Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #57907110

Bids Are invited for Custom Bid For Services - Structural Assessment Of 2 Overhead Water Tank Structure - Visual Inspection And Photography: Visual Survey Of The 2 Ohwt Structures; Recording/Mapping On Drawing To Assess Extent Of Spalled Concrete, Cr

Issued by Statutory Bodies & Commissions/Committees · Pune, Maharashtra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
17 Oct 2026
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Not Available
Quantity
1

Project Description

Bids Are invited for Custom Bid For Services - Structural Assessment Of 2 Overhead Water Tank Structure - Visual Inspection And Photography: Visual Survey Of The 2 Ohwt Structures; Recording/Mapping On Drawing To Assess Extent Of Spalled Concrete, Cracked Concrete, Honeycombing, Reinforcement Corrosion, Delaminated Concrete, Etc.; Photographs/Videos And Collection Of Evidence Of Damage. , Ultrasonic Pulse Velocity Test For Rcc Structure In Accordance With Is:516 Part-5-2018, Section 1, Using Portable Ultrasonic Non-Destructive Digital Test Equipment, Including Chipping Of Plaster At Strategic Locations. , Rebound Hammer Test For Rcc Structure In Accordance With Is:516 Part-5-2018, Section 4, Using Portable Digital Equipment At Strategic Locations. , Core Test: Core Cutting And Compression Test For Rcc Structure In Accordance With Is:516 On 70 Mm Core Cutting; Reinforcement, Core Filling By Specialised Epoxy Material/Micro Concrete With Bond Coat At Strategic Locations. , Reinforcement Mapping: Test On Rcc Members To Assess Cover, Spacing Of Bars Including Approximate Diameter At Strategic Locations. , Chemical Test For Rcc Structure In Accordance With Is:456-2000 Using Ready-Made Kits/Reagents. S Le Collected From Half-Cell/Carbonation Powder. (I) Determination Of Ph Value. (Ii) Determination Of Water-Soluble Sulphates. (Iii) Determination Of Water-Soluble Chlorides At Strategic Locations. , Half Cell Potential Test For Rcc Structure In Accordance With Is:516 Part-5-2018, Section 2, To Assess Probability Of Corrosion Of Reinforcement At Strategic Locations. , Carbonation Test For Rcc Structure In Accordance With Is:516 Part-5-2018, Section 3, To Measure Extent Of Carbonation From Concrete Surface At Strategic Locations. , To Check And Confirm Present Status Of Structure On Basis Of Ndt Results; Recommendation For Structure Repairs And Technical Specification & Serviceable Life Of 2 Ohwt. , Submission Of Boq And Estimate Including Providing List Of Repair Contractor.

BOQ

Sl. No. Item TitleItem Description
1Visual inspection and photography: Visual survey of the 2 OHWT structures; recording/mapping on drawing to assess extent of spalled concrete, cracked concrete, honeycombing, reinforcement corrosion, delaminated concrete, etc.; photographs/videos and collection of evidence of damage.Visual inspection and photography: Visual survey of the 2 OHWT structures; recording/mapping on drawing to assess extent of spalled concrete, cracked concrete, honeycombing, reinforcement corrosion, delaminated concrete, etc.; photographs/videos and collection of evidence of damage.
2Ultrasonic pulse velocity test for RCC structure in accordance with IS:516 Part-5-2018, Section 1, using portable ultrasonic non-destructive digital test equipment, including chipping of plaster at strategic locations.Ultrasonic pulse velocity test for RCC structure in accordance with IS:516 Part-5-2018, Section 1, using portable ultrasonic non-destructive digital test equipment, including chipping of plaster at strategic locations.
3Rebound hammer test for RCC structure in accordance with IS:516 Part-5-2018, Section 4, using portable digital equipment at strategic locations.Rebound hammer test for RCC structure in accordance with IS:516 Part-5-2018, Section 4, using portable digital equipment at strategic locations.
4Core test: Core cutting and compression test for RCC structure in accordance with IS:516 on 70 mm core cutting; reinforcement, core filling by specialised epoxy material/micro concrete with bond coat at strategic locations.Core test: Core cutting and compression test for RCC structure in accordance with IS:516 on 70 mm core cutting; reinforcement, core filling by specialised epoxy material/micro concrete with bond coat at strategic locations.
5Reinforcement mapping: Test on RCC members to assess cover, spacing of bars including approximate diameter at strategic locations.Reinforcement mapping: Test on RCC members to assess cover, spacing of bars including approximate diameter at strategic locations.
6Chemical test for RCC structure in accordance with IS:456-2000 using ready-made kits/reagents. Sample collected from half-cell/carbonation powder. (i) Determination of pH value. (ii) Determination of water-soluble sulphates. (iii) Determination of water-soluble chlorides at strategic locations.Chemical test for RCC structure in accordance with IS:456-2000 using ready-made kits/reagents. Sample collected from half-cell/carbonation powder. (i) Determination of pH value. (ii) Determination of water-soluble sulphates. (iii) Determination of water-soluble chlorides at strategic locations.
7Half cell potential test for RCC structure in accordance with IS:516 Part-5-2018, Section 2, to assess probability of corrosion of reinforcement at strategic locations.Half cell potential test for RCC structure in accordance with IS:516 Part-5-2018, Section 2, to assess probability of corrosion of reinforcement at strategic locations.
8Carbonation test for RCC structure in accordance with IS:516 Part-5-2018, Section 3, to measure extent of carbonation from concrete surface at strategic locations.Carbonation test for RCC structure in accordance with IS:516 Part-5-2018, Section 3, to measure extent of carbonation from concrete surface at strategic locations.
9To check and confirm present status of structure on basis of NDT results; recommendation for structure repairs and technical specification & serviceable life of 2 OHWT.To check and confirm present status of structure on basis of NDT results; recommendation for structure repairs and technical specification & serviceable life of 2 OHWT.
10Submission of BOQ and estimate including providing list of repair contractor.Submission of BOQ and estimate including providing list of repair contractor.

AI Tender Summary

OUR REF NO 57907110
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 17-10-2026
Authority
Authority Name Department Of Defence Production
Work Description Bids Are invited for Custom Bid For Services - Structural Assessment Of 2 Overhead Water Tank Structure - Visual Inspection And Photography: Visual Survey Of The 2 Ohwt Structures; Recording/Mapping On Drawing To Assess Extent Of Spalled Concrete, Cracked Concrete, Honeycombing, Reinforcement Corrosion, Delaminated Concrete, Etc.; Photographs/Videos And Collection Of Evidence Of Damage. , Ultrasonic Pulse Velocity Test For Rcc Structure In Accordance With Is:516 Part-5-2018, Section 1, Using Portable Ultrasonic Non-Destructive Digital Test Equipment, Including Chipping Of Plaster At Strategic Locations. , Rebound Hammer Test For Rcc Structure In Accordance With Is:516 Part-5-2018, Section 4, Using Portable Digital Equipment At Strategic Locations. , Core Test: Core Cutting And Compression Test For Rcc Structure In Accordance With Is:516 On 70 Mm Core Cutting; Reinforcement, Core Filling By Specialised Epoxy Material/Micro Concrete With Bond Coat At Strategic Locations. , Reinforcement Mapping: Test On Rcc Members To Assess Cover, Spacing Of Bars Including Approximate Diameter At Strategic Locations. , Chemical Test For Rcc Structure In Accordance With Is:456-2000 Using Ready-Made Kits/Reagents. S Le Collected From Half-Cell/Carbonation Powder. (I) Determination Of Ph Value. (Ii) Determination Of Water-Soluble Sulphates. (Iii) Determination Of Water-Soluble Chlorides At Strategic Locations. , Half Cell Potential Test For Rcc Structure In Accordance With Is:516 Part-5-2018, Section 2, To Assess Probability Of Corrosion Of Reinforcement At Strategic Locations. , Carbonation Test For Rcc Structure In Accordance With Is:516 Part-5-2018, Section 3, To Measure Extent Of Carbonation From Concrete Surface At Strategic Locations. , To Check And Confirm Present Status Of Structure On Basis Of Ndt Results; Recommendation For Structure Repairs And Technical Specification & Serviceable Life Of 2 Ohwt. , Submission Of Boq And Estimate Including Providing List Of Repair Contractor.
Basic Detail
Tender No GEM/2026/B/8128257
Bidding Type Tender
Location
City Pune
State Maharashtra
Key Dates
Publish Date 07 Oct 2026
Submission Date 17 Oct 2026
Open Date 18 Oct 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
e85af80c-2dfa-42fa-b704-6fb7ad3ebc25.pdf
1791362741.xlsx
1791362756.pdf
1791362762.pdf
1791362774.pdf
1791362822.pdf
1791363371.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

e85af80c-2dfa-42fa-b704-6fb7ad3ebc25.pdf

xlsx

1791362741.xlsx

pdf

1791362756.pdf

pdf

1791362762.pdf

pdf

1791362774.pdf

pdf

1791362822.pdf

pdf

1791363371.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender