Defence Statutory Bodies & Commissions/Committees Closing in 5 days TDR #57921752

Tender For Special Repair To Bldg No. P-467 (Attach Line 3) Hq Cif(K) Force At Sharifabad Mil Stn Under Age (I) Cif (K)

Issued by Statutory Bodies & Commissions/Committees · Srinagar, Jammu and Kashmir
Tender Value
6.59 Lakhs
Estimated cost
Bid Submission
05 Nov 2026
5 days left
EMD
13200
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Srinagar → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Special Repair To Bldg No. P-467 (Attach Line 3) Hq Cif(K) Force At Sharifabad Mil Stn Under Age (I) Cif (K)

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 29-Oct-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 05-Nov-2026

BOQ

Name of Work:- SPECIAL REPAIR TO BLDG NO. P-467 (ATTACH LINE 3) HQ CIF(K) FORCE AT SHARIFABAD MIL STN UNDER AGE (I) CIF (K)
Sl. No. Item Description
1Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering, complete all as specified and directed by the Engineer-in-Charge.
2S&F Pre-painted galvalume aluminum zinc coating GI based corrugated profile steel sheet 0.50mm thick of colour as approved by AGE(I), having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed by the Engineer-in-Charge.
3S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of colour as approved by AGE(I), having tensile strength of 550 Mpa as in roof covering/cladding to ridges, valley gutters etc. fixed with self tapping screws, complete all as specified and as directed by the Engineer-in-Charge.
4Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed by the Engineer-in-Charge.
5Non skid ceramic coloured tiles 1st quality 7 to 8mm thick, (square/ rectangular), area of each tile exceeding 0.18sqm, but not exceeding 0.38sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over and including 15mm thick screed bed or bedding layer in cement mortar 1:6, complete all as specified and as directed by the Engineer-in-Charge.Note: Colour and shade of tiles shall be approved by AGE(I) and contractor shall not have any claim whatsoever on this account.
6Non skid ceramic coloured tiles 1st quality 7 to 8mm thick, (square/ rectangular), area of each tile exceeding 0.06sqm, but not exceeding 0.11 sqm as in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over and including 10mm thick rendering in cement mortar 1:4, complete all as specified and as directed by the Engineer-in-Charge.Note: Colour and shade of tiles shall be approved by AGE(I) and contractor shall not have any claim whatsoever on this account.
7Taking down cement plastering on stone wall/brick wall etc including racking out of joints hacking for key scrubbing down with water etc
8M&L 15mm thick rendering on wall in CM 1:6 on brick/concrete surface and finishing the surface even and smooth with out using extra cement.
9M&L 15mm thick rendering on wall in CM 1:4 on brick/concrete surface and finishing the surface even and smooth with out using extra cement.
10Material and labour for preparation of new plastered surfaces on walls and applying two coats of oil bound distemper over 3mm thick wall care putty complete all as specified.
11M&L for preparing new plastered surfaces of walls for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed.
12S&F in repairs harrison rail/curtain rails, mild steel chromium plated with fixing brackets , stops, rollers etc as spd and directed.
13Taking down chowkats or frames with shutters (without taking off shutter from the frame) of any description alongwith fittings n.exc 1.5sqm each
14Taking down chowkats or frames with shutters (with out taking off shutter from the frame) of any description alongwith fittings exc 1.5sqm n.exc 4 sqm each
15S&F 2nd class hard wood Plain , solid , straight chowkats and frames, wrought , framed rebated on the solid , rounded or chamfered put together with glue pinned at joints, supplied and fixed.
16S&F 35 mm thick 2nd class hard wood Plain framed, panelled shutters(any number of panels), with panel of timber flat on both sides (feather edged) or 12 mm thick BWP of veneered particle board medium density wood commercial face veneers fixed to chowkats.
17S&F 2nd class hardwood glazed and skelton door shutters 35 mm thick divided into squares open rebated and prepared to receive glass, gauge etc edges of framing plain, chamfered, rounded tfitted with mltred beads for securing glass etc, size of members as specified in SSR Pt 1 section 8 clause 8.20 (b) supplied and fitted to chowkats with plain, chamfered or rounded mited and rebated bars any numbers.
18Supply & fix Steel windows 1.25 mm thick Box type (primer coated) ERW hollow ‘P’ section of size 60mm x 25mm single rebated comprises of gauged skeleton shutter EWR Sec 50mmx20mm and 1mm thick and two open able leaf consisting two Nos sash bar of ‘T’ section 20mm x 3mm complete welded to frame with one vertical mullion of EWR box type ‘T’ section of size 60mmx25mm and 1.25mm thick including cuttings holes and making good dismantled portion in PCC (1:2:4) type B1 using 20mm graded stone aggregate. Four Nos for each window including following fittings welded to framed shutter :- (a) Holdfasts 150mm long 12mmx3mm made to shape per window -04 Nos, (b) Handle of Z Sec 20mmx25mm, 100mm long per leaf-01 No, (c) MS tower bolt 150mm long per leaf -02 Nos, (d) ‘Z’ sec 20mm x 25mm, 100 long stopper per leaf -01 No, (e) Cleat 55 mm long of hollow square 15mmx20mmx63mm welded to hinges per leaf -01 No, (f) MS pintle hinges of size 75mmx12mm per leaf -02 Nos, (g) Fabrication and fixing arrangement as per drawing No CESZ/TD/1018/2011, Sh 1/3 to 3/3 .
19All as per item No. 18 above here in before but glazed, complete all as specified & directed.
20S&F framed work such as grills & gates, gratings with ends of bars shouldered on forged in spickes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, rallings, framework of water tanks and similar work conforming to Fe 410 (or) Fe-310-0
21S&F 4mm thick, plain sheet glass, selected quality and glazing with oil putty in squares exc 0.5 sqm in each pane complete
22S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and avg erage with aperature 1.18 mm fixed with tinned tacks, or galvanised wire staples.
23S&F aluminium alloy anodised sliding door bolts 250 mm long with hasp, staple (bolt type)and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded sections as specified.
24S&F aluminium anodised barrel tower bolts of extruded section 150mm long all as specified
25S&F Butt hinges, medium weight cold rolled 100mm size ISI marked.
26S&F Extruded aluminium alloy handles fabricated type anodised 150mm size
27S&F Extruded aluminium alloy handles fabricated type anodised 100mm size
28S & F 300 mm mild steel ordinary rat tail rod pattern springs including roller and roller plate complete as fixed in repairs.
29Dismantling of wall and ceiling boards ( fibre, pulp, insulation, etc ) or insulation boards/slabs, blankets , any thickness including cover fillets complete all as specified
30M&L for GI frame work size of grid 605 x 605 mm for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from sofit at approx 900 mm centre to centre with GI cleat and steel expansion fasterner with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips acress the intermediate channel at 457mm centre to cnetre including hangers 6mm dia.GI (upto 1200mm length) adjusting level fixed tp roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm ling and expansion hold fasterner 12.5mm dia 40mm long including 8mm thick gypsum board of size 600mm x 600mm as in ceiling fixed on GI frame work, complete all as specified and directed by Engineer-in-Charge.
31Dismantling boarding, fibre or pulp, insulation etc. in insulation boards slabs, blankets any thickness incl cover fillets all as specified and directed.
32S&F 15mm thick 2nd class soft wood clean sawn boarding as in eveas board fixed with nails in any situation complete all as spd and directed by engr-in charge.
33M & L for applying two coat of synthetic enamelled paint over one coat of pink primer including preparation of new wood surfaces of any description not otherwise described over 10 CM girth or width all as directed by the Engr in charge
34M & L for applying two coat of synthetic enamelled paint over one coat of red oxide primer including preparation of new steel surfaces of any description not otherwise described over 10 CM girth or width all as directed by the Engr in charge
35Demolition of cement concrete in ground floor and paving n.exc 15 cm thick, below or above ground level complete .
36M&L 75mm thick PCC 1:3:6 type C2 (using 40mm graded stone aggr) as in plinth protection/path finishing the surface even and smooth without using extra cement complete all as specified and directed.
37M&L for 100 mm thick cement concrete type C-2, 1:3:6 as in plinth protection with saucer drain, complete all as specified.
38Demolition of brick or stone masonary built in cement mortar complete
39M&L brick work with sub-class 'B' bricks, straight or curved on plan exceeding 6 M mean radius built in CM 1:4, complete all as specified.
40Material and labour for PCC type D2 (1:4:8) using 40mm garded stone aggragate as in foundation ,filling etc complete all as specified and as directed.
41M&L machine pressed precast coloured concrete interlocking paver blocks any shape and size conforming of IS 15658: 2006 of 60mm thick , M-35 laid and jointed with grey cement and pigment, complete all as specified and directed.
42M & L 20mm thick Sand filling under floors or in foundations including watering and consolidation
43M&L for Cement concrete 1:2:4 type B0 (12.5mm graded aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed
44Taking down old unservicable point wiring including fittings & fixtures and making good of the surface to match with the existing including touch up of paint/white wash to the disturbed surface of the wall / ceiling,etc., complete all as specified and directed by Engineer- in-charge.
45M&L for point wiring with 1.5 sqmm (nominal cross section area) PVC insulated unsheathed single core copper cable working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in including PVC rigid non metalic 25 mm dia or PVC casing caping including MS sunk box 3 mm thick hylum sheet top cover fixed by means of brass machine screw and cap washer including size 1.5 sqmm (nominal cross secrional area) PVC insulated unsheathed single core multistranded copper conductor cable as earth continuty conductor connected to main switches/DBs or common earth dolly complete all as specified and as directed for one light point or one fan point controlled by one one way switch with cable 1.5 sqmm size.
46All as per item No 45 above but one 3/5 pin switch socket 5/6 Amps on same board.
47All as per item No 45 above but one 3/5 pin switch socket 5/6 Amps on Independent board.
48All as per item No 45 above but one 3/5 pin switch socket 15/16 Amps on same board with using 2.5 sqmm PVC insulated multi stranded copper conductor with 2.5 sq mm earth continuity conductor for same board.
49All as per item No 48 here-in -before but using 4 sqmm PVC insulated multi stranded copper conductor with 4 sq mm earth continuity. conductor for independent switch socket out let 5 pin 5/15 Amps point.
50M&L for replacement of sub main wiring with two run of 6 Sqmm single core, PVC insulated but unsheathed multi-stranded copper conductor, 1100 volts grade drawing through and including PVC conduit of 25 mm dia concealed type with all accessories and 6 sqmm PVC insulated but unsheathed multi-stranded copper conductor cable as earth continuity wire including taking down old submain wiring complete all as specified and directed. Note: Two run of PVC cable with one run of PVC conduit and one run of PVC earth wire shall be measured and paid as one length only.
51Supply and fixing modular switch piano flush type single pole one way 6 amps.
52Supply and fixing modular switch piano flush type single pole one way 16 amps.
53Supply and fix modular socket 6 Amp, 2/3 pin combined 2 module.
54Supply and fix modular socket 16 Amp, 2/3 pin combined 2 module.
55Supply and fix modular fan regulator 120w - 2 module.
56Supply and fixing PVC batten/angle holder including connection etc. as required.
57S&F 3 pin 5 Amp ceiling rose on the existing junction box/wooden block including connection as required.
58Supply and fix white cover plate 4 module.
59Supply and fix white cover plate 6 module.
60Supply and fix metal flush box 4 module.
61Supply and fix metal flush box 6 module.
62Supplying and fixing in replacement factory made sheet metal enclosure (double door) shutter type for MCB DB SPN 8 way with 200 Amps rated bus bar, neutral link,earth bar complete.
63All as per item No 62 here-in-before but 4 way, Double door.
64S&F MCB SP 5 to 32 Amps 240 Volts. ,'C' curve of breaking capacity 10 KA all as specified and directed by Engineer-in-Charge.
65S & F MCB SPN 40 to 63 Amps 240 Volts, C' curve of breaking capacity 10 KA all as specified and directed by Engineer-in-Charge.
66M & L for earthing complete with GI earth plate electrode 600 x 600 x 6.5 mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron strip 32x6 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part-I and including necessary excavation and earth work in any type of soil, removal and refilling of soil and funnel with wire mesh and GI watering pipe 20mm dia, Chamber in PCC 1:3:6, type C1 using 20mm graded stone aggregate and 40mm thick cover in RCC 1:2:4, type B1 using 20mm graded stone aggregate and reinforced with 8mm dia TMT bars at 150mm c/c on both ways, handle with 16mm dia round bars and 15mm dia GI pipe upto 7.5m for protection and connected to earthing test point all as specified or indicated including testing on completion. Note:- (i) GI earth lead wire upto 7.5m shall be measured and paid. (ii) PCC chamber shall be provided 50cm away from tthe plinth of building.
67S&F LED light fittings 20 watt, 220V, 220 V, AC decorative box type with driver (warm/white), holder, including LED tube light connecting up with three core flexible copper conductor cable of suitable size from celling rose complete.
68Supply and fix LED light fitting 1X9W/1X10W bulkhead lumminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.
69Note :- An amount of Rs. 16,755.60 on account of credit schedule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57921752
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 6.59 Lakhs
LAST DATE 05-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair To Bldg No. P-467 (Attach Line 3) Hq Cif(K) Force At Sharifabad Mil Stn Under Age (I) Cif (K)
Basic Detail
Tender No AGE (I) CIF (K) - 69/2026-27
Bidding Type Tender
Location
City Srinagar
State Jammu and Kashmir
Key Dates
Publish Date 29 Oct 2026
Submission Date 05 Nov 2026
Open Date 07 Nov 2026
Finance
Tender Value 6.59 Lakhs
Tender Fee 500
EMD 13200
Exemption Not Available
Document List
BOQ_888996.xls
ef7b8c47-1b13-456c-a99d-48351aa8c611.html
Tender69.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 05, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 5 days
Nov 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Nov 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_888996.xls

html

ef7b8c47-1b13-456c-a99d-48351aa8c611.html

pdf

Tender69.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender