Communications and Information Technology Government Departments Closing in 20 days TDR #57929004

Tender For Supply, Installation, Testing And Commissioning Of Automatic Fire Sprinkler System And Replacement Of Pipes Of Fire Fighting Wet Riser System In Sanchar Bhawan , New Delhi.

Issued by Government Departments · New Delhi, Delhi
Tender Value
1.59 Crore
Estimated cost
Bid Submission
30 Oct 2026
20 days left
EMD
3.18 Lakhs
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Supply, Installation, Testing And Commissioning Of Automatic Fire Sprinkler System And Replacement Of Pipes Of Fire Fighting Wet Riser System In Sanchar Bhawan , New Delhi.

BOQ

Name of Work:- Supply, Installation, Testing and Commissioning of Automatic Fire Sprinkler System and Replacement of pipes of Fire fighting Wet Riser System in Sanchar Bhawan , New Delhi.
Sl. No. Item Description
1(a) Supplying, installation, testing and commissioning of Electric driven Main Fire Pump conforming to IS 12469: 2019 having minimum efficiency of 65% suitable for automatic operation and consisting of following, complete in all respects, as required :(b) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal as required.(c) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-12615: 2018.(d) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.(e) Suitable cement concrete foundation duly plastered with anti vibration pads.
22850 lpm at 88 m Head
3(a) Supplying, installation, testing and commissioning of electric driven pressurization pump conforming to IS 12469: 2019 having minimum efficiency of 50% suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)(b) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal as required. (c) Suitable HP squirrel cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-12615: 2018.(d) M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.(e) Suitable cement concrete foundation duly plastered and with anti vibration pads.
4180 lpm at 88 m Head
5Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required
6200 mm dia
7150 mm dia
880 mm dia
965 mm dia
10Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required
11200 mm dia
12150 mm dia
1380 mm dia
1450 mm dia
1525 mm dia
16Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.
17200 mm dia
1880 mm dia
19Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of following sizes as required:
20150mm dia
21Providing and fixing in position industrial type pressure gauges with gun metal / brass valves complete etc. as required
22CONTROL PANELFabrication, supply, Installation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :
23INCOMING250A, 50kA 4 Pole MCCB, Ics=100% Icu ratingDigital Voltmeter 0-500V with selector switchDigital Ammeter (0-250 A) with selector switch & CTs etc.LED type RYB phase indicating lamps, ON, OFF, trip indicating lampsSet of Copper Bus Bar 300AOUTGOING( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)Main Fire Pump125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required forautomatic operation, selector switch for local/remote, auto/manual/OFF operation.Jockey Pump63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automaticoperation, selector switch for local/remote, auto/manual/OFF operation.Diesel Engine ControlControl for diesel engine comprising -Automatic/Manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System ControllerDesigning, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification
24Supply and fixing of XLPE insulated, PVC sheathed following conductor 1.1 KV grade armoured Cable of following sizes including making end termination with brass double compression gland & bimetallic lugs, cable tray with hanger and support etc.complete as required
253.5 × 50 sq.mm.(aluminium)
264 x 25 sq.mm.(aluminium)
274C X 1.5 sq.mm.Cu
282CX 1.5 sq.mm.Cu
29Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
30Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
31Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastner etc as required.
32100 mm width X 50 mm depth X 1.6 mm thickness
33200 mm width X 50 mm depth X 1.6 mm thickness
34Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastner etc as required.
35100 mm width X 50 mm depth X 1.6 mm thickness
36200 mm width X 50 mm depth X 1.6 mm thickness
37Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastner etc as required.
38100 mm width X 50 mm depth X 1.6 mm thickness
39225 mm width X 50 mm depth X 1.6 mm thickness
40Supplying and installing following size of perforated painted with powder coating M.S. cable trays cross member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastner etc as required.
41100 mm width X 50 mm depth X 1.6 mm thickness
42225 mm width X 50 mm depth X 1.6 mm thickness
43Supplying, installation, setting, testing and commissioning of differential type pressure switches with one NO+ 1 NC contact 220 volts 5 amp and pressure rating 10 Kg//sq.cm for operation of fire pumps With wiring and its termination
44Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required.Note : 1. All pipes and fittings will be installed with help of threaded joints only .2. Welding is allowed in the pipes wherever approved by the Engineer in Charge. 3. Firestops: For all horizontal and vertical crossings of building structure ( slabs, walls, beams, column etc.) pvc pipe sleeves of dia atleast 30 mm more than the dia of the pipe to be passed through shall be fixed in the building structure, the space between the sleeve and the structure shall be made good. The annular space between the pipe and the sleeves shall be sealed with fire resistant acrylic based sealant of approved make and quality.
4525 mm dia
4632 mm dia
4750 mm dia
4865 mm dia
4980 mm dia
50100 mm dia
51150 mm dia
52200 mm dia (wall thickness 6.3 mm)
53Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 suitable for ductile iron groove fitting including groove fittings with accessories , fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. making connection with existing pipework, fixing the pipe on the wall/ceiling with suitable clamp/support pipework on walls, beams, slabs, columns etc. with M. S. supports (duly painted), adjustable hangers, frame and painting with two or more coats of synthetic enamel paint of required shade complete as requiredNote : 1. Only Ductile Iron Groove Fittings for pipes all dia . Rigid & Flexible Coupling shall be installed whever required2. No welding is allowed in the pipes unless approved by the Engineer in Charge. 3. The Grooving in the pipes should be done by the compatible Grooving Machine approved by the manufacturer of grooved fittings.4. Firestops: For all horizontal and vertical crossings of building structure ( slabs, walls, beams, column etc) pvc pipe sleeves of dia atleast 30 mm more than the dia of the pipe to be passed through shall be fixed in the building structure, the space between the the sleeve and the structure shall be made good. The annular space between the pipe and the sleeves shall be sealed with fire resistant acrylic based sealant of approved make and quality.
5465 mm dia
5580 mm dia
56100 mm dia
57150 mm dia
58Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : (NWAGE/ TYCO)
59Pendent Sprinkler
60Upright Sprinkler
61Horizontal side wall sprinkler
62Concealed sprinkler
63Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.
641000 MM long
651200 MM long
661500 MM long
67Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required
68Providing and fixing, in position concealed G.I. section for wall paneling using board of required thickness fixed on the ‘W’ profile (0.55 mm thick) having a knurled web of 51.55 mm and two flanges of 26 mm each with lips of 10.55 mm, placed @ 610 mm C/C in perimeter channel having one flange of 20 mm and another flange of 30 mm with thickness of 0.55 mm and web of length 27 mm. Perimeter channel is fixed on the floor and the ceiling with the nylon sleeves @ 610 mm C/C with fully threaded self-tapping dry wall screws. Board is fixed to the ‘W’ profile with 25 mm countersunk ribbed head screws @ 200 mm C/C., all complete as per the drawing & directions of engineer-in-charge, the joints of the boards are finished with specially formulated jointing compound and 48 mm wide jointing tape to provide seamless finish.Plain Gypsum plaster board conforming to IS: 2095 Part -1:2011 (Board with BIS certification marks)- 12.5 mm thick
69Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595 mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ≥ 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32 mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8 mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.60)
70Finishing with Deluxe Multi surface paint system for interiors and exteriorsusing Primer as per manufacturers specifications :Two or more coats applied on walls/ceiling @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm
71Dismantling tile work of thickness of tiles 10 mm to 25 mm in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
72SITC of Air Release Valve in the existing sprinkler system etc complete as required
73Supply, erection, testing and commissioning ball valve with hard chrome plated ball (PN-16) inside PTFE (Teflon) seat & ring with chrome plated center handle with female BSP threads complete in all respects.
7425 mm dia
7540 mm dia
7650 mm dia
77Supply, erection, testing and commissioning UL listed and FM approved water flow detectors / switches (Vane type) for sprinkler system, shall have sensitivity in the range of 4 to 10 US gallon per minute and static pressure rating of 450 PSI including accessories, junction box, suitable for indoor / outdoor mounting. The detector shall respond to water flow in the specified direction after a preset time delay that is field adjustable, complete as required suitable for fixing on fire pipe including connection for wiring.
7880 mm dia
79100 mm dia
80150 mm dia
81Supply, erection, testing and commissioning of drain assembly for installation on Sprinkler System, in brass body consisting of steel single lever ball valve for multiple test and drain functions, including inlet connection of specified size, sight glass, connections to the main header and line drain complete as per requirements. Product shall suitable for min.16 kg/cm2 working pressure and shall be UL Listed / FM Approved
8250mm Drain size and 15mm (5.6K) Testing Orifice
83Note: 1. The evaluation of the tender will be on QCBS (Quality and Cost-Based Selection) Evaluation Methodology , Bidders are advised to go through the procedure as per para 4 of Section 2 mentioned on page no. 7 .2. The contractor shall first carry out a preliminary site survey of Sanchar Bhawan before quoting the rates and read the Precautionary Instructions, Safety Requirements and Care to be Taken by the Agency attached at Para 18 of Sec 3 Part A . 3. The Agency shall get prior approval before execution of the work i/c preperation of floor-wise( Basement , G+15 ) and room-wise AutoCAD-based drawings in editable formats and PDF formats, along with a minimum of two sets of physical (hard copy) drawings, for the complete system clearly highlighting the location of all sprinklers, valves, flow switches grooved fittings and vertical and horizontal pipes i/c all accessories , prepared on a base plan verified against actual site conditions and conforming to a standard legend, title block, drawing and revision numbering system.4. The Agency has to submit police verification record & ID proof of each staff.5. Penalty of will be imposed as per penalty clause for not timely resolving the complaint. If at any stage, it is observed that the performance of agency is not adequate, work will be rescinded, and the agency will be debarred from doing any work for one year in Delhi zone/region. The work will then be carried out at his risk and cost without serving any notice.6.The work to be carried out on holidays/weekends / nights only without disturbing the functioning of office System after taking prior shutdown. Suitable penalty shall be imposed for Non-functioning of equipment due to this work. Decision of Engineer in Charge will be final. The system should be available in good working condition on the next working day. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57929004
AUTHORITY Government Departments
TENDER VALUE 1.59 Crore
LAST DATE 30-10-2026
Authority
Authority Name Bharat Sanchar Nigam Limited
Work Description Tender for Supply, Installation, Testing And Commissioning Of Automatic Fire Sprinkler System And Replacement Of Pipes Of Fire Fighting Wet Riser System In Sanchar Bhawan , New Delhi.
Basic Detail
Tender No 18/NIT/E-TENDER/2026-27/ED-II
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 08 Oct 2026
Submission Date 30 Oct 2026
Open Date 31 Oct 2026
Finance
Tender Value 1.59 Crore
Tender Fee 1180
EMD 3.18 Lakhs
Exemption Available
Document List
5a7b9d5e-854d-4b9c-9890-1817adebb620.html
BOQ_342580.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 08, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Oct 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
html

5a7b9d5e-854d-4b9c-9890-1817adebb620.html

xls

BOQ_342580.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders