Drinking Water Supply and Sanitation Government Departments Closing in 8 days TDR #57931439

Tender For Repair And Restoration Of Pump Control Panels And Electrical Accessories At Cwph Beechwal Under Pdr Sub Div.1St Bikaner

Issued by Government Departments · Bikaner, Rajasthan
Tender Value
4.73 Lakhs
Estimated cost
Bid Submission
26 Oct 2026
8 days left
EMD
9460
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bikaner → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair And Restoration Of Pump Control Panels And Electrical Accessories At Cwph Beechwal Under Pdr Sub Div.1St Bikaner

BOQ

Name of Work:- REPAIR AND RESTORATION OF PUMP CONTROL PANELS AND ELECTRICAL ACCESSORIES AT CWPH BEECHWAL UNDER PDR SUB DIV.1ST BIKANER
Sl. No. Item Description
1Part A :-
2PROVIDING AND FIXING OF SOFT STARTER IN EXISTING PANEL 110 KW
3Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 70.0 Sq. mm - 3.5 core
4Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 3 pole Power contactors with following AC 3 Rating - 250 Amp
5Providing & Fixing of thermal over load relay with built in single phase protection and having at least 1NO & 1NC contacts, manual /auto reset facility including making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . - 66 to 110 Amp
6Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator with standard short circuit withstand capacity , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . - Electrolytic grade (Cu-ETP) Tin Coated annealed copper bus bars IACS 100% grade
7Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type (up to 500) V range Volt meter / Direct- Ammeter / CT oertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracy as per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . - Three phase Ammeter with Inbuilt Selector Switch
8Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type (up to 500) V range Volt meter / Direct- Ammeter / CT oertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracy as per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . - Three phase Voltmeter with Inbuilt Selector Switch Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57931439
AUTHORITY Government Departments
TENDER VALUE 4.73 Lakhs
LAST DATE 26-10-2026
Authority
Authority Name Public Health Engineering Department
Work Description Tender for Repair And Restoration Of Pump Control Panels And Electrical Accessories At Cwph Beechwal Under Pdr Sub Div.1St Bikaner
Basic Detail
Tender No EE/PHED/PDR1/BKN/43
Bidding Type Tender
Location
City Bikaner
State Rajasthan
Key Dates
Publish Date 08 Oct 2026
Submission Date 26 Oct 2026
Open Date 27 Oct 2026
Finance
Tender Value 4.73 Lakhs
Tender Fee 500
EMD 9460
Exemption Available
Document List
43.pdf
BOQ_1070206.xls
cff02785-f716-4c32-8321-50b162b7f660.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 08, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 26, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Oct 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
pdf

43.pdf

xls

BOQ_1070206.xls

html

cff02785-f716-4c32-8321-50b162b7f660.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender