Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Addition/Alteration And Special Repair To Bldg No. P-84 Beg & Centre Khadki Under Ge (Central) Khadki

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 23-Oct-2026 DATE CORRIGENDUM Date 10-Nov-2026

BOQ

Name of Work:- ADDN / ALTN AND SPECIAL REPAIR TO BLDG NO. P-84 BEG & CENTRE KHADKI UNDER GE (CENTRAL) KHADKI
Sl. No. Item Description
1B/R PORTON: Dismantling of existing puff paneling including asbestos cement (Corrugated,semicorrugated sheets in roof covering complete all as specified and as directed by Engineer -in-Charge
2S&F prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any color having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engineer -in-Charge. NOTE: roof sheet includes the wall clading of the bldg vertical sides
3S&F prepainted galvalume aluminium zinc coating GI based Plain steel sheet 0.50 mm thick of any color having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engineer -in-Charge. NOTE: the roof sheet includes the wall clading of the bldg vertical sides.
4S&F for 4mm dia galvanised steel wire mesh 150X100mm, fabricated to the required size and fixed to wall openings with angle supports complete all as specified and as directed by Engineer -in-Charge. Note : The angle shall be measured and paid separately
5S&F roof trusses (framed) trussed purlins crane gantries rails fastenings and heavy bracket framing (Beam,tee,angle,channel, or flat section) including distance pieces, cleats etc complete all as specified and as directed by Engineer -in-Charge.
6S&F mild steel for wind ties for roof including Securing bolts,including cutting tops to shape as directed, drilling holes and similar works conforming to Fe-290 Gde E-165 complete all as specified and as directed by Engineer -in-Charge.
7S&F Framed work such as grill,grating,etc with ends bars shouldered and or rivted,or forged into spikes framed guard bars: barred iron doors :ladders framed baluster: walk ways: railing framework of water tanks and similar works conforming to Fe-290 Gde E-165 complete all as specified and as directed by Engineer -in-Charge.
8Taking down/removing existing waterproofing treatment from RCC roof slab including removal of plaster bed below felt /membrane and disposal of the same to distance exceeding 50m but not exceeding 500m as and where directed and M&L for 10 mm thick screeding /rendering in cement mortar 1:3 on concrete roof surface ,using water proofing compound @ 3% by weight of cement ,surface finished even and smooth without using extra cement complete all as specified and as directed by Engineer -in-Charge. NOTE: Water Proofing Compund shall be measured and paid seprately.
9Supply only intergral water proofing compound complete all as specified and as directed by Engineer -in-Charge.
10M&L for Cutting out cracks to \\"V\\" section in existing roofs or terracing, cleaning out wetting grouting with cement and sand slurry 1:3 complete all as specified and as directed by Engineer -in-Charge.
11M & L for cleaning the plastered /concrete surface with wire brush and applying water proofing treatment as under complete all as specified and as directed by Engineer -in-Charge.(a) Apply a uniform coat of primer at 0.70 kg/sqm over cement plaster.(b) 3mm thick and weighing not less than 3.6 kg/sqm Atactic Polypropylene Polymer (APP) modifiedbitumen - based prefabricated five layer water proofing membrane reinforced with non woven polyestermatt black finished over compatible primer at 0.40 Ltr/sqm of density at 25 degree centigrade 0.87 -0.89 kgjlitre and viscosity 70-160 cps or cold sticker and torch application of membrane with 10 cm overlap both ways after necessary preparation of surface complete as per manufacturers instructions.(c) Apply two coats of bitumastic - aluminium paint over the membrane.
12Dismantling water tanks and remooving to store of capacity 4000 Ltrs complete all as specified and as directed by Engineer -in-Charge.
13S&F in repair three layer rotational moulded polyethylene water storage tanks of capacity 4000 Itr hoisted and fixed in position including 40mm ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed complete all as specified and as directed by Engineer -in-Charge.
14Taking down cement or cement lime plaster on brick or stone walls,ceilings etc. including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed by Engineer -in-Charge.
15M &L for 15 mm thick plastering in cement mortar 1:4 on external plaster finished the surfaces (upto any height) using 3% of WPC of weight of cement used or as per manufacturer instruction complete all as specified and as directed by Engineer -in-Charge.
16M&L for Preparation to new surface and applying finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 Itr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and as directed by Engineer -in-Charge.
17M&L for complete removal of existing treatment, preparing the surfaces and applying finishing walls © with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and as directed by Engineer -in-Charge.
18M&L for applying two coat of white wash on ceiling including preparation of old surfaces complete all as specified and as directed by Engineer -in-Charge.
19M&L for complete removal of existing finishes by scraping down old decorative surface of ceiling with steel wire brushes and removing smoke spots, moulds, efflorescent salts including filling of spots with POP, chalk whiting, priming and applying three coats of white wash on old surfaces of ceiling complete all as specified and as directed by Engineer -in-Charge.
20M&L for 15 mm thick rendering in cement mortar 1:6 on fair faces of brick work or concrete surfaces including finishing the surface with a thin layer of sagol complete all as specified and as directed by Engineer -in-Charge.
21M&L preparation of new plastered surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer over 0.5 mm thick sagol finish complete all as specified and as directed by Engineer -in-Charge.
22M&L for complete removal of existing treatment of any description on walls with steel wire brushes etc., and applying two or more coats Wall Care Putty having average minimum thickness of 0.5 mm on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of oil bound distemper over one coat of alkali resistant primer on walls complete all as specified and as directed by Engineer -in-Charge.
23M&L for preparation of new steel surfaces exc 10 cm width or girth and applying two coats of synthetic enameled paint over a coat of red oxide primer complete all as specified and as directed by Engineer -in-Charge.
24M&L for preparation of new steel surfaces of any description, n.exc 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide when unconnected with other painting or when painted in a different tint complete all as specified and as directed by Engineer -in-Charge.
25M&L for preparation of old steel surfaces exc 10 cm width or girth and applying one coat of synthetic enameled paint complete all as specified and as directed by Engineer -in-Charge.
26Taking up or down 20 mm bore steel tubing and connections including disconnection of fittings and cleaning for refixing where required complete all as specified and as directed by Engineer -in-Charge.
27All as above Item No. 26 but 40 mm dia pipe etc. complete all as specified and as directed by Engineer -in-Charge.
28S&F 20 mm bore of pipe medium grade steel tubes, galvanised with and including all fittings and fixed complete to concealed walls and ceilings or laid in floors complete all as specified and as directed by Engineer -in-Charge.
29S&F 40 mm bore of pipe medium grade steel tubes, galvanised with and including all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by Engineer -in-Charge.
30S&F in Gun metal globe or gate valves 40 mm bore with iron wheel head screwed both endsfor iron pipe and fixed in repair complete all as specified and as directed by Engineer -in-Charge.
31S&F in repairs 20mm dia bore gun metal globe or gate valves with iron wheel head,screwed both ends for Iron pipes and fixed complete all as specified and as directed by Engineer -in-Charge.
32Demolition of brickwork or stone and precast concrete block built in cement mortar complete all as specified and as directed by Engineer -in-Charge.
33E/M PORTION: Taking down copper/aluminium point wiring ( light, fan, socket, power ) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately ) and making good disturbed surface of walls, floors, etc
34Taking down carefully submain wiring any size
35Taking down old DBs and VTPN DBs any type.
36M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one light point or one fan/Ex fan point controlled by one, one way switch including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, regulators or bell push and casing caping terminal box for mounting ceiling rose/ holders etc all as specified and directed by Engr-in-Charge.
37All as per item No. 36 above but One three pin 5 Amp socket outlet point with cables 1.5 sqmm size on independent bord complete all as specified and directed by Engr-in-Charge.
38All as per item No. 36 above but One three pin 5 Amp socket outlet point ,with cables 1.5 sqmm size on same bord complete all as specified and directed by Engr-in-Charge.
39All as per item No. 36 above but One bell point with cables 1.5 sqmm size on independent bord complete all as specified and directed by Engr-in-Charge.
40All as per item No 36 above but FRLSH copper stranded cable of size 2.5 sq mm for 3/6 pin socket outlet 15 amp on one independent board. alongwith all fitting and accessories complete all as specified and directed by Engr-in-Charge.
41M&L for Point wiring complete with 1.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH cable 1100 Volts grade drawn through in and including PVC casing caping of required size with all fittings and accessories alongwith green colour FRLSH Copper conductor cable of size 1.5 sqmm as earth lead for one light point controlled by two way switch and connected to earth dolly PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, regulators or bell push and casing caping terminal box for mounting ceiling rose/ holders etc and making good to disturbed surfaces complete all as specified and directed by Engr-in-Charge.
42M & L for sub main wiring with two single core PVC insulated multi stranded FRLSH Copper conductor cable of size 2x 6.0 sqmm drawn through in and including PVC cashing caping with all accesories and one single core green colour FRLSH Copper conductor cable of size 1 X 6 sqmm as earth wire and connected to earth dolly and making good to disturbed surfaces .NOTE: (a)Two run of cable with one run of earth wire and one run of casing capping will be measured as one unit (RM)
43M & L for surface sub main wiring with four single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2X10.0 sqmm (Nominal area) drawn through in and including PVC cashing caping .suitable size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1X10.0 sqmm as earth lead and connected to earth dolly and making good to disturbed surfaces all as specified and directed. NOTE: (a)Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
44M & L for sub main wiring with two single core PVC insulated multi stranded FRLSH Copper conductor cable of size 2 X 4.0 sqmm drawn through in and including PVC cashing caping with all accesories and one single core green colour FRLSH Copper conductor cable of size 1x 4 sqmm as earth wire and connected to earth dolly and making good to disturbed surfaces complete all as specified and directed by Engr-in-Charge. .NOTE: (a)Two run of cable with one run of earth wire and one run of casing capping will be measured as one unit (RM)
45M & L for surface sub main wiring with four single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2X 2.5.0 sqmm (Nominal area) drawn through in and including PVC cashing caping suitable size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1x 2.5 sqmm as earth lead and connected to earth dolly and making good to disturbed surfaces complete all as specified and directed by Engr-in-Charge. NOTE: (a) Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
46S&F 5 Amp switch Piano flush type single pole one way complete all as specified and directed by Engr-in-Charge.
47S&F 5 Amp switch piano type single pole two way complete all as specified and directed by Engr-in-Charge.
48S & F Angular Lamp holder of PVC/ Polycarbonate type with back plate complete all as specified and directed by Engr-in-Charge.
49S&F socket outlet flush type 6 amps, 5 pin, 230v complete all as specified and directed by Engr-in-Charge.
50S&F switch socket indipendent boad flush type 6 amps, 5 pin, 230v complete all as specified and directed by Engr-in-Charge.
51S&F switch socket combination multipurpose 2-in-1 flush type 3 pin 6 amp and 16 Amp. 230v complete all as specified and directed by Engr-in-Charge.
52S&F ceiling rose surface Bakelite three terminal complete all as specified and directed by Engr-in-Charge.
53S&F ceiling rose surface Bakelite three terminal incl dismentling taking down unsv one complete all as specified and directed by Engr-in-Charge.
54S&F Ding dong calling Bell. Single phase 230 Volt complete all as specified and directed by Engr-in-Charge.
55S&F Sheet metal Enclosure SPN 08 way (MCB DB) Double door, 240 Volts AC complete all as specified and directed by Engr-in-Charge.
56S&F Sheet metal Enclosure SPN 12 way (MCB DB) Double door, 240 Volts AC complete all as specified and directed by Engr-in-Charge.
57S& F for sheet metal enclosure double door DBs triple pole and neutral vertical 415 Volts 8 way (TPN) 16 KA with suitable frame Triple pole 100 Amps in coming MCCBs,bus bars,neutral links,blanking plates IP 43 protection classcomplete all as specified and directed by Engr-in-Charge. ( Note:- Incoming MCCB & out going TP MCB rate Should be inculaded in item.
58S&F for sheet metal enclosure double door DBs triple pole and neutral vertical 415 Volts 6 way (TPN) 16 KA with suitable frame Triple pole 63 Amps in coming MCCBs,bus bars,neutral links,blanking plates IP 43 protection class Note:- Incoming MCCB & out going TP MCB rate Should be inculaded in item.
59S&F for sheet metal enclosure double door DBs triple pole and neutral vertical 415 Volts 4 way (TPN) 16 KA with suitable frame Triple pole 63 Amps in coming MCCBs,bus bars,neutral links,blanking plates IP 43 protection class complete all as specified and directed by Engr-in-Charge. Note:- Incoming MCCB & out going MCB rate Should be inculaded in item.
60S&F MCB, Single Pole, 5 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve complete all as specified and directed by Engr-in-Charge.
61S&F MCB, Single Pole & Neutral , 5 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve complete all as specified and directed by Engr-in-Charge.
62S&F LED Light batten 36 watt, 4 feet AC sleek and seamless profiled extruded polycarbonate batten with an efficient diffuser to illuminate work and retail spaces with three core flexible copper conductor cable from ceiling rose complete all as specified and directed by Engr-in-Charge.
63S&F for LED Recess mounting 2ft X 2ft 1x 36 watt smat slim edge colour temperature, CCT controllable 2x2 LED lighting with remote control with dimming and CCT change option from 2700K to 6500K. housing made from powder coated, CRCA sheet, opaque diffuser for glare free and optimum light with complete accessories.complete all as specified and directed by Engr-in-Charge.
64S&F for LED bay light highly efficient made of die cast aluminium housing with lens embedded PC cover IP 66 and with efficacy of 120lm/W 1x 200 watt complete fitting with accessories. all as specified and directed by Engr-in-Charge. Make. halonix cat part No. HLBLD-ML54-200-CWDL-R-HL2 or equivalent.
65S&F for ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1400 mm sweep. Min air delivery 245 CFM with service value 6.0 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed by Engr-in-Charge. Note - Old UNSV ceiling fan deposit to MES store
66S&F for exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers incl making of suitable hole in brick / stone wall for fixing of Exhust Fan complete all as directed by Engineer-in-charge.Note - Old UNSV Exhaust fan deposit to MES store
67S&F Exhaust fan Metal body light duty 450 mm sweep 230 volt AC complete with frame and Louvers incl making of suitable hole in brick / stone wall for fixing of Exhust Fan complete all as directed by Engineer-in-charge.Note - Old UNSV Exhaust fan deposit to MES store
68Excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth getting out in hard/rock dense soil.
69Excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth getting out in loose/soft dense soil.
70Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated hard/dense soil.
71Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed by Engr-in-charge.
72M & L for sand cushion in trenches for cable protection complete all as directed and specified.
73Supply and lay PCC cable cover class LV type I flat size 250mm x150mmx40mm
74Supply and lay cable XLPE insulated screened PVC beded gavanized steel strip or wire armoured electric power cables(heavy duty) 1100 volts grade with standard aluminum conductor of followng sizes.
75(a)All as per iten No.74 above but 50 Sqmm 3.5 Core.
76(b) All as per iten No.74 above but35 sqmm 3.5 core..
77M&L for high density polyethyne pipes (HDPE) of pressure rating 6 Kgf/cm2 laid in trenches for cable protection under road crossing of size-;
78(a) All as per iten No.77 above but 50mm bore.
79(b) All as per iten No.77 above but 40 mm bore.
80M & L for Earthing complete with galvanised steel earth plate electrode 60X60cm.X 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.complete all as directed by Engineer-in-charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57939774
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 92.02 Lakhs
LAST DATE 10-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Addition/Alteration And Special Repair To Bldg No. P-84 Beg & Centre Khadki Under Ge (Central) Khadki
Basic Detail
Tender No CWE/KKE/TOKEN-84 OF 2024-25
Bidding Type Tender
Location
City Pune
State Maharashtra
Key Dates
Publish Date 23 Oct 2026
Submission Date 10 Nov 2026
Open Date 13 Nov 2026
Finance
Tender Value 92.02 Lakhs
Tender Fee 1000
EMD 1.63 Lakhs
Exemption Not Available
Document List
95056229-aa27-42f2-a51d-0212e22f634f.html
BOQ_889144.xls
Tender84.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 10, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 10 days
Nov 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Nov 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.