Defence Statutory Bodies & Commissions/Committees Closing in 11 days TDR #57917906

Tender For Provision Of Independent Feeder From Mseb At Site R At Af Station Thane

Issued by Statutory Bodies & Commissions/Committees · Thane, Maharashtra
Tender Value
84.62 Lakhs
Estimated cost
Bid Submission
09 Nov 2026
11 days left
EMD
1.51 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thane → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provision Of Independent Feeder From Mseb At Site R At Af Station Thane

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 26-Oct-2026 date corrigendum Date 09-Nov-2026

BOQ

Name of Work:- PROVISION OF INDEPENDENT FEEDER FROM MSEB AT SITE R AT AF STATION THANE
Sl. No. Item Description
1Excavation in trenches by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) for laying of UG cable etc in getting out any type soil and levelling of bottom surface to required level including getting out and disposal of excavated earth lead upto 50 Mtr and lift upto 1.5 Mtr complete all as specified and as directed
2Excavation in trenches by mechanical means (Hydraulic excavator) means over areas additional 1.5 m or part thereof in depth beyond the first 1.5 m. for laying of UG cable etc in getting out any type soil and levelling of bottom surface to required level including getting out and disposal of excavated earth lead upto 50 Mtr and lift upto 1.5 Mtr complete all as specified and as directed
3Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 Cm thick soft / loose soil complete all as specified and as directed.
4Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed
5Supply and lay for double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 14930 (Part I and II) for protection of underground cables of following size nominal outer dia & nominal inner dia with all fittings laid in trenches / road/ nallah or fixed along wall for cable protection complete all as specified and as directed.of the following:-
6Nominal outer dia 160 mm & nominal inner dia 136 mm dia.
7Nominal outer dia 200 mm & nominal inner dia 170 mm dia.
8S & F for Cable route indicator / Marker made up of PCC Block in cement mortar 1:3:6 (20 mm graded aggregrate) of size 900 x 300x 100 mm thick with DANGER/ 22 KV/33 KV CABLE /MES embossing on cable route Indicator / Marker including painting as per approved colour and buried in ground 45 Cms including necessary earth work ( as required / ordered at site) complete all as specified and as directed.
9M & L for Cement Concrete PCC 1:4:8 (40 mm graded stone aggregate), type D2 as concrete in foundation of Poles and filling and mass concrete etc, including formwork (as if required), complete all as specified and as directed.
10M & L for Cement Concrete PCC 1:3:6 (20 mm graded stone aggregate) as in coping of pole etc including form work & finishing the surfaces even & smooth with out using extra cement complete all as specified
11Supplying, install and erect in for true vertical position steel tubular swaged welded pole for provision of 4 pole structure complete with MS base plate 6mm thick and of size 300 x 300 mm, final taper, pole cap, bolts, nuts, washers & screws etc. pole made out of ERW MS tubing conforming to IS-2713 part-II type 410 SP-55 (11 metre long) including of holes of reqd Nos and size for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embedded in concrete, painting with synthetic Enamel Paint (First Grade/quality) black & yellow colour at lower portion of exposed pole starting from plinth block band of 1200 mm height (4 Nos each Strip of 150 mm width), painting pole No by the black paint by stenciled letters/ figures of 8 cm height complete all as specified and directed.
12M&L for Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20 cm size complete all as specified and directed.
13Supply and lay test and commissioning HT XLPE cable (22 KV), insulated, screended, PVC bedded, galvanised steel strip or wire armoured, electic power cable (heavy duty) with multistaranded aluminium conductor, conforming to IS : 7098 (Part II), 22000 Volts \\"E\\" grade of size / cross sectional area 3 core x 240 Sq mm laid in trenches/ ducts/under plinth floors passing through pipes etc, fixed on wall complete all as specified and directed.
14Supply and lay test and commissioning HT XLPE cable (33 KV), insulated, screended, PVC bedded, galvanised steel strip or wire armoured, electic power cable (heavy duty) with multistaranded aluminium conductor, conforming to IS : 7098 (Part II), 33000 Volts \\"E\\" grade of size / cross sectional area 3 core x 240 Sq mm laid in trenches/ ducts/under plinth floors passing through pipes etc, fixed on wall complete all as specified and directed.
15Supply and fix for cable jointing kit for 22 KV grade cable for outdoor termination, cold shrink type, joint complete with joining material and accessories suitable for 3 core XLPE armoured, aluminium conductor cable of size 3 core x 240 Sq mm complete all as specified and as directed.
16Supply and fix for cable jointing kit for 33 KV grade cable for outdoor termination, cold shrink type, joint complete with joining material and accessories suitable for 3 core XLPE armoured, aluminium conductor cable of size 3 core x 240 Sq mm complete all as specified and as directed.
17M & L for Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two Nos GI washers and one GI nut, 150 mm height, 150 mm dia for 11000 volts grade complete all as specified and directed.
18M & L for Disc type insulator , porcelain, vitreous, white, brown or green 145 mm high and 225 mm dia ball and socket type single disc assembly for tension with tension clamps for conductors working pressure for 33000 volts grade complete all as specified and directed.
19S & F for anti climbing spikes type fabricated out of MS flat of 50mm x 6mm in two parts with 14 Nos 230 mm long 12 mm dia spikes sharpened edge and including nut,bolts & washers and welding made to shape to suit the cross section of pole including two coat of first grade aluminium paint over a coat of red oxide primer complete all as specified and directed.
20M&L for stringing and fixing in position of ACSR conductor of any size as per site requirement including provision of aluminum binding wire complete all as specified and directed.
21Supply and fixing for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including two coats of aluminium/silver paint over and including a coat of red oxide primer complete all as specified and directed.
22Supplying, installing, fixing, commissioning and testing of Air break gang operated triple pole switch out door type with 15 Nos polymer based insulators suitable for 33 KV, HT, 50 Hz of capacity 400 Amps rating with polymer based drop out fuse assembly with fuse carrier, fuse element (set of 3 Nos) mounted insulators and fitted on steel frame horizontally operated (rotory type) mechanism from ground level consisting of operating rod of 25 mm bore heavy grade GI pipe of suitable length worked from ground level and with locking arrangement including pad locks, flat iron clamp 50 mm x 6 mm and MS channel of suitable size and length for fixing GOD including bolts, nuts, and washers complete all as specified and directed.
23Supply and fix Lightening arrestor HT 33 KV, non linear resistor type conforming to IS 3070 (part-1) 1993 complete, line discharge class-3, nominal discharge current 65 KA (peak), 34 KV rated system, voltage peak value high current implus of 4/10 micro Sec wave shape 100 KA (peak) assembly suitable for 33 KV, long duration descharge class-II with insulation level 28/ 75 KV and mounted on hot dip galvanized steel structure including all clamps, nuts, bolts and washers and connecting to earth with 4 mm dia GI wire complete all as specified and directed.
24Supply, installation, testing and commissioning Outdoor type (IP 54), 01 way RMU (Ring Main Unit) 33 KV, 630 Amps, 25kA-3 Sec, IP54 SF6 insulated, One side Extensible, consisting of One No (01) Motorised Vacuum Circuit Breaker (CICO) and Metering Panel Bus PT with Top LV, Battery & Battery charger (Configuration V+M) inside robotically welded stainless steel 304 (Non Ferrite Non Magnetic Grade) tank having min thickness 2.5 +/- 0.5mm with IP 67 degree of protection and enhanced BIL of 36/70/170 kVp internally to manage voltage surges and Air Insulated Metering Module of Class-0.5. RMU should be provided with internal busbars, as well as earthing busbars of electrolytic grade copper, padlock provisions complete with all accessories. The complete RMU must be type tested for internal arc 25 KA for 1 sec with AFLR classification for gas tank and cable chamber as per IEC 62271-200. HT RMU shall preferably have on-site-repairability features such as site replaceable bushing/ coupling/ mechanism and gas refilling to have very less downtime in the event of bushing breakage and restoration can be done at site immediately without sending the RMU to OEM Works, the Vacuum Interrupter must be RMU manufacturer's own make. The earthing busbar shall be provided inside each cable compartment for solid earthing of cable shields. The outer hinged main door should cover entire front of switchgear including cable doors for providing fail-safe protection. The unit shall include the following with all necessary standard fittings complete all as specified and as required at site
25Description of Srl Item No 24.00 Contd/- : (a) Vaccum Circuit Breaker shall consist of the following accessories:-(i) Microprocessor based Numerical Protection Relay for Circuit Breakers - REX615, Feeder Protection and Control Relay, Protections 50, 51, 50N, 51N, 46, 49, 67, 67N, 32, 27, 59, 25, 81U, 81O, 95 Measurement for 3I,I0,3U,U0,Kw,KVA,PF,Hz,Kwh, 16 DI + 10 DO, One front RJ45 Port, One Rear RJ45 Port for IEC-61850 Protocol, Drawout Type with CT Shorting feature, Graphical LCD Display.(ii) Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder(iii) SF6 Gas pressure indicator on the gas tank(iv) Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO and suitable for 10,000 mechanical operation(v) CT shall be minimum 50-100/1A ,2.5VA , 5P10 - 3 Nos. for protection(vi) CT shall be minimum 50-100/1A ,2.5VA , Class 0.5 - 3 Nos. for metering(vii) Touch proof cable termination kit - 2 sets(viii) 2 x12 Volts, 26 AH Battery with Charger - 1 Set(ix) Bus VT shall be 33KV/V3/110V/V3, 20VA , Class 0.5 - 3 Nos. for metering(x) Auxiliary VT shall be 33KV/230, 500VA for AC supply input to Battery Charger
26Description of Srl Item No 24.00 Contd/- (xi) Capacitive voltage indication fixed type system as per IE(xii) Interlocked cable box for front termination of the cable suitable upto 3 core 240Sqmm, 33 KV XLPE cable.(xiii) Safety interlocked to prevent access to cable termination in live-condition. (xiv) Cable covers with self interlocking mechanism between doors, earth switch, disconnector and VCB(xv) Necessay interclocking arrangement for safety and operations(xvi) One no. operating handle for manual operation and one no. manometer(xvii) Safety interlocks shall be provided as per relevant IEC/ IS standards and manufacturer's directions(xviii) Above switchgear shall confirm to all relevant IEC/ IS standards Note :- Rate Quoted by the firm for this item should include the cost of the following:-(i) PCC work/ any civil work for foundation required for errection of VCB and other accessories all as standard norns.(ii) Contractor shall submitt type test certificate to the Engr-in- Charge/ GE for approval for approval for placing the order.(iii) Any other item required to complete the job for any Technical requirement as per CEA/ NPERC.(iv) VCB shall be inspected by inspecting officer nominated by accepting officer at Manufacturer factory and all routine test pertaining to IS shall be carried out.
27Supply, install, test and commission for step down transformer, outdoor type, and conforming to IS 2026, plinth mounted, HT 33/ 22 KV, 50 Hz, delta/star connected, vector group DYN -11 double copper wound, Class 'A' insulation, ONAN, remote type On Load Tap Changer (OLTC), Remote Tap Cubical Changer (RTCC) Panel+Automatic Voltage Regulator (AVR) facility on HT side to vary secondary voltage from minus 10 % to plus 10% in steps of 1.25 %, continuous rating of capacity 500 KVA including bushing on HV end cable box on LV side. Temperature rise of OIL/ WDG by Thermometer/ Resistance method over specified ambient of 50°C is 50°/55°C over an ambient of 50°C , No Load Loss is 1.5 KW (IS Tolarance), Full Load Loss is 7.50 KW (IS Tolarance), and Impedance at rated Current at 75ºC is 6% (IS Tolarance) or specified in IS 1180/ 2026 as applicable, The Transformer shall be complete with all standard fittings and accessories, gauges, first fill of transformer oil, filtered & dehydrated oil etc, complete all as specified and directed and comprising of the following accessories :-
28Description of Srl Item No 27.00 Contd/- (a) HV side bare bushing suitable for OH conductor (consisting of 3 Nos porcelain HT bushings with brass/ gun metal bushing rods complete with nuts and washers).(b) One cable box on secondary (LV) side consisting of 3 Nos porcelain bushing with GM bushing rods complete with GM nuts, and washers with one No cable gland suitable for reception of outgoing HT armoured cables of suitable size.(c) Oil conservator tank with filter type, drain valve and oil level gauge.(d) Dehydrating breather (Silica Gel Breather) with first fill of dehydrating agent.(e) Thermometer pocket on tank cover.(f) Buchholz Relay (having Contacts for Alarm & Trip), OTI (having Contacts for Alarm & Trip), WTI (having Contacts for Alarm & Trip)(g) Marshalling Box (having TTB Only)(h) One No 100mm dia dial type thermometer vapour pressure type having range 0-120 degree centigrade with temp reading pointer, max temp indicator and resetting device.(j) Magnetic Oil Level gauge.(k) Bottom Oil filter cum drain valves.(l) Top Oil filter valve, Inspection Cover with cap/plug with connections complete.(m) Lifting lugs.(n) Air relief valve plug (Air release Plug), Explosive vent,
29Description of Srl Item No 27 .00 Contd/- (o) Four Nos plan solid cast steel detachable rollers (Bi directional Wheels).(p) First fill of fresh oil conforming to relvant IS and tested upto 50 KV dielectric strength upto top of core. Routine Testing as per IS1180/ IS-2026(r) Rating plate with terminal markings.(s) Two earthing terminals on tank/ tank cover to facilitate fixing of 32 x 6 mm GI eath strip.(t) Provision of 2 Nos danger boards 250 x 200mm size made out of 1.6 mm thick MS plate, vitreous enameled white, with letters, figures of vltage and conventional skull and bones in signal red colour, one at HT side and other on LT side.(u) Any other fittings/accessories so as to confirm the whole transformer to IS-2026.(v) PCC work/ any civil work for foundation required for errection of transformer and other accessories all as standard norns.
30Material and labour for boring hole under the road/pavment/hard standing with the help of trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure not less than one metre below ground level complete all as specified & directed.
31M & L for maintenance free Chemical earthing of technology with copper bonded steel rod 3 mtr long 25.0 mm dia with 250-micron Copper bonded coating and UL listed. There should be terminal for connection of 150 x 50 x 6 mm with 4 holes of 12 mm dia along with 2 bags of 25 Kgs each of earth enhancing compound. The chemical compound should be tested and certified by any NABL accredited laboratory with 95 percent carbon content. The testing laboratory should be an ISO 9001 and 14001 certified. The earth enhancing compound should be IEC 62321. The ph value of compound should be 7-8. Electrode should be duly tested and certified by CPRI, Govt of India for a min short circuit current of 25 kA rms for 1 Sec. including necessary boring of suitable dia upto required depth in any type of soil for inserting copper rod and filling of chemicals and Poly plastic pit cover of material- polymer body & cover dimensions- 308 mm (L) x 308 mm (W) x 214 mm (H) bearing capacity 7.5 Ton approved from NABL approved Lab complete all as specified and as directed. Note:- (i) Earthing is to be done infront of the Engr-in-Charge.(ii) Test Results of earthing to be submitted by the contractor for all earthings.(iii) The Contractor shall have to give written guarantee for maintenance earth resistance of less than 1.0 Ohm for the period of 10 (ten) years after certified date of completion and shall bdeposited 2000/- per earthing as security deposit for a period of Ten (10) Years.(iv) Failing to maintain resistance of earthing less than 01.0 ohm , new earthing to be provided by the contractor with out any extra cost.(v) Necessary earth work, excavation shall be carried out in any type of soil strata, retuning, filling in and making good surronding area complete.
32M & L for GI earth strip continuity conductor fixed to wall /floor/drawn in holes /conduits or any situation as directed of size 32 x 6 mm including necessary GI Protection light grade pipe 40 mm dia and jointing strips with nuts bolts and brazing/welding at joints complete all as specified and as directed.
33M & L for Copper earth strip continuity conductor fixed to wall /floor/drawn in holes /conduits or any situation as directed of size 20 x 3 mm including necessary GI Protection light grade pipe 25 mm dia and jointing strips with nuts bolts and brazing/welding at joints complete all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57917906
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 84.62 Lakhs
LAST DATE 09-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provision Of Independent Feeder From Mseb At Site R At Af Station Thane
Basic Detail
Tender No 82769/E8
Bidding Type Tender
Location
City Thane
State Maharashtra
Key Dates
Publish Date 26 Oct 2026
Submission Date 09 Nov 2026
Open Date 16 Nov 2026
Finance
Tender Value 84.62 Lakhs
Tender Fee 1000
EMD 1.51 Lakhs
Exemption Available
Document List
82769PS.pdf
82769TD.pdf
b5785c7e-ac98-4d4e-8a6d-10767cb208db.html
BOQ_888951.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 26, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 09, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 11 days
Nov 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Nov 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
pdf

82769PS.pdf

pdf

82769TD.pdf

html

b5785c7e-ac98-4d4e-8a6d-10767cb208db.html

xls

BOQ_888951.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender