Tender for Repair/ Maintenance Of Dg Sets, Transformer, Pumps Acs, Geysers, Fan, Desert Cooler, Panels And Ro Plants At Loar And Sf Accn Dwarka, New Delhi
BOQ
| Sl. No. | Item Description |
| 1 | M & L for maintenance and servicing of 250 KVA DG set (Make-Cummins) complete including draining out of diesel, draining out engine oil from the sump, flushing the sump and cleaning, replacement of gaskets, fuel filters, oil filters, engine oil,air cleaner elements and the worn out parts like fuel flexible pipes, nuts, bolts, fuel line etc as required, filling the starting batteries with electrolyte, applying petroleum jelly in battery terminals poles, checking of voltage, amps, fuel, coolant and exhaust leakages etc including refilling radiator coolant , tightening all the nuts and bolts to the required torque incl testing to the entire satisfaction in all respect as per directed by Engr-In-Charge. |
| 2 | M&L for repair, maint and servicing to Diesel Engine 125 KVA, 6 cylinder, 1500 RPM prime mover directly coupled with 50 HP Jokey pump for fire fighting services installed at SF accn including dismantling components cleaning ,servicing replacing fuel filters ,lub oil filters ,engine oil of recommended grade including checking servicing of fuel injection pump, technically inspect thge all mechanical and electrical parts and rectify the defects if required, re assembling all the components to its original position and servicing & maint of Jokey pump with testing and commissioning to entire satisfaction for smooth functioning in all complete as per directed by Engr-in-Charge |
| 3 | M&L for maint & servicing of 750 KVA dry power distribution transformer, 11/0.433 KV indoor type including taking out the top cover assembly with gaskets and inspect/ technical checking the windings, loose connections, condition of tap changers, gas level upto required mark terminal boards and cleaning the all dust, dirt or residues on windings or insulators through air compressor / vacuum cleaner. Cleaning the lead supports, tap changers and terminal boards through brushes/wiped with dry lint-free cloth. Technically checking the all HT & LT bushes, loose connection and rectify the defect if required .Checking the HT & LT cable jointing kit, replace the same if required. Charging of transformer and testing to entire satisfaction in all as directed by Engr In Charge. |
| 4 | M&L for repair & maint of 7.5 HP monoblock pump set including decoupling pump & motor, opening the body of motor and technically inspect , taking out burnt/defective winding wire carefully without damaging the stator, cleaning the slot, rewinding the stator with super enameled copper winding wire of existing gauge along with insulating material & varnishing if required and cleaning and servicing of impeller of pump, replace of bearings and greasing,gland packing with bushing if required in all complete to the entire satisfaction and smooth functioning as directed by Engr In Charge. |
| 5 | M&L for repair & maint of 5 HP monoblock pump set including decoupling pump & motor, opening the body of motor and technically inspect , taking out burnt/defective winding wire carefully without damaging the stator, cleaning the slot, rewinding the stator with super enameled copper winding wire of existing gauge along with insulating material & varnishing if required and cleaning and servicing of impeller of pump, replace of bearings and greasing,gland packing with bushing if required in all complete to the entire satisfaction and smooth functioning as directed by Engr In Charge. |
| 6 | M&L for repair & maint of 2.5 HP monoblock pump set including decoupling pump & motor, opening the body of motor and technically inspect , taking out burnt/defective winding wire carefully without damaging the stator, cleaning the slot, rewinding the stator with super enameled copper winding wire of existing gauge along with insulating material & varnishing if required and cleaning and servicing of impeller of pump, replace of bearings and greasing,gland packing with bushing if required in all complete to entire the satisfaction and smooth functioning as directed by Engr In Charge. |
| 7 | M&L for AMC of 1000 LPH RO Plant including servicing of raw water pump and high pressure pump ,rewinding of motor if required, servicing & maint of membranes , replace of high pressure switch ,low pressure switch and flow meter if required. Replace of filters and water purify chemicals required for smooth functioning of Plant etc in all complete as per directed by Engr-In-Charge. |
| 8 | M&L for AMC of 500 LPH RO Plant including servicing of raw water pump and high pressure pump ,rewinding of motor if required, servicing & maint of membranes, replace of high pressure switch ,low pressure switch and flow meter if required. Replace of filters and water purify chemicals required for smooth functioning of Plant etc in all complete as per directed by Engr-In-Charge. |
| 9 | M & L for repair,maintenance and servicing of 125 KVA DG set (Make-Kirloskar) complete including draining out of diesel, draining out engine oil from the sump, flushing the sump and cleaning, replacement of gaskets, fuel filters, oil filters, engine oil, air cleaner elements and the worn out parts like fuel flexible pipes, nuts, bolts, fuel line etc. Technically inspect and proper maint and servicing of all mechanical and electrical parts ie piston head, FIP assembly, self starting assembly, AVR, Engine and alternator coupling, control panel, filling the starting batteries with electrolyte, applying petroleum jelly in battery terminals poles, checking of voltage, amps, fuel, coolant and exhaust leakages etc including refilling radiator coolant , tightening all the nuts and bolts to the required torque, painting of DG Set with minor repair of equistic enclosure and testing to the entire satisfaction for smooth function in all respect as per directed by Engr-In-Charge. |
| 10 | Maint & servicing of 200 KVA power distribution transformer, 11/0.433 KV out door type, oil cooled including taking out the sample of transformer oil for checking the dielectric strength and top up of transformer oil as required ,taking all safety precautions so as to achieve dielectric strength not less 36 to 40 KV per minute rupturing capacity and switch on supply . Technically inspect of all bushing with guskets LT and HT side, replace the same if required, replace of silica jel on transformer breather, charging the transformer to entire satisfaction in all as directed by Engr-In-Charge. |
| 11 | Maint & servicing of 750 KVA power distribution transformer, 11/0.433 KV out door type, oil cooled including taking out the sample of transformer oil for checking the dielectric strength and top up of transformer oil as required ,taking all safety precautions so as to achieve dielectric strength not less 36 to 40 KV per minute rupturing capacity and switch on supply . Technically inspect of all bushing with guskets LT and HT side, replace the same if required, replace of silica jel on transformer breather, charging the transformer to entire satisfaction in all as directed by Engr-In-Charge. |
| 12 | Repair & maint of 1000 LPH RO Plant including servicing of raw water pump and high pressure pump ,rewinding of motor if required, servicing & maint of membranes and replace the same if required, replace of high pressure switch ,low pressure switch and flow meter if required. Replace of filters and water purify chemicals required for smooth functioning of Plant etc in all complete as per directed by Engr-In-Charge. |
| 13 | M&L for replacement of single phase split type AC out door unit fan motor 230 volt ,AC,50 Hz with copper bush including necessary power connection with testing complete. |
| 14 | M&L for replacement of capacitor of 3 mfd suitable for 1.5 ton capacity air conditioner including necessary connection with testing complete. |
| 15 | M&L for maint and servicing to air conditioner split/window type of 1.5/2 ton capacity including disconnecting power connection and removing front PVC grills , filters cleaning washing with chemical copper condenser coil and cooling coil servicing cleaning fans including minor repair and replacement of grill filters where ever required with re assembling dismantled component to its original position with testing grill temperature to the optimum efficiency of machine to the entire satisfaction for smooth functioning in all respect as per directed by Engr-in-Charge |
| 16 | Dismantling & taking down unserviceable sealed unit compressor from existing 1.5 ton split air conditioners of any make and replace the same by original manufacture / authorized dealer , 1.5 ton capacity sealed unit including necessary brazing and cleaning work and charging of refrigerant gas, including provision of new bushes, grommets, sleeves, washers , mounting rubbers , nuts bolts, terminal covers & clips, complete all as specified and directed with pressure testing complete to the entire satisfaction of Engr-in-charge. |
| 17 | M&L for refrigerant gas charging in split/window type air conditioner of any make/model as per desired pressure with minor repairs to copper tubing across including pressure testing for detection of leakages, vacuumsing etc complete to the entire satisfaction as directed by Engr-In-Charge. |
| 18 | Replacement of unserviceable fan motor with blade 1/32 Horse Power capacity suitable for water coolers 40/80 Ltr, complete all as specified and directed , Make:- AUE/Crompton |
| 19 | Dismantling & taking down unserviceable sealed unit compressor from existing water cooler 40/80 ltrs capacity of any make and replace the same by original manufacture / authorized dealer of same model including necessary brazing and cleaning work and charging of refrigerant gas complete all as specified and directed with pressure testing complete to the entire satisfaction of Engr-in-charge. |
| 20 | M&L for servicing of dessert cooler including replace of natural grass cleaner , water pipe, switches, regular if required, cleaning of water storage tank removing of old water and refilling fresh water and testing in all complete. |
| 21 | Replacement of unserviceable fan motor with blade suitable for dessert cooler complete all as specified and directed , Make:- AUE/ Havells / Crompton or equivalent |
| 22 | Replace of water pump suitable for dessert cooler incl testing in all complete |
| 23 | M&L for repair & maint of 5 HP monoblock pump set including decoupling pump & motor, opening the body of motor and technically inspect , taking out burnt/defective winding wire carefully without damaging the stator, cleaning the slot, rewinding the stator with super enameled copper winding wire of existing gauge along with insulating material & varnishing if required and cleaning and servicing of impeller of pump, replace of bearings and greasing,gland packing with bushing if required in all complete to the entire satisfaction and smooth functioning as directed by Engr In Charge. |
| 24 | Replacement of capacitor 2.5 Mfd for ceiling fan of any make/model/sweep, complete. Make:- EPCOS/ NICCO/ USHA/ UNISTAR. |
| 25 | Rewinding the ceiling fan motor of 1200 mm sweep, with super enameled copper wire of appropriate gauge inc replacement of insulating materials such as laminated elytroid paper, sleeves, necessary varnishing with golden colour varnishing, greasing/oiling of bush and the bearing, replacement of missing/worn out nut, bolt& washer etc and lesting after reassembling the same complete all as specified and directed. |
| 26 | Rewinding the ceiling fan motor of 1400 mm sweep, with super enameled copper wire of appropriate guage inc replacement of insulating materials such as laminated lethroid paper, sleeves, necessary varnishing with golden colour varnishing , greasing/oiling of bush and the bearing, replacement of missing/worn out nut,bolt &washer etc and lesting after reassembling the same complete all as specified and directed. |
| 27 | Supply and Fixing Heating element of capacity 1.50 KW (any type), ISI marked, suitable for geyser of capacity 25Ltr complete all as specified and directed. |
| 28 | Supply and Fixing Heating element of capacity 1.50 KW (any type), ISI marked, suitable for geyser of capacity 35 Ltr complete all as specified and directed. |
| 29 | Supply and Fixing of Heating element of capacity 2 kW (cup type / triangular / threaded type), ISI marked, suitable for geyser of capacity 50Ltr complete all as specified and directed. |
| 30 | Replacement of Thermostat assembly 16 A,240 AC, ISI marked, suitable for geyser of capacity 25/35/ 50Ltr of any type / make complete all as specified and directed. Make:- Ditz / Universal /TTE/RACOLD Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysOct 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender