Tender For Renovation Of Lab T-205, Real Time Hazordous Gas Servilence System, Technology Block, Csir-Csio, Chandigarh.
Tender Value
6.69 Lakhs
Estimated cost
Bid Submission
20 Oct 2026
11 days left
EMD
13386
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Renovation Of Lab T-205, Real Time Hazordous Gas Servilence System, Technology Block, Csir-Csio, Chandigarh.
BOQ
| Sl. No. | Item Description |
| 1 | Reinforced cement concrete work in beams, suspended floors, roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels, bands,plain window sills, staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing andreinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derivedfrom natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). |
| 2 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 3 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level inall shapes and sizes in : Cement mortar 1:4 (1 cement: 4 coarse sand) |
| 4 | Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:3 (1 cement :3 coarse sand) including 6 mm bar laying evey 3course of layer. |
| 5 | Centering and shuttering including strutting, propping etc. and removalof form for Lintels, self,beams, plinth beams, girders, bressumers andcantilevers all comlrte up to five level of building. |
| 6 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Granite stone slab of any colour and size etc. ( basic rate 250/- per sqft) |
| 7 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc.complete as per design approved by Engineer-in-Charge. Granite work |
| 8 | Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality withnecessary screws etc. complete. Godrej/Grace/Harison or equivalent make |
| 9 | Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 50mm Godrej/Grace/Harison or equivalent make |
| 10 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.Sandhu/ Grace/ Universal make |
| 11 | Providing and fixing aluminium sliding door bolts, ISi marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :250x16 mm make Classic or equivalent. |
| 12 | Providing and fixing aluminium tower bolts, ISi marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :250x10 mmmake Classic or equivalent. |
| 13 | Providing and fixing aluminium tower bolts, ISi marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :150x10 mm |
| 14 | Providing and fixing aluminium handles, ISi marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyedto required colour or shade, with necessary screws etc. complete : 125 mm make Classic or equivalent. |
| 15 | Providing and fixing aluminium handles, ISi marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :100 mm make Classic or equivalent. |
| 16 | Providing and fixing aluminium hanging floor door stopper, ISi marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper make Classic or equivalent. |
| 17 | Providing and fixing aluminium casement stays, ISi marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.make Classic or equivalent. |
| 18 | Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm |
| 19 | 12 mm cement plaster of mix :: 1:4 (1 cement : 4 fine sand) |
| 20 | 15 mm cement plaster on the rough side of single or half brick wall of mix :1:4 (1 cement: 4 fine sand) |
| 21 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer Asian paint / Dulux/ Nerolac and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre including scraping if any area. |
| 22 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer Birla wallcare/Asian /JK wall putty, over the plastered wall surface, of |
| 23 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer Asian paint / Dulux/ Nerolac including applying additional coats wherever required to achieve even shade and colour Old work (one or more coats) including scraping if any area. |
| 24 | Painting with synthetic enamel paint of approved brand and manufactureAsian paint / Dulux/ Nerolac of required colour to give an even shade one or more coat |
| 25 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.With cement mortar 1:4 (1 cement : 4 fine sand) |
| 26 | Dismantling tile work in floors and roofs laid in cement mortar, including stacking material within CSIO . For thickness of tiles 10 mm to 25 mm |
| 27 | Cutting chases in brick masonry walls for following diameter sand cast iron/centrifugally cast (spun) iron pipes and making good the same with cementconcrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5mm nominal size), including necessary plaster and pointing in cementmortar 1:4 (1 cement : 4 coarse sand) |
| 28 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portion Powder coated aluminium (minimumthickness of powder coating 50 micron)inclung sliding aluminium and stainless steel screw |
| 29 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimumthickness of powder coating 50 micron)inclung sliding aluminium and stainless steel screw |
| 30 | Providing and fixing 11 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides |
| 31 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm( including dismentling existing if any |
| 32 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5.0 mm thickness (weight not less than 10kg/sqm |
| 33 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 25 mm depth 25 mm width |
| 34 | Providing fixing vertical blinds vista or equivalent make design as per direction of engineer inchrage including dismentling existing if any. |
| 35 | Providing & fixing aluminum composite paneling 3mm thick on wall, partition, facia ,column self etc etc at required place as per direction of Engineer in-charge. The ACP be exterior grade of any metallic colour, Alstone, or equivalent The fixing with screw, desh fasteners etc. The size, c/c spacing of ACP be as per the site adjustment but must be uniform spacing. The joints to be filled with silicon of DOW coming /wacker make. |
| 36 | Disposal of building rubbish / malba / similar unserviceable, dismantledor waste materials by mechanical means, including loading, transporting,unloading to approved municipal dumping ground or as approved byEngineer-in-charge, beyond CSIO initial lead, for all leads including alllifts involved. |
| 37 | Electrical Disconnection and Dismantling of some old electrical acessories like MCBs, MCCB, switchboar,power/light plug, UPVC Trunking , cable size upto 35 sqmm length 20m Approx. and shifting of material from site to store. as required and directed by Engineer-In-Charge.Note:- Before Quoting the rates, please visit the site foe assessment of the work. |
| 38 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group-C(Note- Moduler box used for switches should have 25% extra space as required) |
| 39 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group-C |
| 40 | Supplying and drawing 3 x 1.5 sq.mm of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit asrequired.) |
| 41 | Wiring for circuit/ submain wiring alongwith earth wire with the 2X2.5 sq mm + 1X2.5 sq mm earth wire of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (Note- Minimum size of 25mm medium class PVC conduit must be used) |
| 42 | Supplying and drawing 3 x 2.5 sq. mm of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 43 | Wiring for circuit/ submain wiring alongwith earth wire with the 2X4 sq mm + 1X4 sq mm earth wire of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (Note- Minimum size of 25mm medium class PVC conduit must be used ) |
| 44 | Supplying and fixing 3 Module (100mmX75mm) modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 45 | Supplying and fixing 6 Module (200mmX75mm) modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 46 | Supplying and fixing 12 Module (200mmX150mm) modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 47 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 48 | Supplying and fixing 5/6 A modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (Note: Suitable for fixing on PVC modular box for PVC trunking) |
| 49 | Supplying and fixing 15/16 A modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 50 | Supplying and fixing modular 3 pin 5/6 A socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (Note: Suitable for fixing on PVC modular box for PVC trunking) |
| 51 | Supplying and fixing modular 6 pin 15/16 A socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 52 | Supplying and fixing of phenolic laminated sheet of 3 mm thick , ISI marked with cutting etc. anyone of make Heylem/Super Heylem. |
| 53 | Fixing of modular 3 pin 5/6 A socket outlet with switch including modular plate & switch box/conversation frame and connections etc. as required. (Note: Suitable for fixing on PVC modular box for PVC trunking) |
| 54 | LED Panel light 2x2 ft. (System lumen efficacy ≥105<120 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) 36 watt |
| 55 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 56 | Supplying and fixing 5 A to 32 A rating, 240/415 V,10 kA,\\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 57 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA inthe existing MCB DB complete with connections, testing and commissioning etc. as required. 63A |
| 58 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 59 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 60 | Supply of Metallic Body Exhaust Fan of size 300 mm sweep, with G.I. sheet louver shutter, Grey in color, RPM: 900-950, four number blades, Air delivery (minimum) 1145 m3/h, low noise level, suitable for 230V, 50 Hz, single phase AC Supply, complete as required. |
| 61 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450mm sweep |
| 62 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 63 | Supplying and fixing of 25mm size of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 64 | Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. |
| 65 | Supplying and fixing of u-PVC adaptable trunking system of size 100mm X 50mm complete with trunking cover,end cap etc. for housing the electrical modular box for fixing modular switch sockets, telephone socket etc, on the wall/tables/pillars etc. as required. |
| 66 | Supply and fixing of PVC 6 module conversation frame for CMS trunking with cover plate and blanking plate suitable for fixing in 100mmx50mm DLP U-PVC trunking for fixing the modular switch and socket 5amp./15amp. Complete as required at site. |
| 67 | Supply and fixing of RJ45 CAT6 Computer Jack with PVC modular box/conversation frame, base and cover plate suitable for fixing in 100mm x 50mm U-PVC trunking complete as required at site. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysOct 29, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender