Tender For Repair / Replacement Of Gi/Ms Pipe Lines Of Various Sizes, Sluice Valve, Valve Pits And Other Misc Work For Spring Area At Dagshai Under Ge Kasauli
Tender Value
35 Lakhs
Estimated cost
Bid Submission
22 Oct 2026
9 days left
EMD
70000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Solan → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair / Replacement Of Gi/Ms Pipe Lines Of Various Sizes, Sluice Valve, Valve Pits And Other Misc Work For Spring Area At Dagshai Under Ge Kasauli
BOQ
| Sl. No. | Item Description |
| 1 | SCHDULE 'A' |
| 2 | Excavation in trenches in hard dense soil n.exc 1.5 mtr wide & n.exc 1.5mtr in depth and n. exc. 10sqm on plan for laying pipe in trenches and getting out complete all as specified and directed. |
| 3 | Returning filling in trenches, spreading, levelling, watering and well ramming in layers n.exc 25cm in hard dense soil complete all as specified and directed. |
| 4 | Removing of surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above starting point complete all as specified and directed. |
| 5 | Dismantling and taking out old u/s worn out MS/CI/GI pipe line flanged type 150 mm bore including fittings complete with nuts, bolts, washers and gaskets etc and removing from the site complete all as specified and as directed by Engineer-in-charge. Note:- New pipes shall be laid first at spring area and old ones to be taken out later. |
| 6 | Supplying, laying, jointing and testing hot finished seamless carbon steel pipe not less than YST-240, grade B as per ASTM A 106, Sch 40, nominal size NPS-150 mm, outer dia 164.22 mm, with nominal wall thickness 7.11 mm and weight 28.26 Kg/ mtr, including short pieces as required at site, laid in trenches/over RCC pillars/across or under bridges/along hill side (up or down)/culverts/inside valve pits complete all as specified and directed by Engr-in-charge. NOTE:- (i) Excavation Earth work, PCC, seamless pipe fittings, MS flanges & flanged joints shall be measured and paid for separately under relevant items. (ii) Work will be carried out in piecemeal locations experienced based on break downs and weaker sections of existing rising main as per site requirement and as directed by Engineer-in-charge. (iii) Any other expenses for obtaining permision from state authorities for road cutting job are included under this item. |
| 7 | M&L for MS Flange of ASA-150 standard suitable for 150mm dia bore seamless pipe comprising of inner dia 170.70 mm, outer dia 279.4 mm and thickness 25.40 mm, flange having 8 holes drilled to accomodate bolts of size not less than 22.2mm dia, PCS 241.3 complete for jointing with the existing pipes, duly welded with pipes/fittings bends properly to both the plain ends complete all as specified. and directed. |
| 8 | Supply and fixing of joint for 150 mm nominal bore pipes, comprising one 5.0 mm thick steel-reinforced compressed asbestos fibre gasket, including 8 Nos M38 nuts and bolts (each bolt not less than 25 mm in diameter and 125 mm in length), and 2 Nos. 5 mm thick washers per joint, suitable for pipes/fittings/bends, complete all as specified and directed by the Engineer-in-Charge. |
| 9 | Dismantling and taking out old u/s worn out MS/CI/GI pipe line flanged type 100 mm bore including fittings complete with nuts, bolts, washers and gaskets etc and removing from the site complete all as specified and as directed by Engineer-in-charge. Note:- New pipes shall be laid first at spring area and old ones to be taken out later. |
| 10 | Supplying, laying, jointing and testing hot finished seamless carbon steel pipe not less than YST-240, grade B as per ASTM A 106, Sch 40, nominal size NPS-100 mm, outer dia 114.30 mm, with nominal wall thickness 6.02 mm and weight 16.08 Kg/ mtr, including short pieces as required at site, laid in trenches/over RCC pillars/across or under bridges/along hill side (up or down)/culverts/inside valve pits complete all as specified and directed by Engr-in-charge. NOTE:- (i) Excavation Earth work, PCC, seamless pipe fittings, MS flanges & flanged joints shall be measured and paid for separatly under relevant items. (ii) Work will be carried out in piecemeal locations experienced based on break downs and weaker sections of existing rising main as per site requirement and as directed by Engineer-in-charge. (iii) Any other expenses for obtaining permision from state authorities for road cutting jobs are included under this item. |
| 11 | S&F, MS flange of ASA-100 standard suitable for 100 mm bore seamless pipes, comprising of size internal dia 116.10 mm, outer dia 228.6 mm and 23.80 mm thick flange having 8 holes drilled to accomodate bolts of size not less than 19.00mm dia, PCS 190.5 complete for jointing with the existing pipes, duly welded with pipes/fittings bends properly to both the plain ends complete all as specified and directed. |
| 12 | Supply and fixing of joint for 100 mm nominal bore pipes, comprising one 5.0 mm thick steel-reinforced compressed asbestos fibre gasket, including 8 Nos M38 nuts and bolts (each bolt not less than 25 mm in diameter and 125 mm in length), and 2 Nos. 5 mm thick washers per joint, suitable for pipes/fittings/bends, complete all as specified and directed by the Engineer-in-Charge. |
| 13 | S & F in replacement of Air release valve of size 150mm, DI Single Chamber, Tripple Action with SS floating And working parts & Fb Epoxy coating in PN1.6 confoming to IS 14845 incl 8 Nos holes,19.05mm dia ,100mm long Nut ,bolts, 2 nos washer incl 3 mm thick gasket suitable for pipeline of required size and shape complete for jointing with the existing pipes, duly welded with pipes/fittings bends properly to both the plain ends complete all as specified. and directed. |
| 14 | S & F in replacement of Air release valve of size 100mm -ditto- here-in-after all as per Ser item No.12 above complete all as specified and directed. |
| 15 | S & F in replacement of Air release valve of size 80mm -ditto- here-in-after all as per Ser item No.12 above complete all as specified and directed. |
| 16 | Supplying, laying, jointing and testing in replacement Tees of 150mm dia, of suitable length and as per site requirement, made of hot finished seamless carbon steel pipe not less than YST-240, grade B as per ASTM A 106, Sch 40, nominal size NPS-150 mm, outer dia 164.22 mm, with nominal wall thickness 7.1 mm and weight 28.2 Kg/ Rm, including short pieces with flanged ends duly fabricated as required at site, laid in trenches/over RCC pillars/across or under bridges/along hill side (up or down)/culverts/inside valve pits complete all as specified and directed by Engr-in-charge. |
| 17 | Supplying, laying, jointing and testing in replacement Tees of 100mm dia, of suitable length and as per site requirement, made of hot finished seamless carbon steel pipe not less than YST-240, grade B as per ASTM A 106, Sch 40, nominal size NPS-100 mm, outer dia 112.04 mm, with nominal wall thickness 6.02 mm and weight 16.08 Kg/ mtr, including short pieces with flanged ends duly fabricated as required at site, laid in trenches/over RCC pillars/across or under bridges/along hill side (up or down)/culverts/inside valve pits complete all as specified and directed by Engr-in-charge. |
| 18 | Supplying, laying, jointing and testing in replacement, Bends of 150mm dia -ditto- here-in-after all as per ser item No.15 above complete all as specified and directed by Engr-in-charge. |
| 19 | Supplying, laying, jointing and testing in replacement, Bends of 100mm dia -ditto- here-in-after all as per ser item No.16 above complete all as specified and directed by Engr-in-charge. |
| 20 | Supplying, fixing in replacement and testing of High Pressure Sluice Valve of Size DN 150, Pressure Rating: ASME Class 300, API 600- Design standard, shall be hydrostatically tested in accordance with API 598, Pressure-Temperature Rating ASME B16.34, Stainless Steel ASTM A182 F6a / SS410, rising stem, Handwheel-operated, Body and Bonnet Material: ASTM A216 Grade WCB Cast Carbon Steel, both ends flanged, after removal of old unserviceable valve without damaging to existing pipe line complete all as specified and directed by Engr-in-charge. NOTE:- Suitable size MS Flange for existing pipe line, joints and joining materials shall be included under this item itself. |
| 21 | Supplying, fixing in replacement and testing of High Pressure Non-Return Valve (Swing Check Valve), ASME Class 300, Pressure Rating ASME Class 300, API 6D / BS 1868 - Design Standard shall be hydrostatically tested in accordance with API 598, Body Material of ASTM A216 Grade WCB Cast Carbon Steel both ends flanged, after removal of old unserviceable NRV without damaging to existing pipe line complete all as specified and diected by Engr-in-charge. NOTE:- Suitable size MS Flange for existing pipe line, joints and joining materials shall be included under this item itself. |
| 22 | M & L for Cutting down leaking piece of pipe 150 mm. Cut down the rusted & leaking portion , providing (i) new piece of MS Pipe of 150 mm upto 0.50 metre long. (ii) New union socket 150 mm - 1 Nos. (iii) Jointing the new pipe with existing old pipe by means of welding to make it leakproof including testing on completion complete all as specified and directed.Note:- Unit rate quoted shall be included for (a) Necessary excavation/earth work (b) New MS pipe 150 mm upto 0.50 metre length (c) union & socket 150mm - 1 Nos each. (d) welding etc complete including testing on complete. |
| 23 | M & L for Cutting down leaking piece of pipe 100 mm. Cut down the rusted & leaking portion , providing (i) new piece of MS Pipe of 100 mm upto 0.50 metre long (ii) New union socket 100 mm - 1 Nos. (iii) Jointing the new pipe with existing old pipe by means of welding to make it leakproof including testing on completion complete all as specified and directed.Note:- Unit rate quoted shall be included for (a) Necessary excavation/earth work (b) New MS pipe 100 mm upto 0.50 metre length (c) union & socket 150mm - 1 Nos each. (d) welding etc complete including testing on complete. |
| 24 | S & F in replacement of sluice Valve PN1.6 Epoxy coated with ssp & HW size 150mmincl 8 Nos 19.05mm dia ,100mm long Nut ,bolts, 2 nos washer incl 3 mm thick gasket of required size and shape complete for jointing with the existing pipes, duly welded with pipes/fittings bends properly to both the plain ends complete all as specified. and directed. |
| 25 | S & F in replacement of sulice valve PN1.6 Epoxy coated with ssp & HW size 100mm incl 8 Nos 19.05mm dia ,100mm long Nut ,bolts, 2 nos washer incl 3 mm thick gasket of required size and shape complete for jointing with the existing pipes, duly welded with pipes/fittings bends properly to both the plain ends complete all as specified. and directed. |
| 26 | S & F in replacement of sulice valve PN1.6 Epoxy coated with ssp & HW size 80mm incl 8 Nos 19.05mm dia ,100mm long Nut ,bolts, 2 nos washer incl 3 mm thick gasket of required size and shape complete for jointing with the existing pipes, duly welded with pipes/fittings bends properly to both the plain ends complete all as specified. and directed. |
| 27 | Construction of brick masonary pit of size 160x120x120 Cm internal size with MS Sheet 3MM Thick and angle iron frame of size 40x40x6mm duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer including locking arrangement with lock with 3 keys, lifting handle and includng excavation / earth work, PCC in foundation, brick work , plaster including demolaton of existing pit complete all as specified and directed by Engr- in-Charge. |
| 28 | Construction of brick masonary pit of size 120x90x90 Cm internal size with MS Sheet 3MM Thick and angle iron frame of size 40x40x6mm duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer including locking arrangement with lock with 3 keys, lifting handle and includng excavation / earth work, PCC in foundation, brick work , plaster including demoliton of existing pit complete all as specified and directed by Engr- in-Charge. |
| 29 | M & L for PCC (1:3:6) type C2 using 40mm graded stone aggregate for anchorage blocks for pipe line/making good the cut portion of roads/paths/hard standings etc including necessary from work where required , to support the pipe line complete all as specified and as directed by Engineer-in-charge. |
| 30 | M & L for Removing water meter for testing, etc., by unscrewing unions, fitting unions with screw plugs, or inserting short length or tubing screwed both ends so as to maintain supply and Replacing meter (old or new), taking out plugs or temporary connections and reconnecting meter and unions for pipes of dia 15mm bore complete all as specified and directed . |
| 31 | Ditto - all as per ser item No. 29 above here-in-before but for pipes of dia 20mm bore complete all as specified and directed . |
| 32 | Ditto - all as per ser item No. 29 above here-in-before but for pipes of dia 40mm bore complete all as specified and directed . |
| 33 | Ditto - all as per ser item No. 29 above here-in-before but for pipes of dia 50mm bore complete all as specified and directed . |
| 34 | M & L for Replacing meter with flanged joints, including removal of flanged connecting piece, or blank flange (if required) or taking out meter for testing, etc., and fixing (but not supplying) a length of flanged connecting pipe (or two blank flanges) and labour only for two flanged joints for MS pipes of dia 150mm dia bore complete all as specified and directed. |
| 35 | Ditto - all as per ser item No. 33 above here-in-before but for MS pipes of dia 100mm bore complete all as specified and directed . |
| 36 | Ditto - all as per ser item No. 33 above here-in-before but for MS pipes of dia 80mm bore complete all as specified and directed . (Note for ser item Nos 29 to 35 : New Water meters for replacing the unsv meters shall be issued by MES. Old unsv meters retreived shall be deposited to MES store for disposal action) Please Enable Macros to View BoQ information |
| 37 | Ditto - all as per ser item No. 33 above here-in-before but for MS pipes of dia 80mm bore complete all as specified and directed . (Note for ser item Nos 29 to 35 : New Water meters for replacing the unsv meters shall be issued by MES. Old unsv meters retreived shall be deposited to MES store for disposal action) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 08, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 22, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysOct 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender