havels /HPL / V Guard/ KEI/ Greatwhite/ Polycab) 2x1.5+1x1.5 (1.8.1) |
| 188 | 2x2.5+1x1.5 (1.8.2) |
| 189 | 2x4+1x1.5 (1.8.3) |
| 190 | 4x6+2x2.5(1:8:10) |
| 191 | Inverter wiring (1x2.5smm) Copper wire (1.19.11a) |
| 192 | S/F of 'B/C/D' series SP MCB of 5 - 32A amp rating (As per direction of engineer in charge) 240Volt for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required single pole (SP) (2.6.1) (Make : Anchor / Cona/ Greatwhite/ Havells/ Legrand/ L&T) |
| 193 | S/F of 'B/C/D' series DP MCB of 5 - 32A amp rating (As per direction of engineer in charge) 240Volt for lighting and other loads in the 2 Way double door MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required (2.6.2a)+(2.3.1b) (Make : Anchor / Cona/ Greatwhite/ Havells/ Legrand/ L&T) |
| 194 | S/F of 'B/C/D' series TPN MCB of 63A amp rating (As per direction of engineer in charge) 440Volt for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required without MCB box(2.6.4) (Make : Anchor / Cona/ Greatwhite/ Havells/ Legrand/ L&T) |
| 195 | Supply, Installation testing & commissioning of Main Switches (IS13940 part 3/1993) of following coopacity on existing surface/wall mounting & complete with H.R.C fuse links, inter connections earthing etc as required as per direction of Engineer Incharge (Make-Seimens/ HPL/Anchor/L&T /Havels/C&S/R. K.) S/F of 6 way (6+18) TPN MCB DB double door (2.5.6). |
| 196 | S/F of G.I.Earth Plate Earthing 600 mm x600mmx6mm with Salt & Charcoal for Earth electrode (3:4)+(3.6) |
| 197 | S/L of 25mm x 6mm G.I. earth strip in ground(3:10) |
| 198 | Supply and fixing of 225mm Exhust fan with all accessories and connections (Make:Usha-Aero Clean Plus DBB/Crompton- Trans Air 12\\" reversiable /Havells-Venti Air DS (HS)/Anchor- Anmol delux R/ Orient-Power Flow DBB/ Pollycab -Fresh on DBB ) |
| 199 | S/F of Call bell/Buzzer(Ding dong type) ISI marked suitable for DC/AC single phase 230 volts complete as required. (1.30) |
| 200 | S/F of 18-25Watt L.E.D Tube light fitting with all accessories and connections ( Make- Crompton/ HPL/ Polycab/ Havells/ / Panasonic/ RR/Crompton ) |
| 201 | SITC of 1200mm Sweep BLDC Ceiling Fan with Aluminium Blades having watage not more than 28 watt & Air Deleivery ≥ 215m3/min. (Replacement warranty will be 4 years) (Make:Usha-Techinix /Crompton- Energion Groove/Havells-Efficiencia Neo) |
| 202 | S/F step type modular fan regulator |
| 203 | Supply and fixing of 400 mm wall fan with all accessories and connections (Make:Usha-Maxx Air Ultra /Crompton- WM Hiflow wave /Havells-Accelro(HS)/Anchor- Altrix HS- OWH /Orient-Wall 43/ Great White - WYNO WF/ Pollycab -Aery HS ) |
| 204 | Supply and fixing of 60 Watt Single LED Street Light Fitting with LED & Electronic driver with all accessories and connections (Make- Crompton/ Phillips/ HPL/ Polycab/ Havells/ Panasonic/ RR/ Orient ) |
| 205 | S/F of 10w Watt LED Bulb (Make- Crompton/ Phillips/ Havells/ Panasonic) |
| 206 | S/F of 1.5TR with 5StarBEE Rating AC Machine, (Make-Hitachi RAS. V518PCDIBT1 / Toshiba-RAS-18G3KCV5SG/Voltas-VOLTAS SAC185INV VECTRA) |
| 207 | S/F of 4KVA Automatic Voltage Stabilizer(90-300V), (Make-Microtech/V-Guard/ Shakti) |
| 208 | S/F of Outdoor Wall Mounting Bracket |
| 209 | S/F of 2000 VA/24V Inverter with 2 nos. 180Ah battery including trolley arrangement (Make: V-Guard/ Microtake/ Luminous) |
| 210 | S/F of 12W LeD Squre (10\\"×10\\") LSDSMN-12W-WW with surface Panel rings (Havels/crompton/philips/panasonic) |
| 211 | Provision of Armoured cable size 3 1/2 x 35sqmm (25) Make: Gloster/ KEI/ Finolex/ Anchor/ Havells/ V-Guard/ HPL/ L&T/ Greatwhite/ Pollycab) |
| 212 | Laying of MV cable above 25sqmm to 120 sqmm in ground (5.1.2) |
| 213 | Laying of MV cable above 25sqmm to 120 sqmm on surface (Horizontally)(5.5.2) |
| 214 | Supply & fixing of 100 A TPN Panel board 1. 100A MCCB (Make- Legrand/Seimens/L&T/C&S/) & 100A kitkat & bus bar2. 32 A TPN MCB (Make- Legrand/Seimens/L&T/C&S/)- 2nos 3. 32A DP MCB (Make- Legrand/Seimens/L&T/C&S/)- 5 nos 4. 100 A 4P Manual changeover (Make- Legrand/Seimens/L&T/C&S/)- 1nos5. Digital Volt meter & Ameter three phase 6. All accesories & Connection (Rating & Danger borad) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 09, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
TodayOct 22, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender