Tender For Repair, Maintenance & Constrction Of Road Guillies And Other Allied Works In Capital Complex Sector-1, U.T Chandigarh.(Ch. To:-2215 Non Plan)
Tender Value
3.57 Lakhs
Estimated cost
Bid Submission
14 Oct 2026
5 days left
EMD
7158
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair, Maintenance & Constrction Of Road Guillies And Other Allied Works In Capital Complex Sector-1, U.T Chandigarh.(Ch. To:-2215 Non Plan)
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. .2.8 |
| 2 | All kinds of soil. .2.8.1 |
| 3 | Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : .2.10 |
| 4 | All kinds of soil .2.10.1 |
| 5 | Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia .2.10.1.2 |
| 6 | Providing & laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work up to plinth level : .4.1 |
| 7 | 1:2:4 (1cement :2coarse sand :4graded stone aggregate 20mm nominal size) .4.1.3 |
| 8 | 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) .4.1.10 |
| 9 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). .5.3 |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for :. .5.9 |
| 11 | Suspended floors, roofs, landings, balconies and access platform .5.9.3 |
| 12 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.. .5.22 |
| 13 | Thermo-Mechanically Treated bars of grade Fe-500D or more. .5.22.6 |
| 14 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: .6.1 |
| 15 | Cement mortar 1:4 (1 cement : 4 coarse sand) .6.1.1 |
| 16 | 12 mm cement plaster finished with a floating coat of neat cement of mix : .13.7 |
| 17 | 1:4 (1 cement: 4 fine sand) .13.7.2 |
| 18 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - incharge. .15.3 |
| 19 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. .16.83 |
| 20 | Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost). .16.84 |
| 21 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : .19.1 |
| 22 | 150 mm diameter .19.1.2 |
| 23 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : .19.3 |
| 24 | 150 mm diameter S.W. pipe .19.3.2 |
| 25 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : .19.6 |
| 26 | 300 mm dia. R.C.C. pipe .19.6.4 |
| 27 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality .19.19 |
| 28 | H D - 20 .19.19.3 |
| 29 | Circular shape 560 mm internal diameter .19.19.3.1 |
| 30 | Providing and Fixing of precast RCC Road Gully cover and frame (27\\"x22\\"0 complete in all respect. .NSR |
| 31 | Providing and Fixing of SFRC inspection camber cover 600x600x35 mm thick made out of M.S. angle iron size 35x35x5 mm and TMT bars 10 mm i/d both sides includig cutting weilding and fixing with Cement concrete 1:1/2:3. .NSR |
| 32 | Providing and Fixing of SFRC G.T. cove 375x375x25 mm thick made out of M.S. angle iron size 25x25x5 mm thick with fixingwire mash 1\\"x1\\" of 10 gauge including cutting weilding and fixing with Cement conrete 1:1 1/2:3. .NSR |
| 33 | Providing the services of JCB excavator for locating the buried line, excavation, backfilling etc. complete in all respect. .NSR |
| 34 | Providing and Fixing of repair camps of various kinds of pipes leakag made of SS 304, EPDM rubber nuts & bolts Complete in all respects make VAG/ L&T/ Kirloskar/ VC of following sizes for repairing the leakage of all kind of pipes. NSR |
| 35 | 100 mm dia length 300 mm . |
| 36 | Providing and Fixing of repair clamps for PVC pipe leakage Tertiary water line complete in all respects. NSR |
| 37 | 90mm o/d UPVC Pipe . |
| 38 | 110mm o/d UPVC Pipe . |
| 39 | Providing and Fixing PVC pipe of 6 kg/Cm2 complete in all respect. .NSR |
| 40 | 110mm PVC Pipe . Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysOct 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender