Tender For Repair/ Maintenance Of Day To Day Complaints Of Perimeter Street Lights, Area Lights, High Mast Lights, Solar Lights And Certain E/M Works At Af Stn Sulur.
Tender Overview
Project Description
Tender for Repair/ Maintenance Of Day To Day Complaints Of Perimeter Street Lights, Area Lights, High Mast Lights, Solar Lights And Certain E/M Works At Af Stn Sulur.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 29-Oct-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 05-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GARRISON ENGINEER (AF) SULUR NAME OF WORK : REPAIR/ MAINT OF DAY TO DAY COMPLAINTS OF PERIMETER STREET LIGHTS, AREA LIGHTS, HIGH MAST LIGHTS, SOLAR LIGHTS AND CERTAIN E/M WORKS AT AF STN SULUR. CA NO: GE(AF)/SUL/ OF 2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Item of Work Item Code / Make Quantity Unit Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT (in Words) |
| 2 | Disconnecting & taking out unserviceable one and S&F LED aviation obstruction light with IP 66 protection water clear poly carbonate UV stabilized dome neoprene rubber with bird spike with 302 Nos LED bulbs including necessary electric connections including 2.5 sqmm, 2 core, PVC copper cables fixed on wall with 20mm dia PVC conduit from DB to light fitting fixed in and including GI pipe 25mm dia 1 mtr long grouted with PCC complete/ binding with existing angle frame etc complete all as specified and directed. |
| 3 | Attending non functional street light complaints (for street light / perimeter lights / high mast light / flood light etc of any type / size fitted on poles / walls / post / pillars etc.,) by deploying technically qualified and experinced techinicians to find out defective / taking out unserviceable parts such as electronic driver, pvc insulated copper conductor cable for connecting street light fittings etc and repairing by changing the defective parts including minor repair to cable connection / loose connection, screws, nuts & bolts and insulation tape to insulate the LT joint etc and testing at AF Station Sulur (both domestic & technical area) complete all as specified and as directed. |
| 4 | Notes for item No. 2:- The rates quoted shall be deemed to be inclusive of the following:-(a) The above job shall be carried out by a trained electrician having ITI qualification in electrical; documentary proof of the education of tradesman shall be produced before commencement of work to the Engr-in-charge.(b) Contractor or his authorised representitive has to inspect all street / security lights on Daily basis at their own arrangement between 7.00 PM to 9.00 PM and maintain the record in Register which shall be put up to Engineer-in-Charge / JE on the very next day.(c) A Joint Inspection for serviceability of all Street / Security Lights shall be carried out from 7.00 PM to 9.00 PM on every friday by Engineer-in-Charge / JE (E/M) / user along with contractor or his authorised representative.(d) Contractor has to arrange own moveable Generator of suitable capacity for repairing and testing of the street / security lights, defect rectification of Cables, etc. and to check the serviceability after repair. No Electricity shall be provided by the department on this account.(e) Quoted unit rate shall deemed to be inclusive of attending any breakdown of Street/ Security Lights during night. Contractor has to arrange electrician and helper and all necessary T&P and equipments to remove the breakdown. Fault shall be intimated through telephone / SMS.(f) In case of any delay in attending the complaint more than 12 hrs after handing over routine/urgent work, the contractor shall be liable to pay the penalty as described in penalty clause given here as under. |
| 5 | (g) The penalty shall be applicable to the contractor if the delay is noticed by the Engr-in-Charge more than twelve hrs after handing over works of urgent nature to the contractor. The Engr-in-Charge shall handover the slip containing specification of work to the contractor by lodging the time and signature of contractor be obtained on slip. The contractor shall attend the complaint immediately and shall report to Engr-in-Charge with in 12 hrs. The contractor shall keep his tradesmen in stand by for attending any routine / urgent works from the executive. If the nature of job is such that the work cannot be completed within period of 12hrs then the facts shall be brought to the notice of the GE/Engr-in-Charge and the period for the working to the complaint shall be decided by the GE/EIC. If the delay is more than twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 50/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other than the condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforceable as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Dept. The decision of the Accepting Officer is this regards shall be final and binding.(h) Contractor has to ensure serviceability of all Street/ Security Lights of DOMESTIC & TECHNICAL AREA on Daily basis in any Weather Condition at their own arrangement.(j) Contractor shall provide conveyance to the deployed labour for maintaining the services without any extra cost to department. (k) Vehicle mounted ladder for maintaining services shall be provided by the contractor at no extra cost to department. (l) Materials required for the repairing of the lights shall be measured and paid separately under respective items. But labour required for taking down, dismantling, repairing and replacing parts and reinstalling and testing the street lights fittings shall be deemed to include in the rate quoted. |
| 6 | (m) Necessary T&P, Safety Belt, Vehicle, Aluminium Ladder, etc. will be arranged by the Contractor and Cost for the same shall deem to be included in the quoted Unit Rate.(n) All safety measures and provn of all safety devices, first aid box etc shall be provided by the contractor. Contractor will be solely responsible for full safety of the persons deployed for providing the services and department will have no liability for any type of accident/injury of any type. Unit rate quoted shall be deemed to include the cost of the same and no extra payment shall be made on this part.(o) All type of T & P, PVC insulation tapes, minor nuts/ bolts/ washers etc required for maintaining the services shall be provided by the contractor without any extra cost to department.(p) Attending and repairing complaint for one light of any type shall be measured and paid as one Job.(q) Earth work (if necessary at Site) for removing of any Cable Fault shall be measured and Paid under respective Items.(r) The contractor shall maintain a record of all urgent work at and if the work is repeated due to poor workmanship, he shall be liable to repair the same without any extra expenditure to the Govt.(s) Contractor shall provide contact details of his responsible persons for any emergency.(t) Any Materials replaced which are not specified in SCHEDULE OF CREDIT shall be deposited to MES STORE YARD without any extra Cost to the Department. |
| 7 | S&F in replacement with new electronic driver with input voltage 220 to 240 Volt and output voltage suitable for LED light fitting of capacity 10 to 25 watt complete all as specified and directed. |
| 8 | S&F in replacement with new electronic driver with input voltage 220 to 240 Volt and output voltage suitable for LED light fitting of capacity 30 to 45 watt complete all as specified and directed. |
| 9 | S&F in replacement new electronic driver with input voltage 220 to 240 Volt and output voltage suitable for LED light fitting of capacity 60 to 90 watt complete all as specified and as directed. |
| 10 | S&F in replacement with new electronic driver with input voltage 220 to 240 Volt and output voltage suitable for LED light fitting of capacity 100 to 110 watt complete all as specified and directed. |
| 11 | S&F in replacement with new electronic driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 120 to 140 watt complete all as specified and directed. |
| 12 | S&F in replacement with new electronic driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 140 to 160 watt complete all as specified and as directed. |
| 13 | S&F in replacement with new electronic driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 180 to 210 watt complete all as specified and directed. |
| 14 | M&L for disconnecting of burnt / damaged cables from panels / junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tapes etc and reconnecting using new nuts / bolts / washer etc and restoring three phase and neutral in the junction box complete all as directed for the 25 / 35 sqmm 3.5 core size of LT underground armoured cables complete all as specified and directed.Note:- Earth work required for extending the incoming/ outgoing cable in junction box / panel board etc shall be deemed to be included in the rate quoted. |
| 15 | Disconnecting & taking out unserviceable one and S&F GI tubing 40 mm bore light grade 1.2 m long bent to shape as required with clamps for fixing of street light on poles/ walls including nuts, bolts, washers clamps of suitable size complete all as specified and directed. |
| 16 | Disconnecting & taking out unserviceable one and S&F Single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 complete all as specified and directed. |
| 17 | Disconnecting & taking out unserviceable one and S&F LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 18 | Disconnecting & taking out unserviceable one and S&F TPN MCB 40 to 100 amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 complete all as specified and directed. |
| 19 | Excavation in trenches in soft / loose soil not exceeding 1.5m wide and not exceeding 1.5 metre in depth for laying of cable and not exceeding 10 Sqm on plan for poles, struts, stays etc. and not exceeding 1.5 m in depth and getting out complete all as specified and directed |
| 20 | M&L for Riddling earth obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming complete all as per specified and as directed. Notes:- In case sufficient earth not obtained from excavation, the rate shall be deemed to be inclusive for additional qty of earth required to be obtained from out side MoD land as directed. |
| 21 | Removing excavated materials not exceeding 50m distance and depositing where directed at level not exceeding 1.5 m above the starting point complete all as per specified and as directed. |
| 22 | S&F Fly ash bricks using modular bricks as in cable protection cover including taking down existing bricks of any size complete all as per specified and as directed. |
| 23 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soil all as specified and as directed. |
| 24 | S&F XLPE insulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100 Volts grade cross sectional area 25 Sqmm 3.5 core laid in trenches / ducts / fixed to wall / pole / inside panel / drawn through pipe including cable glands and terminal sockets including taking down existing cable etc complete all as specified and directed. Note for item No 23.00: Excavation and earth work shall be measured and paid under Item No 18.00 |
| 25 | Disconnecting & taking out unserviceable one and S&F Cable jointing kit for 1.1 KV grade cable for outdoor straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armored aluminium conductor cable of size 10 sqmm to 16 sqmm complete all as specified and directed. |
| 26 | M&L for cutting existing PCC road / bitumen road / drain for laying of DI / GI or any type of pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, wide 800mm including making good existing surface with PCC 1:2:4 type B1 using 20mm aggregate thickness of concrete is 150mm complete all as specified and directed. |
| 27 | Notes for item No 25.00:- The tenderer shall take into consideration for following points while quoting his rate for this item and the unite rate shall be deemed to include for :-(i) Earth work excavation in any type of soil(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed.(iii) Removing excavated material to out side MoD land(iv) Laying of any type / any bore of pipe in trenches including taking down any description. Supply of pipe shall be measured and paid separately.(v) 150 mm thick PCC 1:2:4 type B1 as in any type of road (vi) GI pipe required for cable protection shall be measured and paid separately under respective item. But labour required for take the cable through GI pipe and laying in trench shall deemed to be included in the rate quoted. |
| 28 | Disconnecting & taking out unserviceable one and S&F GI pipe 50 mm bore light grade for cable protection complete all as specified and as diercted. |
| 29 | M&L for preparing the existing painted steel surface and painting with one coat of aluminium paint on cross arms, clamps, MS flat and street light brackets if any on steel / RCC pole for double cross arm for three phase 4 wire system complete all as specified and as diercted. |
| 30 | Disconnecting & taking out unserviceable one and S&F LED flood light 210 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 31 | S&F XLPE insulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 16 Sqmm 4 core laid in trenches / ducts / fixed to wall / pole / inside panel / drawn through pipe including cable glands and terminal sockets including taking down existing cable etc all as specified and directed. Note: Excavation and earth work shall be measured and paid seperately. |
| 32 | Disconnecting & taking out unserviceable one and Supply, installation and erection of steel tubular swaged poles of 9 mtr long type 410, SP- 31, IS-2713 marked complete with CI / MS base plate 6 mm thick of sixe 300 x 300 mm, final taper plug, bolts, nuts, washers and screws as specified, drilling of necessary holes including painting with two coats of aluminium paint over a coat of red oxide primer on exposed surface and black bituminous paint on steel surface embeded in concrete externally and throughout internally and painting 03 nos of band / strips with fluorescent, PO box red synthetic enamel paint (30 cm wide each) at a distance of 30 cm from plinth block and writing pole number complete all as specified & directed.Note :- Earth work excavation, PCC foundation, coping shall be measured and paid separately. The rate for pole shall also be included painting to steel tubular pole. |
| 33 | M&L for Plain cement concrete 1:4:8, type D2 (using 40mm graded stone aggregate ) including necessary form work for foundation of poles and stay assembly for bed concrete complete all as specified and directed. |
| 34 | M&L for Plain cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) including necessary form work for foundation of poles and stay assembly for bed concrete complete all as specified and directed. |
| 35 | M&L for plain cement concrete 1:2:4 type B1(using 20mm graded crushed stone aggregate) as in benching,coping including weathering slightly rounded or chamfered angles or as per site requirement with necessary plastering work complete all as specified and directed. |
| 36 | Disconnecting & taking out unserviceable one and S&F Power contactors 63 Amps, 4 pole, 415V complete all as specified and as directed. |
| 37 | M&L for preparation of the painted steel surfaces of existing LT / steel tubular pole including cross arms, clamps MS flats, steel light bracket if any etc and applying one coat of aluminium paint (above ground / coping level) not exc 8 mtr long including painting of strips of height 0.3mtr each (three nos sky blue and three nos white), tightening of cross arms, clamps and street light brackets complete all as specified and directed. |
| 38 | S&F XLPE insulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100 Volts grade cross sectional area 10 Sqmm 4 core laid in trenches /ducts / fixed to wall / pole / inside panel / drawn through pipe including cable glands and terminal sockets including taking down existing cable etc all as specified and directed. Note: Excavation and earth work shall be measured and paid seperately |
| 39 | Disconnecting & taking out unserviceable one and replacement with new LED street light fittings energy saving luminaire with lens, capacity 45 watt with system efficacy (lm/w) shall be 100 lumen per watt or more lumens per watt, total system lumen not less than 4500 lumens, PF not less than 0.95, CRI not less than 70, colour temp of 5000K to 6500 K, surge protection not less than 5 KV, high pressure die cast aluminium alloy LM6 housing IP-65/66 class 1 protection, toughened glass cover, driver efficiency > 85% with constant output of current and voltage against input voltage variation 120 to 270 volt at 50 Hz (+ 5%), THD< 10% complete including taking down existing complete all as specified and directed. |
| 40 | S&F XLPE insulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 10 Sqmm 2 core laid in trenches / ducts / fixed to wall / pole / inside panel / drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed. Note: Excavation and earth work shall be measured and paid seperately. |
| 41 | S&F XLPE insulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 6 Sqmm 2 core laid in trenches /ducts / fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. |
| 42 | Disconnecting and taking out old unserviceable LED street light fitting from its existing locations and S&F LED security lights 60 W with electronic driver,multiple optics with lumen efficency not less than 110 lum/watt,High performance low wattage street light with Housing high pressure die cast aluminium, high power LED light source, IP66 protection,PDC housing with finless design and high impact resistance (IK08) or higher impact resistance, Polycarbonate / glass cover with integrated street Light optics, replaceable driver with minimum 4kV surge protection, THD < 10%, PF not less than 0.95, operating voltage 140-270Volts, 50HZ with permisible CRI range of balance energy efficiency and visibility compitable for mounting on pole and GI tubing dia 32-50mm dia, including necessary screws, nuts, bolts of suitable size and neccessary wiring from light to junction box complete all as specified and directed. |
| 43 | Disconnecting & taking out unserviceable one and S&F Synchronising electronic timer unit operated on AC 230 Volts, 24 hrs clock time for controlling street lights complete all as specified and directed. |
| 44 | M&L for cleaning of existing solar street light panels fixed above street light pole of approximate height 6 metre by using wet cloth dipped in soap water including the panel perimeter complete all as specified and directed.Notes:- (i) The contractor shall be responsible for arrange necessary conveyance vehicle, Aluminium self supporting ladder/bamboo ladder, bucket, soap powder, cloths ,Necessary T&P, Safety Belt, etc and the quoted rate shall be deemed to be inclusive of quotes rate. (ii) Contractor has to ensure serviceability of solar street light panel of DOMESTIC & TECHNICAL AREA on Daily basis in any Weather Condition at their own arrangement.(iii) Contractor shall provide conveyance to the deployed labour for maintaining the services without any extra cost to department. (iv) All safety measures and provn of all safety devices, first aid box etc shall be provided by the contractor. Contractor will be solely responsible for full safety of the persons deployed for providing the services and department shall have no liability for any type of accident / injury of any type. Unit rate quoted shall be deemed to include the cost of the same and no extra payment shall be made on this part. |
| 45 | M&L for cleaning vegetation around the LT pole completely root out from soil and clean the surface one metre around the pole of street lights complete all as specified and as directed.Note: Removing of accumulated earth depth upto 15cm cleaning / Cutting the grass with hand operated petrol/ kerosene driven grass cutting machine and removing the grass waste to outside MoD land is deemed shall be included in quoted rate |
| 46 | Disconnecting & taking out unserviceable one and S&F Power contactors 40 Amps, 4 pole, 415V,complete all as specified and as directed. |
| 47 | M&L for preparing surfaces by removing exisiting faded sky blue and white straps on PCC poles and applying a coat of sky blue / white straps painting with synthentic enamel paint, each sky blue / white straps of 30 cm height up to 1.5 m from top of PCC coping, writing pole no with white paint on black base of PCC pole by stencil measurement including applying one coat of synthetic enamel paint to clamps / cross arm / street light GI bracket fixed on pole complete all as specified and as directed. |
| 48 | Disconnecting & taking out unserviceable one and S&F PVC insulated Copper conductor cable 1.5 Sqmm, 3 Core Round Flexible for connection of street light fitting complete all as specified and as directed. |
| 49 | M&L Sub main wiring for circuit complete with 2 runs of 1.5 sqmm single core PVC insulated, unsheathed FRLS 1100 Volt grade multi stranded copper conductor cable drawn through and incl suitable size non metalic PVC conduit and accessories complete fixed surface to wall/roof/ceiling etc and 1 run of 1.5 sqmm single core PVC insulated, unsheathed FRLS 1100v grade multi stranded copper conductor cable as earth continuity conductor etc including taking down existing submain wiring complete all as specified and directed.Note:- Two runs of power cable, one run of earth conductor and one run of PVC conduit/casing capping shall be measured as one length. |
| 50 | Disconnecting & taking out unserviceable one and S&F connector suitable for fixing of cable of size cross sectional area 10 Sqmm to 25 Sqmm armoured / PVC for preventing of short circuiting of cable in junction boxes complete all as specified and as directed. |
| 51 | Disconnecting & taking out unserviceable one and S&F IP 66 Thermoplastic PC- GFS Polycarbonate weatherproof Junction Box size 255L x 205B x 112D MM with plain walls for cable entries to be drilled individually, system voltage: 415V, 50hz, The plain side walls on the four sides can be drilled and customized for cable entries from any direction. Lid fasteners shall not have screws but shall be with quarter turn locking knobs – which is well visible ( open – locked), and they will be sealable without any accessories. Cable terminal :- 25 Sq mm- 4 no with 10A SP MCB- 1 No, 6sq mm disconnected terminal- 1 no, The junction box shall fulfill the following standards Weather proof: UV resistant due to solar radiation, rainwater proof, temperature resistant.Salt water proof & shall be suitable for offshore applications. IEC 60670-22 Particular requirements for connecting boxes and enclosures. IEC 60695 – 2 – 11 Flame – retardant & Self-extinguishing. Glow Wire tested at minimum 960 deg C. IEC 60529 : IP 66 / IP 67 / IP 69 degree of protection complete all as specified and directed. |
| 52 | Disconnecting & taking out unserviceable one and S&F LED flood light fitting 70 Watts 240 Volts, (suitable for fixing on pole/ wall) with secondary optics made in pressure die cast housing with heat sink and aluminium extrusion with IP 66 class of protection complete with control driver and all accessories with high quality lenses, reflector, and toughened glass, power factor > 0.95, Luminaire lumen output - 8200lm, operating voltage range from 140V to 270V at 50 Hz AC Frequency, Temperature range - 40 to +70 deg Celsius, driver efficiency > 85%, THD<10%, CRI>70%, colour temperature 5700K, Surge protection from overvoltages 4kV internal and 10kV external, 50000 burning hours, Luminaire efficacy-110 lm/w complete all as specified and directed. |
| 53 | Disconnecting & taking out unserviceable one and replacement with new LED flood light fitting 120 Watts 240 Volts, (suitable for fixing on pole / wall) with secondary optics made in pressure die cast housing with heat sink and aluminium extrusion with IP 66 class of protection complete with control driver and all accessories with high quality lenses, reflector, and toughened glass, power factor > 0.95, Luminaire lumen output - 17600lm, operating voltage range from 140V to 270V at 50 Hz AC Frequency, Temperature range-40 to +70 deg Celsius, driver efficiency > 85%, THD<10%, CRI>70%, Colour temperature 6500K, Surge protection from overvoltages 4kV internal and 10kV external, 50000 burning hours, Luminaire efficacy-110 lm/w complete all as directed. |
| 54 | Disconnecting & taking out unserviceable one and S&F conventional type post top fitting with LED Post tops lamp fitting 1x45 W LED made die cast aluminium with innovative glare free indirect lighting distribution & IP 65 protection inlcuding fixing arrangement with suitable flanged GI pipe base and PCC fixed on floor/ground complete all as specified and as directed. |
| 55 | Disconnecting & taking out unserviceable one and S&F ALCOR LED flood light, 50 watts RGB colour changing light, 240 Volt, with high quality lenses & reflector, High grade aluminium pressure die cast housing with toughened glass cover, IP-66 class of protection, complete with control gear and all accessories including necessary PCC foundation for placing of flood light complete all as specified and directed. |
| 56 | Disconnecting & taking out unserviceable one and S&F pathway light decorative retrofit LED fitting with 9 W LED bulb including necessary excavation, PCC foundation, 1.5 mtr long GI pipe light grade 50 mm bore with base plate, cable junction box with 2 pole connector 32 A capacity including cable entry and exist knockouts, 1.5 mtr length 3 core 1.5 sqmm PVC insulated copper round cable from connector to light fitting, disposal of soil to outside MoD land complete all as specified and directed. |
| 57 | Disconnecting & taking out unserviceable one and S&F conventional type bollard fitting with LED bollard light fittings suitable for 1 x 9 watt LED bollard in rectangular shaped vicotria design with opal acrylic diffuser and IP 65 protection inlcuding fixing arrangement with suitable flanged GI pipe base and PCC fixed on floor/ground complete all as specified and directed. |
| 58 | Disconnecting & taking out unserviceable one and S&F Revolving search light 300 W LED high intensity, long range, weather proof, energy saving, instant glow, LED search light, beam range 700 meters (as per model), single LED light, efficiency >140 lm/w, PF >0.95, CCT ~ 6000K, optical grade PMMA-PC lens, narrow beam 8 degree, die cast LM6 body with air fins, toughened front glass sealed with silicon gasket, fully powder coated, wide range of working voltage 90 - 300 AC, protection against over volt & under volts, reflector lens efficiency >90%, average lux level at 10 meter is approx. 2000 - 6000 lux (as per model) with circle of approx 1 meter, confirming to LM79 & LM80. This search-light is ready to installed on rotating disc of auto revolving mechanism. Degree of protection IP65 and the stand would be suitable for mounting of search lights on its rotating disk on top side. It is made of iron / steel with epoxy powder coating weather proof paint on surface. The stand has designed so that the search light can be rotate one full round horizontally and 30 degree vertically & can be locked at any position at any time. It would be 4 nos ; high grade PVC castor wheels at bottom for easy movement on the platform with wheel locking arrangement. The height of tripod stand shall be generally 1 metre above from the bottom. |
| 59 | Disconnecting & taking out unserviceable one and S&F Integrated solar street light of capacity 12W with 2000 lumen and system lumen efficiency of more than 170 lumen per watt. The luminaire shall use highly efficient microcontroller based integrated MPPT charge controller, both charger and driver to be on same board with more than 90% efficiency of both charger and driver. High grade aluminium die-cast housing to ensure good heat dissipation. The luminaire shall have flexi mount of 0 to 15 degree to adapt to certain geography diversity. The luminaire shall be with smart self-diagnosis feature with LED indicators alongwith battery charging and deep discharging out off indications. The system shall use long time maintenance free lithium Ferro Phosphate (Li Fe PO 4) battery with BIS certification. Battery capacity of minimum 170 wh for autonomy of 24 hrs with fully charged battery. The luminaire shall be with hybrid feature (integrated/ seperated) ON-OFF switch, Outer mounting diameter of 48-60 mm. Operating temp range for light engine is 0 to +35 Dep C. operating humidity shall be upto 95%. System lumen output should be atleast 12V DC, 2000 lm. Solar panel module capacity of 12V, 35W Peak Mono-crystalline. Solar cell efficiency with min 12%. LED burning hrs to be 50,000 hrs at L70, rating of IP 65 and IK 08 to comply with UV stabilized poly carbonate front cover, colour temp of 5700K and CRI > 70 complete all as specified and directed.Notes:- (a) The unit rate shall be deemed to include for 6 mtr long MS/GI pipe of 50 mm bore medium grade including necessary excavation, PCC foundation, coping, base plate and bend to shape and size suitable for fixing of above fitting.(b)The contractor shall submit LM-80 and LM-79 report including BIS certification to Engr-in-Charge . (b) The contractor shall submit warranty certificate from manufacturer for minimum 5 years to Engr-in-Charge . |
| 60 | (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications to Engr-in-Charge . (d) The contractor shall also submit safety and performance standard compliance of IEC 60598-2-3 for road and street lights, IEC 62109-1 for power converters used in Solar Panel, EN 50530 for MPPT performance evaluation, IEC 61607 for EMC immunity, CISPR 15 for Radio disturbance characteristics, IEC 62133, IEC 61960 and UL 1642 for safety of lithium Ferro Phosphate battery and IEC 61730-1, 2 & IEC 61215 for safety of solar panel module. (d) The rates quoted deemed to be included 6 mtr long GI pipe of 50mm bore medium grade including necessary excavation, PCC foundation, coping, base plate and bend to shape and size suitable for fixing of above fitting. |
| 61 | Disconnecting & taking out unserviceable one and S&F Triglow rope light 18 mtr length IP 65 water plug and play strip light for republic day and independence day celebration show causing patriotism for India. Indian tricolour strip light - orange+white+green colour in single strip. Wattage -6W / Meter Lumen output 400lm / meter, input volt- 220V to 240V complete all as specified and directed. |
| 62 | Disconnecting & taking out unserviceable one and S&F twin core 4 Sqmm service wire 1100V grade heavy duty with PVC insulated aluminium stranded conductor served with inner sheathing of PVC tape and PVC sheathed complete all as specified and directed. |
| 63 | Disconnecting & taking out unserviceable one and S&F twin core 6 Sqmm service wire 1100V grade heavy duty with PVC insulated aluminium stranded conductor served with inner sheathing of PVC tape and PVC sheathed complete all as specified and directed. |
| 64 | Disconnecting & taking out unserviceable one and S&F twin core 10 Sqmm service wire 1100V grade heavy duty with PVC insulated aluminium stranded conductor served with inner sheatning of PVC tape and PVC sheathed complete all as specified and directed. |
| 65 | Cutting and trimming trees branches any girth and any size covering street lights mounted on pole/wall/building and cutting the branches upto 1.5 m away from the pole and disposing the same, clearing the site complete all as specified and directed.Note:Distance between 05 Nos of street light poles shall be measured as one job. |
| 66 | Disconnecting and taking out old unserviceable LED street light fitting from its existing locations and S&F LED security lights 70W with electronic driver with lumen efficency not less than 110 lumens / watt, high performance low wattage street light with housing high pressure die cast aluminium, high power LED light source, IP66 protection, PDC housing with fineless design and high impact resistance (IK08) or higher impact resistance Polycarbonate / glass cover with integrated street light optics, replaceable driver with minimum 4kV surge protection, THD < 10%, PF not less than 0.95, operating voltage 140-270 Volts, 50HZ with permissible CRI rannge of balance energy efficiency and visibility compitable for mounting on pole and Gi tubing dia 32-50mm dia, including necessary screws, nuts, bolts of suitable size and necesary wiring from light to junction box complete all as specified and directed. |
| 67 | Disconnecting and taking out old unserviceable LED street light fitting from its existing locations and S&F LED security lights 90 W with electronic driver,multiple optics with lumen efficiency not less than 110 lum/watt,High performance low wattage street light with Housing high pressure die cast aluminium, high power LED light source, IP66 protection,PDC housing with finless design and high impact resistance (IK08) or higher impact resistance, Polycarbonate / glass cover with integrated street Light optics, replaceable driver with minimum 4kV surge protection, THD < 10%, PF not less than 0.95, operating voltage 140-270Volts, 50HZ with permsisible CRI range of balance energy efficiency and visibility compitable for mounting on pole and GI tubing dia 32-50mm dia, including necessary screws, nuts, bolts of suitable size and neccessary wiring from light to junction box complete all as specified and directed. |
| 68 | Dismantling foundation of LT pole of any height by taking out from PCC foundation complete and shifting to other location as directed including fixing the pole in true vertical position including excavation and earth work, PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as base concrete and PCC 1:3:6 type C2 (using 20mm graded stone aggregate) in both foundation and coping of poles all as specified in SSR Part I-2009 and applying two coats of aluminium paint to pole surface complete all as specified and directed. |
| 69 | M&L for Meggering of LT UG cable between span to span any type connection with complete diconnection & reconnection the same for checking of fault and rectification for any size any place after disconnection of supply complete all as specified and directed. Total in Figures 0.0 23 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 3 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender