Tender for Upgradation, Renovation And Repair Of Girls Hostel At Govt. Polytechnic For Women Srinagar (Old Block).
BOQ
| Sl. No. | Item Description |
| 1 | Removing dry or oil bound distemper, water proofing cement paint andthe like by scrapping and sand papering and preparing the surface smoothincluding necessary repairs to scratches etc. complete. |
| 2 | Repairs to plaster of thickness 12mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape raking outjoints and preparing and plastering the surface of the walls completeincluding disposal of rubbish to the dumping ground within 50 meters lead With cement mortar 1:4 (1 cement : 4 fine sand). |
| 3 | Providing and applying white cement based putty of specified thickness,of approved brand and manufacturer, over the plastered wall surface toprepare the surface even and smooth complete. 2 mm thick |
| 4 | Distempering with 1st quality acrylic distemper (ready mixed)havingVOC content less than 50 gms/litre,two or more coats on new work ofapproved manufacturer, of required shade and colour complete as permanufacturer’s specifications Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface. |
| 5 | Finishing walls with acrylic smooth exterior paint of required shade onNew work (Two or more coats applied @ 1.67 liter/10sqm over andincluding priming coat of exterior primer applied @ 2.20kg/10sqm). |
| 6 | Removing old paint from metallic / wooden surfaces by using paint remover of approved brand in approved manner to prepare the surface smooth. |
| 7 | Painting with synthetic enamel paint of approved brand and manufactureof required colour to give an even shade, one or more coats on old work. |
| 8 | Finishing with Deluxe multi surface paint system for interiors andexteriors using primer as per manufacturers’ specifications: Painting steel work with deluxe multi surface paint of required shade to give an even shade. Two or more coats applied @ 0.90litre/10sqm over an under coat of primer applied @ 0.80litre/10sqm of approved brand and manufacture. |
| 9 | Providing and fixing panelled or panelled and glazed shutters for doors,windows and clerestory windows fixing with butt hinges of required size withnecessary screws, excluding panelling which will be paid for separately, allcomplete as per direction of Engineer-in-charge. (Note: -Butt hinges andnecessary screws shall be paid separately). Second class kail wood 30mm. |
| 10 | Providing and fixing of 19mm thick (water proof) marine ply of approved brand cabinets, shelves, Wardobe drawers, tables etc all shutters and edges of visible sides of 19mm ply shall be fixed with 15mm thick hard wood margin, all exposed faces inside as well out side have to finished with lamination (thickness 1mm minimum) of approved shade and make including all hardware fittings, channels, cover fillets, mouldings as per drawings. Century, Jeera, Premier, Duha or equivalent 300mm deep incl curtain rod. |
| 11 | Repairing Existing CGI Sheet Roofing by applying Water Proofing Sealent/Putty/Silicone to Make the perforations leakproof Complete. |
| 12 | Providing and fixing of MS welded wire mesh of size 25mmx25 mmx2.45mm (approx weight 2.70kg/sqm) in gables, side including necessary welding applying a steel primmer coat and two coats of steel paint, necessary scaffolding where ever required, but excluding of frame work which shall be paid seperately as per actual etc complete as per directions of Engineer in charge complete job. |
| 13 | Engagement of Carpenters and Helpers for repairment. |
| 14 | Skilled Carpenters. |
| 15 | Helpers |
| 16 | Helpers |
| 17 | Providing and fixing of PVC panelling 10\\" wide 6mm thick of required shade and design of approved brand including all necessary secrews backing of 19mm thick Water proof-plyboard battens design approved by engineer incharge/consultants/client.complete job. |
| 18 | Providing and fixing ISI marked aluminium fittings of approved brand and quality as per direction of Engineer-in-charge. |
| 19 | Stainless Steel Butt Hinges 100x58x1.90 mm |
| 20 | Stainless Steel Butt Hinges 75x47x1.80 mm |
| 21 | Aluminum Tower bolts 150x10 mm |
| 22 | Aluminum Tower bolts 100x10 mm |
| 23 | Providing and fixing aluminum hanging floor door stopper, ISI marked,anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete . |
| 24 | Single rubber stopper |
| 25 | Cup Board Locks |
| 26 | Providing and fixing aluminum handles ISI marked anodized (anodic coatingnot less than grade AC 10 as per IS: 1868) transparent or dyed to requiredcolour and shade with necessary screws etc. complete. |
| 27 | 125 mm size |
| 28 | 100 mm size |
| 29 | Providing and fixing bright finished brass 100 mm mortice latch and lock with 6levers and a pair of lever handles of approved quality with necessary screws etc.complete. |
| 30 | Aldrop with locking arrangement of Standard make/godrej(1.0\\" long) with all necessary fittings and fixtures as per the Direction of Engineer-In-charge |
| 31 | Providing and fixing aluminum casement stays, ISI marked, anodized (anodiccoating not less than grade AC 10 as per IS : 1868) transparent or dyed torequired colour or shade with necessary screws etc. complete : |
| 32 | Bright finished brass hard drawn hooks and eyes.100mm. |
| 33 | Engagement of plumbers for dismental/re- fixing of water storage Tanks and repair of leakage to existing water supply system Excluding cost of material Etc complete job. |
| 34 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as perI.S. 13983 with C.I. brackets and stainless steel plug 40 mm, includingpainting of fittings and brackets, cutting and making good the wallswherever required : Kitchen sink with drain board 510x1040mm bowl depth 250mm. |
| 35 | Cleaning of floor by of stripping, scraping buffing and polishing, using Automatic Scruber floor cleaning Machine etc complete job. |
| 36 | Providing and fixing panelled or panelled and glazed shutters for doors,windows and clerestory windows fixing with butt hinges of required size withnecessary screws, excluding panelling which will be paid for separately, allcomplete as per direction of Engineer-in-charge. (Note: -Butt hinges andnecessary screws shall be paid separately). Second class kail wood 35mm. |
| 37 | Providing and fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with : 4.0mm thick glass panes. |
| 38 | Providing and fixing plywood of 19mm thick at required levels incl framework, carriage and all hardware fiitings and fixtures complete as directed by Engineer in charge. |
| 39 | Providing and fixing tiled False Ceiling of specified materials of size595x595mm in true horizontal level suspended on inter locking metal gridof hot dipped galvanized steel sections (galvanized @ 120 gms/sqm bothside inclusive ) consisting of main “T” runner with suitably spaced jointsto get required length and of size 24x38mm made from 0.30mm thick(minimum) sheet spaced at 1200 mm center to center and cross “T” of size24x25 mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200 x 600mm and secondary cross “T” of length 600mm and size 24x25 mm made of 0.30mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.30mm and laying false ceiling tiles of approved texture in the grid including, wherever, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size27x37x25x1.6mm fixed to ceiling with 12.5mm dia and 50mm long dashfasteners, 4mm GI adjustable rods with galvanized butterfly level clips ofsize 85x30x0.8 mm spaced at 1200mm center to center along size 85x30x0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. (The rate is excluding the cost of tiles which will be paid for separately). GI Metal Ceiling Lay in plain Tegular edge Global white colour tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. |
| 40 | Providing and fixing of Aluminum work for doors, windows, ventilators and partitions incl glazing with glass panes of 5mm thickness & 12mm thick decorative pre-laminated particle/MDF board(both side laminated) with extruded built up tubular sections/appropriate Z sections and other sections of approved make conforming to IS 733 and IS 1285, fixed with rawlplugs and screws incl necessary filling up of gaps at junctions, at tops, bottoms and sides with required PVC/neoprene felt etc.all complete as per directions of Engineer I/C for fixed portion, Electro coated aluminum complete as per approved drawings. |
| 41 | Dismantling stone slab flooring laid in cement mortar including stackingof serviceable material and disposal of unserviceable material within 50meters lead. |
| 42 | P/F of Sun Mica/ teak sheets to existing wardrobes/almirahs/ply incl cost of nails and other items involved complete. |
| 43 | Dismantling of damaged cupboards including stacking of serviceable and disposal of unserviceable material beyound municipal limits complete job. |
| 44 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In cement mortar. |
| 45 | Dismantling tile work in floors and roofs laid in cement mortar includingstacking material within 50 meters lead. For thickness of tiles 10 mm to 25 mm. |
| 46 | Dismantling (Mosaic (chip) tile work in floors and roofs laid in cement mortar including stacking material within 50 meters lead. For thickness of tiles above 25 mm and upto 40 mm. |
| 47 | Demolishing cement concrete manually/by mechanical means includingdisposal of material within 50 meters lead as per direction of Engineer-incharge: 1:3:6 or richer mix (i/c equivalent design mix). |
| 48 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) incl. all leads, lifts, head loads and carriages of all msterial involved complete. |
| 49 | Providing and laying vitrified floor tiles in different sizes (thickness tobe specified by the manufacturer) with water absorption less than 0.08%and conforming to IS:15622 of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand)including grouting the joints with white cement and matching pigmentsetc. complete Size of tile 600x600 mm. |
| 50 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in super structure above plinth level including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand). |
| 51 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 52 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo-Mechanically Treated bars of grade Fe-500D or more. |
| 53 | Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite of any colour or shade (Area of slab over 0.5 sqm). |
| 54 | Providing double edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite Work. |
| 55 | Providing & fixing underneath cabinets counters frame work of first class kail wood shutter of 19 mm thick ply board along with drawers mounted of steel channels with 0.80 mm dulmica of approved shade inclusive of all haerdware fittings like towerbolts, handles magnet catches inside shelves should be 19mmply board 600 m,m deep complete in all respects as designed and desired by engineer incharge. |
| 56 | P/F and Making of Shelves of 45CM to 60 CM Deep with 19mm Block Board finishing with incl. all Fittings and Fixtures as directed bt EIC. |
| 57 | Providing anf fixing wall hangings cabinets (600 mm high 400 mm deep) frame work of first class Badloo wood shutter of 19 mm thick ply board along with 0.80 mm dulmica of approved shade inclusive of all haerdware fittings like towerbolts, handles magnet catches inside shelves should be 19mmply board 400 mm deep complete in all respects as designed and desired by engineer incharge. |
| 58 | Painting on G.S sheets with synthetic enamel paint of approved band andmanufacture of required colour to give an even shade on New work (twoor more coats) including a coat of approved steel primer but excluding acoat of mordant solution. |
| 59 | Washrooms |
| 60 | Dismantling tile work in floors and roofs laid in cement mortar includingstacking material within 50 meters lead. For thickness of tiles 10 mm to 25 mm. |
| 61 | Dismantling old plaster or skirting, raking out joints and cleaning thesurface for plaster including disposal of rubbish to the dumping groundwithin 50 meters lead. |
| 62 | Demolishing cement concrete manually/by mechanical means includingdisposal of material within 50 meters lead as per direction of Engineer-incharge: 1:3:6 or richer mix (i/c equivalent design mix). |
| 63 | Removing dry or oil bound distemper, water proofing cement paint andthe like by scrapping and sand papering and preparing the surface smoothincluding necessary repairs to scratches etc. complete. |
| 64 | Providing & Laying of stone soling (dully hand packed) including watering dressing and ramming incl. all-inclusive leads, lifts, loading, unloading, head load if any and carriage of materials from approved source to site of work complete. |
| 65 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 66 | Supplying and applying bituminous solution primer on roof and or wall surface at 0.24 litre per sqm. |
| 67 | Providing and laying water proofing treatment in sunken portion ofWCs, bathroom etc., by applying cement slurry mixed with waterproofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with waterproofing cement compound @ 0.253kg/ sqm. This layer will be allowedto air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with waterproofing cement compound @ 0.126 kg/sqm . This layer will be allowedto air cure for 4 hours followed with water curing for 48 hours The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 68 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). |
| 69 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand). incl. all leads, lifts, head loads and carriages of all material involved complete. |
| 70 | 15mm Cement plaster on the rough side of single or half brick wall ofmix: 1 : 4 ( 1 cement : 4 fine sand) incl. all leads, lifts, head loads and carriages of all material involved complete. |
| 71 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622(thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm. |
| 72 | Providing and laying vitrified floor tiles in different sizes (thickness tobe specified by the manufacturer) with water absorption less than 0.08%and conforming to IS:15622 of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) complete Size of tile 600x600 mm. |
| 73 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of tile 1000x1000 mm. |
| 74 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead : Of area of 3 sqm. and below. |
| 75 | Providing and fixing of U-PVC casement/sliding/fix doors/windows in white colour, frame 60mm thick (min) x 45mm (min) with 1.5 mm GI reinforcement sash 39mm (min) 58mm (min) with 1.25mm GI U section reinforcement with rubber gasket of grey/black colour 10 years warranty against weathering of profile with complete hardware fittings fixed with 12mm thick laminated board panels as per design and with 5mm toughened glass and fiber jalli option if pre-febricated on german fabrication system( mosquito sash 18mm(min) x 43mm(min) (with welled cornes) complete at site including all fixtures. |
| 76 | Painting with synthetic enamel paint of approved brand and manufactureto give an even shade. Two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand and manufacture. |
| 77 | Clearance of septic tank by way of Engagement of suckers for clearing, taking out all the slush, unhygienic material from the tanks and disposal of the same beyond Municipal limits complete job. |
| 78 | Providing and fixing water closet squatting pan (Indian type W.C. pan)with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C.flushing cistern, including flush pipe (of approved make) with manuallycontrolled device (handle lever) conforming to IS: 7231, with all fittingsand fixtures complete, including cutting and making good the walls andfloors wherever required. White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 79 | Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. |
| 80 | P/F CP 15 MM DIA WASH BASIN/SINK MIXER OF STANDARD DESIGN AND OF APPROVED QUALITY AND MAKE COMPLETE. SAMPLE TO BE APPROVED BY ENGINEER IN CHARGE. |
| 81 | P/F CP ANGLE VALVES 15 MM DIA OF APPROVED BRAND WITH CP WALL FLANGE OF APPROVED QUALITY AND MAKE COMPLETE INCLUDING CUTTING AND MAKING GOOD WALLS.SAMPLE TO BE APPROVED BY ENGINEER IN CHARGE |
| 82 | P/F OF CP FITTINGS OF APPROVED BRAND AND MANUFACTURE-TWO IN ONE BIB COCK. |
| 83 | P/F stainless steel Anti cockroach type trap gratings |
| 84 | P/F CP health faucet of approved brand with connections incl CP Wall flange etc |
| 85 | P/F PVC connections of required size and of Standard quality |
| 86 | P/F PVC waste pipe of required size and standard quality |
| 87 | P/F of 600x20 MM Towel rails of approved quality incl. cost of screws and making good walls wherever necessary. |
| 88 | P/F CP soap dish/Tray of approved make including cost of screws. |
| 89 | P/F 600 x 450 MM bevelled edge mirror of approved quality with 6MM marine ply wood with CP brass screws and washers. |
| 90 | Providing, installation, commissioning and testing 50 litre capacity Hot water Geyser of approved make including fixing with bolts and making necessary connections. Make: Venus, Racold or Hindware to be approved by the Engineer-in-Charge. |
| 91 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer)pipes conforming to IS: 15801, UV stabilized and anti-microbial fusionwelded, having thermal stability for hot and cold water supply includingall PP-R plain and brass threaded Polypropylene random fittings. Thisincludes testing of joints complete as per direction of Engineer-incharge. |
| 92 | Internal work Concealed fixing the pipe with clamps at1.00 meter spacing including cutting chases and making good thewall etc. |
| 93 | PN-16 pipe , 25mm OD(SDR-7.4) |
| 94 | External work including trenching, refilling etc. |
| 95 | PN-16 pipe, 40mm OD (SDR-7.4) |
| 96 | PN-16 pipe , 32mm OD (SDR-7.4) |
| 97 | Providing and fixing PPR Unions. |
| 98 | PPR Union 25mm |
| 99 | PPR Union 32mm |
| 100 | PPR Union 40mm |
| 101 | Providing and Fixing PPR ball valve of approved quality, High or Low pressure, with plastic floats complete. |
| 102 | 40mm dia. Nominal bore |
| 103 | 32mm dia. Nominal bore |
| 104 | 25mm dia. Nominal bore |
| 105 | Cutting holes up to 30x30 cm in walls including making good the same: With common burnt clay (non modular) bricks. |
| 106 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passingdrain pipe etc. and repairing the hole after insertion of drain pipe etc.with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20 mm nominal size), including finishing complete so as tomake it leak proof. |
| 107 | Provding and Fixing Sanitary PVC pipes (B-TYPES) of standard quality incl fittings, cutting and making good the walls & floors complete. |
| 108 | 50mm dia |
| 109 | 75mm dia |
| 110 | 100mm dia |
| 111 | Floot Traps |
| 112 | Reducer 100x75mm |
| 113 | 100mm door bend /TEE |
| 114 | PVC Half Bend 45 degree 75mm. |
| 115 | PVC Plain Tee 75mm |
| 116 | Collers |
| 117 | 75mm door Bend. |
| 118 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 119 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mmhigh and 112 mm distance from wall of standard shape with brackets ofthe same materials with snap fittings of approved quality and colour,weighing not less than 105 gms. |
| 120 | Providing and fixing 600x120x5mm glass shelf with edges round offsupported on anodized aluminum angle frame with C.P. brass bracketsand guard rail complete fixed with 40 mm long screws, rawl plugs, etc.complete. |
| 121 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominalsize), foundation concrete 1:4:8 mix (1 cement : 4 coarsesand (zone- III): 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mmthick with cement mortar 1:3 (1 cement : 3coarse sand) finished withfloating coat of neat cement and making channels in cement concrete1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mmnominal size) finished with a floatingcoat of neat cement complete as perstandard design : Inside size 90x80 cm and 45 cm deep including C.I. cover withframe (light duty) 455x610 mm internal dimensions, total weight ofcover and frame to be not less than 38 kg (weight of cover 23 kg andweight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5. |
| 122 | Providing Retro-reflective regulatory sign board of required with and hight made out of 2mm thick aluminum sheet, face to be fully covered with highintensity encapsulated lens type retro-reflective sheeting as approved by Engineer-in-charge. Letter, symbols, borders, etc. will be as per IRC:67 with required colour scheme on the boards and with the high intensity grade A. the aluminum sheet to be riveted to M.S. frame of pipe size 75mmx4mm. The boards will be fixed to 1 No. 50x50mm square post made of M.S. pipe 75mmx4mm, welded to the frame with adequate anti-theft arrangement. Sheet work to be painted with two or more coats of synthetic enamel paint over an under coat (primer) and backside of aluminum sheet to be painted with two or more coats of epoxy paint including appropriate priming coat complete in all respects as perdirections of Engineer-in-charge. with 150 mmx6mm pipes at the sides for support and frame of 75x4mm pips as per requirement at site. |
| 123 | Plumbing And Sanitary Installations |
| 124 | PVC Septic Tanks |
| 125 | Providing and fixing in position polyethylene septic tank type-B (Comfort or equivalent) having capacity for 20 users, 47\\"x51\\"x119\\" inches in size, including excavation of per as per the size, providing and laying of 150mm thick bed concrete in 1:4:8 mix (1: cement:4 course Sand :8 graded stone agg 20mm nominal size) filling the septic tank with fresh water, connecting the inlet and outlet with the septic tank and filling the dry course of sand and bajre around the septic tank complete Job including carriage of all materials involved. |
| 126 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand). |
| 127 | Centering and shuttering including strutting, propping etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platforms. |
| 128 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 129 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 130 | P/F In Position Cast Iron Manhole Cover 600mmX600mm Incl Cost of Frame Work and and Hinges Complete. |
| 131 | Making soak pit 2.5 m diameter 3.0 meter deep with 45x45 cm dry brickhoney comb shaft with common burnt clay (non modular) bricks of classdesignation 7.5 bricks and S.W. drain pipe 100 mm diameter, 1.8 m longcomplete as per standard design. |
| 132 | Supplying and filling in plinth with fine sand under floors including, watering,ramming, consolidating and dressing complete. |
| 133 | Electrical |
| 134 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2x 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor (Polycab Green/Havell Life guard/ Fenolex/ Salzer/RR/Apar make as desired by engineer incharge) single core cable in surface / recessed medium class PVC conduit, (excluding the cost of conduit), complete, with modular switch Antibacterial series (Legrand/ABB/Siemens make.), modular plate, suitable Gi box and earthing the point with 1.5 sq.mmFRLS PVC insulated copper conductor single core cable etc. as required. |
| 135 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/call bell point (without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor (Polycab Green/Havell Life guard/Fenolex/ Salzer/RR/ Apar make as desired by engineer incharge) single core cable in surface/ recessed PVC conduit (excluding the cost of conduit), as required. |
| 136 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 1/16 A modular switch, modular plate, suitable Gl box, connections etc. as required. Modular Switch & Socket Antibacterial series (Legrand/ABB/Siemens make.) |
| 137 | Wiring for light/ power plug with 2X4 sq. mm + 1X 4 sq. mm earth wire FRLS/HFFR PVC insulated copper conductor (Polycab Green/Havell Life guard/Fenolex /Salzer/RR/Apar make as desired by engineer incharge )) single core cable in surface/recessed medium class PVC conduit.(( excluding the cost of conduit), complete |
| 138 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 modular socket outlet and 5/6 A modular switch, Antibacterial series ( Legrand/ABB/Siemens make.)connections etc. as required. |
| 139 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, Connections etc. as required. (For light plugs to be used in non residential buildings). Modular Switch & Socket:- Antibacterial series (Legrand / ABB / Siemens make). |
| 140 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. Antibacterial series (Legrand / ABB / Siemens make). |
| 141 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor (Polycab Green/Havell Life guard/ Fenolex/ Salzer, RR/Apar make as desired by engineer incharge), single core cable in surface/ recessed medium class PVC conduit as required. (excluding the cost of conduit), complete. |
| 142 | 2x1.5 sqmm + 1x1.5 sqmm earth wire |
| 143 | 2x2.5 sqmm +1x2.5 sqmm earth wire |
| 144 | 2x6 sqmm+1x6 sqmm earth wire |
| 145 | 4x10 sqmm+2x6 sqmm earth wire |
| 146 | 4x16 sqmm+2x6 sqmm earth wire |
| 147 | Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required |
| 148 | Supplying and fixing of following sizes of medium class PVC conduit( Anchor/ Ravindra/ Eq. make)along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required, with cement plaster, wall putty, paint, complete |
| 149 | 25mm. |
| 150 | 32mm. |
| 151 | Supply and fixing of 25mm wide Medium Class PVC Casing & Capping (FRLS type) with necessary accessories such as saddles, couplers, tees, bends, and junction boxes, complete as per specifications. |
| 152 | Supply and fixing of 100mm x 50mm wide Medium Class PVC Casing & Capping (FRLS type) with necessary accessories such as saddles, couplers, tees, bends, and Junction boxes, complete as per specifications. |
| 153 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc as required (But without MCB/RCCB/Isolator). (legrand/Schinider/L&T /ABB/equivalent standard make as directed by engineer incharge.) |
| 154 | 6 way (4+18). Double Door |
| 155 | Supply installation testing and commissioning of 15-18 W LED Surface/recess, Mounted light luminary fitting, square or round shape with minimum system lumen efficacy ≥ 120 lm/Watt with Pressure Die cast Aluminium Housing and Heat Sink and P.F.>0.95,THD<10%,CCT 5700K, CRI 80. The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision. The Input voltage range shall be 150V to 270V The Fixture should have In-built Surge Protection of 2kV. Certification: LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years,which includes replacement of fixtures of Philips/Helonix/Wipro / Regent make / sample to be approved before mstallation... |
| 156 | S/F testing and comm. Of surface mounted LED Batten 20 watt-22 watt 1watt commercial series (cool/warm) 4 ft. with minimum system lumen efficacy of ≥ 120 Im/Watt with Pressure Die cast Aluminium Heat Sink and P.F>0.95, THD<10%, CCT 5700K, CRI 80. The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V The Fixture should have In-built Surge Protection of 2kV. Certification: LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India. Philips/ Helonix/Wipro make. sample to be approved before installation. |
| 157 | S/F testing and comm. Of surface mounted LED Batten 36 watt-40 watt 1watt commercial series (cool/warm) 4 ft. with minimum system lumen efficacy of ≥ 120 lm/Watt with Pressure Die cast Aluminium Heat Sink and P.F.>0.95, THD<10%, CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V.The Fixture should have In-built Surge Protection of 2kV. Certification:-LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. Philips/ Helonix/Wipro make. sample to be approved before Installation. |
| 158 | S/F testing and comm. Of MCB's 10 kA of the below mentioned capacities in sub main controls legrand C curve/ Schinider Acti 9/ L&T ABB make as directed by engineer incharge |
| 159 | 6-32 Amp SP MCB |
| 160 | 40-63 Amp DP MCB |
| 161 | 40-63 Amp TPN MCB |
| 162 | Supply installation testing and comm. Of 200-250mm sweep exhaust fan Shutter type of havell /Bajaj/Crompton make as directed by engineer incharge, including making of space in wall/ window as per site requirement and necessary connections |
| 163 | Supply installation testing and comm. Of Heavy Duty 300mm sweep exhaust fan Steel body of havell/Bajaj/Crompton make as directed by engineer Incharge, Including making of space in wall/ window as per site requirement and necessary connections |
| 164 | Supply, Installation, Testing and Commissioning of 3-4 star, 1200 mm sweep, ceiling fan with 3 No. Aluminium blades, 30 cm long down rod, 2nos. canopies, shackle kit, Power Factor not less than 0.9, Service Value Including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, and including Iron hook complete. USHA/Havells /Crompton/orient make as directed by engineer Incharge. |
| 165 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box Including connections but excluding modular plate etc. as required. Antibacterial serles (Legrand /ABR/Siemens make.) |
| 166 | Supply fixing testing and comm. Of backlite holder/batten holder/angle holder/ceiling rose SSK/Anchor make Incl. PVC Block. |
| 167 | Providing of Chemical earthing as per IS standards by way of digging 10' deep pit then embedding 3 meter G.I Earthing electrode, 80mm dia. connecting the plate with main control board by 10 SWG copper wire with 1/2\\" dia. Full thread brass nut and bolt and washers. Refilling of pit with chemical compound. |
| 168 | Engaging of skilled labour for Dismentling of old damaged materials like wires in scraps, fixtures switches-sockets complete as directed by the engineer at site and stacking and handing over to concerned department including carrying out some repairing works etc. |
| 169 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc, conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct In ground (75 cm below ground level) Including excavation and refilling the trench but excluding sand cushloning and protective covering etc. complete as required. |
| 170 | 160mm dia (OD-160mm & ID-135 mm nominal) |
| 171 | Supply installation, test and Comm. Of invertor battery 150 AH/12 V Exide invatubular / eq. standard make as directed by engineer-in-charge. |
| 172 | Supply Installation testing and commissioning of Sine Wave Inverter Capacity 3.5 KVA, Supports four battery, 24 Month Warranty Safe for sensitive appliances with Sine wave out-put, Inverter should run heavy loads like AC, Geyser, Photocopiers, Auto over-load handling capacity Installation and maintenance friendly Offers high quality and reliable power back-up solution for office and homes, MCB for protection from Input mains, Bypass switch for supplying output directly from grid in case of Home UPS fault. Noiseless Operations with the help of low harmonic distortion, Intuitive Display to easily understand status of mains availability, battery status, etc. Comprehensive protection against short-circuit, reverse polarity, battery over-charge, deep-discharge etc.Adaptive Battery charging control system technology (ABCC) ensures faster battery charging and enhances battery life by around 70%.Supports a wide battery range, i.e. Flat Plate, Tubular & VRLA (SMF).praffered make Luminous/ Microtek/Exide. the job also includes 2 No Trollies to house 4 No Battries. |
| 173 | Supplying, Installation, Testing and Commissioning of CO2 Type Fire Extinguisher 4.5 Kg. Capacity ISI Mark (IS:15683) suitable for 'B' and 'C' class fires-inflammable liquids, gaseous fires like L.P.G. and acetylene, and electrical. Ceasefire/ equivalent make as desired by engineer incharge |
| 174 | (Main Distribution panel) Supplying, Installation, Testing and Commissioning of Cubical Type Indoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers, Out Goings, Bus Bars etc. as required as per the Following Description. (IP:42)(Building Distribution Panel). The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating. The Panel Builder Shall be CPRI/ERDA/ANY NABL ACCREDITED LAB approved.with latest ammendment IS61439.Refer SLD. |
| 175 | Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required. |
| 176 | Normal incoming:- |
| 177 | b)250 amp TPN MCCB 35 KA Including spreader links including spreader links, icu=ics=100% (Adjustable thermal and Adjustable magnetic release) Legrand/Shinider/Semlens/ABB make. |
| 178 | b) 4 No. of Aluminium Bus Bar of 400 Amp. |
| 179 | Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set etc. |
| 180 | d) onload Change over switch 200 Amp for generator.Front operated. |
| 181 | e) 4 No. of Aluminium Bus Bar of 300 Amp |
| 182 | Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set etc. |
| 183 | INVERTER INCOMING:- |
| 184 | a) 100 amp DP MCCB 10 K Legrand/Shinider/ Eq. Standard make. |
| 185 | b) 02 No. of Aluminium Bus Bar of 160 Amp. |
| 186 | OUTGOING:- |
| 187 | a) 100A 4P MCCB 25 KA including spreader links, (Adjustable thermal and Adjustable magnetic release) Legrand/Shinider/L&T/ABB/make. |
| 188 | F.P 63A 10 Ka \\"C\\" Curve MCB Legrand/Shinider/Semiens/ABB make. |
| 189 | D.P 63 A 10 Ka \\"C\\" Curve MCB Legrand/Shinider/Semiens/ABB make |
| 190 | (c) space for 12 way MCB's |
| 191 | S/L, testing and commissioning of PVC alluminium armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard make as directed by engineer incharge and making end termination with brass compression gland and aluminium lugs of required size. |
| 192 | a)120 sq.mm 3.5 core |
| 193 | a)35 sq.mm 4 core |
| 194 | Supplying and installing following size or perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) Including bends, Tees, cross members and allied accessories with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 195 | 200 mm width X 50 mm depth X 1.6 mm thickness Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 08, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 15, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedOct 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
TodayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender