Tender For Repair/Maint Of Lt Panels Including Apfc Panels, Earthing, Dg Sets And Connected Items Installed At Nimu, Sangam Hill And Nanak Hill At Nimu Mil Stn Under Age (I) Nimu
Tender Value
35 Lakhs
Estimated cost
Bid Submission
29 Oct 2026
19 days left
EMD
70000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Leh → Ladakh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maint Of Lt Panels Including Apfc Panels, Earthing, Dg Sets And Connected Items Installed At Nimu, Sangam Hill And Nanak Hill At Nimu Mil Stn Under Age (I) Nimu
BOQ
| Sl. No. | Item Description |
| 1 | Checking, Inspection, maintanance and servicing complete including replacement of unserviceable spare parts of the DG set (comparising of Engine/ Alternator/ Control panel) of capacity 500 KVA DG Sets at 25 Grndr & Power house for smoth functioning complete all as per manufacturers instructions and all as directed by Engr-in-Charge.(a) Checking of lubricating oil condition (b) Checking engine for oil, water leakage and correcting the same(c) Checking of all the nut bolts of engine and alternator (d) Checking of all belts and adjust the tension properly (e) Cleaning of air filters(f) Checking and readjusting the valve clearance(g) Change of Oil/Fuel filters and engine oil if necessary(h) Checking of starter motor battery and charger(i) Checking of cooling system and fuel system(j) checking of all power cables and AVR connections and mounting bolt tightness of alternator(k) checking the function of AVR general checks (l) Checking of control panel meters and gadgets functioning(m) Checking of all control and safety wirings(n) Checking of flexible coupling of engine and alternator (o) Cleaning of crank case ventilation pipe(p) Checking of injectors and fuel pumpNOTES: (1) Cost of Spares required will be paid and measured separately under item No 1.01 to 1.05 of BOQ(2) Servicing/routine check up carried out through authorised service centre of manufacturer.(3) Make of spare recommendation by auth service centre of manufacturer.Checking of alternator and carbon brushes. |
| 2 | Supply only 'V' belt for water pump |
| 3 | Supply only fuel pipe with banjo bolt at both side |
| 4 | Supply only oil filter element |
| 5 | Supply only air cleaner element (inner and outer) |
| 6 | Supply only fuel filter element (primary and secondary) |
| 7 | All as per Srl item No. 1.00 above but DG Set of capacity 180 KVA complete all as specified and as directed by Engineer-in-Charge. NOTES: (1) Cost of Spares required will be paid and measured separately under item No 2.01 to 2.05 of BOQ(2) Servicing/routine check up carried out through authorised service centre of manufacturer.(3) Make of spare recommendation by auth service centre of manufacturer.Checking of alternator and carbon brushes. |
| 8 | Supply only 'V' belt for water pump |
| 9 | Supply only fuel pipe with banjo bolt at both side |
| 10 | Supply only oil filter element |
| 11 | Supply only air cleaner element (inner and outer) |
| 12 | Supply only fuel filter element (primary and secondary) |
| 13 | All as per Srl item No. 1.00 above but DG Set of capacity 125 KVA complete all as specified and as directed by Engineer-in-Charge. NOTES: (1) Cost of Spares required will be paid and measured separately under item No 3.01 to 3.05 of BOQ(2) Servicing/routine check up carried out through authorised service centre of manufacturer.(3) Make of spare recommendation by auth service centre of manufacturer.Checking of alternator and carbon brushes. |
| 14 | Supply only 'V' belt for water pump |
| 15 | Supply only fuel pipe with banjo bolt at both side |
| 16 | Supply only oil filter element |
| 17 | Supply only air cleaner element (inner and outer) |
| 18 | Supply only fuel filter element (primary and secondary) |
| 19 | All as per Srl item No. 1.00 above but DG Set of capacity 62.5 KVA complete all as specified and as directed by Engineer-in-Charge. NOTES: (1) Cost of Spares required will be paid and measured separately under item No 4.01 to 4.05 of BOQ(2) Servicing/routine check up carried out through authorised service centre of manufacturer.(3) Make of spare recommendation by auth service centre of manufacturer.Checking of alternator and carbon brushes. |
| 20 | Supply only 'V' belt for water pump |
| 21 | Supply only fuel pipe with banjo bolt at both side |
| 22 | Supply only oil filter element |
| 23 | Supply only air cleaner element (inner and outer) |
| 24 | Supply only fuel filter element (primary and secondary) |
| 25 | All as per Srl item No. 1.00 above but DG Set of capacity 40 KVA complete all as specified and as directed by Engineer-in-Charge. NOTES: (1) Cost of Spares required will be paid and measured separately under item No 5.01 to 5.05 of BOQ(2) Servicing/routine check up carried out through authorised service centre of manufacturer.(3) Make of spare recommendation by auth service centre of manufacturer.Checking of alternator and carbon brushes. |
| 26 | Supply only 'V' belt for water pump |
| 27 | Supply only fuel pipe with banjo bolt at both side |
| 28 | Supply only oil filter element |
| 29 | Supply only air cleaner element (inner and outer) |
| 30 | Supply only fuel filter element (primary and secondary) |
| 31 | Supply and replacement of Turbo Charger assy for 500 KVA DG Set complete all as specified and as directed by Engineer-in-Charge. |
| 32 | All as per srl item No. 6.00 here-in-before but for capacity 62.5 KVA DG Set. |
| 33 | All as per srl item No. 6.00 here-in-before but for capacity 40 KVA DG Set. |
| 34 | Supply and replacement of self starter of capacity 500 KVA DG Set complete all as specified and as directed by Engineer-in-Charge. |
| 35 | All as per srl item No. 7.00 here-in-before but for capacity 125 KVA DG Set. |
| 36 | All as per srl item No. 7.00 here-in-before but for capacity 62.5 KVA DG Set. |
| 37 | All as per srl item No. 7.00 here-in-before but for capacity 40 KVA DG Set. |
| 38 | Supply and replacement of lub oil pump for capacity of 500 KVA DG Set complete all as specified and as directed by Engineer-in-Charge. |
| 39 | All as per srl item No. 8.00 here-in-before but for capacity 62.5 KVA DG Set. |
| 40 | All as per srl item No. 8.00 here-in-before but for capacity 40 KVA DG Set. |
| 41 | Supply and replacement of auotmatic voltage regulator(AVR) 24 volt suitable for 500 KVA DG Set complete all as specified and as directed by Engineer-in-Charge. |
| 42 | All as per srl item No. 9.00 here-in-before but for capacity 180 KVA DG Set. |
| 43 | All as per srl item No. 9.00 here-in-before but for capacity 125 KVA DG Set. |
| 44 | All as per srl item No. 9.00 here-in-before but for capacity 62.5 KVA DG Set. |
| 45 | All as per srl item No. 9.00 here-in-before but for capacity 40 KVA DG Set. |
| 46 | Strip opening of alternator of Capacity 500 KVA DG Set, removing rotor from the stator and rewinding to CT coils complete with super enameled copper winding wire of appropriate size including insulating material and replacing the following parts of the alternator.Note:- Re-assembling all the component of the alternator and mounting the same on the existing foundation including welding of alternator foundation plate by electric arc welding ,aligning the alternator with engine and testing on full load as specified in particular specification complete all as specified and as directed by Engineer-in-Charge. |
| 47 | All as per srl item No. 10.00 here-in-before but for capacity 62.5 KVA DG Set. |
| 48 | All as per srl item No. 10.00 here-in-before but for capacity 40 KVA DG Set. |
| 49 | Material and labour cleaning of radiator of 500 KVA DG sets by using K oil and radiator cleaning solution (Ready to Wash) by pressure of pump and brush and necessary welding/ brezzing and Re-assembling after painting of the same complete all as specified and as directed by Engineer-in-Charge. |
| 50 | All as per srl item No. 11.00 here-in-before but for capacity 125 KVA DG Set. |
| 51 | All as per srl item No. 11.00 here-in-before but for capacity 62.5 KVA DG Set. |
| 52 | All as per srl item No. 11.00 here-in-before but for capacity 40 KVA DG Set. |
| 53 | Material and labour for Calibration of FIP including supply & fixing in replacement plunger, DV, governor wet O-Ring, Pin roll, barrel, Pin ball bearing spring, washer and testing suitable for for 500 KVA DG Set complete all as specified and directed by Engr-in-Charge. |
| 54 | All as per srl item No. 12.00 here-in-before but for capacity 180 KVA DG Set. |
| 55 | All as per srl item No. 12.00 here-in-before but for capacity 125 KVA DG Set. |
| 56 | All as per srl item No. 12.00 here-in-before but for capacity 62.5 KVA DG Set. |
| 57 | All as per srl item No. 12.00 here-in-before but for capacity 40 KVA DG Set. |
| 58 | Supply and replacement of Piston ring set suitable for capacity of 500 KVA DG Set complete all as specified and as directed by Engineer-in-Charge. |
| 59 | All as per srl item No. 13.00 here-in-before but for capacity 125 KVA DG Set. |
| 60 | All as per srl item No. 13.00 here-in-before but for capacity 62.5 KVA DG Set. |
| 61 | All as per srl item No. 13.00 here-in-before but for capacity 40 KVA DG Set. |
| 62 | Supply and replacement of Cylinder Liner set suitable for capacity of 500 KVA DG Set complete all as specified and as directed by Engineer-in-Charge. |
| 63 | All as per srl item No. 14.00 here-in-before but for capacity 125 KVA DG Set. |
| 64 | All as per srl item No. 14.00 here-in-before but for capacity 62.5 KVA DG Set. |
| 65 | All as per srl item No. 14.00 here-in-before but for capacity 40 KVA DG Set. |
| 66 | Supply and replacement of Valve guide suitable for capacity of 500 KVA DG Set complete all as specified and as directed by Engineer-in-Charge. |
| 67 | All as per srl item No. 15.00 here-in-before but for capacity 125 KVA DG Set. |
| 68 | All as per srl item No. 15.00 here-in-before but for capacity 62.5 KVA DG Set. |
| 69 | All as per srl item No. 15.00 here-in-before but for capacity 40 KVA DG Set. |
| 70 | Supply and replacement of came bush suitable for capacity of 500 KVA DG Set complete all as specified and as directed by Engineer-in-Charge. |
| 71 | All as per srl item No. 16.00 here-in-before but for capacity 125 KVA DG Set. |
| 72 | All as per srl item No. 16.00 here-in-before but for capacity 62.5 KVA DG Set. |
| 73 | All as per srl item No. 16.00 here-in-before but for capacity 40 KVA DG Set. |
| 74 | Supply and replacement of Fuel Spray Nozzle suitable for capacity of 500 KVA DG Set complete all as specified and as directed by Engineer-in-Charge. |
| 75 | All as per srl item No. 17.00 here-in-before but for capacity 62.5 KVA DG Set. |
| 76 | All as per srl item No. 17.00 here-in-before but for capacity 40 KVA DG Set. |
| 77 | Supply and replacement of Head Gasket suitable for capacity of 500 KVA DG Set complete all as specified and as directed by Engineer-in-Charge. |
| 78 | All as per srl item No. 18.00 here-in-before but for capacity 125 KVA DG Set. |
| 79 | All as per srl item No. 18.00 here-in-before but for capacity 62.5 KVA DG Set. |
| 80 | All as per srl item No. 18.00 here-in-before but for capacity 40 KVA DG Set. |
| 81 | Supply and replacement of Dynamo/Alternator Assy for capacity 500 KVA DG Set complete all as specified and as directed by Engineer-in-Charge. |
| 82 | All as per srl item No. 19.00 here-in-before but for capacity 62.5 KVA DG Set. |
| 83 | All as per srl item No. 19.00 here-in-before but for capacity 40 KVA DG Set. |
| 84 | Supply and replacement of Fan Hub assembely for capacity of 500 KVA DG Set complete all as specified and as directed by Engineer-in-Charge. |
| 85 | All as per srl item No. 20.00 here-in-before but for capacity 62.5 KVA DG Set. |
| 86 | All as per srl item No. 20.00 here-in-before but for capacity 40 KVA DG Set. |
| 87 | Supply and Replacement of battery terminal for DG Sets complete all as specified and as directed by Engineer-in-Charge. |
| 88 | Supply and replacement Battery 12 Volt 180 AH (Maint free heavy duty) with initial charging complete all as specified and as directed by Engineer-in-Charge. |
| 89 | Supply and replacement Battery 12 Volt 80 AH (Maint free heavy duty) with initial charging complete all as specified and as directed by Engineer-in-Charge. |
| 90 | Supply only Engine oil 20 W 40 of best quality complete all as specified and as directed by Engineer-in-Charge. |
| 91 | Supply only coolent of best quality complete all as specified and complete by Engineer-in-Charge. |
| 92 | Supply only distilled water of best quality in 05 litrs sealed gallon packing complete all as specified and as directed by Engineer-in-Charge. |
| 93 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for taking out pipe line etc for repairs / laying cables etc and getting out in soft / loose soil complete all as specified and as directed by the Engineer - in - Charge. |
| 94 | Excavation in trenches not exceeding 1.5 m wide and beyond the first 1.5 m in depth for taking out pipe line etc for repairs / laying cables etc and getting out in soft / loose soil complete all as specified and as directed by the Engineer - in - Charge. |
| 95 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer - in - Charge. |
| 96 | Removal of excavated material [soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed by the Engineer - in - Charge. |
| 97 | Dismantling/Taking down existing unserviceable any type of ACSR conductor of any make and removing from site or setting aside for reuse complete all as specified and as directed by Engr in charge. |
| 98 | Supply and fixed in repair for aluminium conductor steel re-inforced (ACSR) any size any type as required at site(singe or mutiple run as directed) for LT lines on existing LT steel tubular poles, stretching without kinks and bends, binding with (rates inclusive) binding wire complete all as specified and as directed by the Engineer - in - Charge. |
| 99 | M&L in repair for dismantling cross arms MS Channel or angle section etc complete all as specified and as directed by the Engineer - in - Charge. |
| 100 | Material and labour in repair for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including bolts, nuts & washers, welding, bending cold or hot, drilling holes for inserting bolts, in any shape or size, as directed and inclusive of painting with two coats of aluminium paint over one coat of red-oxide primer complete all as specified and as directed by the Engineer - in - Charge. |
| 101 | M&L in repair for dismantling HT/LT insulator any type any size complete all as specified and as directed by the Engineer - in - Charge. |
| 102 | M&L in repair for fixing of Polymer Pin type porcelain, vitreous, white, brown or green Insulator incl one mild steel spindle, two iron washerrs,and iron nut, 100 mm height, 65 mm dia ,suitable for 1100 Volt, complete all as specified and as directed by the Engineer - in - Charge. |
| 103 | Material and labour in repair for Polymer Disc type insulator, porcelain, vitreous145 mm high and 255mm dia ball and socket type, white, brown or green, suitable for 11000 Volt, complete all as specified and as directed by Engineer-in-Charge. |
| 104 | Material and labour in repair for shackle type insulator porcelain, vitreous white brown insulator incl galvanised mild steel straps, washers insulator, bolts, washers and nuts of size 100 mm height, 115mm dia, section of strap 31 x 3 mm, dia of bolts 12 mm working pressure 1100 Volts complete all as specified and as directed by Engineer-in-Charge |
| 105 | M&L in repair for unbinding of the ACSR conductor form insulator on pole Pruning, tree branches 2 mtr all arround conductor and , restringing ACSR conductor, tightening of LT /HT OH Line, binding to the insulators using required size of aluminium binding wire complete all as directed by Engr-in-charge of 2 to 6 conductors. |
| 106 | Supply and fixing in replacement LT overhead line polypropylene composite 3/4 line separators molded or bolted type phase to phase distance 600 mm, width 25mm, thickness 12 mm complete all as specified and directed by Engr-in-charge. |
| 107 | M&L in repair for dismantling of old steel pole / struts any type and size including demolition of concrete, foundation, necessary excavation and earth work and transportation etc. complete all as specified and as directed by the Engineer - in - Charge. |
| 108 | Supply and errect in replacement of Steel Tubular Swaged Pole complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP - 31, 9.0 Mtrs long all including two coats of aluminium paint over a coat of red oxide and two coats of bituminous paint inside and outside of bottom portion up to 1.8 Mtr length complete all as specified and as directed by the Engineer - in - Charge. |
| 109 | Supplying and laying in replacement of GI pipe, 80mm dia, Light grade for cable protection at pole/road crossing etc including necessary road cutting and making good with PCC 1:2:4, Type B-1, using 20mm graded stone aggregate, 100mm thick or fixing on wall / poles of any type, secured with clamps, complete all as specified and as directed by the Engineer - in - Charge. |
| 110 | M&L in repair for PCC 1:4:8 type D2 using 40mm graded aggregate for pole / struts foundation etccomplete all as specified and as directed by the Engineer - in - Charge. |
| 111 | M&L in repair for PCC 1:3:6 type C1 using 20mm graded aggregate for coping including necessary form work and fair finishing of exposed surface of concrete complete all as specified and as directed by the Engineer - in - Charge.NOTE : Volume of poles / strut/pipes embedded in concrete shall be deducted for the purpose of payment. |
| 112 | M&L in repair for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in coping & bed block etc. including weathering, slightly rounded or chamfered agnels and throating including necessary form work, finishing the exposed surfaces of the concrete even and smooth without using extra cement complete all as specified and directed.Note:- Volume of pole/strut/stays embedded in concrete shall be deducted for the prupose of payment). |
| 113 | M&L in repair for preparation of surface of steel tubuler HT/LT poles all including nubers of cross arms, channels, clamps, street light brackets and GI protection pipes etc which are fitted on pole, by scrapping, applying two coats of aluminium paint and marking pole Nos on each pole with red and black colour radium paint alternate strips, 15 cm in width of each strip upto 1 m from bottom of the pole complete all as specified and as directed by the Engineer - in - Charge. |
| 114 | M&L in repair for disconnecting the all connection in existing panel board complete and re-fixing the same after replacing the burnt lugs/thimbles complete including replacement of the unservicable MCCBs, Contactors, over load relay, bus bar, indicator lamps etc.,complete all as specified and as directed by the Engineer - in - Charge. Note:- Replacement of major items shall be measured and paid for separately under respective. |
| 115 | Supply and fixed in replacement of MCCB 250 Amps 25 KA, 4 Pole complete all as specified and directed by Engr-in-Charge. |
| 116 | Supply and fixed in replacement of MCCB 100 Amps 16 KA, 3 Pole complete all as specified and directed by Engr-in-Charge. |
| 117 | Supply and fixed in replacement of MCCB 63 Amps 16 KA, 3 Pole complete all as specified and directed by Engr-in-Charge. |
| 118 | S&F in replacement of changeover switch on load 4 pole 200 Amp complete all as specified and directed by Engr - in - charge. |
| 119 | Supply and fixed in repairs Voltmeter 0-500 volt square type complete with necessary fixing all as specified and as directed by Engineer-in-Charge |
| 120 | Supply and fix in repairs ammeter 0-100 amps square type complete with necessary fixing all as specified and as directed by Engineer-in-Charge |
| 121 | Supply and fixed in replacement change over on Load 100 Amps 4 pole, 415 V housed in sheet metal enclosure including, replacement of incoming and outgoing cable connections with aluminium conductor cable, lugs, nuts, bolts complete all as specified and as directed by the Engineer - in - Charge. |
| 122 | Supply and Fixing in replacement Aluminium Thimble of size 10/16/35/50/70/95 sqmm, complete all as specified and directed by Engineer - in - Charge. |
| 123 | Supply and Fixing in replacement Aluminium Thimble of size 120/150/185/240/300 sqmm, complete all as specified and directed by Engineer - in - Charge. |
| 124 | M&L in repair for Cable jointing kit for LT UG cable with 1100 volts straight through joints kit epoxy type of size 50 to 120 sqmm 3.5 core, complete all as specified and directed by Engineer - in - Charge. |
| 125 | M&L in repair for Cable jointing kit for LT UG cable with 1100 volts straight through joints kit epoxy type of size 120 to 185 sqmm 3.5 core, complete all as specified and directed by Engineer - in - Charge. |
| 126 | Material and labour in repair for repairs to LT panel boards complete with necessary welding works to doors, replacement of unserviceable hinges and all drop bolt complete and painting with one coat of synthetic enamel paint of approved color internally and externally all as specified and as directed by Engineer-in-Charge |
| 127 | Taking out old unserviceable underground cable of any size/ make/ type etc from excavated trenches/ on poles/ passing through pipes etc from different locations complete all as specified and directed by Engr-in -Charge. |
| 128 | Laying & connecting only any type any size of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, for LT cable complete all as specified and directed by Engr-in -Charge. (Note : Cable will be issued under Sch 'B' for laying.) |
| 129 | Supply, laying and testing in repair for XLPE insulated, screened, PVC bedded galvanised steel strip armoured electric power cable (Heavy duty) with aluminium conductor, 1100 Volts grade lay in trenches, ducts, along pole cross sectional area 50 Sqmm 3.5 Core complete all as specified and directed by Engr-in -Charge. |
| 130 | Supply, laying and testing in repair for XLPE insulated, screened, PVC bedded galvanised steel strip armoured electric power cable (Heavy duty) with aluminium conductor, 1100 Volts grade lay in trenches, ducts, along pole cross sectional area 70 Sqmm 3.5 Core complete all as specified and directed by Engr-in -Charge. |
| 131 | Supply, laying and testing in repair for XLPE insulated, screened, PVC bedded galvanised steel strip armoured electric power cable (Heavy duty) with aluminium conductor, 1100 Volts grade lay in trenches, ducts, along pole cross sectional area 95 Sqmm 3.5 Core complete all as specified and directed by Engr-in -Charge. |
| 132 | Supply, laying and testing in repair for XLPE insulated, screened, PVC bedded galvanised steel strip armoured electric power cable (Heavy duty) with aluminium conductor, 1100 Volts grade lay in trenches, ducts, along pole cross sectional area 120 Sqmm 3.5 Core complete all as specified and directed by Engr-in -Charge. |
| 133 | Taking up old unserviceable / serviceable un reinforced concrete PCC cable covers from excavated trenches complete all as specified and directed by Engr-in -Charge.(Note : serviceable reinforce concrete PCC cable cover kept in safe custody for reuse at site and unserviceable reinforce concrete PCC cable cover thrown in low lying areas.) |
| 134 | Laying only in repair for old un reinforced PCC cable cover of any size as retrieved from above serial No.41 complete all as specified and directed by Engr-in -Charge. |
| 135 | M&L in repair for Un reinforced pre cast concrete cable cover class LV type I, flat size 250 mm x 150 mm x 40 mm. complete all as specified and directed by Engr-in -Charge. |
| 136 | M&L in repair for sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I complete all as specified and directed by Engr-in -Charge.(Note:-Punned thickness shall be measured and paid) |
| 137 | S&F in repair for PVC weather proof, hinged door, junction box with 10A Aluminium bus bar, 240V, Neutral link and 1No MCB SP of 6 Amps, necessary fixing arrangement such as clamps, nut, bolts, etc including dismantling old unservieable junction box complete all as specified and directed by Engr-in -Charge. |
| 138 | M&L in repair for Air termination, single pointed, aluminium rod 12mm dia and 300mm long different locations / Bldg complete all as specified and directed by the engr in charge. |
| 139 | M&L in repair for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed by the engr in charge. |
| 140 | S&F in-repair of Aluminium strip of size 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground., complete all as specified and as directed. |
| 141 | S&F in-repair of Galvanised iron strip of size 32 x 6mm buried in ground., complete all as specified and as directed. |
| 142 | S&F in replacement of galvanised earth lead wire 4.0mm dia for roof conductors or earthing and down conductors above ground complete all as specified and directed by the engr in charge. |
| 143 | M&L in repair for dismantling and taking down LT U/S panels incl all outgoing and incoming connections and making good the disturbed area from site all as specified and directed by the engr in charge. |
| 144 | Supply installing commissioning & testing in repair for LT panel board with suitable rating of APFC panel factory made, out door, kiosk type, vermin proof, dust proof, water proof made out of 5 mm thick CRCA sheetand angle iron frame of size 50x50x6 mm inside depth not less than 50 cm and size suitable to accomodate the following accessories with insulated aluminium bus bar 250 Amps capacity 3 phase 4 wire system both side openable (front & back) with locking arrangement duly painted with coat of synthetic enamel paint over a coat of red oxide primer both internally and externally and connecting with cable with lugs including internal wiring with copper cable of suitable size using lugs compressing the following accessories all as directed. (Notes : The rate quoted shall include for earth work & excavation for angle iron frame for foundation of panel board upto 0.50 m below GL in any type of soil & PCC (1:4:8), D2 filling in foundation the ground clearance of panel board shall be 0.40 m GL to the bottom of panel board )(a) MCCB 400 Amps, 4 pole, 415 Volts, 50 Hz ICU 35 KA thermally adjustable between 70-100% - 01 No- incoming(b) MCCB 160 Amps, 3 pole, 415 Volts, 50 Hz ICU 25 KA thermally adjustable between 70-100% - 03 Nos.(c) MCCB 63 Amps, 3 pole, 415 Volts, 50 Hz ICU 16 KA thermally adjustable between 70-100% - 02 Nos (d) Digital type Ammeter with CTs(e) Digital type VoltmeterAC with selector switch - 01 No(f) Indicator lamps RYB - 01 set |
| 145 | M&L in replacement for Busbar chambers with 4 aluminium busbar strip of rating 200 Amp 6 way fixed on angle iron of size 40mm x40mm x5mm complete all as specified and directed by Engineer in Charge. |
| 146 | M&L in repair for earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6.3) mm thick buried directly into ground vertically to depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, surrounded on all sides by alternate layers of 150 mm thick charcoal and common salt, connected to galvanized earh lead wire of size 4.0 mm by means of lugs, bolts, nuts, washer, check nuts of galvanised iron or steel all as shown in Electrical plate No. 3, wire protected by dia 15 mm bore light grade GI Pipe laid in floor and fixed to wall with proper size of clamps and watering pipe of bore 20 mm dia GI light grade including wire mesh funnel, PCC, earth chamber pit with PCC 1:2:4 type B-1 using 20 mm grade stone aggreate including form work cement mortar including CI Pit cover with frame necessary excavation and earth work in any type of soil including testing complete all as specified and as directed by Engineer-in-Charge. |
| 147 | M&L in repair for earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip 32 x 6 mm ( incl upto 7.5 mtr) by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion with charcoal dust and common salt all as shown in electrical plate No 5 of MES SSR Part-I , all excavation and earth work & connectiing the earthing to an earthing test point as specified and testing on complete all as specified & directed by Engr-in-Charge. |
| 148 | Note:-The accepted amount will be arrived after deducting the Sch of credit i.e. Rs 87,454.00 and any other reduction if any from quoted amount. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 08, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysOct 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender