Housing Urban and Rular Development Government Departments Closing in 2 days TDR #57909088

Tender For Construction Of Medical Sub Centre At Matah Under District Capex Budget For The Year 2026-27

Issued by Government Departments · Reasi, Jammu and Kashmir
Tender Value
77.71 Lakhs
Estimated cost
Bid Submission
21 Oct 2026
2 days left
EMD
1.55 Lakhs
Bank guarantee accepted
Document Fee
1500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Reasi → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Medical Sub Centre At Matah Under District Capex Budget For The Year 2026-27

BOQ

Name of Work:- Construction of Medical Sub Centre at Matah under District Capex Budget for the year 2026-27
Sl. No. Item Description
1Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All Kind of Soil
2Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kind of Soil
3Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)
4Providing & Laying in position cement concrete 1 cement:3 fine sand:6 graded crushed stone aggregates 20mm size excluding the cost of centring and shuttering all works upto Plinth level with 20% boulders
5Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
6Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
7Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:6 ( 1 cement : 6 coarse sand)
8Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level
9Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in :Cement mortar 1:4 ( 1 cement : 4 coarse sand)
10Extra for half Brick masonry in superstructure above plinth level upto floor V level.
11Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
12Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
13Centring and shuttering including strutting,propping etc and removal of formwork
14A. Foundation , footing,base of columns etc
15B. Columns pillers,posts etc
16C. Plinth beam
17D. Suspended floor,Roofs,landings etc
18F. Edges of slabs and breaks in floors and walls under 20cm wide
196mm thick cement plaster of 1:3 fine sand mix in ceiling
2012mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand)
2115mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 6 ( 1 cement : 6 fine sand)
22Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60mm thickness, including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.60mm pressed, mild steel welded or rigidly fixed together by mechanical means, including M.S pressed butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile B Fixing with adjustable lugs with split end tail to each jamb
23Providing and fixing M.S. grills of required pattern in frames of windows etc.with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete Fixed to openings / wooden frames with rawl plugs screws etc
24Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately. Second class Kail wood 35 mm
25Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. Particle Board 12mm thickPlain particle board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS : 3087 marked
26Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws 35mm Second class Kail wood wood
27Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge :Second class Kail wood 35mm thick
28Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 300x10 mm
29Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete 100x10 mm
30Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 125mm
31Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete (300x16 mm)
32Making plinth protection 50mm thick of cement concrete 1:3:6 graded crushed aggregate 20 mm n/s over bed of dry brick blast 40mm n/s well rammed and consolidated and grouted with fine sand including finishing the top smooth.
33Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete
34Providing and applying plaster of paris putty of 1mm thickness over plastered surface to prepare the surface even and smooth complete
35Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work
36Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.
37Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm)
38Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm
39Providing and fixing 1st quality ceramic glazed floor tiles conforming toIS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarsesand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
40Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
41Kota stone slab 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm ( average) thick cement mortar 1:3 (1 cement:3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing, polishing and curing complete.
42Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type B including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 110 mm diametre
43Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type B including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 75 mm diametre
44Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or More Coat on New Work Including Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)
45Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand 4 graded stone aggregate 20mm nominal size ).
46Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040mm bowl depth 178mm
47Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests.
48Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid.
49Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required One urinal basin with 5 liter white P.V.C automatic flushing cistern.
50Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, includingpainting of fittings and brackets, cutting and making good the walls wherever required :White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
51Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
52Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931
53Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms
54Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931
55Providing and fixing uplasticized PVC connection pipe with brass unions 30 cm length 20 mm nominal bore
56Providing and fixing PTMT grating of approved quality and colour 100mm dia
57Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete: Semi Rigid Pipe 32mm dia
58Providing and fixing wash basin with C.I. brackets, 15 mm PTMT pillar cock, 32 mm PTMT waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm PTMT pillar cock.
59Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge.Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc
60a) 15mm nominal outer dia pipes.
61b) 20mm nominal outer dia pipes.
62Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.
63a) Coupler 75mm
64b) Coupler 100mm
65c) Single tee with door 75x75x75mm
66d) Single tee with door 110x110xz110mm
67e) Bend 87.5° 75 mm bend
68f) Bend 87.5° 110 mm bend
69g) Shoe (plain) 75mm shoe
70h) Shoe (plain) 110mm shoe
71Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality. LD - 2.5 Rectangular shape 600x450 internal dimensions
72Supplying and fixing C.I. cover 300x300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5kg.
73Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarsesand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floatingcoat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
74Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
75Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
76Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in Existing surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
77Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
78Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required.2 X 2.5 SQ.MM + 1 X 2.5 SQ.MM EARTH WIRE.
79Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc. as required.
80Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required.
81Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 8 way (4 + 24), Double door
82Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
83Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40Amp Isolator
84Supplying and Laying of 1 No. PVC/XLPE insulated and PVC Sheathed /XLPE Power Cable of 1.1 KV Grade of Following Sizes in the existing RCC/Hume/DWC/Stone ware/Metal Pipe/Cable Tray as Required. . 4C x10 mm²PVC Almunium Cable
85Supplying and Laying of 1 No. PVC/XLPE insulated and PVC Sheathed /XLPE Power Cable of 1.1 KV Grade of Following Sizes in the existing RCC/Hume/DWC/Stone ware/Metal Pipe/Cable Tray as Required .3.5C x50 mm²PVC Almunium Cable
86Supply and make end termination with brass and almunium lugs for following sizes of PVC Insulated /PVC Sheath /XLPE almunium conductor Cable of 1.1KV Grade as required 4 x 10 mm² (35mm)
87Supply and make end termination with brass and almunium lugs for following sizes of PVC Insulated /PVC Sheath /XLPE almunium conductor Cable of 1.1KV Grade as required 3.5 x 50 mm² (35mm)
88Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 90 mm dia (OD-90 mm & ID-76 mm nominal)
89SITC of pre-wired concealed type LED Down Light 12-15 Watts , lux 135Lm, including connections with 1.5 sq.mm FR PVC insulated copper conductor single core cable and earthing etc as required .
90SITC of pre-wired external Flood Light W/P IP65 including connections with 1.5 sq.mm FR PVC insulated copper conductor single core cable and earthing etc as required .100 W
91Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
92Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
93Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required.
941200mm Ceiling Fan Including all accessories & Fitting
95250mm Exhast Fan Including all accessories & Fitting
96Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. ard.
97Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
98Supplying and laying 1c x 10 sq mm copper cable with pvc insulation through 32mm PVC Conduit, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.
99SITC of 50ltr Gyser
100DK thermoplastic cable Junction/ Termination T boxes 8\\"x10\\"of class IP55/IP65 fitted with two 2-5 Amp MCB strip,4-way terminal block / connectors Incl. copper lugs, Clamps ,nut & bolts washers etc (Hansel or equivalent make) or poles with two way type bracket to be fitted properly inside the door opened gear box provided on the bottom side of the pole.
101200 Watt LED Luminaries of IP 67 protection.
102Surge Protector for the 120/190 watt LED type lighting fixture complete.SPN Type II
1033X1.5 mm 2 PVC insulated multistrand flexible copper wire for service connections from connection plate to the LED luminary individual circuit including loop & earthings laid properly .
104HDPE pipe 50 mm O/D and inner diameter 38mm including trench excavation in hard soil (0.3x0.45x1000m) for laying of 2 Almunium armored cable . The job further inludes refilling back the same and removal of surplus excavated material to an appropriate place.
105LT 6 mm² 4 core Aluminium XLPE Armoured cable to be carried through conduit/pipe U/G or A/G only in case of site constrains excluding cost of pipe & trench excavation. The cable shall include end termination lugs with its rimping /taping.
106Carriage of Sand a 60km by MT
107Carriage of Aggregate 35km by MT
108Carriage of bricks 100Km by MT Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57909088
AUTHORITY Government Departments
TENDER VALUE 77.71 Lakhs
LAST DATE 21-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for Construction Of Medical Sub Centre At Matah Under District Capex Budget For The Year 2026-27
Basic Detail
Tender No e-NIT No.52 of 2026-27 Dated 07-10-2026
Bidding Type Tender
Location
City Reasi
State Jammu and Kashmir
Key Dates
Publish Date 07 Oct 2026
Submission Date 21 Oct 2026
Open Date 22 Oct 2026
Finance
Tender Value 77.71 Lakhs
Tender Fee 1500
EMD 1.55 Lakhs
Exemption Not Available
Document List
a458c14a-b695-4ff2-91d6-82a7b856bb73.html
BOQ_1107785.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Oct 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
html

a458c14a-b695-4ff2-91d6-82a7b856bb73.html

xls

BOQ_1107785.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender