Tender For Repair/Maintenance Of Sub-Station, Pump House And E/M Installation Of Area A, B & C At Naval Dockyard Visakhapatnam Under Ge(I) Dm Visakhapatnam

Issued by Statutory Bodies & Commissions/Committees · Visakhapatanam, Andhra Pradesh
Tender Value
49 Lakhs
Estimated cost
Bid Submission
29 Oct 2026
17 days left
EMD
98000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Visakhapatanam → Andhra Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maintenance Of Sub-Station, Pump House And E/M Installation Of Area A, B & C At Naval Dockyard Visakhapatnam Under Ge(I) Dm Visakhapatnam

BOQ

Name of Work:- REPAIR/MAINTENANCE OF SUB-STATION, PUMP HOUSE AND E/M INSTALLATION OF AREA A, B & C AT NAVAL DOCKYARD VISAKHAPATNAM UNDER GE(I) DM VISAKHAPATNAM
Sl. No. Item Description
1Taking down exising steel rolling shutter incl hood cover pull and push type, n exc 5 sqm area of sides of clear opening and cleaning the sides of shutters suspension shafts, anti-guide channel and gearing all the moving parts rolling shutters and strengthening rolling shafts and replacement of bolts and nuts as required for smooth functioning of shutters and refixing the same including hood cover complete all as specified and directed.
2All as per item No. 1.00 above, but gear operated type rolling shutters exc 5 sqm but nexc 15 sqm area and incl adjustment of gear assembly complete .
3Repairs and servicing to rolling shutters by removal of wornout components such as hood covers, laths, ball bearing, helical wire springs, lock plates, shaft pipes and straightening of existing guide channels, laths, hood covers at required places including greasing and servising, refixing in the same openings complete all as specified and directed.
4S&F in repairs steel rolling shutters of 1.25mm thickness of lath, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete with gear operated type with bevel gear box and crank handle all as specified and directed.
5S&F in repairs electrically operated, 1.15mm thick steel rolling shutters, area exc 15 sqm, with chain bearing wheel,and quide channels with out ball baring, as specified including top cover anchoring rod, hasp and staple, shaft, pipe, brackets, and one shop coat of primer, erected in position with chain wheel and hand chain of suitable length to operate complete all as specified and directedNote:- Electric motor measured and paid separately under relevant item.
6S&F Electric motor of weighing capacity upto 300 kg and power upto 3.70 Watt for rolling shutter including all necessary fitting complete of Make Jielong or equivalent make as approved by GE (I) DM all as specified and directed.
7Material and labour for preparation of steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
8S&F in repairs ball bearing for rolling shutters complete all as specified and directed.
9Material and labour for preparation of old painted steel surfaces of any description over 10 cm width or girth and applying one coats of aluminium paint complete all as specified and directed.
10S&F in repairs mild steel lock plate & handles made out of MS flat iron 40x5mm incl welding (lock plate & handle should be replace of old damaged lock plate) and painting with two coats of synthetic enamel paint over a coat of zinc chromate primer complete all as specified and directed.
11S&F in repairs mild steel helical wire springs (conforming to IS-6248-1970) for rolling shutters not exc 15 sqm complete all as specified and directed.
12All as per item No. 11.00 above, but for shutter exc 15 sqm but not exc 30 sqm complete
13S&F in repairs MS gear box assembly complete including connecting and fixing the gear box to wall with 4 Nos hexagonal bolts of 10mm dia and 100mm long complete including cutting into existing wall/pillar of brick work/RCC and filling back with PCC complete all as specified and directed.
14S&F in repairs hood covers made out of mild steel sheets 0.90 to 1.00mm thick incl bending the sheet to the required shape and fixing the same to the rolling shutter bracket plate incl one coat of zinc chromate primer and two coats of synthetic enamel paint complete all as specified and directed.
15S&F in repairs mild steel pully for 32/40mm dia pipe ( of approved make) for rolling shutters complete all specified and directed.
16Supply only MS gear handle(of approved make) for gear operated rolling shutters of suitable size complete all as specified and directed.
17S&F in repairs inter locking lath section formed from rolled MS strips 1.25mm thick for shutters of any width complete all as specified and directed.
18S&F in repairs MS wheel fitted with ball bearing and clip axle rod with spring washer and nut including welding and gas cutting complete for sliding door weighing 10kg each to make smooth movement complete all as specified and directed.
19M&L for straightening of bent / dented portion of sliding door including necessary welding complete all as specified and directed.
20M&L for greasing the top and bottom guide rails of MS sliding door for smooth opening complete all specified and directed.
21M&L for guide pins of sliding door, removing the existing worn out pins and replace by new one including painting with two coat of aluminum paint over a coat of zinc chromate primer complete all as specified and directed.
22Repairs to collapsible gate removal and replacement of worn out minor parts such as rivets, rollers whets, straightening of vertical channels and cleaning of rust including greasing and re fixing the same in position complete all as specified and directed.
23S&F in repairs collapsible steel Gates top hung or bottom rest , consisting of channel pickets pivots flats bars top and bottom runners , brass handle etc. erected in position and securing runners with hold fasts and bracket complete all s specified and directed.
24Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) as in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed.
25M&L for RCC type B1 1:2:4 (20 mm graded aggregate) Reinforced cement concrete (nominal mix) in slab, Chjja and like work complete all as specfied and directed
26M&L for form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) all as specified and directed.
27M&L for MS TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia as reinforcement complete all as specified and directed.
28Demolition of brick work or stone / boulder masonry built in cement mortar including removal of debries outside of Dockyard premises complete all as specified and directed.
29M&L for Pre cast cement concrete type 1:3:6 type C-1 (20mm graded stone aggregate) block masonry with solid blocks exc 10 cm in width and setting in cement mortar 1:4 complete all as specified and directed.
30Demolition over Roof, Backup Materials (Roof tiles, Tiles Backup Materials, Screed, APP Membrain, Bituminus Primer, PCC pading & Rought Plaster and Cleaning the surface of the slabs, making it absolutely free from dust, oil or any type of deleterious materials etc by mechanical grinding, and chipping off the loosely adhesive mortar. The cleaning and preparation of the RCC surface must be carried out throughly to leave a sound base for the application of the primer, use of surface grinder is must. If any surface crack observed that should be cut \\"V\\" groove & should be packed with Fosroc Nitobond or equivalent SBR Latex polymer modified mortar @ 10% by weight of cement of Cementatious Grouting done with Forsorc or equivalent Cebex 100 @ 225 Gram pkt per 50 Kg bag of cement. All hairline cracks shall be chased to a 6mm x 6mm groove and filled using Fosroc Nitocote VF or equivalent including removal of waste material/Debris away from the Dockyard premises complete all as specified and directed.
31M&L for covering Junctions between walls and bottom of the slab and peripheries shall be followed by providing a triangular fillet by 50mm x 50mm size. Groove cutting at all joints with a size of 20mm x 20mm. Roughen the wall floor junction with wire brush and remove loose and dirt particles with the air blower. Apply a bonding coat of Fosroc or equivalent Nitobond SBR Latex and cement by volume on cleaned RCC surface by brush taking care to avoid pinholes. Making angle fillet (Hallore/Galta) within 10 minutes of bond coat application. Prepare PMM by taking 5L of Nitobond SBR Latex, 50 kg cement, and 150 kg sand. (i.e., in the ratio of 0.1:1:3) on RCC surface (slab and wall junction) finishing in smooth finish. Add the required amount of water to achieve a dough-like consistency, allowing it to be hand-packed effectively.
32M&L for Providing necessary formwork for packing the bore using suitable arrangement (depending upon site conditions). Bore packing of sleeves & drain water pipes to be done using free flow non-shrink grout Fosroc Conbextra GP2 or equivalent for a minimum width of 10-20mm all around the sleeves by placing a leak-proof shuttering all around and then sealed with epoxy putty Fosroc Nitocate VF or equivalent.
33M&L for Prime the surface with Fosroc Nitoproof WB or equivalent primer for priming concrete surfaces prior to the application of liquid applied water proofing coatings the diluted primer should be applied at a coverage of 8-10 Sqm/litre, preferably using roller. The applied primer should be allowed to reach tack free condition before applying liquid applied coatings and membranes. After completing the primer, providing and carrying out waterproofing treatment liquid applied single component pitch free polyurethane coating capable of bridging substrate cracks up to 2mm.
34Item No. 33.00 Contd../-Poviding and Applying Forsroc Nitoproof 600PF or equivalent chemicals a single component pitch free polyurethane-based coating. It is elastomeric, seamless waterproof membrane applied in 2 coats to DFT not less than 1.5mm thick @ 2.5 kg per sqm having a elongation capacity of over 400% and primer to be applied. Termination to be done on wall extending the coating to min 300mm height above the finished floor level and sealed inside the groove of 20mm wide x 10mm thick flushed with polymer modified. Laying 150 Geo Textile (Non-woven NP Fibric) on the entire waterproofing treated surface with overlapping 100mm each, overlap sealed using synthetic rubber adhesive. This cloth making a separation layer between waterproofing and screed concrete complete all as specified and directed.
35Providing and applying protective screed of aversge 50 mm thickness on treated waterproof area. The concrete shall be admixed with Fosroc Conplast Wlxtra @ 200 ml/ Fosroc Conplast Crystalline @ 400 gm/ bag of cement, compaction, finishing surface suitably, curing, cleaning, testing etc. Paneling & groove 10mm X 6mm (Fosroc PU50) with paneling 3 Mtr X 2 Mtr complete all as specified and directed.
36M&F for fixing injection grouting nozzle of suitable size and for Injection grouting for structural cracks with low viscous epoxy resin Conbextra EP10M manufactured by M/s Fosroc chemicals and grouting by injecting the same using an electrically operated pressure grouting Machines until the nipple refuses the grout or the grout come out of a nearby nipples. (The base and the hardener of the epoxy resin come in pre weighed and pre-packed forms and hence should not be part mixed. The entire base and hardener shall be poured in a suitable container and mixed mechanically using a slow speed heavy duty drilling machine fixed with mixing paddles). After grouting, all the nipples shall be cut and the surface shall be finished to match the nearly surface. All the Procedures to be carried out by Manufacturer detailed specifications.Note : Conbextra EP 10 M chemical can be measured and paid separately.
37Supply only injecting grouting material ,low viscosity epoxy based grouting material Conbextra EP10 complete all as specified and directed.
38S&F Hard drawn steel wire fabric fixed to RCC components with necessary fixing arrangement weight n. exc 3.20 Kg/sqm but not exc 4Kg/Sqm complete all as specified and directed. .
39Material & labour for chipping (30mm to 75mm) of existing damaged, crakced, spalled & loose portion of concrete of the RCC members completely till the reinforcement is exposed and sound concrete is observed by using mechanical means and manual chisels and further the surface is cleaned with water jet, again clean the surface with blower to remove all loose fine particles present in the surfaces and for removal of dust and loose particles including hoisting assembling and fixing of double layer steel scaffolding complete all as specified and as directed.Note:-(a)Removing rubbish off the premises and disposting at outside ND land no seprate paid. (b) Work shall be carried out at any location or height i.e. Hills etc cost of the work deemed to be included in items.
40M&L for preparation of exposed surafaces of rusted steel reinforcement with metal wire brush , cleaning the rusted surfaces free from loose rust and application of rust remover cum passivator painted with brush to the rusted reinforcement , and removing rust with flex after 24 hours of application of rust remover with the help of wire brush, sand paper and thoroughly washed with water with the help of pressure jet and allowing it to dry complete all as specified and directed.( Length of cleaned reinforcement steel bar shall be measured for payment.)
41M&L for preparation of surfaces of steel of reinforcement by cleaning thruoghly and providing, mixing and applying zinc anti-rust agent as per manufacturers method of application to rebar corrosion protection system to reinforcement Fosroc or equivalent in M/S Sika India Pvt. Ltd. / M / S Choksey Chemicals Pvt. Ltd. / M/S Mapei Const Product India Pvt Ltd. / M/S THermax Ltd / M/S STP / M/S Dr Sunanada / M/S BASFor any other approved manufacturer of E-in-C's branch @3.75Kg/Sqm surface of steel reinforcement in two coats complete all as specified and directed.
42M&L for introducing new reinforcement bars of 12mm dia and above for structural connection in RCC beams, columns, lintel and slabs including power drilling holes of appropriate diameter in RCC to a minimum depth 150mm and upto 200mm, including power drilling, fixing the reinforcement in position using, cleaning of loose dust by blowing air, sealing with epoxy cartridges etc all as specified and directed.
43Material & labour applying a coat of Polymer modified cementious bonding coat on the concrete surfaces with one part of Styrene Butadiene Rubber latex emulsion (SBR latex) manufactured by M/s Fosroc chemicals or equivalent in M/S Sika India Pvt. Ltd. / M / S Choksey Chemicals Pvt. Ltd. / M/S Mapei Const Product India Pvt Ltd. / M/S THermax Ltd / M/S STP / M/S Dr Sunanada / M/S BASFor any other approved manufacturer of E-in-C's branch with four parts of water and six parts of cement by weight. Coverage of SBR latex-0.25Ltr / sqm for one coat complete all as specified and directed.
44Material & labour for providing Shear connectors and Anchoring by drilling 16 mm dia holes up to depth of 100mm in concrete surfaces and fixing 10 mm dia TMT bars L shaped anchor rods as shear connectors by using Fosroc Lokfix chemical (Mix of base and hardener of the polyester resin) in defective concrete area of the slab / column / beams / chajjas / lintel etc or any other structural member as per site requirement after cleaning the drilled hole by using water jet and after drying clean the surface with blower to remove all loose fine particles present in the hole. The Mix of base and hardener of the polyester resin shall be prepared by thorough mixing of base & hardener by the help of spatula. After preparing the mix the holes shall be filled to a minimum depth of 1/3rd of the hole with the prepared polyester resin and the reinforced bar shall be inserted to full depth of hole and extra length of the reinforcement bar shall be bent into the concrete to maintain proper cover to the reinforcement complete all as specified and directed.
45M&L for supply, mixing and placement of micro-concrete cement base prepacked single component chloride free, sulphate free, non-shrink flow self compacting,ready to use after mixing in proportion of sika Rep Microconcrete or renderoc-RG of fosroc in required thickness as per manufacture's instruction and all as direction. (Renderoc-RG of Fosroc Makeor equivalent in M/S Sika India Pvt. Ltd. / M / S Choksey Chemicals Pvt. Ltd. / M/S Mapei Const Product India Pvt Ltd. / M/S THermax Ltd / M/S STP / M/S Dr Sunanada / M/S BASFor any other approved manufacturer of E-in-C's branch having a compressive strength of 50 MPA strength for reparing of RCC members like columns, Beams etc. complete all as specified and directed.
46Material & laobur for application of polymer modified reinstatement mortar in isolated places of repair works of RCC members with Rendroc S2 of M/s Fosroc make or equivalent in M/S Sika India Pvt. Ltd. / M / S Choksey Chemicals Pvt. Ltd. / M/S Mapei Const Product India Pvt Ltd. / M/S THermax Ltd / M/S STP / M/S Dr Sunanada / M/S BASFor any other approved manufacturer of E-in-C's branch having a compressive strength of 40 MPa complete all as specified and directed.
47M&L for applying of hingh efficiency polymeric base film forming curing agent/compound over concrete surface and maximum covarage area 5.0 sqm per litre as per manufactures instruction complete all as specified and directed.
48Taking down cement plaster on brick or concrete wall etc including racking out joint hacking for key, scrubbing down with water etc. complete all as specified and as directed.
49M&L for rendering 15 mm thick plaster in CM (1:4) using SBR latex emulsion @ 3% by weight of cement on brick or concrete surfaces of walls the surfaces even and smooth without using extra cement complete all as specified and directed.
50Supply only Liquid water proofing compound all as specified and directed.
51M&L rendering 10 mm thick in CM 1:4 on brick/concrete wall surfaces of any description, and finishing the surfaces even and smooth without using extra cement all as specified and directed.
52M&L rendering 5mm thick cement plaster 1:3 on fair faces of brick work or concrete surfaces of ceilings finished even & smooth(without using extra cement) all as specified and directed.
53M&L for preparation of new plastered surfaces of walls and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm diluted with water as per manufacturer instructions by using Airless spray technology machine with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr, the spray machine should be from reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and acccessories for applying paint in hard to reach areas and penetration of paint on the surface complete all as specified and directed.
54M&L for wall care puty of 2mm thick complete all as specified and directed.
55M&L for preparation of new plastered surfaces of wall and applying two coats of distemper oil emulsion over a coat of primer with 3mm thick wall care putty on wall by using airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface complete all as specified and directed.
56M&L for preparation of new plastered surfaces of ceiling and applying two coats of distemper oil emulsion over a coat of primer with 3mm thick putty by using airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface complete all as specified and directed.
57M&L for complete removal of existing treatment on ceiling of old surface and applying two coats of distemper oil emulsion by using Airless spray technology machine with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr, the spray machine should be from reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and acccessories for applying paint in hard to reach areas and penetration of paint on the surface complete all as specified and directed.
58M&L for preparation of old surfaces of wall and applying two coats of oil bound distemper using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface complete all as specified and directed.
59M&L for surface preparation of old walls surface and applying one coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over old surfaces by using Airless spray technology machine with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr, the spray machine should be from reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and acccessories for applying paint in hard to reach areas and penetration of paint on the surface complete all as specified and directed.
60Dismantling mild steel work of any description complete all as specified and directed.
61M&L for providing and fixing stainless steel (Grade 304) railing/Staircase/Access door made of hollow tubes, channel, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc ., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed.
62M&L for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks,manhole covers, duct covers and similar work con- forming to Fe.290.Gde-E-165 complete all specified and directed.
63M&L for Mild steel plates, plain or chequered, of grade Fe-410-W (Gde - E-250), 5mm thick or over in thickness in available size complete all as specified and directed.
64M&L MS rolled section of grade Fe-410-W (Gde - E-250), quality - A (beam, tee, angle channel or flat sections) as in roof trusses (framed), trussed purlins, crane gantries rails, and fastening and heavy bracket framing including distance pieces, cleats etc.including dismantling existing one complete all as specified and directed.
65S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified including dismantling existing one complete all as specified and directed.
66M&L for preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
67M&L for preparation of old painted steel surface over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
68Demolition of cement concrete in steps and pavings bedding not exceeding 15 cm thickness ( above ground level) etc and disposing off the debris out side naval Dockyard premises complete all as specified and directed.
69M&L for 25mm thick Plain Cement concrete (PCC) 1:2:4 type B- 0, (12.5mm graded aggregate) as in sub base, steps and pavings etc complete all as specified and directed.
70M&L for 50mm thick sand filling under floor or in foundation including watering consolidation complete all as specified and directed.
71M&L for machine pressed precast cement concrete interlocking paver block with grey cement and pigment any shape and size of 60mm thickness , M-35 graded laid over sand cushioning complete all as specified and directed.
72M&L for chequered cement concrete tiles with grey and any pigments area exc 0.09sqm but n.exc 0.16 sqm of 25mm thick, set, jointed and pointed in neat cement slurry in floors and incl cement screed 15mm thick in 1:6 all as specified and directed
73M&L for 40 mm thick Plain Cement concrete (PCC) 1:2:4 type B- 0, (12.5mm graded aggregate) as in sub floors, sub bases, and pavings etc complete all as specified and directed.
74M&L for Hard core of broken stone or boulders of gauge not exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
75S&F factory made UPVC white colour sliding window three track of area not exceeding 2.00 sqm each made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67 mm). Sliding mesh Sash (42mm x 57mm) sliding interlock (one vertical lenght in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2 + - 0.2mm thick galvanised steel frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware (Touch Lock of zinc alloyed (white powder coated ), steel roller system, stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. Note: the unit rate quoted by the contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose.
76S&F 4mm thick figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed.
77S&F in repairs stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless wire staples complete all as specified and directed.
78Taking up or down 20 mm bore steel water tubing and connections including cleaning for refixing or removal complete all as specified and directed.
79Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.
80S&F 20 mm dia (outer diameter of the pipe) CPVC pipes SDR 13.5 fittings on walls/ceiling or laying in floors complete all as specified and directed.
81Taking out PVC (SWR) soil waste and vent pipe of any size including all fittings etc complete all as specified and directed
82S&F 110 mm dia PVC (SWR) pipes single, socketed, in any length with rubber ring joints fixed to wall complete all as specified and directed
83S&F 20mm bore CPVC Male Brass Threaded Adaptor (MTA/ MBTA) ) complete all as specified and directed.
84S&F 20mm bore CPVC Female Brass Threaded Adaptor (FTA/ FBTA) complete all as specified and directed
85S&F 110 mm bore PVC (SWR) bend equal or unequal with oval access door complete all as specified and directed.PVC (SWR) all as specified and directed.
86S&F 15 mm dia pillar taps, cast copper alloy with capstan head, chromium plated, screwed down, high pressure with or without letter 'Hot' or Cold' with long screwed shanks and fly nuts screwed for iron pipes complete all as specified and directed including taking out old one complete all as specified and directed.
87S&F 15 mm dia bib taps, cast copper alloy fancy type, chromium plated with crutch or butterfly handle, screwed down screwed for iron pipe of for brass ferrule complete all as directed including taking down old one all as specified and directed.
88S & F in repairs fancy type chromium plated 15 mm bore Stop valves, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed.
89Supply & fix health faucet 15 mm bore brass chromium plated jet spray with CP pipe of 900 mm long and connector complete all as specified and as directed including taking down old one all as specified and directed.
90S&F looking 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed including taking down old one all as specified and directed.
91S&F vitreous China Wash Basin, white, flat back of size 550 x 400 mm including suitable size of CI brackets, brass chromium plated waste fittings 32 mm dia with long screw shanks and fly nuts, flange and bedded in red lead cement complete all as specified and directed including taking out old one all as specified and directed.
92S&F vitreous China, squatting pan, Orissa Pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) with CI trap of suitable size ( P or S type) including connection to trap and to flushing pipe, anti syphonic pipe etc complete including provision of lime concrete bedding & making good to floor complete complete all as specified and directed including taking out old one all as specified and directed.
93S&F 10 Ltr capacity PVC valveless syphonic action type flushing cistern low level white, with inlet, ball valve, float and handle including PVC flush pipe and brackets complete fixed in wall and floor to trap of WC as required and as directed including taking down old one all as specified and directed.
94S&F 15 mm dia PVC connections, 600 mm long with PTMT nuts of suitable size at two end complete all as specified and directed including taking out old one all as specified and directed.
95S&F tubular towel rail 20 mm dia brass chromium plated 'D' type 60 cm long between flange brass CP all as specified including taking down old one all as specified and directed.
96Dismantling existing unserviceable water tank of capacity exc 500 ltrs and n exc 1000 ltrs complete all as specified and directed.
97S & F rotational moulded polyethylene water storage 1000 ltrs. capacity tank (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed.
98Dismantling existing unserviceable water tank of capacity exc 250 ltrs and n exc 500 ltrs complete all as specified and directed.
99S & F rotational moulded polyethylene water storage 500 ltrs. capacity tank (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed. Please Enable Macros to View BoQ information
100S & F rotational moulded polyethylene water storage 500 ltrs. capacity tank (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57942034
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 49 Lakhs
LAST DATE 29-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maintenance Of Sub-Station, Pump House And E/M Installation Of Area A, B & C At Naval Dockyard Visakhapatnam Under Ge(I) Dm Visakhapatnam
Basic Detail
Tender No 8654/C/E8
Bidding Type Tender
Location
City Visakhapatanam
State Andhra Pradesh
Key Dates
Publish Date 08 Oct 2026
Submission Date 29 Oct 2026
Open Date 31 Oct 2026
Finance
Tender Value 49 Lakhs
Tender Fee 500
EMD 98000
Exemption Available
Document List
4a934759-91c4-4af1-bf69-c053e88e7592.html
8654Tender.pdf
BOQ_888956.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 08, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Oct 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
html

4a934759-91c4-4af1-bf69-c053e88e7592.html

pdf

8654Tender.pdf

xls

BOQ_888956.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders