Power Government Departments Closing in 0 days TDR #57929717

Tender For Augmentation Of Receiving Station Hyhama From 1X10 Mva To 2X10 Mva Under Ut Capex

Issued by Government Departments · Kupwara, Jammu and Kashmir
Tender Value
90.58 Lakhs
Estimated cost
Bid Submission
02 Nov 2026
0 days left
EMD
1.81 Lakhs
Bank guarantee accepted
Document Fee
2003
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kupwara → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Augmentation Of Receiving Station Hyhama From 1X10 Mva To 2X10 Mva Under Ut Capex

BOQ

Name of Work:- Augmentation of Receiving Station Hyhama from 1x10 MVA to 2x10 MVA under UT Capex
Sl. No. Item Description
1Supply, Installation, Testing and Commissioning of
2Installation, testing and successful commissioning of 10 MVA Power Transformer including loading at ECSD Pampore, handling, Carriage upto site/ Unloading /Dragging /Assembling at site including insurance during transit (Complete Job) to Receiving Station ( Power Transformer to be provided by the Department)
3Supply, Carriage upto site (including Loading/Unloading),Installation,Testing & Commissioning of 33 kV VCB (36 kV, 1250A, 26.2 kA, Outdoor Type of reputed make as per approved drawings/standards
4Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 33 kV Isolator with Earthing Blade (36KV,800A,Outdoor,3 poles,25 KA) of reputed make as per approved drawings/standards (01 Set = 03 Number)
5Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 33 kV Isolator without Earthing Blade (36KV,800A,Outdoor,3 poles,25 KA) of reputed make as per approved drawings/standards (01 Set = 03 Number)
6Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 33 KV Current Transformer (33 KV, 1Φ, 2 Ratio 3 Core, Outdoor Type ; 300-150/5-5A) of reputed make including supply and fixing of suitable CT Clamps as per approved drawings/standards
7Supply, Carriage upto site (including Loading/Unloading),Testing of 11kV/ 110 V, Three phase epoxy resin cast Voltage Transformer with rated burden 15VA per phase and accuracy class 0.5 (reputed make)
8Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 33 kV Lightening Arrestors (33 kV, 10kA, Station class, ZnO, Polymer) gap less (1 No. per Φ) of reputed make as per approved drawings/standards
9Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 33 kV C&R Panel along with O/C, E/F,REF and differential relays (IEC61850), mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port
10Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 33 kV 10 kN Post Insulator Polymer 36kV,235kV Impulse, creepage distance 1224m of reputed make as per approved drawings/standards
11Supply, Carriage upto site (including Loading/Unloading),Testing and Erection of Steel Tubular Pole, 11 Mtr. Long Pole(ST-410 SP-56) with planting depth of 1/6 th of the height of the pole, (11 mtr. Long ) as per approved drawings/standards
12Supply & Laying of Cement bottoming for 11 Mtr ST Pole in 1:2:4 mix as per Standards 0.66 cum / pole including the Loading/Carriage/Unloading of required material.
13Providing & Fixing of Pole Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip.25x3mmas per approved drawings/standards
14Providing & Painting of 11 Mtr ST Poles with one coat of Red Oxide and two coats of aluminium paint as per approved drawings/standards
15Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of G.I Pipe of Dia 150mm, 5.9 mm Thick 3 m long with G.I Base Plate 8 mm Thick as per approved drawings/standards
16Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of GI Channel/Angle/Flat of sizes including clamps as per approved drawings/standards
17Supply,Testing,Loading,Carriage,Unloading and fixing of Galvanised Nuts & Bolts of sizes
18Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 12 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS( Polycab, Havells, KIE, Anchor or any other reputed make) as per approved drawings/standards
19Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 6 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS( Polycab, Havells, KIE, Anchor or any other reputed make) as per approved drawings/standards
20Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 4 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS( Polycab, Havells, KIE, Anchor or any other reputed make) as per approved drawings/standards
21Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 2 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS( Polycab, Havells, KIE, Anchor or any other reputed make) as per approved drawings/standards
22Supply & Fixing of Lugs, Ferrules etc.
23Supply, Carriage upto site (including Loading/Unloading),Testing and fixing of 200 mm² ACSR Conductor( Panther) as per approved drawings/standards
24Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fitting as per approved drawings/standards
25Supply, Carriage upto site (including Loading/Unloading) Testing & fixing of Earth wire 7/4.00 mm sq. as per approved drawings/standards
26Supply, Carriage upto site (including Loading/Unloading) Testing & fixing of GI flat for earthing (50x6) mm as per approved drawings/standards
27Supply, Carriage upto site (including Loading/Unloading) Testing & fixing of T Clamps as per approved drawings/standards
28Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 11 KV Outgoing SCADA Compatible VCB Panel Board (12 kV, 1250A, 25 kA-3 Sec, Indoor) with Numerical O/C, E/F relays confirming to IEC61850, Master Trip Relay, Mimic Diagram, Digital Voltmeter with VSS, Digital Ammeter with ASS, PF Meter, Annunciation Windows with annunciation relays(6-Windows), 3-phase Tri-vector meter -5 Amps DLMS Compliant with RS-485 port ,Double Ratio; Three Core(0.5,5P10,PS) Epoxy Casted CT with CTR :400-200/5-5A,TNC Switch, LR switch, Indication Lamps & other equipments as per approved Technical Specifications, of reputed make including Fixing of Earthing & Feeder Name Plate with Name of feeder written on it by using high intensity reflective Tape. (Reputed Make)
29Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 11 KV Incomer SCADA Compatible VCB Panel Board (12 kV, 1250A, 25 kA-3 Sec, Indoor) with Numerical O/C, E/F relays confirming to IEC61850, Master Trip Relay, Mimic Diagram, Digital Voltmeter with VSS, Digital Ammeter with ASS, PF Meter, Annunciation Windows with annunciation relays(6-Windows), 3-phase Tri-vector meter -5 Amps DLMS Compliant with RS-485 port ,Double Ratio; Three Core(0.5,5P10,PS) Epoxy Casted CT with CTR :600-300/5-5A,Epoxy Casted PT with PTR :11KV/110 V, TNC Switch, LR switch, Indication Lamps & other equipments as per approved Technical Specifications, of reputed make including Fixing of Earthing & Feeder Name Plate with Name of feeder written on it by using high intensity reflective Tape. (Reputed Make)
30Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 11 kV 630 mm² Single Core XLPE Cable armoured, FRLS (Havells/KEI/Polycab or any other reputed make ) as per approved drawings/standards
31Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 11 kV 3-Core XLPE 240 mm² armoured, FRLS (Havells/KEI/Polycab or any other reputed make ) as per approved drawings/standards
32Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 11kV Indoor Heat Shrinkable Cable Termination Kits suitable for 630 mm² Single Core XLPE Cable (3M/Vitchem or any other reputed brand) as per approved drawings/standards
33Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 11kV Outdoor Heat Shrinkable Cable Termination Kits suitable for 630 mm² Single Core XLPE Cable (3M/Vitchem or any other reputed brand) as per approved drawings/standards
34Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 11kV Indoor Heat Shrinkable Cable Termination Kits 3C- 400 mm² (3M/Vitchem or any other reputed brand) as per approved drawings/standards
35Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 11 kV Outdoor Heat Shrinkable Cable Termination Kits 3C- 400 mm² (3M/Vitchem or any other reputed brand) as per approved drawings/standards
36Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 11 kV Isolator, Double Break,3-pole, 630 Amp, horizontal mounting Type, with Earth Switch. as per approved drawings/standards
37Supply, Carriage upto site (including Loading/Unloading),Testing & laying of HDPE Pipe Outer Dia 160 mm Inner Dia 148 mm for 11kV XLPE Cable from Power Transformer to Control Room including excavation as per approved drawings/standards
38Supply & Laying of Reinforced cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 20 mm nominal size for Transformer Bed foundation (3mx2.5mx1.5m) including Excavation of existing Earth,centering shuttering works, 15mm plastering (1:6),Curing, TMT Bars,Back Filling of Existing earth as per the requirement,Speading of Extra Soil in available space as per the directions of Engineer Incharge & Loading/Carriage/Unloading of required material (The job should be executed strictly as per approved KPDCL Drawings)
39Supply & Laying of Reinforced cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 20 mm nominal size for Equipment Foundation and Gantry Foundation including Excavation of existing Earth,centering shuttering works, 15mm plastering (1:6),Curing, TMT Bars,Back Filling of Existing earth as per the requirement,Speading of Extra Soil in available space as per the directions of Engineer Incharge & Loading/Carriage/Unloading of required material (The job should be executed strictly as per approved KPDCL Drawings)
40Supply, Carriage upto site (including Loading/Unloading), Fabrication, Installation & Testing of Earthing Mat (GI Flat 50mm x8 mm) as per approved drawings/standards (Joints should be welded properly and painting of joints to be carried out by using Red Oxide and Deeco Paint. The job includes the excavation of existing earth to the depth as per the KPDCL standards in vogue and back filling of good earth upto ground level after fixing the earth mat including spreading of extra soil in available space as per the directions of Incharge Engineer
41Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of Earthing Electrode ( 3m long 40mm dia GI pipe) including their jointing to earthing mat through GI Strip (50x6)mm by welding/bolting and painting of joints with Red Oxide and Deeco Paint as per approved drawings/standards
42Supply & Laying of Yard concrete in 1:2:4 mix (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 20 mm nominal size ) including excavation of earth as per the requirement, centering shuttering,Spreading of extra soil in available space as per the directions of Incharge Engineer & Loading/Carriage/Unloading of required material.
43Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of Yard Lighting by way of Providing 12.5 Mtr motorised High Mast with 4 No.s of 200 W LED flood lights (Bajaj/Havells/Syska/Wipro or any other eputed make) on each High Mast .The job includes provding and fixing of control panel containing all protective equipments (like surge arrestor, MCB,over volrage protection, Timer), complete wiring and Construction of Foundations using reinforced concrete including TMT Bars (3 Cums) as per the drawings/standards
44Supply, Laying & Spreading of Yard Metal by way of stone aggregate 20 mm nominal size including the Loading/Carriage/Unloading of required material.
45Providing & Construction of 500 m Cable Trench by laying of Reinforced cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 20 mm nominal size including Excavation of existing Earth,Centring shuttering works, Angle Iron and TMT Bars as per the KPDCL standards, 15mm plastering (1:6), fabrication,Back Filling of Existing earth as per the requirement,Speading of Extra Soil in available space as per the directions of Engineer Incharge,Fixing of 8 mm thick chequered plates & Loading/Carriage/Unloading of required material as per the drawings/standards
46Supply, installation, testing and commissioning of 1.5 HP submersible pump set suitable for water pumping, complete with submersible motor, pump, delivery pipe connection, necessary cables, starter/control panel board with overload and short-circuit protection, level control arrangement and all accessories required for satisfactory operation, including all labour and incidentals.
47Supply, Carriage upto site (including Loading/Unloading),Installation,Testing & Commissioning of Battery Bank 36 V,200 AH , of 18 No. cells of 2 V each, sealed maintenance free VRLA type,High impact Polyprophelene copolymer container,flame retardant (reputed make) as per approved drawings/standards
48Supply, Carriage upto site (including Loading/Unloading),Installation,Testing & Commissioning of 36V, 200 AH , Float-Cum-Boost Charger With Full wave rectification for 220 V, 1Phase, 50 HZ AC Input Supply (reputed make) as per approved drawings/standards
49Supply, Carriage upto site (including Loading/Unloading) & Fixing of Rubber Mat 1mx2m 19mm thick as per approved drawings/standards
50Supply, Carriage upto site (including Loading/Unloading) & Fixing of Fire Extingiusher Co₂ Type of 4.5 kg capacity for Control room as per approved drawings/standards
51Supply , installation and testing of Fire Fighting Equipment (3 No. Fire Buckets of 9 ltrs,having round bottom with handle, painted white from inside and post office red colour from outside , bottom is painted black. Filled with sand.
52Supply, and Carriage upto site (including Loading/Unloading) of 33kV level Rubber Gloves as per relevant IS/standards
53Supply, and Carriage upto site (including Loading/Unloading) of 11kV level Rubber Gloves as per relevant IS/standards
54Supply, and Carriage upto site (including Loading/Unloading) of Safety Shoes (Ankle Boot) as per relevant IS/standards
55Supply, and Carriage upto site (including Loading/Unloading) of Earthing Discharge rod 5 mtr long with 25 sq mm cable 12 mtr as per relevant IS/standards
56Supply of electrical safety helmet suitable for use during operation and maintenance of 11 kV and 33 kV electrical lines, made of high-impact insulating material, non-ventilated type, with adjustable suspension/harness, chin strap and complete with all accessories, conforming to relevant BIS/IS standards for electrical protection and suitable for the specified voltage levels.
57Supply of ISI-marked safety/industrial helmet with adjustable head suspension and chin straps, complete with headlamp bracket and detachable/interchangeable rechargeable LED headlamp, including rechargeable battery and charger/charging facility, suitable for use in electrical and industrial works, conforming to relevant BIS/IS standards, complete in all respects
58Supply, and Carriage upto site (including Loading/Unloading) of Safety Belt as per relevant IS/standards
59Supply, Testing and Carriage upto site (including Loading/Unloading) of Telescopic Aluminium Ladder 18' long as per relevant IS/standards
60Supply, Testing and Carriage upto site (including Loading/Unloading) of Aluminium Ladder 2x20' long, 3 mm thick extendable with rope and pully arrangement as per relevant IS/standards
61Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of CCTV Complete(LED 32\\" with 06 No.AHD Cameras) of reputed make.
62Supply, Testing and Carriage upto site (including Loading/Unloading) of HV Detectors all voltages along with attached fiber rod as per relevant IS/standards
63Spares/Contengencies/T&P Items
64Hiring of Vehicle (Scorpio/Bolero/Innova/Tavera or equivalent) to be used by the Engineer Incharge for supervision of the project including Fuel/Toll Tax/ Driver/ any other maintenace charges of the vehicle. The max. Kms to be driven per day is 120 Km. In case the vehicle is utilized less than 120 km on any given day, the payment shall be subject to deduction on account of actual fuel savings. Such deduction shall be worked out proportionately based on the approved mileage (km per litre) of the vehicle and the prevailing fuel rate.
65Supply, installation, testing and commissioning of 10 kVA servo-controlled automatic voltage stabilizer, 3-phase/4-wire, complete with servo motor, control circuit, digital voltage display, input/output MCB/MCCB, overload and short-circuit protection, suitable for continuous operation, with necessary accessories and complete in all respects.
66Supply, Carriage upto site (including Loading/Unloading), Testing of Heavy Duty 4-Stroke Engine Brush Cutter 35cc Petrol Engine Jacket belt fitted for hassle operation (Honda/Bosch or equivalent)
67Supply, Carriage upto site (including Loading/Unloading),Testing of 12 KV, Three Core(0.5,5P10,PS) Epoxy Casted CT with CTR :400-200/5-5A; 600-300/5-5A
68Supply, installation, testing and commissioning of A4 Monochrome LaserJet Printer, minimum 30 PPM, 1200 × 1200 dpi, automatic duplex printing, USB/Ethernet connectivity, complete with all standard accessories and one-year warranty (HP/ Canon/ Epson or equivalent) (to be provided at Divisional Office)
69Supply, installation, testing and commissioning of wall-mounted RO water purifier with RO+UF purification technology, UV LED, TDS control and built-in TDS meter, having 8 litre storage tank and minimum 20 LPH purification capacity, with automatic shut-off facility, suitable for continuous operation, complete with all necessary filters, fittings, tubing, electrical connections, mounting accessories and charger/power supply, complete in all respects Aquaguard/Kent/Urban or equivalent make
70Supply, Carriage upto Divisional Stores Amargarh (including Loading/Unloading) of Stock Register long having 300 pages as per prescribed format Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57929717
AUTHORITY Government Departments
TENDER VALUE 90.58 Lakhs
LAST DATE 02-11-2026
Authority
Authority Name Power Development Department
Work Description Tender for Augmentation Of Receiving Station Hyhama From 1X10 Mva To 2X10 Mva Under Ut Capex
Basic Detail
Tender No STDS/23 of 2026-27
Bidding Type Tender
Location
City Kupwara
State Jammu and Kashmir
Key Dates
Publish Date 08 Oct 2026
Submission Date 02 Nov 2026
Open Date 04 Nov 2026
Finance
Tender Value 90.58 Lakhs
Tender Fee 2003
EMD 1.81 Lakhs
Exemption Not Available
Document List
0073920a-16d6-473b-b3c6-f0d709e50b61.html
BOQ_1108292.xls
Drawing.pdf
SBD23.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 08, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Nov 04, 2026

Bid Opening Date

Technical bids will be opened and evaluated.