Tender For Maintenance And Periodical Services To Lifts, Oxygen Pipeline At Mh, Dg Set, Solid Waste Management System At Pangode Mil Station Under Ge (Army) Trivandrum

Issued by Statutory Bodies & Commissions/Committees · Thiruvananthapuram, Kerala
Tender Value
29.93 Lakhs
Estimated cost
Bid Submission
22 Oct 2026
8 days left
EMD
59900
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvananthapuram → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Maintenance And Periodical Services To Lifts, Oxygen Pipeline At Mh, Dg Set, Solid Waste Management System At Pangode Mil Station Under Ge (Army) Trivandrum

BOQ

Name of Work:- MAINT AND PERIODICAL SERVICES TO LIFTS, OXYGEN PIPELINE AT MH, DG SET, SOLID WASTE MANAGEMENT SYSTEM AT PANGODE MIL STATION UNDER GE (ARMY) TRIVANDRUM
Sl. No. Item Description
1M&L for filling of new multigrade engine oil as per site requirement or as directed for DG sets of various capacities installed under GE (Army) Trivandrum including draining out used lubricant oil from the DG Set engine, cleaning of chamber, flushing out sludge accumulated in the oil chamber before filling new oil complete all as specified and directed.
2M&L for carrying out scheduled maintenance service of the DG sets of 320 KVA through manufacturer service engineer complete including replacement of elements of fuel filters, engine oil filters and air filter with gaskets checking the engine for any leakages adjusting engine belt tension topping up radiator coolant etc complete all as directed by Engr-in-Charge.Note : Contractor should provide complete service from concerned company and provide service report to office after completion of the the service. Engine oil/ coolant required for servicing the DG set will be measured and paid separately under relevant items.
3All as per ser item No. 2 above but for DG set of capacity 160 KVA
4All as per ser item No. 2 above but for DG set of capacity 100 KVA
5All as per ser item No. 2 above but for DG set of capacity 62.5 KVA
6All as per ser item No. 2 above but for DG set of capacity 40 KVA
7All as per ser item No. 2 above but for DG set of capacity 30 KVA
8All as per ser item No. 2 above but for DG set of capacity 25/20 KVA
9M&L for repair/servicing of self starter including replacement of solenoid switch, rewinding of armature, carbon brush set, carbon brush holder and taping of field coil for the DG set of capacity 160 KVA complete all as specified and directed
10All as per ser item No. 9 above but for DG set of capacity 100 KVA
11All as per ser item No. 9 above but for DG set of capacity 62.5 KVA
12All as per ser item No. 9 above but for DG set of capacity 40 KVA
13All as per ser item No. 9 above but for DG set of capacity 30/25/20 KVA
14M&L for servicing/repair of charging alternator including replacement of diode, bush/bearing and varnishing of windings for DG set of capacity 320 KVA complete all as specified and directed
15All as per item No 14 above but for DG set capacity 160 KVA
16All as per ser item No. 14 above but for DG set of capacity 100 KVA
17All as per ser item No. 14 above but for DG set of capacity 62.5 KVA
18All as per ser item No. 14 above but for DG set of capacity 40 KVA
19All as per ser item No. 14 above but for DG set of capacity 30 KVA
20All as per ser item No. 14 above but for DG set of capacity 25/20 KVA
21M&L for repair and calibration of fuel pump and injectors as per calibration procedure and norms including replacement of pump element, injector nozzles and Orings/washers etc for DG set of capacity 320 KVA complete all as specified and directed
22All as per ser item No. 21 above but for DG set of capacity 160 KVA
23All as per ser item No. 21 above but for DG set of capacity 100 KVA
24All as per ser item No. 21 above but for DG set of capacity 62.5 KVA
25All as per ser item No. 21 above but for DG set of capacity 40 KVA
26All as per ser item No. 21 above but for DG set of capacity 30 KVA
27All as per ser item No. 21 above but for DG set of capacity 25/20 KVA
28S&F in replacement indicator lamp LED type complete assembly with holder suitable for 28 mm dia hole complete all as specified and directed
29S&F new existing size poly V-belt suitable for 320/160/100/62.5/40 KVA DG set including taking out existing unserviceable V belts complete all as specified and directed
