Tender For Development & Renovation Of Chc Komna (Ama Hospital Phase Ii) In The District Of Nuapada For The Year 2026-27.

Issued by Government Departments · Nuapada, Odisha
Tender Value
3.12 Crore
Estimated cost
Bid Submission
22 Oct 2026
7 days left
EMD
3.13 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nuapada → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Development & Renovation Of Chc Komna (Ama Hospital Phase Ii) In The District Of Nuapada For The Year 2026-27.

BOQ

Name of Work:- DEVELOPMENT & RENOVATION OF CHC KOMNA (AMA HOSPITAL PHASE II) IN THE DISTRICT OF NUAPADA FOR THE YEAR 2026-27.
Sl. No. Item Description
1CIVIL PORTION OF THE WORK:- Earthwork in excavation in all types of soil for site leveling, foundation, pits, trenches and other civil works upto and including 1.5 metre depth and stacking the soil upto a lead of 100 metre and including dewatering, removing slush,shoring and strutting (as required), complete as per specification and as directed by the Engineer-In-Charge.
2Supplying and filling sand in foundation and over areas including watering, ramming, consolidating and dressing, labours, tools, taxes etc. all complete as per the specification and direction of Engineer-In-charge.
3Providing and lying plain cement concrete of proportion (1:3:6) in foundation and floors using Portland slag cement (PSC) with 40 mm. Size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm thick in each layer including cost, conveyance, loading, unloading, royalties and taxes all materials and cost all labours, sundries, T & P required for the work including shoring, shuttering and dewatering if required including hire & running charges of water pump complete as per the instruction of the Engineer-in-Charge.
4R.C.C. work of M-20 in following works using 12 mm. to 20 mm. (%\\" to %\\") size (20 mm. not to exceed 25%) hard black crusher broken granite stone chips of approved quality from approved quarry including hoisting, lowering, laying and compacting concrete, watering curing, centering, shuttering and finishing the exposed surfaces smooth with cost, conveyance, royalties, taxes of all materials with all labour,labour cess and T & P required for the work etc. complete in all respect but excluding the cost and conveyance of M.S. rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position and as per the direction of the Engineer in-charge. For Column BaseGround Floor
5Column / BeamGround Floor
6Plinth Beam
7Lintel Ground Floor
8Chajja ( Avg. 2.5\\" thick)Ground Floor
9Roof SlabGround Floor
10Roof BeamGround Floor
11DrainBed concrete
12Side wall
13Cover slab
14Plain cement concrete (1:2:4) using 12mm size black hard crusher broken granite chips of approved quality from approved quarry including hoisting, lowering and laying concrete in layers, watering, curing etc. complete including cost, conveyance, royalties and taxes of all materials with labour,labour cess and T&P etc. required for the work complete as per the direction of the Engineer-in-charge.
15Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / Tiscon / RINL / JINDAL STEEL / SHYAM STEEL (grade Fe-500D) etc. including bending, binding, welding and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances, taxes of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge.Ground Floor
16Fly ash brick masonry in cement mortar (1:6) using 23 Cm. x 11 Cm. x 8 Cm. size fly ash bricks having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance + 2 % in foundation and plinth including cost, conveyance, royalty, loading, unloading of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-Charge. Foundation and Plinth
17Fly ash brick masonry in cement mortar (1:6) using 23 Cm. x 11 Cm. x 8 Cm. size fly ash bricks having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance + 2 % in Superstructure including cost, conveyance, royalty, loading, unloading of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-Charge.Ground Floor
18Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joint, including watering and curing, rounding of cormers, providing grooves where ever necessary with cost, conveyance, royalties and taxes of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. Ground Floor
19Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ev r necessary with cost, conveyance, royalties and taxes of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. Ground Floor
206 mm thick cement plaster (1:4) to R CC surfaces finished smooth including closed deep chiping and slury treatment. in Ground FloorGround Floor
21Finishing surface of walls with cement based wall putty (water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials labour T & P etc. as per direction of Engineer -In -charge. in Ground FloorGround Floor
22Supplying, fitting & fixing of Vitrified floor tiles of premium grade having thickness 8mm to 10mm confirming to IS 13755 of sizes. 60cm x 60cm coloured/printed series laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge (for New Work only )Ground Floor
23Supplying, fitting & fixing of Vitrified floor tiles of premium grade having thickness 8mm to 10mm confirming to IS 13755 of sizes. 60cm x 60cm coloured/printed series laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge. Ground Floor
24Supplying, fitting & fixing of CeramicTiles of minimum 16mm thick and above 0.10 sqm of approved make in floors over 25mm thick bed of cement mortar 1:1 jointed with cement slurry mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance, taxes & royalties of all materials, labour with T&P complete in all respect.(Data for 10 Sqm )Ground Floor
25Supplying, fitting & fixing of 30cm x 30cm/40cm x 40cm special plain/printed series Ceramic floor tiles of premium grade having thickness 7mm to 8mm confirming to IS 13755 in floors laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with slurry including cost of all materials, labour T&P etc. required for the work all complete incl. rubbing as per direction of the Engineer-in-chargeGround Floor
26Supplying, fitting & fixing of Granite Tiles of minimum Above 0.40 sqm. (20mm thick) of approved make in floors laid on 20 mm thick cement mortar (1:3) (1 cement : 3 course sand) and filling joints with slurry including cost of all materials, labour T&P etc. required for the work all complete incl. rubbing as per direction of the Engineer-in-chargeGround Floor
27Supplying, fitting & fixing of Kota Tiles of minimum 16mm thick and above 0.10 sqm of approved make in floors over 25mm thick bed of cement mortar 1:1 jointed with cement slurry mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance, taxes & royalties of all materials, labour with T&P complete in all respect.(Data for 10 Sqm )Ground Floor
28Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar/ flat including stair case hand railing with 40mm. dia G.I.pipe etc. including painting two coats coat of redoxide primer as per approved drawing and design with cost of all materials & labour, taxes, labour cess, T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-Charge. All FloorSupplying ,fitting and fixing of ISMB Sections for cow catcher (16.8m x 1.5m) including labour for lifting,hoisting and placing in position to required size and length ,pre fabricating by cutting to sizes,priming including cost of all materials,cost of all labour,loading,unloading at site,all accessories,T&P required for the work complete in all respect as directed by Engineer in Charge.Providing ,Supplying & Fixing of 80mm dia heavy gauge G.I. Pipe(Jindal brand steel) for cow catcher (16.8mX1.5m) including labour for lifting,and placing in position to required length,pre fabricating by cutting to required length,priming including cost of all materials, cost of all labour,loading,unloading at site ,all accessories,T&P required for the work complete in all respect as directed by Engineer in Charge.Supplying ,fitting and fixing of 25x6 MS Flat including labour for lifting and placing in position to required length, pre fabricating by cutting to require length ,priming including cost of all materials,cost of all labour,loading,unloading at site,all accessories,T&P required for the work complete in all respect as directed by Engineer in Charge.
29Earth work in excavation of foundation in hard soil including dewatering , shoring and shuttering etc..Toewall
30C.C. (1:3:6) with 4cm size metal in Leveling course including dewatering .Toewall
31Filling foundation and plinth with excavated earth.
32Wall Painting two coats with approved Plastic Emulsion Paint in Ground FloorGround Floor
33First Floor
34Second Floor
35Painting two coats with any approved colour of weather seal coat to out side surface of wall in Ground FloorGround Floor
36First Floor
37Second Floor
38Priming one coat with approved Water Bound Wall cement Primer on Plastered Surface including all cost etc complete.Ground Floor
39Painting two coats with Synthetic enamel paint over a coat of primer to new wood works including cost, conveyace of all materials and labour (T&P) etc. complete as per the direction of Engineer-in-Charge.Ground Floor
40Dismantling and removing old tiled flooring including stacking the useful materials for reuse and removing the debris within 50m lead.
41Dismantling brick or stone masonry in lime or cement mortar under 3mtr height including stacking the useful materials for reuse and removing the debris within 50m lead.
42Construction of embankment with approved materials obtained from borrow pits with all lifts and leads transportating to site within a lead of 5km and spreading grading to required slope and compacting to meet reqirement of table 300-2 and Clause-305 of MoRT&H specifications for Road & Bridge Works.
43Providing fitting fixing of false ceiling with Aluminium anodised T section No.3215 with 2'0\\" center to center, L section No.1705 on 4 walls to be fixed by means of steel screw and P.V.C. plug and the Aluminium grid 2'0\\"x2'0\\" with water proof Gypsum board suspended from ceiling including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-charge
44C.C. (1:4:8) using 4cm size b.h.g.c.b. metal including watering, curing with cost, conveyance, royalty and taxes of all materials and labour etc. complete.
45C.C. (1:2:4) using 12mm size b.h.g.c.b. chips including watering, curing with cost, conveyance, royalty and taxes of all materials and labour etc. complete.
46Supplying and fixing of Pre cast kerb stone of size 600mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984.
47Supplying and fixing Colour G.C.I sheet on roof with all cost of materials, labour, carriage etc complete .
48Providing fitting and fixing up partition walling OEL aluminium anodised section No-9210 and 9207 as single groove and double groove respectively as horizontal and vertical member and OEL section 4660 as tapered clip for fixing up 12 mm thick prelaminated board and jointing angle No-1855 etc Data for 6'-10\\" x 7'-6\\" = 51.22sft or 4.76 sqm=24.39 KgGround floor
4912 mm thich Prelaminated particle boardGround floor
506mm thick plain glassGround floor
51Supplying Fitting, fixing Two Track UPVC Sliding framed window of approved make with 6mm thick glass of approved quality complete with frame shutters and all fitting and fixtures complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge
52Supplying Fitting, and fixing of openable UPVC Doors with Door frame of approved make with 6mm thick glass of approved quality complete with frame shutters and all fitting and fixtures complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge
532.5 cm thick grading concrete (1:2:2) on roof slab with 6.7mm & down grades size hard granite crusher broken chips on new work
54Providing, fitting and fixing of Al door with anodized Al. door section of 9202 as vertical member, 9201 as top and 9200 as middle and bottom member with frame section No.9221 and tapered clip no. 4660 and the frame to be completed by means of jointing angle no. 1855 including all cost of labour, T&P, hire charges of drilling machine, labour charges , etc. complete as per direction of the Engineer-in-charge
55Supplying, fitting afixing of stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc. with cost conveyance, taxes of all materials labour, T&P etc. required for the complete as per the direction of Engineer-in-Charge.
56Internal E.I.Works:-Parking Shed,Main Gate,Security Room,Main Store,KMC Room & Ramp Area:-Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked, Make- Finolex/Anchor/Polycab/ HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/ Anchor/Kinjal and with 6A modular type ( flame retardant type) switch ISI marked, Make-Schneider(Zencelo)/legrand( Myrius)/ Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retardant type) Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) of suitable size, modular box with 1.5 sq. mm FRLS PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. All the switches & sockets should be warranted for a replacement period of 2 years against defects with ncessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.GROUP-A
57GROUP-B
58GROUP-C
59Supplying,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type & other required accessories of ISI marked as approved as per direction of Engineer-in-Charge. Make of Schneider(Zencelo)/ legrand( Myrius)/Panasonic (vision) (Maximum 02 nos point in one circuit).All the switches & sockets should be warranted for a replacement period of 2 years against defects with ncessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.
60Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type) with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of Engineer-in-charge.Make-Schneider(Zencelo)/ legrand( Myrius)/ Panasonic (vision).(Maximum 02 nos point in one circuit).All the switches & sockets should be warranted for a period of 2 years against manufacturing defects against which ncessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.
61Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket (modular type with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of Engineer-in-charge. Make-Schneider(Zencelo)/legrand(Myrius)/ Panasonic (vision) (For equipment power) All the switches & sockets should be warranted for a replacement period of 2 years against defects with ncessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.
62Supplying,fixing of 2x6A+1X16A Plug on the separate board with complete fitting by 2 nos of 6A + 1 no of 16A switch & socket(modular type) with suitable size modular box & metallic cover plate (both side) including supplying of all required accessories of ISI marked as approved as per direction of Engineer-in-charge.Make-Schneider(Zencelo)/ legrand (Myrius)/ Panasonic (vision) (For equipment power) (Maximum 02 nos point in one circuit).All the switches & sockets should be warranted for a replacement period of 2 years against defects with ncessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.
63Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/ Polycab/HAVELLS/ RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size, Make-AKG/BEC/Precision/ Norpak/Anchor/ Kinjal as required as per direction of Engineer-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 1 no of single core 1.5 sq. mm copper wire for earth continuity conductor in 20 mm dia non metallic heavy duty conduit (LSB to Light & Fan Points/LIGHT CKT) (2X1.5 +1X1.5)
64Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable, Make- Finolex/Anchor/ Polycab/HAVELLS/ RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/ Norpak/Anchor/ Kinjal as required as per direction of Engineer-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 1 no of single core 1.5 sq. mm copper wire for earth continuity conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/6A PLUG/ UPS POINT ) (2X2.5+1X1.5)
65Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable, Make- Finolex/Anchor/ Polycab/HAVELLS/ RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/ Norpak/Anchor/ Kinjal as required as per direction of Engineer-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 1 no of single core 1.5 sq.mm copper wire for earth continuity conductor in 20 mm dia non metallic heavy duty conduit.(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5)
66Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of POLYCAB/KEI/HAVELLS/GLOSTER,make, ISI marked with all other related materials as per direction of Engineer-in-Charge. Ncessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials (From MCB DB to Light Points at Vehicle Parking Shed)
67S/F of Bakelite angle holder/batten holder (make-Anchor/ Havells or equivalant reputed make A catagory ISI marked as approved) of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engineer-in-Charge.All the Components should be warranted for a replacement period of 2 years against defects with ncessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.
68S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer-in-charge. (Make-Schneider(Zencelo)/ legrand( Myrius)/ Panasonic (vision)
69Supplying & Installation of Exhaust fan of heavy duty 300 mm sweep 1400 rpm with metal body type (Make- Havells/Usha/ Crompton/Orient/Bajaj) Exhaust fan in the existing wall, including fixing & connection as required as per direction of Engineer-in-Charge. Replacement Warranty will be 2 years.
70Supplying, Installation, Testing and Commissioning of 1200 mm sweep white/milky colour BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min, Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix/Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engineer-in-Charge, Replacement Warranty will be 4 years.
71Supplying and fixing of Energy efficient surface/recess mounted square/round shape 18 W LED luminaire consisting of white powder coated, die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV, L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V A.C.supply as required as per direction of Engineer-in-Charge. (Make: Panasonic/LT/Havells/ Philips/Wipro/Crompton/ Bajaj). The luminaire should be Replacement Warranty for 2 years.
72SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc. as required as per direction of Engineer-in-Charge. (Make: Panasonic/ LT/ Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty for 2 years .
73Supplying & Fixing of 20watt LED Mini Flood Light (CDL Flood Light) Outdoor Lamp Cool white, Water proof set of Bajaj/Philips/Havells make.(For Parking Area lighting)
74S/F of 9 Watt LED Bulb of Philips/Bajaj/Havells make.
75S/F of decorative outdoor water proof IP54 Gate Light with 30Watt LED Lamp of Bajaj/Havells/Phillips make.
76Supplying and laying of one number PVC insulated armoured and PVC sheathed XLPE AL. conductor power cable of 1.1 KV grade,ISI marked of POLYCAB/KEI/HAVELLS /GLOSTER MAKE of following size cables as per direction of Engineer-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials3.5core x 50 sq.mm Aluminium Armoured Cable (From Main Panel to 100 Amp TPN Busbar at backside wall near exit door)
774 core x 16 sq. mm Aluminium Armoured Cable (From 100Amp TPN Busbar located at backside wall near exit door to Vehicle Parking Shed) 4 core x 16 sq. mm Aluminium Armoured Cable (From 100Amp TPN Main Switch at BMW Room to Water Pump)
782 core x 16 sq. mm Aluminium Armoured Cable (From 63Amp ICTPN Main Switch at Vehicle Parking Shed to 32Amp ICDP Main Switch at Security Room)
793.5core x 35 sq. mm Aluminium Armoured Cable (From 100Amp TPN Busbar located at backside wall near exit door to BMW Room)
803.5core x 25 sq. mm Aluminium Armoured Cable (From 100Amp TPN Busbar located at backside wall near exit door to Lawn area Outdoor Panel & Main Store)
81Laying of PVC Insulated PVC Seathed /XLPE power cable of 1.1 KV grade size above 25 Sq.mm and not exceeding 120 Sq.mm direct in ground in the trench in one horizontal formation including excavation,sand cushing, protection covering and refilling the trench etc. as required as per direction of Engineer-in-charge.(For 35 Sq.mm Cable)
82Laying of PVC Insulated PVC Seathed/XLPE power cable of 1.1 KV grade size upto 25 sq.mm and not exceeding 25 Sq.mm in surface with Shaddle and Screw etc. as required as per direction of Engineer-in-charge.(For 25 Sq mm Cable)
83Supply & Fixing of 100 amp TPN Copper Busbar with suitable enclosure box of an approved ISI Make ( L&T/ Havells/Anchor). (To be installed at backside wall near exit door)
84Supply & Fixing of 100 amp ICTPN Main switch of an approved ISI Make. ( L&T/ Havells/Anchor) (For BMW Room)
85Supply & Fixing of 32 amp ICDP Main switch of an approved ISI Make ( L&T/ Havells/Anchor)(For Security Room)
86Supply & Fixing of 63 amp ICTPN Main switch of an approved ISI Make ( L&T/ Havells/Anchor)(For Main Store & Vehicle Parking Shed)
87Supplying and fixing of 6 Way Double Door MCB Distribution Box Horizontal Type as per IEC 61439-3 with configuration of incoming 2 modules & out going-4 modules,suitable for Flush mounting and Surface mounting with metal door. Warranty on DB is 3 years. (For Vehicle Parking Shed & Security Room)
88Supplying and fixing 25 Amps rating,C series,10KA breaking capacity, DP, 240 volts, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB FB200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engineer.-in-Charge. The RCCB should be Replacement Warranty for 1 year.(For Vehicle Parking Shed & Security Room)
89Supplying and fixing 6 amps to 32 amps rating, 240 volts, C' series,10KA breaking capacity, single pole MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200. the existing MCB DB complete with all connections as per direction of Engineer-in-Charge. Warranty on MCB is 1 year.(For Vehicle Parking Shed & Security Room)
90Supplying and fixing of 4-Way (4 +12) Double door TPN MCB disribution box Horizontal Type as per IEC 61439-3 with configuration of incoming 4 modules & out going-12 modules, suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years.(Main Store)
91Supplying and fixing 40 Amps rating, C series,10KA breaking capacity,4P, 415 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty for 1 year.(Main Store)
92Supplying and fixing 32 Amps rating,C series,10KA breaking capacity, DP, 240 volts, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB FB200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. The RCCB should be Replacement Warranty for 1 year.(Main Store)
93Supplying and fixing 6 amps to 32 amps rating, 240 volts, C' series,10KA breaking capacity, single pole MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200. the existing MCB DB complete with all connections as per direction of Engg.-in-Charge. Warranty on MCB is 1 year.(Main Store)
94S/F of Standard Earthing with G.I. earth pipe of 3mtr.Long 40mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required.
95Supply & Laying of SWG No.8 G.I. Earth Wire of any ISI make for laying to maintain earth continuity.
96Conference HallRecessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked, Make- Finolex/Anchor/Polycab/ HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/ Anchor/Kinjal and with 6A modular type ( flame retardant type) switch ISI marked, Make-Schneider(Zencelo)/legrand( Myrius)/ Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retardant type) Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) of suitable size, modular box with 1.5 sq. mm FRLS PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. All the switches & sockets should be warranted for a replacement period of 2 years against defects with ncessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.GROUP-B
97GROUP-C
98Supplying,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type & other required accessories of ISI marked as approved as per direction of Engineer-in-Charge. Make of Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (Maximum 02 nos point in one circuit).All the switches & sockets should be warranted for a replacement period of 2 years against defects with ncessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.
99Supplying,fixing of 1x25A Plug on the separate board with complete fitting by 01 no of 25A switch & 25A socket (modular type with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of Engineer-in-charge. Make-Schneider(Zencelo)/ legrand(Myrius)/ Panasonic (vision) (For equipment power) All the switches & sockets should be warranted for a replacement period of 2 years against defects with ncessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.
100Supplying and fixing of Energy efficient surface/recess mounted square/round shape 18 W LED luminaire consisting of white powder coated, die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV, L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V A.C.supply as required as per direction of Engineer-in-Charge. (Make: Panasonic/LT/Havells/ Philips/Wipro/Crompton/ Bajaj).The luminaire should be Replacement Warranty for 2 years.
101Supplying and fixing of 4-Way (4 +12) Double door TPN MCB disribution box Horizontal Type as per IEC 61439-3 with configuration of incoming 4 modules & out going-12 modules, suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years.
102Supplying and fixing 63 Amps rating, C series,10KA breaking capacity,4P, 415 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engineer-in-Charge. The MCB should be Replacement Warranty for 1 year.
103Supplying and fixing 40 Amps rating,C series,10KA breaking capacity, DP, 240 volts, MCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB FB200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engineer-in-Charge. The RCCB should be Replacement Warranty for 1 year.
104Supplying and fixing 6 amps to 32 amps rating, 240 volts, C' series,10KA breaking capacity, single pole MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200. the existing MCB DB complete with all connections as per direction of Engineer-in-Charge. Warranty on MCB is 1 year.
105Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/ Polycab/HAVELLS/ RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size, Make-AKG/BEC/ Precision/ Norpak/Anchor/ Kinjal as required as per direction of Engineer-in-Charge. 2 nos single core 6 sq. mm copper wire for phase and neutral and 1 no of single core 2.5 sq. mm copper wire for earth continuity conductor in 25 mm dia non metallic heavy duty conduit (MCB DB to A.C Points) (2X6+1X2.5)
106Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/ Polycab/HAVELLS/ RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size, Make-AKG/BEC/ Precision/ Norpak/Anchor/ Kinjal as required as per direction of Engineer-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 1 no of single core 1.5 sq. mm copper wire for earth continuity conductor in 20 mm dia non metallic heavy duty conduit (LSB to Ceiling Light Points/LIGHT CKT) (2X1.5 +1X1.5)
107Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable, Make- Finolex/Anchor/ Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/ Norpak/Anchor/Kinjal as required as per direction of Engineer-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 1 no of single core 1.5 sq. mm copper wire for earth continuity conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/6A PLUG/ UPS POINT) (2X2.5+1X1.5)
108Supplying and laying of one number PVC insulated armoured and PVC sheathed XLPE AL. conductor power cable of 1.1 KV grade,ISI marked of POLYCAB/KEI/HAVELLS/ GLOSTER MAKE of following size cables as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials3.5core x 25 sq. mm Aluminium Armoured Cable (From 100Amp TPN Busbar at backside near exit door to TPN DB of Conference room)
109Laying of PVC Insulated PVC Seathed/XLPE power cable of 1.1 KV grade size upto 25 sq.mm and not exceeding 25 Sq.mm in surface with Shaddle and Screw etc. as required as per direction of Engineer-in-charge. (For 25 Sq mm Cable)
110SPLIT AC2 TR high wall 5 star inverter type split A.C machine (BTU/Hr-18000)with copper condensor & evaporator having ambient temperature 52 degree celcius with comprehensive 1 year warranty,5 years warranty on PCB, 5 years warranty on compressor (Make:O-General/Diakin/Mitsubishi/Hitachi/equivalent) (For Conference Hall)
111REFRIGRANT PIPINGSupply,installation of hard/soft copper refregrant piping of size 5/8 inch and 1/4 inch for suction and liquid line with 3 corex4 sqmm FRLS Copper control cable alongwith 25 mm weather proof closed cell nitrile insulation ,complete with fitting of bends and other nesessary material to complete the job.1 TR to 3 TR high wall split A.C
112FRAME WORKSupply,installation & fabrication of MS base frame for both indoor and outdoor unit and other nesessary material to complete the job.1 TR to 3 TR high wall split A.C
113DRAIN PIPINGSupply,installation & fabrication of Insulated drain water piping from indoor to nearest drain point separate to all and other nesessary material to complete the job.25mm nom. Dia pipe
114CONTROL CABLESupply,laying of control cable and other nesessary material to complete the job.For 1 TR to3 TR high wall split A.C
115Supply and fixing of 5kVA Voltage stabilizer (Make-V-Guard/ Microtek)
116S/F of 32Amp AC starter switch Havells/ legrand /or equivalent make.
117Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers in 40mm dia G.I.Pipe of 3 mtr. length inside ground including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and refilling as usual as per direction of Engineer-in-charge.
118Providing and fixing 25mm x 5 mm GI strip laying from G.I.plate to upwards on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
119Supply & Laying of SWG No.8 G.I. Earth Wire of any ISI make for laying to maintain earth continuity.
120Lightning Protection System:-Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB
121Supply of Roof conductor holder for parapet- PolyamideConductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather andtemperature resistant from -35 to +90 degree Celsius tested.Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB.
122Supply of Polyamide roof cable holder for flat roof:DIN 48829 Form B1. Closed form with bottom. Filling weight1Kg (frost-resistant concrete). Sleeve from polyethylene, black@ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn/ABB
123Supply of Connector: For T cross and parallel connectors. Quickinstallation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn/ABB
124Supply of 1 mtr vertical air terminal with mounting accessorieson the flat surface to meet the requirements of IS/IEC 62305.Tested for Electrical , mechanical and chemical as per IEC62561. Tested for 100kA lightning current. Make-OBO/Dehn/ ABB
125Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm aluminium rod: 2 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load.Tested as per IEC 62561. Make-OBO/Dehn/ABB
126Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . Make-OBO/Dehn/ABB
127Supply for Providing of Stand for Fang Fix system 16 kg made up of frost resistant concrete. Make-OBO/Dehn/ABB
128Supply of Test Joint (Folding Clamp) suitable to connect 8mmround conductor and max by 30x3 mm GI strip as specified indrawing and directed by Engineer-in-charge.Tested for 100kA lightning current. Make-OBO/Dehn/ABB
129Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr Height.For Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn/ABB
130Supply of Galvanised Steel Flat 30X3 mm thickness from earthelectrode directly in ground as required. Flat conductor HotDipped Galvanized. Tested as per IEC 62561. Make-OBO/ Dehn/ABB
131Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/ ABB
132Supply of flat conductor holder- Fit: FL 30, With mounting hole6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black.Tested as per IEC 62561. Make-OBO/Dehn/ABB
133Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/ABB
134Supply of UL Listed maintenance free ,Low carbon coppercoated earth rod of 3 metre electrode having diameter of 17.2mm with copper coating thickness of 250micron tested as perIEC 62561-2 Make-OBO/Dehn/ABB
135Supply of universal clamp made of SS to connect rod with flatconductor Make-OBO/Dehn/ABB
136Supply of Earth conductivity enhancing mineral compound shall be of 25kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn/ABB
137Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system Make-OBO/Dehn/ABB
138Installation of the above arrangements including all accessories as per direction of Engineer-in-charge.
139Servo stabilizerSupply,Installation,Testing & Commissioning of 250KVA (200KW) Servo Control Voltage Stabilizer (SCVS) having Specification & Special Features such as 3-phase In & 3-phase Out,Independent phase voltage controller,Under voltage/Over voltage protection,Alarm & Cut off at Output volts,Overload and Short Circuit protection,Auto-Manual Operation,Voltage limit indicator,Output Voltage adjustable, Input/Output voltage monitoring,Oil Cooled,Input Voltage Range:-300-480Volts.Output Voltage:-400VAC +/ -3%, Frequency-50 Hz +/- 3 Hz,Response time-1 milli second,Rate of Correction-105V/Sec, Efficiency Better than 98% and 100% Continuous Duty Cycle etc.(Make of APS/SM-VOLTSMART/ Servomax/Microtek)
140250KVA Servodistribution set up with installation of 500A Changeover switch with rotary switch with enclosure box -1no, 500A Busbar FP-1 Set,Earth wire -15mtr including all required secondary accessories as per direction of engineer in charge (switch gear make L&T/Legrand/Havells/equivalent)
141Supply of 3&1/2 Core 300sq.mm PVC Alluminium Armoured Cable of Havells/Polycab/KEI/Gloster make.
142Laying of PVC Insulated PVC Seathed/XLPE power cable of 1.1 KV grade size not exceeding 400 Sq.mm from 120 Sq.mm in surface with Shaddle and Screw etc. as required as per direction of Engineer-in-charge.(For 300 Sq.mm Cable)
143INTERCOM SYSTEM:-IP-PBXSupply, Installation,Testing & Commisioning of Grand Stream UCM-6302, IP PBX System support upto 1000Users and minimum 60 concurrent calls, integrated 2 PSTN trunk FXO ports through External Gateway, 2 analog telephone FXS ports with lifeline capability and up to 50 SIP trunk accounts, Gigabit network ports with Integrates PoE, USB, SD card, Supports up to a 5-level IVR (Interactive Voice Response), Supports any SIP video endpoint that uses the H.264, H.263 or H.263+ codecs.Make: Grandstream/Panasonic/Beetel
144Supply, Installation,Testing & Commisioning of IP based PoE Phone with single lie Displaywith 2 Ethernet Port. Make: Grandstream/ Panasonic/ Beetel
145Complete Installation charges with all required materials to complete job.
146Cable:-Supply,Installation,Testing & Commissioning of 4 pair Cat-6U/UTP Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Tyco/ Legrand/ Panduit
147ConduitsSupply, delivery and laying of following sizes of 2mm thick PVC Conduit concealed in wall/ column/ roof slab of the building alongwith other accessories and 18 swg GI wire complete for Electrical Wiring/Telephone / TV & Data cable wiring as required and as per direction of Engineer-in-charge. (Make:- NORPACK/ AKG/ BEC/ PRECISION)20mm dia
14825mm dia
149Indoor LED monitor Provision of samsung crystal 65AU7700,65inch ULTRA HD smart LED 4K TV/Vertical mount display of equivalent make supports are solution of 4K,3840 x2160 pixels has a refresh rate of 60Hz and an aspect ratio of 16:9 video format support on the TV . The port availability includes 2 x USb 2.0ports 3xHDMI port x VGA Input port and one digital audio output port wireless connectivity involves wifi and blue tooth 5.0 with set up box & sound sytem arrangements of make Bosch/ sony /JBL/ samsung etc. complete with all accessories as per direction of engineer in charge.
150Outdoor LED WallOutdoor LED Wall Provision of high class P6 outdoor SMD RGB Module(192 x192) MM Driving Ic-5M/ICN Brand:quangli/Unilumin as per direction of engineer in charge.
151Provision of Sending card/Processor model A4Brand Huidu as per direction of engineer in charge.
152Provision of power supply SmPS 60A 5V Brand Rong Elecric as per direction of engineer in charge.
153Provision of power supply SmPS40A 5V Brand Rong Elecric as per direction of engineer in charge.
154Provision of QMS backend server software with database as per direction of engineer in charge.
155Provision of Outdoor MS iron cabinet size 960 x 960 MM make as per direction of engineer in charge.
156Provision of Monopole as per direction of engineer in charge.
157Provision of Outdoor Iron structure per direction of engineer in charge.
158Provision of ACP Board only shed as per direction of engineer in charge.
159Provision of charges for transportation & wiring as per direction of engineer in charge.
160Provision of Installation,testing ,power supply with cable,& commissioning charges as per direction of engineer in charge.
161Provision of Receiving Card Modl No R-512/R508 Brand Huidu as per direction of engineer in charge.
162S/F of mounting structure for Outdoor led wall base structure, Channel frame, background structure complete with all accessories
163Campus Lighting:-Supply of 9 mtr long hot dip galvanized Octagonal pole with channel bracket (for mounting at least 8 nos. of flood light) manufactured from HT steel having base dia of 210 mm & top dia 90 mm or more and sheet thickness of 4 mm or more and 4 Nos. M30X850mm EN8 Grade foundation bolt. The octagonal pole shall be suitable to withstand 200 KM/Hour or more wind speed by considering the weight & wind expose area . All accessories included like anchor plate, foundation nuts & bolts including required size of control cable from starter panel to each light. Make:- Bajaj/RR Ispat/Utkarsh / Vakrangee/Valmont.
164Supply,Installation,Testing & Commissioning of 250 watt LED Flood Light with CCT 6000/5700/3000K Luminaire with efficiency more than 120 Lumens/watt and indivisual LED with secondary optics made in high pressure die-cast housing with toughned glass and heat sink in Aluminium extrusion with IP 66 protection complete of Havells/Panasonic/Bajaj/ Phillips/ Crompton/LT make.(5 years warranty)
165Supply & fixing of Decorative Round Arm bracket with all accessories suitable for fixing of 8 Nos Flood light fittings including Clamp & Nut Bolts.
166Supplying and laying of one number PVC insulated armoured and PVC sheathed XLPE AL. conductor power cable of 1.1 KV grade,ISI marked of POLYCAB/KEI/HAVELLS MAKE of following size cables as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials4core x 6 sq mm
167Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of POLYCAB/KEI/HAVELLS/GLOSTER,make, ISI marked with all other related materials as per direction of Engineer-in-Charge. Ncessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials (For connection from Junction box to light)
168Supply & Fixing of Standard Earthing with G.I Earth pipe 3 Mtr. Long 40mm dia. ISI marked including all accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal & salt as required.
169Supply & Fixing of Loop in Loop out Junction box with all materials (SP MCB 16Amp-1No of L & K/Legrand/Havells make,4way bakelite connector-1No,bakelite board-1No,1.5mm2 pvc insulated single core multistrand copper wire of Finolex/Anchor/Havells make-15mtr,16A DP Switch-1No of any ISI make) etc.
170Lawn LightingExcavation of pole pit in all kind of soil including rock of all verity of size 600mm x 600mm and depth 1200 mm with filling of sand to a height of 100mm ,100mm metal concrete and then laying foundation of Reinforced cement concrete (1:2:4) of 450mm x 450mm x 1000mm high with granite metal of nominal size 20mm to 25mm including side shuttering and grouting of foundation bolts and supply and erection of pole as specified above including watering and ramming it a required including provision for passage of cables and finishing the surface with 1:4 ratio cement plaster .
171S/F of 3mtr hotdipped decorative galvanised mild steel pole with grey powder finish of complete with all accessories including wiring, cabling etc. Equivalent to Havells eco model.
172S/F of Weather proof Junction box complete with all accessories including connectors,Bus bar Flats, glands as required with loop in loop out facility make of Sintex/Havells/L&T.
173S/F of decorative Lawn light of havells lantern top model/equivalent with aestheic appearance for decorative mild steel pole of reputed make with ISI marked as per direction pof engineer in charge.
174S/F 2 x 6 mm2 PVC Al Armoured Cable Of ISI Marked (Polycab/Nicco/Havels).
175Supply and laying of 32mm 6kgf/cm2 ID HDPE pipe of ISI marked as per direction of Engineer-in-charge.
176Cable trenching with HDPE pipe in all type of soil with excavation of earth,laying of cable with sand cushing and brick laying etc.& filling of loose soil upto ground level.
177S/F of Standard Earthing with G.I. earth pipe of 3mtr.Long 40mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required.
178Fabrication of 63A Outdoor type790 x480x330mm junction panel with Incoming: 63Amp MCCB four pole 16KA breaking capacity -1No,04 numbers of (25mm x 3mm size) 63Amp, 50kA Electrolytic copper busbar duly sleeved by colour coded PVC sleeve & supported by suitable size DMC insulator. Outgoing:-16Amp DP MCB of C'Series-6 Nos, 32Amp 4-Pole MCB 10KA breaking capacity-1 No,RYB indicator, Transporation and fixing charges etc. Protective device(MCCB & MCB should be make of L&T/Hager/Schnider/legrand).
179Solar Street LightSupply & Installation of 8 mtr long hot dip galvanized Octagonal pole with channel bracket manufactured from HT steel having base dia if 155 mm & top dia 70 mm or more and sheet thickness of 4 mm or more and 4 Nos. M30X850mm EN8 Grade foundation bolt. The octagonal pole shall be suitable to withstand 180 KM/HR or more wind speed by considering the weight & wind expose area . All accessories included like anchor plate, foundation nuts & bolts including required size of control cable from starter panel to each light . Make:- Bajaj/RR Ispat/Utkarsh /Vakrangee/Valmont
180Installation of 8 mtr pole on the adopter plate/Foundation after fixing th 100 watt AIO light in the pole by using suitable machineries by taking all safety precautions as per the direction of Engineer-In-Charge.
181Supply of Elegant look 100W AIO LED Solar Street lights having extruded alluminium housing, 180Wp or more Mono Crystalline Panel/Laminates fixed on the top of the luminaire housing, maintenance free 12.8 volts 96 Ah or more LiFePO4 battery(BIS certified) , BMS, MPPT charge controller, PIR sensor to provide 2 days (24 hrs ) back up . The luminaire is having IP 65 protection for critical components, IK 08 and having lumen output of > 15000 lumen and having minimum lumen efficacy >150 lm/w) as per LM 79 report third party NABL lab to justify the lumen output & lumen efficacy . Lenses should be provided on the LED chip for better lighting dstribution to avoid glare on human eyes. Both the luminaire and Mono Crystalline Panel must be manufactured in India. The Solar lighting company must submit the third party NABL lab reports to justify the luen efficacy,luminaire output , IK 08 and IP 65 protection ( In house NABL lab reports will not be acceptable). The Luminaire should be supplied along with adjustable type mounting bracket which can be fitted directly on the pole. The Solar Street light and solar panel having capacity of 180 Wp or more must be designed to take the wind load at 180 KM/HR wind speed (As per wind load test report ) . The Solar lighting companies should submit the lighting design report prepared by their in house lighting design for achieveing lux level of 40 lux if required as per the direction of engineer in charge .The Solar lighting manufacturer must submit the declaration letter by mentioning that complete solar light and the solar panel are manufactured in India ( Made in China product are not acceptable) and warranty certificate on their company's letterhead by mentioning warranty period as 5 years and necessary aftersales ervice will be provided through their tollfree base service network located within 100 KM from the project site. The Solar Street light manufacturer should have own NABL accredieted laborotory. The following test reports must be submitted for the technical acceptance of the products.1.LM 79 REPORT (Third party NABL lab only) , 2. IK 08 (Report of Third party NABL lab only for any wattage of AIO solar light ) , 3. IP 65 (Report of Third party NABL lab only , 4. Wind load test report of AIO Street light having 180 Wp or more capacity Solar Mono Panel suitable for 180 KM/Hr wind Speed.The AIO solar street light must complies to the following :1. EN50530 – MPPT Efficiency , 2.. IEC61547 , 3. IEC61000-3-2 – EMC , 4. IEC 60598-2-3 ,5. IEC 62109-1, ( The necessary test reports of third party NABL lab against the above must be submitted for any wattage of AIO Solar street lights for acceptance of product/TDS approval prior to start of the work. All the test reports must be in the name of solar lighting company )Make- (Philips/Panasonic/Wipro only )
182Supply, delivery ,installation and commissioning of LED Sign Board as per below specification of Box type Display Matter:-1-COMMUNITY HEALTH CENTRE, KOMNA (English Letter Red Colour) Letter Height 36 Inch.2- (Odiya Letter Red Colour) Letter Height 36 Inch3-Government of Odisha Logo (36X36 Inch)ACP Sheet:- Aluminum composite panel sheet(ACP) Outdoor type 3 mm (Viva, Alomax, Imperia Décor, Citi Bond ) Supporting of English Letter.Plastics Sheet: - 3mm Plastics Sheet (Yellow, Red) Color & Raising of 2.5 inch.(Gray) (Acast)L.E.D :- 0.3 to 1.5 Watts (Yellow, Red) Colour (Samsung, GE, Osaram, Philips, LG) Power Supply: - SMPS (Switch mode Power Supply), RPS (Regulated Power Supply).Input Voltage 160V to 230V A.C./ Out put Voltage 12V/24 Volts D.C. (Samsung, GE, Osaram, Philipes, LG). The panel should be supplied with astronomical timer and contactor for auto ON/OFF . The panel should be supplied with overvoltage and undervoltage relay with 20 kA TYPE 2 SPD.The panel should be outdoor type. The letter structure to be installed on the top of the building. It should withstand 200 km/hr wind velocity, MS Angle with primer and paint as per need for sustainable fixture 2 inch Ms pipe fastened with concerte. The cost is inclusive of all the structures, LED light, timer control panel and all other accessories. Make-Cosign/Sign media.
183Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 20mm dia C - PVC pipe Ground Floor
184First Floor
18525mm dia C - PVC pipeGround Floor
186First Floor
18732mm dia C - PVC pipe
188Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.(Jaquar make/ Plaza Make/ Cera make/ Hindwere Make)15mm dia CP angle stop cock(FLR-ACR-5053N)
18915mm dia CP two way bib cock(FLR-CHR-5041N)
19015 mm dia CP S.B. Bib cock(CON-CHR-037KN)
19115mm dia CP Long Body Bib cock (Con-CHR-107KN Jaquar make)
19225mm dia brass full way valve (Shakti make)
19332mm dia brass full way valve (Shakti make)
19440mm dia brass full way valve (Shakti make)
19515mm CP Extension piece
196125mm CP grating
19715mm size C.P. flange
198Supplying all materials , labour, T&P and fixing rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 mtr. lengthx0.25 mtr width KB brickwork in cement mortar (1:6) of 0.46m height in staging and 0.13mtr thick circular protection wall of 0.46mtr height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60mX1.60m and 0.10m thick ,RCC beam of 0.25mx0.30m and 3.40m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips and required steel reinforcement including centering and shuttering,watering,curing ,cost of all materials,conveyance of all materials to worksite , payment of royalty, all taxes etc.all complete as per approved drawing , P.H. specification and direction of Engineer-in-charge 2000 liters capacity PVC water storage tank roof of 2nd floor
199supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per direction of Engineer-in-charge.Ground Floor
200First Floor
201Supplying all materials , labour, T&P and cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak-proof as per P.H. specification and direction of Engineer-in-chargeGround Floor
202First Floor
203Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages including watering , curing , cost & conveyance of all materials to worksite, payment of royality, taxes etc all complete as per direction of the Engineer-in-charge.Ground Floor
204First Floor
205Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.110mm U-PVC SWR Pipe
206110mm U-PVC ‘P’ Trap(Supreme /Ashirvad/fInolex/Ori Plast Make)
207110mm U-PVC door bend(Supreme /Ashirvad/fInolex/Ori Plast Make)
208110mm U-PVC Plain bend(Supreme /Ashirvad/fInolex/Ori Plast Make)
209110mm U-PVC offset without ear(Supreme /Ashirvad/fInolex/Ori Plast Make)
210110mm U-PVC Cowl(Supreme /Ashirvad/fInolex/Ori Plast Make)
211110mm U-PVC S/Jn door(Supreme /Ashirvad/fInolex/Ori Plast Make)
212110mm U-PVC Plain tee(Supreme /Ashirvad/fInolex/Ori Plast Make)
213110mm U-PVC D/Jn door(Supreme /Ashirvad/fInolex/Ori Plast Make)
214110mm U-PVC Door tee(Supreme /Ashirvad/fInolex/Ori Plast Make)
215110mm U-PVC Socket(Supreme /Ashirvad/fInolex/Ori Plast Make)
216Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge(Jaquar make/ Plaza Make/ Cera make/ Hindwere Make)10 ltr. Capacity pvc L.L. cistern with 32mm. Dia CP long flush bend ( Slimline-white-Parryware make )
217Supplying all materials,labour,T&P and fixing Flat back lipped wall (Mini stall urinal -630mmx180mm) urinal of the following sizes including connecting the urinal with 32mm. dia pvc waste pipe 910mm. long by means of white lead mixed with chopped hemp, fixing 32mm. dia CP dome waste, 15mm. dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc. all complete as per specification and direction of the Engineer in charge Half stall urinal(Jaquar make/ Plaza Make/ Cera make/ Hindwere Make)
218Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet(European type W.C. pan)with integral 'p' or 's' trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing , cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge(Jaquar make/ Plaza Make/ Cera make/ Hindwere Make)European water closet with 'p' trap plain(Hindware/Parryware/Neycer make)
219EWC(Matrix set)No.70002(P-18)
220Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered 'Hot' and 'Cold' with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, cost & conveyance of all materials to worksite, payment of taxes etc. all complete as perP.H specification and direction of the Engineer-in-charge(Jaquar make/ Plaza Make/ Cera make/ Hindwere Make)Halfpedestal basin(560x450)Hindware No.91049+91115
221Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge25mmx600mm long CP towel rail
222Towel ring
223Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rail complete fixed to wooden plugs with CP screws as per specification and direction of Engineer in charge.600mmx125mm plate glass shelf with CP/NP guard rails.
224Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm.thick A.C. sheet or ply wood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of Engineer in charge.600mmx450mm size B.E mirror (swivelled type)
225Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in chargeCP soap holder
226Supplying all materials , labour, T&P and cutting holes through existing brick or laterite masonry wall for taking U-PVC pipes and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge
227Supplying all materials , labour, T&P and cutting of RCC chajja for taking HCI or U-PVC pipe and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge
228Supplying all materials ,labour ,T&P and constructing Inspection Chamber of inside size 760mmx760mmx460mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-chargeInside size 76cmx76cmx46cm with 18” dia RCC MH cover
229Supplying all materials ,labour ,T&P and constructing gully trap chamber of inside size 250mmx250mm with 8cm thick RCC precast cover slab in cement concrete (1:2:4) mix using 12mm size crusher broken HG chips, foundation concrete (1:4:8) using 40mm size crusher broken HG metal on bed and around trap, KB brick work in cement mortar (1:6) in foundation and plinth and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap, 150mmX150mm size CI grating etc.all complete as per drawing, specification and direction of Engineer-in-charge
230Supplying all materials, labour, T&P and providing and fixing ceramic tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) ( 1 cement : 1 sand ) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge ( ceramic floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 of size Kajaria/Somany/Johnson tile 60cmx60cm special printed series to be pre-approved by the Engineer-in-charge )Kajaria/Somany/Johnson tile 30cmx30cmGround Floor
231First Floor
232Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.Ground Floor
233First Floor
234Supplying all materials, labour, T&P and providing and fixing porcelain glazed tiles in dado skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge( ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm conforming to IS 13753 of size Kajaria/Somany/Johnson tile 60cmx30cm special plain / printed series to be pre-approved by the Engineer-in-charge )Kajaria/Somany/Johnson tile 45cmx30cmGround Floor
235First Floor
236Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 650kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. of make Rajshri Plastiwood/ Alstone/Aramstrong or euivalant as per direction of Engineer-in-charge.
237Factory made Solid WPC door frame of size 90mmx45mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification. of make Rajshri Plastiwood/ Alstone/ Aramstrong or euivalant as per direction of Engineer-in-charge.
238Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) pure chill 80 PSS UV of size 750 x 570 x 1350mm hight with water storage capacity 80 liter's along with 2 noa of faucets 1 for cold water and 1 for normal water including a flow of 1.5 ltr per munite etc all complete as per approved drawing , specification and direction of the Engineer in chargeAqua guard pure Chill 80 PSS UV
239Ext. S/D PortionSupplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufacture's specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge150mm dia P.V.C. pipe
240Supplying all materials labor T&P and constructing MH chamber of sizes earth work in excavation in all kinds of soil CC(1:1:8) with black granite chips size 46mm brick work with K.B. brick having crossing strength not less than 75 Kg /CM2 to 90 Kg/CM2s in CM(1:6)12mm C.P(1:8) inside MH chamber over benching with cement slush pointing (1:3)outside the MH chamber providing painting MS or CI step iron RCC(roof of slab with CC(1:2:4)with black granite chips size 12mm bending binding tying the grills placing of the reinforcement providing RCC color of required size refilling the cavity around the MH chamber with excavated earth including channeling the bed of MH etc all complete as per PH specification. MH size 0.91m x 0.91 m with 0.45 m (18” dia RCC Cover )
241Supplying all materials labour T&P and constructing 1.80m dia x 2.60 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site.
2421 no 30 users RCC septic tankEarth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of the Engineer-in-Charge.
243Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general.
244Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge.
245Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
246Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
247Supplying all materials, labour, T&P and providing cement concrete (1:1.5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
248Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
249Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeR.C.C beams,columns,girder and bressmer etc.
250Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
251Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
252Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge.
253Supplying all materials, labour T&P for providing fitting & fixing 150mm x 150mm SW Tee in wall including filling the recess with cement concrete (1:2:4) with 12mm size HG chips all complete including watering curing conveyance of all materials to work site payment of royalty all complete as per specification and direction of Engineer in charge.
254Supplying all materials labour T&P filling sand in lavatories well watered and rammed including lead of materials to work site.
255RAIN WATER HARVESTING SYSTEM(PIT)(2 nos)Earth work in hard soil or gravelly soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge.
256Supplying all materials, labour, T&P and providing cement concrete (1:4:8) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
257Supplying all materials, labour, T&P and providing brick work with Fly ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:6) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
258Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork with cement punning and bitumen painting over top of wall including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
259Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
260Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeR.C.C floor and roof slabs, landings, balconies, projecting sunshades and
261Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor
262Supplying all materials, labour, T&P and providing cement concrete (1:1½:3)with 12mm size hard broken granite chips including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floorSlab
263providing and filling filter media40mm Boulder-
26420mm washed gravel--
265Course sand-
266Providing fitting & fixing M.S.grill cover over the harvesty pindi
267Sinking of tube well(200) for PITLabour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore onlyDrilling of 200mm dia bore00 mtr to 25mtr
268Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials.200mm dia PVC pipe
269cost of 200mm pvc pipe
270Cutting slot in casing pipe for recharge of rain water
271labour for packing gravel outside the tube well
272Cost of washed gravel Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57917763
AUTHORITY Government Departments
TENDER VALUE 3.12 Crore
LAST DATE 22-10-2026
Authority
Authority Name Road And Building Department
Work Description Tender for Development & Renovation Of Chc Komna (Ama Hospital Phase Ii) In The District Of Nuapada For The Year 2026-27.
Basic Detail
Tender No CCE (R and B) BGR / 03 /2026-27
Bidding Type Tender
Location
City Nuapada
State Odisha
Key Dates
Publish Date 07 Oct 2026
Submission Date 22 Oct 2026
Open Date 23 Oct 2026
Finance
Tender Value 3.12 Crore
Tender Fee 10000
EMD 3.13 Lakhs
Exemption Available
Document List
93d8d958-96f8-4c2a-8204-c1c772849b62.html
BOQ_612687.xls
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Oct 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

93d8d958-96f8-4c2a-8204-c1c772849b62.html

xls

BOQ_612687.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender