Tender for Renovation And Modification Of Existing Industrial Estate Building , Leh For Establishment Of Seabuckthorn Incubation Centre Leh Ladakh,
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling wooden boardings in lining of walls and partitions, excludingsupporting members but including stacking within 50 metres lead : Thickness above 10 mm up to 25 mm |
| 2 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stoneaggregate) finished 40 mm thick with 20 mm nominal size stone aggregate |
| 3 | Providing and laying Vitrified tiles in different sizes (thickness to be specified bythe manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, in skirting,riser of steps, laid with cement based high polymer modified quick set tileadhesive (water based) conforming to IS: 15477, in average 6 mm thickness,including grouting of joints (Payment for grouting of joints to be madeseparately).Size of Tile 600x600 mm |
| 4 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cementmortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per sqm, including pointing in white cement mixed with pigment ofmatching shade complete. |
| 5 | Dismantling tile work in floors and roofs laid in cement mortar including stackingmaterial within 50 metres lead.For thickness of tiles above 25 mm and up to 40 mm |
| 6 | Providing and fixing aluminium work for doors, windows, ventilators andpartitions with extruded built up standard tubular sections/ appropriate Zsections and other sections of approved make conforming to IS: 733 and IS : 1285,fixed with rawl plugs and screws or with fixing clips, or with expansion holdfasteners including necessary filling up of gaps at junctions, at top, bottom andsides with required PVC/neoprene felt etc. Aluminium sections shall be smooth,rust free, straight, mitred and jointed mechanically wherever required includingcleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainlesssteel screws, all complete as per architectural drawings and the directions ofEngineer-in-charge. (Glazing and panelling to be paid for separately): For fixed portion.Anodised aluminium (anodised transparent or dyed to required shade accordingto IS: 1868, Minimum anodic coating of grade AC 15) |
| 7 | For shutters of doors, windows & ventilators including providing and fixinghinges/ pivots and making provision for fixing of fittings wherever requiredincluding the cost of EPDM rubber / neoprene gasket required (Fittings shall bepaid for separately)Anodised aluminium (anodised transparent or dyed to required shade accordingto IS: 1868, Minimum anodic coating of grade AC 15) |
| 8 | Providing and fixing glazing in aluminium door, window, ventilator shutters andpartitions etc. with EPDM rubber / neoprene gasket etc. complete as per thearchitectural drawings and the directions of engineer-in-charge . (Cost ofaluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) |
| 9 | Fencing with angle iron post placed at required distance embedded incementCstrutted on both sides and end post on one side only and provided withhorizontal 9.38 kg per 100 m (minimum), between the two posts fitted and fixedwith G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth workand concrete work to be paid for separately). Payment to be made per metrecost of total length of barbed wire used.With G.I. barbed wire |
| 10 | Supplying at site Angle iron post & strut of required size including bottom to besplit and bent at right angle in opposite direction for 10 cm length and drillingholes upto 10 mm dia. etc. complete |
| 11 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size25x25 mm made of G.I.wire of dia 3 mm including strengthening with 2 mm diawire or nuts, bolts and washers as required complete as per the direction ofEngineer-in-charge. |
| 12 | Making the opening in brick masonry including dismantling in floor or walls bycutting masonry and making good the damages to walls, flooring and jambscomplete, to match existing surface i/c disposal of mulba/ rubbish to the nearestmunicipal dumping ground, all complete as per direction of Engineer-in-Charge. For door/ window/ clerestory window |
| 13 | Dismantling doors, windows and clerestory windows (steel or wood) shutterincluding chowkhats, architrave, holdfasts etc. complete and stacking within 50metres lead :Of area 3 sq. metres and below |
| 14 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 gradedstone aggregate 20 mm nominal size derived from natural sources) |
| 15 | Random rubble masonry with hard stone in foundation and plinth includinglevelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 gradedstone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 16 | Retaining walls, return walls, walls (any thickness) including attached pilasters,buttresses, plinth and string courses fillets, kerbs and steps etc. |
| 17 | Supplying and fixing rolling shutters of approved make, made of required sizeM.S. laths, interlocked 80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 18 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Twoor more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.80 ltr/10 sqm of approved brand and manufacture |
| 19 | Providing and fixing of strip curtains all work complete job, as instructed by site engineer incharge |
| 20 | Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required. Group A |
| 21 | Supplying and fixing of following electrical items suitable for operating on 240 / 230 volts AC, 50 HZ Supply, including connection etc, as required . Exhaust fan 250mm size ( Heavy duty ) CG transair or equivalent approved make |
| 22 | Supply installation, testing & commissioning of GI Electrode Earthing with 84mm dia and 3 meter length, with 3mm thick the electrode should be hot dip galvinised . The GI Electrode shall be pre filled with cristaline conductive material ( CCM) maximum contact between the electrode and compound should be eco- friendly GI Electrode Earthing should be eco- friendly GI Electrode Earthing should be eco-friendly GI Electorde Earthing should be maintinance free and does not require regular manual addition of water. The earthing pit should be covered with PVC cover. |
| 23 | Supplying and laying 25mm x5mm GI strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I nut, bolt, spring , washer etc as required ( jointing shall be done by overlapping and with 2 sets of G.I nut bolt & spring washer spaced at |
| 24 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or inrecess for connections etc. as required. |
| 25 | Fabrication, supplying , installation testing and commissioning of following pannel made out of 2mm thick M.S sheet, floor mounted, vermin and dust proof ,indoor duly painted with provsion for fixing of 1 nos incomer MCCB, MCCB type change over switch-1 nos including supply and fixing 2 set of Aluminium bus bar and strip for housing MCB,s 24 Nos, MF Digital Meter and other allied accessories as required ( make as per annexure ) |
| 26 | Providing and fixing 37 mm thick factory made PVC door shutter, styles and railsmade of PVC hollowsection of size 100 mm x 37 mm with wall thickness 2 mm (±0.2 mm), with inbuilt bead on one side,styles and rails mitered cut and joint atthe corners by means of 2 nos of plastic brackets of size 75 mm x221 mm at each corner and stainless steel screws, reinforcing the hinge side of style by inserting PVCprofile of size 28 mm x 30 mm, with wall thickness 2 mm ( ± 0.2 mm). Lockrail of size 100 mm x 37 mm,wall thickness 2 mm (+ 0.2 mm) will be fixed to the vertical styles. Providing with PVC snapfit beads andpanel of size 100 mm x 20 mm, and inserting 2 nos tie bar of 6 mm dia and fastening with nuts andwashers complete, all as per manufacturer's specification and direction of Engineer-incharge. |
| 27 | Dismantling tile work in floors and roofs laid in cement mortar including stackingmaterial within 50 metres lead. For thickness of tiles 10 mm to 25 mm |
| 28 | Providing and applying plaster of paris putty of 2 mm thickness over plasteredsurface to prepare the surface even and smooth complete. |
| 29 | Painting with synthetic enamel paint of approved brand and manufacture ofrequired colour to give an even shade :Two or more coats on new work over an under coat of suitable shade withordinary paint of approved brand and manufacture |
| 30 | Earth work in excavation by manual means over areas (exceeding 30 cm in depth,1.5 m in width as well as 10 sqm on plan) including getting out and disposal ofexcavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soil |
| 31 | Dumping stone excluding cost of stones. in Horizontal on level |
| 32 | 15 mm cement plaster on the rough side of single or half brick wall of mix :1:4 (1 cement: 4 fine sand) |
| 33 | Taking out the existing ceiling Fan with complete job, instruted as per site engineer incharge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 08, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysOct 19, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender