Defence Statutory Bodies & Commissions/Committees Closing in 2 days TDR #57942187

Tender For Repair /Rectification Of Day To Day Complaints Of External Water Supply System Including Ci/Di/Gi Pipe Line Network Sluice Valves, Valve Pit Chambers Including Connected Works In Mh Khadki And Range Hill Areas Under Ge (Mh & Rh) Khadki

Issued by Statutory Bodies & Commissions/Committees · Pune, Maharashtra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
30 Oct 2026
2 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair /Rectification Of Day To Day Complaints Of External Water Supply System Including Ci/Di/Gi Pipe Line Network Sluice Valves, Valve Pit Chambers Including Connected Works In Mh Khadki And Range Hill Areas Under Ge (Mh & Rh) Khadki

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 15-Oct-2026 Corrigendum BOQ 30-Oct-2026

BOQ

Name of Work:- REPAIR /RECTIFICATION OF DAY TO DAY COMPLAINTS OF EXTERNAL WATER SUPPLY SYSTEM INCLUDING CI/DI/GI PIPE LINE NETWORK SLUICE VALVES, VALVE PIT CHAMBERS INCLUDING CONNECTED WORKS IN MH KHADKI AND RANGE HILL AREAS UNDER GE (MH & RH) KHADKI
Sl. No. Item Description
1Labour only for attending the emergency repairs to leakage/damage of GI pipe of 15/20/25/40/50 mm dia either in night or in any holiday, running between west side pump house and MH kirkee and all Range Hills area including carrying out major repairs to the leakage/breakage etc as required to make the system in order / functional and necessary excavation ,returning , filling of soils and removal of water by using pump, cutting and jointing with new fittings as required at site complete all as specified and directed by Engr-in-charge.Note (i) Rate inclusive of earth work by means of JCB machine. (ii) Jointing materials if required will be measured in kg separately under seperate items in this schedule.
2Labour only for attending the emergency repairs to leakage/damage CI/DI pipe of 300/400 mm dia either in night or in any holiday, running between west side pump house and MH kirkee and all Range Hills area including carrying out major repairs to the leakage/breakage etc as required to make the system in order / functional and necessary excavation ,returning , filling of soils and removal of water by using pump, cutting and jointing with new fittings as required at site complete all as specified and directed by Engr-in-charge.Note (i) Rate inclusive of earth work by means of JCB machine. (ii) Jointing materials if required will be measured in kg under seperate items in this schedule.
3All as per item No. 2 but for dia of Pipe 80/ 100/150/200 mm complete all as specified and directed.
4Taking up or taking down old unserviciable damaged / rusted CI/DI Pipe of following dia with connections removal from site complete all as specified and directed :-
5400 mm dia.
6300 mm dia.
7200 mm dia.
8150 mm dia
9100 mm dia.
1080 mm dia.
11Supply, Laying, jointing & testing of Ductile iron (DI), pressure pipes with spigot or socket ends or flange ends, centrifugally cast, class K-9, with cement mortar lining in inner side as per IS:8329/ 2000 (latest revision) and other relevant standards and metallic zinc coating followed by a finishing layer of epoxy paint in outer side, suitable for push on joint (rubber gasket joint) in any length with inside cement mortar lining laid in trenches complete all as specified and directed. of following sizes:- Note : Excavation shall be measured and paid separately.
12(a) 400 mm dia
13(b) 300 mm dia
14(c) 200 mm dia
15(d) 150 mm dia
16(e) 100 mm dia
17(f) 80 mm dia
18Supply and Fixing in repairs cast iron body heavy duty non return valve ISI marked ( NRV) both ends flanged with 2 Nos rubber insertion gasket joints, nuts, bolts & washers of required size & Nos complete of the following bore sizes complete all as specified and directed.
19200 mm dia
20150 mm dia
21100 mm dia
2280 mm dia
23Supply and fixing in repair cast iron air release valve , ISI marked both end flanged with nut bolt washers and rubber gasket confirming IS 4038, installation, testing of following sizes complete all as specified and directed.
24150 mm
25100mm
26Supply and Fix in repairs Cast iron sluice valve with spindle and cast iron hand wheel complying with IS:14846-2000, class PN 1.6 IS with inner working parts brass both ends flanged with 2 Nos rubber insertion gasket joints, nuts, bolts & washers of required size & Nos complete of the following bore sizes complete all as specified and directed. :-
27400 mm dia
28300 mm dia
29250 mm dia
30200 mm dia
31150 mm dia
32100 mm dia
3380 mm dia
34Supply and fixing in repairs cast iron foot ball valve, normax type, ISI marked both end flanged with nut bolt washers and rubber gasket confirming to IS 4038, installation, testing of following sizes complete all as dircted and specified
35200 mm dia
36150 mm dia.
37100 mm dia
3880 mm dia.
39Material and labour in repair for cast iron/MS fitting for connecting pieces one end flanged and other end socket or spigot and bell mouth pieces one end flanged other end tapering as bell mounth, DI Bends tapers, Tees, pieces (Single or double branch) any Type and angle/ radius and straight connecting pieces for DI Pipe of following bore complete all as specified and directed.Note : 1. The rates include transportation, handling and placing in positgion the fittings in proposed loation and alignment to the laying of pipes as ordered.2. The rates also include for cuttings of pipe for insertion of fittings where necessitated in new works.
40Fitting required for size 80 to 150 mm dia
41Fitting required for size 200 to 300 mm dia
42Fitting required for size400mm dia
43Material and Labour for mechanical joint consisting of compression collars made out of Cast Iron, MS Flanges drilled as per IS for pressure rating PN1.6, including MS nuts, bolts, rubber gasket,cleaning the pipe surface,chamfering or cutting the edges of pipes for positioning, jointing and testing for the following size and of pipe material GI/CI/MS, and taking down old unserviceable machanical joint complete all as specified and directed by Engr-in-charge.
44400mm bore
45300mm bore
46200mm bore
47150 mm bore
48100 mm bore
4980 mm bore
50Taking up or taking down steel tubing and connections including cleaning for refixing or removal to store for the following sizes complete all as specified and directed :-
5115 mm dia
5220 mm dia
5325 mm dia
5440 mm dia
5550 mm dia
5680 mm dia
57Relaying only GI tubes any grade in trenches materials obtained from Item No.12 here-in-before after cleaning or rerunning the old screw threads with replacement of unserviceable fittings and fixtures for following size of complete all as specified and directed.
5815 mm dia
5920 mm dia
6025 mm dia
6140 mm dia
6250 mm dia
6380 mm dia
64Supply and laying for galvanised iron tubing medium grade ISI Mark with and including all fittings such as bends, elbows, tees, short pieces, union etc in trenches complete all as specified and directed of following sizes :-.
6515 mm dia
6620 mm dia
6725 mm dia
6840 mm dia
6950 mm dia
7080 mm dia
71Supply and Fix gun metal gate valve ISI Mark with following mm dia with iron wheel head screwed both ends ISI marked fixed to GI pipe including removal of old unserviceable complete all as specified and directed.
7215 mm dia
7320 mm dia
7425 mm dia
7540 mm dia
7650 mm dia
7780 mm dia
78Material and labour for construction of Brick Masonry with sub class B1 bricks Valve Pit, one Brick thick wall in cement mortar 1:4 on 100mm thick PCC 1:4:8 type D2 (40mm graded stone aggregate) in Foundation, Rendering 15 mm thick internally and externally upto 150mm below GL, providing 3.0mm thick MS Sheet Valve Pit Cover, welded with 40X5mm Flat Iron Frame alround including provision of Hinges, Handle and Locking Arrangement and 40 x 40 x 6mm Angle Iron Frame fixed on Top of Valve Pit by means of Holdfast 150mm long, embedded in PCC 1:2:4 type B1 (20mm graded stone aggregate) Block of size 230 x 200 x 100 mm, applying two coats of Anti-corrosive Paint over a coat of Red Oxide Zinc Chrome Primer after preparation of all exposed Steel Surfaces including necessary Earth Work in Soft/Loose Soil and demolition of old unserviceable Valve Pit of following sizes complete all as specified and directed.
791200 x 1200 x 1200 mm (Internal Dimension)
801000 x 1000 x 1000 mm (Internal Dimension)
81900 x 900 x 900 mm (Internal Dimension)
82600 x 600 x 600 mm (Internal Dimension)
83Material and labour for repair of existing Brick Masonry Valve Chamber, with brick work with sub- class 'B' brick in one brick thick wall in cement mortar 1:4 including Rendering of Cement plaster 10 mm thick internally and externally with Cement motor 1:6 complete all as specified and directed.
84Material and labour in repair for brick Masonry Valve Chamber cover of any size and discription with and including MS Sheet Cover 6 mm thick, welded with 40 x 5 mm Flat Iron Frame alround including provision of Hinges, Handle and Locking Arrangement and 40 x 40 x 6 mm Angle Iron Frame fixed on Top of Valve Pit by means of Holdfast 150mm long, embedded in PCC 1:2:4 (20mm graded stone aggregate) Block of any size, applying two coats of Anti-corrosive Paint over a coat of Red Oxide Zinc Chrome Primer after preparation of all exposed Steel Surfaces and complete all as specified and directed.
85Taking down Mechanical actuator held from existing position and refixing the same after servicing in specified location incl checking & laying the supply cable testing complete all as specified and directed by Engineer in Charge
86Supply and Fix MS Pipe conforming to IS : 1239 of sizes 300 mm dia and 8 mm thick laid in trenches/ floor including bend, elbow, and Tee flanges cutting welding and necessary nut nolts required for fixing the pipe in location,including taking down old unserviceable complete all as specified and directed.Note: Cost of pipe are inclusive with BEND TEE Tee equal reducer etc.
87Ditto-- as same as Item No.20 but for 250 mm dia
88Ditto-- as same as Item No. 20 but for 200 mm dia
89Ditto-- as same as Item No. 20 but for 150 mm dia
90Ditto-- as same as Item No.20 but for 100 mm dia
91Ditto-- as same as Item No.20 but for 80 mm dia
92Taking down unserviciable and Material and labour for fabrication/structural work with mild steel sheet angle iron , MS Pipe in any shape or size as indicated framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc..all as directed and including belding/ bracing, painting with one coat of red oxide primer and two coat of black paint (one coat before fixings and one coat of black paint after fixing ) fe-290, Grade E-165, complete all as specified and directed.
93Material and Labour for PCC 1:3:6 ,Type C1, using 20mm graded stone aggragate for foundations, filling and mass concrete complete all as specified and directed.
94Material and labour for cement concrete interlocking tiles 60 mm thick in floor/pavement laid over and including 30 mm thick stone dust/sand cushioning laid dry to profile complete all as specified and directed by Engineer-in-Charge
95Material and Labour for High strength free flowing solid chlorination medium fortified with corosion inhibitors and anti scaling agent for drinking water application. Minimum chlorine strength 55%. OEM claim regarding corosion inhibitors and anti scaling agent content must be ratified by E-in-C branch (Copy of E-in-C branch letter must be submitted to qualify for bid/tender).
96Supply and Fix in repair Ball brass valve, high pressure with polythene float and fly nut complete ISI marked of following size, complete all as specified and dircted by Engineer-in-Charge.
9750 mm bore
9840 mm bore
9925 mm bore
10020 mm bore
10115 mm bore
102Testing of treated water as per norms / standard raw sewage characteristics from Govt approved laboratory complete all as specified and directed by Engineer in charge.Note - Contractor shall collect water sample from treated water tank of STP twice in a month for testing of treated water from Govt approved agency and report shall be submitted to Engineer in charge
103Supply and Fix in repairs following capacity six layer, White in colour, ISI Mark, rotational moulded, polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow pipe etc complete all as specified and directed.
104500 Ltr
1051000 Ltr
1062000 Ltr
107Dismantling the water meter (any make) of size 300mm dia for repairs/ calibration from its position and inserting a flange of same size and length, transporting to civil workshop / Laboratory for replacing the wornout spares and calibration testing from MIDC and transporting back to site, refixing the same on existing position with rubber gaskets, testing for leakages complete all as specified and directed.Note: Test certificate shall be obtained from testing officer of MIDC and submitted to Engr- in -charge.
108Excavating in trenches, not exc. 1.5mtr wide and not exc. 1.5 mtr in depth for laying of pipe line in complete all as specified and directed the following.
109soft / loose soil
110Hard/ dense soil
111Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and directed.
112Removing excavated meterial to a distance n.exc 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57942187
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 30-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair /Rectification Of Day To Day Complaints Of External Water Supply System Including Ci/Di/Gi Pipe Line Network Sluice Valves, Valve Pit Chambers Including Connected Works In Mh Khadki And Range Hill Areas Under Ge (Mh & Rh) Khadki
Basic Detail
Tender No 8897/E8
Bidding Type Tender
Location
City Pune
State Maharashtra
Key Dates
Publish Date 15 Oct 2026
Submission Date 30 Oct 2026
Open Date 01 Jan 0001
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 80000
Exemption Not Available
Document List
bed78448-26a5-4023-9318-cda09c7251f2.html
BOQ_889260.xls
TENDER8897.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 30, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 2 days
Oct 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
html

bed78448-26a5-4023-9318-cda09c7251f2.html

xls

BOQ_889260.xls

pdf

TENDER8897.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender