BOQ
| Sl. No. | Item Description |
| 1 | Contract Details |
| 2 | Supply and erecting in true vertical position steel tubuler poles 9 meter long complete with M S base plate , MS pole cap, bolts nuts & screw as specified type 410 SP-31 (9.0 meter long) with and including painting of poles with black bitumenous paint throughout the length internally and outside upto planting depth and remaining portion 2 coats of aluminium paint over a coat of red oxide primer, complete all as specified and directed |
| 3 | Supply and fix loop in and loop out PVC junction box made out of high quality thermoplastic polycarbonate enclosure with IP 65 degree protection, weather proof, corrosion proof, dust proof, insulated and shock proof, fire retardant non toxic material with internally embedded gasket with 10 Amp MCB and 4 nos terminal of size 200x160x98 mm with provn for cable in and out ,incl fixing on the pole with help of clamps made of MS flat iron complete all as specified and as directed of make hensel or equivalent make of sintex/universal |
| 4 | Supply and fixing LED street light fitting 35 Watt/36 watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with electronic driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. |
| 5 | Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with electronic driver , lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. |
| 6 | Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. |
| 7 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of street light fitting/flood light fittings on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. |
| 8 | S & F on pole / wall Nature switch 02 EC with enclosure factory made suitable for 8 KW street light load single phase 240 volts and power contactor rating 40 Ampere with MCB 63 Ampere contactor and terminal block confirming to IEC – 60947 – 4 – 1 / IS – 13947 – 4 – 1 (Sensor alongwith pre-dawn switching off timer, 4 – 8 hours) infrared sensor based switch for intelligent outdoor street light control complete with and including mounting bracket, cable glands, openable doors with lock complete all as specified and directed. |
| 9 | Supply, laying and testing LT cable XLPE 1100 volt grade Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70.0 sq mm 3.5 core |
| 10 | Supply, laying and testing LT cable XLPE 1100 volt grade Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4core |
| 11 | Supply, laying and testing LT cable XLPE 1100 volt grade Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 4core |
| 12 | Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm, 3 core, 1100 Volts grade. |
| 13 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials suitable for 3.5 core, armoured, Al conductor cable of size 70 sqmm,Indoor/Outdoor type, PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required all as specified and directed |
| 14 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials suitable for 4 core, armoured, Al conductor cable of size 25 sqmm,Indoor/Outdoor type, PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required all as specified and directed |
| 15 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials suitable for 4 core, armoured, Al conductor cable of size 16 sqmm,Indoor/Outdoor type, PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required all as specified and directed |
| 16 | Excavation in trenches in hard/dense soil not exc 1.5 mtrs wide and exc 1.5 m in depth for post holes, laying cables and getting out incl jointing bottom surface to the reqd level/slope etc complete all as specified and directed. |
| 17 | Excavation in trenches in hard/dense soil not exc 1.5 mtrs wide and not exc 1.5 m in depth for laying cables and getting out incl jointing bottom surface to the reqd level/slope etc complete all as specified and directed. |
| 18 | Returning filling in incl spreading, leveling, watering and well ramming in layers not exc 25 cm in hard/dense soil all as specified and directed. |
| 19 | Removing excavated material to a distance not exc 15 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point. |
| 20 | M&L for laying of fine river sand, free from sharp material for cable cushioning in trenches all as specified and directed. |
| 21 | Supplying and laying unreinforced precast concrete cable cover Class LV, Type I, flat, size 250mm x 150mm x 40mm standard size for protection of cable completet all as specified & directed |
| 22 | M&L for GI pipe light grade size 80 mm bore with all fittings fixed to pole and laid to floor/ground for mechanical protection of cable all as specified & directed |
| 23 | M&L for GI pipe light grade size 25mm bore with all fittings fixed to pole and laid to floor/ground for mechanical protection of cable all as specified & directed |
| 24 | M & L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation of steel tubular pole incl form work complete all as specified and directed. |
| 25 | M & L for PCC (1: 4:8 ) type D-2 using 40mm graded stone aggregate as in bottom of pit for bed concrete of steel tubular pole incl form work complete all as specified and directed. |
| 26 | M & L for PCC ( 1:2:4) type B-1 using 20mm graded stone aggregate as in coping including all form work complete all as specified and directed. |
| 27 | Supply, fabricating and fixing of sheet metal enclosure for bus bars made of 16 gauge MS sheet outdoor type of suitable size (1000x800x650mm) with three nos 100 Amp rated aluminium busbar and one number 100 Amp aluminium busbar with provn for terminals for connecting at least 4 Nos outgoing cables on bus bar for distribution, on porcelain insulators for neutral link double door type with locking arrangement & holes of required size for cable in and out complete with MS angle iron frame of size 25 x 25 x 5mm with nut/bolts and PCC platform work including painting with two coat of synthetic enamelled paint over one coat of red oxide/ primer complete all as specified and directed at site. |
| 28 | Supply and Fix Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT,440 V, 20x15cm size complete all as specified and directed. |
| 29 | Supply and fixing LT cable/route indicator cast iron of suitable size along LT cable trench including planting in ground with PCC complete all as specified and directed. |
| 30 | M & L for one coat of aluminium shade paint of approved quality including preparation of existing surface of steel tubular poles LT complete including flat iron clamps, bracing , cross arms etc and numbering of poles with white synthetic enamel paint over a circular painted base and strip marking paint up to a height of 5 feet with black & yellow five bands with synthetic paint (strip of 1 feet height each) complete all as specified and directed. |
| 31 | Supply, installation, testing & commissioning of diesel engine silent generator set with acoustic enclosure confirming to latest CPCB norms(CPCB IV+), water cooled capacity 25 KVA ( generator out put should be 25 KVA/20 KW) 50 Hz AC supply, engine as per IS : 10001/ 10002 and alternator as IS : 13364 complete with relay panel and switch gears for automatic starting on main failure (built in AMF Panel) including engine alternator mounted on common base frame and canopy fabricated from steel channel of suitable size, engine and alternator shall be anti vibration mounting pads,sound proof canopy as per latest CPCB norms incl foundation as per manufactures instruction / design complete all as specified directed with and including the following provision :- Refer Particular specification mentioned in NIT /Tender documents of page No 83 and Ser No 32. |
| 32 | Supply, installing, testing and commissioning, factory made and tested LT feeder pillar, outdoor type floor mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and 50x50x6mm thick angle iron base frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both front & rear side opening type, with aprons for cable entry, with double door and locking arrangement and including earth work, and glands of required size for cables. The panel consisting of the following:- (a) Copper bus bar four strips 300 Amps, 415 volts, fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 01 Set.(b) MCCB, 04 Pole, 125 Amps with ultimate breaking capacity 16 KA at 415 volts, with fixed thermal & magnetic settings - 01 No (Incoming) (c) MCCB, 04 Pole,100 Amps with ultimate breaking capacity 10 KA at 415 volts with fixed thermal and magnatic settings - 02 Nos(d) MCB FP 40A -01 Nos(d) Changeover switch 100 A (for DG set backup supply) - 01 Nos(e) Digital Volt meter 0-500 volt with coil and selector switch - 1 No.(f) Digital ammeter 0-500A with CT coil and selector switch- 01 No(g) Indication lamps R,Y,B LED type with 3 Nos – 1 set (h) Space for MCCB 100A - 01 N0(j) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminum strips for MCCB's.(k) Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone.(l) Timer switch -01 |
| 33 | Supply, installing, testing and commissioning, factory made and tested LT feeder pillar, outdoor type floor mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and 50x50x6mm thick angle iron base frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both front & rear side opening type, with aprons for cable entry, with double door and locking arrangement and including earth work, and glands of required size for cables. The panel consisting of the following:- (a) Copper bus bar four strips 200 Amps, 415 volts, fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 01 Set.(b) MCCB, 04 Pole, 100 Amps with ultimate breaking capacity 16 KA at 415 volts, with fixed thermal & magnetic settings - 01 No (Incoming) (c) MCB, 04 Pole, 63 Amps - 03 Nos(d) MCB, SPN, 32 Amps - 02 Nos(d) Digital Volt meter 0-500 volt with coil and selector switch - 1 No.(e) Digital ammeter 0-500A with CT coil and selector switch- 01 No(g) Indication lamps R,Y,B LED type with 3 Nos – 1 set (h) Space for MCCB 100A - 01 N0(j) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminum strips for MCCB's.(k) Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone.(l) Timer switch -01 |
| 34 | M & L for earthing complete with galvanised steel, earth plate electrode 600x600x6mm thick burried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth strip as earthing lead (32x6mm) by means of bolts nuts check nuts and washer of galvanised iron/steel connected to main panel/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate ,watering pipe 20mm dia GI medium grade GI sheet 0.63mm thick funnel , wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150 c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 40mm dia light grade upto 7.5 mtr from electrode and engraving of earth marking on near by structure/painting of earth results etc, complete all as specified indicated on electrical plate No-1 SSR Part_I 2009 Page No-479 and as directed including testing on completion.Note :- (i) Earth lead beyond 7.5 mtr from electrode to earth terminal point/main switch & GI pipe light grade 40mm dia for protection against mechanical damage to lead shall be measured separately. (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost. |
| 35 | M&L for earthing complete with galvanised steel, earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in in electrical plate No 5 on page 19-49 of MES schedule 1991 Part I connected to main switch board /main DBs/ earthing test point Including all necessary excavation and earth work in hard/ dense soil common salt and charcoal dust mixed and packed 150 mm thick all-round the GI earth plate, watering pipe 15 mm dia G I medium grade . GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150C/C both ways and pit/ chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 20mm dia light grade up to 7.5m from complete all as specified ,indicated on electrical plate No 5 and as directed incl testing on completion.NOTE: ( i ) Earth lead beyond 7.5 m from electrode to earth terminal GI pipe light grade 20mm dia for protection against mechanical damage to lead shall be measured separately (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 6 daysCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 6 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender