| Sl. No. | Item Description |
| 1 | Excavating trenches of required width for pipes cables etc in/c excavation for sockets and dressing of the sides where required ,ramming of bottoms, depth up to 1.5m in/c getting out excavated soil and backfilling of soil as required after laying of pipe line, layers not exceeding 20cm in depth in/c consolidating each deposited layer by ramming, watering and disposing of surplus excavated with all required leads as per chapter 2 of CPWD specifications and direction of the engineer-in-charge.A. For UPVC pipes in new work.a. In all kinds of soil. |
| 2 | i. For pipes not exceeding 90 mm dia |
| 3 | ii. For pipes exceeding 90 mm dia but not exceeding 300 mm dia |
| 4 | B. For G.I. / C.I. / D.I. pipes in new worka. In all kinds of soilI, For pipes not execeeding 90 mm dia. |
| 5 | ii. For pipes exceeding 90 mm dia but not exceeding 300 mm dia |
| 6 | Providing & laying of flexible PVC pipe (conforming to IS:7634) complete as per specification and directio of the Engineer in chare. |
| 7 | i)15 mm dia. |
| 8 | Providing, fixing and laying rigid UPVC pipes conforming to IS : 4985 jointing with couplers, of same class conforming to IS : 10124 ( Pt-II ) with solvent cement conforming to IS : 14182 including testing of joints complete ( but excluding the cost of specials like bend, tees etc. which will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge.A. Class - 3 ( working pressure 6.0 kg / cm2) |
| 9 | i. 40 mm OD |
| 10 | ii. 50 mm OD |
| 11 | iii. 63 mm OD |
| 12 | v. 90 mm OD |
| 13 | vi. 110 mm OD |
| 14 | vii. 140 mm OD |
| 15 | Providing fixing & laying fabricated UPVC socket/Coupler conforming to IS:10124(pary-2) with solvent cement conforming to IS:14182 in/c testing of joints complete as per CPWD specification and direction of the Engineer in charge. |
| 16 | i. 90 mm dia |
| 17 | ii. 110 mm dia |
| 18 | iii. 140 mm dia |
| 19 | Providing and laying S & S Centrifugally Cast ( Spun ) Ductile Iron Class K-7 Pipes conforming to IS : 8329 as per CPWD specification and direction of the Engineer - in - charge. |
| 20 | i 80 mm dia Ductile Iron Class K-7 pipes. |
| 21 | ii. 100 mm dia Ductile Iron Class K-7 pipes. |
| 22 | iii. 125 mm dia Ductile Iron Class K-7 pipes. |
| 23 | iv. 150 mm dia Ductile Iron Class K-7 pipes. |
| 24 | Providing and fixing DI specials as per CPWD specification and direction of the Engineer - in - charge.A. D.I. all socketted Bend 90 degree |
| 25 | i. 80 mm dia |
| 26 | ii. 100 mm dia |
| 27 | iii. 150 mm dia |
| 28 | B. D.I. all socketted Bend 45 degreei. 80 mm dia |
| 29 | ii. 100 mm dia |
| 30 | iii. 125 mm dia |
| 31 | iv. 150 mm dia |
| 32 | F. D.I. all socketted teei. 80 x 80 x 80 mm dia |
| 33 | ii. 100 x 100 x 80 mm dia |
| 34 | iii. 100 x 100 x 100 mm dia |
| 35 | iii. 125 x 125 x 80 mm dia |
| 36 | iv. 150 x 150 x 80 mm dia |
| 37 | v. 150 x 150 x 100 mm dia |
| 38 | vi. 150 x 150 x 150 mm dia |
| 39 | I. D.I. Double Socketted tapperi. 100 x 80 mm dia |
| 40 | ii. 125 x 80 mm dia |
| 41 | iii. 125 x 100 mm dia |
| 42 | iv. 150 x 80 mm dia |
| 43 | v. 150 x 125/100 mm dia |
| 44 | J. D.I. Flanged Socketted tail piecei. 80 mm dia |
| 45 | ii. 100 mm dia |
| 46 | iii. 125 mm dia |
| 47 | iv. 150 mm dia |
| 48 | K. D.I. Flanged Spigotted tail piecei. 80 mm dia |
| 49 | ii. 100 mm dia |
| 50 | iii. 125 mm dia |
| 51 | iv. 150 mm dia |
| 52 | Providing and fixing G.I. pipes of Heavy class as per IS : 1239 with latest amendment complete with G.I. fittings including trenching and refilling, cutting and making good the walls etc. complete as per CPWD specification and direction of the Engineer - in - charge.A. External work. |
| 53 | i. 15 mm dia. nominal bore |
| 54 | v. 40 mm dia. nominal bore |
| 55 | viii. 80 mm dia. nominal bore |
| 56 | ix. 100 mm dia. nominal bore |
| 57 | xi. 150 mm dia. nominal bore |
| 58 | Providing & fitting fixing GI flanged(10mmwall thickness) by welding with GI-MS pipe and placning position as per direction of the Engineer in charge. |
| 59 | i) 150 mm dia |
| 60 | iii) 100 mm dia |
| 61 | iv) 80 mm dia |
| 62 | providing,fixing & laying fabricated UPVC bend of reqd. degee confirming to IS 14182 including testing of joints complete as per chapter 20 of CPWD specification & direction of Engg. In Charge. |
| 63 | i. 40 mm dia. |
| 64 | ii. 50 mm dia. |
| 65 | iii. 63 mm dia. |
| 66 | v. 90 mm dia. |
| 67 | vi. 110 mm dia. |
| 68 | vii. 140 mm dia. |
| 69 | Providing, fixing and laying fabricated UPVC end cap conforming to IS : 10124 ( Part 4 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. |
| 70 | i. 40 mm dia. |
| 71 | ii. 50 mm dia. |
| 72 | iii. 63 mm dia. |
| 73 | v. 90 mm dia. |
| 74 | vi. 110 mm dia. |
| 75 | vii. 140 mm dia. |
| 76 | Providing, fixing and laying fabricated UPVC equal tee conforming to IS : 10124 ( Part 5 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in -charge. |
| 77 | i. 40 x 40 mm dia |
| 78 | ii. 50 x 50 mm dia |
| 79 | iii. 63 x 63 mm dia |
| 80 | v. 90 x 90 mm dia |
| 81 | vi. 110 x 110 mm dia |
| 82 | vii. 140 x 140 mm dia |
| 83 | Providing, fixing and laying fabricated UPVC straight reducer conforming to IS : 10124 ( Part 3 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. |
| 84 | i. 50 x 40 mm dia |
| 85 | ii. 63 x 50 mm dia |
| 86 | v. 110 x 90 mm dia |
| 87 | vi. 140 x 110 mm dia |
| 88 | vii. 140 x 90 mm dia |
| 89 | providing,fixing & laying fabricated UPVC tail piece with MS flange(8mm thick)of reqd. degee confirming to IS 14182 including testing of joints complete as per chapter 20 of CPWD specification & direction of Engg. In Charge. |
| 90 | v) 90 mm dia |
| 91 | vi)110 mm dia |
| 92 | vii)140 mm dia |
| 93 | Providing and fixing of CI non-return valve of approbed quality as per chapter clause 201 of CPWD and as per direction of Engineer in charge. |
| 94 | vi)150 mm nominal bore. |
| 95 | Providing & fitting, fixing CI sluice Valve class I (with cap) complete with nuts, bolts, rubber insertion etc. (the tail piece if required will be paid separetely) |
| 96 | iii) 80 mm dia |
| 97 | iv) 100 mm dia |
| 98 | v) 125 mm dia |
| 99 | vi) 150 mm dia |
| 100 | Providing & fixing bruss ferrule with CI cover conforming t0 IS:2692 in/c boaring and taping the main as per chapter 20 of CPWD specification and direction of Engineer in charge. |
| 101 | i) 10 mm nominal bore |
| 102 | Providing & fixing of GI socket as CPWD specification & direction of incharge. |
| 103 | i)15 mm nominal bore |
| 104 | Providing & fixing of GI bend/elbow in the pipe line as per CPWD specification and direction of Engineer in charge |
| 105 | i)15 mm dia |
| 106 | viii) 80 mm dia |
| 107 | ix)100 mm dia |
| 108 | xi)150 mm dia |
| 109 | Providing & fixing of GI union joints as per CPWD specification and direction of Engineer in charge |
| 110 | (i) 15mm dia |
| 111 | (v) 40 mm dia |
| 112 | (vi) 50 mm dia |
| 113 | Providing and fixing G.I. Reducer with the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. |
| 114 | vii. 40 x 15 mm dia |
| 115 | x. 50 x 15 mm dia |
| 116 | xxii. 80 x 40 mm dia |
| 117 | xxviii. 100 x 80 mm dia |
| 118 | xxxiv. 150 x 80 mm dia |
| 119 | xxxv. 150 x 100 mm dia |
| 120 | Providing and fixing G.I. Unequal Tee with the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. |
| 121 | vii. 40 x 40 x 15 mm dia |
| 122 | x. 50 x 50 x 15 mm dia |
| 123 | xxii. 80 x 80 x 40 mm dia |
| 124 | xxviii. 100 x 100 x 80 mm dia |
| 125 | xxxii. 150 x 150 x 100 mm dia |
| 126 | Providing & fixing GI Nipple of medium class as per chapter 20 of CPWD specification and direction of Engineer in charge. |
| 127 | (i) 15mm dia 75mm long |
| 128 | (ii) 15 mm dia 150mm long |
| 129 | Providing and fitting fixing PVC / plastic bib cock conforming to IS : 9763 in hydrant points at different location as per specification & direction of the Engineer-in-charge. |
| 130 | i) 15 mm dia PVC / plastic bib cock |
| 131 | Making road crossing by horizontal boring for smooth laying of UPVC / CI / DI / GI pipes etc. of required dia complete as per specification and the direction of the Engineer-in-charge. |
| 132 | B. by manual means. |
| 133 | Constructing masonry Chamber 90 x 90 x 100 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement: 4 fine sand) for sluice valve,with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 190 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1) cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design. |
| 134 | (i) With Second Class bricks. |
| 135 | Providing and fixing in position Precast RCC hydrant post of size 100 mm dia (made with reinforced cement concrete 1 : 1.5 : 3 (1 cement : 1.5 fine sand : 3 graded well burnt brick aggregate 1st class 12 mm nominal size) and steel reinforcement (TMT bars) 3 Nos. 8 mm dia 950 mm long and 7 Nos. 6 mm dia ties including plastering the surface with 6 mm thick cement mortar 1 : 3 (1 cement : 3 sand) finished with a floating coat of neat cement including providing & embedding 15 mm dia G.I. pipe (medium class as per IS : 1239) with necessary GI fittings like 2 Nos. elbow, 1 No. socket 2 Nos. nipple 225 mm long and fitting fixing of PVC bib cock with GI socket complete with all earth work required including refitting etc. complete as per approved drawing. Drawing No.06/CE/ACE/P&DU/DWS/2022-23). Specification and direction of the Engineer-in-charge. |
| 136 | Providing and fixing in position Precast RCC platform of size 900 mm x 900 mm x100 mm with curb of size 75 x 75 mm keping an opening of 200 mm wide for surface drain of 60 cm length of size (200 mmx150 mm) in a suitable place for draining out of grey water (made with cement concrete 1:1.5:3 (1 cement: 1.5 sand: 3 graded well burnt brick aggregate 12 mm nominal size) and steel reinforcement (TMT bars) 6 nos. 8 mm dia in both direction including plastering the exposed surface with 6 mm thick cement mortar 1:3 (1) cement :3 sand) for platform &12 mm cement plaster(1:4) (1 cement :4 sand) for surface drain finished with a floating coat of neat cement complete with all earth work required including refilling etc. complete as per approved drawing (Drawing No- 06/CE/ACE/P&DU/DWS/2022-23), specification and direction of Engineer-in- charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
TodayBid Opening Date
Technical bids will be opened and evaluated.
TodayTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender