Educational and Research Institute Government Departments Closing in 0 days TDR #57926929

Tender For Special Repair And Renovation To Be Carried Out In Girls Hostel Priyadarshni, Chanderbagha, Sarijni Naidu And New Girls Hostel (Faculty Residence) At New University C Us, Jammu

Issued by Government Departments · Jammu, Jammu and Kashmir
Tender Value
24.41 Lakhs
Estimated cost
Bid Submission
27 Oct 2026
0 days left
EMD
48427
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jammu → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Special Repair And Renovation To Be Carried Out In Girls Hostel Priyadarshni, Chanderbagha, Sarijni Naidu And New Girls Hostel (Faculty Residence) At New University C Us, Jammu

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 16-Oct-2026 Corrigendum in boq Technical Bid 27-Oct-2026

BOQ

Name of Work:- Special Repair and Renovation to be carried out in Girls Hostel Priyadarshni, Chanderbagha, Sarijni Naidu and New Girls Hostel (Faculty Residence) at New University C us, Jammu
Sl. No. Item Description
1Wiring for light point/fan point/ceiling fan point/exhaust fan point/call bell point with 1.5 Sq. mm FRLS/HFFR PVC insulated, copper conductor cable in surface/recessed medium class PVC conduit, with piano type switch, phenolic, laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq mm. FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. (Wire Make ISI Marked Havells/Anchor /KEI/Polycab, Plaza Conduit Make - ISI Marked Anchor/High Power /AKG) Equivalent make of required specification to be approved by the Engineer In charge) i.Group ‘A’
2Wiring for circuit/sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.(Wire Make ISI Marked Havells/Anchor/KEI/Plaza/polycab Equivalent make of required specification to be approved by the Engineer In charge )i. 2x1.5 +1x1.5 Sq mm
3i. 2x2.5+ 1x2.5 Sq mm
4ii. 2x4 + 1x4 Sq mm
5iii. 4x6 +2x6 Sq mm
6iv. 4x10 +2x6 Sq mm
7Supplying and fixing of following sizes of medium class PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required- ISI Marked Anchor/High Power /AKG)25 mm dia
8Supplying and fixing 5 amp to 32 amps rating, 240/415 volts, 10 KA C curve miniature circuit breaker suitable for inductive load of following poles of in the existing MCB DB complete with connections, testing and commissioning etc. as required.(Make Havells /Anchor/HPL Equivalent make of required specification to be approved by the Engineer In charge) i. Single pole
9Earthing with Copper earth plate 600mm x 600mm x 3mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/coke and salt as required.
10Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
11Supply and fixing of metal Box of following size(nominal size) on the surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required 100mm x 100mm x 60mm deep
12200mm x 125mm x 60mm deep
13Supply & fixing following piano type switch/socket on the existing switch box/cover including connection etc as required. (Make: Anchor/Havells/Philips/Polycap major Equivalent make of required specification to be approved by the Engineer In charge) i.5/6 Amp Switch
14ii.15/16 Amp Switch
15iii.3 pin 5/6 Amp Socket
16iv.6 pin 15/16 Amp Socket
17Supplying and fixing following ways and single pole and neutral,sheet steel,MCB distribution board,240V,on surface/recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolators)( Havells/Anchor /I.A )i. 16 way, Double door
18Supplying and fixing following way, horizontal type three pole and neutral,sheet steel,MCB distribution board,415 V,on surface/recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolators)( Havells/Anchor /I.A Equivalent make of required specification to be approved by the Engineer In charge)i. 6 way(4+18), Double door
19ii. 8 way(4+24), Double door
20Supply & fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (Make Havells/ Anchor /Major Equivalent make of required specification to be approved by the Engineer In charge)
21Supplying and fixing brass batten/Angle holder including connection etc. as required. (Make Havells/ HPL / Anchor / Sanchi Major Equivalent make of required specification to be approved by the Engineer In charge)
22Supplying and fixing 3 pin, 5 A Ceiling Rose on the existing junction box/wooden block including connection etc. as required. (Make Havells/ Anchor / Sanchi Major Equivalent make of required specification to be approved by the Engineer In charge)
23Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Make Anchor /Havells /HPL Equivalent make of required specification to be approved by the Engineer In charge) i. 100 AMP 16kA TP MCCB
24Re-wiring for light point/fan point/call bell point exhaust fan point with 1.5 Sqm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/ PVC conduit including dismantling as required. (Wire Make ISI Marked Havells/Anchor/KEI/Polycab )(Conduit Make - ISI Marked Anchor/High Power /AKG Equivalent make of required specification to be approved by the Engineer In charge) i.Group ‘A’
25Supplying and fixing of following ratings and poles 240/415 volts Isolators in the existing MCB DB complete with connections, testing and commissioning etc. as required (Make Havells /Legrand /Anchor/ C&S/L&T/ Siemen/IA/HPL/Standard Equivalent make of required specification to be approved by the Engineer In charge) a.40 Amp 240 volt Double Pole.
26b.63 Amp 240 volt Double Pole Isolator.
27c.63 Amp 415 volt Four Pole Isolator.
28Supplying and drawing of following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required(Wire Make ISI Marked Havells/HPL/Anchor/KEI/Plaza/Polycab Equivalent make of required specification to be approved by the Engineer In charge) i.1x1.5 sq mm
29ii.3x1.5 sq mm
30iii. 3x2.5 sq mm
31iv.2x6 sq mm
32vi.4x6sq mm
33LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output.LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 50W
34100 watt,230 volts IP 66/IP65.(Street Light)
35Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) ,SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).100 W
369.2 Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
37Non-Schedule Items Supply &Installation of following type of surface mounted/recessed mounted decorative Indoor Linear energy saving , energy efficient LED Lumainiers complete with connection testing and commissioning. Make (Halonix/ Havells/Bajaj/HPL/Compact) Equivalent make of required specification to be approved by the Engineer In charge) 4 feet 18 to 22 watt ,230 volts LED batten type tube light fitting complete .
382 feet 9 to 12 watt ,230 volts LED batten type tube light fitting complete
39Supply, testing and commissioning and Laying of PVC sheathed Aluminum conductor 1100 volts graded PVC AA Armoured/unarmoured XLPE Cable including end termination, crimping, cost of thimbles, nuts bolts, glands, connection, testing and commissioning complete job. (Make: Havells / General/Polycab / Grandley) Equivalent make of required specification to be approved by the Engineer In charge) 2 core 16 sq mm armoured cable
403 ½ core 120 sq mm armoured cable
413 ½ core 35 sq mm armoured cable
42Supply, installation, testing, commissioning of 1200 mm sweep ceiling fans complete with blades BEE 3 star rated energy efficient .(Make: Havells /Anchor/USHA /Crompton) Equivalent make of required specification to be approved by the Engineer In charge)
43Supply /Installation testing and commissioning of 450 mm sweep wall mounted fan including the electronic regulators and connection with testing and commissioning etc complete Job BEE 3 star rated energy efficient. Make: (Anchor /Bajaj /Cromton/ Havells Equivalent make of required specification to be approved by the Engineer In charge )
44Supply, installation, testing, commissioning of heavy duty 300 mm sweep BEE 1 star rated energy efficient exhaust fan. Make: ( Anchor/Havellls/Bajaj/Crompton Equivalent make of required specification to be approved by the Engineer In charge)
45S/F of 32mm dia G.I pipe for flood light bracket including bending to shape, (40x3)mm flat iron clamp and wiring with 1.5 sqmm PVC insulated wire complete wire complete as reqd.
46P/F following rating 230 volts energy saver LED Lamps and LED Tubes 4’ long(Make :Philip /Havells/Bajaj/ Surya/ Crompton/Compact/Halonix Equivalent make of required specification to be approved by the Engineer In charge)i.8 to12 watt LED
47ii.45 to 55 Watt LED
48Providing/fixing following way PVC gang box suitable for following socket and switches. (Havells/Anchor/HPL make Equivalent make of required specification to be approved by the Engineer In charge)i.3 pin 5 Amp socket with switch
49ii.6 pin 15 amp socket with switch
50Supplying and fixing following ways horizontal type MCB Distribution Board 230V on surface/in recess complete interconnections including powder painted etc. as required IP 43 IK09 (But without MCB/SPN.) i.4 way Encloser Havells/Anchor /I.A /HPL/ Equivalent make of required specification to be approved by the Engineer In charge
51Providing/fixing 32 to 40 amp rating , 230 volts SPN MCB of breaking capacity of 10kA in the existing MCB DB or enclose complete with connection testing and commissing complete Job. (Havells/Anchor/HPL make Equivalent make of required specification to be approved by the Engineer In charge)
52Providing/fixing following rating plug tops (Anchor/Sanchi major/HPL make) i.3 pin 5 Amp
53ii.3 pin 15 Amp
54P/F of 3mm thick phenolic laminated sheets of following size.Crown /Hylam. 5’’x5’’
559’’x6’’
5611’’x13’’
573’’ Round
585’’ Round
59Design, manufacture, testing at works & supply, installation, testing & commissioning cubicle panel floor mounted (on base frame) totally enclosed and extensible type . The general construction shall comprise to IS 8623-93. The design shall include all provisions for safety of operating and maintenance personal. IP 42 for indoor and IP54 for outdoor, shall be compartmentalized type having space and arrangements for I/C. cable/bus ducting/incoming switch gears, bus couplers, insulated and properly supported compartmentalized switch gear, outgoing compartmentalized switch gear, bus bar support and terminations, interconnection between bus bars & switch gear with auxiliary bus bars/ insulated conductors/strips etc. (Make Electric Field/ Bharti Engineers/Gupta & Friends/ Jai maa/KED) MAIN OUTDOOR /BUILDING CONTROL PANEL a. INCOMING Space for 1 No. 200 Amp TPN Al. Bus bar of equal cross section for Main Power/Light connectionSpace for 1 No. 150 Amp 4 pole MCCB of 16 KASpace for 1 No. 125 Amp Changeover Switchb. INDICATING PANEL The indicating panel of the incomer shall be provided with the following:i. Ammeter of required range with ASS, CT's.ii.Voltmeter of required range with VSS.c.Space for 1 No. 200 Amp TPN Al. Bus bar of equal cross section for power load/light load. OUTGOING Space for 2 No. 100 Amp 4 pole MCCB of 16 KADimensions3’x4’x1’)
60Supplying and fixing bus bar chamber with 4 strips bus bar of following size, made of the Aluminium, suitable for following capacity complete with all accessories including connections, earthing the body as required. 450mm 100 Amp
61450mm 200 Amp
62Supply and fixing of (75X75)mm press fit type PVC Trunking for drawing the electric wires/Cables. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57926929
AUTHORITY Government Departments
TENDER VALUE 24.41 Lakhs
LAST DATE 27-10-2026
Authority
Authority Name Government University
Work Description Tender for Special Repair And Renovation To Be Carried Out In Girls Hostel Priyadarshni, Chanderbagha, Sarijni Naidu And New Girls Hostel (Faculty Residence) At New University C Us, Jammu
Basic Detail
Tender No enit 248 dated 05-10-2026
Bidding Type Tender
Location
City Jammu
State Jammu and Kashmir
Key Dates
Publish Date 16 Oct 2026
Submission Date 27 Oct 2026
Open Date 01 Jan 0001
Finance
Tender Value 24.41 Lakhs
Tender Fee 1180
EMD 48427
Exemption Not Available
Document List
9897c65c-0690-401a-9419-2355c2f363b5.html
BOQ_1108187.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 27, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Today
Oct 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today

Tender Documents

Download All (ZIP) ↓
html

9897c65c-0690-401a-9419-2355c2f363b5.html

xls

BOQ_1108187.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender