Tender For Maintenance Of Electrical Installation In Non-Residential Building At Chandigarh. (Replacement Of Defective Electrical Accessories, Switchgear And Fitting Etc. In Various Shops I.E. Tyre Shop, Turner Shop, Electrician Shop, Gear Shop Servi
Tender Overview
Project Description
Tender for Maintenance Of Electrical Installation In Non-Residential Building At Chandigarh. (Replacement Of Defective Electrical Accessories, Switchgear And Fitting Etc. In Various Shops I.E. Tyre Shop, Turner Shop, Electrician Shop, Gear Shop Service Shop, Painter Shop, Fuel Injector Store Etc. In Ctu Depot No.1, U.T., Chandigarh).
BOQ
| Sl. No. | Item Description |
| 1 | DSR 1.23 Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. |
| 2 | 5/6 A switch |
| 3 | 15/16 amps switch |
| 4 | 3 Pin 5/6 A. socket outlet |
| 5 | 6 Pin 15/16 A. socket outlet |
| 6 | DSR item No.2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 7 | 100 A,30KA,FPMCCB |
| 8 | DSR 2.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 9 | 6 way, Double door |
| 10 | DSR item No. 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 11 | Single pole |
| 12 | Single Pole and Neutral |
| 13 | Triple Pole & Neutral |
| 14 | DSR item No.2.20 Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 15 | DSR item No.8.9 LED Batten light (System lumen efficacy ≥105 <120 lm/Watt). (Please refer DNIT for complete specification of item no.1) |
| 16 | 24- 26 Watt |
| 17 | DSR item No.8.16 LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt). (Please refer DNIT for complete specification of item no.1) |
| 18 | 100 Watt. |
| 19 | S/E of electronic fan regulator step type socket type in the existing bakelite sheet including cutting the sheet and making connection etc. The job includes all labour and petty material required to complete the job to the entire satisfaction of the Engineer-in-chaege of the work. The fan regulator should be of Anchor(Penta)/ Havells (Reo)/ SSK make only. |
| 20 | S/E of 3mm thick white glazed Bakelite sheet on the existing M.S box. The job includes the cost of sheets and making holes and cutting charges of switches & sockets. The job includes the cost of all labour & petty material required to complete the job. The Bakelite sheet should be of Superhylam/ Greenlam/ Formica make only. |
| 21 | Supply and laying of XLPE insulated PVC sheathed Aluminum conductor armoured cable of 1.1 KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid in existing Trench/Ducts/Cable Tray/ RCC/ HUME/ METAL/ DWC pipe / on surface with the help of MS clamps of suitable size/ as required at site to the entire satisfaction of Engineer-in-Charge. The job includes labour charges of laying the cable and making connections with suitable size aluminum lugs/thimbles etc. The cable shall be of Polycab / Havells / R.R. Kabel/ KEI/ Finolex make only. |
| 22 | 10 sq.mm 4 core (On surface) |
| 23 | S/E of stainless steel enclosure for MCCB 3 Pole / 4 pole. The enclosure shall be erected on existing angle iron board with nut bolts/ screws etc. to complete the job to the entire satisfaction of Engineer In Charge. The MCCB enclosure should be of Lauritz Knudsen/ Siemens/ Schneider/ Legrand / ABB Hanger make only. |
| 24 | 100/125/160 Amp. |
| 25 | Supply & erection MCB 4 pole 63 Amp 415 Volt 10KA Breaking Capacity ‘C’ curve without enclosure. The job includes the labour charges and other petty material required to complete the job. |
| 26 | Supply & erection of following rating on load change over switch with MS enclosure. The changeover switch should be of Havells/ Lauritz Knudsen/ Schneider/ABB/ Hager/ Legrand make only. The Changeover switch should be installed in existing cubicle panel / angle iron board/ including drilling holes in cubical panel / angle iron board, making connections with suitable rating of copper wire / copper strip etc. as required. The job includes the cost of all petty material and labour charge etc as required to complete the job to the entire satisfaction of Engineer-in-charge. |
| 27 | 63 Amp. 4 pole 415 Volt on load change over switch with MS enclosure. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender