Tender For Design, Supply, Erection And Commissioning Of Fire Hydrant System Including Public Addressing System At Beml Palakkad Complex
Tender Value
2.50 Crore
Estimated cost
Bid Submission
26 Oct 2026
15 days left
EMD
5 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Palakkad → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Design, Supply, Erection And Commissioning Of Fire Hydrant System Including Public Addressing System At Beml Palakkad Complex
BOQ
| Sl. No. | Item Description |
| 1 | Design, Supply, Erection and Commissioning of Fire hydrant system at BEML Palakkad complex |
| 2 | Design & Drawing of Fire Hydrant Pipe line Layout. Firm has to design detailed drawing for laying of fire hydrant components. Firm has to take design / drawing approval from BEML before execution of the work, however BEML has given indicative drawing for reference. The cost shall include design charges and As built drawing to be submitted after execution & commissioning. |
| 3 | Supply of following of Class heavy duty GI. Pipes conforming to IS 1239 (Part-1) : 1990 (upto 150 mm dia) and IS 3589:2001 with wall thickness of 6.35 mm (for 200mm and above) to withstand a developing pressure of 10 kg. / sq.cm IS 1239 (Part-1) : 1990Make : TATA /Jindal/ SAIL or Equivalent |
| 4 | 200 mm GI Pipe Class A |
| 5 | 150 mm GI Pipe Class C Heavy |
| 6 | 80 mm GI Pipe Class C Heavy |
| 7 | 6\\" GI Flange class 150 |
| 8 | 3\\" GI Flange class 150 |
| 9 | 6\\" GI 90 deg elbow |
| 10 | 3\\" GI 90 deg elbow |
| 11 | Conc. Reducer 6\\" x 3\\" |
| 12 | GI Tee 6\\" x 3\\" |
| 13 | Supply of double flanged end C.S.\\"Y\\"-type Strainer (The internal Surface of the gate valve and internals should be coated with solvent based epoxy by airless spray method) with S.S.mesh of filtration area equivalent to minimum 1.5 times of inlet area including supply of Companion flanges nuts, bolts, gaskets etc complete in all respectBody: Cast Carbon Steel ASTM – A 216, Gr. WCBEnds: Flanged.Strainers: Stainless Steel AISI :304 Perforated seat.0.70 mm thickness. 6 mm Hole (Basket) & 30 mesh Screen (Net).Filtration Area: Minimum 1.5 times more than Inlet area.Pressure Rating : Class 150.Internal Coating - Solvent based epoxy by airless spray method.IS 907: 1984, PN 16MAKE : AUDCO /KIRLOSKAR / H-SHANKAR / LEADER/ZOLOTTO /INTERVALVE /SAKTHI/ HAWA or Equivalent. |
| 14 | 80 mm dia |
| 15 | Supply of Butterfly Valve,Gate; Design Spec, pressure rating:class 150; Type of end Connection:flanged; Material body:carbon steel; Design spec:API STD 600; Type of Face: Raised face; Type of closure member:wedge; Type of Bore:full; Type of construction:outside screw and yoke; type of bonnet/cover:bolted.IS - 13095: 1991, PN 16) with flanges, nut bolts, gaskets etc. complete as required. Make : AUDCO /KIRLOSKAR / H-SHANKAR / LEADER/ZOLOTTO /INTERVALVE /SAKTHI/ HAWA or Equivalent. |
| 16 | 150 mm dia |
| 17 | 80 mm dia |
| 18 | Supply of Gun metal Single headed Fire Hydrant Single Landing Valve with 80 mm N.B. flanged inlet, brass spindle controlled 63 mm dia female instantaneous outlet type. GM coupling, blank cap (PVC/ABS), chain, twist release type lug & all accessories.IS:5290: 1993 with ISI mark. Including fixing with anchor fastener and flanged tapping from wet riser complete as required.Make : NEWAGE /AAG/ WINCO/ NEWTECH/ PAD MINI or Equivalent |
| 19 | Supply of Fire Hose Cabinet wall mounting type 18 SWG MS thickness (750 mm x 600 mm x 250 mm deep) with double glass door with locking arrangement and painted with two coats of Fire red Enamel paint at outer side of the box and two coats of white enamel paint at inner side of the box with required accessories as per specification and is to accommodate 2 nos. of Fire hose box size 800 x 600 x 250. (NFPA 14 rules).Make : MS / DKP Sheet or Equivalent |
| 20 | Supply of non-percolating rubber reinforced lined Fire Hose pipe of 63 mm dia and 1no x 15 mtrs long. The hose shall be rated for burst pressure of 38kg/sq cm. Hose shall be complete with ISI marked GM/SS male & female coupling IS:903) bound as per specification.Standard- IS : 636: 1988, IS 14933: 2001Make : NEWAGE /AAG/ WINCO/ NEWTECH/ PAD MINI or Equivalent |
| 21 | Supply of 63 mm dia instantaneous pattern Gun metal short branch pipe, 20 mm dia nozzle conforming to IS 903, suitable for inter connection to hose pipe coupling complete as required by the Local Fire Authority.(Standard -IS 2871: 2012) NEWAGE /AAG/ WINCO/ NEWTECH/ PAD MINI or Equivalent |
| 22 | Supply of First Aid Hose Reel equipment conforming to comprising of hose reel drum, swinging type fixing bracket,19 mm high pressure hose, shut off nozzle and Rubber hose of 25 mm bore x 30mtr. Long etc. as per specification complete as requiredIS:884-1985 (Reaffirmed 2005)NEWAGE /AAG/ WINCO/ NEWTECH/ PAD MINI or Equivalent |
| 23 | Supply of forged brass valve, is typically a full-bore, heavy-duty ball valve with female threaded ends, designed for water.Type - Screwed Female Ends, Full BoreBody - Bronze, IS: 318 Gr.LTB2Lever - Carbon SteelStem - BrassShell Test Pressure - 25 Kg/cm²Seat Test Pressure - 16 Kg/cm²Working Temp. - > 60° CIS 13114: 1991 (Reaffirmed 2005), PN 25 Make : AUDCO/KIRLOSKAR/ H-SHANKAR/LEADER/ZOLOTTO/INTERVALVE / SAKHI / HAWA or Equivalent. |
| 24 | 25 mm dia |
| 25 | 15 mm dia |
| 26 | Supply of Galvanised U Clamp, thickness 6 mm, Fastening: Two holes with M8 bolts & nuts, Standard Compliance: IS 2108 / IS 1239, galvanized as per ASTM A153 |
| 27 | 150 mm dia |
| 28 | 80 mm dia |
| 29 | Supply of 150mm dia Cast Iron Four Way Fire Brigade Inlet having inbuilt Gun metal Non- return valve as per Standard - IS: 904: 1983 having 4 nos. of 63 mm dia inlet with blank cap and chain with necessary fittings, flanges, nut, bolts etc. complete as required.IS: 904: 1983Make : NEWAGE /AAG/ WINCO/ NEWTECH/ PAD MINI or Equivalent |
| 30 | Supply & Installation of MS structures consisting of plates, rolled steel joists, channels, angles, rafters, hollow tubes, square pipes, joists, trusses, etc., Also includes rectangular/square hollow steel sections, insert plates in RCC/brickwork, anchor bolts for structure, sleeve pipes, anchor nuts, washers etc., conforming to latest version of SP 6-1 (1964): ISI Handbook. Base structural material shall be as per IS 2062 and then hot dipping GI needs to be done for 80 micron thickness of GI.The above qty is required for items sl.no: 1 to 11 and in addtion to required wherever necessary as directed by Engineer In charge.IS 2062Make : TATA /Nobel/ SAIL/Visak or Equivalent |
| 31 | Anti – Corrosive Tape:- Supply & Installation:The underground steel pipes shall be protected by coating and wrapping. The coating and wrapping shall be done, in general as per Standard IS:10221-1982. *as per specification - wrapping tape spirally, thermo sealing complete (only for the underground pipes covered with Sand and soil).Note: Holiday Testing as to be done IS:10221-1982Make : Rustech / Pypkoe / or equivalent |
| 32 | Supply of 1\\" MS Nipple 300 mm Length, One Side Male Threaded, Mild Steel (MS), conforming to IS 1239IS 1239 (Part-1) : 1990 |
| 33 | Supply of 4\\" Pressure Guage with Glycerine FilledType - Bourdon Type.Dial Size - 100mm.Range - 0 to 14 kg/cm²Accuracy - +/- 1% FSD.Unit of Measurement - Kg/cm²Case - SS 316/304Protection - IP 68.Connection - ½ \\" NPT Male.Make : WIKA/ H GURU/BAUMER or Equivalent |
| 34 | Supply of 6\\" Air Relief Valve. Operating Pressure: typically ranges from 0.5 to 25 bar (PN 10).Temperature Rating: -10°C to 110°C. Body Materials: Cast Iron.Internal Float/Trim: 316 Grade Stainless Steel for high durability and rust resistance.Connection Type: flanged IS14845:2000Make : AUDCO/KIRLOSKAR/ H-SHANKAR/LEADER/ZOLOTTO/INTERVALVE / SAKHI / HAWA or Equivalent. |
| 35 | Supply of CAF Non Metallic GasketsIS 2712Make : CHAMPION/ SEALMAX or Equivalent |
| 36 | Supply of Galvanised Bolt & NutIS 1364-1(2002)Make : UNBRAKO/TVS or Equivalent |
| 37 | Chemical Anchor bolt is a heavy-duty threaded stud that relies on a resin or adhesive mortar (such as epoxy or acrylic) to bond with the substrate (like concrete or masonry) rather than mechanical expansionMake : FISCHER/HILTI or Equivalent |
| 38 | Hydrotesting of Pipeline to be carried out at a pressure of 10 kgf/cm2. Necessary water shall be provided by BEML and Equipments for testing is vendor scope. |
| 39 | Modification of Existing Drain Pipeline: Removal of exisiting rain water gutter wherever necessary and supply & relaying of new rain water gutter including all accessories for fixing to be considered. |
| 40 | Diamond Road cutting up to 100 mm depth, width up to 1m and length up to 10m. Includes excavation of hard soil and soft soil for dismantling and relaying of hydrant pipe at site. |
| 41 | Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m : Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia |
| 42 | Supplying and placing in position STEEL REINFORCEMENT BARS confirming to IS: 1786/1966 Grade-FE: 415 for RCC work including transporting the steel, straightening, cleaning, cutting, binding with 18 SWG black soft annealed binding wire at every intersection, bending to required shapes and lengths as per details at every intersection, supplying and placing proper cover blocks, supports, chairs, overlaps, welding, spacers, etc., at ground levelIS: 1786/1966 |
| 43 | Supply and laying RCC M-25 as per latest version of IS 456; work shall include providing shuttering for formwork, mixing, compacting by vibrators, curing etc., Complete for foundation of structural working platformsIS 456 |
| 44 | Painting of all Pipe lines, channels, joints etc as complete.As per Painting scheme mentioned below -Paint Scheme : Primer-Wash Primer (DFT: 65-75),Intermediate Coat-HB Epoxy MIO (DFT: 65-75) & Finish Coat- Twopack Acrylic Poly-Urethane (PU) (DFT: 40-50/coat) Total Min DFT: 215 microns.Color: Post Office Red of approved qualityMake : BERGER/ SHALIMAR/ ASIAN/NEROLAC/ GROWEL or Equivalent. Please Enable Macros to View BoQ information |
| 45 | Painting of all Pipe lines, channels, joints etc as complete.As per Painting scheme mentioned below -Paint Scheme : Primer-Wash Primer (DFT: 65-75),Intermediate Coat-HB Epoxy MIO (DFT: 65-75) & Finish Coat- Twopack Acrylic Poly-Urethane (PU) (DFT: 40-50/coat) Total Min DFT: 215 microns.Color: Post Office Red of approved qualityMake : BERGER/ SHALIMAR/ ASIAN/NEROLAC/ GROWEL or Equivalent. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 08, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 26, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysOct 26, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender