Tender For Supply, Erection And Commissioning Of 03 No. Dg Sets Of Different Capacity As Per Site Condition At Permanent Pump Houses At Rd 5750 Of Pilana Minor, Rd 169500 Of Kahanaur Disty., Rd 8000 (Sanghi-I Pump House) Of Sanghi Minor And Rd 10000
Tender Overview
Project Description
Tender for Supply, Erection And Commissioning Of 03 No. Dg Sets Of Different Capacity As Per Site Condition At Permanent Pump Houses At Rd 5750 Of Pilana Minor, Rd 169500 Of Kahanaur Disty., Rd 8000 (Sanghi-I Pump House) Of Sanghi Minor And Rd 10000 Of Jindran Pump House.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 09-Oct-2026 | Corrigendum | Other | 21-Oct-2026 |
| 2 | 23-Oct-2026 | Corrigendum2 | Date | 27-Oct-2026 |
| 3 | 09-Oct-2026 | Corrigendum | Other | 27-Oct-2026 |
| 4 | 20-Oct-2026 | Corrigendum | Technical Bid | 27-Oct-2026 |
| 5 | 09-Oct-2026 | Corrigendum | Other | 02-Nov-2026 |
| 6 | 20-Oct-2026 | Corrigendum | Technical Bid | 02-Nov-2026 |
| 7 | 27-Oct-2026 | Extension of date | Date | 02-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Designing, Supply & erection of DG set of capacity given below with noise controlled devices acoustic of suitable rating, testing and commissioning of diesel generating set, radiator cooled, 3 phase, 4 wire, 50 cycles 415 +(-)1% volts AC alternator coupled directly through a set of flexible coupling on a common MS fabricated base frame with diesel engine complete with suitable size incoming cable from generator to change over/AMF panel, making 2nd incoming cable connection from transformer, outgoing cable connection from changeover/ standard panel, making second incoming cable connection from transformer, outgoing cable connection from changeover / STD panel to incomer of motor starter panel, complete earthing safety equipments fenced enclosure with platform for DG sets complete as per following detailed scope and specifications and directions of Engineer-in-charge. The rating should be at 1500 RPM. required accessories complete in all respects to the satisfaction of Engineer-in-charge (HSR-20.89.7) 125 KVA |
| 2 | Designing, Supply, Erection of DG set of capacity KVA with noise controlled device acoustics of suitable rating, testing and commissioning of diesel generating set, radiator cooled, 3 phase, 4 wire, 50 cycle 415+( -) 1â volts AC alternator coupled directly through a set of flexible coupling on a common MS fabricated base frame with diesel engine complete with suitable size incoming cable from generator to change over/ AMF panel, making 2nd incoming cable connecting from transformer, outgoing cable connection from changeover/standard panel, complete earthing safety equipments fenced wiring enclosure with platform from DG set complete as per following detailed scope and specification and direction of Engineer-in-charge. The rating should be at 1500 RPM .Required accessories complete in all respects to the satisfaction of Engineer-in-charge (HSR-20.89.10) 250 KVA |
| 3 | Designing, Supply, Erection of DG set of capacity KVA with noise controlled device acoustics of suitable rating, testing and commissioning of diesel generating set, radiator cooled, 3 phase, 4 wire, 50 cycle 415+( -) 1â volts AC alternator coupled directly through a set of flexible coupling on a common MS fabricated base frame with diesel engine complete with suitable size incoming cable from generator to change over/ AMF panel, making 2nd incoming cable connecting from transformer, outgoing cable connection from changeover/standard panel, complete earthing safety equipments fenced wiring enclosure with platform from DG set complete as per following detailed scope and specification and direction of Engineer-in-charge. The rating should be at 1500 RPM .Required accessories complete in all respects to the satisfaction of Engineer-in-charge (HSR-20.89.10) 160 KVA Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-4 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-5 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 4 daysCorrigendum-6 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 4 daysCorrigendum-7 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 4 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender