Tender For Provision Of On-Grid Rooftop Solar Photovoltaic System At Rw Electrical,Mechanical , Ph Division,Bhubaneswar For The Year 2026-27_Building
Tender Value
15.12 Lakhs
Estimated cost
Bid Submission
20 Oct 2026
7 days left
EMD
15126
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Khordha → Odisha
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provision Of On-Grid Rooftop Solar Photovoltaic System At Rw Electrical,Mechanical , Ph Division,Bhubaneswar For The Year 2026-27_Building
BOQ
| Sl. No. | Item Description |
| 1 | S/F of computer board of 12 modular metal box with modular base & cover in recess including providing and fixing of consisting of 3 nos of 5amp modular switch and modular socket & 1 no of Mini MCB, connection, painting etc as required. (Make of Switch & Socket: Anchor / Cona/ Greatwhite/ Havells/ HPL/ Preeti) |
| 2 | Wiring for circuit / sub-main wiring along with earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20mm dia non metalic heavy duty flexible conduit 1.6mm in recessed PVC conduit as required (Make of wire: Finolex/ L&T / Anchor / Havels /HPL / V Guard/ KEI/ Greatwhite/ Polycab)-2x2.5+1x1.5 (1.8.2) |
| 3 | Supply, installation, testing & commissioning of 5KVA UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer of 1ph in put to 1 ph output,230V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 26AH, 20 No.s) protection for fault by OL,UV, EF,GF,OC,Ph. (Make: Numeric/APC/Vertiv/), as per direction of Engg.-in-Charge. Warranty period of all accessories & component & system must be 2 years & complete test certificate must be submitted along with ups including component list & SLD. for services building |
| 4 | S/F of 1.5T 3Star split type AC Machine with 16A Plugtop & 2.5sqmm 3core Cu cable as per the site requirement(Make-Carrier/Hitachi/Bluestar/LG/Mistubishi/O-General/Daikin) |
| 5 | Supply, installation, testing & commissioning of 24W Slim Edge-Lit LED Downlight (Round/Square) with die-cast aluminum body, white finish, glare-free diffuser, complete with LED driver and mounting accessories, suitable for 220-240V AC, 50Hz operation, high efficiency and long life. (Havells/crompton/philips/panasonic) |
| 6 | S/F of 4KVA Automatic Voltage Stabilizer(110-300V), (Make-Microtech/V-Guard) |
| 7 | Design, Supply, installation , testing , Integration & commissioning of ongrid Solar roof mounted Photo voltaic Power Plant conforming to MNRE specifications as amended, consisting of MONO BI-FICIAL TOPCON solar panel , net metering facility, necessary protections, earthing, mounted on Aluminium/GIstructure of suitable strength with following components complete as required:-a) Solar Photo voltaic Module of capacity (600-620)WP,144 cell or above, manufactured in India, conforming to IS14286/ IEC61215, IS/IEC61730-Part-1, IS/IEC61730-Part-2. Solar Photo voltaic Module conversion efficiency shall not be less than 16.5%. PVmodules used in solar power plants/ systems must be warranted for their out put peak watt capacity, which should not be less than 90% at the end of 10years and 80% at the end of 25 years. b)Power Conditioning Unit (PCU)of 350-800V DC Input voltage range and 400V AC, three phase, 4wire, 50Hz+/-2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3%and suitable for ambient temperature from 0 to 50 degree C. with 25 year warranty on solar module As per the direction of the Engineer-In-Charge. Design, Supply, installation , testing , Integration & commissioning of 10 KW ongrid Solar roof mounted Photo voltaic Power Plant along with generation meter as per the direction of Engineer-in-Charge - 17 Nos PV Solar Panel ( Make: Tata Power Solar/Waaree Energies/V-Guard/Luminous Solar/Microtek Solar/Equivalent) MNRE-approved 10KW grid-tied solar inverter with dual MPPT, minimum efficiency of 97.5%, and inbuilt protections. The inverter shall be IP65 or higher rated, suitable for outdoor installation, and capable of operating reliably in ambient temperatures from 25°C to +60°C. It shall feature a user-friendly LCD/LED display to show real-time operating status and performance metrics. The inverter must support net metering, comply with IEC/BIS standards, and include all necessary mounting accessories. A minimum warranty of 10 years shall be provided.-1 Set ( Make: V-Guard/Luminous /Microtek /Equivalent ) |
| 8 | Design, Supply, installation , testing , Integration & commissioning of ongrid Solar roof mounted Photo voltaic Power Plant conforming to MNRE specifications as amended, consisting of MONO BI-FICIAL TOPCON solar panel , net metering facility, necessary protections, earthing, mounted on Aluminium/GIstructure of suitable strength with following components complete as required:-a) Solar Photo voltaic Module of capacity (600-620)WP,144 cell or above, manufactured in India, conforming to IS14286/ IEC61215, IS/IEC61730-Part-1, IS/IEC61730-Part-2. Solar Photo voltaic Module conversion efficiency shall not be less than 16.5%. PVmodules used in solar power plants/ systems must be warranted for their out put peak watt capacity, which should not be less than 90% at the end of 10years and 80% at the end of 25 years. b)Power Conditioning Unit (PCU)of 350-800V DC Input voltage range and 400V AC, three phase, 4wire, 50Hz+/-2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3%and suitable for ambient temperature from 0 to 50 degree C. with 25 year warranty on solar module As per the direction of the Engineer-In-Charge. Design, Supply, installation , testing , Integration & commissioning of 8KW ongrid Solar roof mounted Photo voltaic Power Plant along with generation meter as per the direction of Engineer-in-Charge - 14 Nos PV Solar Panel ( Make: |
| 9 | 2-Year Comprehensive AMC Annual Maintenance Contract (AMC) after 1-year Defect Liability Period (DLP) to be carried out once every six months (two visits per year)@Rs. 632/- per KW/Year for next two years. including cleaning of PV modules, inspection of inverter/PCU, battery health check (electrolyte level/top-up if applicable), cable tightening, performance verification, preventive maintenance, and submission of service report (hardcopy and softcopy) (Per Year) . |
| 10 | S/F of 3corex6mm2 cord wire for AC machine. |
| 11 | S/F insulation foam covering both suction and discharge pipe line |
| 12 | S/F of PVC hard drainage pipeline system. |
| 13 | S/F of 1/2\\" and 1/4\\" copper pipe with insulation for S/T AC machine Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysOct 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender