Defence Statutory Bodies & Commissions/Committees Closing in 1 days TDR #57942052

Tender For Repair/Maint And Replacement Of Lt Ug Cables, Acbs/Mccbs, Repair/ Maintenance Of Lt Panel Boards/ Feeder Pillar, Apfc Panels Etc. Incl Comprehensive Maintenance Of Apfc Panel And Connected Works At Sma Rameswaram Under Ge Fort Kochi

Issued by Statutory Bodies & Commissions/Committees · Ernakulam, Kerala
Tender Value
14.75 Lakhs
Estimated cost
Bid Submission
10 Nov 2026
1 days left
EMD
29500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ernakulam → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maint And Replacement Of Lt Ug Cables, Acbs/Mccbs, Repair/ Maintenance Of Lt Panel Boards/ Feeder Pillar, Apfc Panels Etc. Incl Comprehensive Maintenance Of Apfc Panel And Connected Works At Sma Rameswaram Under Ge Fort Kochi

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 29-Oct-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 05-Nov-2026
2 05-Nov-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 10-Nov-2026

BOQ

Name of Work:- REPAIR/MAINT AND REPLACEMENT OF LT UG CABLES, ACBs/MCCBs, REPAIR/ MAINT OF LT PANEL BOARDS/ FEEDER PILLAR, APFC PANELS ETC. INCL COMPREHENSIVE MAINT OF APFC PANEL AND CONNECTED WORKS AT SMA RAMESWARAM UNDER GE FORT KOCHI
Sl. No. Item Description
1Material and Labour for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.3 mm thick buried directly in ground earth pit not less than 2.25 M deep below ground level with top edge of the plate not less than 1.5 M below normal ground level connected to galvanised strip of 25x4 mm by means of nuts, bolts, check nuts, washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part I of 2009 connected to earthing test point or disconnecting / testing link including excavation/ earth work in any strata, removal of surplus earth, GI pipe medium grade 20 mm for watering and funnel, GI Pipe light grade 40mm dia for earth lead protection, PCC 1:3:6 type C1 chamber with chamber cover in RCC 1:2:4 type B1 and taking down of existing earthing, complete all as specified and as directed.
2Excavation in trenches not exceeding 1.50m wide and not exc 1.5m depth for foundation, laying of UG cables etc or for shafts, wells, cesspits, manholes, pier holes etc not excluding 10 Sqm on plan in hard/dense soil and getting out, complete all as specified and as directed.
3Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm in any type of soil complete all as specified and as directed.
4Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point. complete all as specified and as directed.
5Material and labour for sand cushioning to the full width of trenches for protection of cables including spreading and punning down including watering consolidation complete all as specified and as directed. Note: Punned thickness of riddled earth shall be measured and paid after cushioning.
6Supply and lay sub class B burnt bricks as in cable protection, laid length of brick perpendicular to length of cable complete, all as specified and as directed.
7Disconnecting and taking out old defective LT UG cable/ aluminium conductor of any size/type from trenches/ walls/ poles/ pipes complete, all as specified and as directed.
8Supply, laying, jointing, connecting, testing underground XLPE insulated, PVC sheathed, armoured heavy duty electric LT cable,1100volts grade with aluminium stranded conductor,10sqmm 4 core, laid in trenches/fixed to poles/drawn through pipes with suitable size cable glands, crimping type cable lugs, sockets etc. and taking down the existing cable complete all as specified and as directed.
9`-Ditto- all as per item No 8 but cable of size 16 Sqmm 4 Core all as specified and as directed.
10`-Ditto- all as per item No 8 but cable of size 25 Sqmm 4 Core all as specified and as directed.
11`-Ditto- all as per item No 8 but cable of size 35 Sqmm 3.5 Core all as specified and as directed.
12`-Ditto- all as per item No 8 but cable of size 50 Sqmm 3.5 Core all as specified and as directed.
13`-Ditto- all as per item No 8 but cable of size 70 Sqmm 3.5 Core all as specified and as directed.
14`-Ditto- all as per item No 8 but cable of size 95 Sqmm 3.5 Core all as specified and as directed.
15`-Ditto- all as per item No 8 but cable of size 10 Sqmm 2 Core all as specified and as directed.
16`-Ditto- all as per item No 8 but cable of size 120 Sqmm 3.5 Core all as specified and as directed.
17`-Ditto- all as per item No 8 but cable of size 150 Sqmm 3.5 Core all as specified and as directed.
18`-Ditto- all as per item No 8 but cable of size 185 Sqmm 3.5 Core all as specified and as directed.
19`-Ditto- all as per item No 8 but cable of size 240 Sqmm 3.5 Core all as specified and as directed.
20Supply and laying PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, conforming to IS 694 of size 2.5 Sqmm 2 Core complete including taking down old cable complete all as specified and as directed.
21Supply, laying and fixing in replacement 100mm bore GI pipe light grade for necessary road crossing, culverts etc for cable protection complete all as specified and as directed.
22Supply, laying and fixing in replacement 50mm bore GI pipe light grade for necessary road crossing, culverts etc for cable protection complete all as specified and as directed.
23Supply, laying and fixing 40mm bore in replacement GI light grade for necessary road crossing, culverts etc for cable protection complete all as specified and as directed.
24Supply and fix in replacement outdoor type FRP junction box of size 300x200x105mm, light weight suitable for pole mounting using clamps/bolts and nuts including MCB SP 6 Amps single pole including necessary connector for loop in loop out cable connection complete all as specified and as directed.
25Supply and fix in replacement outdoor type FRP junction box of size 140x140x105 mm, light weight suitable for pole mounting using clamps/bolts and nuts including MCB SP 6 Amps single pole including necessary connector for loop in loop out cable connection complete all as specified and as directed.
26Supply and fix in replacement 25 x 4 mm GI strip as earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required complete all as specified and as directed.
27Material and labour for painting on old surfaces of LT panel any type any size by spray paint after cleaning strains and grease/oil spots with sand paper & thinner and painting the cleaned surface with synthetic enamel paint of existing colour to achieve good finish by applying two coats of paints by spray painting machine carefully after disconnection the power supply and covering the meters, indicators and switches to prevent from fall of paint drop on them all as specified and as directed.
28Supply and jointing as in repairs straight through joint, outdoor type 1100 volts grade, heat shrinkable type suitable for 3.5 core, 240 Sqmm to 300 sqmm LT, XLPE cable and testing after jointing complete all as specified and as directed.
29`-Ditto- all as per item No.28 above but straight through joint suitable for size of 3.5 core, 150 Sqmm to 185 sqmm LT, XLPE cable.
30`-Ditto- all as per item No.28 but straight through joint suitable for size of 3.5 core, 70 Sqmm to 120 sqmm LT, XLPE cable.
31`-Ditto- all as per item No.28 but straight through joint suitable for size of 3.5 core, 25 Sqmm to 50 sqmm LT, XLPE cable.
32`-Ditto- all as per item No.28 but straight through joint suitable for size of 2/4 core, 10 to 16 Sqmm LT XLPE cable.
33Supply and jointing in repairs end termination, outdoor type 1100-volts grade heat shrinkable type suitable for 70 to 120 Sqmm LT XLPE 3.5 core cable and testing after jointing complete all as specified and as directed.
34Supply and jointing in repair end termination, outdoor type 1100-volts grade heat shrinkable type suitable for 240 to 300 Sqmm LT XLPE 3.5 core cable and testing after jointing complete all as specified and as directed.
35Supply and fix in replacement of aluminium crimping type lugs of size 10 Sqmm to 25 sqmm complete all as specified and as directed.
36Supply and fix in replacement of aluminium crimping type lugs of size 35 sqmm to 50 sqmm complete all as specified and as directed.
37Supply and fix in replacement of aluminium crimping type lugs of size 70 sqmm to 95 sqmm complete all as specified and as directed.
38Supply and fix in replacement of aluminium crimping type lugs of size 120/150/180 sqmm complete all as specified and as directed.
39Supply and fix in replacement of aluminium crimping type lugs of size 240/300 sqmm complete all as specified and as directed.
40Material and labour for detecting cable fault of size up to 240Sqmm LT, XLPE cable by means of fault-finding machine/ manual including excavation or earth work if required at site complete, all as specified and as directed.
41Material and labour for PCC (1:3:6), Type C-1, (using 20 mm graded stone aggregate) as in coping and the like including weathering, slightly rounded or chamfered angles and throating including formwork [straight or curved] complete all as specified and directed.
42Material and labour for repairing the existing LT Panel/ feeder Pillar Box any type or size by taking proper shutdown, disconnecting and reconnecting cables, welding/drilling for smooth functioning of panel door, locking arrangement complete all as specified and as directed.
43Supply and fix in replacement 3 phase VAF + PF meter type having accuracy class 1, range up to 50-400 Amps with selectable CT secondary site 1A/5A, complete, all as specified and as directed.
44Supply and fix in replacement indicating lamps LED type set (R, Y, B) complete, all as specified and as directed.
45Supply and fix in replacement selector switch complete, all as specified and as directed
46Supply and fix in replacement CT Coil suitable 250/5A for different load all complete, as specified and as directed.
47Supply and fix in replacement spreader terminals suitable for MCCB of capacity 200A to 250A complete, all as specified and as directed.
48Supply and fix in replacement of Analog timer switch programmable with 16A current carrying capacity suitable for mounting on DIN rail complete all as specified and as directed.
49Supply and fix in replacement of 4 pole contactor 250 A 2 NO +2 NC complete all as specified and as directed.
50Disconnecting the existing unserviceable MCCB from panel board after disconnecting cable and supply & fix new MCCB 63A, 4 Pole, 16 KA, adjustable, fixed in existing panel including modification of existing frame and panel board door for proper installation of MCCB and connecting with existing cable including thimble, nut bolt and washers etc. complete, all as specified and as directed.
51`-Ditto- all as per item No 50 above but of 100A, 4 Pole, 16 KA all as directed and as specified.
52`-Ditto- all as per item No 50 above but of 100A, 3 Pole, 16 KA all as directed and as specified.
53`-Ditto- all as per item No 50 above but of 125A, 4 Pole, 16 KA all as directed and as specified.
54`-Ditto- all as per item No 50 above but of 160A, 3 Pole, 16 KA all as directed and as specified.
55Disconnecting the existing unserviceable MCCB from panel board after disconnecting cable and Supply & fixing new MCCB 200A, 25 KA 4 Pole fixed in existing panel including modification of existing frame and panel board door for proper installation of MCCB and connecting with existing cable including thimble, nut bolt and washers etc complete, all as specified and as directed.
56`-Ditto- all as per item No 55 above but of 250A, 4 Pole 25 KA all as directed and as specified.
57`-Ditto- all as per item No 55 above but of 400A, 4 Pole 25 KA all as directed and as specified.
58Cleaning and maintaining of surrounding areas of LT panel by cutting bushes/plants including internal cleaning throughout the contract, etc all as specified and as directed.
59Supply and fix in repairs Rotary handle suitable for MCCBs of capacity up to 630 Amps all as specified and as directed
60Material and labour for replacement of all internal wiring in 290 KVAR capacity APFC panel board of Make: ABB using colour-coded FRLS copper wires, properly linking all contactors, capacitors, voltmeters, ammeters, MCCBs, indicators, and incoming/ outgoing power supply, including neat arrangement, secure fixing, and testing for proper operation, all as specified and as directed. Note: Power contactors, capacitors, ammeters, and voltmeters shall be measured and paid separately.
61Material and labour for comprehensive maintenance of 08 Nos Automatic Power Factor correction capacitor banks, 40 to 290 KVAR including repair/replacement of defective/un-serviceable parts during maintenance period, attending to breakdown as and when it occurs, necessary periodical checking twice in a month and testing of capacitor banks as per manufacture's instruction for smooth and efficient functioning of capacitor panels, installed at various Sub Stations and Power Houses. Note: - Spare parts shall be measured and paid separately.
62Notes: -(i) The Power Factor should always be maintained more than 0.95.(ii) If the Power Factor comes below 0.95 up to 0.90, a penalty of Rs.1000.00 per HT connection will be recovered from the payment.(iii) If KSEB imposes any penalty due to low power factor than 0.90 then double the amount will be recovered from the contractor as penalty for non-functioning of panel.(iv) The rate quoted shall be deemed to be included the charge for taking out defective spares & fixing of new spares and tightening of cables & accessories etc.(v) Cost of spares required for replacing shall be measured and paid separately.(vi) 2 jobs x 11 Months = 22 Jobs (The above job shall be carried out and measured 2 times per month for entire installation at SMA Rameswaram
63Supply only 10 KVAR Capacitor, HD Gas filled cylindrical, 3 phase, 440 Volt AC having low watt loss of not less than 0.5 W/KVAR all as specified and as directed.
64Supply only 25 KVAR Capacitor HD Gas filled cylindrical, 3 phase, 440 Volt AC having low watt loss of not less than 0.5 W/KVAR all as specified and as directed. Make L&T Cat Part: - LTCCN325B2/ equivalent as approved by GE.
65Supply only 12.5 KVAR Capacitor box type Heavy Duty, 3 phase, 440 Volt AC having low watt loss of not less than 0.5 W/KVAR, all as specified and as directed.Make- ABB/ equivalent as approved by GE
66Supply only volt meter suitable for 290 KVAR APFC Panel board, Voltage Range Up to 750V AC, accuracy Class 1.5 suitable for existing make MECO-G S196 all as specified and as directed.
67Supply only Contactor for 12.5KVAR Rating capacitor switching, all as specified and as directed. Make: ABB Cat part No. UA16-30-10RA / equivalent as approved by GE.
68Supply only Contactor for 20 KVAR Rating capacitor switching, all as specified and as directed. Make: ABB Cat part No. UA26-30-10RA / equivalent as approved by GE.
69Supply only Contactor for 25 KVAR Rating capacitor switching, all as specified and as directed. Make: ABB Cat part No. UA30-30-10RA / equivalent as approved by GE.
70Supply only Microprocessor based APFC relay, 14/12 stage, all as specified and as directed. Make: L&T / Siemens / ABB / Shneider
71Supply only flush head 230 Volt AC Push Button, all as specified and as directed.
72Supply only Amp Meter suitable for 290 KVAR APFC Panel, all as specified and as directed. Make: - Schneider Electric Conzerv DM1110 / equivalent as approved by GE.
73Supply only MCCB 630Amps, 3 pole, 35kA at 415Volt, all as specified and as directed. Make ABB, SACE S5N / equivalent as approved by GE Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57942052
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 14.75 Lakhs
LAST DATE 10-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint And Replacement Of Lt Ug Cables, Acbs/Mccbs, Repair/ Maintenance Of Lt Panel Boards/ Feeder Pillar, Apfc Panels Etc. Incl Comprehensive Maintenance Of Apfc Panel And Connected Works At Sma Rameswaram Under Ge Fort Kochi
Basic Detail
Tender No 8425/E8_GE_FORT_KOCHI
Bidding Type Tender
Location
City Ernakulam
State Kerala
Key Dates
Publish Date 05 Nov 2026
Submission Date 10 Nov 2026
Open Date 17 Nov 2026
Finance
Tender Value 14.75 Lakhs
Tender Fee 500
EMD 29500
Exemption Available
Document List
8425Tenderdocu.pdf
b3fb94d9-71c4-44fe-804f-7aea8c95a414.html
BOQ_888997.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 05, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Nov 10, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 1 day
Nov 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Nov 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
pdf

8425Tenderdocu.pdf

html

b3fb94d9-71c4-44fe-804f-7aea8c95a414.html

xls

BOQ_888997.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender