Agriculture Government Departments Closing in 6 days TDR #57908694

Tender For Nabard Ridf Xxx - Replacement Of Petty Para With Energy Efficient Pump-Sets For Dewatering Paddy Fields In Alappuzha, Kottayam And Pathanamthitta Districts Of Kerala

Issued by Government Departments · Alappuzha, Kerala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
24 Oct 2026
6 days left
EMD
9.80 Lakhs
Bank guarantee accepted
Document Fee
1.96 Lakhs
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Alappuzha → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Nabard Ridf Xxx - Replacement Of Petty Para With Energy Efficient Pump-Sets For Dewatering Paddy Fields In Alappuzha, Kottayam And Pathanamthitta Districts Of Kerala , Supply Erection, Testing And Commissioning Of Vertical Axial Flow Pump Set (Non-Submersible) For Various Padashekarams Of Alappuzha, Kottayam And Pathanamthitta District With The Specifications Listed Below: Suitable For Handling Saline And Silty Water With Rpm 1000 (Syn) Or Less. The Material Of Construction Of Flange, Suction Bell, Bowl, Shroud Shall Be Ci With 2% Nickel, Impeller, Shaft, Shaft Sleeve, Fastener And Suction Pipe Shall Be Of Ss 304. Delivery Pipe Should Be In Ss 304 With Minimum Thickness 6 Mm And Of Suitable Length (Varies From 4-10 M) Or As Per Site Condition. The Prime Mover Of The Pump Is To Be 3 Phase Tefc Squirrel Cage Induction Motor Of Reputed Make Operating At 415V +/- 10%, 50 Hz +/- 5% Connection With F Class Insulation, Control Panel Must Have Dust And Vermin Proof Vertical Mounted Cubical Type Panel Board Of Reputed Make With Fcma Soft Starter Of Reputed Make, Mccb Including Phase Failure Protection, Surge Protection Device, Dry Run Protection, Overload Over Current Protection, Thermal Over Load Protection Relay, Earth Fault Relay, Voltmeter, Ammeter, Fault Indication Start And Stop Switches And Power Factor Correction Capacitor Etc. Wiring And Earthing Should Be As Per Regulations Of Kseb And Electrical Inspectorate. Separate Cubical Type Energy Meter Panel With Ct Metering Provision Including 4 Pole Fn Type Isolator, Rccb , Hrc Fuses And Carrier. Suitable Size Copper Cable For Connection From Electric Post To Meter Box And Meter Panel To Motor Control Panel Etc. Should Be Fitted At Site, With Proper Earthing. Cable Termination Should Be As Per The Regulations And Specifications Of Kseb And Electrical Inspectorate Standards. Screen With 6Mm Gi Welded Mesh With 50Mm X 50Mm Opening Size (About 20 Sq.M Area) Framed In Gi Angles And Gi Tubes Fitted At The Opening On Top And Sides Of Sump To Prevent Entry Of Unwanted Materials To The Pump Through Inflow Water. Proper I-Section Should Be Provided For Supporting The Motor Mountings And Pedestal. Suitable Chain Block And Tripod Facilities To Be Provided For Lifting The Motor At Least 1.00 M Above Maximum Flood Level. Rate Quoted Should Be Inclusive Of All The Charges For Supply, Installation Including Trial Run And Commissioning, All Types Of Transportation And Conveyance, Loading And Unloading Charges, Charges For Factory Testing, But Excluding Gst Etc. , Duty Point Head (M) : 3 Minimum Discharge At Duty Point Head (Lps):266 Working Head Range M:1 To 4.5 Minimum Overall Efficiency (%) At Duty Point Head:70 Available Connected Load (Hp):15 , Duty Point Head (M) : 2 Minimum Discharge At Duty Point Head (Lps):532 Working Head Range M:1 To 4.5 Minimum Overall Efficiency (%) At Duty Point Head:70 Available Connected Load (Hp):20 , Duty Point Head (M) : 3 Minimum Discharge At Duty Point Head (Lps):354 Working Head Range M:1 To 4.5 Minimum Overall Efficiency (%) At Duty Point Head:70 Available Connected Load (Hp):20 , Duty Point Head (M) : 3 Minimum Discharge At Duty Point Head (Lps):443 Working Head Range M:1 To 4.5 Minimum Overall Efficiency (%) At Duty Point Head:70 Available Connected Load (Hp):25 , Duty Point Head (M) :3 Minimum Discharge At Duty Point Head (Lps):532 Working Head Range M:1 To 4.5 Minimum Overall Efficiency (%) At Duty Point Head:70 Available Connected Load (Hp):30 , Duty Point Head (M) :2 Minimum Discharge At Duty Point Head (Lps):1064 Working Head Range M:1 To 4.5 Minimum Overall Efficiency (%) At Duty Point Head:70 Available Connected Load (Hp):40 , Duty Point Head (M) : 3 Minimum Discharge At Duty Point Head (Lps):709 Working Head Range M:1 To 4.5 Minimum Overall Efficiency (%) At Duty Point Head:70 Available Connected Load (Hp):40 , Duty Point Head (M) : 2 Minimum Discharge At Duty Point Head (Lps):1330 Working Head Range M:1 To 4.5 Minimum Overall Efficiency (%) At Duty Point Head:70 Available Connected Load (Hp):50 , Duty Point Head (M) : 3 Minimum Discharge At Duty Point Head (Lps):886 Working Head Range M:1 To 4.5 Minimum Overall Efficiency (%) At Duty Point Head:70 Available Connected Load (Hp):50 , Duty Point Head (M) : 2 Minimum Discharge At Duty Point Head (Lps):1596 Working Head Range M:1 To 4.5 Minimum Overall Efficiency (%) At Duty Point Head:70 Available Connected Load (Hp):60 , Duty Point Head (M) : 3 Minimum Discharge At Duty Point Head (Lps):1064 Working Head Range M:1 To 4.5 Minimum Overall Efficiency (%) At Duty Point Head:70 Available Connected Load (Hp):60

BOQ

Name of Work:- NABARD RIDF XXX - Replacement of Petty para with Energy efficient pump-sets for dewatering paddy fields in Alappuzha, Kottayam and Pathanamthitta districts of Kerala
Sl. No. Item Description
1Supply erection, testing and commissioning of Vertical Axial Flow pump set (Non-Submersible) for various padashekarams of Alappuzha, Kottayam and Pathanamthitta district with the specifications listed below:Suitable for handling saline and silty water with rpm 1000 (Syn) or less. The material of construction of flange, suction bell, bowl, shroud shall be CI with 2% Nickel, impeller, shaft, shaft sleeve, fastener and suction pipe shall be of SS 304. Delivery pipe should be in SS 304 with minimum thickness 6 mmand of suitable length (varies from 4-10 m) or as per site condition. The prime mover of the pump is to be 3 phase TEFC squirrel cage induction motor of reputed make operating at 415V +/- 10%, 50 Hz +/- 5% connection with F class insulation, control panel must have dust and vermin proof vertical mounted cubical type panel board of reputed make with FCMA soft starter of reputed make, MCCB including phase failure protection, surge protection device, dry run protection, overload over current protection, thermal over load protection relay, earth fault relay, voltmeter, ammeter, fault indication start and stop switches and power factor correction capacitor etc. Wiring and earthing should be as per regulations of KSEB and electrical inspectorate. Separate cubical type energy meter panel with CT metering provision including 4 Pole FN type isolator, RCCB , HRC fuses and carrier. Suitable size Copper cable for connection from electric post to meter box and meter panel to motor control panel etc. should be fitted at site, with proper earthing. cable termination should be as per the regulations and specifications of KSEB and Electrical Inspectorate standards. Screen with 6mm GI welded mesh with 50mm x 50mm opening size (about 20 sq.m area) framed in GI angles and GI tubes fitted at the opening on top and sides of sump to prevent entry of unwanted materials to the pump through inflow water. Proper I-section should be provided for supporting the motor mountings and pedestal. Suitable chain block and tripod facilities to be provided for lifting the motor at least 1.00 m above maximum flood level. Rate quoted should be inclusive of all the charges for supply, installation including trial run and commissioning, all types of transportation andconveyance, loading and unloading charges, charges for factory testing, but excluding GST etc.
2Duty point head (m) : 3Minimum discharge at Duty point head (lps):266Working head range m:1 to 4.5Minimum Overall efficiency (%) at duty point head:70Available connected load (hp):15
3Duty point head (m) : 2Minimum discharge at Duty point head (lps):532Working head range m:1 to 4.5Minimum Overall efficiency (%) at duty point head:70Available connected load (hp):20
4Duty point head (m) : 3Minimum discharge at Duty point head (lps):354Working head range m:1 to 4.5Minimum Overall efficiency (%) at duty point head:70Available connected load (hp):20
5Duty point head (m) : 3Minimum discharge at Duty point head (lps):443Working head range m:1 to 4.5Minimum Overall efficiency (%) at duty point head:70Available connected load (hp):25
6Duty point head (m) :3 Minimum discharge at Duty point head (lps):532Working head range m:1 to 4.5Minimum Overall efficiency (%) at duty point head:70Available connected load (hp):30
7Duty point head (m) :2 Minimum discharge at Duty point head (lps):1064Working head range m:1 to 4.5Minimum Overall efficiency (%) at duty point head:70Available connected load (hp):40
8Duty point head (m) : 3Minimum discharge at Duty point head (lps):709Working head range m:1 to 4.5Minimum Overall efficiency (%) at duty point head:70Available connected load (hp):40
9Duty point head (m) : 2Minimum discharge at Duty point head (lps):1330Working head range m:1 to 4.5Minimum Overall efficiency (%) at duty point head:70Available connected load (hp):50
10Duty point head (m) : 3Minimum discharge at Duty point head (lps):886Working head range m:1 to 4.5Minimum Overall efficiency (%) at duty point head:70Available connected load (hp):50
11Duty point head (m) : 2Minimum discharge at Duty point head (lps):1596Working head range m:1 to 4.5Minimum Overall efficiency (%) at duty point head:70Available connected load (hp):60
12Duty point head (m) : 3Minimum discharge at Duty point head (lps):1064Working head range m:1 to 4.5Minimum Overall efficiency (%) at duty point head:70Available connected load (hp):60 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57908694
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 24-10-2026
Authority
Authority Name Department Of Agriculture
Work Description Tender for Nabard Ridf Xxx - Replacement Of Petty Para With Energy Efficient Pump-Sets For Dewatering Paddy Fields In Alappuzha, Kottayam And Pathanamthitta Districts Of Kerala , Supply Erection, Testing And Commissioning Of Vertical Axial Flow Pump Set (Non-Submersible) For Various Padashekarams Of Alappuzha, Kottayam And Pathanamthitta District With The Specifications Listed Below: Suitable For Handling Saline And Silty Water With Rpm 1000 (Syn) Or Less. The Material Of Construction Of Flange, Suction Bell, Bowl, Shroud Shall Be Ci With 2% Nickel, Impeller, Shaft, Shaft Sleeve, Fastener And Suction Pipe Shall Be Of Ss 304. Delivery Pipe Should Be In Ss 304 With Minimum Thickness 6 Mm And Of Suitable Length (Varies From 4-10 M) Or As Per Site Condition. The Prime Mover Of The Pump Is To Be 3 Phase Tefc Squirrel Cage Induction Motor Of Reputed Make Operating At 415V +/- 10%, 50 Hz +/- 5% Connection With F Class Insulation, Control Panel Must Have Dust And Vermin Proof Vertical Mounted Cubical Type Panel Board Of Reputed Make With Fcma Soft Starter Of Reputed Make, Mccb Including Phase Failure Protection, Surge Protection Device, Dry Run Protection, Overload Over Current Protection, Thermal Over Load Protection Relay, Earth Fault Relay, Voltmeter, Ammeter, Fault Indication Start And Stop Switches And Power Factor Correction Capacitor Etc. Wiring And Earthing Should Be As Per Regulations Of Kseb And Electrical Inspectorate. Separate Cubical Type Energy Meter Panel With Ct Metering Provision Including 4 Pole Fn Type Isolator, Rccb , Hrc Fuses And Carrier. Suitable Size Copper Cable For Connection From Electric Post To Meter Box And Meter Panel To Motor Control Panel Etc. Should Be Fitted At Site, With Proper Earthing. Cable Termination Should Be As Per The Regulations And Specifications Of Kseb And Electrical Inspectorate Standards. Screen With 6Mm Gi Welded Mesh With 50Mm X 50Mm Opening Size (About 20 Sq.M Area) Framed In Gi Angles And Gi Tubes Fitted At The Opening On Top And Sides Of Sump To Prevent Entry Of Unwanted Materials To The Pump Through Inflow Water. Proper I-Section Should Be Provided For Supporting The Motor Mountings And Pedestal. Suitable Chain Block And Tripod Facilities To Be Provided For Lifting The Motor At Least 1.00 M Above Maximum Flood Level. Rate Quoted Should Be Inclusive Of All The Charges For Supply, Installation Including Trial Run And Commissioning, All Types Of Transportation And Conveyance, Loading And Unloading Charges, Charges For Factory Testing, But Excluding Gst Etc. , Duty Point Head (M) : 3 Minimum Discharge At Duty Point Head (Lps):266 Working Head Range M:1 To 4.5 Minimum Overall Efficiency (%) At Duty Point Head:70 Available Connected Load (Hp):15 , Duty Point Head (M) : 2 Minimum Discharge At Duty Point Head (Lps):532 Working Head Range M:1 To 4.5 Minimum Overall Efficiency (%) At Duty Point Head:70 Available Connected Load (Hp):20 , Duty Point Head (M) : 3 Minimum Discharge At Duty Point Head (Lps):354 Working Head Range M:1 To 4.5 Minimum Overall Efficiency (%) At Duty Point Head:70 Available Connected Load (Hp):20 , Duty Point Head (M) : 3 Minimum Discharge At Duty Point Head (Lps):443 Working Head Range M:1 To 4.5 Minimum Overall Efficiency (%) At Duty Point Head:70 Available Connected Load (Hp):25 , Duty Point Head (M) :3 Minimum Discharge At Duty Point Head (Lps):532 Working Head Range M:1 To 4.5 Minimum Overall Efficiency (%) At Duty Point Head:70 Available Connected Load (Hp):30 , Duty Point Head (M) :2 Minimum Discharge At Duty Point Head (Lps):1064 Working Head Range M:1 To 4.5 Minimum Overall Efficiency (%) At Duty Point Head:70 Available Connected Load (Hp):40 , Duty Point Head (M) : 3 Minimum Discharge At Duty Point Head (Lps):709 Working Head Range M:1 To 4.5 Minimum Overall Efficiency (%) At Duty Point Head:70 Available Connected Load (Hp):40 , Duty Point Head (M) : 2 Minimum Discharge At Duty Point Head (Lps):1330 Working Head Range M:1 To 4.5 Minimum Overall Efficiency (%) At Duty Point Head:70 Available Connected Load (Hp):50 , Duty Point Head (M) : 3 Minimum Discharge At Duty Point Head (Lps):886 Working Head Range M:1 To 4.5 Minimum Overall Efficiency (%) At Duty Point Head:70 Available Connected Load (Hp):50 , Duty Point Head (M) : 2 Minimum Discharge At Duty Point Head (Lps):1596 Working Head Range M:1 To 4.5 Minimum Overall Efficiency (%) At Duty Point Head:70 Available Connected Load (Hp):60 , Duty Point Head (M) : 3 Minimum Discharge At Duty Point Head (Lps):1064 Working Head Range M:1 To 4.5 Minimum Overall Efficiency (%) At Duty Point Head:70 Available Connected Load (Hp):60
Basic Detail
Tender No ADFW/9457/2023-TG-II
Bidding Type Tender
Location
City Alappuzha
State Kerala
Key Dates
Publish Date 07 Oct 2026
Submission Date 24 Oct 2026
Open Date 26 Oct 2026
Finance
Tender Value Ref. Documents
Tender Fee 1.96 Lakhs
EMD 9.80 Lakhs
Exemption Available
Document List
16749335-9fb8-493b-82bf-8cf13c0e78d6.html
AnnexureI-1.pdf
BOQ_1490254.xls
epay.pdf
KFCFORM14-1.pdf
PreliminaryAgreement-1.pdf
retenderNITalp.pdf
Tendernotice_1.pdf
VAFLocationalp.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Oct 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

16749335-9fb8-493b-82bf-8cf13c0e78d6.html

pdf

AnnexureI-1.pdf

xls

BOQ_1490254.xls

pdf

epay.pdf

pdf

KFCFORM14-1.pdf

pdf

PreliminaryAgreement-1.pdf

pdf

retenderNITalp.pdf

pdf

Tendernotice_1.pdf

pdf

VAFLocationalp.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender