Tender For maintenance of Gangajal (Two Year Repairing Of D.G. Sets And Other miscellaneous Work At Gangajal Ugrs In Sector-65, 72, 51, 118 (M1), 69 (M2 And M3) Noida
Tender Value
81.26 Lakhs
Estimated cost
Bid Submission
21 Oct 2026
3 days left
EMD
1.91 Lakhs
Bank guarantee accepted
Document Fee
2832
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ghaziabad → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for maintenance of Gangajal (Two Year Repairing Of D.G. Sets And Other miscellaneous Work At Gangajal Ugrs In Sector-65, 72, 51, 118 (M1), 69 (M2 And M3) Noida
BOQ
| Sl. No. | Item Description |
| 1 | 400 KVA DG Set (08 Nos)Controler : Acluator |
| 2 | Engine control Unit (EMS907) |
| 3 | Lub. Oil pressure sensor with switch |
| 4 | Excilor starter assembly- Tex 5 |
| 5 | Rotating Rectifier Assembly with 6 Nos. |
| 6 | 24 V DC Relay Board 2CH. OEN Make Relay( 70 Amp) |
| 7 | Engine control Panel Assembly for K- Series |
| 8 | Switch for Radiator water level |
| 9 | Coupling Disc (Part no. AG3050700000) S/F |
| 10 | Air Cleaner Primary Element for 8K15TA Engine |
| 11 | Air Cleaner Safety Element for 8K15TA Engine |
| 12 | Fuel Filter Assly |
| 13 | Fuel Pre Filter Assly |
| 14 | Anti Vibration Mount Type 400 for 300 650 G |
| 15 | Charging Alternator |
| 16 | Water pump Asembly |
| 17 | Radiotor Cap(320/400 KVA) |
| 18 | Turbo Charger Assly |
| 19 | Lub. Oil Filter Cartige |
| 20 | Labour Charges( Elect & Mech.) |
| 21 | S/F front type and Tube. |
| 22 | S/F of Rear Tyre and Tube |
| 23 | S/O Battery 12V PM 20000 Prestolide make basisc price 12269.00 + Acid Filling 150/- = 12419.00 ( For 9 Nos) |
| 24 | 250 KVA DG Set (1 Nos) |
| 25 | Injector(Mico No. 94 30032 326) |
| 26 | Cylinder Head Gasket(1.25mm) |
| 27 | Rocker cover (Finish) |
| 28 | Charge air manifold |
| 29 | joint for exhaust manifold |
| 30 | Water pump sub. Assembly |
| 31 | Alt(Aotolek.24 V, 40A) |
| 32 | Starter (Delco Remy 42 MT) |
| 33 | Spin on filter for lubricating oil |
| 34 | Antivibration mount RR 400 Hight |
| 35 | Rubber house for main air pipe 100 |
| 36 | Hose(200 KVA yound radiator) |
| 37 | Assly of stop solenide24 vdc |
| 38 | Hose (Radiator inlet 50 ID) |
| 39 | Hose (Radiator outlet 60 ID) |
| 40 | Anti Vibration |
| 41 | Fan drive pully assembly |
| 42 | Starter ring |
| 43 | Radiator-AL CAC 200 KVA |
| 44 | Main Element for 250 KVA Air |
| 45 | Safety Element for 250 KVA Air |
| 46 | Fuel pump |
| 47 | Feed Pump |
| 48 | Magnetic pick up 16X1.5 threading |
| 49 | Terminal Block S/F KG alternator |
| 50 | Excitor Rotor Assembly tex 2.1 S/F |
| 51 | Excitor starter Assembly tex 2.1 |
| 52 | Rotating Reefifer Assembly |
| 53 | Plastic Fan 30'' |
| 54 | Diesel Filter |
| 55 | Coolent (8X30 + 1X20= 260 Ltr) (For 09 Nos) |
| 56 | Mobil Oil (8X55 + 1X35= 475 Ltr) ( For 09 Nos) |
| 57 | Labour charges (E & M) |
| 58 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.With cement mortar 1:4 (1cement: 4 Fine sand) |
| 59 | Finishing walls with textured Acrylic Smooth exterior paint of required shade Old work (One or more coat applied @ 1.82 ltr/10 sqm). |
| 60 | Providing Wall Putty on old surface with approved quality material of Berger/ JK/ Birla of similar make 2 coats. |
| 61 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work |
| 62 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-Charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-Charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in Charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. |
| 63 | c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-Charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-Charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge: With average thickness of 120 mm and minimum thickness at khurra as 65 mm |
| 64 | Manufacturing, supplying and fixing retro reflective overhead signage boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type - III of ASTM-D-4956-01 as approved by Engineer-in Charge, letters, borders etc. as per IRC: 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, |
| 65 | including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium sheet including appropriate priming coat The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the Engineer-in-Charge.(Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment).Overhead informatory road signage |
| 66 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. n gratings, frames, guard bar, ladder, railings, brackets, gates and similar works Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 08, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysOct 22, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender