Defence Statutory Bodies & Commissions/Committees Closing in 9 days TDR #57939518

Tender For Providing Of Sainik Institute At Hisar Mil Stn

Issued by Statutory Bodies & Commissions/Committees · Hisar, Haryana
Tender Value
5.16 Crore
Estimated cost
Bid Submission
29 Oct 2026
9 days left
EMD
5.83 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Hisar → Haryana
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Providing Of Sainik Institute At Hisar Mil Stn

BOQ

Name of Work:- PROVN OF SAINIK INSTITUTE AT HISAR MIL STN
Sl. No. Item Description
1\\" BOQ \\" BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : CWE HISAR Name of Work: PROVN OF SAINIK INSTITUTE AT HISAR MIL STN Contract No: CWE/HSR-T-30 OF 2026-27 Bidder Name : GENERAL SUMMARY (SCHEDULE OF WORKS) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # NUMBER # Sl.No. Description of Parts/ Item Item Code / Make No. orQty. Unit Pre Priced Rate (in. Rs.) as Defined by MES Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. Ps. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT in Figure TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES
2NOTE:- (Applicable for all parts/items/):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
3Schedule ‘A’ Part-I:Design & built structure work of Sainik Institute with RCC framed structure and permanent specifications incl fitting fixtures all as per drawings/Tender and as directed by Engr-in-Charge.Notes:i). The cost of excavation and earthwork required to achieve the modified ground level, considering the undulations in the natural ground level, shall be measured and paid under Sch ‘A’ Part-XI. The cost of excavation and earthwork required for construction of the building, including foundations, as per the approved design and for achieving the Finished Floor Level (FFL), shall be deemed to be included in the quoted rates of this Schedule and nothing extra shall be paid on this account. ii).The open platform shown in Drawing No. CWE/HSR/WD-09/2026, Sheet No. 2/12, shall be measured and paid for under Sch ‘A’ Part-IX (Open Air Platform).iii). False ceiling shall be provided throughout the building, including the porch, except in the kitchen and corridors. Which comprises of False ceiling Board: 12 mm thick exposed metal frame ceiling with mineral fibre ceiling for fixing in 600 mm x 600 mm gird. False ceiling Grid: - Powder coated groove type GI T grid False ceiling of dimension 15 x 32 mm frame work for false ceiling with Hangers 6 mm dia G.I. (up to 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia. 40 mm long complete all as specified and as directed. iv)Waterproofing treatment and ATT treatment as specified in tender document shall be provided to the building.
4v) AAC block masonry shall be used. Factory-manufactured polymer-modified ready-mix AAC plaster and finish over it shall be as per 27.3 & 27.4 clause of PS.vi). Fittings and fixtures as shown in the drawings shall be deemed to be included in the lump-sum quoted rates, except for the works included in Sch ‘A’ Part-II, III, X and XIII.vii). HPL sheet, Str glazing, Transparent, fibre sheet, Doors, Windows, railing, Grill ventilator for duct, Finishes as defined in tender document are included in quoted rates.viii). Depth of foundation shall be kept min 1.5 mtr from ground level.ix). Finish over external plaster shall comprise two coats of premium elastomeric exterior paint over coats of suitable putty and primer, as per the manufacturer’s instructions. Internal surfaces shall be finished with two coats of premium interior emulsion paint over coats of suitable putty and primer, as per the manufacturer’s instructions.x). Any missing details in the architectural/layout tender drawings, which are inescapable and necessary for structural integrity and proper execution of the work, shall be deemed to be included in the quoted rates, and nothing extra shall be payable to the Contractor on this account.
5Lump sum price worked out by the tenderer for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-II(Ref pre-priced schedule attached separately)
6Lump sum price worked out by the tenderer for INTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-III(Ref pre-priced schedule attached separately)
7Lump sum price worked out by the tenderer for ROAD, PATH AND CULVERT as listed in Schedule ‘A’ Part-IV(Ref pre-priced schedule attached separately)
8Lump sum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-V(Ref pre-priced schedule attached separately)
9Lump sum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI(Ref pre-priced schedule attached separately)
10Lump sum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-VII(Ref pre-priced schedule attached separately)
11Lump sum price worked out by the tenderer for EXTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-VIII(Ref pre-priced schedule attached separately)
12Lump sum price worked out by the tenderer for OPEN AIR PLATFORM as listed in Schedule ‘A’ Part-IX(Ref pre-priced schedule attached separately)
13)Lump sum price worked out by the tenderer for SUMMER APPLIANCES as listed in Schedule ‘A’ Part-X(Ref pre-priced schedule attached separately
14Lump sum price worked out by the tenderer for SITE CLEARANCE, EXCAVATION AND EARTH WORKS as listed in Schedule ‘A’ Part-XI(Ref pre-priced schedule attached separately)
15Lump sum price worked out by the tenderer for COMPOUND WALL/ FENCING AND GATES as listed in Schedule ‘A’ Part-XII(Ref pre-priced schedule attached separately)
16Schedule 'A' Part-XIII(MISCELLANEOUS PARTS)
17Construction of Sentry Post with RCC framed structure and permanent specification all as per drawing and directed by Engr-in-Charge.Note: The cost of excavation, earthwork and all materials as indicated in the drawings and specified in the tender documents shall be deemed to be included in the quoted rates.
18M&L for brick masonry valve pit of size 60x60x60 cm (internal dimension of chamber incl plastering internal and flash pointing external as the work proceeds in same mortar complete with MS sheet cover handle, packing arrangement,earth worth in any type of soil incl removal to n.exc 50 mtr and paint with 2 coats of synthetic enamelled paint over a coat of red oxide primer to steel surfaces complete all as specified
19M&L for brick masonry valve pit of size 105cmx105cmx110 cm (internal dimension of chamber incl plastering internal and flash pointing external as the work proceeds in same mortar complete with MS sheet cover handle, packing arrangement,earth worth in any type of soil incl removal to n.exc 50 mtr and paint with 2 coats of synthetic enamelled paint over a coat of red oxide primer to steel surfaces complete all as specified.
20M&L for provision of fire stand of suitable size made out of MS angle iron/channel including PCC and brickwork for making platform, painting with two coats of synthetic red enamelled paint over a coat of red oxide primer and writing \\"FIRE POINT\\" with white enamelled paint as per standard size of letters and including the following:-(i) Galvanised MS bucket 14 ltr capacity - 04 Nos(ii) Fire extinguisher, dry powder, type 6kg (ABC type) - 08 Nos(iii) Fire baster - 03 Nos(iv) Fire hook - 03 Nos
21S&F heavy duty floor tiles fully vitrified of size 400mm × 400mm, 12mm thick laid over and including 15mm thick screed bed in cement mortar 1:6 joints filled with white cement with admixture of pigment to match with shade of tile complete all as specified and directed by EIC.(For Footpath)
22S&F 15mm bore brass CP health faucet with connection tube/pipe and hook for fixing complete as per Jaquar Cat Part No. ALD-CHR-573 or equivalent as approved by GE.
23S&F 15mm bore dia brass CP sink mixer including connection for mixing hot and cold water screwed down for iron pipe and fixed complete as per Jaquar Cat Part No. COP-CHR-309NPM or equivalent as approved by GE
24S&F 15 mm bore chromium plated fancy type wash hand basin mixer single liver type screwed down for iron pipe and fixed complete as per Jaquar Cat Part No. FLP-5001BPM or equivalent as approved by GE.
25S&F 15 mm bore chromium plated fancy type bib tap, cast copper alloy, screwed down for iron pipe and fixed complete as per Jaquar Cat Part No. COP-CHR-037PM or equivalent as approved by GE.
26S&F 15 mm bore chromium plated fancy type stop valve, cast copper alloy, screwed down for iron pipe and fixed complete as per Jaquar Cat Part No. COP-CHR-053NPM or equivalent as approved by GE.
27&F 15 mm bore chromium plated urinal spreader including connection pipe for fixing complete as per Jaquar Cat Part No. ALD-CHR-1043 or equivalent as approved by GE.
28S&F LED luminaire 600mm x 600mm capacity of 36 watt, 220 Volts, 50HZ recessed type with high efficiency PMMA diffuser soft glare free, anti-flickering light complete with drive holder & LED lamp suitable for roof ceiling complete as per make HPL cat Part No LEDPN36-ECO or equivalent as approved by GE.
29S&F LED COB surface cylinder 15W made of pressure dia cast aluminium housing, powder coated white with professionally designed optics and 10% TDH driver (cut out 130mm) housing is rotatable and tilting with 120 lum/w colour white/warm white complete as per make Crompton Cat Part No. CDR-201-15-57-HL2-NWH or equivalent as approved by GE.
30S&F LED spot down light 15 watt made of pressure dia cast aluminium housing, powder coated white with professionally designed optics and 10% TDH driver (cut out 100mm) with 120 lum/w beam angle and vertical tilting 360 degree colour white/warm white complete as per make Crompton Cat Part No. CDR-212-15-30/40-SL-NWH or equivalent as approved by GE.
31S&F LED strip profile shine 240 LEDs/m LED strip 12 V (with Driver) warm white, high brightness, Energy Efficient single / double side connection complete as per make HPL Cat Part No. FLEXISTRIP5MIP2024V/1ALED830MODV1 or equivalent as approved by GE.
32Supply & installation,testing and commissioning of 11 KV. 630 Amps having short circuit capacity 21kA/3-1 sec, indoor (IP 3X), RMU (Ring Main Unit) 5-way comprising of 02 Nos manually operated Load Break Switches and 03 Nos 630 Amp Fixed-Type spring-charging VCBs, electrolytic grade copper bus bars all inside single, gas-filled, robotically welded stainless steel 304 (Non Ferrite Non Magnetic Grade) tank with minimum thickness 2.5 mm, IP 67 Degree of Protection, internal arc classified 21kA/1sec as per IEC 62271-200. The enclosure shall have pad lockable double-door access with anti-theft hinges, fully covering the front facia and cable boxes to ensure fail-safe anti-theft protection. The unit shall include the following along with all necessary accessories and fittings as required at site.(A) 02 No's Incoming Load Break Switches module each consisting of following accessories.(i) Each switching-unit shall be designed as a three position switch. This three function switch combines the functions of switch-disconnector and earthing switch.(ii) 11kV, 630A Load Break Switch with interlocked line-earthing scheme both short circuit current - 21kA/3-sec, Making Capacity 50kA - 01 No(iii) Auxiliary contacts 1NO+1NC - 01 No (iv) Spring-assisted snap-action manual mechanism with un-inhibited operating shaft for emergency manual operation with integrated earthing switch - 01 No (v) Cable terminals with door arrangement for enhanced safety (IP3X) interlocked to prevent access upto 11 KV, 300 Sqmm, 3 Core, XLPE cable termination in live condition Each Set of 03. (vi) Right angle boots (push on type): Each Set of 03 (vii) Arc proof cable covers having cable entry from bottom, front with Interlocking mechanism including earth switch - 01 No (viii) Capacitive voltage indication fixed type system as per IEC 61243 with LED - 01 Set (ix) Fault Passage Indicator - It shall be provided for each incomer load break unit, FPI with LED/digital display to be added for detection of cable fault - 01 No (x) ON, OFF, EARTH mechanical indication on the front mimic of the panel - 01 No
33(B) 03 Nos. Outgoing VCB module each consisting of following accessories. (i) Each function-unit consists of a vacuum-circuit breaker in combination with a three position-switch. The three-position-switch fulfills the operation of the disconnector-function and earthing function. (ii) 11kV, 630A Fixed-Type VCB module with series disconnector cum earthing switch of short circuit breaking current/withstand - 21kA/3-sec, Making Capacity - 50kAp - 01 No (iii) Aux. contacts 1NO+1NC - 01 No (iv) Stored-energy manual high-endurance spring charging mechanism (M1+), with inbuilt spring-charging lever and mechanically latched ON/OFF push-buttons to allow un-inhibited operation - 01 No (v) Cable terminals with door arrangement for enhanced safety (IP3X) interlocked to prevent access upto 11KV, 185 Sqmm, 3 Core, XLPE cable termination in live-condition - Set of 3 (vi) Right angle boots (push on type) - Set of 3 (vii) Associated ring-core cast-resin insulated CTs 50/1 Amp 2.5 VA, 5P10 for protection - Each Set of 3 (vii) O/C + IE/F self powered numerical protection relay with Low and High set for over current and Earth Fault. Relay shall have the facility to display the maximum loaded phase current also. Relay shall record minimum 5 fault records with time stamping and shall be communicable on MODBUS. (viii) Arc proof cable covers with self Interlocking mechanism with earth switch -01 No (ix) Capacitive voltage indication fixed type system as per IEC 61243 with LED-01 No (x) Mechanically latched buttons for breaker On/Off - 01Set (xi) ON, OFF, TRIP mechanical indication on the front mimic of the panel. (xi) ON, OFF, TRIP mechanical indication on the front mimic of the panel. (C) Additional equipment delivered separately or mounted separately :- (i) Operating Handle for Manual Isolator/Disconnector / Earthing Operation - 01 No (ii) Operation and Maintenance Manual - 01 No, (iii) Installation & Commissioning Manual - 01 No.
34Supplying, installing, testing and commissioning of AC 3 phase 50 HZ 160 KVA capacity transformer step down, out-door type. 11KVA/433 volts copper winding, oil immersed, naturally cooled with external cooling tubes, core type, delta connected on primary (HV) side and star connected on secondary (LV) side in accordance with vector symbol DYN-11 (vector group-4) with neutral brought on secondary (LV) side & having tappings in equal steps of 2.5 % from -7.5% to +7.5% on primary side by means of hand operated off load tap changing gear, so as to change/correct LT voltage on secondary side including provision of all necessary/standard fittings and mainly comprising of :- (a) One cable box on primary HV side having cable glands suitable for 120 sqmm 3 core XLPE 11 KV HT cable (consisting of 3 Nos porcelain HT bushings with brass/ gun metal bushing rods complete with nuts and washers). (b) One cable box on secondary (LV) side consisting of 4 Nos porcelain bushings with GM bushing rods complete with GM nuts, and washers with one No cable gland suitable for reception of outgoing LT PVC sheathed armoured cable of size 300 sqmm 3.5 core. (c) Oil conservator with filter type, drain valve and oil level gauge.(d) Dehydrating breather with first fill of dehydrating agent. (e) Explosive vents. (f) Thermometer pocket on tank cover.(g) One No 100 mm dia dial type thermometer vapour pressure type having range 0-120 degree centigrade with temp reading pointer, max temp indicator resetting device. (h) Rating plate with terminal markings. (i) Two earthing terminals on tank/ tank cover to facilitate fixing of 32 x 6 mm GI earth strip. (j) Oil level gauge. (k) Oil drain and filter valves. (l) Oil filler hole with cap/plug with connections complete. (m) Lifting lugs.
35(n) Air relief valve plug. (o) Four plane solid cast steel detachable rollers. (p) First fill of fresh oil conforming to relevant IS and tested upto 40 KV dielectric strength. (q) Extra bushing for neutral outside the LT cable box for providing independent earthing for neutral. (r) Provision of 2 Nos danger boards 250 x 200 mm size made out of 1.6 mm thick M.S. plate, vitreous enamelled white, with letters. figures of voltage and conventional skull and bones in signal red colour, one at HT side and other on LT side. (s) Any other fittings / accessories so as to conform the whole transformer to IS-1180 (Part-I-2014). Note: - For framed works structural steel sections for mounting platform (including welding, rivating, notching and painting complete) shall be measured and paid seperately.
36Supply and laying double wall corrugated pipe (DWC) conforming to IS 19430 Part - I of size 50mm outer dia and 38 mm inner dia complete all as specified and as directed
37Supply and fixing cable route indicator made cast iron 150mm clear hight with 100 mm long embedded in PCC 1:3:6 type C-1 ( using 20mm stone aggregate ) with Letter \\"LT CABLE/HT CABLE\\" suitable inscribed on one CI circular plate welded with angle iron including necessary earth work and two coat of synthetic enamel paint over a coat of red oxide primer on steel surface complete all as specified and directed
38Supply , fixing, installing and commissioning of octagonal Hot-Dip Galvanised street light pole 7 mtr long ,Top dia 70mm Bottom dia 130 mm, sheet thickness 3mm and base plate dimensions 200x200x12mm, foundation bolts M19x600 and 1.5 mtr Single arms bracket, 1100 volts grade, including cost of nuts and bolts and all accessories as supplied by the manufature including cost foundation accessories etc, the foundation bolts as per manufactureer design should be hot dipped galvanised pole complete with door locking arrangement, Terminal plate consisting of 2 nos10A, 4 pole natural links including connection etc with suitable connecting arrangement for 2 nos, cost of RCC 1:1.5:3 for foundation of size 0.7m x0.7mx1.8m with minimum 8 nos 12 mm dia longitudinal MS reinforcement rods with rings of 8 mm dia not more than 200mm cement concrete for fixing the pole with labour and material required to complete all as specified and directed .
39S&F 15 W LED bollard light with opal acrylic diffuser , high surge protection, integrated LED driver , high durablity with IP-66 complete as per make Crompton Cat Part No. LBLSN-10CDL or equivalent as approved by GE.
40Supply, installation, commissioning and testing of LT Panel ,LT(415 Volts, 50 Hz , 3-phase, 4 wire supply) CPRI approved, factory assembled ,out door type, weather and vermin proof (Protection Class IP-54) made out of 50mm x 50mm x 5mm angle iron frame and 3.15 mm(for external) and 3.15 mm (for internal) thick MS Sheet CRCA sheet with both side (front and back) hinged , double door opening for external, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enamel gray paint First Quality) over a coat of red oxide primer complete mounted on angle iron 50mm x 50mm x 5 mm legs 45 cm high above GL and 15 cm embedded in ground with and including bocks of PCC 1:2:4 type C1 of block size 30x30x30 cm comprising of the following.(a) Bus bar chamber having 4 nos air insulated Aluminium strip bus bars of rating not less than the 1.5 times the rated capacity of the incomer MCCB, bus bar must be colour coded heat shrinkable as well as outgoings shall have aluminium four pole (bus bar) of current carrying capacity not less than 1.5 times the rated capacity of individual MCCBs.(b) Incoming :-(i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade, 300 amps rating 4 pole, 50 KA, Adjustable thermal and magnetic release specially fixed for incoming supply with overload ,short circuit and earth fault protection ,adjustable type (Ics=100%Icu).-01 No. (ii) Voltmeter 0-500V with selector switch 96 mm X 96 mm square flush mounted , with three way rotary selector switch-1 No.(iii) Ammeter size 96 mm X 96 mm square dial flush pattern having dual range 500 amp with three way rotary selector switch- 01 no.(iv) Three Nos CTs of suitable ratio (set of three)-01 Set(v) Indicating lamps (R,Y,B) - 01 set of three
41(c) Outgoing(i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade 160 amps rating and 16 KA rupturing capacity, adjustable thermal and fixed magnetic type specially fixed for incoming supply with overload ,short circuit and earth fault protection ,adjustable type (Ics=100%Icu) - 02 No(ii) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade 25 amps rating and 10 KA rupturing capacity, adjustable thermal and fixed magnetic type( Ics=100%Icu). -01 No.(iii) MCB TPN , 415 Volts, 50 Hz AC of capacity 40-63 Amps rating - 1 Nos”(d) Fine wiring with single core copper conductor for instruments / indicating lamps-01 Job.(e) Nature Switch control panelNote:-(i) All incoming/ outgoing cables shall be connected by suitable size gland plate /glands. And All spreader terminals of MCCBs should be connected with extension links (bus bar). Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57939518
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 5.16 Crore
LAST DATE 29-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Providing Of Sainik Institute At Hisar Mil Stn
Basic Detail
Tender No CWE/HSR/T-30 OF 2026-27
Bidding Type Tender
Location
City Hisar
State Haryana
Key Dates
Publish Date 08 Oct 2026
Submission Date 29 Oct 2026
Open Date 31 Oct 2026
Finance
Tender Value 5.16 Crore
Tender Fee 3000
EMD 5.83 Lakhs
Exemption Not Available
Document List
sainikdrwg.pdf
Tendernotice_1.pdf
81606TD.pdf
BOQ_888948.xls
ce5bfb6f-7d0c-4d94-b967-3d5c7dbfe534.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 08, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Oct 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
pdf

sainikdrwg.pdf

pdf

Tendernotice_1.pdf

pdf

81606TD.pdf

xls

BOQ_888948.xls

html

ce5bfb6f-7d0c-4d94-b967-3d5c7dbfe534.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender