Tender For Develpoment & Renovation Of Chc Khariar Road (Ama Hospital Phase Ii) In The District Of Nuapada For The Year 2026-27
Tender Overview
Project Description
Tender for Develpoment & Renovation Of Chc Khariar Road (Ama Hospital Phase Ii) In The District Of Nuapada For The Year 2026-27
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 13-Oct-2026 | 7th corrigendum | Technical Bid | 22-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious materials, dressing of sides and bottom and backfilling with approved material. |
| 2 | Providing and filling foundation trenches with sand in layers not exceeding 150mm thick including watering and compacting including all leads and lifts for finish item of work as per clause 1500 of MORT&H specification. |
| 3 | Cement concrete (1:3:6) in foundation and floor i;e below the base course of terrazo flooring using 4cm (1½”) size black crusher hard broken granite chips metal of approved quality and from approved quarry, including lowering, laying concrete, watering curing etc. complete to required level laid in layers not exceeding 1'-6\\" thick including cost, conveyance, royalities of all materials and cost of all labour, T&P. required for the work etc. complete as per direction of the Engineer-in-charge |
| 4 | Re-inforced Cement Concrete M-20 mix with stone aggregate 20mm nominal size mechanicaly mixed & vibrated in foundation upto a depth of 1.5m below ground level and 1.5M above ground/bed level for finished item work as per clause No. 1000/1500/1700/2200 of MORT&H specification. Column Footing |
| 5 | Plinth Beam |
| 6 | Column in Superstructure |
| 7 | First Floor |
| 8 | Lintel (Ground Floor) |
| 9 | First Floor |
| 10 | Chajja |
| 11 | Roof Beam |
| 12 | Roof Slab |
| 13 | DrainBed |
| 14 | Cover Slab |
| 15 | Providing HYSD reinforcement for RCC works in substructure including bending, binding and placing in position for finished item work as per drawing and as per clauses 1000/1600 of MORT&H specification. |
| 16 | Plain cement concrete (1:4:8) nominal mix in foundation as per Drawing and Technical Specification |
| 17 | .Plain cement concrete (1:2:4) nominal mix in foundation as per Drawing and Technical Specification |
| 18 | Construction of embankment with approved materials obtained from borrow pits with all lifts and leads transportating to site within a lead of 5km and spreading grading to required slope and compacting to meet reqirement of table 300-2 and Clause-305 of MoRT&H specifications for Road & Bridge Works (4th Revision).(AR-P-157/35) |
| 19 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. as per clause 406 of MoSRT&H Specification for Road . |
| 20 | Supplying and fixing of pre cast inter locking concrete block 80mm thick with crushing strength as per drawing and technical specification clause 1504 of MORTH and specification 6919-11-1986 with all cost of materials, labour, carriage etc complete (data for 225 sqm) |
| 21 | Providing of M.S. Sq Pipe , Door / Window / Grill gates made out of M.S. Angle, flat, sheet etc. including cost, conveyance, taxes of all materials and labour (T&P) etc. complete. |
| 22 | Supplying and fixing Colour G.C.I sheeet on roof drilling hole in wind ties including fixing of ridges valley wind ties etc excluding cost of fittings per 1 sqm. |
| 23 | Painting two coats with approved Enamel Paint on Steel surface over a coat of Red Oxide Primer in Ground Floor |
| 24 | First Floor |
| 25 | Fly ash brick masonry in cement mortar (1:6) using 25 Cm. x 12 Cm. x 8 Cm. size C.M(1:6) size fly ash bricks having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance + 2 % in foundation and plinth including cost, conveyance, royalty, loading, unloading of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-Charge. Foundation and Plinth |
| 26 | Fly ash brick masonry in cement mortar (1:6) using 25 Cm. x 12 Cm. x 8 Cm. size C.M(1:6) size fly ash bricks having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance + 2 % in Superstructure including cost, conveyance, royalty, loading, unloading of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-Charge. |
| 27 | First Floor |
| 28 | Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joint, including watering and curing, rounding of cormers, providing grooves where ever necessary with cost, conveyance, royalties and taxes of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. |
| 29 | First Floor |
| 30 | Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ev r necessary with cost, conveyance, royalties and taxes of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. |
| 31 | First Floor |
| 32 | 6 mm thick cement plaster (1:4) to R CC surfaces finished smooth including closed deep chiping and slury treatment. including watering and curing, rounding of corners, providing grooves where ev r necessary with cost, conveyance, royalties and taxes of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. |
| 33 | Priming one coat with approved Water Bound Wall cement Primer on Plastered Surface in Ground Floor |
| 34 | First Floor |
| 35 | Finishing surface of walls with cement based wall putty (water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials labour T & P etc. as per direction of Engineer -In -charge. in Ground Floor |
| 36 | Plastic Emulsion painting two coats to inside wall surface with over a coat of primer with any approved shade including cost of all materials and labour (T&P) etc. complete as per the direction of Engineer-in-Charge. |
| 37 | First Floor |
| 38 | Finishing out side wall surface with Weather Coat (I.S.I) two coats with over a coat of primer with any approved shade including cost of all materials and labour (T&P) etc. complete as per the direction of Engineer-in-Charge. |
| 39 | First Floor |
| 40 | Supplying Fitting, fixing Two Track UPVC Sliding framed window of approved make with 6mm thick glass of approved quality complete with frame shutters and all fitting and fixtures complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge |
| 41 | Supplying Fitting, and fixing of openable UPVC Doors with Door frame of approved make with 6mm thick glass of approved quality complete with frame shutters and all fitting and fixtures complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge |
| 42 | Supplying, fitting & fixing of Vitrified colour printed series tiles in floors of size 600mmx 600mm of approved make confirming to IS:13755 laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge (for New Work only ) |
| 43 | Supplying, fitting & fixing of Vitrified colour printed series tiles in dadoes, skirting and risers of steps of size 600mmx 600mm of approved make confirming to IS:13755 laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge |
| 44 | Supplying, fitting & fixing of CeramicTiles of minimum 7-8mm thick of approved make in floors over 20mm thick bed of cement mortar 1:4 jointed with cement slurry mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance, taxes & royalties of all materials, labour with T&P complete in all respect.(Data for 10 Sqm ) |
| 45 | Supplying, fitting & fixing of Ceramic Tiles of minimum 6.5mm to 6.7mm thick of approved make in dadoes, skirting and risers of nsteps laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge |
| 46 | Supplying ,fitting and fixing of ISMB Sections for cow catcher (16.8m x 1.5m) including labour for lifting,hoisting and placing in position to required size and length ,pre fabricating by cutting to sizes,priming including cost of all materials,cost of all labour,loading,unloading at site,all accessories,T&P required for the work complete in all respect as directed by Engineer in Charge.Providing ,Supplying & Fixing of 80mm dia heavy gauge G.I. Pipe(Jindal brand steel) for cow catcher (16.8mX1.5m) including labour for lifting,and placing in position to required length,pre fabricating by cutting to required length,priming including cost of all materials, cost of all labour,loading,unloading at site ,all accessories,T&P required for the work complete in all respect as directed by Engineer in Charge.Supplying ,fitting and fixing of 25x6 MS Flat including labour for lifting and placing in position to required length, pre fabricating by cutting to require length ,priming including cost of all materials,cost of all labour,loading,unloading at site,all accessories,T&P required for the work complete in all respect as directed by Engineer in Charge. |
| 47 | Supplying fitting and fixing of stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90 mtrs C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in staircase as per approved design and specification, buffing, polishing etc with coist, conveyance, taxes of all materials, labour and T&P required for the work all complete in all respect |
| 48 | Filling foundation and plinth with excavated earth and technical specifications as per Section 2100 of MoRT&H Specifications for Road & Bridge works (4th Revision). |
| 49 | Internal E.I.Works:-Parking Shed,Main Gate,Security Room & Ramp Area :-Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked, Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal and with 6A modular type ( flame retardant type) switch ISI marked, Make-Schneider(Zencelo)/legrand( Myrius)/ Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retardant type) Make-Schneider (Zencelo)/legrand( Myrius)/Panasonic (vision) of suitable size, modular box with 1.5 sq. mm FRLS PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. All the switches & sockets should be warranted for a replacement period of 2 years against defects with ncessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.GROUP-A |
| 50 | GROUP-B |
| 51 | GROUP-C |
| 52 | Supplying,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type & other required accessories of ISI marked as approved as per direction of Engineer-in-Charge. Make of Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (Maximum 02 nos point in one circuit).All the switches & sockets should be warranted for a replacement period of 2 years against defects with ncessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 53 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket (modular type with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of Engineer-in-charge. Make-Schneider(Zencelo)/legrand(Myrius)/ Panasonic (vision) (For equipment power) All the switches & sockets should be warranted for a replacement period of 2 years against defects with ncessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 54 | Supplying,fixing of 2x6A+1X16A Plug on the separate board with complete fitting by 2 nos of 6A + 1 no of 16A switch & socket(modular type) with suitable size modular box & metallic cover plate (both side) including supplying of all required accessories of ISI marked as approved as per direction of Engineer-in-charge.Make-Schneider(Zencelo)/legrand (Myrius)/Panasonic (vision) (For equipment power) (Maximum 02 nos point in one circuit).All the switches & sockets should be warranted for a replacement period of 2 years against defects with ncessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 55 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/ Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size, Make-AKG/BEC/Precision/ Norpak/Anchor/Kinjal as required as per direction of Engineer-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 1 no of single core 1.5 sq. mm copper wire for earth continuity conductor in 20 mm dia non metallic heavy duty conduit (LSB to Light & Fan Points/LIGHT CKT) (2X1.5 +1X1.5) |
| 56 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable, Make- Finolex/Anchor/ Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size, Make-AKG/BEC/Precision/ Norpak/Anchor/Kinjal as required as per direction of Engineer-in-Charge. 1 no single core 1.5 sq. mm copper wire for phase for Invertor wiring in 20 mm dia non metallic heavy duty conduit (For Invertor wiring)) (1X1.5) |
| 57 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable, Make- Finolex/Anchor/ Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/ Norpak/Anchor/Kinjal as required as per direction of Engineer-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 1 no of single core 1.5 sq. mm copper wire for earth continuity conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/6A PLUG/ UPS POINT ) (2X2.5+1X1.5) |
| 58 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable, Make- Finolex/Anchor/ Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/ Norpak/Anchor/Kinjal as required as per direction of Engineer-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 1 no of single core 1.5 sq.mm copper wire for earth continuity conductor in 20 mm dia non metallic heavy duty conduit.(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 59 | Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of POLYCAB/KEI/HAVELLS/GLOSTER,make, ISI marked with all other related materials as per direction of Engineer-in-Charge. Ncessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials (From MCB DB to Light Points at Vehicle Parking Shed) |
| 60 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer-in-charge. (Make-Schneider(Zencelo)/legrand( Myrius)/ Panasonic (vision) |
| 61 | Supplying, Installation, Testing and Commissioning of 1200 mm sweep white/milky colour BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min, Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix/Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engineer-in-Charge, Replacement Warranty will be 4 years. |
| 62 | Supplying and fixing of Energy efficient surface/recess mounted square/round shape 18 W LED luminaire consisting of white powder coated, die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens,CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV, L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V A.C.supply as required as per direction of Engineer-in-Charge. (Make: Panasonic/LT/Havells/ Philips/Wipro/Crompton/Bajaj).The luminaire should be Replacement Warranty for 2 years.(For Ramp Area) |
| 63 | Supplying & Fixing of 20watt LED Mini Flood Light (CDL Flood Light) Outdoor Lamp Cool white, Water proof set of Bajaj/Philips/Havells make.(For Parking Area lighting) |
| 64 | SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc. as required as per direction of Engineer-in-Charge. (Make: Panasonic/ LT/ Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty for 2 years . |
| 65 | S/F of 90watt LED Street Light,120 lm/w efficiency,IP PC Lens new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic cover.(Make:-Panasonic/LT/Havells/Philips/Wipro/Crompton/Bajaj) (5 Years Warranty) |
| 66 | Supply and Fixing of GI bend pipe for street light including all accessories i.e clamp or jam lock etc. |
| 67 | S/F of decorative outdoor water proof IP54 Gate Light with 30Watt LED Lamp of Bajaj/Havells/Phillips make. |
| 68 | Supplying and laying of one number PVC insulated armoured and PVC sheathed XLPE AL.conductor power cable of 1.1 KV grade,ISI marked of POLYCAB/KEI/HAVELLS /GLOSTER MAKE of following size cables as per direction of Engineer-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials3.5core x 50 sq. mm Aluminium Armoured Cable (From nearest LT Pole to 100 Amp ICTPN Main Switch at Security Room) |
| 69 | 2 core x 16 sq. mm Aluminium Armoured Cable (From 100 Amp TPN Busbar at Security Room to 32Amp ICDP Main Switch at Vehicle Parking Shed) |
| 70 | Laying of PVC Insulated PVC Seathed/XLPE power cable of 1.1 KV grade size above 25 sq.mm and not exceeding 120 Sq.mm in surface with Shaddle and Screw etc. as required as per direction of Engg.-in-charge.(For 50 Sq mm Cable) |
| 71 | Laying of PVC Insulated PVC Seathed/XLPE power cable of 1.1 KV grade size upto 25 sq.mm and not exceeding 25 Sq.mm in surface with Shaddle and Screw etc. as required as per direction of Engg.-in-charge.(For 16Sq mm Cable) |
| 72 | Laying of PVC Insulated PVC Seathed /XLPE power cable of 1.1 KV grade size above 25 Sq.mm and not exceeding 120 Sqmm direct in ground in the trench in one horizontal formation including excavation,sand cushing, protection covering and refilling the trench etc. as required as per direction of Engg.-in-charge.(For 50 Sq.mm Cable) |
| 73 | Supply & Fixing of 32 amp ICDP Main switch of an approved ISI Make ( L&T/ Havells/Anchor)(For Vehicle Parking Shed) |
| 74 | Supply & Fixing of 100 amp ICTPN Main switch of an approved ISI Make ( L&T/ Havells/Anchor)(To be installed at Security Room for power supply to Parking Shed,Main Gate & Security Room along with nearest High Mast Lights) |
| 75 | Supply & Fixing of 100 amp TPN Copper Busbar with suitable enclosure box of an approved ISI Make ( L&T/ Havells/Anchor).(To be installed at Security Room) for power supply to Parking Shed,Main Gate & Security Room along with nearest High Mast Lights) |
| 76 | Supplying and fixing of 4 Way Double Door MCB Distribution Box Horizontal Type as per IEC 61439-3 with configuration of incoming 2 modules & out going-2 modules,suitable for Flush mounting and Surface mounting with metal door. Warranty on DB is 3 years. |
| 77 | Supplying and fixing 16 Amps rating,C series,10KA breaking capacity, DP, 240 volts, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB FB200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engineer.-in-Charge. The RCCB should be Replacement Warranty for 1 year. |
| 78 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C' series,10KA breaking capacity, single pole MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200. the existing MCB DB complete with all connections as per direction of Engineer-in-Charge. Warranty on MCB is 1 year. |
| 79 | Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers in 40mm dia G.I.Pipe of 3 mtr. length inside ground including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and refilling as usual as per direction of Engineer-in-charge. |
| 80 | Providing and fixing 25mm x 5 mm GI strip laying from G.I.plate to upwards on surface or in recess for connections etc. as required as per direction of Engineer-in-Charge. |
| 81 | Supply & Laying of SWG No.8 G.I. Earth Wire of any ISI make for laying to maintain earth continuity. |
| 82 | S/F of 2000 VA UPS( Microtake/Luminous) with 2nos 150 AH Sine Wave inverter battery & trolley set. ( make:- Exide/Amaron/ Luminous or equivalent) ( for different sections inside CHC Building) |
| 83 | SPLIT AC1.5 TR high wall 5 star inverter type split A.C machine (BTU/Hr-18000)with copper condensor & evaporator having ambient temperature 52 degree celcius with comprehensive 1 year warranty,5 years warranty on PCB, 5 years warranty on compressor (Make:O-General/Diakin/Mitsubishi/Hitachi/eq.) |
| 84 | REFRIGRANT PIPINGSupply,installation of hard/soft copper refregrant piping of size 5/8 inch and 1/4 inch for suction and liquid line with 3 corex4 sqmm FRLS Copper control cable alongwith 25 mm weather proof closed cell nitrile insulation ,complete with fitting of bends and other nesessary material to complete the job.1 TR to 3 TR high wall split A.C |
| 85 | FRAME WORKSupply,installation & fabrication of MS base frame for both indoor and outdoor unit and other nesessary material to complete the job.1 TR to 3 TR high wall split A.C |
| 86 | DRAIN PIPINGSupply,installation & fabrication of Insulated drain water piping from indoor to nearest drain point separate to all and other nesessary material to complete the job.25mm nom. Dia pipe |
| 87 | CONTROL CABLESupply,laying of control cable and other nesessary material to complete the job.For 1 TR to3 TR high wall split A.C |
| 88 | Supply and fixing of 4kVA Voltage stabilizer (Make-V-Guard/ Microtek) |
| 89 | S/F of 25Amp AC starter switch Havells/ legrand /or equivalent make. |
| 90 | Servo stabilizerSupply,Installation,Testing & Commissioning of 250KVA (200KW) Servo Control Voltage Stabilizer (SCVS) having Specification & Special Features such as 3-phase In & 3-phase Out,Independent phase voltage controller,Under voltage/Over voltage protection,Alarm & Cut off at Output volts,Overload and Short Circuit protection,Auto-Manual Operation,Voltage limit indicator,Output Voltage adjustable,Input/Output voltage monitoring,Oil Cooled,Input Voltage Range:-300-480Volts.Output Voltage:-400VAC +/ -3%,Frequency-50 Hz +/- 3 Hz,Response time-1 milli second,Rate of Correction-105V/Sec, Efficiency Better than 98% and 100% Continuous Duty Cycle etc.(Make of APS/SM-VOLTSMART/Servomax/Microtek) |
| 91 | 250KVA Servodistribution set up with installation of 500A Changeover switch with rotary switch with enclosure box -1no, 500A Busbar FP-1 Set,Earth wire -15mtr including all required secondary accessories as per direction of engineer in charge (switch gear make L&T/Legrand/Havells/eq) |
| 92 | Supply of 3&1/2 Core 300sq.mm PVC Alluminium Armoured Cable of Havells/Polycab/KEI/Gloster make. |
| 93 | Laying of PVC Insulated PVC Seathed/XLPE power cable of 1.1 KV grade size not exceeding 400 Sq.mm from 120 Sq.mm in surface with Shaddle and Screw etc. as required as per direction of Engineer-in-charge.(For 300 Sq.mm Cable) |
| 94 | INTERCOM SYSTEM:-IP-PBXSupply, Installation,Testing & Commisioning of Grand Stream UCM-6302, IP PBX System support upto 1000Users and minimum 60 concurrent calls, integrated 2 PSTN trunk FXO ports through External Gateway, 2 analog telephone FXS ports with lifeline capability and up to 50 SIP trunk accounts, Gigabit network ports with Integrates PoE, USB, SD card, Supports up to a 5-level IVR (Interactive Voice Response), Supports any SIP video endpoint that uses the H.264, H.263 or H.263+ codecs.Make: Grandstream/Panasonic/Beetel |
| 95 | Supply, Installation,Testing & Commisioning of IP based PoE Phone with single lie Displaywith 2 Ethernet Port. Make: Grandstream/ Panasonic/ Beetel |
| 96 | Complete Installation charges with all required materials to complete job. |
| 97 | Cable:-Supply,Installation,Testing & Commissioning of 4 pair Cat6 U/UTP Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Tyco/ Legrand/ Panduit |
| 98 | ConduitsSupply, delivery and laying of following sizes of 2mm thick PVC Conduit concealed in wall/ column/ roof slab of the building alongwith other accessories and 18 swg GI wire complete for Electrical Wiring/Telephone / TV & Data cable wiring as required and as per direction of Engineer-in-charge. (Make:- NORPACK/ AKG/ BEC/ PRECISION)20mm dia |
| 99 | 25mm dia |
| 100 | Indoor LED monitor Provision of samsung crystal 65AU7700,65inch ULTRA HD smart LED 4K TV/Vertical mount display of equivalent make supports are solution of 4K,3840 x2160 pixels has a refresh rate of 60Hz and an aspect ratio of 16:9 video format support on the TV . The port availability includes 2 x USb 2.0ports 3xHDMI port x VGA Input port and one digital audio output port wireless connectivity involves wifi and blue tooth 5.0 with set up box & sound sytem arrangements of make Bosch/sony /JBL/ samsung etc. complete with all accessories as per direction of engineer in charge. |
| 101 | Outdoor LED WallOutdoor LED Wall Provision of high class P6 outdoor SMD RGB Module(192 x192) MM Driving Ic-5M/ICN Brand:quangli/Unilumin as per direction of engineer in charge. |
| 102 | Provision of Sending card/Processor model A4Brand Huidu as per direction of engineer in charge. |
| 103 | Provision of power supply SmPS 60A 5V Brand Rong Elecric as per direction of engineer in charge. |
| 104 | Provision of power supply SmPS40A 5V Brand Rong Elecric as per direction of engineer in charge. |
| 105 | Provision of QMS backend server software with database as per direction of engineer in charge. |
| 106 | Provision of Outdoor MS iron cabinet size 960 x 960 MM make as per direction of engineer in charge. |
| 107 | Provision of Monopole as per direction of engineer in charge. |
| 108 | Provision of Outdoor Iron structure per direction of engineer in charge. |
| 109 | Provision of ACP Board only shed as per direction of engineer in charge. |
| 110 | Provision of charges for transportation & wiring as per direction of engineer in charge. |
| 111 | Provision of Installation,testing ,power supply with cable,& commissioning charges as per direction of engineer in charge. |
| 112 | Provision of Receiving Card Modl No R-512/R508 Brand Huidu as per direction of engineer in charge. |
| 113 | S/F of mounting structure for Outdoor led wall base structure, Channel frame, background structure complete with all accessories |
| 114 | Campus Lighting:-Supply of 9 mtr long hot dip galvanized Octagonal pole with channel bracket (for mounting at least 8 nos. of flood light) manufactured from HT steel having base dia of 210 mm & top dia 90 mm or more and sheet thickness of 4 mm or more and 4 Nos. M30X850mm EN8 Grade foundation bolt. The octagonal pole shall be suitable to withstand 200 KM/Hour or more wind speed by considering the weight & wind expose area . All accessories included like anchor plate, foundation nuts & bolts including required size of control cable from starter panel to each light . Make:- Bajaj/RR Ispat/Utkarsh /Vakrangee/Valmont. |
| 115 | Supply,Installation,Testing & Commissioning of 250 watt LED Flood Light with CCT 6000/5700/3000K Luminaire with efficiency more than 120 Lumens/watt and indivisual LED with secondary optics made in high pressure die-cast housing with toughned glass and heat sink in Aluminium extrusion with IP 66 protection complete of Havells/Panasonic/Bajaj/Phillips/Crompton/LT make.(5 years warranty) |
| 116 | Supply & fixing of Decorative Round Arm bracket with all accessories suitable for fixing of 8 Nos Flood light fittings including Clamp & Nut Bolts. |
| 117 | Supplying and laying of one number PVC insulated armoured and PVC sheathed XLPE AL. conductor power cable of 1.1 KV grade,ISI marked of POLYCAB/KEI/HAVELLS MAKE of following size cables as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials4 core x 16 sq. mm PVC Aluminium Armoured Cable |
| 118 | 4core x 6 sq mm PVC Aluminium Armoured Cable |
| 119 | Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of POLYCAB/KEI/HAVELLS/GLOSTER,make, ISI marked with all other related materials as per direction of Engineer-in-Charge. Ncessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials (For connection from Junction box to light) |
| 120 | Supply & Fixing of Standard Earthing with G.I Earth pipe 3 Mtr. Long 40mm dia. ISI marked including all accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal & salt as required. |
| 121 | Supply & Laying of SWG No.8 G.I. Earth Wire of any ISI make for laying to maintain earth continuity. |
| 122 | Supply & Fixing of Loop in Loop out Junction box with all materials (TPN MCB 16Amp,10KA,C'Series -1No & DP MCB 10 Amp,10KA,C'Series -3 Nos of L&T/Legrand/Havells make,4way bakelite connector-1No,bakelite board-1No etc.) |
| 123 | Fabrication,Supply & Installation of 63A Outdoor type790 x480 x330mm Junction panel with Incoming: 63Amp MCCB four pole 16KA breaking capacity -1No,04 numbers of (25mm x 3mm size) 63Amp,50kA Electrolytic copper busbar duly sleeved by colour coded PVC sleeve & supported by suitable size DMC insulator. Outgoing:-32Amp 4-Pole MCB 10KA breaking capacity-2 Nos, RYB indicator, Transporation and fixing charges etc.Protective device(MCCB & MCB should be make of L&T/Hager/Schnider/ legrand). |
| 124 | S/F of 90watt LED Street Light,120 lm/w efficiency,IP PC Lens new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic cover.(Make:-Panasonic/LT/Havells/Philips/Wipro/Crompton/Bajaj) (5 Years Warranty) |
| 125 | Supply and Fixing of GI bend pipe for street light including all accessories i.e clamp or jam lock etc. |
| 126 | Lawn LightingExcavation of pole pit in all kind of soil including rock of all verity of size 600mm x 600mm and depth 1200 mm with filling of sand to a height of 100mm ,100mm metal concrete and then laying foundation of Reinforced cement concrete (1:2:4) of 450mm x 450mm x 1000mm high with granite metal of nominal size 20mm to 25mm including side shuttering and grouting of foundation bolts and supply and erection of pole as specified above including watering and ramming it a required including provision for passage of cables and finishing the surface with 1:4 ratio cement plaster . |
| 127 | S/F of 3mtr hotdipped decorative galvanised mild steel pole with grey powder finish of complete with all accessories including wiring, cabling etc. Equivalent to Havells eco model. |
| 128 | S/F of Weather proof Junction box complete with all accessories including connectors,Bus bar Flats, glands as required with loop in loop out facility make of Sintex/Havells/L&T. |
| 129 | S/F of decorative Lawn light of havells lantern top model/ equivalent with aestheic appearance for decorative mild steel pole of reputed make with ISI marked as per direction of Engineer -in-charge. |
| 130 | 4 core x 16 sq. mm PVC Aluminium Armoured Cable (From Highmast Incoming Panel to 63A Outdoor Panel) |
| 131 | S/F 2 x 6 mm2 PVC Al Armoured Cable Of ISI Marked (Polycab/Nicco/Havels). |
| 132 | Supply and laying of 32mm 6kgf/cm2 ID HDPE pipe of ISI marked as per direction of Engineer-in-charge. |
| 133 | Cable trenching with HDPE pipe in all type of soil with excavation of earth,laying of cable with sand cushing and brick laying etc.& filling of loose soil upto ground level. |
| 134 | S/F of Standard Earthing with G.I. earth pipe of 3mtr.Long 40mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required. |
| 135 | Fabrication,Supply & Installation of 63A Outdoor type790 x480x330mm junction panel with Incoming: 63Amp MCCB four pole 16KA breaking capacity -1No,04 numbers of (25mm x 3mm size) 63Amp,50kA Electrolytic copper busbar duly sleeved by colour coded PVC sleeve & supported by suitable size DMC insulator. Outgoing:-16Amp DP MCB of C'Series-6 Nos, 32Amp 4-Pole MCB 10KA breaking capacity-1 No,RYB indicator, Transporation and fixing charges etc. Protective device(MCCB & MCB should be make of L&T/Hager/Schnider/legrand). |
| 136 | Solar Street LightSupply & Installation of 8 mtr long hot dip galvanized Octagonal pole with channel bracket manufactured from HT steel having base dia if 155 mm & top dia 70 mm or more and sheet thickness of 4 mm or more and 4 Nos. M30X850mm EN8 Grade foundation bolt. The octagonal pole shall be suitable to withstand 180 KM/HR or more wind speed by considering the weight & wind expose area . All accessories included like anchor plate, foundation nuts & bolts including required size of control cable from starter panel to each light . Make:- Bajaj/RR Ispat/Utkarsh /Vakrangee/Valmont |
| 137 | Installation of 8 mtr pole on the adopter plate/Foundation after fixing th 100 watt AIO light in the pole by using suitable machineries by taking all safety precautions as per the direction of EIC. |
| 138 | Supply of Elegant look 100W AIO LED Solar Street lights having extruded alluminium housing, 180Wp or more Mono Crystalline Panel/Laminates fixed on the top of the luminaire housing, maintenance free 12.8 volts 96 Ah or more LiFePO4 battery(BIS certified) , BMS, MPPT charge controller, PIR sensor to provide 2 days (24 hrs ) back up . The luminaire is having IP 65 protection for critical components, IK 08 and having lumen output of > 15000 lumen and having minimum lumen efficacy >150 lm/w) as per LM 79 report third party NABL lab to justify the lumen output & lumen efficacy . Lenses should be provided on the LED chip for better lighting dstribution to avoid glare on human eyes. Both the luminaire and Mono Crystalline Panel must be manufactured in India. The Solar lighting company must submit the third party NABL lab reports to justify the luen efficacy,luminaire output , IK 08 and IP 65 protection ( In house NABL lab reports will not be acceptable). The Luminaire should be supplied along with adjustable type mounting bracket which can be fitted directly on the pole. The Solar Street light and solar panel having capacity of 180 Wp or more must be designed to take the wind load at 180 KM/HR wind speed (As per wind load test report ) . The Solar lighting companies should submit the lighting design report prepared by their in house lighting design for achieveing lux level of 40 lux if required as per the direction of engineer in charge .The Solar lighting manufacturer must submit the declaration letter by mentioning that complete solar light and the solar panel are manufactured in India ( Made in China product are not acceptable) and warranty certificate on their company's letterhead by mentioning warranty period as 5 years and necessary aftersales ervice will be provided through their tollfree base service network located within 100 KM from the project site. The Solar Street light manufacturer should have own NABL accredieted laborotory. The following test reports must be submitted for the technical acceptance of the products.1.LM 79 REPORT (Third party NABL lab only) , 2. IK 08 (Report of Third party NABL lab only for any wattage of AIO solar light ) , 3. IP 65 (Report of Third party NABL lab only , 4. Wind load test report of AIO Street light having 180 Wp or more capacity Solar Mono Panel suitable for 180 KM/Hr wind Speed.The AIO solar street light must complies to the following :1. EN50530 – MPPT Efficiency , 2.. IEC61547 , 3. IEC61000-3-2 – EMC , 4. IEC 60598-2-3 ,5. IEC 62109-1, ( The necessary test reports of third party NABL lab against the above must be submitted for any wattage of AIO Solar street lights for acceptance of product/TDS approval prior to start of the work. All the test reports must be in the name of solar lighting company )Make- (Philips/Panasonic/Wipro only ) |
| 139 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge20mm dia C-PVC pipe |
| 140 | 25mm dia PVC pipe |
| 141 | 40mm dia C-PVC pipe |
| 142 | 50mm dia C - PVC pipe |
| 143 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.(Jaquar make/ Plaza Make/ Cera make/ Hindwere Make)15mm dia CP angle stop cock(FLR-ACR-5053N) |
| 144 | 15mm CP Extension piece |
| 145 | 125mm CP grating |
| 146 | 15mm size C.P. flange |
| 147 | Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) pure chill 120 PSS UV of size 750 x 570 x 1350mm hight with water storage capacity 120 liter's along with 3 noa of faucets 2 for cold water and 1 for normal water including a flow of 1.5 ltr per munite etc all complete as per approved drawing , specification and direction of the Engineer in chargeAqua guard pure Chill 120 PSS UV |
| 148 | RAIN WATER HARVESTING SYSTEM(PIT)(2 nos)Earth work in hard soil or gravelly soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge. |
| 149 | Supplying all materials, labour, T&P and providing cement concrete (1:4:8) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 150 | Supplying all materials, labour, T&P and providing brick work with Fly ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:6) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 151 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork with cement punning and bitumen painting over top of wall including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 152 | Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 153 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeR.C.C floor and roof slabs, landings, balconies, projecting sunshades and |
| 154 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor |
| 155 | Supplying all materials, labour, T&P and providing cement concrete (1:1½:3)with 12mm size hard broken granite chips including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floorSlab |
| 156 | providing and filling filter media40mm Boulder- |
| 157 | 20mm washed gravel-- |
| 158 | Course sand- |
| 159 | Providing fitting & fixing M.S.grill cover over the harvesty pindi |
| 160 | Sinking of tube well(200) for PITLabour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore onlyDrilling of 200mm dia bore00 mtr to 25mtr |
| 161 | Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials.200mm dia PVC pipe |
| 162 | cost of 200mm pvc pipe |
| 163 | Cutting slot in casing pipe for recharge of rain water |
| 164 | labour for packing gravel outside the tube well |
| 165 | Cost of washed gravel Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 7 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender