Civil Aviation Boards / Undertakings / PSU Closing in 17 days TDR #57908040

Tender For Carrying Of Civil & Mechanical Works For Shifting Of Pv Section To Ground Floor Ofhangar-1 West Ancillary Bldg. At Aiesl Engg. Premises Oap, Mumbai-400029.

Issued by Boards / Undertakings / PSU · Mumbai Suburban, Maharashtra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
28 Oct 2026
17 days left
EMD
46569
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai Suburban → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Carrying Of Civil & Mechanical Works For Shifting Of Pv Section To Ground Floor Ofhangar-1 West Ancillary Bldg. At Aiesl Engg. Premises Oap, Mumbai-400029.

BOQ

Name of Work:- Carrying of Civil & Mechanical works for shifting of PV Section to Ground Floor ofHangar-1 West Ancillary Bldg. at AIESL Engg. Premises OAP, Mumbai-400029.
Sl. No. Item Description
1Civil Works
2Mechanical Works
3Excavation
4Earth work in excavation by mechanical/manual means over areas exceeding 30 cm depth, 1.5 m width and 10 m² on plan, including getting out and disposal of excavated earth up to 50 m lead and lift up to 1.5 m, all complete as per directions of Engineer-in-Charge.
5Sub base
6Construction of granular sub-base with close graded material, Grade-II, size 53 mm to 0.075 mm, CBR 25, including mixing at OMC, spreading and compaction, all complete as per directions of Engineer-in-Charge.
7Providing, laying, spreading and compacting graded Stone aggregate
8Providing, laying, spreading and compacting graded stone aggregate 53 mm to 0.075 mm to WMM specification, including premixing with water at OMC and compaction with vibratory roller, all complete as per directions of Engineer-in-Charge.
9Concreting
10Providing and laying C.C. pavement of M-25 with ready-mixed concrete from batching plant, including laying, screed-board vibrator, vacuum dewatering, finishing, brooming etc, all complete as per directions of Engineer-in-Charge.
11Breaking flooring
12Breaking flooring/waterproofing/ cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge. Nominal concrete 1:3:6 or richer mix (including equivalent design mix)
13Removing Basin
14Dismantling W.C. Pan of all sizes including disposal of dismantled materials including malba all complete as per directions of Engineer-in-Charge.
15Removing Windows
16Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below
17Plastering
18Providing and laying internal plaster in C.M.(1:4) 12mm thick minimum, to brick masonry and/or concrete surfaces in any location and at all levels including cleaning and watering the surfaces, filling out hollows or out of plumb surfaces with mortar and finishing to correct line and plumb including scaffolding as and where required etc. complete.
19Plaster Breaking With dado
20Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
21Partition Wall
22Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry 100 mm/ 125 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement: 4 coarse sand). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.
23RCC for Lintel , Base for Cylinder & RCC slab over gutter with 2support beam
24Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources)
25Reinforcement for Lintel, Base for Cylinder & rcc slab over gutter with 2 support beam
26Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding ali complete above plinth level.Thermo-Mechanically Treated bars of grade more. Fe-500D.
27New Dado
28Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarsesand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
29Polymer Repair
30Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarsesand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
31Granite work
32Providing and laying Polished Granite stone for door frame/ventilator in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent etc as per EIC ,complete.
33Aluminium for Window/VentiIator for 3 new window
34Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall besmooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately):For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868.Minimum anodic coating of grade AC 15)
355 WPC Doors
36Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm², modulus of elasticity 850 N/mm² and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-in-Charge.
375 WPC Door Frame
38Providing and fixing factory-made single extruded WPC solid door frame/chowkhat, 50 × 100 mm, including mitre joints, PVC solvent cement, SS screws etc., complete.
39M.S. Door -1
40Structural steel work in single section. fixed with or without connecting plate, including cutling, hoisting, fixing in position and applying apriming coat of approved steel primer all complete.
41MS. sheet door with frame
42Providing and fixing I mm thick MS. sheet door with frame Of 40x40x6mm angle iron and 3 mm MS. gusset plates at thc junctions and corners,all necessary fittings complete, including applying a priming coat of approved steel primer.
43Butt Hinges
44Providing and fixing ISI marked aluminium butt hinges anodised ( anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete - 125x75x4mm
45Door Closer
46Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
47Tower bolts
48Providing and fixing aluminium tower bolts , ISI marked , anodised ( anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade , with necessary screws etc. complète
49Providing Aldrop
50Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete 300x16 mm
51CPVC Plumbing lineProviding and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
5215 mm nominal dia Pipes
5320 mm nominal dia Pipes
5425 mm nominal dia Pipes
55Waste pipe
56PVC blind pipe 150 mm dia as per IS: 12818
57Bib Cock
58Providing and fixing brass bib cock of approved quality 20 mm nominal bore
59Gun Metal gate valveProviding and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end)
6020 mm nominal bore
6125 mm nominal bore
62Angle stop cock
63Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 gms
64Paint
65Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats
66Putty
67Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
68SEP Painting
69Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work
70New Basin
71Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps including all fittings, etc all complete as per EIC.
72Nahani trap jali
73Providing and fixing Nahani trap jali complete.
74Debris
75Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
76Glass for ventilator/ Window
77Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
78Metallic False Ceiling
79Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams/sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T' of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by EIC.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation and backed with a black Glass fiber acoustical fleece.
80Floor Paint
81Throughly cleaning the surface of all dirt, scales, oil, grease and other foreign material etc. sealing of cracks by opening the cracks and filling the same with cement mortar mixed with admixtures and Providing & applying Floor guard paint with Minimum 2 coats or adequate no. of coats to give uniform finish of superior make as directed by EIC.
82MS cylinder storage stand/rack
83Steel work welded in built-up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required, in gratings, frames, guard bars, ladders, railings, brackets, gates and similar works etc, Complete as per EIC.
84Roofing shed
85Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete as per EIC.
86Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required,Complete as per EIC.
87Providing and fixing precoated galvanised steel sheet roofing accessoriesof total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15- 18 micronsusing self drilling/ self tapping screws complete as per EIC.
88Precoated GI gutter, 600 mm overall girth
89Precoated GI flashing/apron up to 600 mm
90Shifting of - 1) HST Rig (Qty. 1), 2) HST Water Jacket - Round shape (Qty.1, removal also included by cutting old anchor bolts qty. 4 from 1 feet dip pit ), 3) Mechanical Vice (Qty. 2, by cutting existing anchor bolts qty.8 removal also included), 4) Empty Oxygen and Nitrogen Cyilnders (Qty. 20), 5) Nitrogen Booster Pump (Qty.1), 6) Carbon Dioxide Booster Pump (Qty. 1), 7) Water Jacket Square Shape (Qty. 1), 8) Oxygen Flushing Machine (Qty.1),9) Oxygen Hot Air Blower (Qty. 1), 10) Oxygen Booster Pump (Qty. 1), 11) Oxygen Charging Platform (Qty. 1), 12) Oxygen charging regulator (Qty. 1), 13) Oxygen bottle inspection table (Qty. 1), 14) Pneumatic Vice (Qty. 1) and 15) Weighing Scale (Qty.1) from existing location ground floor Hangar 1 to proposed location of PV Section on ground floor Hangar 1.
91Fixation - 1) HST Round shaped Water Jacket (Qty.1) with the help of 4 anchor bolts in 1 feet pit. 2) Mechanical Vice (Qty.2)with the help of 8 anchor bolts in the flooring 3) Wall mounted existing brackets (Qty.2)with safety cage (nested wire require to be fabricate new ,Height 4 ft x Length 6 ft, Width 1 ft) 4) Pneumatic Vice (Qty.1) required to be fitted with the help of 4 anchor bolts in flooring.
92Pneumatic Supply line for 100 PSI - 1)HST Rig - from existing source to machine inlet port, 1/2\\" diameter MS pipe approximate length 10 M, with 100 PSI withstand capacity, with the required T/ Elbow/ union joints. 2) Nitrogen Booster Pump - from existing source point to pump inlet port - 1/2\\" diameter flexible hose approximate length 10 M. 3) Carbon Dioxide Booster Pump - from existing source point to pump inlet port 1/2\\" diameter flexible hose approximate length 10 M, 100 PSI withstand capacity. 4) CO2 pump to Regulator - from pump outlet port to regulator inlet port 1/2\\" diameter flexible hose 100 PSI withstand capacity approximate length 3 M. 5) Oxygen Flushing Rig - from existing source point to machine inlet port 1/2\\" diameter flexible hose, 100 PSI withstand capacity,approximate length 4M. 6) Oxygen Booster pump - from existing source point to pump inlet port 1/2\\" diameter flexible hose 100 PSI withstand capacity, approximate length 10 M. 7) Oxygen supply line from bulk cylinder to charging platform Pump 1/2\\" diameter metalic and flexible hose 3000 PSI withstand capacity approximate length 20 M. 8) Oxygen Hot Air Blower - from existing source point to machine inlet port 1/2\\" diameter, flexible hose 100 PSI withstand capacity, approximate length 5 M. 9) Pneumatic Vice -from existing source point to machine inlet port.
93Water Plumbing - 1) HST Rig - From existing Water source to HST Rig - MS steel 1/2\\" pipe Dia.pipe Length approx. 10 M - including all required accesseories like union, elbow etc. 2)Round Shaped Water Jacket - Existing source to Water Jacket MS Steel, 1/2\\" diameter pipe length approx. 4 M 3) Water Jacket to HST Rig MS Steel 1/2\\" diameter pipe length approx. 4 M 3) Mechanical Vice (Qty.2) - from existing source to nearby both mechanical vice, MS pipe, 1/2\\" diameter, approx. length 10 M with required T/ Elbow/ union joints and tap. 4) Square shaped Water Jacket - existing source to location MS 1/2\\" diameter approx length 5 M with all required T/ Elbow/ Union. 5) Wash basin nearby Oxygen work area.
94Electrical work - 1) Make necessary wiring for Flame proof lights (Qty.3) with flame proof switches in Oxygen area (Flameproof lights and Switches will be provided by AIESL). 2) Shift existing AC Units (Qty.2) with all required wiring and supply boards, for Oxygen area. 3) Change all old ceiling lights (Qty.10), lights will be provided by AIESL, no need of extra wiring. 4) Supply cable for 3 phase, 415 V, 30 Amp, Oxygen flushing machine, 1.5 sqmm, armoured copper cable, length - 5) Removal of existing exhaust fan from old location and refix the same at new location with necessary electrical wiring.
95Fabrication and installation of Duct - Aluminum duct size 1 ft x 1 ft, length 10 M,from Oxygen Flushing rig to exhaust. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57908040
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 28-10-2026
Authority
Authority Name Ai Engineering Services Limited
Work Description Tender for Carrying Of Civil & Mechanical Works For Shifting Of Pv Section To Ground Floor Ofhangar-1 West Ancillary Bldg. At Aiesl Engg. Premises Oap, Mumbai-400029.
Basic Detail
Tender No AIESL/BOM/MMD/EFD/PFD/171
Bidding Type Tender
Location
City Mumbai Suburban
State Maharashtra
Key Dates
Publish Date 07 Oct 2026
Submission Date 28 Oct 2026
Open Date 29 Oct 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 46569
Exemption Not Available
Document List
8b2046ce-ff2f-49df-8132-86f8a257b798.html
BOQ_342425.xls
Tendernotice_1.pdf
Tender_Document.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Oct 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
html

8b2046ce-ff2f-49df-8132-86f8a257b798.html

xls

BOQ_342425.xls

pdf

Tendernotice_1.pdf

pdf

Tender_Document.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders