Tender For Repairing Of 40 Hp Pump Set At Undasa Pump House.
Tender Value
4.46 Lakhs
Estimated cost
Bid Submission
28 Oct 2026
13 days left
EMD
8950
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ujjain → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repairing Of 40 Hp Pump Set At Undasa Pump House.
BOQ
| Sl. No. | Item Description |
| 1 | Providng & Repairing of 40 HP jyoti make 30 mtr head, 1470 RPM 64 LPS discharge pump set installed at Basant vihar pump house (pump unit) |
| 2 | Complete dismantling of pipe fittings after repairing with motor pump alignment trail testing etc. |
| 3 | Providing & fixing of hardware materials including nut, bolt, packing, rubber sheet, gland etc complete. |
| 4 | Providing & fixing of G.M. Long bush. |
| 5 | Providing & fixing of C.I. gland plate & bush. |
| 6 | Providing & fixing of check ring. |
| 7 | Providing & fixing cooling water pipe. |
| 8 | Providing & changing of coupling pulley L-90 rubber star tight fit with pump & motor Couling. |
| 9 | Providing & fixing of bearing as per size & sample. |
| 10 | Providing & complete servicing of pump chamber fully movement of impeller unit with as per required fitting including check nut, bolt, washer, oil paper etc complete. |
| 11 | Providing & making of bearing sheet both side of pump & required lathe machine lathe work complete. |
| 12 | Providing and fixing of new heavy duty compressor with lathe for pumps 150 mm dia foot valve i/c complete opening, fitting, replacing as per required G.I., nut, bolt, washer etc complete. |
| 13 | Complete rewinding and Repairing of 40 HP three phase, 440 volt, 50 Hz, 1470 RPM 2 set jyoti make induction motor having following works. (Motor unit) |
| 14 | Dismantling of burnt winding wires from slots cleaning and straightening of slots. |
| 15 | Complete rewinding of motor by using super enmamlled copper wire with F-class insulation materials and varnishing, drying by heating process. |
| 16 | Providing and fitting ball bearing as per sample & size of any standard make. |
| 17 | Providing and fitting of Terinal plate. |
| 18 | Providing and fitting of C.I. housing sleeve. |
| 19 | Making of bearing seat by welding & lathe machine turning & knurling, polishing on motor shaft. |
| 20 | Complete reinsulation for taking out of motor for foundation sepration of motor and pump for base plate and opening the motor taken out rotor from stator cleaning and drcarborizing rotor and stator and stator 3 phase winding reinsulation, heating etc. complete. |
| 21 | Providing and making of diametrically balancing rotor assembly. |
| 22 | Providing & fixing of C.I. motor cooling fan. |
| 23 | Complete rewinding of motor for plate checking of horizontal and vertical alignment of motor shaft, coupling with pump and trial testing of horizontal and vertical alignment, grease etc complete. |
| 24 | Providing & complete repairing of 40 HP ATS starter for 2 nos, set at Indira nagar pump house i/c labour charge for fitting with burnet equipment & changing burnet wiring & lugn etc. as per required complete work. |
| 25 | Providing for complete replacing for complete repairing of 250/300 amp., 415 volt 50 Hz molded case circuit breaker for standard MCCB for main power supply equipment. |
| 26 | M.L.-4 L & T make contactor 50 hr., 415 volt. |
| 27 | M.L. -4 L & T make contactor 50 hr., 415 volt. |
| 28 | M.L. -1.5 L & T make contactor 50 hr., 415 volt. |
| 29 | Volt meter 0-500 volt for starter. |
| 30 | Digital amp. meter (0-150 amp) for starter. |
| 31 | Current transformer coil range 50-100/5 amp. for starter. |
| 32 | Relay unit range 0-80 amp. |
| 33 | Selector switch for volt meter. |
| 34 | Selector switch for amp meter. |
| 35 | LED indicator lamp unit for starter. |
| 36 | Timer assembly unit for starter. |
| 37 | On/Off switch unit for starter. |
| 38 | Taking out of auto transformer coil set dismantling replacing & re-insulation of coil set and refitting and seating as required. |
| 39 | E.H.V. transformer oil for auto transformer starter. |
| 40 | Providing & fixing of incoming & outgoing fiber connection terminal plate with complete copper nut bolt & wiser. |
| 41 | Complete overhauling of panel & starter for using power circuit wiring & control circuit wiring as per required wire & lugs etc. rail & testing on load complete. |
| 42 | Loading & unloading complete job repairing for site to work shop & work shop to site. |
| 43 | Providing and fully rewinding of ATS both coil set i/c dismantling of ATS coil stamping after fitting fully varnishing, taping and setting of appearing range of connection rail testing on full load at site. |
| 44 | Providing and fixing of heavy duty capacitor 440 V, 15 KVAR capacitor with complete as per required work. |
| 45 | Providing & fixing of rubber mating 12 mm. thick superior quality high density as per ISI mark. |
| 46 | Labor charge for complete reparing & refitting of 150 mm dia. non return sluice valve& sluice valve i/c cutting of old damaged nut bolt, & Providing recasting finishing machining of gate of gate plate holding rod assembly as per sample & required packing complete nutl bolt for fitting on delivery pipe line at side as per following items. |
| 47 | Supply of S.S. 410 spindle rod without G.M. check nut for 150 mm dia. |
| 48 | Recasting of 150 mm dia sluice valve G.M. check nut i/c recasting, finishing, machining & threading as per sample & cost of extra material complete work. |
| 49 | Repairing of 150 mm dia. sluice valve C.I. fixture check nut catcher both side i/c welding, finishing cutting as per size of check nut. |
| 50 | Labor charge for complete reparing & refitting of 150 mm dia. sluice valve i/c cutting of old damaged nut bolt, removal of damaged galnd packing, rubber packing, providing, fixing of new by fabricated parts & greasing properly cost of nut bolt, over hanting the valve transportation of material T&P testing & making with risk cover as per requirement. |
| 51 | Providing & fixing of pressure gauge meter 0.0 to 7 or 0.0 to 10 Kg./cm² size 150 mm dia with pressure control tube, nut bolt, socket, GI nipple with GM valve 150 mm dia etc complete work. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 28, 2026
17:00 IST