30S&F V belts of size XPA 1250 Cogged of 30 KVA DG set including taking out existing unserviceable V-belt complete all as specified and directed
31S&F V belts of size B-47 1237 length of 25/20 KVA DG set including taking down existing unserviceable V-belt complete all as specified and directed
32S&F in replacement automatic voltage regulator (AVR) suitable for 320 KVA, 160KVA, 100 KVA, 62.5 KVA, 40 KVA, 30 KVA, 25 KVA & 20 KVA DG set including taking down the old unserviceable AVR complete all as specified and directed
33S&F in replacement digital type, 3 phase ammeter 0-100/200/300/400 Amps CT operated with 96x96 mm square flush mounting type complete all as specified and directed
34S&F in replacement CT coil 400/300/200/100/5 amps complete all as specified and directed
35S&F in replacement ammeter selector switches 10 Amps, line currents with OFF with CT complete all as specified and directed
36S&F in replacement voltmeter selector switches 10 Amps, voltage between phases & individual phases to neutral with OFF complete all as specified and directed
37S&F in replacement of MCCB Triple pole and Neutral (four pole) 63Amps, 415 volts, 50 Hz having adjustable thermal setting range 70% to 100% and fixed magnetic setting (Ics=100%Icu) with stainless steel enclosure and breaking capacity 16KA confirming to IS/IEC 60974-2 including dismantling of old unserviceable one and making incoming and outgoing connections to the new one complete all as specified and directed
38All as per ser item No. 37 above but for 100 Amps with 16 KA complete all as specified and directed
39M&L for draining out completely radiator coolant of different capacity of DG sets by loosen drain plug and then tighten the drain plug, slowly feed coolant of superior grade into the radiator through the filler unit radiator is full, squeeze the upper radiator house 2/3 times after coolant reaches the filler neck, close the radiator cap, testing after refilling complete all as specified and directed
40M&L for preparation of painted surfaces of the acoustic enclosure/DG sets of capacity 100KVA DG Set by scraping and removing rust and other objects and applying two coats of synthetic enamel paint of existing colour by spray painting over a coat of red oxide zinc chrome primer and making SM/MES No's and repairing and greasing door hinges and locks complete all as specified and directed.
41All as per ser item No. 40 above but for DG set of capacity 40 KVA
42All as per ser item No. 40 above but for DG set of capacity 30 KVA
43All as per ser item No. 40 above but for DG set of capacity 25/20 KVA
44Supply and fix in repair turbo charger and removing old deteriorated parts, by replacing new for smooth functioning of DG set capacity 320 KVA complete all as specified and directed.
45All as per ser item No. 44 above but for DG set of capacity 160 KVA
46All as per ser item No. 44 above but for DG set of capacity 100 KVA
47All as per ser item No. 44 above but for DG set of capacity 62.5 KVA
48All as per ser item No. 44 above but for DG set of capacity 40 KVA
49All as per ser item No. 44 above but for DG set of capacity 30 KVA
50All as per ser item No. 44 above but for DG set of capacity 25/20 KVA
51M&L for dismantling the fuel/diesel tank, clean the inside surface and strainer, removing old deteriorated parts of pipe line from diesel tank to fuel filter, replacing new fuel flow line for smooth functioning, refixing the fuel tank complete all as directed for DG set capacity 320 KVA complete all as specified and directed.
52All as per ser item No. 51 above but for DG set of capacity 160 KVA
53All as per ser item No. 51 above but for DG set of capacity 100 KVA
54All as per ser item No. 51 above but for DG set of capacity 62.5 KVA
55All as per ser item No. 51 above but for DG set of capacity 40 KVA
56All as per ser item No. 51 above but for DG set of capacity 30 KVA
57All as per ser item No. 51 above but for DG set of capacity 25/20 KVA
58M&L for radiator cleaning after removing carefully the radiator assembly from the DG set and cleaning, brazing wherever required from the site and re assembling completely of DG set capacity 320 KVA complete all as specified and directed.
59All as per ser item No. 58 above but for DG set of capacity 160 KVA
60All as per ser item No. 58 above but for DG set of capacity 100 KVA
61All as per ser item No. 58 above but for DG set of capacity 62.5 KVA
62All as per ser item No. 58 above but for DG set of capacity 40 KVA
63All as per ser item No. 58 above but for DG set of capacity 30 KVA
64All as per ser item No. 58 above but for DG set of capacity 25/20 KVA
65Dismantling of all unserviceable electric wiring from the 20/25/30/40/62.5/100/ 160/320 KVA DG Set of any make connected between starting switch, self starter, dynamo and other sensing points and supply and fixing the new electric wiring as per existing with protected flexible conduit complete in all respect and testing for proper function of DG set complete all as specified and directed.
66Material and labour for overhauling of alternator by heating and varnishing rotor and stator assembly for getting proper IR value and reassemble the same of DG set capacity 100/62.5 KVA complete all as specified and directed.
67All as per ser item No. 66 above but for DG set of capacity 40/30/25/20 KVA complete all as specified and directed.
68Supply & spread loose filling with river sand inside the FOL store, cable duct in DG set room etc not exceeding 150mm thick layer including removing the old sand to a distance not exceeding 50 mtr from the starting point complete all as specified and directed.
69M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below normal ground level, connected to galvanised earth lead of GI strip of size 32x6mm by means of GI Bolts, Nuts, check nuts and washers of the earth and thimbles and other end of the earth strip connected to earthing test point and protected by galvanised iron pipe light grade 50mm bore from earth plate to Panel/DBs and water pipe 20mm bore GI medium grade raised up to a level of 50cm above ground level with plug at top, earthing pit in PCC (1:3:6) type C-1 RCC pre-cast (1:2:4 type B-1) cover slab of 50 mm thick using 8.00mm dia CTD bars reinforcement both ways at 140 mm centre to centre with handle, 20 mm bore GI pipe medium grade for watering pipe, wire mesh, funnel and providing charcoal or coke and salt in alternative layers of 15 cm including necessary earth work in soft/ loose soil, returning, refilling and removing of surplus soil to a distance not exceeding 50 mtr testing complete all as shown in electrical plate No-3 of MES Schedule Part-I of SSR-2009 complete all as specified and directed, including taking down existing unserviceable earthing complete all as specified and directed.
70Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m laid in front of LT panel and DG Set complete all as specified and directed.
71Supply and fixing new appropriate size battery terminal cable including hose clips, apply petroleum jelly on battery terminals, tighten the terminals and testing including dismantling the old/deteriorated battery terminal cables complete all as specified and directed
72Supply and install in replacement of on load change over switch 415 volt AC, 50Hz in steel sheet metal enclosure, 4 pole of capacity 63 Amps, confirming to IEC-947-3 staggered terminals, site convertable fuse version, interchangeable dual shaft position with site convertibility, to be provided into existing panel including dismantling of old unsv one and making electrical connections new one complete all as specified and directed by Engr-in-Charge.
73Supply and install in replacement of on load change over switch 415 volt AC, 50Hz in steel sheet metal enclosure, 4 pole of capacity 630 Amps, confirming to IEC-947-3 staggered terminals, site convertable fuse version, inter changeable dual shaft position with site convertibility, to be provided into existing panel including dismantling of old unsv one and making electrical connections new one complete all as specified and directed.
74Supply and fix in repair to 12 Volt Battery of 180 AH suitable for 320 KVA DG set complete all as specified and directed
75Supply and fix in repair to 12 Volt Battery of 150 AH suitable for 160 KVA DG set complete all as specified and directed
76Supply and fix in repair to 12 Volt Battery of 100 AH suitable for 100/62.5/40/30/25/20 KVA DG set complete all as specified and directed
77Material and labour for overhauling of auto main failure Panel by auth tech suitable for 320/160/100/62.5/40/30/25/20 KVA DG Sets complete all as specified and directed
78Supply and fixing in replacement of Double Door for generator set of capacity upto 100 KVA including taking down old unserviceable complete all as specified and directed. Note: Dismantling as per site requirement for repair and any minor parts required for making the DG set fully operational which is not mentioned in subsequent items i.e. Nuts, bolts, washer, hinges any welding work etc are deemed to be included in rates quoted.
79Removing grass, vegetation and bushes growing at all around DG Set area, premises and keep all the DG Set area neat and clean complete all as specified and directed. Note: Unit rate quoted deemed to include to keep the Area neat and clean throughout the period of contract.
80M&L for taking out old burnt winding of Feeder motor, cleaning the slots and re-winding of motor 0.5HP 3 Phase Feeder motor,1390 RPM,415 volts with suitable gauge super enamelled copper winding wire and providing insulation materials such as fibre/ glass, 3 phase motor including necessary transportation to workshop if any and bring back, reassembling/refixing complete all as specified and directed.
81M&L for taking out old burnt winding of Blower motor, cleaning the slots and re-winding of motor 1.0 HP 3 Phase blower motor,2830 RPM,415 volts with suitable gauge super enamelled copper winding wire and providing insulation materials such as fibre/ glass, 3 phase motor including necessary transportation to workshop if any and bring back, reassembling/refixing complete all as specified and directed.
82S&F in replacement of Tubular Heaters of capacity 1.5 KW-(400 degree centigrade) complete all as specified and directed.
83S&F in replacement of Thermocouple of range 100 to 600 Degree Centigrade length 400mm, 3/4 inch thread 12mm dia K type complete all as specified and directed.
84S&F in replacement of Scrubber Media Pall rings 25mm, SS 304 complete all as specified and directed.
85M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below normal ground level, connected to galvanised earth lead wire of size 4mm dia by means of GI Bolts, Nuts, check nuts and washers of the earth and thimbles and other end of the earth GI wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia from earth plate to Panel/DBs and water pipe 20mm dia GI medium grade raised up to a level of 50cm above ground level with plug at top, earthing pit in PCC (1:3:6) type C-1 RCC pre-cast (1:2:4 type B-1) cover slab of 50 mm thick using 8.00mm dia CTD bars reinforcement both ways at 140 mm centre to centre with handle, 20 mm dia GI pipe medium grade for watering pipe, wire mesh, funnel and providing charcoal or coke and salt in alternative layers of 15 cm including necessary earth work in soft/ loose soil, returning, refilling and removing of surplus soil to a distance not exceeding 50 mtr testing complete all as shown in electrical plate No-3 of MES Schedule Part-I of SSR-2009 complete all as specified and directed, including taking down existing unserviceable earthing complete all as specified and directed.
86S & f in repair rotational moulded polythene water storage tank 500 ltr capacity (Triple layers) hoisted and fixed in position incl dismantling of existing unsv water tank and connecting inlet and outlet pipe lines all as specified and directed.
87Supply and fix in repair gun metal globe or gate valve with iron wheel head, screwed both ends; confirm ISI mark IS-778 class 1 of size 20mm bore dia iron pipe complete all as specified and directed.
88S&F in repair PVC ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for 20 mm bore dia of iron/PC pipe (Minimum weight 210 gms) complete all as specified and directed.
89Supply and fix in repair UPVC high pressure /pasted pipe all as per ASTM-D-1785 sch 410, pasted pipe with working pressure 10 Kg /cm 2 of size 20 mm dia including all fittings, laid/fixed in trenches/ wall/floor all as specified including taking down the old UNSV pipes all as specified and directed.
90Material and labour for laying XLPE insulated, PVC inner sheathed, extruded PVC outer sheathed, LT underground cable, armoured with galvanised steel strip, heavy duty electric cable with stranded aluminium conductor of cross-sectional area 3.5 core 25 Sqmm, 1100 volts grade, as per IS 7098 (Part 1) 1988, laid in trench, fixed on wall/pole drawn through pipe etc including of provision of lugs & testing, including taking down old unserviceable LT UG cable complete all as specified and directed.
91Material and labour for laying XLPE insulated, PVC inner sheathed, extruded PVC outer sheathed, LT underground cable, armoured with galvanised steel strip, heavy duty electric cable with stranded aluminium conductor of cross-sectional area 3.5 core 70 Sqmm, 1100 volts grade, as per IS 7098 (Part 1) 1988, laid in trench, fixed on wall/pole drawn through pipe etc including of provision of lugs & testing, including taking down old unserviceable LT UG cable complete all as specified and directed.
92Material and labour for laying XLPE insulated, PVC inner sheathed, extruded PVC outer sheathed, LT underground cable, armoured with galvanised steel strip, heavy duty electric cable with stranded aluminium conductor of cross-sectional area 3.5 core 95 Sqmm, 1100 volts grade, as per IS 7098 (Part 1) 1988, laid in trench, fixed on wall/pole drawn through pipe etc including of provision of lugs & testing, including taking down old unserviceable LT UG cable complete all as specified and directed.
93Supply and laying 63 mm bore high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches including taking out old unserviceable pipes complete all as specified and directed.
94Supply and laying 40 mm bore high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches including taking out old unserviceable pipes complete all as specified and directed.
95Supply and fix in replacement of GI tube light grade galvanised with all fittings laid along the pole/in trenches / under road or floor of 40 mm bore including removing the damaged pipe complete all as specified and directed.
96Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of UG cable, pipe, pole, stay etc and getting out soft/ loose soil including bottom surface to required level complete all as specified and directed.
97Returning, filling in using soil obtained from excavation including spreading, levelling, watering and well ramming in layers not exceeding 25 Cm complete all as specified and directed.
98Removing excavated surplus soil to a distance not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed.
99Supply, fixing, testing and commissioning in replacement of surface mounted British standard/ din gas outlet for front loaded colour coded (O2-12 Nos, Air-09 Nos,Vac-12 Nos) incl taking down old one complete all as specified and directed.Note- Item should be ISO certified and approved by GE.Make-GHL/HMP/MEDFLOW/S KUMAR/G FLOW
100Supply, fixing, testing and commissioning in replacement of suitable probes for outlets matching probes for gas terminal units - oxygen, air and vaccum. The probe should comply with BS 5682 : 1988 for gases and vaccum. Matching probes with one end suitable for hose/flow meter and other end suitable for imported and indigenous medical gas terminal units which complies and fully meets with the latest standard HTM02-01 and C11 incl taking down old one complete all as specified and directed.Note- Item should be ISO certified and approved by GEMake-GHL/HMP/MEDFLOW/S KUMAR/G FLOW.
101Supply, fixing, testing and commissioning in replacement of BPC flow meters with humidifier bottle made of unbreakable( polycarbonate material and autoclavable at 121 degree centigrade) having control within a range 0-15 lpm (Calibration within + 10%). The flow meter body should be made of brass chrome plated materials including taking down old one complete all as specified and directed.Note- Item should be ISO certified and approved by GE.Make-GHL/HMP/MEDFLOW/S KUMAR/G FLOW.
102Supply, fixing, testing and commissioning in replacement of ward vaccum unit of light weight and compact with regulator collection jar of 600 ml made of unbreakable polycarbonate material and autoclavable at 134 degree centigrade with wall brackets for mounting the jar assembly on the wall (Indigenous) including taking down old one complete all as specified and directed.Note- Item should be ISO certified and approved by GE.Make-GHL/HMP/MEDFLOW/S KUMAR/G FLOW.
103Supply, fixing, testing and commissioning in replacement of Isolation valve 15 mm having 90 degree turn, ball type& non lubricated for gas including taking down old one complete all as specified and directed.Note- Item should be ISO certified and approved by GE.Make-GHL/HMP/MEDFLOW/S KUMAR/G FLOW.
104Supply, fixing, testing and commissioning in replacement of Area Alarms (for four gases viz oxygen , air, vaccum, nitrous oxide) units with audio and visual alarms while pressure is lower than recommended and including taking down old one complete all as specified and directed.Note- Item should be ISO certified and approved by GE.Make-GHL/HMP/MEDFLOW/S KUMAR/G FLOW.
105Supply, fixing, testing and commissioning in replacement of vaccum system 3 HP Belt driven type with motors and fittings with following specifications including taking down old Vaccum System complete all as specified and directedMake: IR/Aerotek/Anestaiwata.(i) Technical specification of Motor : Motor shall be Belt driven 3 Phase with Make Crompton/Kirloskar or equivalent, with Motor power of 3HP, RPM:500, Reservoir:500 Ltr for each motor including in built automatic control panel with auto cut switch Note- (i) Item should be ISO certified and approved by GE.(ii) Old Vaccum system shall be deposit to MES Office.
106Supply, fixing, testing and commissioning in replacement of Air Compressor system 3 HP Belt driven type oil free Air compressor with motors and fittings with following specifications including taking down old Air compressor complete all as specified and directedMake: AnestaIwata/Aerotek/NEC.(i) Technical specification of Motor : Motor shall be Belt driven 3 Phase with Make Crompton/Kirloskar or equivalent, with Motor power of 3HP, RPM:1440, Reservoir:280 Ltrs for each motor, Working pressure 8.5 kg/cm2 with in built automatic control panel with auto cut switch .Note- (i) Item should be ISO certified and approved by GE.(ii) Old Air compressor system shall be deposit to MES Office.
107Supply, fixing, testing and commissioning in replacement of copper pipe and providing adequate supports while laying pipe lines to ensure that the pipe do not sag (medical grade as per BS 2871 ) of size 15 mm OD X0.9 mm including taking down old copper pipe complete all as specified and directed.Make-MEXFLOW or equivalent as approved by GE.
108Supply, fixing, testing and commissioning in replacement of copper pipe and providing adequate supports while laying pipe lines to ensure that the pipe do not sag (medical grade as per BS 2871 ) of size 22 mm OD X0.9 mm including taking down old copper pipe complete all as specified and directed.Make-MEXFLOW or equivalent as approved by GE.
109Supply, fixing, testing and commissioning in replacement of copper pipe and providing adequate supports while laying pipe lines to ensure that the pipe do not sag (medical grade as per BS 2871 ) of size 12 mm OD X0.9 mm including taking down old copper pipe complete all as specified and directed.Make-MEXFLOW or equivalent as approved by GE.
110Cutting, Chasing, making holes on wall and make good the damaged wall surface matching as per existing surface complete all as specified and directed.
111S&F in replacement of distribution board made out of sheet metal enclosure (CRCA sheet powder coated), dust and vermin proof, double door, TPN 4 way, 415 volts grade with 200 Amps insulated rated bus bar with nickel plated brass, isolated neutral bar and door earthing, earth bar IP- 43 protection with poly urethane (PU) gasketing, IK-08 Mechanical impact resistance, door earthing flush to wall, including testing suitable for enclosing/ fixing MCB SPN, SP etc including taking down existing unserviceable one from site and removing from site complete all as specified and directed.
112S&F in replacement of MCCB, triple pole and neutral (four pole), 100 Amp, 415 volts, 50 Hz, having thermal setting range 70% to 100% and adjustable magnetic setting and breaking capacity 16 KA including making incoming and outgoing connections complete all as specified and directed.
113Supply and fix in replacement of MCB triple pole neutral (MCB TPN), 415 volts, of capacity 32 Amps complete all as specified and directed.
114Supply and fixing in replacement of sub-main wiring with 4 runs of 6 sqmm single core PVC insulated, FRLSH, unsheathed cable with stranded copper conductor, 1100 Volts grade drawn through and including PVC conduit 20/25mm bore with all fitting such as Tees, Bends, Elbows, etc., fixed surface on wall/ceiling including 1 run of 6 Sqmm multistranded PVC insulated, FRLSH, copper conductor cable as earth continuity conductor and connecting to common earth dolly, including taking down old unserviceable wiring complete all as specified and directed.Note:- 4 runs of 6.0 sqmm copper cables and one run of 6.0 sq mm copper cable along with white colour PVC conduit/ conduit accessories will be measured as one unit length.
115Comprehensive maintenance and servicing of 01 No electrically operated bed cum passenger lift of make ECE and of 1360 KG capacity (for 20 persons) with 3 landings including ground floor (G+2), along with emergency rescue device, installed at MH at Pangode Military Station Trivandrum including attending day maintenance of lift and keeping the lift functional at all times complete all as specified and directed. Notes:- (a) Maintenance/repair work shall be carried out through trained service engineer as per maintenance schedule. (b) The contactor shall carry out the maintenance service of the lift every month. (c) Makes of the spare parts shall be of same make as used by original equipment manufacturer (OEM) or equivalent as approved. (d) Repair/replacement of any components rendered unserviceable due to wear and tear, such as, inverter system, controller parts, printed circuit boards, belts, rollers, gears, bearing, gear oil, solenoid coils, shaft lights, cabin door sensor, chokes, break shoes liners, contactor relay coils, push button, door locks, repair to lift motor, rewinding of cabin fan, ropes, indicators and other minor mechanical parts except major parts like, landing and car doors, ARD battery bank, lift cabin, guide rails, counterweights travelling cables etc, shall be deemed to be included in the comprehensive maintenance rate and no extra payment shall be given on this account.
116M&L for repair/ replacement of controller mother board, full collective all as specified and directed by Engr-in-Charge
117M&L for repair/ replacement of AC VVVF (variable voltage variable frequency) drive of 11 KW capacity all as specified and directed by Engr-in-Charge
118M&L Full load testing of 01 No electrically operated bed cum passenger lift of make ECE and of 1360 kg capacity (for 20 persons) complete all as specified and directed.
119M&L for repair/ replacement of ARD battery 12V 18AH to making ARD system functional (incl all items reqd to make system functional) complete all as specified and directed by Engr-in-Charge
120M&L for repair/ replacement of Automatic Rescue Device (ARD) 5KVA complete all as specified and directed by Engr-in-Charge
121Supply only Cabin Light fitting with LED Light suitable for bed cum passenger lift of any capacity complete all as specified and directed by Engr-in-Charge
122Supply only Cabin Fan suitable for bed cum passenger lift of any capacity complete all as specified and directed by Engr-in-Charge.
123M&L for replacement of Battery 12 Volts, 7 AH for operated emergency alarm unit complete all as specified and directed by Engr-in-Charge
124Supply and laying in repairs, PVC lift floor mat of approved shade and make complete all as specified and directed Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57908003
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 29.93 Lakhs
LAST DATE 22-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Maintenance And Periodical Services To Lifts, Oxygen Pipeline At Mh, Dg Set, Solid Waste Management System At Pangode Mil Station Under Ge (Army) Trivandrum
Basic Detail
Tender No 8427/E8
Bidding Type Tender
Location
City Thiruvananthapuram
State Kerala
Key Dates
Publish Date 07 Oct 2026
Submission Date 22 Oct 2026
Open Date 24 Oct 2026
Finance
Tender Value 29.93 Lakhs
Tender Fee 500
EMD 59900
Exemption Available
Document List
089d28e3-cd87-4f4a-bc64-31713c8bf741.html
8427Tender.pdf
BOQ_888850.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Oct 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

089d28e3-cd87-4f4a-bc64-31713c8bf741.html

pdf

8427Tender.pdf

xls

BOQ_888850.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender