Defence Government Departments Closing in 12 days TDR #57938443

Bids Are invited for Arm Chp 2026 27 16Th Bn

Issued by Government Departments · Leh, Ladakh
Tender Value
5.39 Lakhs
Estimated cost
Bid Submission
30 Oct 2026
12 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Leh → Ladakh
EMD Exemption
Available
Quantity
647

Project Description

Bids Are invited for Arm Chp 2026 27 16Th Bn Providing And Replacement Of Glycol Motor Seal And Bearing Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Motor Seal , Servicing And Rewinding Of 7.50 Hp Monoblock Motor Including Providing , Providing And Replacement Of Fan Coil Unit Connection Pipe Nipple Size 1Inch As Per Direction Of Engineer Incharge , Rewinding Of Fan Coil Unit Motor With Neccessory Repair Whichever Will Required During The Servicing, Labour Charges And Proper Testing Of Functioning Of Motor , Providing And Servicing Of F.Cu Air Filter As Per Direction Of Engineer Incharge , Servicing Of Burner Including Required Deep Cleaning Up To Satisfactory Mark As Per Direction Of Engineer Incharge , Providing And Replacement Of Burner Nozzle As Per Direction Of Engineer Incharge, , Providing And Replacement Of Burner On Off Switch As Per Direction Of Engineer Incharge, , Supplying Of Filling Of Glycol As Per Direction Of Engineer Incharge , Providing And Replacement Pressure Gauge As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Pressure Gauge , Providing And Replacement Photo Cell As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Burnt Photo Cell , Providing And Replacement Brass Gate Valve 25Mm As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Brass Gate Valve 25Mm , Providing And Replacement Sequence Controller As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Sequence Controller , Providing And Replacement Burner Ignition Transformer As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Burner Ignition Transformer , Providing And Replacement Burner Fuel Pump As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Burner Fuel Pump , Servicing And Repair Of Motor Starter As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Materials , Providing And Replacement Of F.C.U With Radiator Panel As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Heating Blower Unit , Rejointing The Chp Heat Liquid Carrying Pipe By Repairing Pipe Jointing With Appropriate Material Etc As Per Direction Of Engineer Incharge. , Servicing And Rewinding Of 0.5 Hp Monoblock Motor Pump Including Providing And Fixing Copper Wire , Providign Insulation Of Nitrile Rubber Insulation Tube Of Wall Thickness 06-10 Mm For 80-110 Mm Dia Pipes , Providign Insulation Of Nitrile Rubber Insulation Tube Of Wall Thickness 06-10 Mm For 15-25 Mm Dia Pipes - Providing And Replacement Of Glycol Motor Seal And Bearing Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Motor Seal - Providing And Replacement Of Glycol Motor Seal And Bearing Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Motor Seal ( Note- Old Scrap Material Held With Vender After Replacement ). , Servicing And Rewinding Of 7.50 Hp Monoblock Motor Including Providing - Servicing And Rewinding Of 7.50 Hp Monoblock Motor Including Providing And Fixing Of 7 Kg, Copper Wire, Warnish 01 Ltr, Slive Mix 20 Pcs, Paper P Class 01 Set, Paper P Sheet 01 Set, Solding Wire 01 Set, Brearing 02 Nos, Cotton Tape 01 Nos, Dr Tape 01 Nos, Thimbles 01 Set, With Neccessory Repair Whichever Will Required During The Servicing/ Labour Charges And Proper Testing Of Functioning Of Motor After Servicing On Load As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Burnt Copper Wire ( Note- Old Scrap Material Held With Vender After Replacement ). , Providing And Replacement Of Fan Coil Unit Connection Pipe Nipple Size 1Inch As Per Direction Of Engineer Incharge - Providing And Replacement Of Fan Coil Unit Connection Pipe Nipple (Size 1Inch) As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Coil Unit Connection Pipe Nipple (Size 1Inch) ( Note- Old Scrap Material Held With Vender After Replacement ). , Rewinding Of Fan Coil Unit Motor With Neccessory Repair Whichever Will Required During The Servicing, Labour Charges And Proper Testing Of Functioning Of Motor - Rewinding Of Fan Coil Unit Motor With Neccessory Repair Whichever Will Required During The Servicing/ Labour Charges And Proper Testing Of Functioning Of Motor After Servicing On Load As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Burnt Copper Wire ( Note- Old Scrap Material Held With Vender After Replacement ). , Providing And Servicing Of F.Cu Air Filter As Per Direction Of Engineer Incharge , Servicing Of Burner Including Required Deep Cleaning Up To Satisfactory Mark As Per Direction Of Engineer Incharge , Providing And Replacement Of Burner Nozzle As Per Direction Of Engineer Incharge, - Providing And Replacement Of Burner Nozzle As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Burner Nozzle ( Note- Old Scrap Material Held With Vender After Replacement ). , Providing And Replacement Of Burner On Off Switch As Per Direction Of Engineer Incharge, - Providing And Replacement Of Burner On/Off Switch As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Burner On/Off Switch ( Note- Old Scrap Material Held With Vender After Replacement ). , Supplying Of Filling Of Glycol As Per Direction Of Engineer Incharge , Providing And Replacement Pressure Gauge As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Pressure Gauge - Providing And Replacement Pressure Gauge As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Pressure Gauge ( Note- Old Scrap Material Held With Vender After Replacement ). , Providing And Replacement Photo Cell As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Burnt Photo Cell - Providing And Replacement Photo Cell As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Burnt Photo Cell ( Note- Old Scrap Material Held With Vender After Replacement ). , Providing And Replacement Brass Gate Valve 25Mm As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Brass Gate Valve 25Mm - Providing And Replacement Brass Gate Valve 25Mm As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Brass Gate Valve 25Mm ( Note- Old Scrap Material Held With Vender After Replacement ). , Providing And Replacement Sequence Controller As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Sequence Controller - Providing And Replacement Sequence Controller As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Sequence Controller ( Note- Old Scrap Material Held With Vender After Replacement ). , Providing And Replacement Burner Ignition Transformer As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Burner Ignition Transformer - Providing And Replacement Burner Ignition Transformer As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Burner Ignition Transformer ( Note- Old Scrap Material Held With Vender After Replacement ). , Providing And Replacement Burner Fuel Pump As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Burner Fuel Pump - Providing And Replacement Burner Fuel Pump As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Burner Fuel Pump ( Note- Old Scrap Material Held With Vender After Replacement ). , Servicing And Repair Of Motor Starter As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Materials - Servicing And Repair Of Motor Starter As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Materials ( Note- Old Scrap Material Held With Vender After Replacement ). , Providing And Replacement Of F.C.U With Radiator Panel As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Heating Blower Unit - Providing And Replacement Of F.C.U With Radiator Panel As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Heating Blower Unit ( Note- Old Scrap Material Held With Vender After Replacement ). , Rejointing The Chp Heat Liquid Carrying Pipe By Repairing Pipe Jointing With Appropriate Material Etc As Per Direction Of Engineer Incharge. - Rejointing The Chp Heat Liquid Carrying Pipe By Repairing Pipe/Jointing With Appropriate Material Etc As Per Direction Of Engineer Incharge. , Servicing And Rewinding Of 0.5 Hp Monoblock Motor Pump Including Providing And Fixing Copper Wire - Servicing And Rewinding Of 0.5 Hp Monoblock Motor Pump Including Providing And Fixing Copper Wire, And Bearing Set With Neccessory Repair Whichever Will Required During The Servicing/ Labour Charges And Proper Testing Of Functioning Of Motor After Servicing On Load As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Burnt Copper Wire ( Note- Old Scrap Material Held With Vender After Replacement ). , Providign Insulation Of Nitrile Rubber Insulation Tube Of Wall Thickness 06-10 Mm For 80-110 Mm Dia Pipes - Providign Insulation Of Nitrile Rubber Insulation Tube Of Wall Thickness 06-10 Mm For 80-110 Mm Dia Pipes Including Removing Damaged Insulation And Applying New Nytril Insulation And With Jointing Ss Sheet Scering As Per Direction Of Engineer In Charge. , Providign Insulation Of Nitrile Rubber Insulation Tube Of Wall Thickness 06-10 Mm For 15-25 Mm Dia Pipes - Providign Insulation Of Nitrile Rubber Insulation Tube Of Wall Thickness 06-10 Mm For 15-25 Mm Dia Pipes Including Removing Damaged Insulation And Applying New Nytril Insulation And With Jointing Ss Sheet Scering As Per Direction Of Engineer In Charge.

BOQ

Sl. No. Item TitleItem Description
1Providing and Replacement of glycol motor seal and bearing per direction of engineer incharge, including deduction of cost of old unserviceable motor sealProviding and Replacement of glycol motor seal and bearing per direction of engineer incharge, including deduction of cost of old unserviceable motor seal ( Note- Old scrap material held with vender after replacement ).
2Servicing and rewinding of 7.50 HP monoblock motor including ProvidingServicing and rewinding of 7.50 HP monoblock motor including Providing and Fixing of 7 Kg, copper wire, warnish 01 ltr, slive mix 20 pcs, paper P class 01 set, paper P sheet 01 set, solding wire 01 set, brearing 02 nos, cotton tape 01 nos, dr tape 01 nos, thimbles 01 set, with neccessory repair whichever will required during the servicing/ labour charges and proper testing of functioning of motor after servicing on load as per direction of engineer incharge, including deduction of cost of old burnt copper wire ( Note- Old scrap material held with vender after replacement ).
3Providing and Replacement of fan coil unit Connection pipe nipple Size 1inch as per direction of engineer inchargeProviding and Replacement of fan coil unit Connection pipe nipple (Size 1inch) as per direction of engineer incharge, including deduction of cost of old unserviceable coil unit Connection pipe nipple (Size 1inch) ( Note- Old scrap material held with vender after replacement ).
4Rewinding of fan coil unit motor with neccessory repair whichever will required during the servicing, labour charges and proper testing of functioning of motorRewinding of fan coil unit motor with neccessory repair whichever will required during the servicing/ labour charges and proper testing of functioning of motor after servicing on load as per direction of engineer incharge, including deduction of cost of old burnt copper wire ( Note- Old scrap material held with vender after replacement ).
5Providing and Servicing of F.CU Air filter as per direction of engineer inchargeProviding and Servicing of F.CU Air filter as per direction of engineer incharge
6Servicing of Burner including required deep cleaning up to satisfactory mark as per direction of engineer inchargeServicing of Burner including required deep cleaning up to satisfactory mark as per direction of engineer incharge
7Providing and Replacement of Burner Nozzle as per direction of engineer incharge,Providing and Replacement of Burner Nozzle as per direction of engineer incharge, including deduction of cost of old unserviceable Burner Nozzle ( Note- Old scrap material held with vender after replacement ).
8Providing and Replacement of Burner on off switch as per direction of engineer incharge,Providing and Replacement of Burner on/off switch as per direction of engineer incharge, including deduction of cost of old unserviceable Burner on/off switch ( Note- Old scrap material held with vender after replacement ).
9Supplying of filling of glycol as per direction of engineer inchargeSupplying of filling of glycol as per direction of engineer incharge
10Providing and Replacement pressure gauge as per direction of engineer incharge, including deduction of cost of old unserviceable pressure gaugeProviding and Replacement pressure gauge as per direction of engineer incharge, including deduction of cost of old unserviceable pressure gauge ( Note- Old scrap material held with vender after replacement ).
11Providing and Replacement photo cell as per direction of engineer incharge, including deduction of cost of old burnt photo cellProviding and Replacement photo cell as per direction of engineer incharge, including deduction of cost of old burnt photo cell ( Note- Old scrap material held with vender after replacement ).
12Providing and Replacement brass gate valve 25mm as per direction of engineer incharge, including deduction of cost of old unserviceable brass gate valve 25mmProviding and Replacement brass gate valve 25mm as per direction of engineer incharge, including deduction of cost of old unserviceable brass gate valve 25mm ( Note- Old scrap material held with vender after replacement ).
13Providing and Replacement sequence controller as per direction of engineer incharge, including deduction of cost of old unserviceable sequence controllerProviding and Replacement sequence controller as per direction of engineer incharge, including deduction of cost of old unserviceable sequence controller ( Note- Old scrap material held with vender after replacement ).
14Providing and Replacement burner ignition transformer as per direction of engineer incharge, including deduction of cost of old unserviceable burner ignition transformerProviding and Replacement burner ignition transformer as per direction of engineer incharge, including deduction of cost of old unserviceable burner ignition transformer ( Note- Old scrap material held with vender after replacement ).
15Providing and Replacement burner fuel pump as per direction of engineer incharge, including deduction of cost of old unserviceable burner fuel pumpProviding and Replacement burner fuel pump as per direction of engineer incharge, including deduction of cost of old unserviceable burner fuel pump ( Note- Old scrap material held with vender after replacement ).
16Servicing and Repair of motor starter as per direction of engineer incharge, including deduction of cost of old unserviceable materialsServicing and Repair of motor starter as per direction of engineer incharge, including deduction of cost of old unserviceable materials ( Note- Old scrap material held with vender after replacement ).
17Providing and Replacement of F.C.U with Radiator panel as per direction of engineer incharge, including deduction of cost of old unserviceable heating blower unitProviding and Replacement of F.C.U with Radiator panel as per direction of engineer incharge, including deduction of cost of old unserviceable heating blower unit ( Note- Old scrap material held with vender after replacement ).
18Rejointing the CHP heat liquid carrying pipe by repairing pipe jointing with appropriate material etc as per direction of engineer incharge.Rejointing the CHP heat liquid carrying pipe by repairing pipe/jointing with appropriate material etc as per direction of engineer incharge.
19Servicing and rewinding of 0.5 HP monoblock motor pump including Providing and Fixing copper wireServicing and rewinding of 0.5 HP monoblock motor pump including Providing and Fixing copper wire, and bearing set with neccessory repair whichever will required during the servicing/ labour charges and proper testing of functioning of motor after servicing on load as per direction of engineer incharge, including deduction of cost of old burnt copper wire ( Note- Old scrap material held with vender after replacement ).
20Providign insulation of nitrile rubber insulation tube of wall thickness 06-10 mm for 80-110 mm dia pipesProvidign insulation of nitrile rubber insulation tube of wall thickness 06-10 mm for 80-110 mm dia pipes including removing damaged insulation and applying new nytril insulation and with jointing SS sheet scering as per direction of Engineer in charge.
21Providign insulation of nitrile rubber insulation tube of wall thickness 06-10 mm for 15-25 mm dia pipesProvidign insulation of nitrile rubber insulation tube of wall thickness 06-10 mm for 15-25 mm dia pipes including removing damaged insulation and applying new nytril insulation and with jointing SS sheet scering as per direction of Engineer in charge.

AI Tender Summary

OUR REF NO 57938443
AUTHORITY Government Departments
TENDER VALUE 5.39 Lakhs
LAST DATE 30-10-2026
Authority
Authority Name Indo Tibetan Border Police
Work Description Bids Are invited for Arm Chp 2026 27 16Th Bn Providing And Replacement Of Glycol Motor Seal And Bearing Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Motor Seal , Servicing And Rewinding Of 7.50 Hp Monoblock Motor Including Providing , Providing And Replacement Of Fan Coil Unit Connection Pipe Nipple Size 1Inch As Per Direction Of Engineer Incharge , Rewinding Of Fan Coil Unit Motor With Neccessory Repair Whichever Will Required During The Servicing, Labour Charges And Proper Testing Of Functioning Of Motor , Providing And Servicing Of F.Cu Air Filter As Per Direction Of Engineer Incharge , Servicing Of Burner Including Required Deep Cleaning Up To Satisfactory Mark As Per Direction Of Engineer Incharge , Providing And Replacement Of Burner Nozzle As Per Direction Of Engineer Incharge, , Providing And Replacement Of Burner On Off Switch As Per Direction Of Engineer Incharge, , Supplying Of Filling Of Glycol As Per Direction Of Engineer Incharge , Providing And Replacement Pressure Gauge As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Pressure Gauge , Providing And Replacement Photo Cell As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Burnt Photo Cell , Providing And Replacement Brass Gate Valve 25Mm As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Brass Gate Valve 25Mm , Providing And Replacement Sequence Controller As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Sequence Controller , Providing And Replacement Burner Ignition Transformer As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Burner Ignition Transformer , Providing And Replacement Burner Fuel Pump As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Burner Fuel Pump , Servicing And Repair Of Motor Starter As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Materials , Providing And Replacement Of F.C.U With Radiator Panel As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Heating Blower Unit , Rejointing The Chp Heat Liquid Carrying Pipe By Repairing Pipe Jointing With Appropriate Material Etc As Per Direction Of Engineer Incharge. , Servicing And Rewinding Of 0.5 Hp Monoblock Motor Pump Including Providing And Fixing Copper Wire , Providign Insulation Of Nitrile Rubber Insulation Tube Of Wall Thickness 06-10 Mm For 80-110 Mm Dia Pipes , Providign Insulation Of Nitrile Rubber Insulation Tube Of Wall Thickness 06-10 Mm For 15-25 Mm Dia Pipes - Providing And Replacement Of Glycol Motor Seal And Bearing Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Motor Seal - Providing And Replacement Of Glycol Motor Seal And Bearing Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Motor Seal ( Note- Old Scrap Material Held With Vender After Replacement ). , Servicing And Rewinding Of 7.50 Hp Monoblock Motor Including Providing - Servicing And Rewinding Of 7.50 Hp Monoblock Motor Including Providing And Fixing Of 7 Kg, Copper Wire, Warnish 01 Ltr, Slive Mix 20 Pcs, Paper P Class 01 Set, Paper P Sheet 01 Set, Solding Wire 01 Set, Brearing 02 Nos, Cotton Tape 01 Nos, Dr Tape 01 Nos, Thimbles 01 Set, With Neccessory Repair Whichever Will Required During The Servicing/ Labour Charges And Proper Testing Of Functioning Of Motor After Servicing On Load As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Burnt Copper Wire ( Note- Old Scrap Material Held With Vender After Replacement ). , Providing And Replacement Of Fan Coil Unit Connection Pipe Nipple Size 1Inch As Per Direction Of Engineer Incharge - Providing And Replacement Of Fan Coil Unit Connection Pipe Nipple (Size 1Inch) As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Coil Unit Connection Pipe Nipple (Size 1Inch) ( Note- Old Scrap Material Held With Vender After Replacement ). , Rewinding Of Fan Coil Unit Motor With Neccessory Repair Whichever Will Required During The Servicing, Labour Charges And Proper Testing Of Functioning Of Motor - Rewinding Of Fan Coil Unit Motor With Neccessory Repair Whichever Will Required During The Servicing/ Labour Charges And Proper Testing Of Functioning Of Motor After Servicing On Load As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Burnt Copper Wire ( Note- Old Scrap Material Held With Vender After Replacement ). , Providing And Servicing Of F.Cu Air Filter As Per Direction Of Engineer Incharge , Servicing Of Burner Including Required Deep Cleaning Up To Satisfactory Mark As Per Direction Of Engineer Incharge , Providing And Replacement Of Burner Nozzle As Per Direction Of Engineer Incharge, - Providing And Replacement Of Burner Nozzle As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Burner Nozzle ( Note- Old Scrap Material Held With Vender After Replacement ). , Providing And Replacement Of Burner On Off Switch As Per Direction Of Engineer Incharge, - Providing And Replacement Of Burner On/Off Switch As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Burner On/Off Switch ( Note- Old Scrap Material Held With Vender After Replacement ). , Supplying Of Filling Of Glycol As Per Direction Of Engineer Incharge , Providing And Replacement Pressure Gauge As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Pressure Gauge - Providing And Replacement Pressure Gauge As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Pressure Gauge ( Note- Old Scrap Material Held With Vender After Replacement ). , Providing And Replacement Photo Cell As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Burnt Photo Cell - Providing And Replacement Photo Cell As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Burnt Photo Cell ( Note- Old Scrap Material Held With Vender After Replacement ). , Providing And Replacement Brass Gate Valve 25Mm As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Brass Gate Valve 25Mm - Providing And Replacement Brass Gate Valve 25Mm As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Brass Gate Valve 25Mm ( Note- Old Scrap Material Held With Vender After Replacement ). , Providing And Replacement Sequence Controller As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Sequence Controller - Providing And Replacement Sequence Controller As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Sequence Controller ( Note- Old Scrap Material Held With Vender After Replacement ). , Providing And Replacement Burner Ignition Transformer As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Burner Ignition Transformer - Providing And Replacement Burner Ignition Transformer As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Burner Ignition Transformer ( Note- Old Scrap Material Held With Vender After Replacement ). , Providing And Replacement Burner Fuel Pump As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Burner Fuel Pump - Providing And Replacement Burner Fuel Pump As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Burner Fuel Pump ( Note- Old Scrap Material Held With Vender After Replacement ). , Servicing And Repair Of Motor Starter As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Materials - Servicing And Repair Of Motor Starter As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Materials ( Note- Old Scrap Material Held With Vender After Replacement ). , Providing And Replacement Of F.C.U With Radiator Panel As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Heating Blower Unit - Providing And Replacement Of F.C.U With Radiator Panel As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Unserviceable Heating Blower Unit ( Note- Old Scrap Material Held With Vender After Replacement ). , Rejointing The Chp Heat Liquid Carrying Pipe By Repairing Pipe Jointing With Appropriate Material Etc As Per Direction Of Engineer Incharge. - Rejointing The Chp Heat Liquid Carrying Pipe By Repairing Pipe/Jointing With Appropriate Material Etc As Per Direction Of Engineer Incharge. , Servicing And Rewinding Of 0.5 Hp Monoblock Motor Pump Including Providing And Fixing Copper Wire - Servicing And Rewinding Of 0.5 Hp Monoblock Motor Pump Including Providing And Fixing Copper Wire, And Bearing Set With Neccessory Repair Whichever Will Required During The Servicing/ Labour Charges And Proper Testing Of Functioning Of Motor After Servicing On Load As Per Direction Of Engineer Incharge, Including Deduction Of Cost Of Old Burnt Copper Wire ( Note- Old Scrap Material Held With Vender After Replacement ). , Providign Insulation Of Nitrile Rubber Insulation Tube Of Wall Thickness 06-10 Mm For 80-110 Mm Dia Pipes - Providign Insulation Of Nitrile Rubber Insulation Tube Of Wall Thickness 06-10 Mm For 80-110 Mm Dia Pipes Including Removing Damaged Insulation And Applying New Nytril Insulation And With Jointing Ss Sheet Scering As Per Direction Of Engineer In Charge. , Providign Insulation Of Nitrile Rubber Insulation Tube Of Wall Thickness 06-10 Mm For 15-25 Mm Dia Pipes - Providign Insulation Of Nitrile Rubber Insulation Tube Of Wall Thickness 06-10 Mm For 15-25 Mm Dia Pipes Including Removing Damaged Insulation And Applying New Nytril Insulation And With Jointing Ss Sheet Scering As Per Direction Of Engineer In Charge.
Basic Detail
Tender No GEM/2026/B/8137049
Bidding Type Tender
Location
City Leh
State Ladakh
Key Dates
Publish Date 08 Oct 2026
Submission Date 30 Oct 2026
Open Date 31 Oct 2026
Finance
Tender Value 5.39 Lakhs
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Available
Document List
ea269de4-3b8c-4f59-aa8b-57fcd1d312e8.pdf
1791480477.xlsx
chp16thbn26-27_undertaking_2026-10-08-22-44-51_077915daf05975f543cab5e388378dcf.pdf
10007918_Boq_1.xlsx
CHP16thbn_f87ef06f-cef3-45a7-b9b91791482423722_acengr16thbn.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 08, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Oct 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
pdf

ea269de4-3b8c-4f59-aa8b-57fcd1d312e8.pdf

xlsx

1791480477.xlsx

pdf

chp16thbn26-27_undertaking_2026-10-08-22-44-51_077915daf05975f543cab5e388378dcf.pdf

xlsx

10007918_Boq_1.xlsx

pdf

CHP16thbn_f87ef06f-cef3-45a7-b9b91791482423722_acengr16thbn.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender