Tender For Repair/Replacement & Maintenance Of Old Rusted External Water Supply Pipelines Of Various Sizes And Type, Valve Chamber, Distribution Network Various Size And Types Of Valve, Cleaning Of Service Tank And Over Head Tank Etc And Assosiated A
Tender Overview
Project Description
Tender for Repair/Replacement & Maintenance Of Old Rusted External Water Supply Pipelines Of Various Sizes And Type, Valve Chamber, Distribution Network Various Size And Types Of Valve, Cleaning Of Service Tank And Over Head Tank Etc And Assosiated Allied Works At Md Accn In Aundh Mil Station Under Ge (Mh & Rh) Khadki
BOQ
| Sl. No. | Item Description |
| 1 | Excavating in trenches, not exc. 1.5mtr wide and not exc. 1.5 mtr in depth for laying of pipe line in complete all as specified and directed for the following. |
| 2 | soft / loose soil |
| 3 | Hard/ dense soil |
| 4 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and directed. |
| 5 | Removing excavated meterial to a distance n.exc 50 mtr and depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and directed by Engineer-in-Charge |
| 6 | Taking up or taking down steel tubing and connections including cleaning for refixing or removal to store for the following sizes complete all as specified and directed :- |
| 7 | 15 mm dia |
| 8 | 20 mm dia |
| 9 | 25 mm dia |
| 10 | 40 mm dia |
| 11 | 50 mm dia |
| 12 | 80 mm dia |
| 13 | Relaying only GI tubes any grade in trenches materials obtained from Item No.4 here-in-before after cleaning or rerunning the old screw threads with replacement of unserviceable fittings and fixtures for following size complete all as specified and directed. |
| 14 | 15 mm dia |
| 15 | 20 mm dia |
| 16 | 25 mm dia |
| 17 | 40 mm dia |
| 18 | 50 mm dia |
| 19 | 80 mm dia |
| 20 | Supply and laying for galvanised iron tubing medium grade ISI Mark with and including all fittings such as bends, elbows, tees, short pieces, union etc in trenches complete all as specified and directed of following sizes :-. |
| 21 | 15 mm dia |
| 22 | 20 mm dia |
| 23 | 25 mm dia |
| 24 | 40 mm dia |
| 25 | 50 mm dia |
| 26 | 80 mm dia |
| 27 | Supply and fix gun metal gate valve ISI Mark with following mm dia with iron wheel head screwed both ends ISI marked fixed to GI pipe including removal old unserviceable one complete all as specified and directed. |
| 28 | 15 mm dia |
| 29 | 20 mm dia |
| 30 | 25 mm dia |
| 31 | 40 mm dia |
| 32 | 50 mm dia |
| 33 | 80 mm dia |
| 34 | Supply and fix in repairs Cast iron sluice valve with spindle and cast iron head wheel complying with IS:14846-2000, class PN 1.6 IS with inner working parts brass both ends flanged with 2 Nos rubber insertion gasket joints, nuts, bolts & washers of required size & Nos complete removing of unserviceable sluice vaulve from existing place the following bore complete all as specified and directed :- |
| 35 | 400 mm dia |
| 36 | 300 mm dia |
| 37 | 250 mm dia |
| 38 | 200 mm dia |
| 39 | 150 mm dia |
| 40 | 100 mm dia |
| 41 | 80 mm dia |
| 42 | Supply and fixing in repair cast iron air release valve , ISI marked both end flanged with nut bolt washers and rubber gasket confirming IS 4038, installation, testing of following sizes complete all as specified and directed. |
| 43 | 150 mm |
| 44 | 100mm |
| 45 | Supply and fixing in repairs cast iron body heavy duty non return valve ISI marked ( NRV) both ends flanged with 2 Nos rubber insertion gasket joints, nuts, bolts & washers of required size & Nos complete of the following bore complete all as specified and directed :- |
| 46 | 200 mm dia |
| 47 | 150 mm dia |
| 48 | 100 mm dia |
| 49 | 80 mm dia |
| 50 | Supply and fixing in repairs cast iron foot ball valve, normax type, ISI marked both end flanged with nut bolt washers and rubber gasket confirming to IS 4038, installation, testing of following sizes rates are include removal of existing foot valve complete all as specified and directed. |
| 51 | 200 mm dia |
| 52 | 150 mm dia. |
| 53 | 100 mm dia |
| 54 | 80 mm dia. |
| 55 | Taking up or taking down old unsv damaged / rusted CI / DI Pipe of the following sizes & dia with connections removal from the site, complete all as specified and directed :- |
| 56 | 400 mm dia. |
| 57 | 300 mm dia. |
| 58 | 200 mm dia. |
| 59 | 150 mm dia |
| 60 | 100 mm dia. |
| 61 | 80 mm dia. |
| 62 | Supply, Laying, jointing & testing of Ductile iron (DI), pressure pipes with spigot or socket ends or flange ends, centrifugally cast, class K-9, with cement mortar lining in inner side as per IS:8329/ 2000 (latest revision) and other relevant standards and metallic zinc coating followed by a finishing layer of epoxy paint in outer side, suitable for push on joint (rubber gasket joint) in any length with inside cement mortar lining laid in trenches complete all as specified and directed of following sizes:- Note : Excavation shall be measured and paid separately. |
| 63 | 400 mm dia |
| 64 | 300 mm dia |
| 65 | 200 mm dia |
| 66 | 150 mm dia |
| 67 | 100 mm dia |
| 68 | 80 mm dia |
| 69 | Material and labour in repair for cast iron/MS fitting for connecting pipes one end flanged and other end socket or spigot and bell mouth pieces one end flanged other end tapering as bell mouth, DI Bends tapers, Tees, pieces (Single or double branch) any Type and angle/ radius and straight connecting pieces for DI Pipe of following bore complete all as specified and directed.Note : 1. The rates include transportation, handling and placing in positgion the fittings in proposed loation and alignment of pipes as ordered.2. The rates also include for cuttings of pipe for insertion of fittings where necessitated in new works. |
| 70 | Fitting required for size 80 to 150 mm dia |
| 71 | Fitting required for size 200 to 300 mm dia |
| 72 | Fitting required for size 400mm dia |
| 73 | Material and labour for construction of Brick Masonry Valve Pit, one Brick thick wall (sub class 'B' bricks) in cement mortar 1:4 on 100mm thick PCC 1:4:8 type D2(40mm graded stone aggregate) in Foundation, Rendering 15 mm thick in CM 1:6 internally and externally upto 150mm below GL, providing 3.0mm thick MS Sheet Valve Pit Cover, welded with 40X5mm Flat Iron Frame alround including provision of Hinges, Handle and Locking Arrangement and 40 x 40 x 6mm Angle Iron Frame fixed on Top of Valve Pit by means of Holdfast 150mm long, embedded in PCC 1:2:4 type B1 (20mm graded stone aggregate) Block of size 230 x 200 x 100 mm, applying two coats of Anti-corrosive Paint over a coat of Red Oxide Zinc Chrome Primer after preparation of all exposed Steel Surfaces including necessary Earth Work in Soft/Loose Soil and demolition of old unserviceable Valve Pit of following sizes complete all as specified and directed. |
| 74 | 900 x 900 x 900 mm (Internal Dimension) |
| 75 | 600 x 600 x 600 mm (Internal Dimension) |
| 76 | Material and labour in repair of existing Brick Masonry Valve Chamber, with brick work with sub- class 'B' brick in one brick thick wall in cement mortar 1:4 including Rendering of Cement plaster 10 mm thick internally and externally with Cement motor 1:6 complete all specified and directed. |
| 77 | Material and labour in repair and repacement of existing Brick Masonry Valve Chamber cover of any size and discription with and including MS Sheet Cover 6 mm thick, welded with 40 x 5 mm Flat Iron Frame alround including provision of Hinges, Handle and Locking Arrangement and 40 x 40 x 6 mm Angle Iron Frame fixed on Top of Valve Pit by means of Holdfast 150mm long, embedded in PCC 1:2:4 type B1 (20mm graded stone aggregate) Block of any size, applying two coats of Anti-corrosive Paint over a coat of Red Oxide Zinc Chrome Primer after preparation of all exposed Steel Surfaces and demolition of old unserviceable Valve Pit cover of any size complete all as specified and directed. |
| 78 | Material and Labour for mechanical joint consisting of compression collars made out of Cast Iron, MS Flanges drilled as per IS for pressure rating PN1.6, including MS nuts, bolts, rubber gasket,cleaning the pipe surface,chamfering or cutting the edges of pipes for positioning, jointing and testing for the following size and of pipe material GI/CI/MS, and taking down old unserviceable machanical joint complete all as specified and directed by Engr-in-charge. |
| 79 | 400mm bore |
| 80 | 300mm bore |
| 81 | 200mm bore |
| 82 | 150 mm bore |
| 83 | 100 mm bore |
| 84 | 80 mm bore |
| 85 | Taking down Mechanical actuator held from existing position and refixing the same after servicing in specified location including checking & laying the supply cable testing complete all as specified and directed by Engineer in Charge |
| 86 | Supply and fix MS Pipe conforming to IS : 1239 of sizes 300 mm dia and 8 mm thick laid in trenches/ floor including bend, elbow, and Tee flanges cutting welding and necessary nut nolts required for fixing the pipe in location,including taking down old unserviceable complete all as specified and directedNote: Cost of pipe are inclusive with BEND, TEE, Tee equal, reducer etc. |
| 87 | Ditto-- as same as Item No. 20 for 250 mm dia |
| 88 | Ditto-- as same as Item No. 20 for 200 mm dia |
| 89 | Ditto-- as same as Item No. 20 for 150 mm dia |
| 90 | Ditto-- as same as Item No .20 for 100 mm dia |
| 91 | Ditto-- as same as Item No.20 for 80 mm dia |
| 92 | Taking down unserviciable and Material and labour for fabrication/structural work with mild steel sheet angle iron , MS Pipe in any shape or size as indicated framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc..all as directed and including welding/ bracing, painting with one coat of red oxide primer and two coat of black paint (one coat before fixings and one coat of black paint after fixing ), Fe-290 Grade E-165, complete all as specified and directed. |
| 93 | Material and Labour for PCC 1:3:6 ,Type C1, using 20mm graded stone aggragate for foundations, filling and mass concrete complete all as specified and directed. |
| 94 | Material and labour for cement concrete interlocking tiles 60 mm thick in floor/pavement laid over and including 30 mm thick stone dust/sand cushioning laid dry to profile complete all as specified and directed by Engineer-in-Charge |
| 95 | Supply and fix High strength free flowing solid chlorination medium fortified with corossion inhibitors and anti scaling agent for drinking water application. Minimum chlorine strength 55%. OEM claim regarding corossion inhibitors and anti scaling agent content must be ratified by E-in-C branch (Copy of E-in-C branch letter must be submitted to qualify for bid/tender). |
| 96 | Labour only for for attending the emergency repairs to leakage/damage CI/DI pipe of 300/400 mm dia either in night or in any holiday, running between Aundh military complex to west side pump house at MH complex of Range Hills including carrying out major repairs to the leakage/breakage etc as required to make the system in order / functional and necessary excavation ,returning , filling of soils and removal of water by using pump, cutting and jointing with new fittings as required at site complete all as specified and directed by Engr-in-charge.Note (i) Rate inclusive of earth work by means of JCB machine. (ii) Jointing materials if required will be measured in kg under seperate items in this schedue. |
| 97 | All as per item No. 30 for dia Pipe Size 80/ 100/150/200 mm complete all as specified and directed. |
| 98 | Labour only for attending the repairs for leakage/damage GI Pipe of Size 15/20/25/40/50 mm dia either in night or in any holiday, running between Aundh military complex iincluding carrying out major repairs to the leakage/breakage etc as required to make the system in order / functional and necessary excavation ,returning , filling of soils and removal of water by using pump, cutting and jointing with new fittings as required at site complete all as specified and directed by Engr-in-charge.Note (i) Rate inclusive of earth work by means of JCB machine. (ii) Jointing materials if required will be measured in kg under seperate items in this schedue. |
| 99 | Supply and fix in repair Ball brass valve, high pressure with polythene float and fly nut complete ISI marked of following size, complete all as specified and dircted by Engineer-in-Charge. |
| 100 | 50 mm bore |
| 101 | 40 mm bore |
| 102 | 25 mm bore |
| 103 | 20 mm bore |
| 104 | 15 mm bore |
| 105 | Testing of treated water as per norms / standard raw sewage characteristics from Govt approved laboratory complete all as specified and directed by Engineer in charge.Note - Contractor shall collect water sample from treated water tank of STP twice in a month for testing of treated water from Govt approved agency and report shall be submitted to Engineer in charge |
| 106 | Supply and fix in repairs following capacity six layer, White in colour, ISI Mark, rotational moulded, polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc complete all as specified and directed. |
| 107 | 500 Ltrs |
| 108 | 1000 Ltrs |
| 109 | 2000 Ltrs |
| 110 | Dismantling the water meter (any make) of size 300mm dia for repairs/ calibration from its position and inserting a flange of same size and length, transporting to civil workshop / Laboratory for replacing the wornout spares and calibration testing from MIDC and transporting back to site, refixing the same on existing position with rubber gaskets, testing for leakages complete all as specified and directed. Note: Test certificate shall be obtained from testing officer of MIDC and submitted to Engr- in -charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender