Tender For Survey, Design& Construction Of Tube Well,Supplying,Carting, Laying & Jointing Of Rising Main &Distribution Network Consisting Of Different Sizes Of Ms Erw &Gi (M) Pipes,Design & Construction Of Clear Water Reservoirs, Over Head Tanks, Pum
Tender Overview
Project Description
Tender for Survey, Design& Construction Of Tube Well,Supplying,Carting, Laying & Jointing Of Rising Main &Distribution Network Consisting Of Different Sizes Of Ms Erw &Gi (M) Pipes,Design & Construction Of Clear Water Reservoirs, Over Head Tanks, Pump Houses, Sump-Cum-Pump Houses, Supply Installation Testing and Commissioning of Pumpingplants, Automation & Scada Works,Providing House Service Connections Along With Supply & Fixing Of Mechanical Water Meters And All Other Appurtenant Works Including Civil & Electro-Mechanical Works Specified In The Boq Of Tender Document Including Supply Of All Materials, Labour, T&P Etc. Complete Required For Proper Completion Of Work Including Commissioning & Trial Run Of Scheme Along With Operation & Maintenance As Well As Revenue Collection Through Departmental Portal For A Period Of 7 Years Of Bhimtal Water Supply Scheme Under World Bank Funded Uewspprogramme.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 08-Oct-2026 | Date Corrigendum | Other | 24-Oct-2026 |
| 2 | 16-Oct-2026 | Date Corrigendum | Date | 30-Oct-2026 |
| 3 | 08-Oct-2026 | Date Corrigendum | Other | 30-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Schedule-1 : Rising Main |
| 2 | Confirmatory survey, design (The contractor has to survey the site, take levels, measure the length of pipe with metallic tape on prescribed alignment and submit the design of the rising main for checking the thickness of pipe before ordering for supply of pipe. On completion of this work, the laid length of pipe will be deemed eligible for supply / payment. The respective amount for quantity of surplus supplied pipes ( which remain laid-unutilized or unlaid ) will be deducted from final bill and such surplus quantity of pipes will be the property of the contractor) supplying, carting, laying & jointing of Rising main of following size, dia & thickness of MS ERW Pipes (YST 210) by welding with approved quality ISI marked electrodes of Adwani or Adore make conforming to ISO 3183 : 2007(E) & IS 816 : 1969 including painting of pipe from inside and outside with anti-corrosive paint in two coats and other appurtenant works such as fixing of air valve, sluice valve, reflux valve at suitable points including making scouring arrangement at suitable locations by fixing tee & gate valve etc complete and also testing & commissioning of laid pipeline including supply of all materials, labour, T&P etc. all complete |
| 3 | 65 mm dia & 4.8 mm thick |
| 4 | 80 mm dia & 4.8 mm thick |
| 5 | 100 mm dia & 4.8 mm thick |
| 6 | 100 mm dia & 5.2 mm thick |
| 7 | 125 mm dia & 4.8 mm thick |
| 8 | 125 mm dia & 5.6 mm thick |
| 9 | 125 mm dia & 7.1 mm thick |
| 10 | 150 mm dia & 4.8 mm thick |
| 11 | 150 mm dia & 6.4 mm thick |
| 12 | Excavation of earth for pipeline in following strata lift upto 1.5 m lead upto 30 m including refilling, watering, ramming of excavated earth into the trenches and removal of surplus earth upto a distance of 60 m from trenches including supply of labour, T & P etc.all complete in all respect as per Uttarakhand Peyjal Nigam and direction of Engineer-in-Charges |
| 13 | Soil mixed with Shingle, Bajri and Boulders |
| 14 | Medium Rock |
| 15 | Supply, fixing & fittings of following size Cast steel Sluice and Scour Valve |
| 16 | 65 mm dia., W.P. = 15 Kg/cm2 |
| 17 | 65 mm dia., W.P. = 30 Kg/cm2 |
| 18 | 65 mm dia., W.P. = 50 Kg/cm2 |
| 19 | 80 mm dia., W.P. = 15 Kg/cm2 |
| 20 | 80 mm dia., W.P. = 30 Kg/cm2 |
| 21 | 80 mm dia., W.P. = 50 Kg/cm2 |
| 22 | 100 mm dia., W.P. = 15 Kg/cm2 |
| 23 | 100 mm dia., W.P. = 30 Kg/cm2 |
| 24 | 100 mm dia., W.P. = 50 Kg/cm2 |
| 25 | 125 mm dia., W.P. = 15 Kg/cm2 |
| 26 | 125 mm dia., W.P. = 30 Kg/cm2 |
| 27 | 125 mm dia., W.P. = 50 Kg/cm2 |
| 28 | 150 mm dia., W.P. = 15 Kg/cm2 |
| 29 | 150 mm dia., W.P. = 30 Kg/cm2 |
| 30 | 150 mm dia., W.P. = 50 Kg/cm2 |
| 31 | Supply, fixing & Fittings of following Cast steel Reflux / Swing Check Valve |
| 32 | 65 mm dia., W.P. = 30 Kg/cm2 |
| 33 | 80 mm dia., W.P. = 30 Kg/cm2 |
| 34 | 100 mm dia., W.P. = 50 Kg/cm2 |
| 35 | 125 mm dia., W.P. = 30 Kg/cm2 |
| 36 | 150 mm dia., W.P. = 50 Kg/cm2 |
| 37 | Supply, fixing & Fittings of following Cast steel Double Ball Air Valve Flanged type |
| 38 | 50 mm dia. , W.P. 15 Kg/cm2 |
| 39 | 50 mm dia. , W.P. 30 Kg/cm2 |
| 40 | 80 mm dia., W.P. 15 Kg/cm2 |
| 41 | 80 mm dia., W.P. 30 Kg/cm2 |
| 42 | 100 mm dia., W.P. 15 Kg/cm2 |
| 43 | 100 mm dia., W.P. 30 Kg/cm2 |
| 44 | Painting of following MSERW Pipes with 2 coats of approved quality. (Anti-Corrosive paint over one coat of Primer) |
| 45 | 65 mm dia |
| 46 | 80 mm dia |
| 47 | 100 mm dia |
| 48 | 125 mm dia |
| 49 | 150 mm dia |
| 50 | Supply of all materials, labour, T & P etc. and Construction of RCC ( 1:1.5:3 ) Sluice Valve / Reflux Valve / Scour Valve/ Air Valve Chamber as per type design complete in all respect as per Uttarakhand Peyjal Nigam specifications and direction of Engineer-in-Charge ( Chamber size :- 1.50 m x 1.50 m x 1.50 m and wall thickness min. 10 cm. ) |
| 51 | Construction of RCC ( 1:2:4 ) Anchor Block with necessary reinforcement along the alignment of Clear Water Rising Main including supply of all materials, labour, T&P etc. complete in all respect as per Uttarakhand Peyjal Nigam specifications and direction of Engineer-in-Charge including cartage of materials. |
| 52 | Size - 0.6m x 0.6m x 0.6m |
| 53 | Size - 0.6m x 0.6m x 0.8m |
| 54 | Size - 0.6m x 0.6m x 0.9m |
| 55 | Size - 0.8m x 0.8m x 0.8m |
| 56 | Size - 0.8m x 0.8m x 1.0m |
| 57 | Size - 0.8m x 0.8m x 1.1m |
| 58 | Size - 1.0m x 1.0m x 1.2m |
| 59 | Size - 1.0m x 1.0m x 1.4m |
| 60 | Size - 1.2m x 1.2m x 1.4m |
| 61 | Size - 1.2m x 1.2m x 1.5m |
| 62 | Size - 1.4m x 1.4m x 1.7m |
| 63 | Instalation of Product Pipe by Auger Boring method including making of entry and exit pits, all related civil works like excavation, shoring/ strutting, etc., shielded excavation through auger boring process, lowering of pipe segments in the jacking pit, laying and jointing of product pipeline through jacking process from the jacking pit and after project completion as per the instructions of the Engineer-in-charge all complete except the cost of the pipe.Upto 300 mm dia (In all type of Soil) Highway Crossing |
| 64 | Schedule-2 : Distribution System |
| 65 | Confirmatory survey, design (The contractor has to survey the site, take levels, measure the length of pipe with metalic tape on prescribed alignment and submit the design of Feeder/ Supply/ Distribution system for checking the thickness of pipe before ordering for supply of pipe. On completion of this work, the laid length of pipe will be deemed eligible forsupply. The respective amount for quantity of surplus supply of pipes (which remained unlaid or unutilized) will be deducted from final bill and surplus quantity of pipes will be the property of contractor) supplying, carting, laying & jointing of Feeder / Supply Main/Distribution main of following size of G.I. (Medium/Heavy) pipe confirming to IS 1239 Part I : 2004 including provision of specials and other appurtenant works such as fixing of flow control valve, air valve, sluice valve etc. at suitable points including making scouring arrangement at suitable locations by fixing tee & gate valve etc. complete and also testing & commissioning of laid pipeline including supply of all materials, labour, T&P etc. complete. |
| 66 | 32 mm dia |
| 67 | 40 mm dia |
| 68 | 50 mm dia |
| 69 | 65 mm dia |
| 70 | 80 mm dia |
| 71 | 100 mm dia |
| 72 | 125 mm dia |
| 73 | 150 mm dia |
| 74 | Supply of pipes and fittings of following grade & sizes (in mm) of MS ERW Pipes (YST 210) Graded Cartage of pipes and fittings from site store to site of works, lowering them into trenches, laying true to alignment and gradient, laying and jointing of pipe line by welding for making up lengths as required for proper completion of work of following sizes (in mm) |
| 75 | 200 mm dia., 4.80 mm thick |
| 76 | Excavation of earth for pipeline in following strata lift upto 1.5 m lead upto 30 m including refilling, watering, ramming of excavated earth into the trenches and removal of surplus earth upto a distance of 60 m from trenches including supply of labour, T & P etc, all complete in all respect as per Uttarakhand Peyjal Nigam and direction of Engineer-in-Charges it is estimated that 100% excavation will be in soil mixed with shingle, bajari and boulders |
| 77 | Soil mixed with Shingle, Bajri and Boulders |
| 78 | Supply, fixing & fittings of the following G.M Gate Valve IS 778 Class -1 including cartage of materials, labour, T & P etc all complete in all respect as per Uttarakhand Peyjal Nigam specifications and direction of Engineer-in-Charge |
| 79 | 32 mm dia |
| 80 | 40 mm dia |
| 81 | Supply, fixing & fittings of the following Sluice valves including cartage of materials, labour, T & P etc all complete in all respect as per Uttarakhand Peyjal Nigam specifications and direction of Engineer-in-Charge |
| 82 | 50 mm dia P.N. 1.0 |
| 83 | 65 mm dia P.N. 1.0 |
| 84 | 80 mm dia P.N. 1.0 |
| 85 | 100 mm dia P.N. 1.0 |
| 86 | 125 mm dia P.N. 1.0 |
| 87 | 150 mm dia P.N. 1.0 |
| 88 | 200 mm dia P.N. 1.0 |
| 89 | Supply, fixing & fittings of the following Air valves (Screwed) including cartage of materials, labour, T & P etc all complete in all respect as per Uttarakhand Peyjal Nigam specifications and direction of Engineer-in-Charge |
| 90 | 20 mm dia |
| 91 | Supplying, fixing & fitting of Fire Hydrant Valve Confirming to IS: 5290 (Flanged) including carting the same upto site of work and fixing the same in water supply lines including cost of valves, specials, labour and T&P complete in all respect as per Uttarakhand Peyjal Nigam specifications and direction of Engineer-in-Charge but excluding the cost of construction of chamber. |
| 92 | Supply of all materials, labour, T & P etc and construction of CR stone masonry Air Valve chamber as per type, design (Size:- 0.6 m x 0.6 m x 0.6 m) all complete in all respect as per Uttarakhand Peyjal Nigam specifications and direction of Engineer-in-Charge |
| 93 | Supply of all materials, labour, T & P etc and construction of RCC ( 1:1.5:3 ) Air Valve chamber as per type, design (Size:- 1.0 m x 1.0 m x 1.0m) all complete in all respect as per Uttarakhand Peyjal Nigam specifications and direction of Engineer-in-Charge |
| 94 | Supply of all materials, labour, T & P etc and construction of RCC ( 1:1.5:3 ) BPT as per type, design all complete in all respect as per Uttarakhand Peyjal Nigam specifications and direction of Engineer-in-Charge |
| 95 | Supply, fixing and fitting of the PRV including cartage of materials, labour, T & P etc all complete in all respect as per Uttarakhand Peyjal Nigam specifications and direction of Engineer-in-Charge |
| 96 | 32 mm dia ( Brass PRV screwed end ) |
| 97 | 40 mm dia ( Brass PRV screwed end ) |
| 98 | 50 mm dia ( Brass PRV screwed end ) |
| 99 | 100 mm dia ( Carbon Steel PRV ) |
| 100 | 125 mm dia ( Carbon Steel PRV ) |
| 101 | 150 mm dia ( Carbon Steel PRV ) |
| 102 | Supply, fixing & fitting of Ultrasonic Water Flow Meter for Bulk pipe lines inline type, flange end with Integral mounted, flow rate & Totaliser display, Battery operated (with five year battery life) communication: UART/ RS485, suitable against antifraud attempts etc. all complete in all respect as per Uttarakhand Peyjal Nigam specifications and direction of Engineer-in-Charge |
| 103 | 65 mm |
| 104 | 100 mm |
| 105 | 125 mm |
| 106 | 150 mm |
| 107 | 200 mm |
| 108 | Instalation of Product Pipe by Auger Boring method including making of entry and exit pits, all related civil works like excavation, horing/ strutting, etc., shielded excavation through auger boring process, lowering of pipe segments in the jacking pit, laying and jointing of product pipeline through jacking process from the jacking pit and after project completion as per the instructions of the Engineer-in-charge all complete except the cost of the pipe. Upto 300 mm dia (In all type of Soil) Highway Crossing |
| 109 | Schedule-3 : House Service Connection |
| 110 | Excavation in Soil mixed with boulders for foundation including lift up to 1.5 m and lead up to 30 m filling, watering and ramming of Excavated the earth into the trenches or into the sides between foundation trenches or into the plinth and removal. |
| 111 | Providing of all materials, Carting from site store to site of work, Laying & Jointing of G.I screwed pipes (including supply of all jointing materials like specials, white lead, hemp and oil etc) in trenches with its cutting, threading and testing of pipe line etc complete. G.I. PIPE CONFORMING TO IS : 1239 (PART-1) Medium Duty (Class 'B') 15 mm dia |
| 112 | Providing and fixing of Clamp saddles should be Non corrosive Engineering Plastic body moulded with Stainless steel threaded metal insert for tapping outlet. Clamp saddles for service connection from water distribution mains shall be of wrap around design, wide skirt and wide straps support, which shall reinforce the pipe while providing excellent stability to the saddle. Clamp Saddles for service connections shall be of fastened strap type with threaded (as per IS:554) (latest version) female outlet of Stainless steel for service connection. The design of the saddle body should be such that, the service connection outlet metal insert shall project out towards pipe side and align with the hole drilled on the pipe to ensure positive locking against rocking or creeping on the pipe, as might be caused by vibration, pressure or excessive external loading. Saddle Seal shall be of virgin rubber SBR Grade 30 / NBR (NSF 61 approved). It shall be of type pressure activated hydro-mechanical design. It shall be contoured gasket to provide a positive initial seal which increases with increase in the line pressure. Saddle straps shall be made of plastic with or without metal reinforcement depending on size and injection molded to prevent galvanic corrosion over the long service life. For 80mm to 350mm dia D.I. Pipe |
| 113 | Supply, fixing & fitting of brass ferrule with C.I. mouth cover including boring and tapping the main : 15 mm nominal bore |
| 114 | Supply, fixing & fitting of PTMT bib cock of approved quality and colour. 15mm nominal bore |
| 115 | Supply, fixing & fitting of S.S. Flow Control Non Return Valve for Avg. Flow 10 lpm. Material of construction to be SS 304. Connection threading IS:554 BSPT, ISO: 7-1. Valve consiste of proprietary design which regulates the designed flow. All machined parts sha |
| 116 | Making ferrule connection in the existing main of G.I, A.C, PVC or any type of pressure mains with saddle piece, service connections, fittings and fixing of G.M. ferrule including tapping the main, but excluding the cost of earth work and cost of all materials. |
| 117 | Supply, fixing & fitting of Plug for House Service Connections |
| 118 | Schedule-4 : Domestic Mechanical Water Meter |
| 119 | DOMESTIC WATER METER DN 15mmP/F Multijet Domestic Mechanical Water Meter Class-B, dry dial, magnetically coupled, temper proof confirming to IS: 779-1994 or ISO: 4064 IP68 in position including all material, albour, T&P etc all complete in all respect as per Uttarakhand Peyjal Nigam specifications and direction of Engineer-in-Charge |
| 120 | Supply, fixing & fitting of Check Valves (Horizontal) before Consumer Meter all complete in all respect as per Uttarakhand Peyjal Nigam specifications and direction of Engineer-in-Charge |
| 121 | Provide necessary T&P and cutting of following nominal dia of G.I. pipes including threading, shaping and finishing the ends. (For Check Valve) |
| 122 | Supply, fixing & fitting of Polycarbonate Box Blue with transparent lid,must have option to seal the box, min three seal option with two iron angle to fix the box. Size- length-255mm , width-210 mm,height- 190 mm |
| 123 | Schedule-5: Storage Reservoir |
| 124 | Design, testing bearing capacity of soil (For CWR 15 KL & above capacity only) and construction of M 30 grade R.C.C. semi-sunk circular Service Reservoir of following capacity and other appurtenant works including supply of necessary scaffolding, shuttering and other accessories alongwith construction of valve chambers, fixing of inlet and outlet pipes, making bye pass arrangement & fixing of lightening conductor & M.S. Manhole Cover, supply and fixing of M.S. Steel Ladder outside and inside the tank and fixing of railing around top dome as per approved design of R.C.C. tank in latest IS codes including painting with plastic emulsion paint and also connection with the exsiting network alongwith carting of all materials including supply & fixing of Bucket Type Chlorinator 25 L capacity on top of reservoir including fixing of Bulk water meters, water level indicator supply of all materials, labour, T&P etc. complete in all respect as per Uttarakhand Peyjal Nigam specifications and direction of Engineer-in-Charge |
| 125 | 15 KL |
| 126 | 45 KL |
| 127 | 60 KL |
| 128 | 100 KL |
| 129 | 150 KL |
| 130 | 200 KL |
| 131 | 250 KL |
| 132 | Supply, fixing and installation of Bucket Type Chlorinator of 25 L Capacity on the top of Service Reservoirs complete in all respect as per Uttarakhand Peyjal Nigam specifications and direction of Engineer-in-Charge |
| 133 | Schedule-6 : Pump House |
| 134 | Design, testing bearing capacity of soil, and construction of Pump House / H.T. Panel Room of specified size in RCC frame structure with brick masonry work, including RCC flat roof, painting with deluxe multi-surface paint and all other appurtenant works. The work includes construction of foundations for pumps, cable trench from transformer to pump house, internal electrification, doors, windows, and ventilation, all as per approved designs and drawings. Scope includes supply of all materials, labour, T&P, carriage of materials, design and erection of required gantry structure with specified load capacity, duty room with toilet, and bathroom facility, complete in all respect as per Uttarakhand Peyjal Nigam specifications and direction of Engineer-in-Charge |
| 135 | Size - 4.0 M x 3.0 M x 3.50 M |
| 136 | Size - 6.0 M x 5.0 M x 4.50 M |
| 137 | Size - 9.0 M x 6.0 M x 4.50 M |
| 138 | Schedule-7 : Staff Quarter |
| 139 | Supply of all materials, labour, T&P, etc. and construction of GRC Building / Staff Quarter including Toilet block (Type-1) for Pump Operators and Chaukidar, as per approved type design and drawings. The scope includes construction of foundation, internal electrification, doors, windows, and ventilation, painting with deluxe multi-surface paint, plumbing/sanitary fittings, and all other appurtenant works complete in all respects, as per approved designs, drawings, and directions of the Engineer-in-Charge. |
| 140 | Schedule-8 : Miscellaneous Work |
| 141 | Provide all materials, labour, T & P for Construction of Half brick Boundary Wall 1.5 m high with 23cm x 23 cm brick masonry pillar every 1.50 meter and 30 cm below ground level , with plaster in 1:4 cement and sand mortar all over and three or more coats of acrylic smooth exterior paint complete in all respect as per Uttarakhand Peyjal Nigam specifications and direction of Engineer-in-Charge |
| 142 | Provision of Barbed Wire Fencing through angle iron posts of size 50x50x6mm and height of post 1.8m weight of wire not less than 9.38 kg per 100m and spacing of row 15 cm c/c barbed wire shall be cross diagonaly of post around the water works site on the top of Boundary Wall complete in all respect as per Uttarakhand Peyjal Nigam specifications and direction of Engineer-in-Charge |
| 143 | Provide all materials, labour, T & P for Construction of 3.60 m wide MS Iron Gate (weight not less than 250 kg.) with two nos. 2- brick thick brick masonry Pillars 2.00 m high and 30 cm below ground level in 2 and half brick masonry over 10 cm thick PCC 1:4:8 ( 1 cement, 4 sand and 8 stone aggregate). Pillars to plastered all over in 1:4 Cement and Sand mortar , complete with two or more coats of synthetic enamelled paint over a coat of steel primer on steel work and acrylic smooth exterior paint for pillars. |
| 144 | Construction of 3m wide Approach Road from motor road to pump House including with protection /retaining wall including all materials , labour T & P requred for proper movements of vehicles etc complete. |
| 145 | Brick work with common burnt clay FPS ( non modula ) bricks of class designation 7.5 in foundation and plinth in [ Cement mortar 1:4 ( 1 Cement : 4 Coarse sand ) ] |
| 146 | Brick work with common burnt clay FPS ( non modula ) bricks of class designation 7.5 in Superstructure above plinth level up to floor V level in All shapes and sizes in : [ Cement mortar 1:6 ( 1 Cement : 1 Coarse sand ) ] |
| 147 | Steel reinforcement for RCC work including straightening, cutting, bending, placing, in position and binding all complete upto plinth level. ( Hot rolled deformed bars ) |
| 148 | 12 mm thick cement plaster 1:6 (1cement : 6 coarse sand) |
| 149 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All works up to plinth level 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ) |
| 150 | Concrete with cement, coarse sand and 40 mm gauge stone ballast in proportion 1:4:8 ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size ) in foundations and floors including supply of all material, labour and T&P etc. required or proper completion of the work. as per drawings and technical specifications |
| 151 | Random Rubble Stone Masonry laid dry including supply of all materials, labour, T&P etc. complete in all respect as per Uttarakhand Peyjal Nigam specifications and direction of Engineer-in-Charge |
| 152 | Schedule-9 : Protection Work |
| 153 | Excavation in all types of strata for foundation works, using manual T&P such as pickaxes, sabbals, crowbars, or by controlled blasting where required, with a lift up to 1.5 m and lead up to 30 m. Scope includes refilling, watering, and ramming of excavated earth around foundations, and removal with disposal of surplus excavated earth up to a distance of 60 m, including dressing/levelling for site development. Complete in all respects including supply of all materials, labour, T&P, cartage, and directions of the Engineer-in-Charge. |
| 154 | Concrete with cement, coarse sand and 40 mm gauge stone ballast in proportion 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size ) in foundations and floors including supply of all material, labour and T&P etc. required or proper completion of the work. as per drawings and technical specifications |
| 155 | RR Stone Masonry 1:6 including supply of all materials, labour, T&P etc. complete in all respect as per Uttarakhand Peyjal Nigam specifications and direction of Engineer-in-Charge |
| 156 | Schedule-10 : Road Cutting & Reinstatement charges |
| 157 | Dismantling of following existing road pavement for laying different sizes of pipes, stacking the serviceable materials and disposal of waste materials upto a distance of 30 m including supply of materials, labour, T&P etc. complete |
| 158 | Bituminous road (Single Layer) |
| 159 | CC Road |
| 160 | Construction charge for road cutting and restoration of CC road pavement (dismantled during pipe laying) including disposal of debris upto 60 m lead; constructing un-reinforced Cement Concrete pavement (M-30 grade using 43 grade cement conforming to IS:383, max aggregate size 25 mm) as per design over prepared sub-base including 100 mm thick PCC 1:4:8 base; mixing using concrete mixer (min 0.2 cum) with weigh batcher, laying in approved side formwork (steel channel, wedges, plates), 125 micron polythene film, compaction with needle/plate vibrators, continuous finishing, lines/grades alignment, 14 days curing/curing compound, and supply of all materials, labour, T&P complete as per drawings and technical specifications and direction of Engineer-in-Charge |
| 161 | Schedule-11 : GIS mapping of complete water supply scheme |
| 162 | GIS mapping of complete water supply scheme of following works using high-precision DGPS/GPS survey; capturing exact spatial coordinates and asset attributes; submission of complete GIS layers/Shapefiles/KML and printable Geo-referenced maps, including all software, equipment, data processing, and site verification complete as per direction of Engineer-in-Charge. |
| 163 | Rising Mian including Intake works, PH, TW etc. complete as per direction of Engineer-in-Charge. |
| 164 | Distribution Network including Service Reservoir, Valves etc complete as per direction of Engineer-in-Charge. |
| 165 | House Service Connections etc complete as per direction of Engineer-in-Charge. |
| 166 | Schedule-12 :Source sustainability work |
| 167 | Construction of Dry Stone Check Dam / Contour Trenches / Chal Khal / Water Harvesting Pit / Random Rubble (R.R.) Stone Masonry Check Dam / Wire Crate (Gabion) Check Dam as per approved design including excavation, dressing of bed/slopes, backfilling, supply of all materials, labour, T&P complete in all respects as per Uttarakhand Peyjal Nigam specifications and directions of Engineer-in-Charge. |
| 168 | Excavation of earth mixed with boulders etc requiring use of specials T&P such as pick axe pabbels etc.for foundation including lift up to 1.50 m and lead upto 30 filling watering and ramming of excavated earth into trenches or into plinth and disposal of surplus earth upto a distance of 60 m from the foundation trenches. |
| 169 | Soil mix boulders |
| 170 | Medium rock |
| 171 | Provide and lay P.C.C 1:4:8 with cement, local sand and 40 mm gauge stone ballast including supply of all material labour T&P required for proper completion of the work in foundation |
| 172 | RR Stone Masonry 1:6 including supply of all materials, labour, T&P etc. complete in all respect as per Uttarakhand Peyjal Nigam specifications and direction of Engineer-in-Charge |
| 173 | Concrete with cement, coarse sand and 40 mm gauge stone ballast in proportion 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size ) in foundations and floors including supply of all material, labour and T&P etc. required or proper completion of the work. as per drawings and technical specifications |
| 174 | Wire crate check 3.0 mx1.5 mx 1.5 m |
| 175 | Electrical and Mechanical Works |
| 176 | Construction of Trial Bore for proposed tubewell (4Nos.). |
| 177 | Transportation of suitable truck mounted ODEX/DTH drilling Rig Machine along with all necessary accessories i.e. Compressor, O.P. Unit and other relevant T & P upto site of work and back after completion of work complete. |
| 178 | Drilling of bores as per IS 2800-1979 using ODEX 115 (Tubex) attachment required drilling in alluvial, boulder, pebbles, gravel, rocky stone, sticky clay etc. including cost of attachment consumable stores, bits, water POL etc. complete with system of simultaneous lowering of 125 mm nominal bore 5.4 mm thick MSERW fin cut casing pipe which will be welded together etc. Complete in all respect as per direction of Engineer-In-charge. |
| 179 | 125 mm dia DTH Bore |
| 180 | Flashing of Tube Well by air compressor. |
| 181 | Development of bore by O.P. Unit through diesel engine driven D.G. set including the cost of installation, lowering of O.P. unit, Coloumn Pipe and dismantling of O.P. Unit, M.S. Pipe after completion of works. |
| 182 | Lifting of 125 mm dia MSERW Casing pipe from the ODEX drilled bore with the help of suitable tools of ODEX/DTH drill machine after measuring discharge by O.P. Unit. |
| 183 | Site clearance after completion of work. |
| 184 | Site devlopment (approchable way, rock cutting & plaining of site as per machine requirement). |
| 185 | Casing shoe |
| 186 | Bit tube for ODEX- 115 |
| 187 | Construction of 200mm dia, 120Mt.deep Tubewell (9 Nos.) |
| 188 | Transportation of suitable truck mounted ODEX/DTH drilling Rig Machine with compressor, O.P. Unit and other T&P, Tripod, Diesel driven generator set and related accessories up to site and back upto destination after completion of work. |
| 189 | Drilling of bores as per IS 2800-1970 using odex 236 (tubex) attachment required drilling complete in all respect with sinking of following size M.S.E.R.W. fincut casing plain/ Perforated pipe.(i) 200mm dia M.S.E.R.W. fincut pipe from G.L. 120Mt.BGL. |
| 190 | Flushing of tubewell by 350 PSI & 1100 CFM air compressor including transpotation, installation and dismantling of compressor at site after completion of work with all T&P etc. |
| 191 | 200 mm dia DTH bore. |
| 192 | Dismantling of Rig machine after completion of work. Fitting of well cap. |
| 193 | Supply of 200mm dia M.S.E.R.W. fincut pipe 7.1mm thick plain pipe as per IS 1239/ 4270 with tolerance as per manufacturer norms in the normal length of 3.00m each. |
| 194 | Supply of 200mm dia M.S.E.R.W. fincut pipe 7.1mm thick Perforated pipe as per IS 1239/ 4270 with tolerance as per manufacturer norms in the normal length of 3.00m each. |
| 195 | Supply and fixing of suitable casing shoe of EN-24 steel as per odex attachment of 200mm dia. |
| 196 | Supply of 200mm dia M.S. well cap. |
| 197 | Development by O.P. Unit |
| 198 | Transportation instalation and lowering of submersible OP Unit with 80 mm dia ms column pipe with accessories up to 80mtr or as per required depth complete with power wiring and dismentling after development with site clearance |
| 199 | Development of tubewell by submersible O.P. unit of 500 LPM, 110mt. head to get required sand free discharge of (300-500) LPM by diesel driven generator set (Including labour diesel, lubricants etc.) |
| 200 | Chemical/ Bacteriological test of water sample |
| 201 | Hydro-geological Survey of site |
| 202 | Construction of 250mm dia, 60 Mt.deep Tubewell (2 Nos.) |
| 203 | Transportation of suitable truck mounted ODEX/DTH drilling Rig Machine with compressor, O.P. Unit and other T&P, Tripod, Diesel driven generator set and related accessories up to site and back upto destination after completion of work. |
| 204 | Drilling of bores as per IS 2800-1970 using odex 236 (tubex) attachment required drilling complete in all respect with sinking of following size M.S.E.R.W. fincut casing plain/ Perforated pipe.(i) 250mm dia M.S.E.R.W. fincut pipe from G.L. 60Mt.BGL. |
| 205 | Flushing of tubewell by 350 PSI & 1100 CFM air compressor including transpotation, installation and dismantling of compressor at site after completion of work with all T&P etc. |
| 206 | 300 mm dia DTH bore. |
| 207 | Dismantling of Rig machine after completion of work. Fitting of well cap. |
| 208 | Supply of 250mm dia M.S.E.R.W. fincut pipe 7.1mm thick plain pipe as per IS 1239/ 4270 with tolerance as per manufacturer norms in the normal length of 3.00m each. |
| 209 | Supply of 250mm dia M.S.E.R.W. fincut pipe 7.1mm thick Perforated pipe as per IS 1239/ 4270 with tolerance as per manufacturer norms in the normal length of 3.00m each. |
| 210 | Supply and fixing of suitable casing shoe of EN-24 steel as per odex attachment of 250mm dia. |
| 211 | Supply of 250mm dia M.S. well cap. |
| 212 | Development by O.P. Unit |
| 213 | Transportation instalation and lowering of submersible OP Unit with 80 mm dia ms column pipe with accessories up to 80mtr or as per required depth complete with power wiring and dismentling after development with site clearance |
| 214 | Development of tubewell by submersible O.P. unit of 750/1000 LPM, 45 mt. head to get required sand free discharge of (600-750) LPM by diesel driven generator set (Including labour diesel, lubricants etc.) |
| 215 | Chemical/ Bacteriological test of water sample |
| 216 | Hydro-geological Survey of site |
| 217 | S.I.T.C. of Submersible Pumping Plant with Accessories for Ex. TW Nisola-1 To Prop Sump Naldamayanti Lake |
| 218 | Supply of Submersible pump and motor set: 375 L.P.M. discharge at 110 mts. NEH. |
| 219 | Supply of Submersible pump and motor set: 375 L.P.M. discharge at 110 mts. NEH. as spare. |
| 220 | Providing, Installation and commissioning of Power coated and CNC fabricated electric control panel upto 20 HP submersible pump set, 14 SWCG CRCA sheet thickness of energy saving variable frequency starter of 20 HP heavy duty which will operate submersible pump coomprises of which includes F-MCCB AMP, Spreader links, rotary handles, red, yellow, blue and Amber indicators, current transformers (CT's), multi function meter which will indicate PF, THD, current, voltage, KWH and KVar etc. MCB's, voltage protections devices, surge protection devices which will handle type I and type 2 surges, control transformers to provide proper phase and neutral to the control devices in panel, selector switches, input choke for 20 HP control contractors and main contactors at the output of VFD, terminal blocks, power and control wiring to the entire. |
| 221 | Automatic Power Factor Control panel (APFC) upto 10KVAR with monitoring power factor of electrical system using sensors and micro processores |
| 222 | Supply of of 10 sq.mm. 3 core Copper conductor P.V.C. insulated submersible cable |
| 223 | Supply of Earthing materials as per specification and site Requirment |
| 224 | Supply of Main piping and valves as per specification and site Requirment |
| 225 | SITC of AC based diaphram operated dual solenoid control valve sluice valve (2 Nos) for flow / presssure / level controlling with controller / RTU PN 10/16, Bonnet- DI (GGG-50), tubing SS304, capable to transmit / communicate data to MIS as well as local control room server of 80 mm dia delivery pipeline. |
| 226 | Supply of 40KVA automatic voltage regulator (compact) servo controlled stabilizer with accessories as per specification and site Requirement |
| 227 | Supply of chain pulley 3.0 tonne capacity with 4.5mt.lift . |
| 228 | Supply of Gauges as per specification |
| 229 | Supply of Rubber Insulation sheet 1mt. x 2mt.x 0.025 mtr. |
| 230 | Supply of 100 Amp. TPN Main Switch |
| 231 | Installation, commissioning and Testing of all pumping plant & Accessoriees complete |
| 232 | Painting of entire installation with 2 coats of super enamel paint as per direction of Engineer-In-Charge of works. |
| 233 | Fire exhtenguisher (6Kg) |
| 234 | Tools and Spanners – |
| 235 | Autophase reseval Unit (APR) Panel as per specifications. |
| 236 | Internal & external Electrification of Pump house |
| 237 | Intelligent GSM/Web/PLC based Mini Remote Terminal Units/PLC with analog and digital parameters and features as specified mini T.W. and transmit data on GSM backbone. GSM based wireless Communication system capable to transfer and gather data from remote sites to master Control Stations (Voltage, Current, Power factor, Pumping running Hour etc.) with 6 Amp. Automatic Voltage stabilizer including high and low cut and isolation transformer including Erection, testing and commissioining and modification of starter with AC and DC relays and necessary wiring complete in all respect. |
| 238 | Data commmunication gateway devices for data acquisition and communication to IOT based cloud server centralized system with stand protocol using wi-fi / GPRS ethernet for atteast 02 months data backup with all accessories. |
| 239 | Over voltage & under voltage trip protection (350 V-450 V) |
| 240 | IOT based intelligent Pressure transmitter capable to communicate / transmit data to MIS as well as local control room servor for tubewell |
| 241 | IOT based Electro magnetic flow meter of 80 mm size capable to communicate / transmit data to MIS as well as local control room servor for tubewell. |
| 242 | SITC of depth sensor for tubewell (upto 100 mt range) with non vented pressure sensor, sensor cable and necessary accessories complete as per technical specification hydrostatic level transmitter should be capable of transmitting data to SCADA system and portal. |
| 243 | Supply, installation, testing and commissioning of online Chlorine, pH and TDS measuring unit for water supply system, suitable for continuous monitoring of treated/raw water quality, complete with industrial-grade pH sensor and TDS sensor with necessary flow cell / immersion arrangement, automatic temperature compensation, digital transmitter and display unit.The system shall be operable on AC power supply as well as solar power with provision of solar panel, charge controllerand battery backup, ensuring uninterrupted operation. The unit shall be complete with control and communication module capable of transmitting real-time pH and TDS data, alarms and system status to the Monitoring & Control System (MCS) / SCADA through suitable communication protocol (RS-485 / GSM / NB-IoT / Ethernet as applicable). The system shall include enclosure of minimum IP-65 protection, mounting structure, signal and power cables, cable glands, earthing, software configuration, calibration, testing, commissioning and integration with MCS, complete in all respects as per tender document specifications. |
| 244 | CCTV camera with 2 MP, IP dome CCTV colour night vision, Dline 2 port POE switch full Giga, D link connector PVC box, complete wireless communication setup and 128 GB memory card. |
| 245 | UPS of suitable capacity for control supply of automation |
| 246 | SITC of ultrasonic type level transmitter for GLSR complete. |
| 247 | Signal cabling between RTU/PLC and field instruments including screened/unscreened & control copper cable, etc complete in all respect |
| 248 | S.I.T.C. of Submersible Pumping Plant with Accessories for Prop Tw Sattal To Prop Sump Sattal |
| 249 | Supply of Submersible pump and motor set: 400 L.P.M. discharge at 110 mts. NEH. |
| 250 | Supply of Submersible pump and motor set: 400 L.P.M. discharge at 110 mts. NEH. as spare. |
| 251 | Providing, Installation and commissioning of Power coated and CNC fabricated electric control panel upto 20 HP submersible pump set, 14 SWCG CRCA sheet thickness of energy saving variable frequency starter of 20 HP heavy duty which will operate submersible pump coomprises of which includes F-MCCB AMP, Spreader links, rotary handles, red, yellow, blue and Amber indicators, current transformers (CT's), multi function meter which will indicate PF, THD, current, voltage, KWH and KVar etc. MCB's, voltage protections devices, surge protection devices which will handle type I and type 2 surges, control transformers to provide proper phase and neutral to the control devices in panel, selector switches, input choke for 20 HP control contractors and main contactors at the output of VFD, terminal blocks, power and control wiring to the entire. |
| 252 | Automatic Power Factor Control panel (APFC) upto 10KVAR with monitoring power factor of electrical system using sensors and micro processores |
| 253 | Supply of of 10 sq.mm. 3 core Copper conductor P.V.C. insulated submersible cable |
| 254 | Supply of Earthing materials as per specification and site Requirment |
| 255 | Supply of Main piping and valves as per specification and site Requirment |
| 256 | SITC of AC based diaphram operated dual solenoid control valve sluice valve (2 Nos) for flow / presssure / level controlling with controller / RTU PN 10/16, Bonnet- DI (GGG-50), tubing SS304, capable to transmit / communicate data to MIS as well as local control room server of 80 mm dia delivery pipeline. |
| 257 | Supply of 40KVA automatic voltage regulator (compact) servo controlled stabilizer with accessories as per specification and site Requirement |
| 258 | Supply of chain pulley 3.0 tonne capacity with 4.5mt.lift . |
| 259 | Supply of Gauges as per specification |
| 260 | Supply of Rubber Insulation sheet 1mt. x 2mt.x 0.025 mtr. |
| 261 | Supply of 100 Amp. TPN Main Switch |
| 262 | Installation, commissioning and Testing of all pumping plant & Accessoriees complete |
| 263 | Painting of entire installation with 2 coats of super enamel paint as per direction of Engineer-In-Charge of works. |
| 264 | Fire exhtenguisher (6Kg) |
| 265 | Tools and Spanners – |
| 266 | Autophase reseval Unit (APR) Panel as per specifications. |
| 267 | Internal & external Electrification of Pump house |
| 268 | Intelligent GSM/Web/PLC based Mini Remote Terminal Units/PLC with analog and digital parameters and features as specified mini T.W. and transmit data on GSM backbone. GSM based wireless Communication system capable to transfer and gather data from remote sites to master Control Stations (Voltage, Current, Power factor, Pumping running Hour etc.) with 6 Amp. Automatic Voltage stabilizer including high and low cut and isolation transformer including Erection, testing and commissioining and modification of starter with AC and DC relays and necessary wiring complete in all respect. |
| 269 | Data commmunication gatway devices for data acquisition and communication to IOT based cloud server centralized system with stand protocol using wi-fi / GPRS ethernet for atteast 02 months data backup with all accessories. |
| 270 | Over voltage & under voltage trip protection (350 V-450 V) |
| 271 | IOT based intelligent Pressure transmitter capable to communicate / transmit data to MIS as well as local control room servor for tubewell |
| 272 | IOT based Electro magnetic flow meter of 80 mm size capable to communicate / transmit data to MIS as well as local control room servor for tubewell. |
| 273 | SITC of depth sensor for tubewell (upto 120 mt range) with non vented pressure sensor, sensor cable and necessary accessories complete as per technical specification hydrostatic level transmitter should be capable of transmitting data to SCADA system and portal. |
| 274 | Supply, installation, testing and commissioning of online Chlorine, pH and TDS measuring unit for water supply system, suitable for continuous monitoring of treated/raw water quality, complete with industrial-grade pH sensor and TDS sensor with necessary flow cell / immersion arrangement, automatic temperature compensation, digital transmitter and display unit.The system shall be operable on AC power supply as well as solar power with provision of solar panel, charge controllerand battery backup, ensuring uninterrupted operation. The unit shall be complete with control and communication module capable of transmitting real-time pH and TDS data, alarms and system status to the Monitoring & Control System (MCS) / SCADA through suitable communication protocol (RS-485 / GSM / NB-IoT / Ethernet as applicable). The system shall include enclosure of minimum IP-65 protection, mounting structure, signal and power cables, cable glands, earthing, software configuration, calibration, testing, commissioning and integration with MCS, complete in all respects as per tender document specifications. |
| 275 | CCTV camera with 2 MP, IP dome CCTV colour night vision, Dline 2 port POE switch full Giga, D link connector PVC box, complete wireless communication setup and 128 GB memory card. |
| 276 | UPS of suitable capacity for control supply of automation |
| 277 | SITC of ultrasonic type level transmitter for GLSR complete. |
| 278 | Signal cabling between RTU/PLC and field instruments including screened/unscreened & control copper cable, etc complete in all respect |
| 279 | S.I.T.C. of Submersible Pumping Plant with Accessories for Ex TW Block Office To Prop Sump Block Office |
| 280 | Supply of Submersible pump and motor set: 600 L.P.M. discharge at 75 mts. NEH. |
| 281 | Supply of Submersible pump and motor set: 600 L.P.M. discharge at 75 mts. NEH. as spare. |
| 282 | Providing, Installation and commissioning of Power coated and CNC fabricated electric control panel upto 20 HP submersible pump set, 14 SWCG CRCA sheet thickness of energy saving variable frequency starter of 20 HP heavy duty which will operate submersible pump coomprises of which includes F-MCCB AMP, Spreader links, rotary handles, red, yellow, blue and Amber indicators, current transformers (CT's), multi function meter which will indicate PF, THD, current, voltage, KWH and KVar etc. MCB's, voltage protections devices, surge protection devices which will handle type I and type 2 surges, control transformers to provide proper phase and neutral to the control devices in panel, selector switches, input choke for 20 HP control contractors and main contactors at the output of VFD, terminal blocks, power and control wiring to the entire. |
| 283 | Automatic Power Factor Control panel (APFC) upto 10KVAR with monitoring power factor of electrical system using sensors and micro processores |
| 284 | Supply of of 10 sq.mm. 3 core Copper conductor P.V.C. insulated submersible cable |
| 285 | Supply of Earthing materials as per specification and site Requirment |
| 286 | Supply of Main piping and valves as per specification and site Requirment |
| 287 | SITC of AC based diaphram operated dual solenoid control valve sluice valve (2 Nos) for flow / presssure / level controlling with controller / RTU PN 10/16, Bonnet- DI (GGG-50), tubing SS304, capable to transmit / communicate data to MIS as well as local control room server of 80 mm dia delivery pipeline. |
| 288 | Supply of 40KVA automatic voltage regulator (compact) servo controlled stabilizer with accessories as per specification and site Requirement |
| 289 | Supply of chain pulley 3.0 tonne capacity with 4.5mt.lift . |
| 290 | Supply of Gauges as per specification |
| 291 | Supply of Rubber Insulation sheet 1mt. x 2mt.x 0.025 mtr. |
| 292 | Supply of 100 Amp. TPN Main Switch |
| 293 | Installation, commissioning and Testing of all pumping plant & Accessoriees complete |
| 294 | Painting of entire installation with 2 coats of super enamel paint as per direction of Engineer-In-Charge of works. |
| 295 | Fire exhtenguisher (6Kg) |
| 296 | Tools and Spanners – |
| 297 | Autophase reseval Unit (APR) Panel as per specifications. |
| 298 | Internal & external Electrification of Pump house |
| 299 | Intelligent GSM/Web/PLC based Mini Remote Terminal Units/PLC with analog and digital parameters and features as specified mini T.W. and transmit data on GSM backbone. GSM based wireless Communication system capable to transfer and gather data from remote sites to master Control Stations (Voltage, Current, Power factor, Pumping running Hour etc.) with 6 Amp. Automatic Voltage stabilizer including high and low cut and isolation transformer including Erection, testing and commissioining and modification of starter with AC and DC relays and necessary wiring complete in all respect. |
| 300 | Data commmunication gatway devices for data acquisition and communication to IOT based cloud server centralized system with stand protocol using wi-fi / GPRS ethernet for atteast 02 months data backup with all accessories. |
| 301 | Over voltage & under voltage trip protection (350 V-450 V) |
| 302 | IOT based intelligent Pressure transmitter capable to communicate / transmit data to MIS as well as local control room servor for tubewell |
| 303 | IOT based Electro magnetic flow meter of 80 mm size capable to communicate / transmit data to MIS as well as local control room servor for tubewell. |
| 304 | SITC of depth sensor for tubewell (upto 100 mt range) with non vented pressure sensor, sensor cable and necessary accessories complete as per technical specification hydrostatic level transmitter should be capable of transmitting data to SCADA system and portal. |
| 305 | Supply, installation, testing and commissioning of online Chlorine, pH and TDS measuring unit for water supply system, suitable for continuous monitoring of treated/raw water quality, complete with industrial-grade pH sensor and TDS sensor with necessary flow cell / immersion arrangement, automatic temperature compensation, digital transmitter and display unit.The system shall be operable on AC power supply as well as solar power with provision of solar panel, charge controllerand battery backup, ensuring uninterrupted operation. The unit shall be complete with control and communication module capable of transmitting real-time pH and TDS data, alarms and system status to the Monitoring & Control System (MCS) / SCADA through suitable communication protocol (RS-485 / GSM / NB-IoT / Ethernet as applicable). The system shall include enclosure of minimum IP-65 protection, mounting structure, signal and power cables, cable glands, earthing, software configuration, calibration, testing, commissioning and integration with MCS, complete in all respects as per tender document specifications. |
| 306 | CCTV camera with 2 MP, IP dome CCTV colour night vision, Dline 2 port POE switch full Giga, D link connector PVC box, complete wireless communication setup and 128 GB memory card. |
| 307 | UPS of suitable capacity for control supply of automation |
| 308 | SITC of ultrasonic type level transmitter for GLSR complete. |
| 309 | Signal cabling between RTU/PLC and field instruments including screened/unscreened & control copper cable, etc complete in all respect |
| 310 | S.I.T.C. of Submersible Pumping Plant with Accessories for Prop TW Near Youwa Kalyan To Prop Sump Block Office |
| 311 | Supply of Submersible pump and motor set: 500 L.P.M. discharge at 80 mts. NEH. |
| 312 | Supply of Submersible pump and motor set: 500 L.P.M. discharge at 80 mts. NEH. as spare. |
| 313 | Providing, Installation and commissioning of Power coated and CNC fabricated electric control panel upto 20 HP submersible pump set, 14 SWCG CRCA sheet thickness of energy saving variable frequency starter of 20 HP heavy duty which will operate submersible pump coomprises of which includes F-MCCB AMP, Spreader links, rotary handles, red, yellow, blue and Amber indicators, current transformers (CT's), multi function meter which will indicate PF, THD, current, voltage, KWH and KVar etc. MCB's, voltage protections devices, surge protection devices which will handle type I and type 2 surges, control transformers to provide proper phase and neutral to the control devices in panel, selector switches, input choke for 20 HP control contractors and main contactors at the output of VFD, terminal blocks, power and control wiring to the entire. |
| 314 | Automatic Power Factor Control panel (APFC) upto 10KVAR with monitoring power factor of electrical system using sensors and micro processores |
| 315 | Supply of of 10 sq.mm. 3 core Copper conductor P.V.C. insulated submersible cable |
| 316 | Supply of Earthing materials as per specification and site Requirment |
| 317 | Supply of Main piping and valves as per specification and site Requirment |
| 318 | SITC of AC based diaphram operated dual solenoid control valve sluice valve (2 Nos) for flow / presssure / level controlling with controller / RTU PN 10/16, Bonnet- DI (GGG-50), tubing SS304, capable to transmit / communicate data to MIS as well as local control room server of 80 mm dia delivery pipeline. |
| 319 | Supply of 40KVA automatic voltage regulator (compact) servo controlled stabilizer with accessories as per specification and site Requirement |
| 320 | Supply of chain pulley 3.0 tonne capacity with 4.5mt.lift . |
| 321 | Supply of Gauges as per specification |
| 322 | Supply of Rubber Insulation sheet 1mt. x 2mt.x 0.025 mtr. |
| 323 | Supply of 100 Amp. TPN Main Switch |
| 324 | Installation, commissioning and Testing of all pumping plant & Accessoriees complete |
| 325 | Painting of entire installation with 2 coats of super enamel paint as per direction of Engineer-In-Charge of works. |
| 326 | Fire exhtenguisher (6Kg) |
| 327 | Tools and Spanners – |
| 328 | Autophase reseval Unit (APR) Panel as per specifications. |
| 329 | Internal & external Electrification of Pump house |
| 330 | Intelligent GSM/Web/PLC based Mini Remote Terminal Units/PLC with analog and digital parameters and features as specified mini T.W. and transmit data on GSM backbone. GSM based wireless Communication system capable to transfer and gather data from remote sites to master Control Stations (Voltage, Current, Power factor, Pumping running Hour etc.) with 6 Amp. Automatic Voltage stabilizer including high and low cut and isolation transformer including Erection, testing and commissioining and modification of starter with AC and DC relays and necessary wiring complete in all respect. |
| 331 | Data commmunication gatway devices for data acquisition and communication to IOT based cloud server centralized system with stand protocol using wi-fi / GPRS ethernet for atteast 02 months data backup with all accessories. |
| 332 | Over voltage & under voltage trip protection (350 V-450 V) |
| 333 | IOT based intelligent Pressure transmitter capable to communicate / transmit data to MIS as well as local control room servor for tubewell |
| 334 | IOT based Electro magnetic flow meter of 80 mm size capable to communicate / transmit data to MIS as well as local control room servor for tubewell. |
| 335 | SITC of depth sensor for tubewell (upto 100 mt range) with non vented pressure sensor, sensor cable and necessary accessories complete as per technical specification hydrostatic level transmitter should be capable of transmitting data to SCADA system and portal. |
| 336 | Online TDS, PH Mete with communication, measuring with LCD display |
| 337 | CCTV camera with 2 MP, IP dome CCTV colour night vision, Dline 2 port POE switch full Giga, D link connector PVC box, complete wireless communication setup and 128 GB memory card. |
| 338 | UPS of suitable capacity for control supply of automation |
| 339 | SITC of ultrasonic type level transmitter for GLSR complete. |
| 340 | Signal cabling between RTU/PLC and field instruments including screened/unscreened & control copper cable, etc complete in all respect |
| 341 | S.I.T.C. of Submersible Pumping Plant with Accessories for Prop TW Jijhari To Prop Sump Jijhari |
| 342 | Supply of Submersible pump and motor set: 550 L.P.M. discharge at 70mts. NEH. |
| 343 | Supply of Submersible pump and motor set: 550 L.P.M. discharge at 70 mts. NEH. as spare. |
| 344 | Providing, Installation and commissioning of Power coated and CNC fabricated electric control panel upto 20 HP submersible pump set, 14 SWCG CRCA sheet thickness of energy saving variable frequency starter of 20 HP heavy duty which will operate submersible pump coomprises of which includes F-MCCB AMP, Spreader links, rotary handles, red, yellow, blue and Amber indicators, current transformers (CT's), multi function meter which will indicate PF, THD, current, voltage, KWH and KVar etc. MCB's, voltage protections devices, surge protection devices which will handle type I and type 2 surges, control transformers to provide proper phase and neutral to the control devices in panel, selector switches, input choke for 20 HP control contractors and main contactors at the output of VFD, terminal blocks, power and control wiring to the entire. |
| 345 | Automatic Power Factor Control panel (APFC) upto 10KVAR with monitoring power factor of electrical system using sensors and micro processores |
| 346 | Supply of of 10 sq.mm. 3 core Copper conductor P.V.C. insulated submersible cable |
| 347 | Supply of Earthing materials as per specification and site Requirment |
| 348 | Supply of Main piping and valves as per specification and site Requirment |
| 349 | SITC of AC based diaphram operated dual solenoid control valve sluice valve (2 Nos) for flow / presssure / level controlling with controller / RTU PN 10/16, Bonnet- DI (GGG-50), tubing SS304, capable to transmit / communicate data to MIS as well as local control room server of 80 mm dia delivery pipeline. |
| 350 | Supply of 40KVA automatic voltage regulator (compact) servo controlled stabilizer with accessories as per specification and site Requirement |
| 351 | Supply of chain pulley 3.0 tonne capacity with 4.5mt.lift . |
| 352 | Supply of Gauges as per specification |
| 353 | Supply of Rubber Insulation sheet 1mt. x 2mt.x 0.025 mtr. |
| 354 | Supply of 100 Amp. TPN Main Switch |
| 355 | Installation, commissioning and Testing of all pumping plant & Accessoriees complete |
| 356 | Painting of entire installation with 2 coats of super enamel paint as per direction of Engineer-In-Charge of works. |
| 357 | Fire exhtenguisher (6Kg) |
| 358 | Tools and Spanners – |
| 359 | Autophase reseval Unit (APR) Panel as per specifications. |
| 360 | Internal & external Electrification of Pump house |
| 361 | Intelligent GSM/Web/PLC based Mini Remote Terminal Units/PLC with analog and digital parameters and features as specified mini T.W. and transmit data on GSM backbone. GSM based wireless Communication system capable to transfer and gather data from remote sites to master Control Stations (Voltage, Current, Power factor, Pumping running Hour etc.) with 6 Amp. Automatic Voltage stabilizer including high and low cut and isolation transformer including Erection, testing and commissioining and modification of starter with AC and DC relays and necessary wiring complete in all respect. |
| 362 | Data commmunication gatway devices for data acquisition and communication to IOT based cloud server centralized system with stand protocol using wi-fi / GPRS ethernet for atteast 02 months data backup with all accessories. |
| 363 | Over voltage & under voltage trip protection (350 V-450 V) |
| 364 | IOT based intelligent Pressure transmitter capable to communicate / transmit data to MIS as well as local control room servor for tubewell |
| 365 | IOT based Electro magnetic flow meter of 80 mm size capable to communicate / transmit data to MIS as well as local control room servor for tubewell. |
| 366 | SITC of depth sensor for tubewell (upto 100 mt range) with non vented pressure sensor, sensor cable and necessary accessories complete as per technical specification hydrostatic level transmitter should be capable of transmitting data to SCADA system and portal. |
| 367 | Supply, installation, testing and commissioning of online Chlorine, pH and TDS measuring unit for water supply system, suitable for continuous monitoring of treated/raw water quality, complete with industrial-grade pH sensor and TDS sensor with necessary flow cell / immersion arrangement, automatic temperature compensation, digital transmitter and display unit.The system shall be operable on AC power supply as well as solar power with provision of solar panel, charge controllerand battery backup, ensuring uninterrupted operation. The unit shall be complete with control and communication module capable of transmitting real-time pH and TDS data, alarms and system status to the Monitoring & Control System (MCS) / SCADA through suitable communication protocol (RS-485 / GSM / NB-IoT / Ethernet as applicable). The system shall include enclosure of minimum IP-65 protection, mounting structure, signal and power cables, cable glands, earthing, software configuration, calibration, testing, commissioning and integration with MCS, complete in all respects as per tender document specifications. |
| 368 | CCTV camera with 2 MP, IP dome CCTV colour night vision, Dline 2 port POE switch full Giga, D link connector PVC box, complete wireless communication setup and 128 GB memory card. |
| 369 | UPS of suitable capacity for control supply of automation |
| 370 | SITC of ultrasonic type level transmitter for GLSR complete. |
| 371 | Signal cabling between RTU/PLC and field instruments including screened/unscreened & control copper cable, etc complete in all respect |
| 372 | S.I.T.C. of Submersible Pumping Plant with Accessories for EX TW Tallital -1 To Prop Sump Tallital |
| 373 | Supply of Submersible pump and motor set: 600 L.P.M. discharge at 70mts. NEH. |
| 374 | Supply of Submersible pump and motor set: 600 L.P.M. discharge at 70 mts. NEH. as spare. |
| 375 | Providing, Installation and commissioning of Power coated and CNC fabricated electric control panel upto 20 HP submersible pump set, 14 SWCG CRCA sheet thickness of energy saving variable frequency starter of 20 HP heavy duty which will operate submersible pump coomprises of which includes F-MCCB AMP, Spreader links, rotary handles, red, yellow, blue and Amber indicators, current transformers (CT's), multi function meter which will indicate PF, THD, current, voltage, KWH and KVar etc. MCB's, voltage protections devices, surge protection devices which will handle type I and type 2 surges, control transformers to provide proper phase and neutral to the control devices in panel, selector switches, input choke for 20 HP control contractors and main contactors at the output of VFD, terminal blocks, power and control wiring to the entire. |
| 376 | Automatic Power Factor Control panel (APFC) upto 10KVAR with monitoring power factor of electrical system using sensors and micro processores |
| 377 | Supply of of 10 sq.mm. 3 core Copper conductor P.V.C. insulated submersible cable |
| 378 | Supply of Earthing materials as per specification and site Requirment |
| 379 | Supply of Main piping and valves as per specification and site Requirment |
| 380 | SITC of AC based diaphram operated dual solenoid control valve sluice valve (2 Nos) for flow / presssure / level controlling with controller / RTU PN 10/16, Bonnet- DI (GGG-50), tubing SS304, capable to transmit / communicate data to MIS as well as local control room server of 80 mm dia delivery pipeline. |
| 381 | Supply of 40KVA automatic voltage regulator (compact) servo controlled stabilizer with accessories as per specification and site Requirement |
| 382 | Supply of chain pulley 3.0 tonne capacity with 4.5mt.lift . |
| 383 | Supply of Gauges as per specification |
| 384 | Supply of Rubber Insulation sheet 1mt. x 2mt.x 0.025 mtr. |
| 385 | Supply of 100 Amp. TPN Main Switch |
| 386 | Installation, commissioning and Testing of all pumping plant & Accessoriees complete |
| 387 | Painting of entire installation with 2 coats of super enamel paint as per direction of Engineer-In-Charge of works. |
| 388 | Fire exhtenguisher (6Kg) |
| 389 | Tools and Spanners – |
| 390 | Autophase reseval Unit (APR) Panel as per specifications. |
| 391 | Internal & external Electrification of Pump house |
| 392 | Intelligent GSM/Web/PLC based Mini Remote Terminal Units/PLC with analog and digital parameters and features as specified mini T.W. and transmit data on GSM backbone. GSM based wireless Communication system capable to transfer and gather data from remote sites to master Control Stations (Voltage, Current, Power factor, Pumping running Hour etc.) with 6 Amp. Automatic Voltage stabilizer including high and low cut and isolation transformer including Erection, testing and commissioining and modification of starter with AC and DC relays and necessary wiring complete in all respect. |
| 393 | Data commmunication gatway devices for data acquisition and communication to IOT based cloud server centralized system with stand protocol using wi-fi / GPRS ethernet for atteast 02 months data backup with all accessories. |
| 394 | Over voltage & under voltage trip protection (350 V-450 V) |
| 395 | IOT based intelligent Pressure transmitter capable to communicate / transmit data to MIS as well as local control room servor for tubewell |
| 396 | IOT based Electro magnetic flow meter of 80 mm size capable to communicate / transmit data to MIS as well as local control room servor for tubewell. |
| 397 | SITC of depth sensor for tubewell (upto 100 mt range) with non vented pressure sensor, sensor cable and necessary accessories complete as per technical specification hydrostatic level transmitter should be capable of transmitting data to SCADA system and portal. |
| 398 | Supply, installation, testing and commissioning of online Chlorine, pH and TDS measuring unit for water supply system, suitable for continuous monitoring of treated/raw water quality, complete with industrial-grade pH sensor and TDS sensor with necessary flow cell / immersion arrangement, automatic temperature compensation, digital transmitter and display unit.The system shall be operable on AC power supply as well as solar power with provision of solar panel, charge controllerand battery backup, ensuring uninterrupted operation. The unit shall be complete with control and communication module capable of transmitting real-time pH and TDS data, alarms and system status to the Monitoring & Control System (MCS) / SCADA through suitable communication protocol (RS-485 / GSM / NB-IoT / Ethernet as applicable). The system shall include enclosure of minimum IP-65 protection, mounting structure, signal and power cables, cable glands, earthing, software configuration, calibration, testing, commissioning and integration with MCS, complete in all respects as per tender document specifications. |
| 399 | CCTV camera with 2 MP, IP dome CCTV colour night vision, Dline 2 port POE switch full Giga, D link connector PVC box, complete wireless communication setup and 128 GB memory card. |
| 400 | UPS of suitable capacity for control supply of automation |
| 401 | SITC of ultrasonic type level transmitter for GLSR complete. |
| 402 | Signal cabling between RTU/PLC and field instruments including screened/unscreened & control copper cable, etc complete in all respect |
| 403 | S.I.T.C. of Submersible Pumping Plant with Accessories for Prop TW-1 & TW-2 Naldamayanti Lake To Prop Sump Naldamayanti Lake (2 Nos.) |
| 404 | Supply of Submersible pump and motor set: 350 L.P.M. discharge at 90mts. NEH. |
| 405 | Supply of Submersible pump and motor set: 350 L.P.M. discharge at 90 mts. NEH. as spare. |
| 406 | Providing, Installation and commissioning of Power coated and CNC fabricated electric control panel upto 15 HP submersible pump set, 14 SWCG CRCA sheet thickness of energy saving variable frequency starter of 15 HP heavy duty which will operate submersible pump coomprises of which includes F-MCCB AMP, Spreader links, rotary handles, red, yellow, blue and Amber indicators, current transformers (CT's), multi function meter which will indicate PF, THD, current, voltage, KWH and KVar etc. MCB's, voltage protections devices, surge protection devices which will handle type I and type 2 surges, control transformers to provide proper phase and neutral to the control devices in panel, selector switches, input choke for 15 HP control contractors and main contactors at the output of VFD, terminal blocks, power and control wiring to the entire. |
| 407 | Automatic Power Factor Control panel (APFC) upto 10KVAR with monitoring power factor of electrical system using sensors and micro processores |
| 408 | Supply of of 10 sq.mm. 3 core Copper conductor P.V.C. insulated submersible cable |
| 409 | Supply of Earthing materials as per specification and site Requirment |
| 410 | Supply of Main piping and valves as per specification and site Requirment |
| 411 | SITC of AC based diaphram operated dual solenoid control valve sluice valve (2 Nos) for flow / presssure / level controlling with controller / RTU PN 10/16, Bonnet- DI (GGG-50), tubing SS304, capable to transmit / communicate data to MIS as well as local control room server of 80 mm dia delivery pipeline. |
| 412 | Supply of 30KVA automatic voltage regulator (compact) servo controlled stabilizer with accessories as per specification and site Requirement |
| 413 | Supply of chain pulley 3.0 tonne capacity with 4.5mt.lift . |
| 414 | Supply of Gauges as per specification |
| 415 | Supply of Rubber Insulation sheet 1mt. x 2mt.x 0.025 mtr. |
| 416 | Supply of 100 Amp. TPN Main Switch |
| 417 | Installation, commissioning and Testing of all pumping plant & Accessoriees complete |
| 418 | Painting of entire installation with 2 coats of super enamel paint as per direction of Engineer-In-Charge of works. |
| 419 | Fire exhtenguisher (6Kg) |
| 420 | Tools and Spanners – |
| 421 | Autophase reseval Unit (APR) Panel as per specifications. |
| 422 | Internal & external Electrification of Pump house |
| 423 | Intelligent GSM/Web/PLC based Mini Remote Terminal Units/PLC with analog and digital parameters and features as specified mini T.W. and transmit data on GSM backbone. GSM based wireless Communication system capable to transfer and gather data from remote sites to master Control Stations (Voltage, Current, Power factor, Pumping running Hour etc.) with 6 Amp. Automatic Voltage stabilizer including high and low cut and isolation transformer including Erection, testing and commissioining and modification of starter with AC and DC relays and necessary wiring complete in all respect. |
| 424 | Data commmunication gatway devices for data acquisition and communication to IOT based cloud server centralized system with stand protocol using wi-fi / GPRS ethernet for atteast 02 months data backup with all accessories. |
| 425 | Over voltage & under voltage trip protection (350 V-450 V) |
| 426 | IOT based intelligent Pressure transmitter capable to communicate / transmit data to MIS as well as local control room servor for tubewell |
| 427 | IOT based Electro magnetic flow meter of 80 mm size capable to communicate / transmit data to MIS as well as local control room servor for tubewell. |
| 428 | SITC of depth sensor for tubewell (upto 100 mt range) with non vented pressure sensor, sensor cable and necessary accessories complete as per technical specification hydrostatic level transmitter should be capable of transmitting data to SCADA system and portal. |
| 429 | Supply, installation, testing and commissioning of online Chlorine, pH and TDS measuring unit for water supply system, suitable for continuous monitoring of treated/raw water quality, complete with industrial-grade pH sensor and TDS sensor with necessary flow cell / immersion arrangement, automatic temperature compensation, digital transmitter and display unit.The system shall be operable on AC power supply as well as solar power with provision of solar panel, charge controllerand battery backup, ensuring uninterrupted operation. The unit shall be complete with control and communication module capable of transmitting real-time pH and TDS data, alarms and system status to the Monitoring & Control System (MCS) / SCADA through suitable communication protocol (RS-485 / GSM / NB-IoT / Ethernet as applicable). The system shall include enclosure of minimum IP-65 protection, mounting structure, signal and power cables, cable glands, earthing, software configuration, calibration, testing, commissioning and integration with MCS, complete in all respects as per tender document specifications. |
| 430 | CCTV camera with 2 MP, IP dome CCTV colour night vision, Dline 2 port POE switch full Giga, D link connector PVC box, complete wireless communication setup and 128 GB memory card. |
| 431 | UPS of suitable capacity for control supply of automation |
| 432 | SITC of ultrasonic type level transmitter for GLSR complete. |
| 433 | Signal cabling between RTU/PLC and field instruments including screened/unscreened & control copper cable, etc complete in all respect |
| 434 | S.I.T.C. of Submersible Pumping Plant with Accessories for Prop TW Tallital To Prop Sump Tallital |
| 435 | Supply of Submersible pump and motor set: 400 L.P.M. discharge at 70mts. NEH. |
| 436 | Supply of Submersible pump and motor set: 400 L.P.M. discharge at 70 mts. NEH. as spare. |
| 437 | Providing, Installation and commissioning of Power coated and CNC fabricated electric control panel upto 15 HP submersible pump set, 14 SWCG CRCA sheet thickness of energy saving variable frequency starter of 15 HP heavy duty which will operate submersible pump coomprises of which includes F-MCCB AMP, Spreader links, rotary handles, red, yellow, blue and Amber indicators, current transformers (CT's), multi function meter which will indicate PF, THD, current, voltage, KWH and KVar etc. MCB's, voltage protections devices, surge protection devices which will handle type I and type 2 surges, control transformers to provide proper phase and neutral to the control devices in panel, selector switches, input choke for 15 HP control contractors and main contactors at the output of VFD, terminal blocks, power and control wiring to the entire. |
| 438 | Automatic Power Factor Control panel (APFC) upto 10KVAR with monitoring power factor of electrical system using sensors and micro processores |
| 439 | Supply of of 10 sq.mm. 3 core Copper conductor P.V.C. insulated submersible cable |
| 440 | Supply of Earthing materials as per specification and site Requirment |
| 441 | Supply of Main piping and valves as per specification and site Requirment |
| 442 | SITC of AC based diaphram operated dual solenoid control valve sluice valve (2 Nos) for flow / presssure / level controlling with controller / RTU PN 10/16, Bonnet- DI (GGG-50), tubing SS304, capable to transmit / communicate data to MIS as well as local control room server of 80 mm dia delivery pipeline. |
| 443 | Supply of 30KVA automatic voltage regulator (compact) servo controlled stabilizer with accessories as per specification and site Requirement |
| 444 | Supply of chain pulley 3.0 tonne capacity with 4.5mt.lift . |
| 445 | Supply of Gauges as per specification |
| 446 | Supply of Rubber Insulation sheet 1mt. x 2mt.x 0.025 mtr. |
| 447 | Supply of 100 Amp. TPN Main Switch |
| 448 | Installation, commissioning and Testing of all pumping plant & Accessoriees complete |
| 449 | Painting of entire installation with 2 coats of super enamel paint as per direction of Engineer-In-Charge of works. |
| 450 | Fire exhtenguisher (6Kg) |
| 451 | Tools and Spanners – |
| 452 | Autophase reseval Unit (APR) Panel as per specifications. |
| 453 | Internal & external Electrification of Pump house |
| 454 | Intelligent GSM/Web/PLC based Mini Remote Terminal Units/PLC with analog and digital parameters and features as specified mini T.W. and transmit data on GSM backbone. GSM based wireless Communication system capable to transfer and gather data from remote sites to master Control Stations (Voltage, Current, Power factor, Pumping running Hour etc.) with 6 Amp. Automatic Voltage stabilizer including high and low cut and isolation transformer including Erection, testing and commissioining and modification of starter with AC and DC relays and necessary wiring complete in all respect. |
| 455 | Data commmunication gateway devices for data acquisition and communication to IOT based cloud server centralized system with stand protocol using wi-fi / GPRS ethernet for atteast 02 months data backup with all accessories. |
| 456 | Over voltage & under voltage trip protection (350 V-450 V) |
| 457 | IOT based intelligent Pressure transmitter capable to communicate / transmit data to MIS as well as local control room servor for tubewell |
| 458 | IOT based Electro magnetic flow meter of 80 mm size capable to communicate / transmit data to MIS as well as local control room servor for tubewell. |
| 459 | SITC of depth sensor for tubewell (upto 100 mt range) with non vented pressure sensor, sensor cable and necessary accessories complete as per technical specification hydrostatic level transmitter should be capable of transmitting data to SCADA system and portal. |
| 460 | Supply, installation, testing and commissioning of online Chlorine, pH and TDS measuring unit for water supply system, suitable for continuous monitoring of treated/raw water quality, complete with industrial-grade pH sensor and TDS sensor with necessary flow cell / immersion arrangement, automatic temperature compensation, digital transmitter and display unit.The system shall be operable on AC power supply as well as solar power with provision of solar panel, charge controllerand battery backup, ensuring uninterrupted operation. The unit shall be complete with control and communication module capable of transmitting real-time pH and TDS data, alarms and system status to the Monitoring & Control System (MCS) / SCADA through suitable communication protocol (RS-485 / GSM / NB-IoT / Ethernet as applicable). The system shall include enclosure of minimum IP-65 protection, mounting structure, signal and power cables, cable glands, earthing, software configuration, calibration, testing, commissioning and integration with MCS, complete in all respects as per tender document specifications. |
| 461 | CCTV camera with 2 MP, IP dome CCTV colour night vision, Dline 2 port POE switch full Giga, D link connector PVC box, complete wireless communication setup and 128 GB memory card. |
| 462 | UPS of suitable capacity for control supply of automation |
| 463 | SITC of ultrasonic type level transmitter for GLSR complete. |
| 464 | Signal cabling between RTU/PLC and field instruments including screened/unscreened & control copper cable, etc complete in all respect |
| 465 | S.I.T.C. of Submersible Pumping Plant with Accessories for Prop TW Silauti pant To Prop Sump Silauti pant |
| 466 | Supply of Submersible pump and motor set: 350 L.P.M. discharge at 100mts. NEH. |
| 467 | Supply of Submersible pump and motor set: 350 L.P.M. discharge at 100 mts. NEH. as spare. |
| 468 | Providing, Installation and commissioning of Power coated and CNC fabricated electric control panel upto 15 HP submersible pump set, 14 SWCG CRCA sheet thickness of energy saving variable frequency starter of 15 HP heavy duty which will operate submersible pump coomprises of which includes F-MCCB AMP, Spreader links, rotary handles, red, yellow, blue and Amber indicators, current transformers (CT's), multi function meter which will indicate PF, THD, current, voltage, KWH and KVar etc. MCB's, voltage protections devices, surge protection devices which will handle type I and type 2 surges, control transformers to provide proper phase and neutral to the control devices in panel, selector switches, input choke for 15 HP control contractors and main contactors at the output of VFD, terminal blocks, power and control wiring to the entire. |
| 469 | Automatic Power Factor Control panel (APFC) upto 10KVAR with monitoring power factor of electrical system using sensors and micro processores |
| 470 | Supply of of 10 sq.mm. 3 core Copper conductor P.V.C. insulated submersible cable |
| 471 | Supply of Earthing materials as per specification and site Requirment |
| 472 | Supply of Main piping and valves as per specification and site Requirment |
| 473 | SITC of AC based diaphram operated dual solenoid control valve sluice valve (2 Nos) for flow / presssure / level controlling with controller / RTU PN 10/16, Bonnet- DI (GGG-50), tubing SS304, capable to transmit / communicate data to MIS as well as local control room server of 80 mm dia delivery pipeline. |
| 474 | Supply of 30KVA automatic voltage regulator (compact) servo controlled stabilizer with accessories as per specification and site Requirement |
| 475 | Supply of chain pulley 3.0 tonne capacity with 4.5mt.lift . |
| 476 | Supply of Gauges as per specification |
| 477 | Supply of Rubber Insulation sheet 1mt. x 2mt.x 0.025 mtr. |
| 478 | Supply of 100 Amp. TPN Main Switch |
| 479 | Installation, commissioning and Testing of all pumping plant & Accessoriees complete |
| 480 | Painting of entire installation with 2 coats of super enamel paint as per direction of Engineer-In-Charge of works. |
| 481 | Fire exhtenguisher (6Kg) |
| 482 | Tools and Spanners – |
| 483 | Autophase reseval Unit (APR) Panel as per specifications. |
| 484 | Internal & external Electrification of Pump house |
| 485 | Intelligent GSM/Web/PLC based Mini Remote Terminal Units/PLC with analog and digital parameters and features as specified mini T.W. and transmit data on GSM backbone. GSM based wireless Communication system capable to transfer and gather data from remote sites to master Control Stations (Voltage, Current, Power factor, Pumping running Hour etc.) with 6 Amp. Automatic Voltage stabilizer including high and low cut and isolation transformer including Erection, testing and commissioining and modification of starter with AC and DC relays and necessary wiring complete in all respect. |
| 486 | Data commmunication gatway devices for data acquisition and communication to IOT based cloud server centralized system with stand protocol using wi-fi / GPRS ethernet for atteast 02 months data backup with all accessories. |
| 487 | Over voltage & under voltage trip protection (350 V-450 V) |
| 488 | IOT based intelligent Pressure transmitter capable to communicate / transmit data to MIS as well as local control room servor for tubewell |
| 489 | IOT based Electro magnetic flow meter of 80 mm size capable to communicate / transmit data to MIS as well as local control room servor for tubewell. |
| 490 | SITC of depth sensor for tubewell (upto 100 mt range) with non vented pressure sensor, sensor cable and necessary accessories complete as per technical specification hydrostatic level transmitter should be capable of transmitting data to SCADA system and portal. |
| 491 | Supply, installation, testing and commissioning of online Chlorine, pH and TDS measuring unit for water supply system, suitable for continuous monitoring of treated/raw water quality, complete with industrial-grade pH sensor and TDS sensor with necessary flow cell / immersion arrangement, automatic temperature compensation, digital transmitter and display unit.The system shall be operable on AC power supply as well as solar power with provision of solar panel, charge controllerand battery backup, ensuring uninterrupted operation. The unit shall be complete with control and communication module capable of transmitting real-time pH and TDS data, alarms and system status to the Monitoring & Control System (MCS) / SCADA through suitable communication protocol (RS-485 / GSM / NB-IoT / Ethernet as applicable). The system shall include enclosure of minimum IP-65 protection, mounting structure, signal and power cables, cable glands, earthing, software configuration, calibration, testing, commissioning and integration with MCS, complete in all respects as per tender document specifications. |
| 492 | CCTV camera with 2 MP, IP dome CCTV colour night vision, Dline 2 port POE switch full Giga, D link connector PVC box, complete wireless communication setup and 128 GB memory card. |
| 493 | UPS of suitable capacity for control supply of automation |
| 494 | SITC of ultrasonic type level transmitter for GLSR complete. |
| 495 | Signal cabling between RTU/PLC and field instruments including screened/unscreened & control copper cable, etc complete in all respect |
| 496 | S.I.T.C. of Submersible Pumping Plant with Accessories for Prop TW-2 Naul To Prop Sump Naul |
| 497 | Supply of Submersible pump and motor set: 250 L.P.M. discharge at 115 mts. NEH. |
| 498 | Supply of Submersible pump and motor set: 250 L.P.M. discharge at 115 mts. NEH. as spare. |
| 499 | Providing, Installation and commissioning of Power coated and CNC fabricated electric control panel upto 15 HP submersible pump set, 14 SWCG CRCA sheet thickness of energy saving variable frequency starter of 15 HP heavy duty which will operate submersible pump coomprises of which includes F-MCCB AMP, Spreader links, rotary handles, red, yellow, blue and Amber indicators, current transformers (CT's), multi function meter which will indicate PF, THD, current, voltage, KWH and KVar etc. MCB's, voltage protections devices, surge protection devices which will handle type I and type 2 surges, control transformers to provide proper phase and neutral to the control devices in panel, selector switches, input choke for 15 HP control contractors and main contactors at the output of VFD, terminal blocks, power and control wiring to the entire. |
| 500 | Automatic Power Factor Control panel (APFC) upto 10KVAR with monitoring power factor of electrical system using sensors and micro processores |
| 501 | Supply of of 10 sq.mm. 3 core Copper conductor P.V.C. insulated submersible cable |
| 502 | Supply of Earthing materials as per specification and site Requirment |
| 503 | Supply of Main piping and valves as per specification and site Requirment |
| 504 | SITC of AC based diaphram operated dual solenoid control valve sluice valve (2 Nos) for flow / presssure / level controlling with controller / RTU PN 10/16, Bonnet- DI (GGG-50), tubing SS304, capable to transmit / communicate data to MIS as well as local control room server of 80 mm dia delivery pipeline. |
| 505 | Supply of 30KVA automatic voltage regulator (compact) servo controlled stabilizer with accessories as per specification and site Requirement |
| 506 | Supply of chain pulley 3.0 tonne capacity with 4.5mt.lift . |
| 507 | Supply of Gauges as per specification |
| 508 | Supply of Rubber Insulation sheet 1mt. x 2mt.x 0.025 mtr. |
| 509 | Supply of 100 Amp. TPN Main Switch |
| 510 | Installation, commissioning and Testing of all pumping plant & Accessoriees complete |
| 511 | Painting of entire installation with 2 coats of super enamel paint as per direction of Engineer-In-Charge of works. |
| 512 | Fire exhtenguisher (6Kg) |
| 513 | Tools and Spanners – |
| 514 | Autophase reseval Unit (APR) Panel as per specifications. |
| 515 | Internal & external Electrification of Pump house |
| 516 | Intelligent GSM/Web/PLC based Mini Remote Terminal Units/PLC with analog and digital parameters and features as specified mini T.W. and transmit data on GSM backbone. GSM based wireless Communication system capable to transfer and gather data from remote sites to master Control Stations (Voltage, Current, Power factor, Pumping running Hour etc.) with 6 Amp. Automatic Voltage stabilizer including high and low cut and isolation transformer including Erection, testing and commissioining and modification of starter with AC and DC relays and necessary wiring complete in all respect. |
| 517 | Data commmunication gatway devices for data acquisition and communication to IOT based cloud server centralized system with stand protocol using wi-fi / GPRS ethernet for atteast 02 months data backup with all accessories. |
| 518 | Over voltage & under voltage trip protection (350 V-450 V) |
| 519 | IOT based intelligent Pressure transmitter capable to communicate / transmit data to MIS as well as local control room servor for tubewell |
| 520 | IOT based Electro magnetic flow meter of 80 mm size capable to communicate / transmit data to MIS as well as local control room servor for tubewell. |
| 521 | SITC of depth sensor for tubewell (upto 100 mt range) with non vented pressure sensor, sensor cable and necessary accessories complete as per technical specification hydrostatic level transmitter should be capable of transmitting data to SCADA system and portal. |
| 522 | Supply, installation, testing and commissioning of online Chlorine, pH and TDS measuring unit for water supply system, suitable for continuous monitoring of treated/raw water quality, complete with industrial-grade pH sensor and TDS sensor with necessary flow cell / immersion arrangement, automatic temperature compensation, digital transmitter and display unit.The system shall be operable on AC power supply as well as solar power with provision of solar panel, charge controllerand battery backup, ensuring uninterrupted operation. The unit shall be complete with control and communication module capable of transmitting real-time pH and TDS data, alarms and system status to the Monitoring & Control System (MCS) / SCADA through suitable communication protocol (RS-485 / GSM / NB-IoT / Ethernet as applicable). The system shall include enclosure of minimum IP-65 protection, mounting structure, signal and power cables, cable glands, earthing, software configuration, calibration, testing, commissioning and integration with MCS, complete in all respects as per tender document specifications. |
| 523 | CCTV camera with 2 MP, IP dome CCTV colour night vision, Dline 2 port POE switch full Giga, D link connector PVC box, complete wireless communication setup and 128 GB memory card. |
| 524 | UPS of suitable capacity for control supply of automation |
| 525 | SITC of ultrasonic type level transmitter for GLSR complete. |
| 526 | Signal cabling between RTU/PLC and field instruments including screened/unscreened & control copper cable, etc complete in all respect |
| 527 | S.I.T.C. of Submersible Pumping Plant with Accessories for Prop TW-1 Naul To Prop Sump Naul |
| 528 | Supply of Submersible pump and motor set: 250 L.P.M. discharge at 110 mts. NEH. |
| 529 | Supply of Submersible pump and motor set: 250 L.P.M. discharge at 110 mts. NEH. as spare. |
| 530 | Providing, Installation and commissioning of Power coated and CNC fabricated electric control panel upto 12.5 HP submersible pump set, 14 SWCG CRCA sheet thickness of energy saving variable frequency starter of 12.5 HP heavy duty which will operate submersible pump coomprises of which includes F-MCCB AMP, Spreader links, rotary handles, red, yellow, blue and Amber indicators, current transformers (CT's), multi function meter which will indicate PF, THD, current, voltage, KWH and KVar etc. MCB's, voltage protections devices, surge protection devices which will handle type I and type 2 surges, control transformers to provide proper phase and neutral to the control devices in panel, selector switches, input choke for 12.5 HP control contractors and main contactors at the output of VFD, terminal blocks, power and control wiring to the entire. |
| 531 | Automatic Power Factor Control panel (APFC) upto 10KVAR with monitoring power factor of electrical system using sensors and micro processores |
| 532 | Supply of of 06 sq.mm. 3 core Copper conductor P.V.C. insulated submersible cable |
| 533 | Supply of Earthing materials as per specification and site Requirment |
| 534 | Supply of Main piping and valves as per specification and site Requirment |
| 535 | SITC of AC based diaphram operated dual solenoid control valve sluice valve (2 Nos) for flow / presssure / level controlling with controller / RTU PN 10/16, Bonnet- DI (GGG-50), tubing SS304, capable to transmit / communicate data to MIS as well as local control room server of 80 mm dia delivery pipeline. |
| 536 | Supply of 20KVA automatic voltage regulator (compact) servo controlled stabilizer with accessories as per specification and site Requirement |
| 537 | Supply of chain pulley 3.0 tonne capacity with 4.5mt.lift . |
| 538 | Supply of Gauges as per specification |
| 539 | Supply of Rubber Insulation sheet 1mt. x 2mt.x 0.025 mtr. |
| 540 | Supply of 63 Amp. TPN Main Switch |
| 541 | Installation, commissioning and Testing of all pumping plant & Accessoriees complete |
| 542 | Painting of entire installation with 2 coats of super enamel paint as per direction of Engineer-In-Charge of works. |
| 543 | Fire exhtenguisher (6Kg) |
| 544 | Tools and Spanners – |
| 545 | Autophase reseval Unit (APR) Panel as per specifications. |
| 546 | Internal & external Electrification of Pump house |
| 547 | Intelligent GSM/Web/PLC based Mini Remote Terminal Units/PLC with analog and digital parameters and features as specified mini T.W. and transmit data on GSM backbone. GSM based wireless Communication system capable to transfer and gather data from remote sites to master Control Stations (Voltage, Current, Power factor, Pumping running Hour etc.) with 6 Amp. Automatic Voltage stabilizer including high and low cut and isolation transformer including Erection, testing and commissioining and modification of starter with AC and DC relays and necessary wiring complete in all respect. |
| 548 | Data commmunication gatway devices for data acquisition and communication to IOT based cloud server centralized system with stand protocol using wi-fi / GPRS ethernet for atteast 02 months data backup with all accessories. |
| 549 | Over voltage & under voltage trip protection (350 V-450 V) |
| 550 | IOT based intelligent Pressure transmitter capable to communicate / transmit data to MIS as well as local control room servor for tubewell |
| 551 | IOT based Electro magnetic flow meter of 80 mm size capable to communicate / transmit data to MIS as well as local control room servor for tubewell. |
| 552 | SITC of depth sensor for tubewell (upto 100 mt range) with non vented pressure sensor, sensor cable and necessary accessories complete as per technical specification hydrostatic level transmitter should be capable of transmitting data to SCADA system and portal. |
| 553 | Supply, installation, testing and commissioning of online Chlorine, pH and TDS measuring unit for water supply system, suitable for continuous monitoring of treated/raw water quality, complete with industrial-grade pH sensor and TDS sensor with necessary flow cell / immersion arrangement, automatic temperature compensation, digital transmitter and display unit.The system shall be operable on AC power supply as well as solar power with provision of solar panel, charge controllerand battery backup, ensuring uninterrupted operation. The unit shall be complete with control and communication module capable of transmitting real-time pH and TDS data, alarms and system status to the Monitoring & Control System (MCS) / SCADA through suitable communication protocol (RS-485 / GSM / NB-IoT / Ethernet as applicable). The system shall include enclosure of minimum IP-65 protection, mounting structure, signal and power cables, cable glands, earthing, software configuration, calibration, testing, commissioning and integration with MCS, complete in all respects as per tender document specifications. |
| 554 | CCTV camera with 2 MP, IP dome CCTV colour night vision, Dline 2 port POE switch full Giga, D link connector PVC box, complete wireless communication setup and 128 GB memory card. |
| 555 | UPS of suitable capacity for control supply of automation |
| 556 | SITC of ultrasonic type level transmitter for GLSR complete. |
| 557 | Signal cabling between RTU/PLC and field instruments including screened/unscreened & control copper cable, etc complete in all respect |
| 558 | S.I.T.C. of Submersible Pumping Plant with Accessories for Ex TW Tallital-2 To Prop sump Tallital & EX TW Danth To Prop Sump Danth |
| 559 | Supply of Submersible pump and motor set: 300 L.P.M. discharge at (65-75) mts. NEH. |
| 560 | Supply of Submersible pump and motor set: 300 L.P.M. discharge at (65-75) mts. NEH. as spare. |
| 561 | Providing, Installation and commissioning of Power coated and CNC fabricated electric control panel upto 10 HP submersible pump set, 14 SWCG CRCA sheet thickness of energy saving variable frequency starter of 10 HP heavy duty which will operate submersible pump coomprises of which includes F-MCCB AMP, Spreader links, rotary handles, red, yellow, blue and Amber indicators, current transformers (CT's), multi function meter which will indicate PF, THD, current, voltage, KWH and KVar etc. MCB's, voltage protections devices, surge protection devices which will handle type I and type 2 surges, control transformers to provide proper phase and neutral to the control devices in panel, selector switches, input choke for 10 HP control contractors and main contactors at the output of VFD, terminal blocks, power and control wiring to the entire. |
| 562 | Automatic Power Factor Control panel (APFC) upto 10KVAR with monitoring power factor of electrical system using sensors and micro processores |
| 563 | Supply of of 06 sq.mm. 3 core Copper conductor P.V.C. insulated submersible cable |
| 564 | Supply of Earthing materials as per specification and site Requirment |
| 565 | Supply of Main piping and valves as per specification and site Requirment |
| 566 | SITC of AC based diaphram operated dual solenoid control valve sluice valve (2 Nos) for flow / presssure / level controlling with controller / RTU PN 10/16, Bonnet- DI (GGG-50), tubing SS304, capable to transmit / communicate data to MIS as well as local control room server of 80 mm dia delivery pipeline. |
| 567 | Supply of 20KVA automatic voltage regulator (compact) servo controlled stabilizer with accessories as per specification and site Requirement |
| 568 | Supply of chain pulley 3.0 tonne capacity with 4.5mt.lift . |
| 569 | Supply of Gauges as per specification |
| 570 | Supply of Rubber Insulation sheet 1mt. x 2mt.x 0.025 mtr. |
| 571 | Supply of 63 Amp. TPN Main Switch |
| 572 | Installation, commissioning and Testing of all pumping plant & Accessoriees complete |
| 573 | Painting of entire installation with 2 coats of super enamel paint as per direction of Engineer-In-Charge of works. |
| 574 | Fire exhtenguisher (6Kg) |
| 575 | Tools and Spanners – |
| 576 | Autophase reseval Unit (APR) Panel as per specifications. |
| 577 | Internal & external Electrification of Pump house |
| 578 | Intelligent GSM/Web/PLC based Mini Remote Terminal Units/PLC with analog and digital parameters and features as specified mini T.W. and transmit data on GSM backbone. GSM based wireless Communication system capable to transfer and gather data from remote sites to master Control Stations (Voltage, Current, Power factor, Pumping running Hour etc.) with 6 Amp. Automatic Voltage stabilizer including high and low cut and isolation transformer including Erection, testing and commissioining and modification of starter with AC and DC relays and necessary wiring complete in all respect. |
| 579 | Data commmunication gatway devices for data acquisition and communication to IOT based cloud server centralized system with stand protocol using wi-fi / GPRS ethernet for atteast 02 months data backup with all accessories. |
| 580 | Over voltage & under voltage trip protection (350 V-450 V) |
| 581 | IOT based intelligent Pressure transmitter capable to communicate / transmit data to MIS as well as local control room servor for tubewell |
| 582 | IOT based Electro magnetic flow meter of 80 mm size capable to communicate / transmit data to MIS as well as local control room servor for tubewell. |
| 583 | SITC of depth sensor for tubewell (upto 100 mt range) with non vented pressure sensor, sensor cable and necessary accessories complete as per technical specification hydrostatic level transmitter should be capable of transmitting data to SCADA system and portal. |
| 584 | Supply, installation, testing and commissioning of online Chlorine, pH and TDS measuring unit for water supply system, suitable for continuous monitoring of treated/raw water quality, complete with industrial-grade pH sensor and TDS sensor with necessary flow cell / immersion arrangement, automatic temperature compensation, digital transmitter and display unit.The system shall be operable on AC power supply as well as solar power with provision of solar panel, charge controllerand battery backup, ensuring uninterrupted operation. The unit shall be complete with control and communication module capable of transmitting real-time pH and TDS data, alarms and system status to the Monitoring & Control System (MCS) / SCADA through suitable communication protocol (RS-485 / GSM / NB-IoT / Ethernet as applicable). The system shall include enclosure of minimum IP-65 protection, mounting structure, signal and power cables, cable glands, earthing, software configuration, calibration, testing, commissioning and integration with MCS, complete in all respects as per tender document specifications. |
| 585 | CCTV camera with 2 MP, IP dome CCTV colour night vision, Dline 2 port POE switch full Giga, D link connector PVC box, complete wireless communication setup and 128 GB memory card. |
| 586 | UPS of suitable capacity for control supply of automation |
| 587 | SITC of ultrasonic type level transmitter for GLSR complete. |
| 588 | Signal cabling between RTU/PLC and field instruments including screened/unscreened & control copper cable, etc complete in all respect |
| 589 | S.I.T.C. of Submersible Pumping Plant with Accessories for Prop TW Danth To Prop Sump Danth |
| 590 | Supply of Submersible pump and motor set: 200 L.P.M. discharge at 100 mts. NEH. |
| 591 | Supply of Submersible pump and motor set: 200 L.P.M. discharge at100 mts. NEH. as spare. |
| 592 | Providing, Installation and commissioning of Power coated and CNC fabricated electric control panel upto 10 HP submersible pump set, 14 SWCG CRCA sheet thickness of energy saving variable frequency starter of 10 HP heavy duty which will operate submersible pump coomprises of which includes F-MCCB AMP, Spreader links, rotary handles, red, yellow, blue and Amber indicators, current transformers (CT's), multi function meter which will indicate PF, THD, current, voltage, KWH and KVar etc. MCB's, voltage protections devices, surge protection devices which will handle type I and type 2 surges, control transformers to provide proper phase and neutral to the control devices in panel, selector switches, input choke for 10 HP control contractors and main contactors at the output of VFD, terminal blocks, power and control wiring to the entire. |
| 593 | Automatic Power Factor Control panel (APFC) upto 10KVAR with monitoring power factor of electrical system using sensors and micro processores |
| 594 | Supply of of 06 sq.mm. 3 core Copper conductor P.V.C. insulated submersible cable |
| 595 | Supply of Earthing materials as per specification and site Requirment |
| 596 | Supply of Main piping and valves as per specification and site Requirment |
| 597 | SITC of AC based diaphram operated dual solenoid control valve sluice valve (2 Nos) for flow / presssure / level controlling with controller / RTU PN 10/16, Bonnet- DI (GGG-50), tubing SS304, capable to transmit / communicate data to MIS as well as local control room server of 80 mm dia delivery pipeline. |
| 598 | Supply of 20KVA automatic voltage regulator (compact) servo controlled stabilizer with accessories as per specification and site Requirement |
| 599 | Supply of chain pulley 3.0 tonne capacity with 4.5mt.lift . |
| 600 | Supply of Gauges as per specification |
| 601 | Supply of Rubber Insulation sheet 1mt. x 2mt.x 0.025 mtr. |
| 602 | Supply of 63 Amp. TPN Main Switch |
| 603 | Installation, commissioning and Testing of all pumping plant & Accessoriees complete |
| 604 | Painting of entire installation with 2 coats of super enamel paint as per direction of Engineer-In-Charge of works. |
| 605 | Fire exhtenguisher (6Kg) |
| 606 | Tools and Spanners – |
| 607 | Autophase reseval Unit (APR) Panel as per specifications. |
| 608 | Internal & external Electrification of Pump house |
| 609 | Intelligent GSM/Web/PLC based Mini Remote Terminal Units/PLC with analog and digital parameters and features as specified mini T.W. and transmit data on GSM backbone. GSM based wireless Communication system capable to transfer and gather data from remote sites to master Control Stations (Voltage, Current, Power factor, Pumping running Hour etc.) with 6 Amp. Automatic Voltage stabilizer including high and low cut and isolation transformer including Erection, testing and commissioining and modification of starter with AC and DC relays and necessary wiring complete in all respect. |
| 610 | Data commmunication gateway devices for data acquisition and communication to IOT based cloud server centralized system with stand protocol using wi-fi / GPRS ethernet for atteast 02 months data backup with all accessories. |
| 611 | Over voltage & under voltage trip protection (350 V-450 V) |
| 612 | IOT based intelligent Pressure transmitter capable to communicate / transmit data to MIS as well as local control room servor for tubewell |
| 613 | IOT based Electro magnetic flow meter of 80 mm size capable to communicate / transmit data to MIS as well as local control room servor for tubewell. |
| 614 | SITC of depth sensor for tubewell (upto 100 mt range) with non vented pressure sensor, sensor cable and necessary accessories complete as per technical specification hydrostatic level transmitter should be capable of transmitting data to SCADA system and portal. |
| 615 | Supply, installation, testing and commissioning of online Chlorine, pH and TDS measuring unit for water supply system, suitable for continuous monitoring of treated/raw water quality, complete with industrial-grade pH sensor and TDS sensor with necessary flow cell / immersion arrangement, automatic temperature compensation, digital transmitter and display unit.The system shall be operable on AC power supply as well as solar power with provision of solar panel, charge controllerand battery backup, ensuring uninterrupted operation. The unit shall be complete with control and communication module capable of transmitting real-time pH and TDS data, alarms and system status to the Monitoring & Control System (MCS) / SCADA through suitable communication protocol (RS-485 / GSM / NB-IoT / Ethernet as applicable). The system shall include enclosure of minimum IP-65 protection, mounting structure, signal and power cables, cable glands, earthing, software configuration, calibration, testing, commissioning and integration with MCS, complete in all respects as per tender document specifications. |
| 616 | CCTV camera with 2 MP, IP dome CCTV colour night vision, Dline 2 port POE switch full Giga, D link connector PVC box, complete wireless communication setup and 128 GB memory card. |
| 617 | UPS of suitable capacity for control supply of automation |
| 618 | SITC of ultrasonic type level transmitter for GLSR complete. |
| 619 | Signal cabling between RTU/PLC and field instruments including screened/unscreened & control copper cable, etc complete in all respect |
| 620 | S.I.T.C. of Submersible Pumping Plant with Accessories for Ex TW Naul To Prop Sump Naul |
| 621 | Supply of Submersible pump and motor set: 210 L.P.M. discharge at 110 mts. NEH. |
| 622 | Supply of Submersible pump and motor set: 210 L.P.M. discharge at 110 mts. NEH. as spare. |
| 623 | Providing, Installation and commissioning of Power coated and CNC fabricated electric control panel upto 10 HP submersible pump set, 14 SWCG CRCA sheet thickness of energy saving variable frequency starter of 10 HP heavy duty which will operate submersible pump coomprises of which includes F-MCCB AMP, Spreader links, rotary handles, red, yellow, blue and Amber indicators, current transformers (CT's), multi function meter which will indicate PF, THD, current, voltage, KWH and KVar etc. MCB's, voltage protections devices, surge protection devices which will handle type I and type 2 surges, control transformers to provide proper phase and neutral to the control devices in panel, selector switches, input choke for 10 HP control contractors and main contactors at the output of VFD, terminal blocks, power and control wiring to the entire. |
| 624 | Automatic Power Factor Control panel (APFC) upto 10KVAR with monitoring power factor of electrical system using sensors and micro processores |
| 625 | Supply of of 06 sq.mm. 3 core Copper conductor P.V.C. insulated submersible cable |
| 626 | Supply of Earthing materials as per specification and site Requirment |
| 627 | Supply of Main piping and valves as per specification and site Requirment |
| 628 | SITC of AC based diaphram operated dual solenoid control valve sluice valve (2 Nos) for flow / presssure / level controlling with controller / RTU PN 10/16, Bonnet- DI (GGG-50), tubing SS304, capable to transmit / communicate data to MIS as well as local control room server of 80 mm dia delivery pipeline. |
| 629 | Supply of 20KVA automatic voltage regulator (compact) servo controlled stabilizer with accessories as per specification and site Requirement |
| 630 | Supply of chain pulley 3.0 tonne capacity with 4.5mt.lift . |
| 631 | Supply of Gauges as per specification |
| 632 | Supply of Rubber Insulation sheet 1mt. x 2mt.x 0.025 mtr. |
| 633 | Supply of 63 Amp. TPN Main Switch |
| 634 | Installation, commissioning and Testing of all pumping plant & Accessoriees complete |
| 635 | Painting of entire installation with 2 coats of super enamel paint as per direction of Engineer-In-Charge of works. |
| 636 | Fire exhtenguisher (6Kg) |
| 637 | Tools and Spanners – |
| 638 | Autophase reseval Unit (APR) Panel as per specifications. |
| 639 | Internal & external Electrification of Pump house |
| 640 | Intelligent GSM/Web/PLC based Mini Remote Terminal Units/PLC with analog and digital parameters and features as specified mini T.W. and transmit data on GSM backbone. GSM based wireless Communication system capable to transfer and gather data from remote sites to master Control Stations (Voltage, Current, Power factor, Pumping running Hour etc.) with 6 Amp. Automatic Voltage stabilizer including high and low cut and isolation transformer including Erection, testing and commissioining and modification of starter with AC and DC relays and necessary wiring complete in all respect. |
| 641 | Data commmunication gatway devices for data acquisition and communication to IOT based cloud server centralized system with stand protocol using wi-fi / GPRS ethernet for atteast 02 months data backup with all accessories. |
| 642 | Over voltage & under voltage trip protection (350 V-450 V) |
| 643 | IOT based intelligent Pressure transmitter capable to communicate / transmit data to MIS as well as local control room servor for tubewell |
| 644 | IOT based Electro magnetic flow meter of 80 mm size capable to communicate / transmit data to MIS as well as local control room servor for tubewell. |
| 645 | SITC of depth sensor for tubewell (upto 100 mt range) with non vented pressure sensor, sensor cable and necessary accessories complete as per technical specification hydrostatic level transmitter should be capable of transmitting data to SCADA system and portal. |
| 646 | Supply, installation, testing and commissioning of online Chlorine, pH and TDS measuring unit for water supply system, suitable for continuous monitoring of treated/raw water quality, complete with industrial-grade pH sensor and TDS sensor with necessary flow cell / immersion arrangement, automatic temperature compensation, digital transmitter and display unit.The system shall be operable on AC power supply as well as solar power with provision of solar panel, charge controllerand battery backup, ensuring uninterrupted operation. The unit shall be complete with control and communication module capable of transmitting real-time pH and TDS data, alarms and system status to the Monitoring & Control System (MCS) / SCADA through suitable communication protocol (RS-485 / GSM / NB-IoT / Ethernet as applicable). The system shall include enclosure of minimum IP-65 protection, mounting structure, signal and power cables, cable glands, earthing, software configuration, calibration, testing, commissioning and integration with MCS, complete in all respects as per tender document specifications. |
| 647 | CCTV camera with 2 MP, IP dome CCTV colour night vision, Dline 2 port POE switch full Giga, D link connector PVC box, complete wireless communication setup and 128 GB memory card. |
| 648 | UPS of suitable capacity for control supply of automation |
| 649 | SITC of ultrasonic type level transmitter for GLSR complete. |
| 650 | Signal cabling between RTU/PLC and field instruments including screened/unscreened & control copper cable, etc complete in all respect |
| 651 | S.I.T.C. of Submersible Pumping Plant with Accessories for Ex Tw Jijhari To Prop Sump Jijhari |
| 652 | Supply of Submersible pump and motor set: 150 L.P.M. discharge at 70 mts. NEH. |
| 653 | Supply of Submersible pump and motor set: 150 L.P.M. discharge at70 mts. NEH. as spare. |
| 654 | Providing, Installation and commissioning of Power coated and CNC fabricated electric control panel upto 5 HP submersible pump set, 14 SWCG CRCA sheet thickness of energy saving variable frequency starter of 5 HP heavy duty which will operate submersible pump coomprises of which includes F-MCCB AMP, Spreader links, rotary handles, red, yellow, blue and Amber indicators, current transformers (CT's), multi function meter which will indicate PF, THD, current, voltage, KWH and KVar etc. MCB's, voltage protections devices, surge protection devices which will handle type I and type 2 surges, control transformers to provide proper phase and neutral to the control devices in panel, selector switches, input choke for 5 HP control contractors and main contactors at the output of VFD, terminal blocks, power and control wiring to the entire. |
| 655 | Automatic Power Factor Control panel (APFC) upto 5KVAR with monitoring power factor of electrical system using sensors and micro processores |
| 656 | Supply of of 06 sq.mm. 3 core Copper conductor P.V.C. insulated submersible cable |
| 657 | Supply of Earthing materials as per specification and site Requirment |
| 658 | Supply of Main piping and valves as per specification and site Requirment |
| 659 | SITC of AC based diaphram operated dual solenoid control valve sluice valve (2 Nos) for flow / presssure / level controlling with controller / RTU PN 10/16, Bonnet- DI (GGG-50), tubing SS304, capable to transmit / communicate data to MIS as well as local control room server of 80 mm dia delivery pipeline. |
| 660 | Supply of 10KVA automatic voltage regulator (compact) servo controlled stabilizer with accessories as per specification and site Requirement |
| 661 | Supply of chain pulley 3.0 tonne capacity with 4.5mt.lift . |
| 662 | Supply of Gauges as per specification |
| 663 | Supply of Rubber Insulation sheet 1mt. x 2mt.x 0.025 mtr. |
| 664 | Supply of 63 Amp. TPN Main Switch |
| 665 | Installation, commissioning and Testing of all pumping plant & Accessoriees complete |
| 666 | Painting of entire installation with 2 coats of super enamel paint as per direction of Engineer-In-Charge of works. |
| 667 | Fire exhtenguisher (6Kg) |
| 668 | Tools and Spanners – |
| 669 | Autophase reseval Unit (APR) Panel as per specifications. |
| 670 | Internal & external Electrification of Pump house |
| 671 | Intelligent GSM/Web/PLC based Mini Remote Terminal Units/PLC with analog and digital parameters and features as specified mini T.W. and transmit data on GSM backbone. GSM based wireless Communication system capable to transfer and gather data from remote sites to master Control Stations (Voltage, Current, Power factor, Pumping running Hour etc.) with 6 Amp. Automatic Voltage stabilizer including high and low cut and isolation transformer including Erection, testing and commissioining and modification of starter with AC and DC relays and necessary wiring complete in all respect. |
| 672 | Data commmunication gatway devices for data acquisition and communication to IOT based cloud server centralized system with stand protocol using wi-fi / GPRS ethernet for atteast 02 months data backup with all accessories. |
| 673 | Over voltage & under voltage trip protection (350 V-450 V) |
| 674 | IOT based intelligent Pressure transmitter capable to communicate / transmit data to MIS as well as local control room servor for tubewell |
| 675 | IOT based Electro magnetic flow meter of 80 mm size capable to communicate / transmit data to MIS as well as local control room servor for tubewell. |
| 676 | SITC of depth sensor for tubewell (upto 100 mt range) with non vented pressure sensor, sensor cable and necessary accessories complete as per technical specification hydrostatic level transmitter should be capable of transmitting data to SCADA system and portal. |
| 677 | Supply, installation, testing and commissioning of online Chlorine, pH and TDS measuring unit for water supply system, suitable for continuous monitoring of treated/raw water quality, complete with industrial-grade pH sensor and TDS sensor with necessary flow cell / immersion arrangement, automatic temperature compensation, digital transmitter and display unit.The system shall be operable on AC power supply as well as solar power with provision of solar panel, charge controllerand battery backup, ensuring uninterrupted operation. The unit shall be complete with control and communication module capable of transmitting real-time pH and TDS data, alarms and system status to the Monitoring & Control System (MCS) / SCADA through suitable communication protocol (RS-485 / GSM / NB-IoT / Ethernet as applicable). The system shall include enclosure of minimum IP-65 protection, mounting structure, signal and power cables, cable glands, earthing, software configuration, calibration, testing, commissioning and integration with MCS, complete in all respects as per tender document specifications. |
| 678 | CCTV camera with 2 MP, IP dome CCTV colour night vision, Dline 2 port POE switch full Giga, D link connector PVC box, complete wireless communication setup and 128 GB memory card. |
| 679 | UPS of suitable capacity for control supply of automation |
| 680 | SITC of ultrasonic type level transmitter for GLSR complete. |
| 681 | Signal cabling between RTU/PLC and field instruments including screened/unscreened & control copper cable, etc complete in all respect |
| 682 | S.I.T.C. of Submersible Pumping Plant with Accessories for Pro TW Chunauti To Pro Sump Chunauti |
| 683 | Supply of Submersible pump and motor set: 100 L.P.M. discharge at 110 mts. NEH. |
| 684 | Supply of Submersible pump and motor set: 100 L.P.M. discharge at 110 mts. NEH. as spare. |
| 685 | Providing, Installation and commissioning of Power coated and CNC fabricated electric control panel upto 5 HP submersible pump set, 14 SWCG CRCA sheet thickness of energy saving variable frequency starter of 5 HP heavy duty which will operate submersible pump coomprises of which includes F-MCCB AMP, Spreader links, rotary handles, red, yellow, blue and Amber indicators, current transformers (CT's), multi function meter which will indicate PF, THD, current, voltage, KWH and KVar etc. MCB's, voltage protections devices, surge protection devices which will handle type I and type 2 surges, control transformers to provide proper phase and neutral to the control devices in panel, selector switches, input choke for 5 HP control contractors and main contactors at the output of VFD, terminal blocks, power and control wiring to the entire. |
| 686 | Automatic Power Factor Control panel (APFC) upto 5KVAR with monitoring power factor of electrical system using sensors and micro processores |
| 687 | Supply of of 06 sq.mm. 3 core Copper conductor P.V.C. insulated submersible cable |
| 688 | Supply of Earthing materials as per specification and site Requirment |
| 689 | Supply of Main piping and valves as per specification and site Requirment |
| 690 | SITC of AC based diaphram operated dual solenoid control valve sluice valve (2 Nos) for flow / presssure / level controlling with controller / RTU PN 10/16, Bonnet- DI (GGG-50), tubing SS304, capable to transmit / communicate data to MIS as well as local control room server of 80 mm dia delivery pipeline. |
| 691 | Supply of 10KVA automatic voltage regulator (compact) servo controlled stabilizer with accessories as per specification and site Requirement |
| 692 | Supply of chain pulley 3.0 tonne capacity with 4.5mt.lift . |
| 693 | Supply of Gauges as per specification |
| 694 | Supply of Rubber Insulation sheet 1mt. x 2mt.x 0.025 mtr. |
| 695 | Supply of 63 Amp. TPN Main Switch |
| 696 | Installation, commissioning and Testing of all pumping plant & Accessoriees complete |
| 697 | Painting of entire installation with 2 coats of super enamel paint as per direction of Engineer-In-Charge of works. |
| 698 | Fire exhtenguisher (6Kg) |
| 699 | Tools and Spanners – |
| 700 | Autophase reseval Unit (APR) Panel as per specifications. |
| 701 | Internal & external Electrification of Pump house |
| 702 | Intelligent GSM/Web/PLC based Mini Remote Terminal Units/PLC with analog and digital parameters and features as specified mini T.W. and transmit data on GSM backbone. GSM based wireless Communication system capable to transfer and gather data from remote sites to master Control Stations (Voltage, Current, Power factor, Pumping running Hour etc.) with 6 Amp. Automatic Voltage stabilizer including high and low cut and isolation transformer including Erection, testing and commissioining and modification of starter with AC and DC relays and necessary wiring complete in all respect. |
| 703 | Data commmunication gatway devices for data acquisition and communication to IOT based cloud server centralized system with stand protocol using wi-fi / GPRS ethernet for atteast 02 months data backup with all accessories. |
| 704 | Over voltage & under voltage trip protection (350 V-450 V) |
| 705 | IOT based intelligent Pressure transmitter capable to communicate / transmit data to MIS as well as local control room servor for tubewell |
| 706 | IOT based Electro magnetic flow meter of 80 mm size capable to communicate / transmit data to MIS as well as local control room servor for tubewell. |
| 707 | SITC of depth sensor for tubewell (upto 100 mt range) with non vented pressure sensor, sensor cable and necessary accessories complete as per technical specification hydrostatic level transmitter should be capable of transmitting data to SCADA system and portal. |
| 708 | Supply, installation, testing and commissioning of online Chlorine, pH and TDS measuring unit for water supply system, suitable for continuous monitoring of treated/raw water quality, complete with industrial-grade pH sensor and TDS sensor with necessary flow cell / immersion arrangement, automatic temperature compensation, digital transmitter and display unit.The system shall be operable on AC power supply as well as solar power with provision of solar panel, charge controllerand battery backup, ensuring uninterrupted operation. The unit shall be complete with control and communication module capable of transmitting real-time pH and TDS data, alarms and system status to the Monitoring & Control System (MCS) / SCADA through suitable communication protocol (RS-485 / GSM / NB-IoT / Ethernet as applicable). The system shall include enclosure of minimum IP-65 protection, mounting structure, signal and power cables, cable glands, earthing, software configuration, calibration, testing, commissioning and integration with MCS, complete in all respects as per tender document specifications. |
| 709 | CCTV camera with 2 MP, IP dome CCTV colour night vision, Dline 2 port POE switch full Giga, D link connector PVC box, complete wireless communication setup and 128 GB memory card. |
| 710 | UPS of suitable capacity for control supply of automation |
| 711 | SITC of ultrasonic type level transmitter for GLSR complete. |
| 712 | Signal cabling between RTU/PLC and field instruments including screened/unscreened & control copper cable, etc complete in all respect |
| 713 | Centrifugal Prop Sump Naldamyanti Lake To Prop CWR Mehra Gaon-1Pumping Plant (Centrifugal) |
| 714 | SITC of centrifugal pump set capable of delivering 550 LPM discharge , 210 Mtr. complete with motor, base plate, coupling and coupling guards 2900 RPM |
| 715 | Supply of Oil cooled fully Automatic ATS Star Delta starter as per specification for above pumping plant. |
| 716 | Control panel with one no. incoming & 2nos. Outgoing as per specification. |
| 717 | Power wiring and earthing material as per specification and site requirement |
| 718 | Main piping and Valves |
| 719 | SITC of AC based diaphram operated dual solenoid control valve sluice valve (2 Nos) for flow / presssure / level controlling with controller / RTU PN 10/16, Bonnet- DI (GGG-50), tubing SS304, capable to transmit / communicate data to MIS as well as local control room server of 100 mm dia delivery pipeline. |
| 720 | Supply of pressure gauge & compound gauge with control cook air line fitting requirement. |
| 721 | Tools |
| 722 | Rubber Resistance Sheet 1Mt.x 2Mt x.025Mt. |
| 723 | Installation,commissioning & testing of pumping plant at site |
| 724 | Painting of above pumping plants with 2 coat of enamel paint. |
| 725 | Testing of pump set |
| 726 | (i) At Work |
| 727 | (ii) At Site |
| 728 | Carting of 2 sets of pumping plant with all material i.e.pumps motors, starters panel, pipe and special valves etc, from deptt. store haldwani to site |
| 729 | Prop Sump Naldamyanti Lake To Prop CWR Mehra Gaon-2 Pumping Plant (Centrifugal) |
| 730 | SITC of centrifugal pump set capable of delivering 550 LPM discharge , 280 Mtr. complete with motor, base plate, coupling and coupling guards 2900 RPM |
| 731 | Supply of Oil cooled fully Automatic ATS Star Delta starter as per specification for above pumping plant. |
| 732 | Control panel with one no. incoming & 2nos. Outgoing as per specification. |
| 733 | Power wiring and earthing material as per specification and site requirement |
| 734 | Main piping and Valves |
| 735 | SITC of AC based diaphram operated dual solenoid control valve sluice valve (2 Nos) for flow / presssure / level controlling with controller / RTU PN 10/16, Bonnet- DI (GGG-50), tubing SS304, capable to transmit / communicate data to MIS as well as local control room server of 100 mm dia delivery pipeline. |
| 736 | Supply of pressure gauge & compound gauge with control cook air line fitting requirement. |
| 737 | Tools |
| 738 | Rubber Resistance Sheet 1Mt.x 2Mt x.025Mt. |
| 739 | Servo Control Voltage Stabilizer 300KVA suitable for regulating incoming voltage 300 to 480Volt , outgoing voltage 415Volt with suitable size of change over switch and copper cable, first filling of Transformer Oil and complete installation. |
| 740 | 400 Amp TPN main switch |
| 741 | H.O.T Crane including Travelling Trolly, Rail, 5.0 Ton capacity lift upto 6.0 Mtr with chainpully block complete |
| 742 | Internal & external Electrification of Pump house |
| 743 | Automatic Power Factor Control panel (APFC) upto 75 KVAR with monitoring power factor of electrical system using sensors and micro processores |
| 744 | Autophase reseval Unit (APR) Panel |
| 745 | Installation,commissioning & testing of pumping plant at site |
| 746 | Painting of above pumping plants with 2 coat of enamel paint. |
| 747 | Testing of pump set |
| 748 | (i) At Work |
| 749 | (ii) At Site |
| 750 | Carting of 2 sets of pumping plant with all material i.e.pumps motors, starters panel, pipe and special valves etc, from deptt. store haldwani to site |
| 751 | Insurances, Freight from works to store, of pump set. |
| 752 | Intelligent GSM/Web/PLC based Mini Remote Terminal Units/PLC with analog and digital parameters and features as specified mini T.W. and transmit data on GSM backbone. GSM based wireless Communication system capable to transfer and gather data from remote sites to master Control Stations (Voltage, Current, Power factor, Pumping running Hour etc.) with 6 Amp. Automatic Voltage stabilizer including high and low cut and isolation transformer including Erection, testing and commissioining and modification of starter with AC and DC relays and necessary wiring complete in all respect. |
| 753 | S/F of data commmunication gatway devices for data acquisition and communication gateway devices for data acquisition and communication to IOT based cloud server centralized system with stand protocol using wi-fi / GPRS ethernet for atteast 02 months data backup with all accessories. |
| 754 | Over voltage & under voltage trip protection (350 V-450 V) |
| 755 | IOT based intelligent Pressure transmitter capable to communicate / transmit data to MIS as well as local control room servor for tubewell |
| 756 | IOT based Electro magnetic flow meter of 100 mm size capable to communicate / transmit data to MIS as well as local control room servor for tubewell. |
| 757 | IOT based Energy meter |
| 758 | IOT based Actuator panels |
| 759 | Signal cabling between RTU/PLC and field instruments including screened/unscreened & control copper cable, etc complete in all respect |
| 760 | Prop. Sump Sattal to Prop. CWR Bhagtura Pumping Plant (Centrifugal) |
| 761 | SITC of centrifugal pump set capable of delivering 400 LPM discharge , 310 Mtr. complete with motor, base plate, coupling and coupling guards 2900 RPM |
| 762 | Supply of Oil cooled fully Automatic ATS Star Delta starter as per specification for above pumping plant. |
| 763 | Control panel with one no. incoming & 2nos. Outgoing as per specification. |
| 764 | Power wiring and earthing material as per specification and site requirement |
| 765 | Main piping and Valves |
| 766 | SITC of AC based diaphram operated dual solenoid control valve sluice valve (2 Nos) for flow / presssure / level controlling with controller / RTU PN 10/16, Bonnet- DI (GGG-50), tubing SS304, capable to transmit / communicate data to MIS as well as local control room server of 100 mm dia delivery pipeline. |
| 767 | Supply of pressure gauge & compound gauge with control cook air line fitting requirement. |
| 768 | Tools |
| 769 | Rubber Resistance Sheet 1Mt.x 2Mt x.025Mt. |
| 770 | Servo Control Voltage Stabilizer 150 KVA suitable for regulating incoming voltage 300 to 480Volt , outgoing voltage 415Volt with suitable size of change over switch and copper cable, first filling of Transformer Oil and complete installation. |
| 771 | 200 Amp TPN main switch |
| 772 | H.O.T Crane including Travelling Trolly, Rail, 5.0 Ton capacity lift upto 6.0 Mtr with chainpully block complete |
| 773 | Internal & external Electrification of Pump house |
| 774 | Automatic Power Factor Control panel (APFC) upto 25 KVAR with monitoring power factor of electrical system using sensors and micro processores |
| 775 | Autophase reseval Unit (APR) Panel |
| 776 | Installation,commissioning & testing of pumping plant at site |
| 777 | Painting of above pumping plants with 2 coat of enamel paint. |
| 778 | Testing of pump set |
| 779 | (i) At Work |
| 780 | (ii) At Site |
| 781 | Carting of 2 sets of pumping plant with all material i.e.pumps motors, starters panel, pipe and special valves etc, from deptt. store haldwani to site |
| 782 | Intelligent GSM/Web/PLC based Mini Remote Terminal Units/PLC with analog and digital parameters and features as specified mini T.W. and transmit data on GSM backbone. GSM based wireless Communication system capable to transfer and gather data from remote sites to master Control Stations (Voltage, Current, Power factor, Pumping running Hour etc.) with 6 Amp. Automatic Voltage stabilizer including high and low cut and isolation transformer including Erection, testing and commissioining and modification of starter with AC and DC relays and necessary wiring complete in all respect. |
| 783 | S/F of data commmunication gatway devices for data acquisition and communication gateway devices for data acquisition and communication to IOT based cloud server centralized system with stand protocol using wi-fi / GPRS ethernet for atteast 02 months data backup with all accessories. |
| 784 | Over voltage & under voltage trip protection (350 V-450 V) |
| 785 | IOT based intelligent Pressure transmitter capable to communicate / transmit data to MIS as well as local control room servor for tubewell |
| 786 | IOT based Electro magnetic flow meter of 100 mm size capable to communicate / transmit data to MIS as well as local control room servor for tubewell. |
| 787 | IOT based Energy meter |
| 788 | IOT based Actuator panels |
| 789 | Signal cabling between RTU/PLC and field instruments including screened/unscreened & control copper cable, etc complete in all respect |
| 790 | Prop. Sump Block Office to Prop CWR Khutani Pumping Plant (Centrifugal) |
| 791 | SITC of centrifugal pump set capable of delivering 350 LPM discharge , 220 Mtr. complete with motor, base plate, coupling and coupling guards 2900 RPM |
| 792 | Supply of Oil cooled fully Automatic ATS Star Delta starter as per specification for above pumping plant. |
| 793 | Control panel with one no. incoming & 2nos. Outgoing as per specification. |
| 794 | Power wiring and earthing material as per specification and site requirement |
| 795 | Main piping and Valves |
| 796 | SITC of AC based diaphram operated dual solenoid control valve sluice valve (2 Nos) for flow / presssure / level controlling with controller / RTU PN 10/16, Bonnet- DI (GGG-50), tubing SS304, capable to transmit / communicate data to MIS as well as local control room server of 80mm dia delivery pipeline. |
| 797 | Supply of pressure gauge & compound gauge with control cook air line fitting requirement. |
| 798 | Tools |
| 799 | Rubber Resistance Sheet 1Mt.x 2Mt x.025Mt. |
| 800 | Installation,commissioning & testing of pumping plant at site |
| 801 | Painting of above pumping plants with 2 coat of enamel paint. |
| 802 | Testing of pump set |
| 803 | (i) At Work |
| 804 | (ii) At Site |
| 805 | Carting of 2 sets of pumping plant with all material i.e.pumps motors, starters panel, pipe and special valves etc, from deptt. store haldwani to site |
| 806 | Prop. Sump Block Office to Ex. OHT Vikas Bhawan (Staging 15M) Pumping Plant (Centrifugal) |
| 807 | SITC of centrifugal pump set capable of delivering 200 LPM discharge , 75 Mtr. complete with motor, base plate, coupling and coupling guards 2900 RPM |
| 808 | Supply of Oil cooled fully Automatic ATS Star Delta starter as per specification for above pumping plant. |
| 809 | Control panel with one no. incoming & 2nos. Outgoing as per specification. |
| 810 | Power wiring and earthing material as per specification and site requirement |
| 811 | Main piping and Valves |
| 812 | SITC of AC based diaphram operated dual solenoid control valve sluice valve (2 Nos) for flow / presssure / level controlling with controller / RTU PN 10/16, Bonnet- DI (GGG-50), tubing SS304, capable to transmit / communicate data to MIS as well as local control room server of 80mm dia delivery pipeline. |
| 813 | Supply of pressure gauge & compound gauge with control cook air line fitting requirement. |
| 814 | Tools |
| 815 | Rubber Resistance Sheet 1Mt.x 2Mt x.025Mt. |
| 816 | Installation,commissioning & testing of pumping plant at site |
| 817 | Painting of above pumping plants with 2 coat of enamel paint. |
| 818 | Testing of pump set |
| 819 | (i) At Work |
| 820 | (ii) At Site |
| 821 | Carting of 2 sets of pumping plant with all material i.e.pumps motors, starters panel, pipe and special valves etc, from deptt. store haldwani to site |
| 822 | Prop. Sump Block Office to Ex. CWR Soan Gaon Pumping Plant (Centrifugal) |
| 823 | SITC of centrifugal pump set capable of delivering 600 LPM discharge , 150 Mtr. complete with motor, base plate, coupling and coupling guards 2900 RPM |
| 824 | Supply of Oil cooled fully Automatic ATS Star Delta starter as per specification for above pumping plant. |
| 825 | Control panel with one no. incoming & 2nos. Outgoing as per specification. |
| 826 | Power wiring and earthing material as per specification and site requirement |
| 827 | Main piping and Valves |
| 828 | SITC of AC based diaphram operated dual solenoid control valve sluice valve (2 Nos) for flow / presssure / level controlling with controller / RTU PN 10/16, Bonnet- DI (GGG-50), tubing SS304, capable to transmit / communicate data to MIS as well as local control room server of 100 mm dia delivery pipeline. |
| 829 | Supply of pressure gauge & compound gauge with control cook air line fitting requirement. |
| 830 | Tools |
| 831 | Rubber Resistance Sheet 1Mt.x 2Mt x.025Mt. |
| 832 | Servo Control Voltage Stabilizer 200 KVA suitable for regulating incoming voltage 300 to 480Volt , outgoing voltage 415Volt with suitable size of change over switch and copper cable, first filling of Transformer Oil and complete installation. |
| 833 | 400 Amp TPN main switch |
| 834 | H.O.T Crane including Travelling Trolly, Rail, 5.0 Ton capacity lift upto 6.0 Mtr with chainpully block complete |
| 835 | Internal & external Electrification of Pump house |
| 836 | Automatic Power Factor Control panel (APFC) upto 45 KVAR with monitoring power factor of electrical system using sensors and micro processores |
| 837 | Autophase reseval Unit (APR) Panel |
| 838 | Installation,commissioning & testing of pumping plant at site |
| 839 | Painting of above pumping plants with 2 coat of enamel paint. |
| 840 | Testing of pump set |
| 841 | (i) At Work |
| 842 | (ii) At Site |
| 843 | Carting of 2 sets of pumping plant with all material i.e.pumps motors, starters panel, pipe and special valves etc, from deptt. store haldwani to site |
| 844 | Intelligent GSM/Web/PLC based Mini Remote Terminal Units/PLC with analog and digital parameters and features as specified mini T.W. and transmit data on GSM backbone. GSM based wireless Communication system capable to transfer and gather data from remote sites to master Control Stations (Voltage, Current, Power factor, Pumping running Hour etc.) with 6 Amp. Automatic Voltage stabilizer including high and low cut and isolation transformer including Erection, testing and commissioining and modification of starter with AC and DC relays and necessary wiring complete in all respect. |
| 845 | S/F of data commmunication gatway devices for data acquisition and communication gateway devices for data acquisition and communication to IOT based cloud server centralized system with stand protocol using wi-fi / GPRS ethernet for atteast 02 months data backup with all accessories. |
| 846 | Over voltage & under voltage trip protection (350 V-450 V) |
| 847 | IOT based intelligent Pressure transmitter capable to communicate / transmit data to MIS as well as local control room servor for tubewell |
| 848 | IOT based Electro magnetic flow meter of 80/100 mm size capable to communicate / transmit data to MIS as well as local control room servor for tubewell. |
| 849 | IOT based Energy meter |
| 850 | IOT based Actuator panels |
| 851 | Signal cabling between RTU/PLC and field instruments including screened/unscreened & control copper cable, etc complete in all respect |
| 852 | Prop. Sump Jijhari to Ex. CWR Thalla Pumping Plant (Centrifugal) |
| 853 | SITC of centrifugal pump set capable of delivering 700 LPM discharge , 300 Mtr. complete with motor, base plate, coupling and coupling guards 2900 RPM |
| 854 | Supply of Oil cooled fully Automatic ATS Star Delta starter as per specification for above pumping plant. |
| 855 | Control panel with one no. incoming & 2nos. Outgoing as per specification. |
| 856 | Power wiring and earthing material as per specification and site requirement |
| 857 | Main piping and Valves |
| 858 | SITC of AC based diaphram operated dual solenoid control valve sluice valve (2 Nos) for flow / presssure / level controlling with controller / RTU PN 10/16, Bonnet- DI (GGG-50), tubing SS304, capable to transmit / communicate data to MIS as well as local control room server of 100 mm dia delivery pipeline. |
| 859 | Supply of pressure gauge & compound gauge with control cook air line fitting requirement. |
| 860 | Tools |
| 861 | Rubber Resistance Sheet 1Mt.x 2Mt x.025Mt. |
| 862 | Servo Control Voltage Stabilizer 250 KVA suitable for regulating incoming voltage 300 to 480Volt , outgoing voltage 415Volt with suitable size of change over switch and copper cable, first filling of Transformer Oil and complete installation. |
| 863 | 400 Amp TPN main switch |
| 864 | H.O.T Crane including Travelling Trolly, Rail, 5.0 Ton capacity lift upto 6.0 Mtr with chainpully block complete |
| 865 | Internal & external Electrification of Pump house |
| 866 | Automatic Power Factor Control panel (APFC) upto 45 KVAR with monitoring power factor of electrical system using sensors and micro processores |
| 867 | Autophase reseval Unit (APR) Panel |
| 868 | Installation,commissioning & testing of pumping plant at site |
| 869 | Painting of above pumping plants with 2 coat of enamel paint. |
| 870 | Testing of pump set |
| 871 | (i) At Work |
| 872 | (ii) At Site |
| 873 | Carting of 2 sets of pumping plant with all material i.e.pumps motors, starters panel, pipe and special valves etc, from deptt. store haldwani to site |
| 874 | Intelligent GSM/Web/PLC based Mini Remote Terminal Units/PLC with analog and digital parameters and features as specified mini T.W. and transmit data on GSM backbone. GSM based wireless Communication system capable to transfer and gather data from remote sites to master Control Stations (Voltage, Current, Power factor, Pumping running Hour etc.) with 6 Amp. Automatic Voltage stabilizer including high and low cut and isolation transformer including Erection, testing and commissioining and modification of starter with AC and DC relays and necessary wiring complete in all respect. |
| 875 | S/F of data commmunication gatway devices for data acquisition and communication gateway devices for data acquisition and communication to IOT based cloud server centralized system with stand protocol using wi-fi / GPRS ethernet for atteast 02 months data backup with all accessories. |
| 876 | Over voltage & under voltage trip protection (350 V-450 V) |
| 877 | IOT based intelligent Pressure transmitter capable to communicate / transmit data to MIS as well as local control room servor for tubewell |
| 878 | IOT based Electro magnetic flow meter of 100 mm size capable to communicate / transmit data to MIS as well as local control room servor for tubewell. |
| 879 | IOT based Energy meter |
| 880 | IOT based Actuator panels |
| 881 | Signal cabling between RTU/PLC and field instruments including screened/unscreened & control copper cable, etc complete in all respect |
| 882 | Prop. Tallital to Ex. CWR Sangadi Gaon Pumping Plant (Centrifugal) |
| 883 | SITC of centrifugal pump set capable of delivering 500 LPM discharge , 230 Mtr. complete with motor, base plate, coupling and coupling guards 2900 RPM |
| 884 | Supply of Oil cooled fully Automatic ATS Star Delta starter as per specification for above pumping plant. |
| 885 | Control panel with one no. incoming & 2nos. Outgoing as per specification. |
| 886 | Power wiring and earthing material as per specification and site requirement |
| 887 | Main piping and Valves |
| 888 | SITC of AC based diaphram operated dual solenoid control valve sluice valve (2 Nos) for flow / presssure / level controlling with controller / RTU PN 10/16, Bonnet- DI (GGG-50), tubing SS304, capable to transmit / communicate data to MIS as well as local control room server of 100 mm dia delivery pipeline. |
| 889 | Supply of pressure gauge & compound gauge with control cook air line fitting requirement. |
| 890 | Tools |
| 891 | Rubber Resistance Sheet 1Mt.x 2Mt x.025Mt. |
| 892 | Installation,commissioning & testing of pumping plant at site |
| 893 | Painting of above pumping plants with 2 coat of enamel paint. |
| 894 | Testing of pump set |
| 895 | (i) At Work |
| 896 | (ii) At Site |
| 897 | Carting of 2 sets of pumping plant with all material i.e.pumps motors, starters panel, pipe and special valves etc, from deptt. store haldwani to site |
| 898 | Prop. Sump Tallital to Prop. CWR Thakuda Pumping Plant (Centrifugal) |
| 899 | SITC of centrifugal pump set capable of delivering 450 LPM discharge , 260 Mtr. complete with motor, base plate, coupling and coupling guards 2900 RPM |
| 900 | Supply of Oil cooled fully Automatic ATS Star Delta starter as per specification for above pumping plant. |
| 901 | Control panel with one no. incoming & 2nos. Outgoing as per specification. |
| 902 | Power wiring and earthing material as per specification and site requirement |
| 903 | Main piping and Valves |
| 904 | SITC of AC based diaphram operated dual solenoid control valve sluice valve (2 Nos) for flow / presssure / level controlling with controller / RTU PN 10/16, Bonnet- DI (GGG-50), tubing SS304, capable to transmit / communicate data to MIS as well as local control room server of 100 mm dia delivery pipeline. |
| 905 | Supply of pressure gauge & compound gauge with control cook air line fitting requirement. |
| 906 | Tools |
| 907 | Rubber Resistance Sheet 1Mt.x 2Mt x.025Mt. |
| 908 | Servo Control Voltage Stabilizer 300 KVA suitable for regulating incoming voltage 300 to 480Volt , outgoing voltage 415Volt with suitable size of change over switch and copper cable, first filling of Transformer Oil and complete installation. |
| 909 | 400 Amp TPN main switch |
| 910 | H.O.T Crane including Travelling Trolly, Rail, 5.0 Ton capacity lift upto 6.0 Mtr with chainpully block complete |
| 911 | Internal & external Electrification of Pump house |
| 912 | Automatic Power Factor Control panel (APFC) upto 50KVAR with monitoring power factor of electrical system using sensors and micro processores |
| 913 | Autophase reseval Unit (APR) Panel |
| 914 | Installation,commissioning & testing of pumping plant at site |
| 915 | Painting of above pumping plants with 2 coat of enamel paint. |
| 916 | Testing of pump set |
| 917 | (i) At Work |
| 918 | (ii) At Site |
| 919 | Carting of 2 sets of pumping plant with all material i.e.pumps motors, starters panel, pipe and special valves etc, from deptt. store haldwani to site |
| 920 | Intelligent GSM/Web/PLC based Mini Remote Terminal Units/PLC with analog and digital parameters and features as specified mini T.W. and transmit data on GSM backbone. GSM based wireless Communication system capable to transfer and gather data from remote sites to master Control Stations (Voltage, Current, Power factor, Pumping running Hour etc.) with 6 Amp. Automatic Voltage stabilizer including high and low cut and isolation transformer including Erection, testing and commissioining and modification of starter with AC and DC relays and necessary wiring complete in all respect. |
| 921 | S/F of data commmunication gatway devices for data acquisition and communication gateway devices for data acquisition and communication to IOT based cloud server centralized system with stand protocol using wi-fi / GPRS ethernet for atteast 02 months data backup with all accessories. |
| 922 | Over voltage & under voltage trip protection (350 V-450 V) |
| 923 | IOT based intelligent Pressure transmitter capable to communicate / transmit data to MIS as well as local control room servor for tubewell |
| 924 | IOT based Electro magnetic flow meter of 80/100 mm size capable to communicate / transmit data to MIS as well as local control room servor for tubewell. |
| 925 | IOT based Energy meter |
| 926 | IOT based Actuator panels |
| 927 | Signal cabling between RTU/PLC and field instruments including screened/unscreened & control copper cable, etc complete in all respect |
| 928 | Prop. Sump Tallital to Prop. OHT Dhungsil (Staging-28m) Pumping Plant (Centrifugal) |
| 929 | SITC of centrifugal pump set capable of delivering 450 LPM discharge , 100 Mtr. complete with motor, base plate, coupling and coupling guards 2900 RPM |
| 930 | Supply of Oil cooled fully Automatic ATS Star Delta starter as per specification for above pumping plant. |
| 931 | Control panel with one no. incoming & 2nos. Outgoing as per specification. |
| 932 | Power wiring and earthing material as per specification and site requirement |
| 933 | Main piping and Valves |
| 934 | SITC of AC based diaphram operated dual solenoid control valve sluice valve (2 Nos) for flow / presssure / level controlling with controller / RTU PN 10/16, Bonnet- DI (GGG-50), tubing SS304, capable to transmit / communicate data to MIS as well as local control room server of 80 mm dia delivery pipeline. |
| 935 | Supply of pressure gauge & compound gauge with control cook air line fitting requirement. |
| 936 | Tools |
| 937 | Rubber Resistance Sheet 1Mt.x 2Mt x.025Mt. |
| 938 | Installation,commissioning & testing of pumping plant at site |
| 939 | Painting of above pumping plants with 2 coat of enamel paint. |
| 940 | Testing of pump set |
| 941 | (i) At Work |
| 942 | (ii) At Site |
| 943 | Carting of 2 sets of pumping plant with all material i.e.pumps motors, starters panel, pipe and special valves etc, from deptt. store haldwani to site |
| 944 | Prop. Sump Danth to Prop. CWR Bilaspur |
| 945 | Pumping Plant (Centrifugal) |
| 946 | SITC of centrifugal pump set capable of delivering 500 LPM discharge , 180 Mtr. complete with motor, base plate, coupling and coupling guards 2900 RPM |
| 947 | Supply of Oil cooled fully Automatic ATS Star Delta starter as per specification for above pumping plant. |
| 948 | Control panel with one no. incoming & 2nos. Outgoing as per specification. |
| 949 | Power wiring and earthing material as per specification and site requirement |
| 950 | Main piping and Valves |
| 951 | SITC of AC based diaphram operated dual solenoid control valve sluice valve (2 Nos) for flow / presssure / level controlling with controller / RTU PN 10/16, Bonnet- DI (GGG-50), tubing SS304, capable to transmit / communicate data to MIS as well as local control room server of 100 mm dia delivery pipeline. |
| 952 | Supply of pressure gauge & compound gauge with control cook air line fitting requirement. |
| 953 | Tools |
| 954 | Rubber Resistance Sheet 1Mt.x 2Mt x.025Mt. |
| 955 | Servo Control Voltage Stabilizer 100 KVA suitable for regulating incoming voltage 300 to 480Volt , outgoing voltage 415Volt with suitable size of change over switch and copper cable, first filling of Transformer Oil and complete installation. |
| 956 | 200 Amp TPN main switch |
| 957 | H.O.T Crane including Travelling Trolly, Rail, 5.0 Ton capacity lift upto 6.0 Mtr with chainpully block complete |
| 958 | Internal & external Electrification of Pump house |
| 959 | Automatic Power Factor Control panel (APFC) upto 20 KVAR with monitoring power factor of electrical system using sensors and micro processores |
| 960 | Autophase reseval Unit (APR) Panel |
| 961 | Installation,commissioning & testing of pumping plant at site |
| 962 | Painting of above pumping plants with 2 coat of enamel paint. |
| 963 | Testing of pump set |
| 964 | (i) At Work |
| 965 | (ii) At Site |
| 966 | Carting of 2 sets of pumping plant with all material i.e.pumps motors, starters panel, pipe and special valves etc, from deptt. store haldwani to site |
| 967 | Complete internal and external electrification of all Pump Houses, staf Quarters and campus with LED lightning. |
| 968 | Intelligent GSM/Web/PLC based Mini Remote Terminal Units/PLC with analog and digital parameters and features as specified mini T.W. and transmit data on GSM backbone. GSM based wireless Communication system capable to transfer and gather data from remote sites to master Control Stations (Voltage, Current, Power factor, Pumping running Hour etc.) with 6 Amp. Automatic Voltage stabilizer including high and low cut and isolation transformer including Erection, testing and commissioining and modification of starter with AC and DC relays and necessary wiring complete in all respect. |
| 969 | S/F of data commmunication gatway devices for data acquisition and communication gateway devices for data acquisition and communication to IOT based cloud server centralized system with stand protocol using wi-fi / GPRS ethernet for atteast 02 months data backup with all accessories. |
| 970 | Over voltage & under voltage trip protection (350 V-450 V) |
| 971 | IOT based intelligent Pressure transmitter capable to communicate / transmit data to MIS as well as local control room servor for tubewell |
| 972 | IOT based Electro magnetic flow meter of 100 mm size capable to communicate / transmit data to MIS as well as local control room servor for tubewell. |
| 973 | IOT based Energy meter |
| 974 | IOT based Actuator panels |
| 975 | Signal cabling between RTU/PLC and field instruments including screened/unscreened & control copper cable, etc complete in all respect |
| 976 | Prop. Sump Silauti Pant to Prop. CWR Sillauti Pant |
| 977 | Pumping Plant (Centrifugal) |
| 978 | SITC of centrifugal pump set capable of delivering 350 LPM discharge , 105 Mtr. complete with motor, base plate, coupling and coupling guards 2900 RPM |
| 979 | Supply of Oil cooled fully Automatic ATS Star Delta starter as per specification for above pumping plant. |
| 980 | Control panel with one no. incoming & 2nos. Outgoing as per specification. |
| 981 | Power wiring and earthing material as per specification and site requirement |
| 982 | Main piping and Valves |
| 983 | SITC of AC based diaphram operated dual solenoid control valve sluice valve (2 Nos) for flow / presssure / level controlling with controller / RTU PN 10/16, Bonnet- DI (GGG-50), tubing SS304, capable to transmit / communicate data to MIS as well as local control room server of 80 mm dia delivery pipeline. |
| 984 | Supply of pressure gauge & compound gauge with control cook air line fitting requirement. |
| 985 | Tools |
| 986 | Rubber Resistance Sheet 1Mt.x 2Mt x.025Mt. |
| 987 | Servo Control Voltage Stabilizer 50 KVA suitable for regulating incoming voltage 300 to 480Volt , outgoing voltage 415Volt with suitable size of change over switch and copper cable, first filling of Transformer Oil and complete installation. |
| 988 | 100 Amp TPN main switch |
| 989 | H.O.T Crane including Travelling Trolly, Rail, 5.0 Ton capacity lift upto 6.0 Mtr with chainpully block complete |
| 990 | Internal & external Electrification of Pump house |
| 991 | Automatic Power Factor Control panel (APFC) upto 7.5 KVAR with monitoring power factor of electrical system using sensors and micro processores |
| 992 | Autophase reseval Unit (APR) Panel |
| 993 | Installation,commissioning & testing of pumping plant at site |
| 994 | Painting of above pumping plants with 2 coat of enamel paint. |
| 995 | Testing of pump set |
| 996 | (i) At Work |
| 997 | (ii) At Site |
| 998 | Carting of 2 sets of pumping plant with all material i.e.pumps motors, starters panel, pipe and special valves etc, from deptt. store haldwani to site |
| 999 | Intelligent GSM/Web/PLC based Mini Remote Terminal Units/PLC with analog and digital parameters and features as specified mini T.W. and transmit data on GSM backbone. GSM based wireless Communication system capable to transfer and gather data from remote sites to master Control Stations (Voltage, Current, Power factor, Pumping running Hour etc.) with 6 Amp. Automatic Voltage stabilizer including high and low cut and isolation transformer including Erection, testing and commissioining and modification of starter with AC and DC relays and necessary wiring complete in all respect. |
| 1000 | S/F of data commmunication gatway devices for data acquisition and communication gateway devices for data acquisition and communication to IOT based cloud server centralized system with stand protocol using wi-fi / GPRS ethernet for atteast 02 months data backup with all accessories. |
| 1001 | Over voltage & under voltage trip protection (350 V-450 V) |
| 1002 | IOT based intelligent Pressure transmitter capable to communicate / transmit data to MIS as well as local control room servor for tubewell |
| 1003 | IOT based Electro magnetic flow meter of 80 mm size capable to communicate / transmit data to MIS as well as local control room servor for tubewell. |
| 1004 | IOT based Energy meter |
| 1005 | IOT based Actuator panels |
| 1006 | Signal cabling between RTU/PLC and field instruments including screened/unscreened & control copper cable, etc complete in all respect |
| 1007 | Prop. Sump Naul to Ex. CWR Bijrauli |
| 1008 | Pumping Plant (Centrifugal) |
| 1009 | SITC of centrifugal pump set capable of delivering 150 LPM discharge , 375 Mtr. complete with motor, base plate, coupling and coupling guards 2900 RPM |
| 1010 | Supply of Oil cooled fully Automatic ATS Star Delta starter as per specification for above pumping plant. |
| 1011 | Control panel with one no. incoming & 2nos. Outgoing as per specification. |
| 1012 | Power wiring and earthing material as per specification and site requirement |
| 1013 | Main piping and Valves |
| 1014 | SITC of AC based diaphram operated dual solenoid control valve sluice valve (2 Nos) for flow / presssure / level controlling with controller / RTU PN 10/16, Bonnet- DI (GGG-50), tubing SS304, capable to transmit / communicate data to MIS as well as local control room server of 80 mm dia delivery pipeline. |
| 1015 | Supply of pressure gauge & compound gauge with control cook air line fitting requirement. |
| 1016 | Tools |
| 1017 | Rubber Resistance Sheet 1Mt.x 2Mt x.025Mt. |
| 1018 | Installation,commissioning & testing of pumping plant at site |
| 1019 | Painting of above pumping plants with 2 coat of enamel paint. |
| 1020 | Testing of pump set |
| 1021 | (i) At Work |
| 1022 | (ii) At Site |
| 1023 | Carting of 2 sets of pumping plant with all material i.e.pumps motors, starters panel, pipe and special valves etc, from deptt. store haldwani to site |
| 1024 | Prop. Sump Naul to Prop. CWR Thaplia Mehra Gaon |
| 1025 | Pumping Plant (Centrifugal) |
| 1026 | SITC of centrifugal pump set capable of delivering 600 LPM discharge , 420 Mtr. complete with motor, base plate, coupling and coupling guards 2900 RPM |
| 1027 | Supply of Oil cooled fully Automatic ATS Star Delta starter as per specification for above pumping plant. |
| 1028 | Control panel with one no. incoming & 2nos. Outgoing as per specification. |
| 1029 | Power wiring and earthing material as per specification and site requirement |
| 1030 | Main piping and Valves |
| 1031 | SITC of AC based diaphram operated dual solenoid control valve sluice valve (2 Nos) for flow / presssure / level controlling with controller / RTU PN 10/16, Bonnet- DI (GGG-50), tubing SS304, capable to transmit / communicate data to MIS as well as local control room server of 100 mm dia delivery pipeline. |
| 1032 | Supply of pressure gauge & compound gauge with control cook air line fitting requirement. |
| 1033 | Tools |
| 1034 | Rubber Resistance Sheet 1Mt.x 2Mt x.025Mt. |
| 1035 | Servo Control Voltage Stabilizer 300KVA suitable for regulating incoming voltage 300 to 480Volt , outgoing voltage 415Volt with suitable size of change over switch and copper cable, first filling of Transformer Oil and complete installation. |
| 1036 | 400 Amp TPN main switch |
| 1037 | H.O.T Crane including Travelling Trolly, Rail, 5.0 Ton capacity lift upto 6.0 Mtr with chainpully block complete |
| 1038 | Internal & external Electrification of Pump house |
| 1039 | Automatic Power Factor Control panel (APFC) upto 60 KVAR with monitoring power factor of electrical system using sensors and micro processores |
| 1040 | Autophase reseval Unit (APR) Panel |
| 1041 | Installation,commissioning & testing of pumping plant at site |
| 1042 | Painting of above pumping plants with 2 coat of enamel paint. |
| 1043 | Testing of pump set |
| 1044 | (i) At Work |
| 1045 | (ii) At Site |
| 1046 | Carting of 2 sets of pumping plant with all material i.e.pumps motors, starters panel, pipe and special valves etc, from deptt. store haldwani to site |
| 1047 | Intelligent GSM/Web/PLC based Mini Remote Terminal Units/PLC with analog and digital parameters and features as specified mini T.W. and transmit data on GSM backbone. GSM based wireless Communication system capable to transfer and gather data from remote sites to master Control Stations (Voltage, Current, Power factor, Pumping running Hour etc.) with 6 Amp. Automatic Voltage stabilizer including high and low cut and isolation transformer including Erection, testing and commissioining and modification of starter with AC and DC relays and necessary wiring complete in all respect. |
| 1048 | S/F of data commmunication gatway devices for data acquisition and communication gateway devices for data acquisition and communication to IOT based cloud server centralized system with stand protocol using wi-fi / GPRS ethernet for atteast 02 months data backup with all accessories. |
| 1049 | Over voltage & under voltage trip protection (350 V-450 V) |
| 1050 | IOT based intelligent Pressure transmitter capable to communicate / transmit data to MIS as well as local control room servor for tubewell |
| 1051 | IOT based Electro magnetic flow meter of 80/100 mm size capable to communicate / transmit data to MIS as well as local control room servor for tubewell. |
| 1052 | IOT based Energy meter |
| 1053 | IOT based Actuator panels |
| 1054 | Signal cabling between RTU/PLC and field instruments including screened/unscreened & control copper cable, etc complete in all respect |
| 1055 | Ex. Sump Chunauti to prop. CWR Chunauti |
| 1056 | Pumping Plant (Centrifugal) |
| 1057 | SITC of centrifugal pump set capable of delivering 100 LPM discharge , 170 Mtr. complete with motor, base plate, coupling and coupling guards 2900 RPM |
| 1058 | Supply of Oil cooled fully Automatic ATS Star Delta starter as per specification for above pumping plant. |
| 1059 | Control panel with one no. incoming & 2nos. Outgoing as per specification. |
| 1060 | Power wiring and earthing material as per specification and site requirement |
| 1061 | Main piping and Valves |
| 1062 | SITC of AC based diaphram operated dual solenoid control valve sluice valve (2 Nos) for flow / presssure / level controlling with controller / RTU PN 10/16, Bonnet- DI (GGG-50), tubing SS304, capable to transmit / communicate data to MIS as well as local control room server of 80 mm dia delivery pipeline. |
| 1063 | Supply of pressure gauge & compound gauge with control cook air line fitting requirement. |
| 1064 | Tools |
| 1065 | Rubber Resistance Sheet 1Mt.x 2Mt x.025Mt. |
| 1066 | Servo Control Voltage Stabilizer 20KVA suitable for regulating incoming voltage 300 to 480Volt , outgoing voltage 415Volt with suitable size of change over switch and copper cable, first filling of Transformer Oil and complete installation. |
| 1067 | 63 Amp TPN main switch |
| 1068 | H.O.T Crane including Travelling Trolly, Rail, 5.0 Ton capacity lift upto 6.0 Mtr with chainpully block complete |
| 1069 | Internal & external Electrification of Pump house |
| 1070 | Automatic Power Factor Control panel (APFC) upto 5 KVAR with monitoring power factor of electrical system using sensors and micro processores |
| 1071 | Autophase reseval Unit (APR) Panel |
| 1072 | Installation,commissioning & testing of pumping plant at site |
| 1073 | Painting of above pumping plants with 2 coat of enamel paint. |
| 1074 | Testing of pump set |
| 1075 | (i) At Work |
| 1076 | (ii) At Site |
| 1077 | Carting of 2 sets of pumping plant with all material i.e.pumps motors, starters panel, pipe and special valves etc, from deptt. store haldwani to site |
| 1078 | Intelligent GSM/Web/PLC based Mini Remote Terminal Units/PLC with analog and digital parameters and features as specified mini T.W. and transmit data on GSM backbone. GSM based wireless Communication system capable to transfer and gather data from remote sites to master Control Stations (Voltage, Current, Power factor, Pumping running Hour etc.) with 6 Amp. Automatic Voltage stabilizer including high and low cut and isolation transformer including Erection, testing and commissioining and modification of starter with AC and DC relays and necessary wiring complete in all respect. |
| 1079 | S/F of data commmunication gatway devices for data acquisition and communication gateway devices for data acquisition and communication to IOT based cloud server centralized system with stand protocol using wi-fi / GPRS ethernet for atteast 02 months data backup with all accessories. |
| 1080 | Over voltage & under voltage trip protection (350 V-450 V) |
| 1081 | IOT based intelligent Pressure transmitter capable to communicate / transmit data to MIS as well as local control room servor for tubewell |
| 1082 | IOT based Electro magnetic flow meter of 80 mm size capable to communicate / transmit data to MIS as well as local control room servor for tubewell. |
| 1083 | IOT based Energy meter |
| 1084 | IOT based Actuator panels |
| 1085 | Signal cabling between RTU/PLC and field instruments including screened/unscreened & control copper cable, etc complete in all respect |
| 1086 | Construction of Solar Power Plant for 15 KW |
| 1087 | Solar Monocrystalline PV module minimum 550/570 Wp for 15KW to ensure the output. |
| 1088 | String invertor with power exporting facility to the grid having out put shall be 415 V AC, 50 H3, 3 Phase degree of protection IP-65 with self protective and self diagnositic features such as over voltage over current (both input and output) over/ under grid frequency, over temperature short curcuit , lightening, islanding and surge voltage competable mean in each and every sense to synchronize with UPCL grid. |
| 1089 | Hot dipped Galvanised structure including SS nut bolts at campus of pump housecomplete with grouting by cement concrete etc. |
| 1090 | DCDB box between solar panels and the invertor containing DC SPD and DC MCB with fuse set complete |
| 1091 | ACDB box with protective devices for overload and short circuit in between invertpr and AC side |
| 1092 | Copper bonded Lightening arrestor & surge protection. |
| 1093 | Fire extenguisher 5 Kg. |
| 1094 | 03 Nos.Chemical earthing complete with 1 core 4 sqmm earth wire PVC pits etc as per IE rule |
| 1095 | Cabling work by copper 4 core AC cable and One core DC cable including HDPE conduit pipe for carrying the copper conductor |
| 1096 | Miscellenious work i.e. meter testing and commissioning of transformer with fixing of 1.1 KV power cable , Fire safety system etc. |
| 1097 | SITC of Data logging system (Hard ware and software) for measuring solar irradiance, temperature, AC voltage AC output current output power, energy DC input voltage DC input Current, Temperature invertor stutus, module temperature string voltage & current through GSM modem / wifi with storage of data along with display port MCS (Master Control Station) |
| 1098 | Net metering complete as per UPCL guideline with meter box (including fixing of solar meter ) and all accessories as per site. |
| 1099 | Field Automation distribution network for all zone DMA & Master Control Station (MCS) |
| 1100 | SITC OF FIELD AUTOMATION |
| 1101 | SITC of solar supply / AC based of smart I.O.T. Device (SID0909) with common neno SIM card for live video streaming and secured data transmisssion from the PLC using telementary protocols such as MQTT/AMQP/HTTPS and send data to cloud web enable SCADA with memory of storing data for minimum 15 days. |
| 1102 | SITC of solar supply / AC based diaphram operated dual solenoid control valve for flow / presssure / level controlling with controller / RTU PN 10/16, Bonnet- DI (GGG-50), tubing SS304, capable to transmit / communicate data to MIS as well as local control room server of 40 mm line size with seperate earthing arrangement with seperate earthing arrangement. |
| 1103 | SITC of solar supply / AC based diaphram operated dual solenoid control valve for flow / presssure / level controlling with controller / RTU PN 10/16, Bonnet- DI (GGG-50), tubing SS304, capable to transmit / communicate data to MIS as well as local control room server of 65 mm line sizes with seperate earthing arrangement.. |
| 1104 | SITC of solar supply / AC based diaphram operated dual solenoid control valve for flow / presssure / level controlling with controller / RTU PN 10/16, Bonnet- DI (GGG-50), tubing SS304, capable to transmit / communicate data to MIS as well as local control room server of 100 mm line sizes with seperate earthing arrangement. |
| 1105 | SITC of solar supply / AC based diaphram operated dual solenoid control valve for flow / presssure / level controlling with controller / RTU PN 10/16, Bonnet- DI (GGG-50), tubing SS304, capable to transmit / communicate data to MIS as well as local control room server of 125 mm line sizes with seperate earthing arrangement. |
| 1106 | SITC of solar supply / AC based diaphram operated dual solenoid control valve for flow / presssure / level controlling with controller / RTU PN 10/16, Bonnet- DI (GGG-50), tubing SS304, capable to transmit / communicate data to MIS as well as local control room server of 150 mm line size with seperate earthing arrangement with seperate earthing arrangement. |
| 1107 | SITC of solar supply / AC based diaphram operated dual solenoid control valve for flow / presssure / level controlling with controller / RTU PN 10/16, Bonnet- DI (GGG-50), tubing SS304, capable to transmit / communicate data to MIS as well as local control room server of 200 mm line size with seperate earthing arrangement with seperate earthing arrangement. |
| 1108 | SITC of solar supply / AC based ,IOT based Electro magnetic flow meter capable to communicate/transmit data to MIS as well as local control room server of 40mm sizes for distribution line with seperate earthing arrangement. |
| 1109 | SITC of solar supply / AC based ,IOT based Electro magnetic flow meter capable to communicate/transmit data to MIS as well as local control room server of 65 mm sizes for distribution line with seperate earthing arrangement. |
| 1110 | SITC of solar supply / AC based ,IOT based Electro magnetic flow meter capable to communicate/transmit data to MIS as well as local control room server of 100 mm sizes for distribution linewith seperate earthing arrangement. |
| 1111 | SITC of solar supply / AC based ,IOT based Electro magnetic flow meter capable to communicate/transmit data to MIS as well as local control room server of 125 mm sizes for distribution linewith seperate earthing arrangement. |
| 1112 | SITC of solar supply / AC based ,IOT based Electro magnetic flow meter capable to communicate/transmit data to MIS as well as local control room server of 150 mm sizes for distribution line with seperate earthing arrangement. |
| 1113 | SITC of solar supply / AC based ,IOT based Electro magnetic flow meter capable to communicate/transmit data to MIS as well as local control room server of 200 mm sizes for distribution line with seperate earthing arrangement. |
| 1114 | SITC of solar supply / AC operated IOT based intelligent Pressure transmitter capable to communicate / transmit data to MIS as well as local control room servor for DMA |
| 1115 | SITC of solar supply / AC based Online TDS/ PH Chorine/ Turbidity / Water Quality Analyser with local display with Data LOGGER with 4G IOT Interated.Meterwith communication, measuring with LCD display, . |
| 1116 | SITC of solar supply / AC based diaphram operated ultrasonic type level transmitter ( Digital/analog (4-20mA, RS485, etc.) for OHT/CWR complete with all necessary accessories complete as per technical specification level transmitter should be capable of transmitting data to SCADA system and portal. |
| 1117 | SITC OF MASTER CONTROL STATION |
| 1118 | Supply and installation of a high-performance SCADA server (Intel i7/i9 or Xeon, 32–64GB RAM, SSD+HDD) with external backup/NAS storage for data safety. Network infrastructure includes a managed gigabit switch, firewall router for secure remote access, and static IP internet connection (minimum 10 Mbps).Software package consists of SCADA license, time-series database, dashboard/visualization tools, OS license (Windows Server/Linux), antivirus, and optional remote access tools.Display and control interface features a 55-inch 4K Ultra HD smart LED monitor, wireless keyboard and mouse, operator workstation PC, and laser printer for reports.Room setup includes an electrical distribution board with MCBs, a 1.5-ton 5-star split AC for cooling, adequate power sockets (6–8 nos), LED lighting fixtures, and earthing and surge protection systems.Furniture and accessories comprise an ergonomic operator table, two office chairs, a server rack (6U–12U), whiteboard/notice board, CO2 fire extinguisher, and documentation rack/file cabinet. |
| 1119 | CCTV camera at pump house with 2 MP, IP dome CCTV colour night vision, Dline 2 port POE switch full Giga, D link connector PVC box, complete wireless communication setup and 128 GB memory card. |
| 1120 | Industrical type UPS of 2 Kva with 150 AH*2 Battery Unit, Backup For 2 Hours for control supply of automation at I/well |
| 1121 | Transformer and Accessories for Mehra Gaon-I & II |
| 1122 | 315 KVA Transformers as Per Specification and site requirement with automatic Tap Changer.H.T. Panel as per specification and site requirement. 1 No.50sq. mm H.T. XLPE cable armoured from H.T. panel to 11/0.44KV Tranformer side including cable jointing material - 50 mtrs11KV jointing kit complete (Indoor + Outdoor) for each nos. sub station.- 2 SetsMaking of earth station for transformer, HT Panel including all material as per IE rules -2 Jobs185 mm2 3.5 core Al. Armoured cable Transformer to Main Switch - 20 mtrs |
| 1123 | Transformer and Accessories for prop Pump House To Prop CWR Bijrauli & Thaplia Mehra Gaon |
| 1124 | 315 KVA Transformers as Per Specification and site requirement with automatic Tap Changer.H.T. Panel as per specification and site requirement-1 No.50sq. mm H.T. XLPE cable armoured from H.T. panel to 11/0.44KV Tranformer side including cable jointing material-50 Mtrs11KV jointing kit complete (Indoor + Outdoor) for each nos. substation-2 SetsMaking of earth station for transformer, HT Panel including all material as per IE rules-2 Jobs240 mm2 3.5 core Al. Armoured cable Transformer to Main Switch-50 Mtrs |
| 1125 | Transformer and Accessories for prop Pump House Sangadi Gaon, Thakuda, Dhungsil |
| 1126 | 315 KVA Transformers as Per Specification and site requirement with automatic Tap Changer.H.T. Panel as per specification and site requirement-1 No.50sq. mm H.T. XLPE cable armoured from H.T. panel to 11/0.44KV Tranformer side including cable jointing material-50 Mtrs11KV jointing kit complete (Indoor + Outdoor) for each nos. sub station-2 SetsMaking of earth station for transformer, HT Panel including all material as per IE rules-2 Jobs240 mm2 3.5 core Al. Armoured cable Transformer to Main Switch-50 Mtrs |
| 1127 | Transformer and Accessories for Prop. Pump House Khutani, Vikas Bhawan, & Saon Gaon |
| 1128 | 250 KVA Transformers as Per Specification and site requirement with automatic Tap Changer.H.T. Panel as per specification and site requirement 1 No.50sq. mm H.T. XLPE cable armoured from H.T. panel to 11/0.44KV Tranformer side including cable jointing material-50 Mtrs11KV jointing kit complete (Indoor + Outdoor) for each nos. substation-2 SetsMaking of earth station for transformer, HT Panel including all material as per IE rules-2 Jobs150 mm2 3.5 core Al. Armoured cable Transformer to Main Switch-50 Mtrs |
| 1129 | Transformer and Accessories for Prop. Pump House Jijhari To CWR Talla |
| 1130 | 250 KVA Transformers as Per Specification and site requirement with automatic Tap Changer.H.T. Panel as per specification and site requirement- 1 No.35sq. mm H.T. XLPE cable armoured from H.T. panel to 11/0.44KV Tranformer side including cable jointing material-50 Mtrs11KV jointing kit complete (Indoor + Outdoor) for each nos. substation-2 setsMaking of earth station for transformer, HT Panel including all material as per IE rules-2 Jobs150 mm2 3.5 core Al. Armoured cable Transformer to Main Switch-50 Mtrs |
| 1131 | Transformer and Accessories for Prop Pump House To Prop CWR Bhagtura |
| 1132 | 160 KVA Transformers as Per Specification and site requirement with automatic Tap Changer.H.T. Panel as per specification and site requirement -1 No.35sq. mm H.T. XLPE cable armoured from H.T. panel to 11/0.44KV Tranformer side including cable jointing material-50 Mtrs11KV jointing kit complete (Indoor + Outdoor) for each nos. sub station-2 SetsMaking of earth station for transformer, HT Panel including all material as per IE rules-2 Jobs120 mm2 3.5 core Al. Armoured cable Transformer to Main Switch-50 Mtrs |
| 1133 | Transformer and Accessories for Prop. Pump House Danth To CWR Bilaspur |
| 1134 | 125 KVA Transformers as Per Specification and site requirement with automatic Tap Changer.H.T. Panel as per specification and site requirement - 1 No.35 sq. mm H.T. XLPE cable armoured from H.T. panel to 11/0.44KV Tranformer side including cable jointing material-50 Mtrs11KV jointing kit complete (Indoor + Outdoor) for each nos. substation - 2 SetsMaking of earth station for transformer, HT Panel including all material as per IE rules - 2 Jobs95 mm2 3.5 core Al. Armoured cable Transformer to Main Switch-50 Mtrs |
| 1135 | Cost for Trial & Run for 4 Months |
| 1136 | Praparetion of Environmental and Social Management Plan (ESMP) Cost |
| 1137 | Operation & Maintenance for 7 years |
| 1138 | O&M Cost for 1st Yr. |
| 1139 | O&M Cost for 2nd Yr. |
| 1140 | O&M Cost for 3rd Yr. |
| 1141 | O&M Cost for 4th Yr. |
| 1142 | O&M Cost for 5th Yr. |
| 1143 | O&M Cost for 6th Yr. |
| 1144 | O&M Cost for 7th Yr. |
| 1145 | Operation & Maintenance of existing facilities of Old Nagar Palika, Bhimtal area (Ward No. 1 to 9) from which some part of the existing system will also be reuse in the new system as on where on basis, as per existing duration of water supply i/c billing & collection of tarrif from (to be deposited in the dedicated govt account) in all zone of Bhimtal Water Supply Scheme, having 5 GLSR, 8 Nos. Tube Wells, Pump House, Sump cum Pump House, 2323 Nos. House Service Connection, Supply Feeder Main, 7200 m Rising Main, 75.07 km (Approx) Distribution System Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 5 daysCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 11 daysCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 11 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender