Tender For General-Phase Ii-2025-26: Savithri Bai Phule Memorial Ashram School-Construction Of Savithri Bai Phule Memmorial Ashram School- Kundamkuzhi-Composite Work
Tender Overview
Project Description
Tender for General-Phase Ii-2025-26: Savithri Bai Phule Memorial Ashram School-Construction Of Savithri Bai Phule Memmorial Ashram School- Kundamkuzhi-Composite Work
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 22-Oct-2026 | Date Corrigendum | Date | 02-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | SAVITHRIBAI PHULE MEMORIAL SHRAM SCHOOL(Civil work) |
| 2 | 15.3:Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. |
| 3 | 2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil |
| 4 | 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 5 | 2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil |
| 6 | 2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 7 | 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 8 | OD251404/2025-2026:Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note: Cement content considered in this item is @340 kg/ cum. Excess or less cement used as per design mix is not payable or recoverable separately. All work up to plinth level |
| 9 | OD251401/2025-2026:Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge.Note:- Cement content considered in this item is @ 340 kg/ cum. Excess or less cement used as per design mix is not payable or recoverable separately. All works above plinth level upto floor V level |
| 10 | 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 11 | 5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 12 | 5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts |
| 13 | 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform |
| 14 | 5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide |
| 15 | 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers |
| 16 | 5.9.19:Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges |
| 17 | 5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases) |
| 18 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 19 | 5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more |
| 20 | OD251402/2025-2026:Laterate masonry with neatly dressed laterate stone of size 30x20x20cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials , labour charges etc. |
| 21 | OD251395/2025-2026:Laterate masonry with neatly dressed laterate stone of size 30x20x20cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. |
| 22 | 50.6.3.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete |
| 23 | 13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) |
| 24 | 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 25 | 13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) |
| 26 | 50.13.1:9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete |
| 27 | 13.48.1:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm |
| 28 | 13.80:Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 29 | 13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer |
| 30 | 13.83.2:Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats |
| 31 | 9.147D.4:Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately)Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm). |
| 32 | 50.9.1.1:Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood |
| 33 | 50.9.3.1:Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 30 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction 0f Engineer in- charge. using Anjili/ Jack wood |
| 34 | 50.9.4.1:Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick using good quality Anjili/ Jack wood |
| 35 | 13.50.1:Applying priming coat:With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 36 | 13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 37 | 22.23.2:Providing and applying integral crystalline slurry of hydrophilic in nature forwaterproofing treatment to the RCC structures like retaining walls of the basement,water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 partsintegral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 partsintegral crystalline slurry : 1 part water) for horizontal surfaces and applying thesame from negative (internal) side with the help of synthetic fiber brush. The materialshall meet the requirements as specified in ACI-212-3R-2010 i.e by reducingpermeability of concrete by more than 90% compared with control concrete as perDIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystallineslurry shall be capable of self-healing of cracks up to a width of 0.50mm. The workshall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against anyleakage.For horizontal surface one coat @1.10 kg per sqm. |
| 38 | 22.23.1:Providing and applying integral crystalline slurry of hydrophilic in nature forwaterproofing treatment to the RCC structures like retaining walls of the basement,water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 partsintegral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 partsintegral crystalline slurry : 1 part water) for horizontal surfaces and applying thesame from negative (internal) side with the help of synthetic fiber brush. The materialshall meet the requirements as specified in ACI-212-3R-2010 i.e by reducingpermeability of concrete by more than 90% compared with control concrete as perDIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystallineslurry shall be capable of self-healing of cracks up to a width of 0.50mm. The workshall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against anyleakage.For vertical surface two coats @0.70 kg per sqm |
| 39 | 9.48.2:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc |
| 40 | 22.5:Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 41 | 11.41.2:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. |
| 42 | 11.46.2:Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm |
| 43 | 22.14.1:Grading roof for water proofing treatment with:Cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 44 | OD251398/2025-2026:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand),excluding grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.(epoxy grouting provided seperatly) |
| 45 | OD251396/2025-2026:Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), excluding grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm ( epoxy grouting provided separately) |
| 46 | 11.48.2:Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm |
| 47 | OD354591/2025-2026:Providing and laying matt finished vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. |
| 48 | 8.31:Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 49 | 8.2.2.2:Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm |
| 50 | 8.3.2:Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work |
| 51 | 9.121:Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. |
| 52 | 9.122.1:Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames. |
| 53 | 11.20.1:Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Light shade pigment using white cement |
| 54 | 8.10.2:Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in Charge and finished smooth.Granite Stone of approved shade |
| 55 | 10.28:Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 56 | 17.3.1:Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid |
| 57 | 17.7.5:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Angle back wash basin size 600x480 mm with single 15 mm C.P. brass pillar tap |
| 58 | 18.51.1:Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore |
| 59 | 50.17.1.4:Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. |
| 60 | 18.52.1:Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal bore |
| 61 | 18.53.1:Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore |
| 62 | 18.22.1:Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:100 mm diameter |
| 63 | 18.65:Providing and fixing PTMT Soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fittings arrangements, weighing not less than 106 gms. |
| 64 | 50.18.8.6.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2 |
| 65 | 50.18.7.6.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall |
| 66 | 50.18.9.6.2:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm dia 6 Kgf/cm2 |
| 67 | 50.18.7.3.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10Kgf/ cm2- Internal work- Exposed on wall |
| 68 | 50.18.9.21:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Elbow |
| 69 | 50.18.9.21.2:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia 45 degree Elbow |
| 70 | 50.18.9.21.3:Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia Door Elbow |
| 71 | 50.18.9.21.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend |
| 72 | 50.18.9.21.5:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75x75x75 mm dia Tee |
| 73 | 50.18.9.8.2:Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching and refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 4 Kgf/cm2 |
| 74 | 50.18.9.18.1:Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall |
| 75 | 50.18.8.9.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2 |
| 76 | 50.18.9.9.2:Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2 |
| 77 | 50.18.9.22.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow |
| 78 | 50.18.9.22.2:Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow |
| 79 | 50.18.9.22.3:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110 mm dia Door Elbow |
| 80 | 50.18.9.22.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend |
| 81 | 50.18.9.22.5:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee |
| 82 | 21.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) |
| 83 | 21.1.2.2:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 84 | 21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) |
| 85 | 50.18.8.2.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2 |
| 86 | 18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 87 | 18.32.1:Constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock, with C.I. surface box 100x100x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:With common burnt clay F.P.S (non modular) bricks of class designation 7.5 |
| 88 | 16.68:Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. |
| 89 | OD251403/2025-2026:Providing and fixing 1 mm thick Pressed steel sheet door with frame of 100x50x3 mm Hollow iron tube and 3 mm Pressed Steel gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer with supervision of engineer. |
| 90 | 13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work |
| 91 | OD251393/2025-2026:Filling 6mm broken stone in sunken slab including all cost carriage of materials and labour charges for filling etc complete. |
| 92 | 17.4.1:Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 93 | 50.18.9.22.8:Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl |
| 94 | 50.18.9.22.10:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia End Cap |
| 95 | 13.71:Lettering with black Japan pint of approved brand and manufacture |
| 96 | OD251394/2025-2026:Providing and laying Polished Granite stone in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 97 | 16.21:Engraving letters in hard stone |
| 98 | 17.10.1.4:Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink with drain board510x1040 mm bowl depth 178 mm |
| 99 | 9.100.1:Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm |
| 100 | 50.9.15.1:Supplying and fixing 200 mm Aluminium aldrop |
| 101 | 9.53:Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 102 | 9.97.5:Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:100x10 mm |
| 103 | OD251400/2025-2026:Supplying and fixing following furniture fittings 65mm Pad Lock Lever |
| 104 | 50.18.8.2.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chased and making good the wall etc. 20 mm pipe 12 Kgf/cm2 |
| 105 | 50.18.8.4.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 10Kgf/cm2 |
| 106 | 50.18.9.7.1:Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching refilling & testing of joints complete as per direction of Engineer in Charge. 63 mm dia 6Kgf/cm2 |
| 107 | 50.18.9.18.2:Providing and fixing PVC pipes including fixing the pipe with clamps/Clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 4 Kfg/cm2 - External work - Exposed on wall |
| 108 | 50.18.9.9.1:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 |
| 109 | 50.18.9.19.2:Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 m dia 4 Kgf/cm2 - External work - Exposed on wall |
| 110 | 50.18.9.16.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6Kgf/cm2 - External work - Exposed on wall |
| 111 | 50.18.9.22.9:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia offset |
| 112 | 50.18.9.22.6:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee |
| 113 | 50.18.9.22.11:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling |
| 114 | 18.58.1.1:Providing and fixing PTMT grating of approved quality and colour.Circular type100 mm nominal dia |
| 115 | 50.17.1.2:Supplying and fixing CP Towel rod 45cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. |
| 116 | 17.18.1:Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete.10 litre capacity - White |
| 117 | 17.1.1:Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 118 | 17.29:Providing and fixing 100 mm sand cast Iron grating for gully trap. |
| 119 | 17.31:Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 120 | 12.50:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 121 | 12.51.1:Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screwscomplete :Ridges plain (500-600 mm) |
| 122 | 50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 123 | OD251399/2025-2026:supplying laying and joining steel brackets including all cost and conveyance of materials and labour charges etc complete |
| 124 | OD251397/2025-2026:Supplying laying and joining 200 mm PVC rain water gutter including all cost and conveyance of materials and labour charges etc. Complete. |
| 125 | 25.6: Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc., all complete for the required performance as specified, as per the architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in - Charge. For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (Payment for fixing of Spandrel Glass panels in the curtain glazing is included in cost of relevent item*). ?(i) Coloured tinted float glass 6mm thicksubstrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. .The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. |
| 126 | 56.1.a:Mobilization including transportation of all necessary plant and equipment's and materials of boring, field testing and sampling and demobilization after completing the work - For machine boring |
| 127 | 56.2.a:Setting up boring at each bore hole locations including carrying all necessary plant, equipment and materials of boring and field tests and collection of samples at each bore hole location - For machine boring. |
| 128 | 56.11.a:Compilation of all field data with recommendation for a suitable foundation after conducting necessary lab test (report in triplicate) - Machine boring for 5 bore holes. |
| 129 | 56.3.a.1:Boring with rotary power drilling equipment's in - all types of soil having N value less than 50 excluding hard rock, soft rock or medium rock for strata upto 10m including conducting necessary S.P.T and recovery of undisturbed soil samples at 5m intervals - For ordinary soil. |
| 130 | 56.3.c.1:Boring with rotary power drilling equipment's in - all types of soil having N value less than 50 excluding hard rock, soft rock or medium rock for strata next 10m and upto a depth of 30m including conducting necessary S.P.T and recovery of undisturbed soil samples at 5m intervals - For ordinary soil. |
| 131 | 56.3.d.1:Boring with rotary power drilling equipment's in - all types of soil having N value less than 50 excluding hard rock, soft rock or medium rock for strata above 30m depth including conducting necessary S.P.T and recovery of undisturbed soil samples at 5m intervals - For ordinary soil. |
| 132 | 56.4:Boring through all type of hard rock or similar refusal strata of N value greater than 50 using diamond core drilling bit for in land under water and banks of river. |
| 133 | 56.6:Recovering undisturbed soil samples using thin tube sampler of 75mm.to 100mm length internal dia 500mm length conforming to relevant IS Code at any required depth including clearing the bore hole etc complete. |
| 134 | 56.7:Conducting standard penetration test in bore hole at any depth. |
| 135 | 56.8:Recovering disturbed samples and preserving the same in air tight sample containers including waxing labelling packing storing including cost of containers as per IS Code. |
| 136 | OD320339/2025-2026:Supplying and fixing 304- grade Stainless Steel 90 & deg; with Anti- Slip Nylon Grip wall Mounted Safety L shaped Grab Bar for toilets, including fixing charges etc. complete. |
| 137 | 10.2:Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 138 | 16.90:Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. |
| 139 | Electrification(Electrical work) |
| 140 | 1.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group A |
| 141 | 1.11:Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 142 | OD24330/2026-2027:Wiring combined plug point together with the light point/ fan point/ exhaust fanpoint/ call bell point including 6 A 5 pin modular socket controlled by 6A one waymodular switch in the existing switch board and giving connection to thephase,neutral and earth terminal with 1.5 sq.mm. FRLS PVC insulated copperconductor single core cable ( Green wire for earthing) etc as required. |
| 143 | 90.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture |
| 144 | 90.3.24.3:Supply & installation of light fittings suspended on ball & socket arrangement with 19 mm down rod Supply, conveyance, installation, testing and commissioning the light fittings of following types made of .5mm thick CRCA sheet accessories and lamps etc. including supplying and fixing ball and socket arrangements on PVC round block, suspension down rod of 19mm dia MS conduit up to 2x30cm length including painting and wiring the down rod with 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections etc. a required.1200 mm 1X20W LED Lamp with box type fixture |
| 145 | 90.3.21.3:Supply & installation of light fittings on 'C/U' shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture |
| 146 | OD42332/2026-2027: Supply ,installation,testing and commissioning of 700lm pressure die cast housing Bulk head with IP65 protection & IK 08 having efficacy not less than 105lm/W and giving connection with 3 core flex wire as required |
| 147 | 90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. |
| 148 | 90.4.2:Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required. |
| 149 | OD39553/2026-2027:Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 150 | 90.3.10:Supplying and providing extra H.G conduit down rod of 19 mm dia 2 x 1.00 m long with 16/0.20 mm 3 core copper conductor flex wire conforming to relevant ISS or with the extended original wiring and giving connection etc. as required. |
| 151 | OD39781/2026-2027:Supply ,installation,testing and commissioning of 8400 lumen LED, efficacy >=120 Lm/watt, IP 66 street light fitting with die-cast aluminium housing, polycarbonate cover complete with THD <10%, power factor >0.95, RoHS compliant, duly wired up for use on 230 V AC supply, IK >=7, with internal surge protection 4k above. Chip make Cree/Osram/lumilled/Nichea/Bridgelux.(LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 152 | OD39782/2026-2027:Supply ,installation,testing and commissioning of 4200 lumen LED, efficacy >=120 Lm/watt, IP 66 street light fitting with die-cast aluminium housing, polycarbonate cover complete with THD <10%, power factor >0.95, RoHS compliant, duly wired up for use on 230 V AC supply, IK >=7, with internal surge protection 4k above. Chip make Cree/Osram/lumilled/Nichea/Bridgelux.(LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 153 | OD39786/2026-2027:Supply ,installation, testing and commissioning of 5 metre hot dip galvanised Octogonal pole in single section with average galvanization 65 microns or above having minimum 70mm top diameter& 130mm bottom diameter with sheet having thickness 3mm( min),base plate dimensions of 200x200x12mm (min) with 0.5 M long single arm bracket suitable for 5M octogonal poles including connector . The Octagonal Poles should withstand the wind speed upto a min 39m/s as per IS 875 Part 3 .The pole should have inbuilt vandal resistant weather proof door mounting 500 mm above from ground with proper gaskets & alen key arrangement for safety locking.The Octagonal Poles shall be bolted on a cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required with a set of minimun four foundation bolts made from special steel galvanized along with nuts washers etc company make same as that of pole |
| 154 | OD39798/2026-2027: Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 1.5sq mm (clamped with 1mm thick saddle) |
| 155 | 90.3.18.2:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps |
| 156 | 90.5.1.4:Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Musical bell with bird sound |
| 157 | 90.5.1.3:Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Ding dong bell |
| 158 | OD317046/2025-2026:Supply, Conveyance, installation , testing and commissioning of 305 mm sweep, 1400 rpm Heavy Duty Exhaust fan working on 230 V A/C in metal frame in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan. |
| 159 | OD317060/2025-2026:Supply and installation of 300/305 mm sweep Light Duty Exhaust fan in metal frame working on 230 V A/C in the existing opening, including making good the damage connection testing, commissioning etc. as required. |
| 160 | 1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 161 | 1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 162 | 1.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm) |
| 163 | 1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) |
| 164 | 1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm) |
| 165 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 166 | 1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 167 | 90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator |
| 168 | 90.10.3.14:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A SP switch with indicator |
| 169 | 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 170 | 1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 171 | 90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket |
| 172 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 173 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 174 | 1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm |
| 175 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 176 | 1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm |
| 177 | 1.17.5:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 X 1.5 Sq. mm |
| 178 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 179 | 1.17.15:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm |
| 180 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 181 | 1.17.24:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 4 sq. mm |
| 182 | 1.17.33:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 6 sq. mm |
| 183 | 90.11.1.18:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 184 | 90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 185 | 90.11.1.11:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43) |
| 186 | 90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43) |
| 187 | 2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door |
| 188 | 2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door |
| 189 | OD317035/2025-2026: Supplying and fixing 4P sheet steel enclosure on surface/ recess testing and commissioning etc. as required |
| 190 | OD41372/2026-2027:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & shall conform to relevant IS .Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame) |
| 191 | 90.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet |
| 192 | 90.14.2.1:Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc. |
| 193 | 90.14.4:Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC) |
| 194 | 90.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required. |
| 195 | 90.14.7:Supply and providing copper earth bus in the panel board |
| 196 | 90.14.10.3:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL |
| 197 | 90.14.10.11:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.125A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC |
| 198 | 2.1.1:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 Amp TP & N |
| 199 | 2.1.2:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N |
| 200 | 2.1.3:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.100 Amp TP&N |
| 201 | 2.1.4:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.125 Amp TP & N |
| 202 | 90.14.11.13:MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A |
| 203 | OD317055/2025-2026:Supply and providing spreader/terminal adapter kit extended terminal for 4 pole MCCB of rating up to 125A(8 pcs) |
| 204 | 90.14.11.5:MCCB AccessoriesSupply and fixing 100 - 200A earth fault module of MCCB with builtin CBCT. |
| 205 | 90.14.11.12:MCCB AccessoriesSupply and fixing shunt release for all voltage range up to 630A. |
| 206 | OD24554/2026-2027:Supply and fixing of Cable alley, 100 x 40 mm aluminium anodised legend plates as required. |
| 207 | 2.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 208 | OD24555/2026-2027:Supply and fixing of Bus bar chamber, 100 x 40 mm aluminium anodised legend plates as required. |
| 209 | OD44078/2026-2027:Supply and providing Earth, 40 x 20 mm with 8 mm hole aluminum anodized legend plates inthe existing panel board as required |
| 210 | OD24556/2026-2027:Supply and fixing of 100 A, 2 Way neutral links mounted on DMC/SMC base and giving connection as required |
| 211 | OD24557/2026-2027:Supply and fixing of 160, HRC Fuse Base with HRC Fuse link and giving connection as required |
| 212 | OD24558/2026-2027:Supply and fixing of 150/5 A, 5 VA, accuracy class 1, Resin Cast Metering CT |
| 213 | OD24570/2026-2027:Supplying and fixing 2 A, 240/415 volts, Single pole "C" curve, miniature circuit breaker in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 214 | OD24559/2026-2027:Supply and fixing of Blue colour LED indicator, AC/DC, 22.5 mm cut out dia |
| 215 | OD24561/2026-2027:Supply and fixing of Red, Green, Black, Yellow, Orange colours LED indicator, AC/DC, 22.5 mm cut out dia |
| 216 | OD24560/2026-2027:Supply and fixing Digital Multifunction meter to read: V, A, F, 3 phase accuracy class 1 |
| 217 | 2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 218 | 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 219 | 2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps |
| 220 | 2.15.1:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.25 amps |
| 221 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 222 | 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 223 | 2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole |
| 224 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 225 | 2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 226 | 90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size |
| 227 | 90.12.10.4:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation77/63 mm or nearest size |
| 228 | OD43422/2026-2027:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size on wall surface as required. 4x16 sqmm (clamped with 1mm thick saddle) |
| 229 | OD43423/2026-2027:Supply and laying of one number PVC insulated and PVC sheathed / XLPE aluminium armoured power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size in the existing RCC/ HUME/ METAL pipe as required. 2X6 sqmm |
| 230 | OD43584/2026-2027:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size on wall surface as required. 3.5x50 sqmm (clamped with 25x3mm MS flat clamp) |
| 231 | OD43585/2026-2027:Supply and laying of one number PVC insulated and PVC sheathed / XLPE aluminium armoured power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size in the existing RCC/ HUME/ METAL pipe as required. 3.5 C X50 sqmm |
| 232 | OD43396/2026-2027:Supply and laying of one number PVC insulated and PVC sheathed / XLPE aluminium armoured power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size in the existing RCC/ HUME/ METAL pipe as required. 4x10 sqmm |
| 233 | OD43359/2026-2027:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp |
| 234 | 9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) |
| 235 | 9.1.22:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm) |
| 236 | 9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) |
| 237 | 9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) |
| 238 | 14.13.1:Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required50 mm dia |
| 239 | OD136839/2026-2027:Supplying and providing earth clamps for siemens/ tropodor type cable glands of suitable length and other dimensions noted along with each size of glands for the following sizes of cables as required.1.5 sq mm to 16 sq mm size cable with 12 mm wide x 1 mm thick clip |
| 240 | OD136840/2026-2027:Supplying and providing earth clamps for siemens/ tropodor type cable glands of suitable length and other dimensions noted along with each size of glands for the following sizes of cables as required.25 sq mm to 95 sq mm size cable with 20 mm wide x 1.2 mm thick clip |
| 241 | 7.10:Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
| 242 | OD317045/2025-2026:Supply and providing 2.00 mm thick, 3.3 kV, Synthetic elastromeric fire retardant insulating sheet |
| 243 | OD136835/2026-2027:Supply and providing Emergency Resuscitation poster 36"x24" ecovinyl First aid & CPR training Educational chart in conspicous space in electic room |
| 244 | 90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board |
| 245 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 246 | OD25210/2026-2027:Supply and providing test joint for the earthing system using 2 Nos of the following sizes ofstrips including cutting and bending to shape, drilling necessary holes and fixed to the wateringpipe etc as required. 2 x 25 x 3 mm GI strip |
| 247 | OD25218/2026-2027:Supply and providing earth lead from the test joint to the earth electrode using the followingsizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) andfixing firmly with plate test joint etc as required.25 mm X 3 mm G.I. strip |
| 248 | 5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 249 | OD41299/2026-2027: Providing and drawing 2.00 mm (14 SWG) copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 250 | OD41300/2026-2027:Providing and drawing 4.75 mm(6SWG) copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 251 | OD41301/2026-2027:Providing and drawing 2.65 mm (12 SWG) copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 252 | OD41302/2026-2027:Providing and drawing 3.15 mm (10 SWG) copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 253 | 90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG) |
| 254 | 90.16.5.5:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.75 mm (6 SWG) |
| 255 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 256 | 90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG) |
| 257 | OD317061/2025-2026:Supply and fixing 25x6mm brass bolt with hexagonal/square head, nut and washer as required |
| 258 | OD317057/2025-2026:Supply and fixing 12x3mm brass bolt with hexagonal/square head, nut and washer as required |
| 259 | OD317054/2025-2026:Supply and providing 25x3 mm brass nut and bolt etc as required |
| 260 | 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. |
| 261 | 14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. |
| 262 | OD25571/2026-2027:Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete .Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 263 | 14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels |
| 264 | OD317062/2025-2026:Supply Installation and testing and commissioning of 3 kVA with 15 min back upa) 1 ph to 1 phb) Input pf : 0.99 @ full loadc) Output pf : unity d) Input voltage range : 140V -280V with cut offe) THD : < 10%f) Overall Efficiency : >87%g) Ambient Temperature : 0-40°Ch) Generator Compatibility.i) Pure sine wave.j) Battery over charge & under charge cut off.l) Bypass arrangement. m) EN/IEC 620401 for General Safety compatibility n) EN/IEC 620402 for Electromagnetic Compatibility. o) EN/IEC 620403 for Performance p) EN/IEC 620404 for Environmental Compatibilityq) battery : exide / panasonic or equivalent |
| 265 | OD43239/2026-2027:Supply and installation of 2kVA Sine Plus Home UPS. BIS Certified 2kVA/24VDC Pure Sine Wave Inverter with UPS mode Selector for Computer application, DSP and Dual microprocessor controlled system, Capacity-2kVA With Isolation Transformer, Single Phase Input Single Phase output and Earth, Input power factor=0 .9, Input current Distortion, I-THD-<=5%, Nominal output voltage=230 V AC Single phase, Output voltage regulation- +/-1%, efficiency - >90%, Ventilzation=Forced Air cooled, LED Display for Mains on, Inverter on, Battery Low, Over Load,Trip , Common Alarm, - Battery low Pre-alarm, Trip, Output short circuit protection, Output over/under voltage, Battery over temperature alarm, Battery 12V/150Ah CPRI Certified Tubular Battery 2 Nos with battery stand. Mandatory Certification-ISO9001-2015, ISO14001 -2015, OHSAS 18001 : 2007, CE Certification AND BIS Certification, CPRI Certification for batteries. |
| 266 | OD41204/2026-2027:Supply ,Conveyance Installation ,Testing and Commissioning of 58.5 KVA DG set(CPCB 4+) as per the technical details given below. Engine. a. Make of Engine - As specified in accepted list of material. b. Type of Engine-Diesel Engine. c .No. of cylinder- Suitable to develop the required BHP as per manufacturer's standards. Digital Multi function meter with accuracy class 1 to read parameters such as KW,KVA, PF, voltage, Current Frequency etc: c) Digital type single function KWH meter with accuracy class 1, d) Method of Cooling; Liquid cooled with radiator. e) Aspiration -Turbo charged, charge after cooled. f) Design - Suitable for generating set operating. g) Output- As per manufactures standards. 2. Standard accessories with Diesel Engine. a) Fly wheel to suit flexible coupling b) Close Coupling c) Air cleaner d)Radiator with fan provided with fan guard. e) Fuel Pump f) Electronic Governor g) Fuel filter h) Exhaust silencer i) Exhaust Muffler j) Lubricating oil filter. k) Battery Charger/Generator 3.Engine Instrument Panel with the following items a) Starting switch with key or button. b) Lubricating oil pressure gauge. c) Water temperature gauge. d) RPM Indicator with hour meter. e) Battery charging Ammeter. 4. Safety Controls for Engine. a) Trip for low lubricating oil pressure. b) Trip for high water temperature. 5.Fuel pipe: Oil resistance flexible hoses of 20mm dia or nearest size MS pipe as per manufacturers standard, 6 Brush less Alternator a) Make : as specified in accepted list of materials b) Type - Self exited and self-regulated, brush less c) Capacity; 58.5 KVA/ 46.8 K W @ 0.8PF d) System of Voltage - 3 phase, 415 V, 4 wire system. e) Speed - 1500 rpm f) Voltage regulation band - +/-2.5% of rated voltage g) Frequency - 50 Hz h) Insulation - Class -F/H .The Alternator should confirm to IS 4722. Operation and service manual shall be provided.7.Fuel Tank Suitable size built in type integrated with the acoustic enclosure. Fuel connection shall be done as per standards 7. Battery. Suitable size built in type integrated battery with leads and terminals of appropriate AH capacity as per Manufactures requirement. 9. The DG shall be supplied along with specially designed company fabricated (to be fabricated in the same company from where the DG is delivered.)acoustic enclosure to meet the stingent MOEF/CPCB norms of 75 dB A @1m 75% load under free field condition 10. The standard Electric control panel integrated with acoustic enclosure comprising of the following. a) Rated MCCB with standby low set earth fault relay using CT in neutral conductorb) Digital Multi function meter with accuracy class 1 to read parameters such as KW,KVA, PF, voltage, Current Frequency etc: c) Digital type single function KWH meter with accuracy class 1, d) external source power (230V AC) battery charger e) Provision for connecting Auto start (AMF/ATS connection) 10.Exhaust Piping, Exhaust Piping shall be vent to the top of the nearest tallest building if required. If the pipe cannot be clamped/fixed to the building or any other structure of permanent nature necessary fabricated structures using channel section or angle iron sections of adequate mechanical strength, duly painted with 2 coats of Heat retardant aluminum paint shall be provided for the support of the exhaust pipe. (Additional piping will be measured excluding the standard length of pipe supplied by the manufacturer.) Arrangements for load testing shall be made available at the site or company by the selected agency at their own expense and the test should be conducted in the presence of department staff. The DG set should be provided with DLP period service , periodic maintenance as prescribed by the OEM including all consumable items like Engine Oil, Oil Filter, Air Filter, Coolant etc |
| 267 | OD41418/2026-2027:Supply, conveyance and filling of good grade Diesel fuel. |
| 268 | OD53265/2026-2027:Supply and Fixing 125 A, 415 V, 50Hz AC 4 Pole Automatic Transfer Switch with Controller and Enclosure and giving connections etc as required to fulfill the automatic operation of the DG set .(Model No.CK90161BSOO of M/S LK or equivalent). |
| 269 | OD41421/2026-2027:Supply and providing Cladding for 80mm Exhaust pipe using 10 inch dia aluminium cladding with 26 gauge aluminium sheet ,Rock wool ,chicken mesh etc as required. |
| 270 | OD42035/2026-2027:Supply and providing cladding for 100mm dia MS exhaust pipe using 50mm thick glass wool /mineral wool /rock wool density not less than 120Kg/m3 and aluminium cladding (0.6mm thick). |
| 271 | OD136810/2026-2027:Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:100mm dia |
| 272 | OD136811/2026-2027:Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:80mm dia |
| 273 | OD25573/2026-2027:Charges for Preparation of electrical /fire drawings in A3 sheet as per requirements for submitting electricalinspectorate/ fire department for approvals-First copy |
| 274 | OD25574/2026-2027:Charges for Preparation of electrical /fire drawings in A3 sheet as per requirements for submitting electricalinspectorate/ fire department for approvals- Additional copy |
| 275 | OD317056/2025-2026: Painting letters or figures of the following sizes with enamel paint as identification mark to SB, DB, panel board etc as required- 2.50 cm, 4 cm or 5 cm height |
| 276 | Lightning arrester(Electrical work) |
| 277 | 90.16.3.20:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)32 x 6 mm aluminium strip |
| 278 | 90.16.4.18:Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).32 x 6 mm aluminium strip |
| 279 | 90.16.4.5:Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).32 x 6 mm GI strip |
| 280 | OD136847/2026-2027:Supplying and laying 32 mm X 6 mm GI strip at 0.50 metre below ground including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 281 | OD23610/2026-2027:Supply and providing 200x145x95 or nearest size Sintex /Hensel Box for fixing testing joint for downconductors as required. |
| 282 | 1.20.4:Supplying and fixing of following sizes of steel conduit along with accessories in surface/recessincluding painting in case of surface conduit, or cutting the wall and making good the same incase of recessed conduit as required.40 mm |
| 283 | OD23612/2026-2027:Supply and fixing 25x6mm brass bolt with hexagonal/square head, nut and washeras required |
| 284 | 5.8:Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 285 | OD23614/2026-2027: Supply and fixing Suitable Support made out of Clay / porcelain (Bus Bar Support) for25x6 mm GI / Al Strip.with bolt nut etc |
| 286 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 287 | OD317032/2025-2026:Supply installation testing and commissioning of 1 Mtr Airterminal System: semi-hard(EAlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. a> OBO Type No. Rd10-ALU ( 5021 30 8 ). Accessories : System consist of Fang Fix Base . b> OBO Type No. FFIX-BASIS ( 5403 32 4 ). Fang fix Basis made of Polypropylene, lightning tested for 100 KA10/350 micro sec waveform. Vario Quick Connector as clamp c> OBO Type No.249 8-10ST Quick and easy mounting of interception tip using anchors. OBO Type No. 120 A /CAPE orequivalent make |
| 288 | Electrical Fire fighting (Electrical work) |
| 289 | 18.4.1:(a) Supplying, installation, testing and commissioning of electric driven900 lpm at 35m Head |
| 290 | OD317074/2025-2026:Supply,erection,testing and commissioning of Automatic Motor control panel for theelectric driven terrace pump, with 10/12.5 HP DOL starters, 40 A ,4 pole MCB isolator and contactors toensure auto and manual operation shall rated for motor HP. The panel shall include necessaryindicating lamps for the RYB phases,ammeters and volt meter with selector switch etc. The panel shall have Auto/ManualSelector switch. The panel shall be powder red colour and shall have provision forwall mounting with all accessories as required complete. |
| 291 | 18.8.7:Providing, laying, testing and commissioning of C class heavy duty GI pipe conforming to IS 1239, i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required.100 mm |
| 292 | 18.11.5:Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze or gun metal seat duly ISI marked complete with nuts, bolts ,washers ,gaskets conforming to IS 13095 of following sizes as required:100 mm dia |
| 293 | 18.14.5:Providing,installation,testing and commissioning of non-return valve of following sizes conforming to IS :5312 complete with rubber gasket, GI bolts , nuts, washers etc as required.100 mm dia |
| 294 | 18.17.1:Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.a) 20 mm nominal Internal dia water hose thermoplastic(Textile reinforced) type-2 as per IS:12585b) 20 mm nominal internal dia gun metal globe valve &nozzlec) Drum and brackets for fixing the equipments on wall.d) Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 m |
| 295 | 18.19.1:Supplying and fixing fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia M.S. Pipe connection conforming to IS 904 as required:2 way-100 mm dia M.S.Pipe |
| 296 | OD317070/2025-2026:Supply & erection of Glow Sign Board made of 3mm thick PVC foam board for each floor 16 & quot; x 16& quot; (Assembly Point sign board) |
| 297 | OD317071/2025-2026:SIGN BOARDS:- supply & installation of necessary Glow Sign Board made of 3 mm thick PVC foam board as per new fire station, Fire Exit passenger Lift, Electrical Duct ,Plumbing Duct, Main Stair, Floor level, Fire Lift in each floor and Pmp room |
| 298 | 16.8:Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required |
| 299 | 18.22:Providing and fixing of pressure switch in MS pipeline including connection etc as required: |
| 300 | OD317072/2025-2026:Supply and fixing Emergency Fire escape LED light with 2 nos LED lamps, 7 AH SMF battery Charging unit Exit sign display etc complete in MS enclousure. |
| 301 | OD317075/2025-2026:Supply, installation, testing and commissioning of Gun metal Air Release valve 20 mm dia as required |
| 302 | 17.5.2:CABLING & WIRINGSupplying & laying of 2x1.5 sq mm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 303 | OD134542/2026-2027:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp |
| 304 | OD134546/2026-2027:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size on wall surface as required. 3x10 sqmm (clamped with 1mm thick saddle) |
| 305 | OD134551/2026-2027:Providing and drawing 3.15 mm (10 SWG) copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 306 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 307 | 9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) |
| 308 | 9.1.7:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm) |
| 309 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 310 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 311 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 312 | 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 313 | 1.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module |
| 314 | 90.10.1.3:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface |
| 315 | OD24293/2026-2027:Supply and providing 4Kg ABC Fire Extinguisher cap filled with mono ammonium phosphate powder 50% confirms to IS 1409, stored pressure type, with pressure gauge, the discharge time 24 sec, controllable discharge mechanism, jet range 5 meters, average discharge is 90%, appliccable on A,B & C and electrically started fire, A rating-3A, B rating 21B, construction: deep drawn & co2 mig welded, EPDM rubber hose with both end aluminium clamped, internal coating-epoxy powder coating, external coating-pure polyster powder coating(UV resistant),brass forged valves with safety pin is of ss material, sheet metal thickness ISI approved. |
| 316 | OD137304/2026-2027:Supply and fixing (in appropriate location) of Fire emergency plan (colour) printed in photo paper of size A2 sand witched in clear acrylic sheet fixed using SS studs and other accessories complete as required as per the technical specification and conforming to IS 9457,IS 12349,IS 12407 |
| 317 | OD317078/2025-2026:Preparation of electrical /fire drawings in A3 sheet as per requirements in electrical inspectorate/ fire department approvals- First copy |
| 318 | OD317073/2025-2026:Copying charges of Electrical Drawing per A3 sheet additional copies |
| 319 | Lift Electrification(Electrical work) |
| 320 | OD137076/2026-2027:Supply, Installation, Testing and Commissioning of 13 passenger goods cum passenger machine room gearless lift conforming to IS 17900 . 1. Type of Lift: 13 Passenger capacity, Gearless 2. Load / Persons : 884Kg. / 13 persons 3. Rated speed :1 M/Sec. 4. Travel: 8 Mtr (Approx.) 5. No. of floor and entrance served: 3 stops and 3 openings 6. No. of floor served: Three floors 7. Method of control: Microprocessor based V3F with ARD system. 8. Size of lift well :1870 mm X 2500 mm 9. Car entrance: As per IS . 10. Leveling accuracy: As per IS 11. Car door opening: As per IS 12. Drive: Variable voltage variable frequency(V3F) 13. Operation: Simplex full selective collective control with ON/OFF switch 14. Construction of design and furnishing of car body work: Vandal proof Stainless steel (SS304, make: Tata/Jindal)finish cabinet with Scratch Proof Stainless steel door (sheet minimum thickness 1mm), Stainless steel mirror finish ceiling, Aluminum 3mm minimum thickness anti-skid flooring, fan with timer cut-off, push to talk, LED display, LED light, three side hand rails and floor announcement system. All buttons in car and all landings should have Braille sign. 15. Landing entrance: Automatic center/Telescopic opening Vandal proof stainless steel sliding door as per IS with provision for mechanical opening key for emergency with full length infra-red light curtains and half framed glass door(liminated toughened glass with a minimum thickness of 8mm ) 16. Call and position indicators: Up/down direction & position Dot Matrix LED indication shall be provided at all landings 17. Electric supply: 1) Light 230/50C/s single phase 2 wire system. 2) 415V 50C/s 3 phase 4 wire system. 18. Infrared door opening system: To be provided for entire length of the door 19. Automatic Rescue Device: Provide automatic rescue device with an electronic controller powered by maintenance free batteries with capacity for minimum four successive rescue operation at full load. The rescue operation should act within 10 seconds of power failure 20. Regulation :350V 450V (SMPS based) 21. Indication in the car: a) Car position b) Call indicator c) Door close/open push button d) Emergency stop button e) Flush mounted switch for fan and light f) Nonstop button g) Battery operated emergency lamp with rechargeable batteries. h) Battery operated alarm bell i) Intercom wiring with one master unit with two slaves j) Fireman's switch at main lobby i) Auto attendant control (inside the car) 22. Winding handle Manual winding handle for use in emergency. 23. Safeties a) Bidirectional Over speed governor(OSG), Progressive type safety gear b) Buffers c) Motor over load and under voltage protection d) Phase reversal protection e) Other safeties as per IS f) Single phase preventer g) Final limit switch 24. Leveling Automatic leveling at all landing as per IS. 25. Control panel: Control panel will be dust and vermin proof of sheet metal enclosure 26. Announcement System: To provide lift announcement system 27. Tests: At site test as per IS to be carried out and approval from Electrical Inspectorate before Handing over. 28. Scope of work:- a) Supply of lift materials b)Minor civil works such as removal of temporary brick work in the lift entrance without affecting the building structure, finishing/ altering civil works in lift entrance/ pit by providing brick work & plastering if necessary including minor civil works such as construction of buffer block in the pit machine foundation in the machine room, necessary core cutting , cutting pockets and grounding brackets for the guide rails, grouting boxes for control units, correction of wall opening in the front side in plastering c) Scaffolding d) Door frames e) Supporting steel (machine and rope ending point support should extended to existing well wall side using suitable I/C section channels as per the direction of department staff) f) Temporary electric supply for installation of lift. Electric supply for testing and commissioning of lift is to be arranged by the firm on their own account. g) Intercom facilities with one master and two slaves h) Battery operated alarm i) Obtaining Scheme approval as well as energization Certificate from the electrical Inspectorate including preparation of necessary drawing for the same. inclusive of necessary fee to the Inspectorate and first year insurance as per new lift rule by the firm for which no refund will be made from the department including taking insurance for one year as per new lift rule. j) Supply of booklets with complete details of maintenance schedule and control diagram. k) Giving training to department staff for attending trouble shooting 28.Unintentional car movement protection 29. Guarantee: Company shall carry out free maintenance and service during warranty period which also includes a) Cleaning lift equipment b) Lubrication of all moving parts c) Replacing of lubricating oil when required d) Checking and adjusting contacts e) Replacing fusible item alarm etc. f) Recharging batteries in case of drain/ renewing batteries g ) Replacing /rewinding of all defective parts of the lift including motors |
| 321 | CCTV (Electronics Work) |
| 322 | OD347145/2025-2026:SITC of 4MP Fixed Bullet WDR Weather proof IP camera with following features:- IR range: 50m, Image sensor - 1/2.7 inch 4MP PS CMOS , Lens-3.6mm Fixed, Resolution- Max. 4MP (2688 × 1520)@1–25/30fps/ (2560×1440)@1–25/30fps, WDR(120dB), Day/Night(ICR), Video compression: Insta-stream, H.265, H.264, H.264H, H.264B, MJPEG, Stream Capability-min 2 stream, S/N Ratio- >58 dB, Shutter Speed Auto/Manual 1/3 s-1/100,000 s, built in mic, POE, Motion detection, IP67, ONVIF compatible , Including Camera fixing accessories, giving connections and all other charges, Certificates-STQC, ISO9001, CE, FCC and RoHS, BIS Warranty: 5 years Approved Make: CP plus/ Honeywell/Matrix |
| 323 | OD347146/2025-2026:SITC of 4MP Vari-Focal Bullet WDR Weather proof IP camera with following features:- IR range: min 50m, Image sensor - 1/2.7 inch 4MP PS CMOS , Lens-2.7~13.5mm motorized, Resolution- Max. 4MP (2688 × 1520)@1–25/30fps/ (2560×1440)@1–25/30fps, WDR(120dB), Day/Night(ICR), Video compression: Insta-stream, H.265, H.264, H.264H, H.264B, MJPEG, Stream Capability-min 2 stream, S/N Ratio- >58 dB, Shutter Speed Auto/Manual 1/3 s-1/100,000 s, built in mic, POE, Motion detection, Ik10 rated, IP67, ONVIF compatible , Including Camera fixing accessories, giving connections and all other charges, Certificates-STQC, ISO9001, CE, FCC and RoHS, BIS Warranty: 5 years Approved Make: CP plus/Honeywell/Matrix |
| 324 | OD280087/2025-2026:Supply and installation of Screw-In type Outdoor Square Junction Box for CCTV Cameras fixation with Ingress Protection Code of IP65/67 having 4 Inch x 4 Inch x 2.4 Inch or in adequate size of Waterproof Polyvinyl Chloride with all its Cable Gland and screws. |
| 325 | OD291006/2025-2026:Supply and Installation of Wall Mount Rack having the features of 19 inch 9U, 550mm wall mount Rack with Front Glass door and having all hardware mounting accessories, provision for Lock and Unlock, ACDB 4 ports minimal, 1U closed cable manager, cooling fan etc. and apart from related electrification as well. Approved Make- Netrack/Valrack/HCL/ Schneider/President |
| 326 | OD291148/2025-2026:Suppy and installation of 19 inch, 17U, 600mm , glass trolley type rack with ACDB greater than 4 ports, in 2 closed cable manager , AC adapters with min 8 socket, cooling fan etc.,min three cantilever shelf. Approved Make- Netrack/Valrack/HCL/ Schneider/President |
| 327 | OD291179/2025-2026:24 Port Gigabit managed PoE+ Switch with 2 SFP ports, 190W PoE budget, 24 10/100/1000 Mbps auto-sensing Gigabit Ethernet, 2 combo Gigabit copper/SFP slots, 56 Gbps bandwidth, 16K MAC address database size, with rack mounting kit etc. Operates On AC 110/220V, Efficient Delivery of Power according to IEEE 802.3a. Suitable for connecting the given IP Cameras. Certifications :- CE, FCC,EN 55024 , Approved Make: Netgear/Cisco/Allied Telesis/ Brocade, HP.warranty -5 year. |
| 328 | OD280075/2025-2026:Supply and installation of Modular type unloaded Patch Panel with rear cable organizer made of cold rolled steel, powder coated, front labelling Facility and suitable for RJ 45 CAT 6/CAT6A Keystones and labelling as required. Approved Make: Molex, Honeywell, Commscope, Norden. |
| 329 | OD280074/2025-2026:Supply, termination, testing, and commissioning of UL Listed, ETL verified CAT 6 Keystone Jack with dust protection, suitable for 22- 24 AWG bare copper conductor, Minimum 500 insertion cycles and 100 re terminations, as per TIA/EIA 568-B colour code conforming to the standards ANSI/TIA-568.2-D , ISO/IEC 11801, IEEE 802.3, ISO/IEC 60332-1,and RoHS Complaint. approved Make: Molex, Honeywell, Comscope, Norden. |
| 330 | OD280073/2025-2026:Supply, installation, testing, and commissioning of UL Listed, ETL verified LSZH 0.5 meter CAT 6 UTP Patch Cord. Approved Make: Commscope, Molex, Panduit, R and M, Systimax. |
| 331 | OD293775/2025-2026:Supply, installation, testing, and commissioning of UL Listed, ETL verified LSZH 1 meter CAT 6 UTP Patch Cord. Approved Make: Commscope, Molex, Panduit, R and M, Systimax. |
| 332 | OD280070/2025-2026:SITC of 32 Chanel project series Network Video Recorder, Should support Resolution:- greater than equal to 12 MP IP Camera, Network Bandwidth incoming -384, Insta-stream/H.265/Smart H.264+/H.264/MJPEG codec decoding,, Recording play back quality: 16 ch play back simultaneously, Recording resolution up to 12MP, Recording mode: support manual, Auto, Motion detection, Alarm, trigger record mode, Operation way: Mouse, local Login: Username and password, Support 2 SATA HDDs up to min 16TB Each, 2 USB Ports (1 front USB 2.0 port, 1 rear USB 3.0 port), HDMI/ VGA Heterogeneous video output, Supports intelligent analytics such as facial recognition, human detection, vehicle detection, License plate recognition, perimeter intrusion, and line crossing statistics , product must comply with NDAA compliance, Certification: BIS,CE,FCC,ROHS ,ISO 9001:20015 ,Warranty:5 years, Approved Make: CP plus/ Honeywell/matrix |
| 333 | OD297601/2025-2026:Supply and installation of Enterprise class Video Surveillance Hard Disk of 8TB. Approved Make: Western Digital/Seagate |
| 334 | OD297620/2025-2026:Supply and installation of 6TB SATA surveillance Hard disk drive to be fixed in the NVR. Approved Make : WD /Seagate Barracuda- having three year warranty. |
| 335 | OD280153/2025-2026:Supply and installation of 5 mtr HDMI cable for connecting the monitor and NVR. Make: Honeywell, Belkin, BlueRigger, Belden |
| 336 | OD280071/2025-2026:Supply and Installation of wireless Mouse with USB extender cord.(Approved Make:-Dell, Logitech,HP) |
| 337 | OD280076/2025-2026:Supply and installation of 32 inch HD CG-24 x 7- LED Color Television having Audio/Video in and out, HDMI, USB connectivity with full function remote controller and wall mounting kit etc. having 5 year warranty (Approved Make: LG, Samsung and Panasonic ). |
| 338 | OD291233/2025-2026:Supply, drawing. testing and commissioning of UL certified and ETL verified 23 AWG bare copper conductor UTP 4 pair un-armoured CAT 6 cable with HDPE Insulation Material and LSZH Outer Jacket, conforming to the standards ANSI/TIA-568.2-D, ISO/IEC 11801, IEEE 802.3, ISO/IEC 60332-1,ISO/IEC 61034-2,ISO/IEC 61754-2,Colour Code as per TIA/EIA 568-B, RoHS Compliant, transmission performance tested up to 500 MHz or better and Insertion Loss/ Attenuation: 33 dB/100m or better at250 MHz in the existing conduit as required, Approved Make: Molex , Delton Actassi, Belden, Comscope, Panduit |
| 339 | OD280088/2025-2026:Supply and Installation of 100 x 50 mm PVC Cable Management System with base and lid along with the all necessary accessories such as External angle 90 degree, Flat angle 90 degree, Internal angle 90 degree, Internal coupler, Flat cross, End cap,, Flanged coupler, Joint cover, Cable retainer, wall plate for internal angle etc. conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required. (Make: Honeywell equivalent) |
| 340 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 341 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 342 | OD280072/2025-2026:Supply , installation, testing and commissioning of 1KVA Line interactive UPS (it could be greater in rating of KVA and DC Volt ) UPS, 26AH battery pack having sufficient back up power 312VH. Approved make: Numeric, Microtek, Hykon |
| 343 | OD291228/2025-2026:Permanent Warning Sign board that indicates -These premises are under CCTV Surveillance - and it should have minimum sufficient size and quality. |
| 344 | Common Announcement System (Electronics Work) |
| 345 | OD291046/2025-2026:Supply and installation of 8W PA wall speakers with mounting bracket and all hardware accessories having Power taps : 8/4/2W on 100V, low impedance: 8 ohms, Frequency Response : 60-15,000 Hz , Sound pressure level :92dB, Warranty -5 years, Approved Make and Model : Ahuja WSX-681T/equivalent. |
| 346 | OD291074/2025-2026:Supply of good quality Wooden Rack having minimum 700mm width and 600mm depth, and having sufficient no. of partitions, door and lock with suitable size to accommodate Amplifiers and Accessories, fitted with AC Power Distribution Box having minimum 4 Nos. of ISI standard 3 pin plug points and 5m cable length. |
| 347 | OD294530/2025-2026:SITC of 250W rack mountable Amplifier with features: 6 mics and 2 AUX inputs, 300W Max and 250W RMS, Frequency response-50Hz to 15KHz +/_ 3dB, Bass and treble control, Output-4ohm, 8ohm,70V and 100V, operating at 24V DC and AC, MP3 player with USB, SD and MMC card reader and remote controller. Warranty: 5 Years, Approved Make: Ahuja SSA-250 DP. |
| 348 | OD280116/2025-2026:Supply and installation of wired paging Microphone having Frequency Response 50-15,000Hz, Sensitivity 2.2mV/Pa, Impedance 500 ohm . With on/off switch, stand mount base, XLR connector and 6m twin core shielded low noise cable. Approved Make and Model : Ahuja AGN-500 or equivalent |
| 349 | OD280115/2025-2026:Supply and installation of Microphone stand that employ sturdy mechanism ensuring trouble free movement and positioning of microphones. Approved Make and Model : Ahuja ATS-5 or equivalent |
| 350 | OD280110/2025-2026:Supply of 10 meter low noise shielded 2 core Mic cable with 3 pin XLR male-female connector. |
| 351 | OD291086/2025-2026:Supplying, installing, testing and commissioning of Smart Acoustic Automatic School Bell System suitable for schools and educational institutions, complete in all respects, including high-output acoustic speaker with minimum 150 metre audible range, combo acoustic and electric bell arrangement with potential-free contact for external bell/hooter operation, Wi-Fi/Bluetooth-enabled controller with Android mobile application support, built-in non-volatile real time clock with lifetime memory backup, soft-touch keypad for manual operation, LCD display for easy programming and monitoring, support for MP3 audio/vocal file playback, emergency tone generator with manual bypass switch, facility for user-programmable bell schedules for periods, short breaks, recess, assembly, etc., provision for minimum 20 bell events per day, capability to set different bell durations and tones (minimum five types) for identifying different school activities, permanent retention of all programmed data and RTC during power failure without loss of settings, complete with mounting accessories, internal wiring, interconnections, testing, demonstration, and commissioning, as required. Warranty-5 years. |
| 352 | OD280108/2025-2026:Supply and drawing of standard graded speaker cable(2 core*1.5 sq.mm) through the existing conduit and giving connections as required. Approved Make: MX/Havells/ Finolex/ RR Kabel |
| 353 | OD291047/2025-2026:Supply and installation of 30W PA Dual Sound Projection speakers with mounting bracket and all hardware accessories having Power taps :30W/20W/10W/5W , low impedance: 330ohm, Frequency Response :120Hz-15KHz , Sound pressure level : 94dB , Warranty -5 years, Approved Make and Model : Ahuja SP-6305TD/ Studio master. |
| 354 | OD294540/2025-2026:SITC of 120W rack mountable Mixer Amplifier with digital player with features: 5 mics and 2 AUX inputs, 160W Max and 120W RMS, Frequency response-50Hz to 15KHz +/_ 3dB, Bass and treble control, Output-4ohm, 8ohm,16ohm 70V and 100V, operating at 24V DC and AC, MP3 player with USB, SD and MMC card reader and remote controller. Warranty: 5 Years, Approved Make: Ahuja SSB-120 DPM/ Equivalent |
| 355 | OD294531/2025-2026:SITC of 75W rack mountable Mixer Amplifier with digital player with features: 4 mics and 1 AUX inputs, 100W Max and 75W RMS Frequency response-50Hz to 15KHz +/_ 3dB, Bass and treble control, Output-4ohm, 8ohm,16ohm at100V, operating at 24V DC and AC, MP3 player with USB, SD and MMC card reader and remote controller. Warranty: 5 Years, Approved Make: Ahuja DPA-770 M/ Equivalent |
| 356 | LAN at School (Electronics Work) |
| 357 | OD293733/2025-2026:Supply and Installation of 6U Wall Mount Rack having the features of, 6U x 550 W x 450 D, Front Glass Door (tinted, Toughened) with Lock & Key, 2 pairs of 19 inch Mounting Rails with U-Marking, Welded Side Walls With Metal Engraved Logo, Standard Accessories, 1U Cable Manager, Hardware Packet, 4 Socket 5 Amp minimal. PDU, Roof Mounted Fan Unit / 90 CFM /230V AC, Approved Make: HCL, Valrack, Netrack, President, Schneider. |
| 358 | OD280126/2025-2026:Supply and installation of 24 port Gigabit unmanaged ethernet rack mountable switch with 24 x 10/100/1000 Gigabit ports , Switching Capacity-48Gbps, Maximum Forwarding Rate 1,448,000 pps,MAC Address Table Size-8K, with all necessary accessories, Warranty-5 years, Approved Make-Netgear/ Cisco/HP |
| 359 | OD280140/2025-2026:Supply, Installation, Testing and Commissioning of Cat6 Information Outlets with face plate, Gang box etc having 1000 Mbps with spring shutter front access for connecting nodes on with concealed mounting box consisting of MS cable store, Key stone Jack and having ETL 4 Channel Connector Tested, - Contact Resistance: <20MΩ, Insulation Resistance: >100MΩ Min, - RoHS Compliant, Approved Make: PANDUIT/COMMSCOPE/MOLEX/NEXANS/LEGRAND |
| 360 | OD280138/2025-2026:Supply, installation, testing, and commissioning of UL Listed, ETL verified LSZH 3 meter CAT 6 UTP Patch Cord. Approved Make: Commscope, Molex, Panduit, R and M |
| 361 | OD280139/2025-2026:Supply, installation, testing, and commissioning of UL Listed, ETL verified LSZH 2 meter CAT 6 UTP Patch Cord. Approved Make: Commscope, Molex, Panduit, R and M Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 9 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender