Tender For special Repair To Lt Ug Cable And Allied Works At Umarao Vihar Under Ge (N) Binnaguri
Tender Value
37.87 Lakhs
Estimated cost
Bid Submission
31 Oct 2026
22 days left
EMD
75740
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jalpaiguri → West Bengal
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repair To Lt Ug Cable And Allied Works At Umarao Vihar Under Ge (N) Binnaguri
BOQ
| Sl. No. | Item Description |
| 1 | Taking out old unserviceable cable of any size carefully from trenches ofter disconnecting electric connection, GI pipe protection, with and including separating serviceable bricks and removing un-serviceable bricks from site complete all as specified and as directed. Note : The Excavation and earth work shall be mesured and paid separately under relevant item of Schedule. |
| 2 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded,galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 25 sqmm 3 core with and including all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc and including taking down dismantling of old existing unserviceable one complete as specified and as directed. ( NOTE: Earthwork & Excavation, Gl pipe, bricks for protection etc shall be measured and paid separately under relevant items of this schedule 'A'). |
| 3 | All as per ser item No 2 above but of cross sectional area 50 sqmm 3 core |
| 4 | All as per ser item No 2 above but of cross sectional area 70 sqmm 3 core |
| 5 | All as per ser item No 2 above but of cross sectional area 95 sqmm 3 core |
| 6 | All as per ser item No 2 above but of cross sectional area 120 sqmm 3 core |
| 7 | All as per ser item No 2 above but of cross sectional area 150 sqmm 3 core |
| 8 | All as per ser item No 2 above but of cross sectional area 240 sqmm 3 core |
| 9 | All as per ser item No 2 above but of cross sectional area 300 sqmm 3 core |
| 10 | Digging out incoming and outgoing cables of any sizes from loops near junction box/ feeder pillar box in trenches, cutting burnt out uninsulated portion of cable and relaying /refixing in trenches & returning, refilling the excavated soil and connecting the cables with bus bars including provision of suitable size of aluminum lugs complete all as specified and as directed. |
| 11 | Relaying in trenches or passing through pipe, 1100 volts grade, LT electric power UG cables, of any type/Size with and including all fixing & connecting accessories such as Aluminum cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. Note : The serviceable cable obtained from taking out from item No 1 here-in-before shall be reused. |
| 12 | S&F moulded case circuit breaker (MCCB) four pole Adjustable type 415 volt, 50 Hz 63 to 100 Amps of breaking capacity 36 KA including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 13 | S&F moulded case circuit breaker (MCCB) four pole Adjustable type 415 volt, 50 Hz 125 to 160 Amps of breaking capacity 36 KA including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 14 | S&F moulded case circuit breaker (MCCB) four pole Adjustable type 415 volt, 50 Hz 160 to 200 Amps of breaking capacity 36 KA including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 15 | S&F moulded case circuit breaker (MCCB) four pole Adjustable type 415 volt, 50 Hz 200 to 250 Amps of breaking capacity 36 KA including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 16 | S&F moulded case circuit breaker (MCCB) four pole Adjustable type 415 volt, 50 Hz 250 to 320 Amps of breaking capacity 36 KA including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 17 | S&F moulded case circuit breaker (MCCB) four pole micro processor release type 415 volt, 50 Hz 630 Amps of breaking capacity 36 KA including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 18 | S&F MCB, Single pole & neutral, 32 to 63 amps, 240 volts, 'C' curve, 10KA including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 19 | M&L horizontal boring of holes, under road/ pavement / hard standing etc. in any type of soil, suitable for passing 50 mm bore, galvanised steel tubing complete all as specified and as directed.Notes :- (a) Rate quoted for GI Pipe light grade is deemed to be inclusive in the UNIT TATE QUOTED.(b) Removal of surplus soil shall be deemed to be included in the Unit Rate. |
| 20 | Dismantling of old unserviceable LT feeder pillar box/LT panel including PCC/Brick wks foundation after disconnecting of all electrical connection complete all as specified and as directed. |
| 21 | Supply, fabrication, installation, testing and commisioning in replacement of LT 3 Phase 4 wire 450 Volts system, factory made,CPRI Approved, water and vermin proof protection pedestal type feeder pilar box of minimum size 1600 mm x 1200 mm x 450 mm (overall) of out door type made out of 3.15 mm thick CRCA sheet with frame and legs of mild steel angle iron of size 40 x 40 x 6 mm in all side with double door, front and back side openable hinged door and air ventilation arrangement including . Danger notice plate with letters, figures and conventional skull and bones in signal red and shall be fixed on main door. The pannel shall be complete painted with Powder Coated paint of approved shade. \\"U\\" type gas ket shall be used to make the inner shell completely vermin proof to accomodate incommers/outgoing MCCBs. All interconnection between the main bus bar as well as out going feeders shall be carried out with TPN aluminim bus bar of rating not less than 1.5 times the rated capacity of individual out going feeders and should be insulated with heat shreank cable PVC shleaves and shall be mounted on suitable size \\"F\\" class insulators. The degree of protection of outer shell of the panel shall be IP-65. A detachable pre drilled gland plate should be used at bottom. All control wire shal be with 2.5 sqmm multi stranded copper conductors and shall be properly brunched, tied, ferruled for proper identification and print with adequate size of lugs complete with and including PCC (1:3:6) type C-2 of size 0.60 m x 0.45 m x 0.9 m depth (30 cm below ground level and 60 cm above ground level) as in foundation in cement mortar 1:6 and plastering the same in cement mortar 1 : 6 finished even and smooth with out using extra cement complete including necessaqry excavation, earth work and including connecting all incoming and outgoing LT UG cables after drawing/ digging out cable from loops in treanches complete all as specified and as directed along with and including the following accessories : - [Note : (i) Cost of earth work and PCC are deemed to be inclusive in the UNIT Rate quoted item (ii) the schematic diag of LT pannels shall be approved by GE before procurement. (a) Aluminum busbar 600 Amps capacity including insulator with nuts & bolts-04 Nos (b) Incomming : MCCB 4 pole, 415 volts, 36 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 250 amps including all fixing accessories with both ends spreader links .-01 Nos (c) Outgoing : MCCB 4 pole, 415 volts, 25 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 63 amps including all fixing accessories with both ends spreader links . -04 Nos(d) Neon indicator lamp with holder (RYB) = 03 Nos (e) Digital Voltmeter of range (0-500) volt flush mounting type with selector switch = 01 No (f) Digital Ammeter of range (0-400) Amp flush mounting type with selector switch = 01 No(g) Iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of FPB for LT -01 No |
| 22 | Supply, fabrication, installation, testing and commisioning in replacement of LT 3 Phase 4 wire 450 Volts system, factory made,CPRI Approved, water and vermin proof protection pedestal type feeder pilar box of minimum size 1000 mm x 800 mm x 350 mm (overall) of out door type made out of 3.15 mm thick CRCA sheet with frame and legs of mild steel angle iron of size 40 x 40 x 6 mm in all side with double door, front and back side openable hinged door and air ventilation arrangement including . Danger notice plate with letters, figures and conventional skull and bones in signal red and shall be fixed on main door. The pannel shall be complete painted with Powder Coated paint of approved shade. \\"U\\" type gas ket shall be used to make the inner shell completely vermin proof to accomodate incommers/outgoing MCCBs. All inter connection between the main bus bar as well as out going feeders shall be carried out with TPN aluminim bus bar of rating not less than 1.5 times the rated capacity of individual out going feeders and should be insulated with heat shreank cable PVC shleaves and shall be mounted on suitable size \\"F\\" class insulators. The degree of protection of outer shell of the panel shall be IP-65. A detachable pre drilled gland plate should be used at bottom. All control wire shal be with 2.5 sqmm multi stranded copper conductors and shall be properly brunched, tied, ferruled for proper identification and print with adequate size of lugs complete with and including PCC (1:3:6) type C-2 of size 1000mm x 450mm x 900mm depth (30 cm below ground level and 60 cm above ground level) as in foundation in cement mortar 1:6 and plastering the same in cement mortar 1 : 6 finished even and smooth with out using extra cement complete including necessaqry excavation, earth work and including connecting all incoming and outgoing LT UG cables after drawing/ digging out cable from loops in treanches complete all as specified and as directed along with and including the following accessories : - [Note : (i) Cost of earth work and PCC are deemed to be inclusive in the UNIT Rate quoted item (ii) the schematic diag of LT pannels shall be approved by GE before procurement. (a) Aluminum busbar 600 Amps capacity including insulator with nuts & bolts-04 Nos (b) Incomming : MCCB 4 pole, 415 volts, 36 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 400 amps including all fixing accessories with both ends spreader links .-01 Nos (c) Outgoing : MCCB 4 pole, 415 volts, 25 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 63 amps including all fixing accessories with both ends spreader links . -06 Nos(d) Neon indicator lamp with holder (RYB) = 03 Nos (e) Digital Voltmeter of range (0-500) volt flush mounting type with selector switch = 01 No (f) Digital Ammeter of range (0-400) Amp flush mounting type with selector switch = 01 No(g) Iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of FPB for LT -01 No |
| 23 | Supply, fabrication, installation, testing and commisioning in replacement of LT 3 Phase 4 wire 450 Volts system, factory made,CPRI Approved, water and vermin proof protection pedestal type feeder pilar box of minimum size 1000 mm x 800 mm x 350 mm (overall) of out door type made out of 3.15 mm thick CRCA sheet with frame and legs of mild steel angle iron of size 40 x 40 x 6 mm in all side with double door, front and back side openable hinged door and air ventilation arrangement including . Danger notice plate with letters, figures and conventional skull and bones in signal red and shall be fixed on main door. The pannel shall be complete painted with Powder Coated paint of approved shade. \\"U\\" type gas ket shall be used to make the inner shell completely vermin proof to accomodate incommers/outgoing MCCBs. All inter connection between the main bus bar as well as out going feeders shall be carried out with TPN aluminim bus bar of rating not less than 1.5 times the rated capacity of individual out going feeders and should be insulated with heat shreank cable PVC shleaves and shall be mounted on suitable size \\"F\\" class insulators. The degree of protection of outer shell of the panel shall be IP-65. A detachable pre drilled gland plate should be used at bottom. All control wire shal be with 2.5 sqmm multi stranded copper conductors and shall be properly brunched, tied, ferruled for proper identification and print with adequate size of lugs complete with and including PCC (1:3:6) type C-2 of size 1000mm x 450mm x 900mm depth (30 cm below ground level and 60 cm above ground level) as in foundation in cement mortar 1:6 and plastering the same in cement mortar 1 : 6 finished even and smooth with out using extra cement complete including necessaqry excavation, earth work and including connecting all incoming and outgoing LT UG cables after drawing/ digging out cable from loops in treanches complete all as specified and as directed along with and including the following accessories : - [Note : (i) Cost of earth work and PCC are deemed to be inclusive in the UNIT Rate quoted item (ii) the schematic diag of LT pannels shall be approved by GE before procurement. (a) Aluminum busbar 600 Amps capacity including insulator with nuts & bolts-04 Nos (b) Incomming : MCCB 4 pole, 415 volts, 36 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 100 amps including all fixing accessories with both ends spreader links .-01 Nos (c) Outgoing :Aluminum busbar 600 Amps capacity including insulator with nuts & bolts-04 Nos (d) Iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of FPB for LT -01 No |
| 24 | M&L preparation of the old decorated existing external steel surface of feeder pillar boxes/LT panels of any size and description in any position including removal of disintegrated & deteriorated paint either by hand scrapping or by blow lamps, applying necessary filler coat and stopping required and applying two coats of synthetic enamel paint by using spray painting machine on old prepared surface including marking of Sub Stn No, Feeder No and feeding area/Bldg with applying synthetic enamel paint (1st grade) complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 25 | M&L preparation of the old decorated existing external steel surface of feeder pillar boxes/LT panels of any size and description in any position including removal of disintegrated & deteriorated paint either by hand scrapping or by blow lamps, applying necessary filler coat and stopping required and applying two coats of synthetic enamel paint by using spray painting machine on old prepared surface including marking of Sub Stn No, Feeder No and feeding area/Bldg with applying synthetic enamel paint (1st grade) complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 31, 2026
17:00 IST