Rural Development Government Departments Closing in 4 days TDR #57929564

Tender For Internal Electrification Of 100 Seated Boys Hostel At Khedacherra High School Under R.D. Damcherra Sub Division During The Year 2026-27.

Issued by Government Departments · tripura, Tripura
Tender Value
10.24 Lakhs
Estimated cost
Bid Submission
15 Oct 2026
4 days left
EMD
20482
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
tripura → Tripura
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Internal Electrification Of 100 Seated Boys Hostel At Khedacherra High School Under R.D. Damcherra Sub Division During The Year 2026-27.

BOQ

Name of Work:- INTERNAL ELECTRIFICATION OF 100 SEATED BOYS HOSTEL AT KHEDACHERRA HIGH SCHOOL UNDER R.D. DAMCHERRA SUB DIVISION DURING THE YEAR 2026-27.
Sl. No. Item Description
1Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:-.a) Short Point :-
2Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:-Medium Point :-
3Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:-Long Point :-
4Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modular switch board, earthing the 3rd pin etc. as required:-
5Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required:-
6Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required.2 X 1.5 sq mm
7Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required. 2 X 2.5 sq mm
8Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required.2 X 4 sq mm
9Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required.4 X 6 sq mm
10Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required.4 X 10 sq mm
11Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:-1 X 1.5 sq mm
12Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:- 1 X 2.5 sq mm
13Supplying and fixing of the following sizes PVC conduit (medium gauge) on surface with all accessories etc. as required.19/20 mm dia
14Supplying and fixing of the following electrical accessories including necessary connection etc. as required.15 amps power top:-
15Supplying and fixing of the following modular accessories including necessary connection etc. as required.32 amps one way DP switch (2M):-
16Supplying and fixing of the following modular accessories including necessary connection etc. as required.4 step fan regulator (1M):-
17Supplying and fixing of the following modular accessories including necessary connection etc. as required.Blank plate (1M):-
18Supplying and fixing of the following modular accessories including necessary connection etc. as required.20/25 amps single phase motor starter switch (2M):-
19Earthing with Copper earth plate 600 mm x 600 mm x 3 mm thick i/c accessories and providing masonry enclosure with CI cover plate Size 12\\"x 12\\" having locking arrangement, along with 20 mm dia (medium gauge) watering pipe including CC work etc as required:-
20Extra for using salt (12 kg) and charcoal (96kg) for plate earth electrode as required.
21Providng and laying 15mm dia(medium gauge) G.I. pipe for drawing of 4.06mm (8SWG) dia G.I./ Copper wire for earth connection from earth electrodes etc as required.
22Supply and fixing of 25mm x 3mm Copper on walls/ floor of the building for horizontal/ vertical network including necessary spacers and porcelain insulators at regular intervals.
23Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/minimum service value 4.0 m3/min/W) : -
24Supplying & installation of 225/230 mm sweep metalic body exhaust fan including connection etc as required:-
25Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required:-
26Making different sizes of hole in the wall for fixing of exhaust fan including finishing the same with cement plastering and painting etc as required:
27Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):-Recessed/Surface mounted 1ft x 1ft decorative 16/18 watt LED panel light with integral driver and high quality polycarbonate diffuser:-
28Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):-Surface mounted round/Square shaped 12 watt LED downlight with integral driver and high quality polycarbonate diffuser:-
29Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):-45 watt LED street light fixture with integral driver and secondary lens (IP 66):-
30Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:-18/20 watt LED tube with integral driver and polycarbonate diffuser (50000 burning hours and minimum lumen output of 100lm/watt):-
31Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:-14 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :-
32Supplying and installation of Bus bar chamber of the following ratings and sizes made of steel sheet enclosure with all accessories including necessary connection etc. as required:-63 amps 415 volts four strip Copper busbar chamber 4 ways of size (330mmx280mmx100mm):-
33Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required:-63 amps 415 volts TPN main switch (rewireable):-
34Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required.(2+6) / 8 way SPN MCB DB (double door):-
35Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required.6 way horizontal TPN MCB DB (Double door):-
36Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connection as required:-6 to 32 amps SP MCB:-
37Supplying & installation of isolators of following ratings in the existing MCB DB including connection etc as required:-40 amps DP isolator:-
38Supplying & installation of isolators of following ratings in the existing MCB DB including connection etc as required:-63 amps FP isolator:-
39Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required3 core 4 Sq mm
40Supplying and fixing of thermoplastic cable junction box with connectors suitable for following sizes cable : -1.5 sqmm - 4 sqmm Cable:-
41Supplying and fixing of aluminium terminal ends (LUGS) - long barrel of following sizes : -4/6 sq mm
42Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:-25 mm dia
43Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 nos legs (25mmx25mmx5mm MS angle 20 cm long) finished with red oxide and 2 coat synthetic enamel paint including necessary cc work, mending the damages & painting etc as required:-
44Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement- 1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size):-
45Centering shuttering including struttings, propping etc.and removal of form work for: Foundations, footings, bases for columns etc. for mass concrete with timber plank:-
46Supplying, installation, testing and commissioning of following ratings inverter with Square/ sine wave technology, noiseless operation, inbuilt advance PCB programming, microprocessorwith all accessories including necessary connections etc. as required:-900VA, 12V DC, 1 Ph input/1 Ph output inverter(Sine wave technology):-
47Supplying, installation, testing and commissioning of following ratings Valve regulated lead acid(VRLA) battery with all accessories including necessary connections etc. as required:-12 V/ 200AH tall tubular/ flat plate Battery:- Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57929564
AUTHORITY Government Departments
TENDER VALUE 10.24 Lakhs
LAST DATE 15-10-2026
Authority
Authority Name Rural Development Department
Work Description Tender for Internal Electrification Of 100 Seated Boys Hostel At Khedacherra High School Under R.D. Damcherra Sub Division During The Year 2026-27.
Basic Detail
Tender No eDT40/EE/RD/KCP/DIV/2026-27
Bidding Type Tender
Location
City tripura
State Tripura
Key Dates
Publish Date 08 Oct 2026
Submission Date 15 Oct 2026
Open Date 15 Oct 2026
Finance
Tender Value 10.24 Lakhs
Tender Fee 1000
EMD 20482
Exemption Not Available
Document List
40EEAPPROVEDDNIT.pdf
4a5abe13-d5aa-448a-b5f5-8b4c8a4d9a2a.html
BOQ_79243.xls
DRAWING.pdf
ePT14.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 08, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Oct 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
pdf

40EEAPPROVEDDNIT.pdf

html

4a5abe13-d5aa-448a-b5f5-8b4c8a4d9a2a.html

xls

BOQ_79243.xls

pdf

DRAWING.pdf

pdf

ePT14.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders