Defence Statutory Bodies & Commissions/Committees Closing in 19 days TDR #57942166

Tender For Repair/Maint Of Lt Panels Including Apfc Panels, Earthing, Dg Sets And Connected Items Installed At Nimu, Sangam Hill And Nanak Hill At Nimu Mil Stn Under Age (I) Nimu

Issued by Statutory Bodies & Commissions/Committees · Leh, Ladakh
Tender Value
35 Lakhs
Estimated cost
Bid Submission
29 Oct 2026
19 days left
EMD
70000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Leh → Ladakh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maint Of Lt Panels Including Apfc Panels, Earthing, Dg Sets And Connected Items Installed At Nimu, Sangam Hill And Nanak Hill At Nimu Mil Stn Under Age (I) Nimu

BOQ

Name of Work:- REPAIR/MAINT OF LT PANELS INCLUDING APFC PANELS, EARTHING, DG SETS AND CONNECTED ITEMS INSTALLED AT NIMU, SANGAM HILL AND NANAK HILL AT NIMU MIL STN UNDER AGE (I) NIMU
Sl. No. Item Description
1Checking, Inspection, maintanance and servicing complete including replacement of unserviceable spare parts of the DG set (comparising of Engine/ Alternator/ Control panel) of capacity 500 KVA DG Sets at 25 Grndr & Power house for smoth functioning complete all as per manufacturers instructions and all as directed by Engr-in-Charge.(a) Checking of lubricating oil condition (b) Checking engine for oil, water leakage and correcting the same(c) Checking of all the nut bolts of engine and alternator (d) Checking of all belts and adjust the tension properly (e) Cleaning of air filters(f) Checking and readjusting the valve clearance(g) Change of Oil/Fuel filters and engine oil if necessary(h) Checking of starter motor battery and charger(i) Checking of cooling system and fuel system(j) checking of all power cables and AVR connections and mounting bolt tightness of alternator(k) checking the function of AVR general checks (l) Checking of control panel meters and gadgets functioning(m) Checking of all control and safety wirings(n) Checking of flexible coupling of engine and alternator (o) Cleaning of crank case ventilation pipe(p) Checking of injectors and fuel pumpNOTES: (1) Cost of Spares required will be paid and measured separately under item No 1.01 to 1.05 of BOQ(2) Servicing/routine check up carried out through authorised service centre of manufacturer.(3) Make of spare recommendation by auth service centre of manufacturer.Checking of alternator and carbon brushes.
2Supply only 'V' belt for water pump
3Supply only fuel pipe with banjo bolt at both side
4Supply only oil filter element
5Supply only air cleaner element (inner and outer)
6Supply only fuel filter element (primary and secondary)
7All as per Srl item No. 1.00 above but DG Set of capacity 180 KVA complete all as specified and as directed by Engineer-in-Charge. NOTES: (1) Cost of Spares required will be paid and measured separately under item No 2.01 to 2.05 of BOQ(2) Servicing/routine check up carried out through authorised service centre of manufacturer.(3) Make of spare recommendation by auth service centre of manufacturer.Checking of alternator and carbon brushes.
8Supply only 'V' belt for water pump
9Supply only fuel pipe with banjo bolt at both side
10Supply only oil filter element
11Supply only air cleaner element (inner and outer)
12Supply only fuel filter element (primary and secondary)
13All as per Srl item No. 1.00 above but DG Set of capacity 125 KVA complete all as specified and as directed by Engineer-in-Charge. NOTES: (1) Cost of Spares required will be paid and measured separately under item No 3.01 to 3.05 of BOQ(2) Servicing/routine check up carried out through authorised service centre of manufacturer.(3) Make of spare recommendation by auth service centre of manufacturer.Checking of alternator and carbon brushes.
14Supply only 'V' belt for water pump
15Supply only fuel pipe with banjo bolt at both side
16Supply only oil filter element
17Supply only air cleaner element (inner and outer)
18Supply only fuel filter element (primary and secondary)
19All as per Srl item No. 1.00 above but DG Set of capacity 62.5 KVA complete all as specified and as directed by Engineer-in-Charge. NOTES: (1) Cost of Spares required will be paid and measured separately under item No 4.01 to 4.05 of BOQ(2) Servicing/routine check up carried out through authorised service centre of manufacturer.(3) Make of spare recommendation by auth service centre of manufacturer.Checking of alternator and carbon brushes.
20Supply only 'V' belt for water pump
21Supply only fuel pipe with banjo bolt at both side
22Supply only oil filter element
23Supply only air cleaner element (inner and outer)
24Supply only fuel filter element (primary and secondary)
25All as per Srl item No. 1.00 above but DG Set of capacity 40 KVA complete all as specified and as directed by Engineer-in-Charge. NOTES: (1) Cost of Spares required will be paid and measured separately under item No 5.01 to 5.05 of BOQ(2) Servicing/routine check up carried out through authorised service centre of manufacturer.(3) Make of spare recommendation by auth service centre of manufacturer.Checking of alternator and carbon brushes.
26Supply only 'V' belt for water pump
27Supply only fuel pipe with banjo bolt at both side
28Supply only oil filter element
29Supply only air cleaner element (inner and outer)
30Supply only fuel filter element (primary and secondary)
31Supply and replacement of Turbo Charger assy for 500 KVA DG Set complete all as specified and as directed by Engineer-in-Charge.
32All as per srl item No. 6.00 here-in-before but for capacity 62.5 KVA DG Set.
33All as per srl item No. 6.00 here-in-before but for capacity 40 KVA DG Set.
34Supply and replacement of self starter of capacity 500 KVA DG Set complete all as specified and as directed by Engineer-in-Charge.
35All as per srl item No. 7.00 here-in-before but for capacity 125 KVA DG Set.
36All as per srl item No. 7.00 here-in-before but for capacity 62.5 KVA DG Set.
37All as per srl item No. 7.00 here-in-before but for capacity 40 KVA DG Set.
38Supply and replacement of lub oil pump for capacity of 500 KVA DG Set complete all as specified and as directed by Engineer-in-Charge.
39All as per srl item No. 8.00 here-in-before but for capacity 62.5 KVA DG Set.
40All as per srl item No. 8.00 here-in-before but for capacity 40 KVA DG Set.
41Supply and replacement of auotmatic voltage regulator(AVR) 24 volt suitable for 500 KVA DG Set complete all as specified and as directed by Engineer-in-Charge.
42All as per srl item No. 9.00 here-in-before but for capacity 180 KVA DG Set.
43All as per srl item No. 9.00 here-in-before but for capacity 125 KVA DG Set.
44All as per srl item No. 9.00 here-in-before but for capacity 62.5 KVA DG Set.
45All as per srl item No. 9.00 here-in-before but for capacity 40 KVA DG Set.
46Strip opening of alternator of Capacity 500 KVA DG Set, removing rotor from the stator and rewinding to CT coils complete with super enameled copper winding wire of appropriate size including insulating material and replacing the following parts of the alternator.Note:- Re-assembling all the component of the alternator and mounting the same on the existing foundation including welding of alternator foundation plate by electric arc welding ,aligning the alternator with engine and testing on full load as specified in particular specification complete all as specified and as directed by Engineer-in-Charge.
47All as per srl item No. 10.00 here-in-before but for capacity 62.5 KVA DG Set.
48All as per srl item No. 10.00 here-in-before but for capacity 40 KVA DG Set.
49Material and labour cleaning of radiator of 500 KVA DG sets by using K oil and radiator cleaning solution (Ready to Wash) by pressure of pump and brush and necessary welding/ brezzing and Re-assembling after painting of the same complete all as specified and as directed by Engineer-in-Charge.
50All as per srl item No. 11.00 here-in-before but for capacity 125 KVA DG Set.
51All as per srl item No. 11.00 here-in-before but for capacity 62.5 KVA DG Set.
52All as per srl item No. 11.00 here-in-before but for capacity 40 KVA DG Set.
53Material and labour for Calibration of FIP including supply & fixing in replacement plunger, DV, governor wet O-Ring, Pin roll, barrel, Pin ball bearing spring, washer and testing suitable for for 500 KVA DG Set complete all as specified and directed by Engr-in-Charge.
54All as per srl item No. 12.00 here-in-before but for capacity 180 KVA DG Set.
55All as per srl item No. 12.00 here-in-before but for capacity 125 KVA DG Set.
56All as per srl item No. 12.00 here-in-before but for capacity 62.5 KVA DG Set.
57All as per srl item No. 12.00 here-in-before but for capacity 40 KVA DG Set.
58Supply and replacement of Piston ring set suitable for capacity of 500 KVA DG Set complete all as specified and as directed by Engineer-in-Charge.
59All as per srl item No. 13.00 here-in-before but for capacity 125 KVA DG Set.
60All as per srl item No. 13.00 here-in-before but for capacity 62.5 KVA DG Set.
61All as per srl item No. 13.00 here-in-before but for capacity 40 KVA DG Set.
62Supply and replacement of Cylinder Liner set suitable for capacity of 500 KVA DG Set complete all as specified and as directed by Engineer-in-Charge.
63All as per srl item No. 14.00 here-in-before but for capacity 125 KVA DG Set.
64All as per srl item No. 14.00 here-in-before but for capacity 62.5 KVA DG Set.
65All as per srl item No. 14.00 here-in-before but for capacity 40 KVA DG Set.
66Supply and replacement of Valve guide suitable for capacity of 500 KVA DG Set complete all as specified and as directed by Engineer-in-Charge.
67All as per srl item No. 15.00 here-in-before but for capacity 125 KVA DG Set.
68All as per srl item No. 15.00 here-in-before but for capacity 62.5 KVA DG Set.
69All as per srl item No. 15.00 here-in-before but for capacity 40 KVA DG Set.
70Supply and replacement of came bush suitable for capacity of 500 KVA DG Set complete all as specified and as directed by Engineer-in-Charge.
71All as per srl item No. 16.00 here-in-before but for capacity 125 KVA DG Set.
72All as per srl item No. 16.00 here-in-before but for capacity 62.5 KVA DG Set.
73All as per srl item No. 16.00 here-in-before but for capacity 40 KVA DG Set.
74Supply and replacement of Fuel Spray Nozzle suitable for capacity of 500 KVA DG Set complete all as specified and as directed by Engineer-in-Charge.
75All as per srl item No. 17.00 here-in-before but for capacity 62.5 KVA DG Set.
76All as per srl item No. 17.00 here-in-before but for capacity 40 KVA DG Set.
77Supply and replacement of Head Gasket suitable for capacity of 500 KVA DG Set complete all as specified and as directed by Engineer-in-Charge.
78All as per srl item No. 18.00 here-in-before but for capacity 125 KVA DG Set.
79All as per srl item No. 18.00 here-in-before but for capacity 62.5 KVA DG Set.
80All as per srl item No. 18.00 here-in-before but for capacity 40 KVA DG Set.
81Supply and replacement of Dynamo/Alternator Assy for capacity 500 KVA DG Set complete all as specified and as directed by Engineer-in-Charge.
82All as per srl item No. 19.00 here-in-before but for capacity 62.5 KVA DG Set.
83All as per srl item No. 19.00 here-in-before but for capacity 40 KVA DG Set.
84Supply and replacement of Fan Hub assembely for capacity of 500 KVA DG Set complete all as specified and as directed by Engineer-in-Charge.
85All as per srl item No. 20.00 here-in-before but for capacity 62.5 KVA DG Set.
86All as per srl item No. 20.00 here-in-before but for capacity 40 KVA DG Set.
87Supply and Replacement of battery terminal for DG Sets complete all as specified and as directed by Engineer-in-Charge.
88Supply and replacement Battery 12 Volt 180 AH (Maint free heavy duty) with initial charging complete all as specified and as directed by Engineer-in-Charge.
89Supply and replacement Battery 12 Volt 80 AH (Maint free heavy duty) with initial charging complete all as specified and as directed by Engineer-in-Charge.
90Supply only Engine oil 20 W 40 of best quality complete all as specified and as directed by Engineer-in-Charge.
91Supply only coolent of best quality complete all as specified and complete by Engineer-in-Charge.
92Supply only distilled water of best quality in 05 litrs sealed gallon packing complete all as specified and as directed by Engineer-in-Charge.
93Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for taking out pipe line etc for repairs / laying cables etc and getting out in soft / loose soil complete all as specified and as directed by the Engineer - in - Charge.
94Excavation in trenches not exceeding 1.5 m wide and beyond the first 1.5 m in depth for taking out pipe line etc for repairs / laying cables etc and getting out in soft / loose soil complete all as specified and as directed by the Engineer - in - Charge.
95Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer - in - Charge.
96Removal of excavated material [soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed by the Engineer - in - Charge.
97Dismantling/Taking down existing unserviceable any type of ACSR conductor of any make and removing from site or setting aside for reuse complete all as specified and as directed by Engr in charge.
98Supply and fixed in repair for aluminium conductor steel re-inforced (ACSR) any size any type as required at site(singe or mutiple run as directed) for LT lines on existing LT steel tubular poles, stretching without kinks and bends, binding with (rates inclusive) binding wire complete all as specified and as directed by the Engineer - in - Charge.
99M&L in repair for dismantling cross arms MS Channel or angle section etc complete all as specified and as directed by the Engineer - in - Charge.
100Material and labour in repair for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including bolts, nuts & washers, welding, bending cold or hot, drilling holes for inserting bolts, in any shape or size, as directed and inclusive of painting with two coats of aluminium paint over one coat of red-oxide primer complete all as specified and as directed by the Engineer - in - Charge.
101M&L in repair for dismantling HT/LT insulator any type any size complete all as specified and as directed by the Engineer - in - Charge.
102M&L in repair for fixing of Polymer Pin type porcelain, vitreous, white, brown or green Insulator incl one mild steel spindle, two iron washerrs,and iron nut, 100 mm height, 65 mm dia ,suitable for 1100 Volt, complete all as specified and as directed by the Engineer - in - Charge.
103Material and labour in repair for Polymer Disc type insulator, porcelain, vitreous145 mm high and 255mm dia ball and socket type, white, brown or green, suitable for 11000 Volt, complete all as specified and as directed by Engineer-in-Charge.
104Material and labour in repair for shackle type insulator porcelain, vitreous white brown insulator incl galvanised mild steel straps, washers insulator, bolts, washers and nuts of size 100 mm height, 115mm dia, section of strap 31 x 3 mm, dia of bolts 12 mm working pressure 1100 Volts complete all as specified and as directed by Engineer-in-Charge
105M&L in repair for unbinding of the ACSR conductor form insulator on pole Pruning, tree branches 2 mtr all arround conductor and , restringing ACSR conductor, tightening of LT /HT OH Line, binding to the insulators using required size of aluminium binding wire complete all as directed by Engr-in-charge of 2 to 6 conductors.
106Supply and fixing in replacement LT overhead line polypropylene composite 3/4 line separators molded or bolted type phase to phase distance 600 mm, width 25mm, thickness 12 mm complete all as specified and directed by Engr-in-charge.
107M&L in repair for dismantling of old steel pole / struts any type and size including demolition of concrete, foundation, necessary excavation and earth work and transportation etc. complete all as specified and as directed by the Engineer - in - Charge.
108Supply and errect in replacement of Steel Tubular Swaged Pole complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP - 31, 9.0 Mtrs long all including two coats of aluminium paint over a coat of red oxide and two coats of bituminous paint inside and outside of bottom portion up to 1.8 Mtr length complete all as specified and as directed by the Engineer - in - Charge.
109Supplying and laying in replacement of GI pipe, 80mm dia, Light grade for cable protection at pole/road crossing etc including necessary road cutting and making good with PCC 1:2:4, Type B-1, using 20mm graded stone aggregate, 100mm thick or fixing on wall / poles of any type, secured with clamps, complete all as specified and as directed by the Engineer - in - Charge.
110M&L in repair for PCC 1:4:8 type D2 using 40mm graded aggregate for pole / struts foundation etccomplete all as specified and as directed by the Engineer - in - Charge.
111M&L in repair for PCC 1:3:6 type C1 using 20mm graded aggregate for coping including necessary form work and fair finishing of exposed surface of concrete complete all as specified and as directed by the Engineer - in - Charge.NOTE : Volume of poles / strut/pipes embedded in concrete shall be deducted for the purpose of payment.
112M&L in repair for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in coping & bed block etc. including weathering, slightly rounded or chamfered agnels and throating including necessary form work, finishing the exposed surfaces of the concrete even and smooth without using extra cement complete all as specified and directed.Note:- Volume of pole/strut/stays embedded in concrete shall be deducted for the prupose of payment).
113M&L in repair for preparation of surface of steel tubuler HT/LT poles all including nubers of cross arms, channels, clamps, street light brackets and GI protection pipes etc which are fitted on pole, by scrapping, applying two coats of aluminium paint and marking pole Nos on each pole with red and black colour radium paint alternate strips, 15 cm in width of each strip upto 1 m from bottom of the pole complete all as specified and as directed by the Engineer - in - Charge.
114M&L in repair for disconnecting the all connection in existing panel board complete and re-fixing the same after replacing the burnt lugs/thimbles complete including replacement of the unservicable MCCBs, Contactors, over load relay, bus bar, indicator lamps etc.,complete all as specified and as directed by the Engineer - in - Charge. Note:- Replacement of major items shall be measured and paid for separately under respective.
115Supply and fixed in replacement of MCCB 250 Amps 25 KA, 4 Pole complete all as specified and directed by Engr-in-Charge.
116Supply and fixed in replacement of MCCB 100 Amps 16 KA, 3 Pole complete all as specified and directed by Engr-in-Charge.
117Supply and fixed in replacement of MCCB 63 Amps 16 KA, 3 Pole complete all as specified and directed by Engr-in-Charge.
118S&F in replacement of changeover switch on load 4 pole 200 Amp complete all as specified and directed by Engr - in - charge.
119Supply and fixed in repairs Voltmeter 0-500 volt square type complete with necessary fixing all as specified and as directed by Engineer-in-Charge
120Supply and fix in repairs ammeter 0-100 amps square type complete with necessary fixing all as specified and as directed by Engineer-in-Charge
121Supply and fixed in replacement change over on Load 100 Amps 4 pole, 415 V housed in sheet metal enclosure including, replacement of incoming and outgoing cable connections with aluminium conductor cable, lugs, nuts, bolts complete all as specified and as directed by the Engineer - in - Charge.
122Supply and Fixing in replacement Aluminium Thimble of size 10/16/35/50/70/95 sqmm, complete all as specified and directed by Engineer - in - Charge.
123Supply and Fixing in replacement Aluminium Thimble of size 120/150/185/240/300 sqmm, complete all as specified and directed by Engineer - in - Charge.
124M&L in repair for Cable jointing kit for LT UG cable with 1100 volts straight through joints kit epoxy type of size 50 to 120 sqmm 3.5 core, complete all as specified and directed by Engineer - in - Charge.
125M&L in repair for Cable jointing kit for LT UG cable with 1100 volts straight through joints kit epoxy type of size 120 to 185 sqmm 3.5 core, complete all as specified and directed by Engineer - in - Charge.
126Material and labour in repair for repairs to LT panel boards complete with necessary welding works to doors, replacement of unserviceable hinges and all drop bolt complete and painting with one coat of synthetic enamel paint of approved color internally and externally all as specified and as directed by Engineer-in-Charge
127Taking out old unserviceable underground cable of any size/ make/ type etc from excavated trenches/ on poles/ passing through pipes etc from different locations complete all as specified and directed by Engr-in -Charge.
128Laying & connecting only any type any size of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, for LT cable complete all as specified and directed by Engr-in -Charge. (Note : Cable will be issued under Sch 'B' for laying.)
129Supply, laying and testing in repair for XLPE insulated, screened, PVC bedded galvanised steel strip armoured electric power cable (Heavy duty) with aluminium conductor, 1100 Volts grade lay in trenches, ducts, along pole cross sectional area 50 Sqmm 3.5 Core complete all as specified and directed by Engr-in -Charge.
130Supply, laying and testing in repair for XLPE insulated, screened, PVC bedded galvanised steel strip armoured electric power cable (Heavy duty) with aluminium conductor, 1100 Volts grade lay in trenches, ducts, along pole cross sectional area 70 Sqmm 3.5 Core complete all as specified and directed by Engr-in -Charge.
131Supply, laying and testing in repair for XLPE insulated, screened, PVC bedded galvanised steel strip armoured electric power cable (Heavy duty) with aluminium conductor, 1100 Volts grade lay in trenches, ducts, along pole cross sectional area 95 Sqmm 3.5 Core complete all as specified and directed by Engr-in -Charge.
132Supply, laying and testing in repair for XLPE insulated, screened, PVC bedded galvanised steel strip armoured electric power cable (Heavy duty) with aluminium conductor, 1100 Volts grade lay in trenches, ducts, along pole cross sectional area 120 Sqmm 3.5 Core complete all as specified and directed by Engr-in -Charge.
133Taking up old unserviceable / serviceable un reinforced concrete PCC cable covers from excavated trenches complete all as specified and directed by Engr-in -Charge.(Note : serviceable reinforce concrete PCC cable cover kept in safe custody for reuse at site and unserviceable reinforce concrete PCC cable cover thrown in low lying areas.)
134Laying only in repair for old un reinforced PCC cable cover of any size as retrieved from above serial No.41 complete all as specified and directed by Engr-in -Charge.
135M&L in repair for Un reinforced pre cast concrete cable cover class LV type I, flat size 250 mm x 150 mm x 40 mm. complete all as specified and directed by Engr-in -Charge.
136M&L in repair for sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I complete all as specified and directed by Engr-in -Charge.(Note:-Punned thickness shall be measured and paid)
137S&F in repair for PVC weather proof, hinged door, junction box with 10A Aluminium bus bar, 240V, Neutral link and 1No MCB SP of 6 Amps, necessary fixing arrangement such as clamps, nut, bolts, etc including dismantling old unservieable junction box complete all as specified and directed by Engr-in -Charge.
138M&L in repair for Air termination, single pointed, aluminium rod 12mm dia and 300mm long different locations / Bldg complete all as specified and directed by the engr in charge.
139M&L in repair for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed by the engr in charge.
140S&F in-repair of Aluminium strip of size 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground., complete all as specified and as directed.
141S&F in-repair of Galvanised iron strip of size 32 x 6mm buried in ground., complete all as specified and as directed.
142S&F in replacement of galvanised earth lead wire 4.0mm dia for roof conductors or earthing and down conductors above ground complete all as specified and directed by the engr in charge.
143M&L in repair for dismantling and taking down LT U/S panels incl all outgoing and incoming connections and making good the disturbed area from site all as specified and directed by the engr in charge.
144Supply installing commissioning & testing in repair for LT panel board with suitable rating of APFC panel factory made, out door, kiosk type, vermin proof, dust proof, water proof made out of 5 mm thick CRCA sheetand angle iron frame of size 50x50x6 mm inside depth not less than 50 cm and size suitable to accomodate the following accessories with insulated aluminium bus bar 250 Amps capacity 3 phase 4 wire system both side openable (front & back) with locking arrangement duly painted with coat of synthetic enamel paint over a coat of red oxide primer both internally and externally and connecting with cable with lugs including internal wiring with copper cable of suitable size using lugs compressing the following accessories all as directed. (Notes : The rate quoted shall include for earth work & excavation for angle iron frame for foundation of panel board upto 0.50 m below GL in any type of soil & PCC (1:4:8), D2 filling in foundation the ground clearance of panel board shall be 0.40 m GL to the bottom of panel board )(a) MCCB 400 Amps, 4 pole, 415 Volts, 50 Hz ICU 35 KA thermally adjustable between 70-100% - 01 No- incoming(b) MCCB 160 Amps, 3 pole, 415 Volts, 50 Hz ICU 25 KA thermally adjustable between 70-100% - 03 Nos.(c) MCCB 63 Amps, 3 pole, 415 Volts, 50 Hz ICU 16 KA thermally adjustable between 70-100% - 02 Nos (d) Digital type Ammeter with CTs(e) Digital type VoltmeterAC with selector switch - 01 No(f) Indicator lamps RYB - 01 set
145M&L in replacement for Busbar chambers with 4 aluminium busbar strip of rating 200 Amp 6 way fixed on angle iron of size 40mm x40mm x5mm complete all as specified and directed by Engineer in Charge.
146M&L in repair for earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6.3) mm thick buried directly into ground vertically to depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, surrounded on all sides by alternate layers of 150 mm thick charcoal and common salt, connected to galvanized earh lead wire of size 4.0 mm by means of lugs, bolts, nuts, washer, check nuts of galvanised iron or steel all as shown in Electrical plate No. 3, wire protected by dia 15 mm bore light grade GI Pipe laid in floor and fixed to wall with proper size of clamps and watering pipe of bore 20 mm dia GI light grade including wire mesh funnel, PCC, earth chamber pit with PCC 1:2:4 type B-1 using 20 mm grade stone aggreate including form work cement mortar including CI Pit cover with frame necessary excavation and earth work in any type of soil including testing complete all as specified and as directed by Engineer-in-Charge.
147M&L in repair for earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip 32 x 6 mm ( incl upto 7.5 mtr) by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion with charcoal dust and common salt all as shown in electrical plate No 5 of MES SSR Part-I , all excavation and earth work & connectiing the earthing to an earthing test point as specified and testing on complete all as specified & directed by Engr-in-Charge.
148Note:-The accepted amount will be arrived after deducting the Sch of credit i.e. Rs 87,454.00 and any other reduction if any from quoted amount. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57942166
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 35 Lakhs
LAST DATE 29-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint Of Lt Panels Including Apfc Panels, Earthing, Dg Sets And Connected Items Installed At Nimu, Sangam Hill And Nanak Hill At Nimu Mil Stn Under Age (I) Nimu
Basic Detail
Tender No 80051/41/2026-27
Bidding Type Tender
Location
City Leh
State Ladakh
Key Dates
Publish Date 08 Oct 2026
Submission Date 29 Oct 2026
Open Date 30 Oct 2026
Finance
Tender Value 35 Lakhs
Tender Fee 500
EMD 70000
Exemption Available
Document List
587b3517-d0e5-4991-bed9-2ce5fcc7be27.html
BOQ_889057.xls
TENDER41.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 08, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Oct 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
html

587b3517-d0e5-4991-bed9-2ce5fcc7be27.html

xls

BOQ_889057.xls

pdf

TENDER41.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail