Bids Are invited for Boq For Smoke Detector
Tender Overview
Project Description
Bids Are invited for Boq For Smoke Detector Supply Installation, Testing And Commissioning Of Microprocessor Based Standalone Fire Alarm Control Panel. , Supply Installation, Testing And Commissioning Of Addressable Smoke Detector With Inbuilt Optical Smoke Sensors As Per Nfpa Style 7 Wiring Complete With Base And Termination As Required , Supply Installation, Testing And Commissioning Of Addressable Manual Call Point As Per Nfpa Style 7 Wiring Complete As Required With Backbox , Supply, Installation, Testing And Commissioning Of Sounder Strobe , Supply, Installation, Testing And Commissioning Of Addressable Single Output Module, Suitable To Drive Conventional Notification Devices Or Other Power Required Equipment , Supply, Installation, Testing And Commissioning Of Loop Isolator Module, Protection Facility For Addressable Loop , Supply, Installation, Testing And Commissioning Of 2C X 1.5 Sq Mm Frls Armored Cable - Supply Installation, Testing And Commissioning Of Microprocessor Based Standalone Fire Alarm Control Panel. - Supply Installation, Testing And Commissioning Of Microprocessor Based Standalone Fire Alarm Control Panel. Each Loop Capable Of Taking Minimum 1 9 8 Detector And Devices, 6 X40 Character (2 40 X 64 Pixels Blue Graphical Liquid Crystal Display (Lcd) With Backlight Illumination & Alpha-Numeric Keypad To Offer Clear Menu Navigation And Quick Configuration. The Penal Shall Be Addressable Type. The Panel Shall Be Able Give Pin Point Location Of All Fire / Fault Conditions. The Panel Must Be Able To Automatically Switch Off Respective Control Switches Whenever Any Alarm Is Triggered. The Penal Shall Have In Built Rectifier, Loop Cards Lcd Unit To Indicate Fire /Fault Signal With Address Internal Event Log Capacity Of 500 To 999 Non- Volatile Events Complete In All Respects With Battery Backup Dxc1-M , Supply Installation, Testing And Commissioning Of Addressable Smoke Detector With Inbuilt Optical Smoke Sensors As Per Nfpa Style 7 Wiring Complete With Base And Termination As Required - Supply Installation, Testing And Commissioning Of Addressable Smoke Detector With Inbuilt Optical Smoke Sensors As Per Nfpa Style 7 Wiring Complete With Base And Termination As Required (Hm-Pseap + Mi/B501ap/Iv) , Supply Installation, Testing And Commissioning Of Addressable Manual Call Point As Per Nfpa Style 7 Wiring Complete As Required With Backbox - Supply Installation, Testing And Commissioning Of Addressable Manual Call Point As Per Nfpa Style 7 Wiring Complete As Required With Backbox (Hm-Mcp-Gi+Bb) , Supply, Installation, Testing And Commissioning Of Sounder Strobe - Supply, Installation, Testing And Commissioning Of Sounder Strobe (9 7 Db(A) + Or - 3 Db At Sign 1 Meter 2) (Wss-Prno5 + Mi/B5 0 1 Ap/Iv) , Supply, Installation, Testing And Commissioning Of Addressable Single Output Module, Suitable To Drive Conventional Notification Devices Or Other Power Required Equipment - Supply, Installation, Testing And Commissioning Of Addressable Single Output Module, Suitable To Drive Conventional Notification Devices Or Other Power-Required Equipment In 4-Wire Mode By External 24Vdc Power Supply And Also Capable To Provide Dry Contact Output In Loop-Powered Mode. Maximum 1 A Output Current. This Shall Include All Accessories Like Additional Power Supply, Relays Etc. Complete As Required For Services Integration (Mi /Dcmoe). , Supply, Installation, Testing And Commissioning Of Loop Isolator Module, Protection Facility For Addressable Loop - Supply, Installation, Testing And Commissioning Of Loop Isolator Module, Protection Facility For Addressable Loop, Can Isolate Shorted Circuit From Complete Loop To Ensure Normal Operation Of Other Parts (Mi/Diso). , Supply, Installation, Testing And Commissioning Of 2C X 1.5 Sq Mm Frls Armored Cable
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Supply Installation, Testing and Commissioning of Microprocessor based Standalone fire alarm control panel. | Supply Installation, Testing and Commissioning of Microprocessor based Standalone fire alarm control panel. Each loop capable of taking minimum 1 9 8 detector and devices, 6 x40 character (2 40 x 64 Pixels blue graphical liquid crystal display (LCD) with backlight illumination & alpha-numeric keypad to offer clear menu navigation and quick configuration. The penal shall be addressable type. The panel shall be able give pin point location of all fire / fault conditions. The panel must be able to automatically switch off respective control switches whenever any alarm is triggered. The penal shall have in built rectifier, loop cards LCD unit to indicate fire /fault signal with address internal event log capacity of 500 to 999 non- volatile events complete in all respects with battery backup DXc1-M |
| 2 | Supply Installation, Testing and Commissioning of Addressable Smoke Detector with inbuilt optical smoke sensors as per NFPA style 7 wiring complete with base and termination as required | Supply Installation, Testing and Commissioning of Addressable Smoke Detector with inbuilt optical smoke sensors as per NFPA style 7 wiring complete with base and termination as required (HM-PSEAP + MI/B501AP/IV) |
| 3 | Supply Installation, Testing and Commissioning of Addressable Manual Call Point as per NFPA style 7 wiring complete as required with backbox | Supply Installation, Testing and Commissioning of Addressable Manual Call Point as per NFPA style 7 wiring complete as required with backbox (HM-MCP-GI+BB) |
| 4 | Supply, Installation, Testing and Commissioning of Sounder Strobe | Supply, Installation, Testing and Commissioning of Sounder Strobe (9 7 dB(A) + or - 3 dB At sign 1 meter 2) (WSS-PRNO5 + MI/B5 0 1 AP/IV) |
| 5 | Supply, Installation, Testing and Commissioning of Addressable Single Output Module, suitable to drive conventional notification devices or other power required equipment | Supply, Installation, Testing and Commissioning of Addressable Single Output Module, suitable to drive conventional notification devices or other power-required equipment in 4-wire mode by external 24VDC power supply and also capable to provide dry contact output in loop-powered mode. Maximum 1 A output current. This Shall Include all accessories like additional power supply, relays etc. complete as required for services integration (MI /DCMOE). |
| 6 | Supply, Installation, Testing and Commissioning of Loop Isolator Module, protection facility for addressable loop | Supply, Installation, Testing and Commissioning of Loop Isolator Module, protection facility for addressable loop, can isolate shorted circuit from complete loop to ensure normal operation of other parts (MI/DISO). |
| 7 | Supply, Installation, Testing and Commissioning of 2C x 1.5 sq mm FRLS Armored Cable | Supply, Installation, Testing and Commissioning of 2C x 1.5 sq mm FRLS Armored Cable |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender