Tender For Provision Of Stand By Power Supply To Lifts Of Druva (P-20) And Eklavya (P-39) Building Enc(O) Mess Complex Under Age E/M No-I Of Ge (U-I) Visakhapatnam
Tender Overview
Project Description
Tender for Provision Of Stand By Power Supply To Lifts Of Druva (P-20) And Eklavya (P-39) Building Enc(O) Mess Complex Under Age E/M No-I Of Ge (U-I) Visakhapatnam
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 13-Oct-2026 | Corrigendum1 | Other | 29-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Supply, installing, testing and commissioning of 58.5 KVA Diesel Engine driven Generating set, silent type with alternator output Voltage 415 Volts +/- 1% at set value of 415 V at a frequency 50HZ +/-0.5% with suitable standard control panel, all mounted in acoustic enclosure and AMF panel as per manufacturers design and specification as per approved CPCB-04 norms OR latest norms during execution confirming to the detailed specifications appended below and (1.01 & 1.02) :-(a) General: Suitable four stroke compressed ignition, radiator water cooled, Turbocharged aspiration, continuous duty with 10% overload capacity for any one hour in 12 hours running, 50°C intake air temperature, CPCB-04 approved Engine developing Suitable BHP at 1500 RPM coupled to alternator mounted on Channel Iron base frame with in-built fuel tank of OEM recommended capacity. The prime mover provided should be as per IS specifications.(b) Air intake system: Should comprise of dry type intake air filter mounted on engine, one in number vacuum indicator mounted on intake piping.(c) Exhaust System: Should comprise of one exhaust manifold, dry type, mounted on engine, one exhaust silencer which should be positioned in such a way that the exhaust gas is not sucked by the fan on the radiator, thereby affecting the cooling system. The silencer should cater to the noise level tolerance prescribed in the relevant IS/BS. The silencer should be provided with flaps with a provision so that it will open only when the generator is running. The complete exhaust system shall be properly supported so that entire lot of the exhaust system shall not fall on the DG Set. (Contd...) Please Enable Macros to View BoQ information |
| 2 | Supply, installing, testing and commissioning of 58.5 KVA Diesel Engine driven Generating set, silent type with alternator output Voltage 415 Volts +/- 1% at set value of 415 V at a frequency 50HZ +/-0.5% with suitable standard control panel, all mounted in acoustic enclosure and AMF panel as per manufacturers design and specification as per approved CPCB-04 norms OR latest norms during execution confirming to the detailed specifications appended below and (1.01 & 1.02) :-(a) General: Suitable four stroke compressed ignition, radiator water cooled, Turbocharged aspiration, continuous duty with 10% overload capacity for any one hour in 12 hours running, 50°C intake air temperature, CPCB-04 approved Engine developing Suitable BHP at 1500 RPM coupled to alternator mounted on Channel Iron base frame with in-built fuel tank of OEM recommended capacity. The prime mover provided should be as per IS specifications.(b) Air intake system: Should comprise of dry type intake air filter mounted on engine, one in number vacuum indicator mounted on intake piping.(c) Exhaust System: Should comprise of one exhaust manifold, dry type, mounted on engine, one exhaust silencer which should be positioned in such a way that the exhaust gas is not sucked by the fan on the radiator, thereby affecting the cooling system. The silencer should cater to the noise level tolerance prescribed in the relevant IS/BS. The silencer should be provided with flaps with a provision so that it will open only when the generator is running. The complete exhaust system shall be properly supported so that entire lot of the exhaust system shall not fall on the DG Set. (Contd...) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
TodayBid Submission Deadline
Online submission via eProcurement portal.
TodayTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender