Housing Urban and Rular Development Government Departments Closing in 0 days TDR #57920906

Tender For Upgradation, Renovation And Repair Of Girls Hostel At Govt. Polytechnic For Women Srinagar (Old Block).

Issued by Government Departments · Budgam, Jammu and Kashmir
Tender Value
1.25 Crore
Estimated cost
Bid Submission
15 Oct 2026
0 days left
EMD
2.51 Lakhs
Bank guarantee accepted
Document Fee
2600
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Budgam → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Upgradation, Renovation And Repair Of Girls Hostel At Govt. Polytechnic For Women Srinagar (Old Block).

BOQ

Name of Work:- Upgradation, Renovation and Repair of Girls Hostel at Govt. Polytechnic for Women Srinagar (Old Block).
Sl. No. Item Description
1Removing dry or oil bound distemper, water proofing cement paint andthe like by scrapping and sand papering and preparing the surface smoothincluding necessary repairs to scratches etc. complete.
2Repairs to plaster of thickness 12mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape raking outjoints and preparing and plastering the surface of the walls completeincluding disposal of rubbish to the dumping ground within 50 meters lead With cement mortar 1:4 (1 cement : 4 fine sand).
3Providing and applying white cement based putty of specified thickness,of approved brand and manufacturer, over the plastered wall surface toprepare the surface even and smooth complete. 2 mm thick
4Distempering with 1st quality acrylic distemper (ready mixed)havingVOC content less than 50 gms/litre,two or more coats on new work ofapproved manufacturer, of required shade and colour complete as permanufacturer’s specifications Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.
5Finishing walls with acrylic smooth exterior paint of required shade onNew work (Two or more coats applied @ 1.67 liter/10sqm over andincluding priming coat of exterior primer applied @ 2.20kg/10sqm).
6Removing old paint from metallic / wooden surfaces by using paint remover of approved brand in approved manner to prepare the surface smooth.
7Painting with synthetic enamel paint of approved brand and manufactureof required colour to give an even shade, one or more coats on old work.
8Finishing with Deluxe multi surface paint system for interiors andexteriors using primer as per manufacturers’ specifications: Painting steel work with deluxe multi surface paint of required shade to give an even shade. Two or more coats applied @ 0.90litre/10sqm over an under coat of primer applied @ 0.80litre/10sqm of approved brand and manufacture.
9Providing and fixing panelled or panelled and glazed shutters for doors,windows and clerestory windows fixing with butt hinges of required size withnecessary screws, excluding panelling which will be paid for separately, allcomplete as per direction of Engineer-in-charge. (Note: -Butt hinges andnecessary screws shall be paid separately). Second class kail wood 30mm.
10Providing and fixing of 19mm thick (water proof) marine ply of approved brand cabinets, shelves, Wardobe drawers, tables etc all shutters and edges of visible sides of 19mm ply shall be fixed with 15mm thick hard wood margin, all exposed faces inside as well out side have to finished with lamination (thickness 1mm minimum) of approved shade and make including all hardware fittings, channels, cover fillets, mouldings as per drawings. Century, Jeera, Premier, Duha or equivalent 300mm deep incl curtain rod.
11Repairing Existing CGI Sheet Roofing by applying Water Proofing Sealent/Putty/Silicone to Make the perforations leakproof Complete.
12Providing and fixing of MS welded wire mesh of size 25mmx25 mmx2.45mm (approx weight 2.70kg/sqm) in gables, side including necessary welding applying a steel primmer coat and two coats of steel paint, necessary scaffolding where ever required, but excluding of frame work which shall be paid seperately as per actual etc complete as per directions of Engineer in charge complete job.
13Engagement of Carpenters and Helpers for repairment.
14Skilled Carpenters.
15Helpers
16Helpers
17Providing and fixing of PVC panelling 10\\" wide 6mm thick of required shade and design of approved brand including all necessary secrews backing of 19mm thick Water proof-plyboard battens design approved by engineer incharge/consultants/client.complete job.
18Providing and fixing ISI marked aluminium fittings of approved brand and quality as per direction of Engineer-in-charge.
19Stainless Steel Butt Hinges 100x58x1.90 mm
20Stainless Steel Butt Hinges 75x47x1.80 mm
21Aluminum Tower bolts 150x10 mm
22Aluminum Tower bolts 100x10 mm
23Providing and fixing aluminum hanging floor door stopper, ISI marked,anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete .
24Single rubber stopper
25Cup Board Locks
26Providing and fixing aluminum handles ISI marked anodized (anodic coatingnot less than grade AC 10 as per IS: 1868) transparent or dyed to requiredcolour and shade with necessary screws etc. complete.
27125 mm size
28100 mm size
29Providing and fixing bright finished brass 100 mm mortice latch and lock with 6levers and a pair of lever handles of approved quality with necessary screws etc.complete.
30Aldrop with locking arrangement of Standard make/godrej(1.0\\" long) with all necessary fittings and fixtures as per the Direction of Engineer-In-charge
31Providing and fixing aluminum casement stays, ISI marked, anodized (anodiccoating not less than grade AC 10 as per IS : 1868) transparent or dyed torequired colour or shade with necessary screws etc. complete :
32Bright finished brass hard drawn hooks and eyes.100mm.
33Engagement of plumbers for dismental/re- fixing of water storage Tanks and repair of leakage to existing water supply system Excluding cost of material Etc complete job.
34Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as perI.S. 13983 with C.I. brackets and stainless steel plug 40 mm, includingpainting of fittings and brackets, cutting and making good the wallswherever required : Kitchen sink with drain board 510x1040mm bowl depth 250mm.
35Cleaning of floor by of stripping, scraping buffing and polishing, using Automatic Scruber floor cleaning Machine etc complete job.
36Providing and fixing panelled or panelled and glazed shutters for doors,windows and clerestory windows fixing with butt hinges of required size withnecessary screws, excluding panelling which will be paid for separately, allcomplete as per direction of Engineer-in-charge. (Note: -Butt hinges andnecessary screws shall be paid separately). Second class kail wood 35mm.
37Providing and fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with : 4.0mm thick glass panes.
38Providing and fixing plywood of 19mm thick at required levels incl framework, carriage and all hardware fiitings and fixtures complete as directed by Engineer in charge.
39Providing and fixing tiled False Ceiling of specified materials of size595x595mm in true horizontal level suspended on inter locking metal gridof hot dipped galvanized steel sections (galvanized @ 120 gms/sqm bothside inclusive ) consisting of main “T” runner with suitably spaced jointsto get required length and of size 24x38mm made from 0.30mm thick(minimum) sheet spaced at 1200 mm center to center and cross “T” of size24x25 mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200 x 600mm and secondary cross “T” of length 600mm and size 24x25 mm made of 0.30mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.30mm and laying false ceiling tiles of approved texture in the grid including, wherever, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size27x37x25x1.6mm fixed to ceiling with 12.5mm dia and 50mm long dashfasteners, 4mm GI adjustable rods with galvanized butterfly level clips ofsize 85x30x0.8 mm spaced at 1200mm center to center along size 85x30x0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. (The rate is excluding the cost of tiles which will be paid for separately). GI Metal Ceiling Lay in plain Tegular edge Global white colour tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending.
40Providing and fixing of Aluminum work for doors, windows, ventilators and partitions incl glazing with glass panes of 5mm thickness & 12mm thick decorative pre-laminated particle/MDF board(both side laminated) with extruded built up tubular sections/appropriate Z sections and other sections of approved make conforming to IS 733 and IS 1285, fixed with rawlplugs and screws incl necessary filling up of gaps at junctions, at tops, bottoms and sides with required PVC/neoprene felt etc.all complete as per directions of Engineer I/C for fixed portion, Electro coated aluminum complete as per approved drawings.
41Dismantling stone slab flooring laid in cement mortar including stackingof serviceable material and disposal of unserviceable material within 50meters lead.
42P/F of Sun Mica/ teak sheets to existing wardrobes/almirahs/ply incl cost of nails and other items involved complete.
43Dismantling of damaged cupboards including stacking of serviceable and disposal of unserviceable material beyound municipal limits complete job.
44Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In cement mortar.
45Dismantling tile work in floors and roofs laid in cement mortar includingstacking material within 50 meters lead. For thickness of tiles 10 mm to 25 mm.
46Dismantling (Mosaic (chip) tile work in floors and roofs laid in cement mortar including stacking material within 50 meters lead. For thickness of tiles above 25 mm and upto 40 mm.
47Demolishing cement concrete manually/by mechanical means includingdisposal of material within 50 meters lead as per direction of Engineer-incharge: 1:3:6 or richer mix (i/c equivalent design mix).
48Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) incl. all leads, lifts, head loads and carriages of all msterial involved complete.
49Providing and laying vitrified floor tiles in different sizes (thickness tobe specified by the manufacturer) with water absorption less than 0.08%and conforming to IS:15622 of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand)including grouting the joints with white cement and matching pigmentsetc. complete Size of tile 600x600 mm.
50Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in super structure above plinth level including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand).
51Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size).
52Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo-Mechanically Treated bars of grade Fe-500D or more.
53Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite of any colour or shade (Area of slab over 0.5 sqm).
54Providing double edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite Work.
55Providing & fixing underneath cabinets counters frame work of first class kail wood shutter of 19 mm thick ply board along with drawers mounted of steel channels with 0.80 mm dulmica of approved shade inclusive of all haerdware fittings like towerbolts, handles magnet catches inside shelves should be 19mmply board 600 m,m deep complete in all respects as designed and desired by engineer incharge.
56P/F and Making of Shelves of 45CM to 60 CM Deep with 19mm Block Board finishing with incl. all Fittings and Fixtures as directed bt EIC.
57Providing anf fixing wall hangings cabinets (600 mm high 400 mm deep) frame work of first class Badloo wood shutter of 19 mm thick ply board along with 0.80 mm dulmica of approved shade inclusive of all haerdware fittings like towerbolts, handles magnet catches inside shelves should be 19mmply board 400 mm deep complete in all respects as designed and desired by engineer incharge.
58Painting on G.S sheets with synthetic enamel paint of approved band andmanufacture of required colour to give an even shade on New work (twoor more coats) including a coat of approved steel primer but excluding acoat of mordant solution.
59Washrooms
60Dismantling tile work in floors and roofs laid in cement mortar includingstacking material within 50 meters lead. For thickness of tiles 10 mm to 25 mm.
61Dismantling old plaster or skirting, raking out joints and cleaning thesurface for plaster including disposal of rubbish to the dumping groundwithin 50 meters lead.
62Demolishing cement concrete manually/by mechanical means includingdisposal of material within 50 meters lead as per direction of Engineer-incharge: 1:3:6 or richer mix (i/c equivalent design mix).
63Removing dry or oil bound distemper, water proofing cement paint andthe like by scrapping and sand papering and preparing the surface smoothincluding necessary repairs to scratches etc. complete.
64Providing & Laying of stone soling (dully hand packed) including watering dressing and ramming incl. all-inclusive leads, lifts, loading, unloading, head load if any and carriage of materials from approved source to site of work complete.
65Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
66Supplying and applying bituminous solution primer on roof and or wall surface at 0.24 litre per sqm.
67Providing and laying water proofing treatment in sunken portion ofWCs, bathroom etc., by applying cement slurry mixed with waterproofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with waterproofing cement compound @ 0.253kg/ sqm. This layer will be allowedto air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with waterproofing cement compound @ 0.126 kg/sqm . This layer will be allowedto air cure for 4 hours followed with water curing for 48 hours The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
68Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
69Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand). incl. all leads, lifts, head loads and carriages of all material involved complete.
7015mm Cement plaster on the rough side of single or half brick wall ofmix: 1 : 4 ( 1 cement : 4 fine sand) incl. all leads, lifts, head loads and carriages of all material involved complete.
71Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622(thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm.
72Providing and laying vitrified floor tiles in different sizes (thickness tobe specified by the manufacturer) with water absorption less than 0.08%and conforming to IS:15622 of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) complete Size of tile 600x600 mm.
73Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of tile 1000x1000 mm.
74Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead : Of area of 3 sqm. and below.
75Providing and fixing of U-PVC casement/sliding/fix doors/windows in white colour, frame 60mm thick (min) x 45mm (min) with 1.5 mm GI reinforcement sash 39mm (min) 58mm (min) with 1.25mm GI U section reinforcement with rubber gasket of grey/black colour 10 years warranty against weathering of profile with complete hardware fittings fixed with 12mm thick laminated board panels as per design and with 5mm toughened glass and fiber jalli option if pre-febricated on german fabrication system( mosquito sash 18mm(min) x 43mm(min) (with welled cornes) complete at site including all fixtures.
76Painting with synthetic enamel paint of approved brand and manufactureto give an even shade. Two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand and manufacture.
77Clearance of septic tank by way of Engagement of suckers for clearing, taking out all the slush, unhygienic material from the tanks and disposal of the same beyond Municipal limits complete job.
78Providing and fixing water closet squatting pan (Indian type W.C. pan)with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C.flushing cistern, including flush pipe (of approved make) with manuallycontrolled device (handle lever) conforming to IS: 7231, with all fittingsand fixtures complete, including cutting and making good the walls andfloors wherever required. White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests.
79Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps.
80P/F CP 15 MM DIA WASH BASIN/SINK MIXER OF STANDARD DESIGN AND OF APPROVED QUALITY AND MAKE COMPLETE. SAMPLE TO BE APPROVED BY ENGINEER IN CHARGE.
81P/F CP ANGLE VALVES 15 MM DIA OF APPROVED BRAND WITH CP WALL FLANGE OF APPROVED QUALITY AND MAKE COMPLETE INCLUDING CUTTING AND MAKING GOOD WALLS.SAMPLE TO BE APPROVED BY ENGINEER IN CHARGE
82P/F OF CP FITTINGS OF APPROVED BRAND AND MANUFACTURE-TWO IN ONE BIB COCK.
83P/F stainless steel Anti cockroach type trap gratings
84P/F CP health faucet of approved brand with connections incl CP Wall flange etc
85P/F PVC connections of required size and of Standard quality
86P/F PVC waste pipe of required size and standard quality
87P/F of 600x20 MM Towel rails of approved quality incl. cost of screws and making good walls wherever necessary.
88P/F CP soap dish/Tray of approved make including cost of screws.
89P/F 600 x 450 MM bevelled edge mirror of approved quality with 6MM marine ply wood with CP brass screws and washers.
90Providing, installation, commissioning and testing 50 litre capacity Hot water Geyser of approved make including fixing with bolts and making necessary connections. Make: Venus, Racold or Hindware to be approved by the Engineer-in-Charge.
91Providing and fixing 3 layer PP-R (Poly propylene Random copolymer)pipes conforming to IS: 15801, UV stabilized and anti-microbial fusionwelded, having thermal stability for hot and cold water supply includingall PP-R plain and brass threaded Polypropylene random fittings. Thisincludes testing of joints complete as per direction of Engineer-incharge.
92Internal work Concealed fixing the pipe with clamps at1.00 meter spacing including cutting chases and making good thewall etc.
93PN-16 pipe , 25mm OD(SDR-7.4)
94External work including trenching, refilling etc.
95PN-16 pipe, 40mm OD (SDR-7.4)
96PN-16 pipe , 32mm OD (SDR-7.4)
97Providing and fixing PPR Unions.
98PPR Union 25mm
99PPR Union 32mm
100PPR Union 40mm
101Providing and Fixing PPR ball valve of approved quality, High or Low pressure, with plastic floats complete.
10240mm dia. Nominal bore
10332mm dia. Nominal bore
10425mm dia. Nominal bore
105Cutting holes up to 30x30 cm in walls including making good the same: With common burnt clay (non modular) bricks.
106Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passingdrain pipe etc. and repairing the hole after insertion of drain pipe etc.with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20 mm nominal size), including finishing complete so as tomake it leak proof.
107Provding and Fixing Sanitary PVC pipes (B-TYPES) of standard quality incl fittings, cutting and making good the walls & floors complete.
10850mm dia
10975mm dia
110100mm dia
111Floot Traps
112Reducer 100x75mm
113100mm door bend /TEE
114PVC Half Bend 45 degree 75mm.
115PVC Plain Tee 75mm
116Collers
11775mm door Bend.
118Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
119Providing and fixing PTMT liquid soap container 109 mm wide, 125 mmhigh and 112 mm distance from wall of standard shape with brackets ofthe same materials with snap fittings of approved quality and colour,weighing not less than 105 gms.
120Providing and fixing 600x120x5mm glass shelf with edges round offsupported on anodized aluminum angle frame with C.P. brass bracketsand guard rail complete fixed with 40 mm long screws, rawl plugs, etc.complete.
121Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominalsize), foundation concrete 1:4:8 mix (1 cement : 4 coarsesand (zone- III): 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mmthick with cement mortar 1:3 (1 cement : 3coarse sand) finished withfloating coat of neat cement and making channels in cement concrete1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mmnominal size) finished with a floatingcoat of neat cement complete as perstandard design : Inside size 90x80 cm and 45 cm deep including C.I. cover withframe (light duty) 455x610 mm internal dimensions, total weight ofcover and frame to be not less than 38 kg (weight of cover 23 kg andweight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5.
122Providing Retro-reflective regulatory sign board of required with and hight made out of 2mm thick aluminum sheet, face to be fully covered with highintensity encapsulated lens type retro-reflective sheeting as approved by Engineer-in-charge. Letter, symbols, borders, etc. will be as per IRC:67 with required colour scheme on the boards and with the high intensity grade A. the aluminum sheet to be riveted to M.S. frame of pipe size 75mmx4mm. The boards will be fixed to 1 No. 50x50mm square post made of M.S. pipe 75mmx4mm, welded to the frame with adequate anti-theft arrangement. Sheet work to be painted with two or more coats of synthetic enamel paint over an under coat (primer) and backside of aluminum sheet to be painted with two or more coats of epoxy paint including appropriate priming coat complete in all respects as perdirections of Engineer-in-charge. with 150 mmx6mm pipes at the sides for support and frame of 75x4mm pips as per requirement at site.
123Plumbing And Sanitary Installations
124PVC Septic Tanks
125Providing and fixing in position polyethylene septic tank type-B (Comfort or equivalent) having capacity for 20 users, 47\\"x51\\"x119\\" inches in size, including excavation of per as per the size, providing and laying of 150mm thick bed concrete in 1:4:8 mix (1: cement:4 course Sand :8 graded stone agg 20mm nominal size) filling the septic tank with fresh water, connecting the inlet and outlet with the septic tank and filling the dry course of sand and bajre around the septic tank complete Job including carriage of all materials involved.
126Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand).
127Centering and shuttering including strutting, propping etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platforms.
128Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size).
129Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
130P/F In Position Cast Iron Manhole Cover 600mmX600mm Incl Cost of Frame Work and and Hinges Complete.
131Making soak pit 2.5 m diameter 3.0 meter deep with 45x45 cm dry brickhoney comb shaft with common burnt clay (non modular) bricks of classdesignation 7.5 bricks and S.W. drain pipe 100 mm diameter, 1.8 m longcomplete as per standard design.
132Supplying and filling in plinth with fine sand under floors including, watering,ramming, consolidating and dressing complete.
133Electrical
134Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2x 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor (Polycab Green/Havell Life guard/ Fenolex/ Salzer/RR/Apar make as desired by engineer incharge) single core cable in surface / recessed medium class PVC conduit, (excluding the cost of conduit), complete, with modular switch Antibacterial series (Legrand/ABB/Siemens make.), modular plate, suitable Gi box and earthing the point with 1.5 sq.mmFRLS PVC insulated copper conductor single core cable etc. as required.
135Wiring for group controlled (looped) light point/fan point/exhaust fan point/call bell point (without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor (Polycab Green/Havell Life guard/Fenolex/ Salzer/RR/ Apar make as desired by engineer incharge) single core cable in surface/ recessed PVC conduit (excluding the cost of conduit), as required.
136Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 1/16 A modular switch, modular plate, suitable Gl box, connections etc. as required. Modular Switch & Socket Antibacterial series (Legrand/ABB/Siemens make.)
137Wiring for light/ power plug with 2X4 sq. mm + 1X 4 sq. mm earth wire FRLS/HFFR PVC insulated copper conductor (Polycab Green/Havell Life guard/Fenolex /Salzer/RR/Apar make as desired by engineer incharge )) single core cable in surface/recessed medium class PVC conduit.(( excluding the cost of conduit), complete
138Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 modular socket outlet and 5/6 A modular switch, Antibacterial series ( Legrand/ABB/Siemens make.)connections etc. as required.
139Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, Connections etc. as required. (For light plugs to be used in non residential buildings). Modular Switch & Socket:- Antibacterial series (Legrand / ABB / Siemens make).
140Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. Antibacterial series (Legrand / ABB / Siemens make).
141Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor (Polycab Green/Havell Life guard/ Fenolex/ Salzer, RR/Apar make as desired by engineer incharge), single core cable in surface/ recessed medium class PVC conduit as required. (excluding the cost of conduit), complete.
1422x1.5 sqmm + 1x1.5 sqmm earth wire
1432x2.5 sqmm +1x2.5 sqmm earth wire
1442x6 sqmm+1x6 sqmm earth wire
1454x10 sqmm+2x6 sqmm earth wire
1464x16 sqmm+2x6 sqmm earth wire
147Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required
148Supplying and fixing of following sizes of medium class PVC conduit( Anchor/ Ravindra/ Eq. make)along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required, with cement plaster, wall putty, paint, complete
14925mm.
15032mm.
151Supply and fixing of 25mm wide Medium Class PVC Casing & Capping (FRLS type) with necessary accessories such as saddles, couplers, tees, bends, and junction boxes, complete as per specifications.
152Supply and fixing of 100mm x 50mm wide Medium Class PVC Casing & Capping (FRLS type) with necessary accessories such as saddles, couplers, tees, bends, and Junction boxes, complete as per specifications.
153Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc as required (But without MCB/RCCB/Isolator). (legrand/Schinider/L&T /ABB/equivalent standard make as directed by engineer incharge.)
1546 way (4+18). Double Door
155Supply installation testing and commissioning of 15-18 W LED Surface/recess, Mounted light luminary fitting, square or round shape with minimum system lumen efficacy ≥ 120 lm/Watt with Pressure Die cast Aluminium Housing and Heat Sink and P.F.>0.95,THD<10%,CCT 5700K, CRI 80. The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision. The Input voltage range shall be 150V to 270V The Fixture should have In-built Surge Protection of 2kV. Certification: LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years,which includes replacement of fixtures of Philips/Helonix/Wipro / Regent make / sample to be approved before mstallation...
156S/F testing and comm. Of surface mounted LED Batten 20 watt-22 watt 1watt commercial series (cool/warm) 4 ft. with minimum system lumen efficacy of ≥ 120 Im/Watt with Pressure Die cast Aluminium Heat Sink and P.F>0.95, THD<10%, CCT 5700K, CRI 80. The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V The Fixture should have In-built Surge Protection of 2kV. Certification: LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India. Philips/ Helonix/Wipro make. sample to be approved before installation.
157S/F testing and comm. Of surface mounted LED Batten 36 watt-40 watt 1watt commercial series (cool/warm) 4 ft. with minimum system lumen efficacy of ≥ 120 lm/Watt with Pressure Die cast Aluminium Heat Sink and P.F.>0.95, THD<10%, CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V.The Fixture should have In-built Surge Protection of 2kV. Certification:-LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. Philips/ Helonix/Wipro make. sample to be approved before Installation.
158S/F testing and comm. Of MCB's 10 kA of the below mentioned capacities in sub main controls legrand C curve/ Schinider Acti 9/ L&T ABB make as directed by engineer incharge
1596-32 Amp SP MCB
16040-63 Amp DP MCB
16140-63 Amp TPN MCB
162Supply installation testing and comm. Of 200-250mm sweep exhaust fan Shutter type of havell /Bajaj/Crompton make as directed by engineer incharge, including making of space in wall/ window as per site requirement and necessary connections
163Supply installation testing and comm. Of Heavy Duty 300mm sweep exhaust fan Steel body of havell/Bajaj/Crompton make as directed by engineer Incharge, Including making of space in wall/ window as per site requirement and necessary connections
164Supply, Installation, Testing and Commissioning of 3-4 star, 1200 mm sweep, ceiling fan with 3 No. Aluminium blades, 30 cm long down rod, 2nos. canopies, shackle kit, Power Factor not less than 0.9, Service Value Including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, and including Iron hook complete. USHA/Havells /Crompton/orient make as directed by engineer Incharge.
165Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box Including connections but excluding modular plate etc. as required. Antibacterial serles (Legrand /ABR/Siemens make.)
166Supply fixing testing and comm. Of backlite holder/batten holder/angle holder/ceiling rose SSK/Anchor make Incl. PVC Block.
167Providing of Chemical earthing as per IS standards by way of digging 10' deep pit then embedding 3 meter G.I Earthing electrode, 80mm dia. connecting the plate with main control board by 10 SWG copper wire with 1/2\\" dia. Full thread brass nut and bolt and washers. Refilling of pit with chemical compound.
168Engaging of skilled labour for Dismentling of old damaged materials like wires in scraps, fixtures switches-sockets complete as directed by the engineer at site and stacking and handing over to concerned department including carrying out some repairing works etc.
169Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc, conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct In ground (75 cm below ground level) Including excavation and refilling the trench but excluding sand cushloning and protective covering etc. complete as required.
170160mm dia (OD-160mm & ID-135 mm nominal)
171Supply installation, test and Comm. Of invertor battery 150 AH/12 V Exide invatubular / eq. standard make as directed by engineer-in-charge.
172Supply Installation testing and commissioning of Sine Wave Inverter Capacity 3.5 KVA, Supports four battery, 24 Month Warranty Safe for sensitive appliances with Sine wave out-put, Inverter should run heavy loads like AC, Geyser, Photocopiers, Auto over-load handling capacity Installation and maintenance friendly Offers high quality and reliable power back-up solution for office and homes, MCB for protection from Input mains, Bypass switch for supplying output directly from grid in case of Home UPS fault. Noiseless Operations with the help of low harmonic distortion, Intuitive Display to easily understand status of mains availability, battery status, etc. Comprehensive protection against short-circuit, reverse polarity, battery over-charge, deep-discharge etc.Adaptive Battery charging control system technology (ABCC) ensures faster battery charging and enhances battery life by around 70%.Supports a wide battery range, i.e. Flat Plate, Tubular & VRLA (SMF).praffered make Luminous/ Microtek/Exide. the job also includes 2 No Trollies to house 4 No Battries.
173Supplying, Installation, Testing and Commissioning of CO2 Type Fire Extinguisher 4.5 Kg. Capacity ISI Mark (IS:15683) suitable for 'B' and 'C' class fires-inflammable liquids, gaseous fires like L.P.G. and acetylene, and electrical. Ceasefire/ equivalent make as desired by engineer incharge
174(Main Distribution panel) Supplying, Installation, Testing and Commissioning of Cubical Type Indoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers, Out Goings, Bus Bars etc. as required as per the Following Description. (IP:42)(Building Distribution Panel). The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating. The Panel Builder Shall be CPRI/ERDA/ANY NABL ACCREDITED LAB approved.with latest ammendment IS61439.Refer SLD.
175Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required.
176Normal incoming:-
177b)250 amp TPN MCCB 35 KA Including spreader links including spreader links, icu=ics=100% (Adjustable thermal and Adjustable magnetic release) Legrand/Shinider/Semlens/ABB make.
178b) 4 No. of Aluminium Bus Bar of 400 Amp.
179Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set etc.
180d) onload Change over switch 200 Amp for generator.Front operated.
181e) 4 No. of Aluminium Bus Bar of 300 Amp
182Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set etc.
183INVERTER INCOMING:-
184a) 100 amp DP MCCB 10 K Legrand/Shinider/ Eq. Standard make.
185b) 02 No. of Aluminium Bus Bar of 160 Amp.
186OUTGOING:-
187a) 100A 4P MCCB 25 KA including spreader links, (Adjustable thermal and Adjustable magnetic release) Legrand/Shinider/L&T/ABB/make.
188F.P 63A 10 Ka \\"C\\" Curve MCB Legrand/Shinider/Semiens/ABB make.
189D.P 63 A 10 Ka \\"C\\" Curve MCB Legrand/Shinider/Semiens/ABB make
190(c) space for 12 way MCB's
191S/L, testing and commissioning of PVC alluminium armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard make as directed by engineer incharge and making end termination with brass compression gland and aluminium lugs of required size.
192a)120 sq.mm 3.5 core
193a)35 sq.mm 4 core
194Supplying and installing following size or perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) Including bends, Tees, cross members and allied accessories with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
195200 mm width X 50 mm depth X 1.6 mm thickness Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57920906
AUTHORITY Government Departments
TENDER VALUE 1.25 Crore
LAST DATE 15-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for Upgradation, Renovation And Repair Of Girls Hostel At Govt. Polytechnic For Women Srinagar (Old Block).
Basic Detail
Tender No NIT No.67/EE/RnB/BM/CS/6816-24 of 2026-27 DATED 06.10.2026
Bidding Type Tender
Location
City Budgam
State Jammu and Kashmir
Key Dates
Publish Date 08 Oct 2026
Submission Date 15 Oct 2026
Open Date 16 Oct 2026
Finance
Tender Value 1.25 Crore
Tender Fee 2600
EMD 2.51 Lakhs
Exemption Not Available
Document List
BOQ_1107172.xls
fa739334-2e93-4db4-91c0-f30e51496ec0.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 08, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Today

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1107172.xls

html

fa739334-2e93-4db4-91c0-f30e51496ec0.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender