Defence Statutory Bodies & Commissions/Committees Closing in 9 days TDR #57917912

Tender For special Repair Of Bldg No P-449, Replacment Of Defective Water Supply Lines, Taps, Sanitary Fittings In Bldg No P-213 And Replacement Of Broken Wall And Floor Tiles In Bathroom & Toilets In Bldgs No P-223 At 256 Transit C And Provn Of Geys

Issued by Statutory Bodies & Commissions/Committees · Budgam, Jammu and Kashmir
Tender Value
42.28 Lakhs
Estimated cost
Bid Submission
27 Oct 2026
9 days left
EMD
85000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Budgam → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for special Repair Of Bldg No P-449, Replacment Of Defective Water Supply Lines, Taps, Sanitary Fittings In Bldg No P-213 And Replacement Of Broken Wall And Floor Tiles In Bathroom & Toilets In Bldgs No P-223 At 256 Transit C And Provn Of Geyser (50 Ltr) For Otm Accn At 162 Inf Bn (Ta) Jak Li At Old Air Field, Srinagar Under Ge 970 Ews

BOQ

Name of Work:- SPL REPAIR OF BLDG NO P-449, REPLACMENT OF DEFECTIVE WATER SUPPLY LINES, TAPS, SANITARY FITTINGS IN BLDG NO P-213 AND REPLACEMENT OF BROKEN WALL AND FLOOR TILES IN BATHROOM & TOILETS IN BLDGS NO P-223 AT 256 TRANSIT C AND PROVN OF GEYSER (50 LTR) FOR OTM ACCN AT 162 INF BN (TA) JAK LI AT OLD AIR FIELD, SRINAGAR UNDER GE 970 EWS
Sl. No. Item Description
1Taking down chowkats or frames with shutter (without taking off shutter from the frames) n. exc 1.50 Sqm Each complete all as specified and directed by Engr-in-Charge.
2Taking down chowkats or frames with shutter (without taking off shutter from the frames) exc. 1.50 Sqm n.exc 4 Sqm Each complete all as specified and directed by Engr-in-Charge.
3S&F factory made solid PVC door Frame of size 50 mmx47 mm made out of 5mm thick wood grain printed PVC sheet used instead of plain colour PVC sheet & edges will be painted to match with printed sheet reinforced MS square tube supplying & fixing in opening as per specification & drawing complete all as specified and directed by Engr-in-Chage.
4S&F factory made solid PVC moulded door shutter 28 to 30 mm thick (stiles) with 2,4, or 6 raised panel design with 2mm thick Moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specifications and drawing of page no 146 of SSR Part -II complete all as specified and directed by Engr-in-Charge.
5M&L Pressed steel frames (Factory made) made out of 1.25 mm thick black MS sheet for doors, with one or more rebates including necessary s&f lugs, holdfast, Butt hinges, lock strike plate, etc complete, size of frame 125x60mm incl bottom of Each chowkat to be welded with 2 nos 25x25x3mm thick flat iron projecting 10 cm on either side and PCC 1:2:4 type B0 12.5mm graded aggregatte as in hold fasts and bed blocks etc including necessary form work complete all as specified and directed by Engr-in-Charge. complete all as specified and directed.
6All as per Ser item No 5.00 above, but size of frame 105x60mm.
7M&L PCC 1:2:4 type B0 12 .5 mm graded aggregate cement concrete as filling to pressed steel frames complete all as specified and directed.
8S&F factory made Box Type mild steel windows side hung glazed shutters with chowkets with glazing bars to receive glass and other side of the window wire mesh shutters to receive wire mesh or wire guage dovetailed or welded and steel peg stay with and including necessary welding, reveting, tower bolt, hanlde, holdfast, wire mesh, sheet glass plain/figured and pin headed glazing fixed with putty & hinges as per Drg No. CESZ/TD-1018/2011 Sheet No 1/3 complete all as specified and directed by Engr-in-Charge.
9S&F 35 mm thick, factory made 2nd class hardwood glazed and skeleton shutters, open rebated and prepare to receive gauge etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for secruing glass/gauge etc size of member of shutter as specified in SSR Part-I Section 8 Clause 8.20(a),kiln seasoned and chemically pressure treated fitted to chowkats complete all as directed.
10S&F 35mm factory made shutters plain framed, panelled shutter with lock rail and panel of 9 mm BWP commercial ply or 12 mm to 15mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS-1003 (Part - I) kiln seasoned and chemically pressure treated complete all as specified and directed by Engr-in-Charge.
11S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples all as specified and directed.
12S&F Floor door stopper of aluminum alloy body and tongue anodized with hard drawn steel spring fixed in floor of length 150mm complete all as specified and directed by Engr-in-Charge.
13S&F mild steel 300mm, ordinary rat rail , helical rod pattern springs, including roller and roller plate complete all as specified and directed.
14S&F 200mm size aluminium anodised, barrel tower bolt of extruded section complete all as specified and directed by Engr-in-Charge.
15S&F 250 mm long aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified directed.
16S&F Extruded aluminium alloy handles 150 mm long fabricated type anodised complete all as specified and directed .
17S&F in repairs 18/19 mm thick block boards, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame-work as in shelves, partition and lineing with and including stainless steel cleats 02 number Each side complete all as specified and directed by Engr-in-Charge.
18S&F in repair 18/19 mm thick block boards, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame-work as in cupbords shutters complete all as specified and directed by Engr-in-Charge.
19S&F 0.9mm thick decorative laminate type-1, of surface finish, colour and pattern as approved fixed with approved adhesive as per marker's instructions complete all as specified and directed by Engr-in-Charge.
20S&F hasp and staple safety type 100 mm size, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed including taking down old one.
21S&F in repair Curtain rod 25mm dia or Harrison rails, mild steel chromium plated with fixing brackets, stops, rollers etc. including bracket , nobs, for Each window / door rods complete all as specified and as directed.
22M&L preparation of new or previously untreated wooden surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
23M&L two coats of synthetic enamel paint over a coat of red oxide primer after preparation of new steel surfaces of any description over 10cm in width and girth complete all as specified and directed by Engr-in-Charge.
24Demolition of unreinforced cement concrete in ground floors and paving n. exc 15cm thickness (below or above ground level) complete all as specified and directed.
25M&L for 75mm thick (1:3:6) Type-C-2 (using 40mm graded crushed stone aggregate) as in plinth protection or paving, finishing cement concrerte surface even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
26M&L for 75mm thick PCC (1:4:8) type-D2 (using 40mm graded crushed stone aggregate) as in sub base of flooring complete all as specified and directed by Engr-in-Chargre.
27M&L for 25mm thick (1:2:4) Type-B-1 (using 12.5mm graded crushed stone aggregate) as in sub base of flooring complete all as specified and directed by Engr-in-Chargre.
28Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid, dry complete
29M&L for Machine cut kota stone slab flooring 20mm thick of size not less than .034 Sqm of Each slab over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing with and including 20mm thick screed bed or bedding in cement mortar 1:6 complete all as specified and directed by Engr-in-Charge.
30M&L for Kota stone slab 20mm thick in riser of bricks steps & riser of staircase , skirting, dado and pillar laid over cement screed and jointed with pigment to match the shade of the slab including rubbing and polishing with & including backing coat in10mm thick CM (1:4) to receive Kota Stone complete all as specified and directed by Engr-in-Charge.
31M&L non skid coloured designer ceramic tiles 7 to 8 mm thick (square/ rectangular) area of Each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including 15mm thick screed bed in CM (1:6) and including dismantling of old tiles compete all as specified and directed by Engr-in-Charge
32All as per Ser item No 31.00 above, but on skirting over with and including 10mm thick backing coat in CM 1:4 and dismantling of old tiles complete all as specified and directed by Engr-in-Charge.
33M&L anti skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of Each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including 15mm thick screed bed in CM (1:4) and dismantling of old tiles compete all as specified and directed by Engr-in-Charge
34M&L glazed ceramic coloured, designer & pattern (dark & light shade combination) tiles in 450 x 300 x 7 mm thick on vertical surfaces such as dado etc set and jointed in neat cement slurry and pointed in white or colour cement to match over with and including 10mm thick backing coat in CM 1:4 and dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr-in-Charge
35M&L Granite (of any type) tiles, 20 mm thick machine cut laid over cement screed and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of the granite stone including cutting and polishing with and including 20mm thick screed bed or bedding in cement mortar 1:4 and including dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premisescomplete all as specified and directed by Engr-in-Charge.
36M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed by Engr-in-Charge.
37Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and directed.
38M&L RCC (1:1½:3) type A-1 using 12.5mm graded stone aggregate as in slab supported on wall, landings balconies, canopies, deck slabs and shelves etc complete all as specified and directed
39Use & Waste Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), completed all as specified and directed.
40M&L PCC (1:1.5:3) using 12.50 mm graded aggregate laying under bottom of the sunken floor finished even and smooth dcomplete all as specified and directed by the Engr-in-Charge.
41M&L cement concrete 1:7:12 with brick course aggregate as in filling in sunk floors complete all as directed by Engr-in-Charge.
42M&L treatment for sunken portion with and including 10mm thick cement plaster in CM 1:3 mixed with liquid WPC @ 200ml per bag of cement when concrete surface is green. Over after dry of plaster surface two coats of industrial bitumen 85/25 laid @ 1.20Kg/Sqm incl cleaning of surface over 200 micron PVC films laid when bitumen is hot complete all as specified and directed by Engr-in-Chagre. (Note : WPC , bitumen, PVC films are included in the items.
43M&L rendering 15 mm thick in CM 1:6 on brick/concrete/stone wall surfaces of any description, and finishing the surfaces even and smooth without using extra cement complete with and including taking down cement or lime plaster of any description from stone /brick/concrete wall etc incl raking out joints hacking for key scrurbbing down with water and disposing of the rubbish complete all as specified and directed by Engr-in-Charge.
44M&L rendering 15 mm thick in CM 1:4 with and including mixing of liquid WPC of approved make @ 200ml per bag of cement on brick/concrete/stone wall surfaces of any description, and finishing the surfaces even and fair complete with and including taking down cement or lime plaster or racking of pointing and scrubbing out existing finishes on wall of any for three storey bldg incl all necessary arrangement like scaffolding and masonry complete all as specified and directed by Engr-in-Charge.
45M&L rendering 10 mm thick in CM 1:3 on concrete as in ceiling/landing etc on concrete surface finished even and smooth without using extra cement with and including taking down cement or lime plaster of any description complete all as specified and directed by Engr-in-Charge.
46M&L brick work with sub class 'B' bricks straight or curved in plan exc 6 mtr mean radius built in CM (1:6) using old size bricks with and including demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engr-in-Charge.
47M&L rendering 15 mm thick in CM 1:6 on brick/concrete/stone wall surfaces of any description, and finishing the surfaces even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
48M&L rendering 15 mm thick in CM 1:4 with and including mixing of liquid WPC of approved make @ 200ml per bag of cement on brick/concrete/stone wall surfaces of any description, and finishing the surfaces even and fair complete complete all as specified and directed by Engr-in-Charge.
49M&L for preparing new/old plastered or unplastered surfaces on walls & other surface and applying two coats of oil emulsion distemper over a coat of 3 mm wall care putty with rubbing or smoothing of surface upto ture finish over a coat of water base primer complete all as specified and directed by Engr-in-Charge.
50M&L preparing new/old plastered surface of walls and applying two coats of cement based paint over a coat of cement base primer complete all as specified and directed complete all as specified and directed by Engr -in-Charge..
51M&L three coats of white wash on new/old plastered surfaces of ceiling including preparation of surfacces complete all as specified and directed by Engr-in-Charge..
52S&F 12mm thick Gypsum board for ceiling fixed with Anodised aluminium snap grid frame work for false ceiling including hangers 4mm dia GI wire (upto 1200mm centre to centre upto length as required at site) and adjusting level fixed to roof wooden member by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners complete with and including dismantling ceiling baords of any description of any thickness incl cover fillets complete all as specified and directed by Engr-in-Charge.
53S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550mpa as in roof covering /cladding to wall, fixed with self tapping screws complete with and including dismantling corrugated steel sheeting, any gauge, thickness, including nainital or similar roof coverings complete all as specified and directed.completed all as specified and directed by Engr-in-Charge.
54S&F for pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550mpa as in roof covering /cladding to wall, fixed with self tapping screws as in ridge,eaves boards, hips, velly gutter drip and straight flushing of reuired machine moulded shape and size complete with and including dismantling plain steel sheeting, any gauge, thickness, including nainital or similar roof coverings and eaves boards of any description complete all as specified and directed.completed all as specified and directed by Engr-in-Charge.
55M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed by Engr-in-Charge.
56S&F 3 Layer PPR Concealed 16mm bore pipes SDR 7.4 (PN 16) UV Stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply at PP-R& brass threaded polypropylene random fittings laid in trenches with all fittings and fixed with walls, ceilings or laid in floors complete with and including taking up or down 15 mm bore steel water tubing and connections complete all as specified and directed by Engr-in-Charge.
57S&F 3 Layer PPR Concealed 20mm bore pipes SDR 7.4 (PN 16) UV Stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply at PP-R& brass threaded polypropylene random fittings laid in trenches with all fittings and fixed with walls, ceilings or laid in floors complete with and including taking up or down 15 mm bore steel water tubing and connections complete all as specified and directed by Engr-in-Charge.
58M&L Lagging to pipes used in internal water supply (internal dia of pipe 20mm) or plumbing all round with,25min thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/Cum conforming to IS 9842 all as specified and directed by the Engr-in-Charge.
59Re-fixing old 15mm dia steel water GI tube medium grade with all fittigs / connection in new or old position and fixed with concealed to walls, ceilings or laid in floors complete with and including taking up or down 15 mm bore steel water tubing and connections complete all as specified and directed by Engr-in-Charge.
60Re-fixing old 20mm dia steel water GI tube medium grade with all fittigs / connection in new or old position and fixed with concealed to walls, ceilings or laid in floors complete with and including taking up or down 20 mm bore steel water tubing and connections complete all as specified and directed by Engr-in-Charge.
61S&F in repair vitreous China, squatting pan, Orissa Pattern, size 630 x 450 mm white, with integral foot rests (excluding flushing cistern and flush pipe) with CI trap of suitable size ( P or S type) including connection to trap and to flushing pipe, anti syphonic pipe etc complete including provision of lime concrete bedding & making good to floor complete complete all as specified and directed including taking out old one.
62S&F in repair 10 Ltr capacity PVC valveless syphonic action type flushing cistern low level white, with inlet, ball valve, float and handle including PVC flush pipe and brackets complete fixed in wall and floor to trap of WC as required and as directed.
63S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x160mm including PTMT waste copupling & waste pipe complete all as specified and directed by Engr-in-Charge.
64S&F in repair 15 mm dia CP Wall Mixer Telephonic with Crutch (Provision for hand shower) and complete set of hand shower complete all as specified and directed.
65S&F in repair 15 mm dia CP Sink Mixer with regular spout (W/M) complete all as specified and directed.
66S&F in repair 15 mm bib tap ( fancy type) , cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed including taking down old one.
67S&F in repair Chromium plated shower roses of size 125mm with or without swivel joints, any size, including fixing to steel pipe or unionincluding taking down old one.
68S&F in repair CP angle valves (half turn type) conclead type (chromium plated fancy type) 15 mm dia, cast copper alloy, screwed down, high pressure with crutch or butterfly handles, screwed both end for iron pipe or for unions complete all as specified and directed including taking down old one.
69S&F in repair Stop valves of size 20mm dia (half turn type) , cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed including taking down old one.
70S&F in repair single/multi PVC (SWR) floor trap 75mm to 110mm dia, palin with grating including joining to waster pipe, fixed in cement concrete type B-1 (1:2:4) using 20mm graded broken stone aggregate complete all as specified and directed by Engr-in-Charge.
71S&F in repair 15 mm dia PVC connections, 600 mm long with PTMT nuts of suitable size at two end complete all as specified and directed including taking out old one.
72S&F in repairs 600 x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers.
73S&Fin repair towel rail 600 mm long of PTMT fixed with and incl Chromium plated brass screws and wooden/plastic cleats (Minimum weight 190 gms).
74S&F Corner shelves fancy type complete all as specified and directed including taking out old one completed all as specified.
75S&F Stainless steel kitchen rack of size of 900 x900 x 250mm thickness not less than 0.8 mm complete all as specified and as directed.
76S&F in repair 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls/floors with necessary MS clamps including taking down old pipes all as specified and as directed
77S&F 75 in repair mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls/floors with necessary MS clamps including taking down old pipes all as specified and as directed
78S&F 110 mm PVC (SWR) access door bends any radius including taking down old all as specified and as directed
79S&F 75 mm PVC (SWR) access door bends any radius including taking down old all as specified and as directed
80S&F 110mm PVC (SWR) junction single,(Single T) equal or unequal provided with access door complete all as specified and directed by Engr-in-Charge.
81S&F 75mm PVC (SWR) junction single,(Single T) equal or unequal provided with access door complete all as specified and directed by Engr-in-Charge.
82S&F 110mm PVC (SWR) vent cowl complete all as specified and directed by Engr-in-Charge.
83S&F rotational moulded polythene water storage tank 500 ltrs (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I with and including dismantling water tank of capacity exceeding 250 liters but not excedding 500 Ltrs and including 20mm ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule & nipple suitable for HDPE water tank (Min weight 15mm-38 gms/20mm-45gms/25mm-65gms) complete, all as specified and directed by Engr -in-Charge.
84Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out from hard dense of soil complete all as specified and directed by Engr-in-Charge.
85M&L for returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engr-in-Charge.
86Removing excavated material exc. 250 m but n exc. 500 m anddepositing where directed at a level n. exc 1.5m above the starting point complete all as specified and directed by Engr-in-Charge.
87M&L Reinforced NP2 pipe of 100 mm dia laid in trenches and jointed on concrete bed including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 with and including demolition and breaking up existing drain pipes of any description ( like PVC, salt glazed ware, AC or reinforced concrete) set in cement mortar complete all as specified and directed by Engr-in-Charge.
88M&L Reinforced NP2 pipe of 150 mm dia laid in trenches and jointed on concrete bed including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 with and including demolition and breaking up existing drain pipes of any description ( like PVC, salt glazed ware, AC or reinforced concrete) set in cement mortar complete all as specified and directed by Engr-in-Charge.
89Cutting into existing manhole removing existing drain making good to wall and rendering cutting out branch channel and making good benching for 100mm dia pipe in cement concrete 1:2:4 complete all as specified and directed by Engr-in-Charge.
90Cutting into existing manhole removing existing drain making good to wall and rendering cutting out branch channel and making good benching for 150mm dia pipe in cement concrete 1:2:4 complete all as specified and directed by Engr-in-Charge.
91M&L for precast RCC (1:1½:3) type A-1 (using 12.5mm graded crushed stone aggregate) as in manhole cover slab or drain cover and similar article with plain faces, set in cement 1:4 complete all as specified and directed by Engr-in-Charge.
92S&F TMT Mild Steel bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-Charge..
93M&L for cement concrete (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed by Engr-in-Charge.
94Dismanting post of struts (wood,steel or RCC) any section,including taking out embedded portion in natural ground and making good the disturbed ground complete all as specified and as directed
95M&L for Cement concrete in foundations, filling and mass concrete 1:3:6 Type-C-2 (using 40mm graded stone crushed stone aggregate) finishing cement concrerte surface even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
96S&F Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled & countersunk for balusters running bars, for doors,balusters,nosing to steps including embeding in concrete & screwing etc. wind ties for roof including securing bolts; posts & struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., & similar work conforming to Fe 290-0 Gde E-165
97Dismantling fencing wire mesh n.exe 4Kg, any type and in any position & separating them the serviceable & unserviceable materials and removing the unserviceable wire mesh from work site as directed.
98Supply only Chain link MS galvanised fencing, any size or type complete all as specified and as directed.
99Fixing only chain link fencing including line wire any mesh, size and type to any type of standards rails staining bolts etc including provision of binding wire complete all as specified and as directed
100S&F Mild steel screw bolts (machine made) with hexagonal /square heads at one end & screwed the other/ screwed both ends, Each screwed end to be fitted with washers & one hexagonal or square nut, length of bolt exc 5cm but n exc 10cm long dia of shank 11 to 15 mm fixing complete all as specified and as directed
101Supply only 10mm dia mild steel plain round bar Fe-290(Gde E-165) as in line wire for chain link fencing completed all as specified and directed.
102M&L Machine pressed precast, cement concrete interlocking paver block with gray cement and pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as specified and as directed.
103M&L Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
104S&F in repair Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings & straining & fixing to any type of standard rails straining bolts, including, securing or tying at crossings with & provision of galvanised mild steel wire, staples or steel pins, etc. as directed (Each line wire to be measured).
105M&L for On site LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete for 20 users complete all as specified and directed.
106M&L Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.20m dia X 3.00m deep as per TD of CE 31 Zone completed all as specified and directed.
107S&F 125 mm butt hinges medium weight cold rolled mild steel and fixed with screws or weld to steel frame complete all as specified and directed.
108M&L for sand filling 25mm thick for sand cushioning for laying of interlocking paver blocks under floors/path including watering and consolidation as required complete all as specified and directed.
109Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
110M&L for applying two or more coats of Acrylic Interior Emulsion paint on new/old surface of wall, approved manufacturer, of required shade and colour over a coat primer complete ,as per mnufactures specification complete all as specified and directed. Note Application of primer and distemper to be carried out through roller (Mechanical means )
111S&F vitreous China wash hand basin (pedestal) white of size 550X400mm excluding taps, waste chain and plug and porcelain stopper and waste pipe & waste coupling including all necessary fitting and fixtures complete all as specified
112S&F pillar taps,15mm dia fancy type with capstan heads,chromium plated screwed down high pressure with or without lettered HOT or COLD with long screwed shanks and fly nuts,screwed for iron pipe and fixed.
113S&F in repair viterous china Urinal full stall type, white including providing & fixing plugs, beddinjg urinal against wall in cement mortar (1:2) securing to plugs with & incl 60mm long brass screws, pointing around urinal back in cemnet, with & including PTMT grating and union for discharge pipe including waste pipe of polythelene of low or high density or PVC 32mm dia, complete all as specified & directed.
114S&F in repair urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gmscomplete all as specified & directed.
115S&F rotational moulded polythene water storage tank 1000 ltrs (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I with and including dismantling water tank of capacity exceeding 250 liters but not excedding 500 Ltrs and including 20mm ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule & nipple suitable for HDPE water tank (Min weight 15mm-38 gms/20mm-45gms/25mm-65gms) complete, all as specified and directed by Engr -in-Charge.
116Taking down carefully copper/aluminium point wiring from wooden battan/ conduits or from the wall by chasing/cutting (light, fan, socket or power) completely including (fittings such as switches, ceiling roses, pendants, regulator, sockets etc. to be measured separately) and making good disturbed surfaces of walls, floor etc.
117Taking down old submain wiring of any size and make from the site and making good surface complete all as specified and directed.
118Taking down old MCCB,TPN DBs , SPN DBs alongwith SP/SPN MCB & Main Switch/enclosure box of any make and type from the site and making good surface complete all as specified and directed.
119M&L for Point wiring complete with 1.5 Sqmm single core PVC insulated FRLSH cable 1100 volts grade with multi stranded copper conductor drawn through new PVC conduit 20 mm dia medium grade ISI marked and all conduit accessories concealed in walls/ceiling/fixed to roof/truss/columns etc and including provision of 1.5 Sqmm PVC insulated copper cable FRLSH as earth continuty, fabricated branded modular metal flush box duly make embossed, concealed in walls with suitable modular cover plate for housing of mudular switches , socket out let and fan regulators etc, complete all as specified and as directed for the followings :- One light/fan point controlled by one way switch.
120All as per Ser item No 119.00 above, but One bell point controlled by one way switch.
121All as per Ser item No 119.00 above, but One 3 pin socket outlet 5 Amp independent.
122All as per Ser item No 119.00 above, but One 3 Pin socket outlet on the same board.
123All as per Ser item No 119.00 above, but with 3 pin socket outlet, 15 A, independent, with PVC copper conductor 4 Sqmm Size.
124M&L for point wiring complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn through and including PVC casing & caping on surface of wall, not less than 25mm width confirming to IS 9537 (Part-III) 1983, including all accessories like bend, tees, junction boxes etc., 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc and including sunken type pressed steel terminal box with 1.8 mm wall thickness, of suitable size for flush type switch with cover plate, cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate complete : One light/fan point controlled by one way switch.
125All as per Ser item No 124.00 above, but One bell point controlled by one way switch.
126All as per Ser item No 124.00 above, but One 3 pin socket outlet 5 Amp independent.
127All as per Ser item No 124.00 above, but One 3 Pin socket outlet on the same board.
128All as per Ser item No 124.00 above, but with 3 pin socket outlet, 15 A, independent, with PVC copper conductor 4 Sqmm Size.
129M&L Submain wiring with two run single core 6 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 volts grade in concealed New PVC conduit 25mm dia ISI marked alongwith one run of 6 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main DB and testing on completion etc complete all as directed.
130S&F in repair Sub main wiring with two runs of 4 Sqmm single core PVC insulated FRLSH cable 1100 volts grade, multistranded copper conductor cable with one run of 2.5 Sqmm single core PVC insulated FRLSH cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid in concealed New PVC conduit and conduit accessories complete all as specified and directed.
131M&L in replacement Modular switch, 6 Amps 1 Way,1 module, 230V AC complete all as specified and directed by Engineer in charge.
132M&L in replacement Modular Bell push, 6 Amps, 1 module 230V AC complete all as specified and directed by Engineer in charge.
133M&L in replacement Modular switch, 16 Amps 1Way, 1 module with modular plate light marking 230V AC complete all as specified and directed by Engineer in charge.
134M&L in replacement Modular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified and directed by Engineer in charge.
135M&L in replacement Modular socket outlet 2/3 pin 6/16 Amp universal socket 2 module complete all as specified and directed by Engineer in charge.
136S&F DB for MCB Protected Socket 15 Amps , PVC Plastic Base (white) with Plug top 25 Amps & MCB SP 32 amps complete all as specified and directed.
137M&L ceiling rose 3 phase PVC polycorbonate,isolated body completed all as specified and directed.
138M&L bell ding dong AC,230 volts,single pole all as specified and directed by Engr in Charge.
139S&F LED batten luminaire surface mounted ,4 feet (Warm/ Warm White) system wattage of not less than 20 Watts with lifetime of 25000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 4000 to 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level > 120 Lumens/watt, filcker free (Ripple less than 5%) and including connecting up with PVC sheathed 1.5 Sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed with 2 years of replacement warranty on fittings complete all as specified and directed.
140S&F LED batten luminaire surface mounted 2 feet system wattage of not less than 10 watts and not less than 1000 lm with life time of 25000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 4000 to 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, Class - 1, SDCM <5 short circuit and over circuit protection, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥120 Lumens/watt, filcker free (Ripple less than 5%) and including connecting up with PVC sheathed 1.5 Sqmm 3 core copper conductor flexible wire fixed with 2 years of replacement warranty on fittings complete all as specified and directed.
141S&F 10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 100 lm/W with a life class of 25,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6500K, Surge protection of 4.0 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
142S&F Electric water heater storage type (Geyser) vertical type with suitable size of fastner and incl provision and connecting up of SS braided pipe with adopter for inlet and outlet water connection, having adjustable knob for temperature control and inner tank should be glass line coated complete all as specified of capacity 25 ltr having heating element up to 2 KW and not less than 5 star rating. Against def
143S&F 60 W High efficient LED Street light fitting with pressure die cast Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie should more than 80lm/W. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of sutable dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on wall fixed complete as specified and directed.
144S&F Exhaust fan 300 mm sweep(steel Body) , 900 RPM, steel body including metalic blade , single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 Sqmm for connection from ceiling rose to fan complete all as specified and as directed.
145S&F Ventilating Fan 250 mm sweep, 900 RPM, non metallic resin body, single phase 230 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 Sqmm for connection from ceiling rose to fan complete all as specified and as directed.
146M&L for breaking old existing wall and making a provn for fixing of 300 mm sweep exhaust fan/250 mm fresh air fan including making good to the disturbed wall/ portion and matching with existing colour.all as specified and directed.
147S&F ceiling fans complete with blade, down rods, electronic regulator and accessories rated speed not less than 330 RPM, 230 V, 1200 mm sweep, air delivery not less than 220 CMM BEE five star rated voltage range 140 - 280 volts power factor > .9 and THD < 20 % with brushess direct current motor (BLDC) all as specified and directed by Engr in Charge. Note : Hook & Down rods length should be as per site requirement.
148M&L earthing complete with GI electrode 600x 600 x 6mm, thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below normal ground level (with top edge of earth plate not less than 1.50 mtr below normal ground level connected to GI strip 32x6mm as earthing lead by means of bolt nuts, check nuts, and washers of brass connected including gun metal or phosphorus bronze of sixe 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25 mm long hexagonal head screwed all as specified including excavation and earth work and disposal of surplus soil incl 40 mm GI tubing light grade and necessary fitting for protection of GI strip incl laying of charcoal dust and common salt PPC (1:2:3) type C-1 (using 20mm graded stone aggregate) for earth pit with 40 x 40 x 6mm MS angle iron frame for cover 40 mm thick (1:2:4) type B20 using 12.5 mm graded stone aggregate reinforced with 8 mm dia round bar @ 75mm C/C both way with MS handle 20mm dia plastering 15mm thick CM (1:6) internally and upto 150mm below ground level externally PGL funnel with ground wire mesh 20mm dia Med grade GI pipe for watering complete all as shown on electrical plate No 3 of SSR Part-1 2009 and connected in earth test incl testing completed all as specified and directed.
149S&F MCB DB SPN 8 way Horizontal, IP - 43 Protection single door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as specified and directed.
150Supply, installing, testing and commissioning factory made and tested LT Panel Indoor type, platform mounted of size: 800 X 200 X 1200 mm ( LxWxH ) suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated electrolytic Copper bus bars of capacity 250 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, IP-42 and made out of 2.00 mm thick CRCA mild steel sheet Wall mounted type, front opening type with aprons for cable entry, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 Sqmm. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey RAL- 7035 shade complete all as specified and directed by Engineer-in-Charge. The scope of work also comprising of the following:- BUS BAR CHAMBER:- (a) 250 Amp TPN, Copper conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings.INSTRUMENT CHAMBER:- (i) Volt Meter,96mm,flush type rated 0-500V, Digital type with Volt Meter selector switch- 01 Set. (ii) Amp Meter,96mm,flush type rated 0-200A, Digital type with suitable size C.T's, and Amp Selector switch- 01 Set (iii) RYB Phase indicating light LED type with MCB 2A SP C Series- 1 Set of three. INCOMING:- (i) MCCB 160 Amps 25 KA , 4 Pole with adjustable thermal magnetic release=01 No., Make of MCCB:- Siemens / Legrand/ Schneider.OUTGOING:- (i) MCB 2 Pole 63 Amps, 415 volts , 50Hz, 10 KA = 04 Nos. , Make of MCB:- Siemens/ Legrand/ Schneider. (ii) MCB 2 Pole 10 Amps, 415 volts , 50Hz, 10 KA = 01 Nos. , Make of MCB:- Siemens/ Legrand/ Schneider. (iii) Provision for Single phase electric meter (v) Panel wiring for control circuit with copper flexible 1.5 Sq mm & power wiring minimum 10 Sqmm flexible.Note :- (i) Marking of Flat Nos on outgoing feeders of LT Panel. (ii) Time duration for replacement of LT Panel should not be more than 4 Hours. (iii) Rate quoted are deemed to be inclusive of all the fixture /fittings cater above
151S&F MCB ISOLATOR SPN 40 Amp, 'C' curve, 16 KA, 50 HZ, 240 volts completed all as specified and directed.
152S&F MCB SP 6-32 Amps 240 volts 'C' curve series 10 KA 50 HZ complete all as specified and directed.
153M&L in replacement Modular socket outlet 2/3 pin 6/16 Amp universal socket 2 module complete all as specified and directed by Engineer in charge.
154M&L ceiling rose 3 phase PVC polycorbonate,isolated body completed all as specified and directed.
155S&F in repair factory made epoxy powder coated Load line Distribution Board TPN-4 ways with double door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including insulated 200 Amp copper bus bar, Isolated neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN- MCCB 125/160 Amp as incomer and 32 to 63 Amp SP MCBs outgoing complete all as specified and conforming to IS : 8623, completed all as specified and directed.
156S&F in repair MCCB 25 TO 100 Amp, FP 415 volts 16KA, 3 pole 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge.
157Taking down old unservicable cable of any size or type from any description (trenches, walls, ceilings., etc) from various locations, including any short length, all as specified & directed.
158Supply and Laying jointing & testing XLPE insulated PVC sheathed armoured heavy duty electric cable with stranded aluminium conductor 1100 volts grade, cross sectional area 70 Sqmm 3.5 core complete fixed to floor/walls/ceiling with suitable size of clamp/saddles complete all as specified and directed.
159Supplying, laying and cushioning for cable protection in trenches 8 cm deep before laying cable and 15 cm deep over the cable including well punning complete all as specified and dierected
160Supplying, laying sub class 'B' bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection complete all as specified and directed.
161S&F in replacement GI tubing light grade in trenches/fixed to wall/ceiling including required GI fitting of size 40mm dia complete all as specified and directed
162Taking out/taking down old unserviceable damaged GI/PPR pipe of following sizes from trenches/Wall/roof including removing of fittings all as directed fby Engineer in Charge :- 50 mm dia completed all as specified and directed.
163All as per Ser item No 162.00 above, but 25 mm dia completed all as specified and directed.
164S&F 3-layer PP-R (Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply of external dia 50 mm including all PP-R plain & brass threaded polypropylene random fittings, band, elbow, union,nipplesand short pieces fixed complete to walls, ceilings or in floors etc completed all as specified and directed.
165S&F 3-layer PP-R (Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply of external dia 32 mm including all PP-R plain & brass threaded Polypropylene random fittings, band, elbow, union,nipplesand short pieces fixed complete to walls, ceilings or in floors etc completed all as specified and directed.
166M&L Lagging on pipes of internal dia upto 32 mm, used in external water supply or plumbing all round with, 40mm thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/Cum conforming to IS 9842, provided with chicken mesh wire netting 25 gauze 20mm mesh and finally covering with plaster of pairs , complete, all as specified and directed.
167M&L Making connection of PPR distribution branch with PPR main of sizes 16 mm to 40 mm by providing and fixing tee including cutting and making fusion joint etc complete all as specified and directed.
168M&L Making connection of PPR distribution branch with PPR main of sizes 50 mm to 75 mm by providing and fixing tee including cutting and making fusion joint etc complete all as specified and directed.
169S&F PP-R Gate valves (brass insert) ISI marked of external dia 50 mm as per requirement of the site and as directed by Engineer-in Charge.
170S&F PP-R Gate valves (brass insert) ISI marked of external dia 32 mm as per requirement of the site and as directed by Engineer-in Charge.
171Supply and Laying jointing & testing XLPE insulated PVC sheathed armoured heavy duty electric cable with stranded aluminium conductor 1100 volts grade, cross sectional area 16 Sqmm 2 core complete fixed to floor/walls/ceiling with suitable size of clamp/saddles complete all as specified and directed.
172M&L for cutting the existing GI tube pipe for insertation of new Tee branches, reducers in any position of 15 mm dia pipe line complete all as specified and directed.
173S&F Water heater storage type (Geyser) vertical type with suitable size of fastner and incl provision and connecting up of SS braided pipe with adopter for inlet and outlet water connection, having adjustable knob for temperature control and inner tank should be glass line coated competed all as specified of capacity 50 ltr having heating element 2 KW and not less than 5 star rating completed all as specified and directed.
174S&F sheet metal enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 20 Amp 220 volts, 50 Hz, 10KA breaking capacity complete all as specified and directed.
175S&F tubes, 'medium grade', galvanised, with all fitting; laid in trenches, fixing on wall complete of bore 15mm dia all as specified and directed.
176S&F Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed of cap 15mm dia complete all as directed.
177S&F PVC Hot and Cold connection 15 mm size with PTMT nuts of length 300 mm completed all as specified and directed.
178S&F Fancy type 15mm dia Stop valves, cast copper alloy,screwed down,high pressure,with crutch orbutterfly handle,screwed bothends for iron pipe or for unions and fixed all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57917912
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 42.28 Lakhs
LAST DATE 27-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repair Of Bldg No P-449, Replacment Of Defective Water Supply Lines, Taps, Sanitary Fittings In Bldg No P-213 And Replacement Of Broken Wall And Floor Tiles In Bathroom & Toilets In Bldgs No P-223 At 256 Transit C And Provn Of Geyser (50 Ltr) For Otm Accn At 162 Inf Bn (Ta) Jak Li At Old Air Field, Srinagar Under Ge 970 Ews
Basic Detail
Tender No GE 970 EWS-85(T)/2026-27
Bidding Type Tender
Location
City Budgam
State Jammu and Kashmir
Key Dates
Publish Date 08 Oct 2026
Submission Date 27 Oct 2026
Open Date 29 Oct 2026
Finance
Tender Value 42.28 Lakhs
Tender Fee 500
EMD 85000
Exemption Available
Document List
BOQ_888862.xls
ea14d7d8-d205-4b33-bbfd-bfde5eceb2ed.html
Tender85T_merged.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 08, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Oct 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_888862.xls

html

ea14d7d8-d205-4b33-bbfd-bfde5eceb2ed.html

pdf

Tender85T_merged.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender