Tender For The Work Of Strengthening And Improvement Of Water Supply Distribution Network In The Jurisdiction Of Jaipur Nagar Nigam Greater Under Amrut 2.0 District- Jaipur
Tender Value
42.13 Crore
Estimated cost
Bid Submission
03 Nov 2026
26 days left
EMD
84.26 Lakhs
Bank guarantee accepted
Document Fee
25000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jaipur → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for The Work Of Strengthening And Improvement Of Water Supply Distribution Network In The Jurisdiction Of Jaipur Nagar Nigam Greater Under Amrut 2.0 District- Jaipur
BOQ
| Sl. No. | Item Description |
| 1 | Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS:8329-2000 (amended upto date), with internal cement mortar lining for potable water with rubber ring (EPDM/SBR) joints as per IS: 5382-1985 (excluding special accessories) complete including all material, labour, hydraulic testing and commissioning as per Technical Specifications and as per direction of Engineer.Note : E/w to be measured and paid separately. |
| 2 | 250 mm |
| 3 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and thenreturning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.:All kinds of soil |
| 4 | Depth upto 1.5 m |
| 5 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and thenreturning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and stacking serviceable material for measurements and disposal of unserviceable material as directed, with in a lead of 50 Mtr. including all safety provisions required |
| 6 | In ordinary rock. (10 %) |
| 7 | Dismantling of flexible pavement for pipe line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench tobe made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re_x0002_handling of material/earth to complete the tasks per technical specification and scope of work.. |
| 8 | Bituminous courses |
| 9 | Granular courses |
| 10 | Dismantling of cement concrete pavement for pipe line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. |
| 11 | Barricading work |
| 12 | Barricading with Sal ballies as per designincluding tying with vertical post by coconutstrings including digging out holes in all types of soil complete in all respect with two horizontal members height 1.2 m upto 1.5m above ground level and vertical supports upto 2.5 centre and upto 3 days period including removal and cleaning the site complete in all respect & including dressing of sides and providing retro reflective tapes for traffic safety as per direction of Engineer-in charge in all types of soil. |
| 13 | Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Double Acting Kinetic Air Valve with isolating Sluice Valve of approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amended up to date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float -Stainless Steel AISI 304 / IS: 3444 , Float Guide_x0002_HBT1.HP Orifice- HTB2/ SS,Body seat ring - Leaded tin bronze/ SS .Seal ring and face ring - PDM/NBR ,Ends flanged according to IS 6418,Fastners - CS, Epoxy paint inside outside of food grade safe for drinking water ,Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. |
| 14 | Class PN 1.0 |
| 15 | 50 mm dia |
| 16 | Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves straight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - AISI- 410 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel Insertion rubber of black EPDM 6mm thick .Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as perdirection of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 17 | Manually operated class PN 1.0 |
| 18 | 250 mm HW |
| 19 | Providing and fixing of flanged/ plain ended MS pipe made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete (excluding flanged jointing wherever required) including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer. |
| 20 | MS pipe upto 600mm dia (with minimum 5mm thickness sheet) |
| 21 | Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer. |
| 22 | 250 mm dia. |
| 23 | Construction of RCC Air valve chamber for different type of valves including earthwork excavation, 100mm PCC M15 as levelling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast slabs, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as per direction of Engineer-in-Charge. |
| 24 | For Class-A loading |
| 25 | Air valve chamber of size0.9m x1m x1.71mfor air valve size-from 50 mm-to-80mm |
| 26 | Construction of RCC Sluice valve chamber for different type of valves including earthwork excavation, 100mm PCC M15 as levelling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast slabs, plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as per direction of Engineer-in-Charge. |
| 27 | For Class-A loading |
| 28 | Sluice valve chamber of size1.26m x1.185m x1.82mfor pipe size-from 200-to-300mm |
| 29 | Carriage of Materials by mechanical transport including loading,unloading and stacking ::Sand, bazri, ballast, kankar- Lead upto 5 Km |
| 30 | Construction of RCC (Flat Slab Rectangular) Clear Water Reservoir of following capacity as per Scope of work and Technical specification, consisting of the following main activities: |
| 31 | a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Flat/Slab, rectangular .Staircase c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill.d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall.e) Successful hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the roof Slab.g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure. |
| 32 | h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type).i) Providing and fixing MS ladder from ground to top slab.j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide.k) Providing and fixing of 150mm wide water bar for the construction joints in the container.l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir.m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. |
| 33 | Rates for RCC Partially Underground type clear water reservoir SBC 7 MT/sqm, SEISMIC ZONE-2 & 3. |
| 34 | 2400 KL capacity for Tilak Nagar Zone |
| 35 | Providing, lowering, laying in trenches, aligning, fixing in position and double flanged (welded) centrifugally (spun) Ductile iron ISI marked K-9 grade pipes as per IS:8329-2000 (amended upto date), (including jointing and jointing material) complete including all material, labour, hydraulic testing and commissioning as per Technical Specifications and as per direction of Engineer.Note : E/w to be measured and paid separately. |
| 36 | 450 mm |
| 37 | Providing, lowering, aligning & fixing in position DI D/F Plunger Type Flow Control Valve of approved make of following Pressure rating & dia complete and of following specifications: Body- Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or EN-JS 1030, Plunger/ Piston - Stainless steel AISI- 304/ Gr 1.4301, Piston Guides- Bronze Welded Overlay / SS Shaft/Crank/Spindle- Stainless steel AISI- 410/ Gr 1.4021 Body Seat Ring- Stainless steel AISI- 316/304/ Bronze IS:318-LTB2 ,Seal ( O- ring / Quad ring)- EPDM/ NBR, Bearing Bush - Bronze IS:318-LTB2,Slotted cylinder / Strainer / Diffuser- AISI- 420/ 304,Nut- Bolts - SS, Face to Face- as per ANSI B 16.1/ EN 558-1 and Flange ends should be as per ANSI B-16.5, Class 150 and Class 300/ EN-1092-2. Insertion rubber of black EPDM 6mm thick ,Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied both inside and outside . Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning as per Technical Specification & as per direction of Engineer-In- Charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 38 | Inlet Pipe from Bisalpur |
| 39 | Plunger Type Flow Control Valve |
| 40 | 250 mm dia |
| 41 | SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) ,Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement of IEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC -50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, if required, and all materials required for making connection etc. complete in all respect as per technical specification and direction of Engineer In-Charge. Note: Rates are exclusive of tail piece / dismantling joints and earth work. |
| 42 | Inlet Pipe |
| 43 | EFM 250 mm |
| 44 | Outlet pipe |
| 45 | EFM 600 mm |
| 46 | Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves straight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - AISI- 410 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel Insertion rubber of black EPDM 6mm thick .Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 47 | Manually operated class PN 1.0 |
| 48 | Inlet Pipe at Bisalpur line |
| 49 | 250 mm HW |
| 50 | Delivery Pipe from CWR |
| 51 | Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.6 |
| 52 | 450 mm dia |
| 53 | Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer. |
| 54 | 250 mm dia PN-1.0 |
| 55 | 450 mm dia PN-1.0 |
| 56 | Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) Swing type Non Return Valve of approved make of following Pressure rating & dia complete, generally confirming to IS: 5312 (part -1)/ 2004 (amended up to date) and of following specifications: Body, Bonnet & disc of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG- 400/12 as per IS 1865 or equivalent grade as per IS :3896-part2- 1985 and subsequent revisions, Face to face dimensions as per IS 5312 (part -1):2004 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body, cover and disc inside and outside . Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 410, Hinge SS AISI 316/410 ,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR \\"O \\"ring seal Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earthwork. |
| 57 | Class PN 1.6 |
| 58 | 450 mm dia |
| 59 | Providing and making flanged joints to double flanged C.I./ D.I. pipes and specials such as tees, bends, tapers, caps etc. at all level/depths within trenches complete including all material i.e. rubberinsertions, bolts & nuts etc, labour, testing of joint, commissioning along with pipe line as per Technical Specifications and as perdirection of Engineer. |
| 60 | 450 mm dia |
| 61 | 600 mm dia |
| 62 | Providing and fixing of flanged/ plain ended MS pipe made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete (excluding flanged jointing wherever required) including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer. |
| 63 | MS pipe upto 600mm dia (with minimum 5mm thickness sheet) |
| 64 | MS pipe Avove 600mm dia (with minimum 6.3 mm thickness sheet) |
| 65 | Construction of RCC Sluice valve chamber for different type of valves including earthwork excavation, 100mm PCC M15 as levelling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast slabs, plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as per direction of Engineer-in-Charge. |
| 66 | For in-campus Valve Chambers |
| 67 | Sluice valve chamber of size 1.61m x1.75m x2.85mfor pipe size-from 500-to-700mm (Shall be made as per GA Drawing and field Requirement) |
| 68 | Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcement for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. M20 grade Nominal Mix / Design Mix |
| 69 | Column |
| 70 | Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having lopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix |
| 71 | ( lintel doors , window and ventilation ) |
| 72 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc. of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc. |
| 73 | ( lintel doors , window and ventilation ) |
| 74 | Lintel Beam, Lintel Chhaja, Roof Beam, Slab area, Total |
| 75 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc. of formwork for upto floor five level for_ Columns, pillars, posts and struts etc. |
| 76 | Column |
| 77 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level.(Original producers who manufactura billet directly from iron ores and roll the billets to produce steel conforming to IS:786)Thermo-mechanically Treated bars (Tata, SAIL) |
| 78 | Total |
| 79 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : 5.2.1 Cement mortar 1 : 4 (1 cement : 4 coarse sand) Cum. 5196.00 |
| 80 | long wall, Deduction-Door -MD, W, ventilation, Total |
| 81 | Half brick masonry in Superstructure , above plinth level upto floor V level using bricks of designation 75; 5.8.2 Cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 82 | middle walls, Dedection , door-D1, D2, Total |
| 83 | Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades ceramic glazed vitrified tiles with water absortion less than or equal to 0.08% confirming to IS:13753 & IS : 15622 on walls, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar).Size 600mm x 1200mm |
| 84 | Grading roof water proofing treatment with water profing compound :Cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). |
| 85 | Providing batta (gola) 75 mm x 75 mm in cement concrete (1 : 2 : 4) including finishing with cement mortar 1 : 3 as per standard design. |
| 86 | Providing and fixing precast cement concrete coping 1 : 2 : 4 mix 50 mm thick complete as per specification : '--- |
| 87 | Plaster on new surface on walls in cement sand mortar 1:4 including racking of joint etc. complete fine finish : 20 mm thick |
| 88 | 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand).; Celling plaster |
| 89 | Making grooves as per design in plaster 10 mm to 20 mm wide.; (add; 20 % R.M. of plaster work.) |
| 90 | Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete New Plastered Surface (three or more coats) |
| 91 | Finishing walls with textured exterior paint of required shade as per approved colour complete as per manufacturers specifications including primer coat and protecting coat including scaffolding and safety provision. Trowel Finish av. thickness 2000 to 2500 microns. |
| 92 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding:Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. |
| 93 | Providing & fixing door, window, chowkhats and other frames, including antitermite treatment, M.S. flat, hold fasts of size 250 x 40 x 3mm fixed with M.S. bolt 5mm dia 50mm long duly embedded in cement concrete M-15 grade : Nigeria teak wood Grade - I. |
| 94 | Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure 'A' : 35 mm thick, commercial Veneer Both side. |
| 95 | Extra for providing other type of fittings as mention in annexure A ( as approved by EI) : Stainless steel fittings. (for door leaf shuter) |
| 96 | Extra for providing external lipping with 2nd class teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) ; for door leaf shutt |
| 97 | Providing and fixing bright finished Mortice lock of approved make Godrej or equivalent with pair of CP handles for doors with necessary screws etc complete (Best make of approved quality) as per direction of Engineer-in-charge. |
| 98 | Providing & Fixing mica of approved make for inner/outer side of shutters with fevicol & nails complete as per approved by engineer in charge.0.8mm thick mica |
| 99 | 9.19 Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038- 1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required |
| 100 | Windows side hung /Ventilators top or centre hung (openable) |
| 101 | Providing brass handles/peg stays and fittings in place of oxidized fitting Sqm. 5% |
| 102 | 5mm thick plain glass instead of 4mm thick plain glass Sqm. 95.00 |
| 103 | Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. Sqm. 617.00 |
| 104 | 1.1 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 105 | Short point (up to 3 mtr.) |
| 106 | Medium point (up to 6 mtr.) |
| 107 | Long point (up to 10 mtr.) |
| 108 | 3 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexiblecopper earth conductor 1.1 kV grade(IS:694) inrecessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thickwith earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket,Modular face plate with grid plate, screws, making connections, testingetc. as required. For specification of copper Conductor, PhenolicLaminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E- 05 & E - 07 For additional technical p |
| 109 | On board |
| 110 | S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 111 | 20 mm |
| 112 | 25 mm |
| 113 | 4.2 Supplying and drawing coaxial cable 75 ohm impedance with foam PE insulated solid bare copper inner conductor, and Ist outer conductor of bonded alum. tape and second outer conductor of alum. alloy braid in existing surface or recessed conduit/casing capping including making connections as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 114 | Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TECspecification GR / WIR/06-03 March 2002 in existing surface or recessed conduit/casing capping. including ferruling on each pair forIdentification etc. as required. For additional technical parameters ofproduct / work refer Annexure 'A' attached with this BSR;4.3.4 4 pair |
| 115 | P & F 1.2 mm thick G. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR ;5.1.1 1.2 mm thick M. S. Sheet boxes ; |
| 116 | 100mm x 100mm x 60mm |
| 117 | 200mm x 250mm x 75mm |
| 118 | P & F 1.2mm thick M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 119 | P & F 1.00mm thick M.S. Recessed concealed box, round of size 150 mm dia, depth 100 mm complete as required. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 120 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947- 2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 121 | Single pole MCB (With B/C curve tripping Characteristics) |
| 122 | 6 A to 32 A rating |
| 123 | Providing & Fixing of 240/415 V isolator ISI marked IS:13947- III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage, true contact indication, Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting, minimum phase termination capacity of 35sq.mm. IP 20 contact protection and fitted in existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR;6.2.3 Four pole Isolator; 63 A rating |
| 124 | Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 125 | Metal door (single phase) IK-09 and IP-43 with Metal end box |
| 126 | 6 Way (6+2) |
| 127 | Providing & Fixing of ISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captivescrews including making connection testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR |
| 128 | Providing & Fixing of ISI marked (IS:1258) batten/angle lamp holder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 129 | Providing & Fixing of modular type lockable feature socket duly made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including all as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 130 | 6/16 A shuttered socket |
| 131 | 7.29 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printed made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captivescrews & silver alloy contact tip with IP-20 rating , including all as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work referAnnexure 'A' attached with this BSR ;7.29.1 5 step fan regulator 2 Module 360 dgree rotating |
| 132 | Providing & Fixing of following modular accessories as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including all as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 133 | Modular MCB 6 A to 32 A SP |
| 134 | Providing & Fixing of following size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 135 | 3 Module Each 86.0 |
| 136 | 6 Module Each 114.0 |
| 137 | 8 Module Each 155.0 |
| 138 | 12 Module Each 214.0 |
| 139 | Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification of Wiring accessories refer Chapter E - 07 related item & For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 140 | 11.3 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured Copper cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity >99.7 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 141 | 10.0 Sq. mm, 4 core 4 core |
| 142 | Providing & Fixing of 1200 mm sweep BLDC technology power saving ceiling fan which can withstand on votage fluctuations from 140 volts to 240 volts ,power factor not less then 0.9 , service value (CMM/W) minimun 6.85 , air delivery minimun 220 CMM, speed minimum 330 RPM ( tolerance as per IS:374 2019 ) THD less then 10% and complete with down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steel pipe up to 80 cm , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 15.4.1 Without Remote |
| 143 | 15.12 Providing & Fixing of Heavy duty capacitor start, copper wound Double ball bearing 900/1400 RPM single phase Exhaust fan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 300 mm sweep(900/1400 RPM) |
| 144 | Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / Sqaure SMD Mid Power LED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 145 | 17.3.1 Recessed Mounting ;Minimum lumen output 650 lm |
| 146 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required.Gr I |
| 147 | 3x 1.5 sq.mm |
| 148 | 2 x 2.5 sq. mm. + 1x1.5sqmm ( All light and power Ckt) |
| 149 | 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. (AC Ckt) |
| 150 | 4 x 10 sq.mm (Sub main) |
| 151 | 1 x 6 sq.mm (With sub main ) |
| 152 | Providing, installation, testing and commissioning of Submerged Centrifugal Pump sets with motor 4 pole synchronised speed of 1500 rpm ( water immersed, dry air filled, lass \\"F\\" insulated TEWC motor integrally mounted on volute casing pump sets for drinking water ) 3 phase, 415 volt +/- 10%, along with suitable foundation/installation device and with 10 mtr cable, material of construction of impeller SS, casing (volute) CI, wearing ring SS, etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribedduty conditions mentioned in TD. |
| 153 | 90 KW |
| 154 | SITC of Variable Frequency Drives with panel supplied by manufacturer conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, display of electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus. |
| 155 | 90 KW |
| 156 | Replacement of Existing Pumping machinery |
| 157 | Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casting pumps with motor as per IS 12615-2011 or amended up to date, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specification |
| 158 | Tilak Nagar Zone-2 |
| 159 | Discharge 71 to 80 LPS and head 41 to 50 M |
| 160 | Bapu Nagar |
| 161 | Discharge 41 t0 50 LPS and head 31 to 40 M |
| 162 | Discharge 121 to 140 LPS and head 41 to 50 M |
| 163 | Gandhi Nagar |
| 164 | Discharge 161 to 180 LPS and head 31 to 40 M |
| 165 | Discharge 41 t0 50 LPS and head 31 to 40 M |
| 166 | Jyoti Nagar |
| 167 | Discharge 51 to 60 LPS and head 41 to 50 M |
| 168 | Discharge 81 to 90 LPS and head 31 to 40 M |
| 169 | Discharge 101 to 120 LPS and head 31 to 40 M |
| 170 | Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS AISI 316/410 Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in_x0002_charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. (For Replacement outside pumphouse_ Annex-E-16(2) |
| 171 | Manually operated class PN 1.6 |
| 172 | 200 mm dia |
| 173 | 300 mm dia |
| 174 | 450 mm dia |
| 175 | 500 mm dia |
| 176 | Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.6 |
| 177 | 200 mm dia |
| 178 | 250 mm dia |
| 179 | 300 mm dia |
| 180 | 450 mm dia |
| 181 | 500 mm dia |
| 182 | Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves of approved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amended up to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 410/316 & shaft bearings- bronze/ PTET or Teflon with EPDM/NBR \\"O \\"ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 183 | Class PN 1.0, Motorised Operated |
| 184 | 200 mm dia |
| 185 | 250 mm dia |
| 186 | 300 mm dia |
| 187 | Providing, lowering, aligning, fixing in position in pipe line, CI double flanged Dual plate check valve of approved make of following Pressure rating & dia complete, as per API: 594/ API: 598 and of following specifications: Body & Cover of Grey cast iron of IS:210/ FG200 , Disc / plates - Cast steel ,Disc seal ring of EPDM/ NBR (food grade quality) ,Body seat of SS ,Face to face dimensions as per API: 594 ,Flanges Drilled as per IS:1538. Epoxy (Non-Toxic & suitable for drinking water) applied on body & cover inside and outside . Shaft/Stop Pin of SS- AISI- 304/410 , Hinge SS AISI 316/304 / CS ,Spring SS AISI 316/304 , Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR \\"O \\"ring seal.Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) ,Insertion rubber of black EPDM 6mm thick . Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 188 | Class PN 1.0 |
| 189 | 200 mm dia |
| 190 | 250 mm dia |
| 191 | 300 mm dia |
| 192 | SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/Chlorinated) , Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU), Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement of IEC 60529, Accuracy : ± 0.5 % M.V.-velocity 0.3 to 10 m/s, transmitter/ signal convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC -50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, if required, and all materials required for making connection etc. complete in all respect as per technical specification and direction of Engineer In-Charge. Note: Rates are exclusive of tail piece / dismantling joints and earth work. (Annex-E-16(2) |
| 193 | EFM 300 mm |
| 194 | EFM 450 mm |
| 195 | EFM 500 mm |
| 196 | Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer. |
| 197 | 200 mm dia PN-1.0 |
| 198 | Providing, installation, testing and commissioning of following Stain less steel AISI 304 Expansion bellows of 10/16 bar rating with tie rods as per technical specifications and layout drawings including jointing material like nuts, bolts, rubber gaskets etc. complete in all respect as per technical specification and as per direction of Engineer. |
| 199 | 250 mm dia. |
| 200 | 300 mm dia. |
| 201 | 450 mm dia. |
| 202 | 500 mm dia. |
| 203 | Providing and fixing of flanged/ plain ended MS specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete (excluding flanged jointing wherever required) including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and direction of Engineer. |
| 204 | MS pipe upto 600mm dia (with minimum 5mm thickness sheet) |
| 205 | Providing, installation, testing and commissioning of submersible dewatering pump set conforming to relevant IS codes and as per scope of work and Technical Specifications, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft, impeller, pump and motor body. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard. The pump set shall be suitable for direct coupling, with suitable suction strainer etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. |
| 206 | 2.2 KW (3.0 HP) |
| 207 | Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg. including all jointing material as per specification with safety cover. |
| 208 | SITC of star rated Aluminium wound distribution Transformer of following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & as per BEE star - 1 & BIS approved as per IS 2026- 1977 & losses as defined as per 2014 (Fourth Revision) Level-1 . including standard accessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C upto 200 KVA & 40-45 degree C for above 200 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer complete in all respect . The Transformer shall be subjected to routine factory tests (as per IS:2026 and IS:1180) including testing from CTL of discom before charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, (CTL testing charges and Electrical Inspection charges shall be reimbursed by the department to the contractor). All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 209 | 315 KVA with Off -LTC (+5% to - 10% @ 2.5%) |
| 210 | 400 KVA with Off -LTC (+5% to - 10% @ 2.5%) |
| 211 | Supply, installation, testing & Commissioning of Copper wound distribution Transformer of following rating and % Impedance, 11/0.433KV Delta-Star Connected, Vector Group Dyn 11, ONAN Cooled losses as per IS 1180 part I 2014 (Fourth Revision) Level-1, with boltless core design including standard accessories like conservator with prismatic oil level gauge , silica gel breather, Bucholz relay, pressed steel radiator fins, Radiator Valve(above 800 Kva) Suitable size HT cable box, LT cable box with Busbar connection for outgoing cables, Off -LTC (+/- 2.5%, +/- 5% to - 7.5% ), temperature rise of 40 degree C in oil / 45 degree C in winding , drain valve, Air release device, Dial type Oil & Winding Temperature gauge with alarm & trip contacts, first filling of transformer oil as per IS :335-1953 , Epoxy primer and PU based paint as Top coat, Unidirectional rollers for rating upto 800 kva & bi- directionalabove 800 Kva rollers with locking arrangement etc. as required. The Transformer shall be subjected to routine factory tests (as per IS:2026 and IS:1180) including Temperature rise test in OEM's own lab shall be witnessed by Department engineer Physically. Transformer shall be tested from CTL of discom before charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, (CTL testing charges and Electrical Inspection charges shall be reimbursed by the department to the contractor)Following tests shall be carried out on each transformer at site by OEM enginer in presence of department authorised representative:- a) Ratio test on each tapping.b) Resistance of windings at principal and all tapings.c) Insulation resistance of the winding between HV to earth / HV to LV / LV to earth.d) Vector group test.e) Magnetic Balance test. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work, refer Annexure \\"A\\" attached with this BSR . |
| 212 | 630 KVA with % Impedance 4.5 |
| 213 | Supply & Installation of D.P. Structure With AIR BREAK SWITCH having following specifications A, B, C, D, E. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . A) Double pole structure on 2 no ISMB ( I beam ) of size 150 x 75 mm, 10 mtr length using 7 no MS channel each of size 100 mm x 50 mm x 2500 mm complete in all respect with nuts, springs washers, clamps as required. B) Off load type gang operated 3-pole vertical flute type switch suitable for 11KV ; 400A ,3-ø, central post rotating double break isolator complete with MS hardware , copper moving & fixed contact ,assembly of 9 nos pin insulator ,GI pipe of suitable length for operation. C) 3nos Vertical / Horizontal mounted 11kv horn gap fuse set /drop out 11kv barrel fuses mounted on 6no pin insulators D) 3 piece non linear resistor type. lighting arrestor of approved make suitable for 3 wire, 11kv Overhead line with rated voltage of 9kv rms & nominal discharge current rating of 5 ka & complete with galvanized clamping arrangement GI bolts, nuts, washer etc as required. E) 3 no 11kv ACSR conductors mounted on pin type insularors as required. 6.GENERAL:The go shall be operated by hand operated liver properly earthed with provision for locking mounted at 3’ |
| 214 | SITC of HT metering cubical panel as approved By DISCOMs fabricated out of 18 SWG CRCA sheet steel in two compartment & MS angle of size 60mmX 6mm having provision for Following: (i)Provision for fixing Trivector / Import - Export Meter (To be supplied by DISCOMs) (ii)Provision for fixing of combined CT PT Set with Copper strip for Connection (To be supplied by DISCOMs), (iii)Test terminal Block, (iv) 6mm thick Bakelite sheet on all sides, (V) 3/6 corex 1.5 / 2.5 Sq.mm copper cable for interconnections, etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 215 | SITC of 11kV 630 Amps 21KA for 3 Sec. SF6 insulated, outdoor duty (IP54) , Extensible / Non extensible type Ring main unit (RMU) manually operated in combination of VCB modules and Load Break switch consisting of Copper busbar in SF6 insulated 304 (Non-Ferrite Non-Magnetic Grade) stainless steel enclosure of thickness 2.5mm with manometer. The HV switchgear and control gear should be confirming to IEC-62271-100, IEC-62271-200-2003 & IEC-60694-1996. The RMU should be internal arc tested for 21KA for 1Second with IAC-AFL classification for gas tank. Vacum Interrupter of VCB should be RMU Manufacturer’s own make. Each feeder of RMU should have voltage presence indicator. . and compring of followings:- 1 no. microprocessor based Self powered numerical relay with over Current/ earth fault & short circuit protection with each VCB feeder. - 3 Nos. Protection CT shall be of Burden 2.5VA, ratio 50/1A, Class of Accuracy class 5P10 for O/C and E/F protection for each VCB.- 1 No. Manometer for each tank,- 1 nos. Fault Passage indicator,-Right angle boots for all the feeder Modules All the type test certificates as per IEC from Third party NABL / CPRI / ERDA accrediated lab to be submitted. (Cost of RCC Foundation / Steel Structure to be paid Extra) All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR |
| 216 | Extensible 2 way RMU with 1 no. VCB & 1 No. Load Break Switch |
| 217 | Providing & Laying XLPE insulated three core Armoured Aluminium cable for working voltage 11 K.V.(E) confirming IS :7098 P - 2 with H4- Grade electrolytic aluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 218 | 3 core 95.0 Sq.mm |
| 219 | Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit suitable for 11 KV / 33 KV (Earthed) cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 which covered all sequence for table 2 for termination kit and table 3 for streight through joint inclusive thermal & dynamic short circuit test, humidity test, soil fog test. Cross linking shall be done out side factory with E- beam/ peroxide technology. Extrusion process shall be in house OEM within same vicinity. including testing etc. as required of following sizes. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 220 | 3 core 50/70/95 Sq.mm |
| 221 | 3 core 50/70/95 Sq.mm |
| 222 | Plate Earthling as per IS:3043 with copper Earth plate of size 600mm x 600 mm x 3.0mm by embodying 3 to 4 mtr. Below the ground level with 25 mm dia. G.I. ‘B’ class watering Pipe including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. |
| 223 | Pipe Ear thing as per IS: 3043 with perforated 3.0 Mtr. Long, 40 mm dia. ‘B’ class G.I. Pipe including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300 mm and embodying the pipe complete with alternate layers salt and coke/charcoal, testing of earth resistance as required. |
| 224 | S & Laying following size ‘B’ Class G.I. Pipe confirming to IS: 1239 P-1 (1990) with accessories for laying earth conductor/ strip/ cable in ground/ surface/ recess as required. |
| 225 | 50 mm dia. |
| 226 | Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 227 | 50mm x 6mm copper strip |
| 228 | 25mm x 6mm G.I. ( Hot Dipped ) Strip |
| 229 | 32mm x6mm G.I. ( Hot Dipped ) Strip |
| 230 | 50mm x 6mm G.I. ( Hot Dipped ) Strip |
| 231 | Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized iron cable tray ( Galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 232 | 100mm x 50mm x 1.6mm |
| 233 | 150mm x 50mm x 1.6mm |
| 234 | 300mm x 50mm x 1.6mm |
| 235 | Supplying and drawing PVC insulated & sheathed solid/ stranded copper conductor multi core control cable ISI marked (IS:1554) of 1.1 kV grade of approved make as per chapter E11,in existing surface or recessed conduit/ casing capping including making connections etc. as required. |
| 236 | 4 core, 1.5 sq. mm. armoured |
| 237 | 8 core, 1.5 sq. mm. armoured |
| 238 | 8 core, 2.5 sq. mm. armoured |
| 239 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 240 | 400 SQMM, 3.5 CORE |
| 241 | 300 SQMM, 3.5 CORE |
| 242 | 120 SQMM, 3.5 CORE |
| 243 | 150 SQMM, 3 CORE |
| 244 | 120 SQMM, 3 CORE |
| 245 | 95 SQMM, 3 CORE |
| 246 | 70 SQMM, 3 CORE |
| 247 | 35 SQMM, 3 CORE |
| 248 | 6.0 SQMM, 4 CORE |
| 249 | 4.0 SQMM, 3 CORE |
| 250 | Electric Panels Items |
| 251 | SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d, (e), (f), (g), (h) as below:- (a)Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. [c) nterconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. (f)Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra ) (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .busbar and Switchgear is to be Paid Extra ) (d)Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee |
| 252 | Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator with standard short circuit withstand capacity , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 253 | Electrolytic grade Aluminium bus bar 6010 grade |
| 254 | Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type (up to 500) V range Volt meter / Direct- Ammeter / CT oertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracy as per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 255 | Three phase with universal Auxiliary supply + AMP + HZ + PF + KW + KVA + KVAR + KVARH + KWH + DUAL ENERGY+ ENERGY+THD-I, THD-V & RUN HRS + MD with RS485 |
| 256 | Three phase AMP+HZ+PF+KW+KVA+KVAR+T.ENERGY+THD-I, THD-V & RUN HRS |
| 257 | Providing & Fixing of BIS approved Current Transformer as per PWD specification for electrical Works ,ISI marked as per IS 2705-1992/ conforming to IEC 60044-1, with secondary terminal of CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as required Current transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in-charge.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 258 | C T Class 1, Ratio 400/5 to 1200/5, Burden 15 VA |
| 259 | Providing & Fixing of Cam operated rotary (Auto/manual) switches on existing panel with 2 way and off position using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc. as required . All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 260 | 10 AMP |
| 261 | 16AMP |
| 262 | Providing & Fixing of 110/220 V, unibody LED Indicating lamp IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 263 | Red/yellow/Blue |
| 264 | Red/Gree/ white Colour |
| 265 | Red/Gree/ white Colour |
| 266 | Red/Green |
| 267 | Providing & Fixing of flush head push button actuators IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, including connection etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR |
| 268 | Non luminous type |
| 269 | Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 / 2006 with one side anti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 270 | 11 KV, Class B 2.5 mm thick with proof voltage 22 KV AC (rms) and Break Down Voltage 45 KV AC (rms) |
| 271 | SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% ICU. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 272 | 400 Amp , 35 kA, adjustable O/L & adjustable S/C setting, |
| 273 | 630 Amp , 50 kA, adjustable O/L & adjustable S/C setting, |
| 274 | Extended Rotary Handle |
| 275 | Mechanical Interlocking kit |
| 276 | Auxiliary + Trip alarm contact |
| 277 | Spreaders for 400A, 4 Pole MCCB |
| 278 | Spreaders for 630A, 4 Pole MCCB |
| 279 | 6 to 8 stage |
| 280 | 12 to 14 stage |
| 281 | Providing & Fixing of self healing IP20 MPP type shunt capacitor (banks) conforming to IS:13340-41 / IEC :831-1&2 OR IEC : 60831-1& 2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz, Operating loss less than 0.30 Watt per KVAR. Min over current capacity 1.8 times rated current & peak inrush current min. 300 times of rated current, llife expectancy greater than 100000hrs (temp class - 25 D) in 440 V/480 V Capacitor and for 525 V should life expectancy minimum 1,65,000 hrs (temp class - 25 D) including making connections, testing etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 282 | Heavy duty Three phase 440 V, 50 Hz cylindrical type capacitor (Bank) |
| 283 | Providing & Fixing of 440 Volt 3 pole capacitor (AC 6 B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current as per PWD specification for electrical Works, IS/IEC 60947-4-1 : 2000, insulation voltage 1000V, impulse withstand voltage 8 KV,Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 284 | up to 6 KVAR |
| 285 | 10 KVAR |
| 286 | 15 KVAR |
| 287 | 25 KVAR |
| 288 | 50 KVAR |
| 289 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 290 | Triple pole MCB (With B/C curve trippingCharacteristics), 6 A to 32 A rating |
| 291 | 50/63 A rating |
| 292 | 125 A rating |
| 293 | Four pole MCB (With B/C curve tripping Characteristics), 6 A to 32 A rating |
| 294 | Double pole MCB(With B/C curve tripping Characteristics) , 6 A to 32 A rating |
| 295 | SITC of Soft Starters with panel supplied by manufacturer conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, display of electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus. |
| 296 | 110KW |
| 297 | SITC of Local Push Button station fabricated with 16 SWG CRCA sheet, painted with polyster Powder coated finish after chemical treatment with Folliwng items and accessories:- i Shrouded Type push button with 2 NO Contacts element for Start/forward-reverse. ii Lockable Mushroom head type push buuton with 2 NC Contact element. iii 2.5 Sqmm clipon type terminals as requried with 20% spares. iv 1.5 Sqmm PVC insulated felxible copper wire with lugs & ferrules as requried. |
| 298 | Supply and erection of Galvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular cross-sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 with base plate and foundation bolt on the Existing cement concrete foundation.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 299 | 7 Mtr., Poles with Octagonal Cross Section |
| 300 | Supply and Fixing of Pole OEM fabricated hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 301 | Single arm overhang |
| 302 | Providing and Laying RCC Foundation for Octagonal / Conical Street Light poles, High mast Poles as per Drawing attach at Table P-4 with Following Procedure & All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . A) Excavation of Pit for Foundation Size upto required depth from Ground level B) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surface complete. C) Providing and laying in position cement concrete of M-10 grade of 75 mm thickness D) Reinforcement for R.C.C. work with TMT bars including straightening, cutting, bending, placing in position and binding all complete. E) Centring and shuttering including strutting , propping etc. and removal of form work for Footing and Pedestal F) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe & Foundation Bolt with template as per OEM Recommendations. G) Providing and Laying Reinforce cement Concrete of M-25 grade in Footing and Pedestal including Curing the foundation for 7 days. H) Providing and Fixing Nosing Angle 40 mm x 40 mm x 6mm with 2 no. 100 mm long, 10 mm dia. Lugs on each face. |
| 303 | Pole Foundation for Octagonal pole from 7 Mtr. To 9 Mtr. |
| 304 | Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 305 | LED Street Light fixture with Minimum lumen output 8700 lm |
| 306 | Providing & Fixing of IP - 65 protected impact resistant polycarbonate / Polysterene enclosures with knock out for cable entry/out including fixing with nut, bolt, fatner etc as required complete in all respect of following sizes.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 307 | 180 x 180 x 91 mm |
| 308 | Providing & Fixing of Street light bracket made out from following size of ' B ' class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 309 | 32 mm Dia. |
| 310 | Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 311 | High Power LED Flood Light Minimum lumen output 10000 lm |
| 312 | Providing and fixing in position lightening arrester set complete with 600mm x 600mm x 6mm thick G.I. earthing plate embedded below ground in earthling pit at 3.5 metr depth, G.I. strip of size 25mmx5mm thick from earthing plate to top of Over head tank, G.I. Finial made of GI bar 25mm dia and 2m long fixed on top of OH tank and connected to GI strip. The earthling set shall comply of IS:3043 complete in all respect as per specification and the direction of the Engineer. |
| 313 | Heavy Duty AL & CU Lugs, Double Compression Cable Gland with Nickel Plated, Cable Tie, Cable Tags, GI Nut- Bolts-Washers, Anchor Fastners, Clamps, Clips, Screw, Washers, Electrical Taps, HT Tap, Danger Plates, Condut Pipe, 40mm uPVC Pipe, 4.5 Kg. CO2 type portable fire extinguisher for Panel Room , Fire buckets with floor / wall mounting stand ect. required hardware & accessories for various sizes as per site requirements. |
| 314 | 11KV Switchyard Civil work for Transformers Foundations, DP Structure, Chain Link Fencying 1500mm Height, MS Gate , 40mm Gravels, boundary wall, Earthing Chambers, HT/LT cable Trench,covers ect. |
| 315 | 433VAC LT Panel for DMA Remote locations in cubicle made of CRCA sheet steel of minimum 2.5/2.0/1.6 mm thickness, comply with latest IS/ IEC, totally enclosed Operational on 3+1 Phase 433 voltages, 50Hz, neutrally grounded, IP 5X, The cubicle panel shall be vermin proof and dust-tight and shall be of compartmentalized type construction, powder coating, Paint Shade – Grey RAL 7032, gasket material- neoprene, AC/DC/CT wiring – 1.5/2.5sqmm PVC insulated multi strand Copper flexible wire, Heat shrinkable Colour coded PVC bus bar sleeves, cable entry Incoming – bottom and outgoing – Bottom as per requirement. The switchgears and control gears complete with all necessary supporting framework, nuts and bolts, Aluminum Bus Bar. The indoor Panel switchegears (MCB, CTs, Contactors, auxiliary contacts, Space heater and lighting, RDOL for electrically operated laves with Selector Switch, Phase Indications, Hooter, plug socket etc.) shall be mounted on the same panel. Outdoor Panels shall be self-fabricate type only with Canopy, PLC & SCADA Compitible, complete operation carried for max. nos RDOL , Size - 450*300*600mm (for Electrically Operated Valve sin Remote) as per technical specifications and as directed by Engineer in charge. ( Prices are excluding EOV & EMF/BFM & fittings/ 3 Phase Power Connections at Remote locations ) |
| 316 | Design, Manufacture, Supply, Installation, Testing and Commissioning of Indoor type PLC Panel of size approx. 800 mm X 500 mm X 2000mm (LBH) , Fabricated out of min. 2 mm thick CRCA sheet complete with latest configuration, necessary programming software for PLC & SCADA and comprising of all accessories not limited to the following: DI 30 No. DO 26 No. AI 6 No. AO 2 No. MCB 16A DP 2 No. MCB 6A DP 6 No. SMPS 100-240VAC/ 4.5A / 24 VDC 1 No. Selector Switch (Auto/Manual) & Local / Remote 2 No. Control Relays 1 Lot Annunciator with 24 Windows NO to NC Type Microprocessor Based, Window Size 75*42mm, 110VAC, with 1 No. Electronic Hooter 1 No. Control Transformer 200VA 1 No. Emergency STOP Push Button 1 No. Panel Cooling Fan & Filter 2 No. Panel Light with Door Switch, 7W 1 No. Control Indication Lamp for 24VDC, 220VAC 3 No. Push Button 3 No. Power Wiring+Control Wiring + Control TB/ Fuse 2A,TB etc 1 Lot Panel Hardware, lugs, terminations, ferruls, name plate Ect. 1 Lot UTILITY SOCET 16A, 3 PIN 2 No. HMI Display 10 Inch, Colour 1 No. Isolators Dual Output, 24VDC 1 Lot |
| 317 | Design, Manufacture, Supply, Installation, Testing and Commissioning of Indoor type PLC Panel of size approx. 800 mm X 500 mm X 2000mm (LBH) , Fabricated out of min. 2 mm thick CRCA sheet complete with latest configuration, necessary programming software for PLC & SCADA and comprising of all accessories not limited to the following: DI 62 No. DO 58 No. AI 14 No. AO 6 No. MCB 16A DP 2 No. MCB 6A DP 6 No. SMPS 100-240VAC/ 4.5A / 24 VDC 1 No. Selector Switch (Auto/Manual) & Local / Remote 2 No. Control Relays 1 Lot Annunciator with 24 Windows NO to NC Type Microprocessor Based, Window Size 75*42mm, 110VAC, with 1 No. Electronic Hooter 1 No. Control Transformer 200VA 1 No. Emergency STOP Push Button 1 No. Panel Cooling Fan & Filter 2 No. Panel Light with Door Switch, 7W 1 No. Control Indication Lamp for 24VDC, 220VAC 3 No. Push Button 3 No. Power Wiring+Control Wiring + Control TB/ Fuse 2A,TB etc 1 Lot Panel Hardware, lugs, terminations, ferruls, name plate Ect. 1 Lot UTILITY SOCKET 16A, 3 PIN 2 No. HMI Display 10 Inch, Colour 1 No. Isolators Dual Output, 24VDC 1 Lot |
| 318 | Design, Manufacture, Supply, Installation, Testing and Commissioning of Indoor type PLC Panel of size approx. 800 mm X 500 mm X 2000mm (LBH) , Fabricated out of min. 2 mm thick CRCA sheet complete with latest configuration, necessary programming software for PLC & SCADA and comprising of all accessories not limited to the following: DI 102 No. DO 98 No. AI 22 No. AO 16 No. MCB 16A DP 2 No. MCB 6A DP 6 No. SMPS 100-240VAC/ 4.5A / 24 VDC 1 No. Selector Switch (uto/Manual) & Local / Remote 2 No. Control Relays 1 Lot Annunciator with 24 Windows NO to NC Type Microprocessor Based, Window Size 75*42mm, 110VAC, with 1 No. Electronic Hooter 1 No. Control Transformer 200VA 1 No. Emergency STOP Push Button 1 No. Panel Cooling Fan & Filter 2 No. Panel Light with Door Switch, 7W 1 No. Control Indication Lamp for 24VDC, 220VAC 3 No. Push Button 3 No. Power Wiring+Control Wiring + Control TB/ Fuse 2A,TB etc 1 Lot Panel Hardware, lugs, terminations, ferruls, name plate Ect. 1 Lot UTILITY SOCKET 16A, 3 PIN 2 No. HMI Display 12 Inch, Colour 1 No. Isolators Dual Output, 24VDC 1 Lot |
| 319 | Quad-band GPRS/IOT/VPN/GSM/CLOUD 3G/4G/5G modem with Ethernet bridge/router/ serial server (RS232/485) interface. |
| 320 | SITC of Intelligent Manageable Ethernet Switches providing 24 x 10/100/1000 Fast Ethernet ports- and 2 dual purpose uplink (provision for Copper / Fibre Giga connectivity) with LAN based Software. The LAN based S/W supports enhanced integrated security, including Network Admission Control (NAC), advanced quality of service (QoS), availability and scalable management to enable new converged applications |
| 321 | Providing, installation, testing and commissioning of ONLINE UPS SYSTEM, Single Phase 230 V, 50 Hz with 2 hour backup SMF battery bank as per specification |
| 322 | 1 KVA |
| 323 | Providing and laying Stranded/ Flexible Annealede Bare copper conductor ,XLPE/PVC insulated suitably laid up together overall polyster taped Al (inner sheated GI Steel wire Mylar/Drain wire) along with ATC drain wire , round/steel armoured overall PVC sheathed (ST-1) overall screened Core armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009. |
| 324 | 24 CORE, 1.0 sq. mm. |
| 325 | 4 CORE, 1.0 sq. mm. |
| 326 | Providing and laying Stranded/ Flexible Annealed Bare copper conductor ,XLPE/PVC insulated suitably laid up together overall polyester taped Al (Mylar tape wrapped) along with ATC Drain wire overall PVC sheathed (ST-1) overall screened Pair armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009. (2 Pair * 0.75SQMM) |
| 327 | Providing, Installation, Testing and Commissioning of Pressure Transmitter : Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA with HART / Diaphragm: SS316L / Process Connection: 1/2 \\"NPT (M) / Accuracy: 0.15% Protection: IP67 |
| 328 | Providing, installation, testing and commissioning of Diaphragm Type Pressure Gauges Dial size 150 mm glycerin filled shatterproof glass, Over range protection: 125% of maximum pressure, Material of sensor and other wetted parts: SS type 316, Housing material: Die cast aluminum |
| 329 | Providing, installation, testing and commissioning of Diaphragm type Pressure Switches Sensing Element: Bellows / Diaphragm, Material of sensor and other wetted parts: SS type 316, Housing: Die cast aluminum, Switch type: Microswitch, Repeatability: ± 1% of span, Switch Contacts: 2 NO + 2 NC |
| 330 | Providing, installation, testing and commissioning of Level Switch ( Conductivity) Conductivity Probes, Probe insulation: Teflon, Probe head protection class: IP 65 of IS 13947 Part I, Probe head housing material: Aluminum |
| 331 | Rigid for lengths of up to 3 Mtr. |
| 332 | The Cloud based Water management & Data Monitoring system for the real time data analysis of the field instruments/pumps/valves/actuators located in the CPS / IPS/ any other field remote locations. 16 pump houses & the system working, a dedicated Cloud Server Instance will be provided with Database to store historical data of up to 5 years. The PLC system available in each pump house will send the data through Sim-based Modem to the Cloud at a time interval of 15 seconds. A Dashboard with all mentioned Locations will be created with an Overview of each Pump house & further the status of Pumps, running hours, status of valves, Tank Water Level, Pressure and all-important values will be displayed & stored in database.In total 3 users will be provided with the Monitoring Access of the system & 1 user will be provided with the Operation Access. A Daily/Weekly/Monthly Report Generation & download option will be provided with a standard predefined format. |
| 333 | Cloud based Water management & Data Monitoring system Dash Board (12 Months * 5 years) |
| 334 | Cloud based Water management & Data Monitoring system setup 5-year infrastructure Design & Development |
| 335 | Cloud based Water management & Data Monitoring system monthly Recurring Charges (12 Months * 5 years) |
| 336 | Modular RTU complete with DI, DO, AI and modbus communication ports and power supply 24 VDC or for variable power supply using batteries, rechargeable batteries, solar or 10.8 V DC to 28.8 V DC with integrated modem; connection to control center via Tele Control Basic, DNP3, IEC60870-5-104 and Communcatin protocols, on-board I/Os min. (8 DI, 4 DQ, 2 AI), configuration and diagnostics per (GSM/UMTS), Mini SIM card, with adapter Micro SIM card also, GPRS (Multi-slot Class 10), 35 mm DIN rail mounting, TCP/IP, DNP 3, Open VPN-Client. Panel Enclosure for Compact RTU Location, wall/floor mounted along with wiring and related accessories and arrangement of mounting of RTU, Modem having IP-5X Protection. Panels shall be self-fabricate type only with Canopy. |
| 337 | Chlorine Analyser : Transmitter : Range: 0.05 to 20 ppm, Power Supply 230 VAC, Input: 2 Digital Sensors - one for chlorine and second for pH, Output: 4-20mA HART, IP66/67 Protection / Tx protection cover required / Sensor Range 0-14 pH , able to transmit digital signal to transmitter, calibration data can be transferred to Transmitter , process temp: 65 deg cen/ Sensor range:0.05 to 20 mg/l. |
| 338 | Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS:8329-2000 (amended upto date), with internal cement mortar lining for potable water with rubber ring (EPDM/SBR) joints as per IS: 5382-1985 (excluding special accessories) complete including all material, labour, hydraulic testing and commissioning as per Technical Specifications and as per direction of Engineer.Note : E/w to be measured and paid separately. |
| 339 | 100 mm |
| 340 | 150 mm |
| 341 | 200 mm |
| 342 | 250 mm |
| 343 | 300 mm |
| 344 | 350 mm |
| 345 | 400 mm |
| 346 | 450 mm |
| 347 | 500 mm |
| 348 | 600 mm |
| 349 | Providing, lowering, laying, aligning, fixing in position at and jointing at all level/ depths ISI marked HDPE pipes of PE-100 grade & PN-6 for potable water as per IS 4984 (amended upto date) in trenches in complete including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer.Note : E/w to be measured and paid separately. |
| 350 | 110mm dia |
| 351 | 125mm dia |
| 352 | 140mm dia |
| 353 | 160mm dia |
| 354 | 180mm dia |
| 355 | Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level. |
| 356 | In all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc. |
| 357 | Depth upto 1.5 m |
| 358 | Add extra for over all depth of excavation above 1.5 m and upto 3.0 m over item no 4.1 |
| 359 | Dismantling of flexible pavement for pipe line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, rehandling of material/earth to complete the tasks per technical specification andscope of work. |
| 360 | Bituminous courses |
| 361 | Granular courses |
| 362 | Dismantling of cement concrete pavement by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposalof dismantled materials up to a lead of 1000 metres including allowances for any additional dismantling beyond the drawings (measurement for payment to be as per standard drawings), rehandling of material/earth to complete the task. |
| 363 | Barricading work |
| 364 | Barricading with Sal ballies as per designincluding tying with vertical post by coconutstrings including digging out holes in all types of soil complete in all respect with two horizontal members height 1.2 m upto 1.5m above ground level and vertical supports upto 2.5 centre and upto 3 days period including removal and cleaning the site complete in all respect & including dressing of sides and providing retro reflective tapes for traffic safety as per direction of Engineer-in charge in all types of soil. |
| 365 | P & F of Open timbering in trenches including strutting, shoring complete (measurements to be taken of the face area timbered). Depth exceeding 1.5 Mtr. but not exceeding 3 Mtr |
| 366 | Providing, lowering, laying, aligning, fixing in position in pipe line, Resilient Seated D/F DI Sluice valves of approved make & design standard of following dia complete (including jointing & jointing material ) including all material, labour, testing and commissioning along with pipe line as per Technical Specification & as per direction of Engineer. (Calculation of Valve attached at Annex -E16(3) |
| 367 | Manually operated class PN 1.6 |
| 368 | 100 mm dia |
| 369 | 150 mm dia |
| 370 | 200 mm dia |
| 371 | 250 mm dia |
| 372 | 300 mm dia |
| 373 | 350 mm dia |
| 374 | 400 mm dia |
| 375 | 450 mm dia |
| 376 | 500 mm dia |
| 377 | Electrically Operated & SCADA Compatible class PN 1.6 |
| 378 | 80 mm dia |
| 379 | 200 mm dia |
| 380 | 300 mm dia |
| 381 | 350 mm dia |
| 382 | 400 mm dia |
| 383 | 450 mm dia |
| 384 | 500 mm dia |
| 385 | Providing, lowering, aligning, fixing in position and Jointing in pipe line, DI Body Flanged End Tamper proof Kinetic Air Valve class PN 1.6 of approved makes of following pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(amended up to date) Body, High pressure cover , Low pressure cover, Cowl and Joint support ring - Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, Float- LP ball & HP ball : AISI 304 stainless Steel, Seat ring & Gasket - EPDM/NBR ,HP Orifice & HP orifice plug : Bronze/ SS ,Bush: Bronze ,Flanges as per IS/ BS, Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non- Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & cover inside and outside fasteners - CS/ Galvenised steel, Outlet of big orifice will have a screen to prevent Tamper of float, with DI metal seated D/F Non rising stem Sluice Valves as per (IS: 14846 amended upto date) PN 1.6 ratings Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work |
| 386 | 40 mm dia |
| 387 | 50 mm dia |
| 388 | 80 mm dia |
| 389 | 100 mm dia |
| 390 | 150 mm dia |
| 391 | 200 mm dia |
| 392 | Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer. |
| 393 | 80 mm dia PN-1.0 |
| 394 | 100 mm dia PN-1.0 |
| 395 | 150 mm dia PN-1.0 |
| 396 | 200 mm dia PN-1.0 |
| 397 | 250 mm dia. |
| 398 | 300 mm dia. |
| 399 | 350 mm dia. |
| 400 | 400 mm dia. |
| 401 | 450 mm dia. |
| 402 | 500 mm dia. |
| 403 | Construction of RCC Sluice valve chamber for different type of valves including earthwork excavation, 100mm PCC M15 as levelling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast slabs, plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as per direction of Engineer-in-Charge. |
| 404 | For Class-AA loading |
| 405 | Sluice valve chamber of size 1.13 m x0.85 m x1.325 m-for pipe size-up to 100 mm |
| 406 | Sluice valve chamber of size 1.17m x 0.95m x1.47mfor pipe size-from 125-to-150mm |
| 407 | Sluice valve chamber of size 1.26m x1.185m x1.88m for pipe size-from 200-to-300mm |
| 408 | Sluice valve chamber of size 1.39m x1.43m x2.245mfor pipe size-from 350-to-450mm |
| 409 | Sluice valve chamber of size 1.61m x1.75m x2.85mfor pipe size-from 500-to-700mm |
| 410 | Construction of RCC Air valve chamber for different type of valves including earthwork excavation, 100mm PCC M15 as levelling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast slabs, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as per direction of Engineer-in-Charge. |
| 411 | For Class-AA loading |
| 412 | Air valve chamber of size0.9m x1m x1.695mfor air valve size-from 50 mm-to-80mm |
| 413 | Air valve chamber of size1m x1.1m x1.945m for air valve size of 100mm |
| 414 | Air valve chamber of size1.05m x1.4m x2.42mfor air valve size of 150mm |
| 415 | Air valve chamber of size1.325m x1.7m x2.875m for air valve size of 200mm |
| 416 | Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths DI standard specials with rubber ring (EPDM)/ nut bolt and insertion sheet and jointing as per IS: 9523-2000 or as amended up to date, such as tees, bends, tapers, caps etc. within trenches in DI pipe line complete including all material, labour, taxes, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge (excluding earth work). |
| 417 | Upto 300mm dia |
| 418 | Above 300mm dia and upto 600mm dia |
| 419 | SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/Chlorinated) , Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU), Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement of IEC60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC -50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, if required, and all materials required for making connection etc. complete in all respect as per technical specification and direction of Engineer In-Charge. Note: Rates are exclusive of tail piece / dismantling joints and earth work. |
| 420 | EFM 80 mm |
| 421 | EFM 200 mm |
| 422 | EFM 300 mm |
| 423 | EFM 400 mm |
| 424 | EFM 450 mm |
| 425 | EFM 500 mm |
| 426 | Providing and fixing of flanged/ plain ended MS pipe made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete (excluding flanged jointing wherever required) including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer. |
| 427 | MS pipe upto 600mm dia (with minimum 5mm thickness sheet) |
| 428 | Providing Household Tap Connection as per technical specification and approved drawing as per relevant IS code (amended up to date) from uPVC/DI/AC/MS/GI pipe line up to consumer meter/premises by using PP/MS saddle piece (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil (excluding road); depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance with specification for potable water including MS/PP saddle piece, gunmetal ferrule 4.0 mm , GM Full-way Valve (IS:778 Mark) or ball valve (min. weight 165 gm) and specials, below ground level 20 mm nominal dia MDPE pipe PE 80 PN 16 as per ISO 4427 / 20 mm nominal dia PPR-C (Three layered) pipe PN16 SDR 7.4 (IS:15801:2008) (ISI mark) and above ground level using 20 mm dia PPR-C pipe with standard PPR fittings/ 15 mm dia GI pipe with fittings in the premises for fixing a tap / meter box (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level.Note: Road cut and restoration is not part of this item and paid separately. |
| 429 | Note: Road cut and restoration is not part of this item and paid seperately. |
| 430 | For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr. |
| 431 | Shifting of Existing Connections |
| 432 | Road cutting for house hold service connection in minimum trench width wherever road crossing is required. Road cutting of cement concrete,WBM, Black top etc. of all thickness shall be done by using a concrete cutter machine keeping minimum trench width and restoration of the road with Cement concrete with PCC M-10 and CC M-30 grade as per specification and direction of Engineer in charge.. |
| 433 | Supply, Installation of 15 mm size AMI LoRa WAN/RF based Water Meters, conforming to ISO 4064:2005/ISI standards with MID/ISI approval including Collection & Verification of Consumer Data, Automated Meter Reading in the identified DMAs of MC Jaipur Greater. |
| 434 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : |
| 435 | Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc. |
| 436 | Columns, pillars, posts and struts etc. |
| 437 | Arches, domes, vaults etc exceeding 6 Mtr span |
| 438 | Add extra for additional height in centring, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan are is to be measured) |
| 439 | Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcement for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.M20 grade Nominal Mix / Design Mix |
| 440 | Add extra for providing richer mixes respectively at all floor levels |
| 441 | Providing M-35 grade concrete by using cement as per codal provision instead of M-20 grade design mix. |
| 442 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. ('Original producers' who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) |
| 443 | Cold twisted deformed bars (IS : 1786). |
| 444 | Painting exterior surface of Wall with 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty, etc complete in all respect including scaffolding and safety provision |
| 445 | New Work |
| 446 | Lettering with black Japan paint of approved brand and manufacture. |
| 447 | Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. |
| 448 | Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide |
| 449 | Supply and fixing in cement mortar welded hand railing made out of MS round or square bars, flats etc. for staircase or verandah as per design complete in all respect (wooden or PVC hand railing to be paid extra) with priming coat of red oxide. |
| 450 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : |
| 451 | Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 452 | Plaster on new surface on wall in cement sand mortar 1:3 including racking of joints etc. complete fine finish : |
| 453 | 20mm thick |
| 454 | Random Rubble stone masonry with hard stone in superstructure above plinth level and upto five level above 30cm. thick walls in :Cement Mortar 1:4 ( 1-Cement : 4-Sand). |
| 455 | 5.2 Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : 5.2.1 Cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 456 | 5.19Half Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 100 in superstructure above plinth level upto floor V level in. Cement mortar 1 : 4 (1 cement : 4 coarse sand) Sqm 586.00 |
| 457 | Plaster on new surface on wall in cement sand mortar 1:3 including racking of joints etc. complete fine finish :20mm thick |
| 458 | Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete New Plastered Surface (three or more coats) |
| 459 | Finishing walls with textured exterior paint of required shade as per approved colour complete as per manufacturers specifications including primer coat and protecting coat including scaffolding and safety provision ;New Work; PUMP HOUSE PAINTING WORK |
| 460 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: INTERIOR;Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. |
| 461 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work.,Note: Pump & other railing works,door windows, including etc, |
| 462 | Painting (two or more coats) on rain water soil, waste and vent pipes and fitting with black anticorrosive bitumastic paint of approved brand and manufacture over and including a priming coat of ready mixed zinc chromate yellow primer on new work : |
| 463 | Finishing walls with textured exterior paint of required shade as per approved colour complete as per manufacturers specifications including primer coat and protecting coat including scaffolding and safety provisionRoller Finish av. thickness 400 to 500 microns.; / ESR & CWR PAINT WORK |
| 464 | 9.10 Providing and fixing of precast concrete interlocking tiles of desired shape of M 30 grade manufactured from fully computerized automatic stationery hydraulic vibrio pressed machine and fully computerized automatic batching plant of class A1/A2 as per BS 6717:2001. The CC interlocking paving blocks be laid on average 50mm. thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined. Complete job is to be executed as per the instruction of Engineer incharge. The rates to be inclusive of all lead & Lifts etc. complete as per specifications. Tensile splitting strength, abrasion and braking load etc. as per BS 6717:2001, Grey cement;100 MM THICKNESS |
| 465 | 100mm thick |
| 466 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. |
| 467 | M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 468 | 4.13 Earth filling with available surplus soil excavated from foundationsand taken only from outside of building plinth in layers not exceeding 20cm in depth, consolidating each deposited layer including ramming and watering and consolidation with lead up to 50 m and lift upto 1.5 m. |
| 469 | Carriage of Materials by mechanical transport including loading, unloading and stacking ::Cost of carriage including loading, unloading & stacking for first 50 m. |
| 470 | 9.19 Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038- 1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required |
| 471 | Crazy marble stone flooring including filling the gaps with light shade pigment with white cement marble powder mixture (3 parts of white cement : 1 part of marble powder) by weight in proportion of 4:7 (4 cement marble powder mix : 7 white, black or white and black marble chips of sizes from 1mm to 4mm nominal size by volume) and under layer 25mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) rubbing, polishing and cement slurry etc. complete :30.16.1 18 mm thick crazy marble stone white, black or as specified. |
| 472 | Providing and laying in position Ready mix concrete manufactured in fully automatic Batching Plant and transported to site in transit mixer for having continous agitated mixer, manufactured as per approved mix design of specified grade of RCC work including pumping of R.M.C. from transit mixer to site of laying , exculding the cost of centering, shuttering and reinforcement with all lead and lift including cost of admixtures in recommended portion as per IS 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. All works upto floor V floor M20 grade Design Mix by using cement as per codal provision. |
| 473 | Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed : All kinds of soil |
| 474 | Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc. |
| 475 | Columns, pillars, posts and struts etc. |
| 476 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. |
| 477 | M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate20mm nominal size). |
| 478 | Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and makinggood the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix |
| 479 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. ('Original producers' who manufacture billet directly from iron ores and roll the bilets to produce steel conforming toIS:1786) |
| 480 | Thermo-mechanically Treated bars (Conforming of relevent IScode) |
| 481 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: |
| 482 | Painting exterior surface of Wall with 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty, etc complete in all respect including scaffolding and safety provision |
| 483 | New Work |
| 484 | Supply laying and pushing of MS casing pipe of specified thickness approved by concerned department authority by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per Highway/ Railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MS cutting edges for front shield and constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved by authority specification and the direction of the Engineer.Apply corrosion, resistant, protection on inside and outside of casing pipe as per technical specification. |
| 485 | 400 mm Dia 8 mm thick casing pipe . |
| 486 | 500 mm Dia 8 mm thick casing pipe . |
| 487 | 600 mm Dia 10 mm thick casing pipe . |
| 488 | Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS AISI 316/410 Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 489 | Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 |
| 490 | 200 mm dia |
| 491 | 250 mm dia |
| 492 | 300 mm dia |
| 493 | Construction of RCC Sluice valve chamber for different type of valves including earthwork excavation, 100mm PCC M15 as levelling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast slabs, plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as per direction of Engineer-in-Charge. |
| 494 | For Class-A loading |
| 495 | Sluice valve chamber of size1.26m x1.185m x1.82mfor pipe size-from 200-to-300mm |
| 496 | Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning Technical Specifications and as per direction of Engineer. Class PN 1.0 |
| 497 | 200 mm dia. |
| 498 | 250 mm dia. |
| 499 | 300 mm dia. |
| 500 | Cost for Basic Service Charges, Administration and Management, Running of Operation, Maintenance and Repairs including Preventive Maintenance, Cost of material required for maintenance & repairs, Cost of Lubricants, Consumables, Spare Parts (if the spare parts supplied to PHED are used in emergency) as per Scope of Work & terms & conditions of contract for 5 year after defect liability period of one year DLP (except power feeder, IEC & miscellaneous provision) for Water Supply Project |
| 501 | 1st year |
| 502 | 2nd year |
| 503 | 3rd year |
| 504 | 4th year |
| 505 | 5th year Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 26 daysNov 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 27 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender