Rural Development Government Departments Closing in 3 days TDR #57901051

Tender For Shfting Constn.Of R And B Road Sai Temple To Chatratota Via Khairpur,Dharapuar,Raghunathpur,Usuma,Salara,Patakula,Malipur Road Under Mmsy-Trip Deposited By Serw Kataka Vide Lr.No.9102.Dt.3.9.2026

Issued by Government Departments · Khordha, Odisha
Tender Value
64.70 Lakhs
Estimated cost
Bid Submission
20 Oct 2026
3 days left
EMD
64709
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Khordha → Odisha
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Shfting Constn.Of R And B Road Sai Temple To Chatratota Via Khairpur,Dharapuar,Raghunathpur,Usuma,Salara,Patakula,Malipur Road Under Mmsy-Trip Deposited By Serw Kataka Vide Lr.No.9102.Dt.3.9.2026

BOQ

Name of Work:- shfting constn.of R and B road Sai Temple to Chatratota via Khairpur,Dharapuar,Raghunathpur,Usuma,Salara,Patakula,Malipur road under MMSY-TRIP deposited by SERW Kataka vide lr.no.9102.dt.3.9.2026
Sl. No. Item Description
111 KV Cut Point with 90 Degree AnglePSC POLE 10 METER LONG 330 KG.
2PSC Pole Clamp(GI)
3Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each Channel(GI) length 1.2 mtr., 4 no's Channel(GI) required = (4x9.56x1.2)
4Fish Plate(GI) 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr., length, 15 no's required = (16x2.36x0.280)
5Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each Channel(GI) length 0.306 mtr., 4 no's Channel(GI) required = (4x9.56x0.306)
6Danger Plate, 1 no's.
7Back Clamp for danger Plate 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 1 no's = (1x0.59x0.510)
8GI barbed wire anticlimbing device 3 Kg, Per support
9Back Clamp for anticlimbing device 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 4 no's = (4x0.59x0.510)
1011 KV pin insulator polymer
11H W fitting(B&S) 70KN, 3Bolt
12Disc insulator (B&S) 70 KN polymer
13Earthing of Support ( Coil Type )
14No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr., For connecting pole with Coil earthing
15WEDGE CONNECTOR FOR 80 SQMM.CONDUCTOR
16POLYCARBONATE BIRD GUARD
17H.T. Stay clamp. 50x5 mm. Flat(GI), 3.14Kg/Mtr., 0.551 Mtr. Length, 2 no's qty. required (1 Pair)
18H.T. Stay set (Complete)
19H.T. Stay Insulator Type-C
207/10 SWG Stay Wire 15kg /stay
21GI Nut, Bolt & Washer of different sizes (7.433 Kg each Cut Pole)
22Black Paint(GIS Numbering & Zebra Stripping)
23Yellow Colour Paint(GIS Numbering & Zebra Stripping) for Background
24Civil & ServiceFixing of complete 11KV line Complete stay set includes1) Turn Buckle Assembly2) Stay Rod & Stay plate3) Stay Insulator4) Stay Wire.5) Stay clamps with Nuts & bolts BA will do the excavation including excavation, supply of0.5Cum cement concrete foundation 1:2:4 size (500mmx500mmx800mm) using 20mmBHG metal with all labour and material as per TPCODL Drawing & Standard.
25Concreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX1600mm) = 0.42Cu.mtr(Per Pole)
2611 KV Pin Points With WPBPSC POLE 10 METER LONG 330 KG.
27PSC Pole Clamp(GI)
2811 KV V cross Arm(GI) (10.2 K.g. each )
29Top bracket 100x50X6 mm GI Channel(GI) (2kg each)
30Danger Plate, 1 no's, for each pole
31Back Clamp for danger Plate 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 1 no's = (1x0.59x0.510)
32GI barbed wire anticlimbing device 3 Kg, Per support
33Back Clamp for anticlimbing device 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 4 no's = (4x0.59x0.510)
3411 KV pin insulator polymer, 3 Nos. required for each support
35Earthing of Support ( Coil Type )
36No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr., For connecting pole with Coil earthing
37GI Nut, Bolt & Washer of different sizes (1.45 Kg/ Pin Point)
3880 sq.mm AAA conductor
39Black Paint(GIS Numbering & Zebra Stripping)
40Yellow Colour Paint(GIS Numbering & Zebra Stripping) for Background
41POLYCARBONATE BIRD GUARD
42Civil & ServiceConcreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX1600mm) = 0.42Cu.mtr(Per Pole)
43DP With AB SwitchPSC POLE 10 METER LONG 330 KG.
44PSC Pole Clamp(GI)
45Top Channel(GI) 100X50X6mm, 9.50 KG/Mtr., each Channel(GI) length 3 mtr., 2 no's Channel(GI) required = (2x9.56x3)
46Fish Plate(GI) 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 8 no's required = (8x2.36x0.280)
47AB switch Mounting Channel(GI) 75X40X4.8mm, 7.14KG/Mtr., each Channel(GI) length 3 mtr., 2 no's Channel(GI) required = (7.14x3x2)
48AB Switch Side Support Channel(GI) 100X50X6mm, 9.56 KG/Mtr., each Channel(GI) length 0.35 mtr., 2 no's Channel(GI) required = (9.56x2x0.35)
49Channel(GI) Support for down Pipe 75X40X 4.8mm., 7.14KG/Mtr., each Channel(GI) length 0.8 Mtr., 1 no's Channel(GI) required = (7.14x0.8x1)
50Double Pole Belting Channel(GI) 75X40X 4.8mm., 7.14KG/Mtr., each Channel(GI) length 3 Mtr., 2 no's Channel(GI) required = (7.14x3x2)
5150x50x6mm,GI Bracing Angle(GI), 4.5Kg/mtr., each Angle(GI) length 3.512 mtr., 2 nos Angle(GI) required = (4.5x3.512x2)
52Danger Plate, 2 no's.
53Back Clamp for danger Plate 25X3 mm, Flat(GI), 0.59Kg/Mtr, Flat(GI) of 0.510mtr length 2 no's = (2x0.59x0.510)
54H.T. Stay clamp, 50X3 mm. Flat(GI), 3.14Kg/Mtr., 0.551 Mtr. Length, 2 no's qty. required ( 1 Pair)
55H.T. Stay set (Complete)
56H.T. Stay Insulator Type-C
577/10 SWG Stay Wire 15kg /slay
58GI Pipe Earthing 40mm. 3 Mtr. Long
5950x6mm Flat(GI) for earthing, 2.36kg/mtr., (12.5 Mtr. For L.A, 3 Mtr for AB Switch Body, 2.5 mtr. For mesh formation and 2.5 mtr. for raising)= 20.5x2.35
60GI barbed wire anticlimbing device 3 Kg. Per support, 2 no's qty. required =(2x3kg)
61Back Clamp for anticlimbing device 25X3 mm. Flat(GI), 0.59Kg/Mtr, Flat(CI) of 0.510mtr length 8 no's = (6x0.59x0.510)
62Lightning Arrester(12KV,10KA) (Station Class,class-2)
63AB Switch (11KV,400A,3pole,50Hz)
6411 KV pin insulator polymer
65H W fitting(B&S) 70KN, 3Bolt
66Disc insulator (B&S) 70 KN polymer
67WEDGE CONNECTOR FOR 55 SQMM.CONDUCTOR
68POLYCARBONATE BIRD GUARD
69GI Nut, Ball & Washer of different sizes (13.718 Kg each DP with AB Switch)
70Black Paint(GIS Numbering & Zebra Stripping)
71Yellow Colour Paint(GIS Numbering & Zebra Stripping) for Background
72Civil & ServiceFixing of complete 11KV line Complete stay set includes1) Turn Buckle Assembly2) Stay Rod & Stay plate3) Stay Insulator4) Stay Wire.5) Stay clamps with Nuts & bolts (BA will do the excvation including excvation, supply of 0.5Cum cement concrete foundation 1:2:4 size ( 500mmx500mmx800mm) using 20mm BHG metal with all labour and material as per TPCODL Drawing & Standard.
73Concreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX1067mm) = 0.42Cu.mtr(Per Pole)
74Provide necessary civil material for construction of Earthling chamber, excavation &Installation of incuding earthingpipe dia up to 100mm dia for length of 3Mtr.Scope also includes necessary nutbolt, 25 Kg. Bentonite Power, connection & welding with incoming earth Flat(GI). The work to be executed as per TPCODL drawing & design
75Cut Point with 180 Degree AnglePSC POLE 10 METER LONG 330 KG.
76PSC Pole Clamp(GI)
77Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each Channel(GI) length 1.2 mtr., 2 no's Channel(GI) required = (2x9.56x1.2)
78Fish Plate(GI) 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 8 no's required = (8x2.36x0.280)
79Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each Channel(GI) length 0.306 mtr, 2 no's Channel(GI) required = (2x9.56x0.306)
80Danger Plate, 1 no's.
81Back Clamp for danger Plate 25X3 mm, Flat(GI), 0.59Kg/Mtr, Flat(GI) of 0.510mtr length 1 no's = (1x0.59x0.510)
82GI barbed wire anticlimbing device 3 Kg. Per support
83Back Clamp for anticlimbing device 25X3 mm. Flat(GI), 0.59Kg/Mtr, Flat(CI) of 0.510mtr length 4 no's = (4x0.59x0.510)
8411 KV pin insulator polymer
85H W fitting(B&S) 70KN, 3Bolt
86Disc insulator (B&S) 70 KN polymer
87Earthing of Support ( Coil Type )
88No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing
89WEDGE CONNECTOR FOR 55 SQMM.CONDUCTOR
90POLYCARBONATE BIRD GUARD
91GI Nut, Ball & Washer of different sizes (3.55 Kg each Cut Pole)
92Black Paint(GIS Numbering & Zebra Stripping)
93Yellow Colour Paint(GIS Numbering & Zebra Stripping) for Background
94Civil & ServiceConcreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX1067mm) = 0.42Cu.mtr(Per Pole)
9511 KV Cut Point with 90 Degree AnglePSC POLE 10 METER LONG 330 KG.
96PSC Pole Clamp(GI)
97Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each Channel(GI) length 1.2 mtr., 4 no'sChannel(GI) required =(4x9.56x1.2)
98Fish Plate(GI) 50x6 mm., 2.36 kg/Mir., each 0.280 mtr, length, 16 no's required = (16x2.36x0.200)(1x0.59x0.510)
99Straight Cross Arm 100X50X6 mm, 9.56 KG/Mtr., each Channel(GI) length 0.300 mtr., 4 no'sChannel(GI) required =(4x9.56x0.306)
100Danger Plate, 1 no's
101Back Clamp for danger Plate 25X3 mm. Flat(GI), 0.59Kg/Mtr, Flat(GI) of 0.510mtr length 1 no's =(1x0.59x0.510)
102GI barbed wire anticlimbing device 3 Kg. Per support
103Back Clamp for anticlimbing device 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 4 no's= (4x0.59x0.510)
10411 KV pin insulator polymer
105H W fitting(B&S) 70KN, 3Bolt
106Disc insulator (B&S) 70 KN polymer
107Earthing of Support ( Coil Type )
108No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr., For connecting pole with Coil earthing
109WEDGE CONNECTOR FOR 55 SQMM.CONDUCTOR
110POLYCARBONATE BIRD GUARD
111H.T. Stay clamp. 50x5 mm. Flat(GI), 3.14Kg/Mtr., 0.551 Mtr. Length, 2 no's qty. required ( 1 Pair)
112H.T. Stay set (Complete )
113H.T. Stay Insulator Type-C
1147/10 SWG Stay Wire 15kg /stay
115GI Nut, Bolt & Washer of different sizes (7,433 Kg each Cut Pole)
116Black Paint(GIS Numbering & Zebra Stripping)
117Yellow Colour Paint(GIS Numbering & Zebra Stripping) for Background
118Civil & ServiceFixing of complete 11KV line Complete stay set includes1) Turn Buckle Assembly2) Stay Rod & Stay plate3) Stay Insulator4) Stay Wire.5) Stay clamps with Nuts & bolts (BA will do the excvation including excvation, supply of 0.5Cum cement concrete foundation 1:2:4 size ( 500mmx500mmx800mm) using 20mm BHG metal with all labour and material as per TPCODL Drawing & Standard.
119Concreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX1067mm) = 0.42Cu.mtr(Per Pole)
12011 KV Pin Points With WPBPSC POLE 10 METER LONG 330 KG.
121PSC Pole Clamp(GI)
12211 KV V cross Arm(GI) (10.2 K.g. each )
123Top bracket 100x50X6 mm GI Channel(GI) (2kg each)
124Danger Plate, 1 no's, for each pole
125Back Clamp for danger Plate 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 1 no's = (1x0.59x0.510)
126GI barbed wire anticlimbing device 3 Kg, Per support
127Back Clamp for anticlimbing device 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 4 no's = (4x0.59x0.510)
12811 KV pin insulator polymer, 3 Nos. required for each support
129Earthing of Support ( Coil Type )
130No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr., For connecting pole with Coil earthing
131GI Nut, Bolt & Washer of different sizes (1.45 Kg/ Pin Point)
13255 sq.mm AAA conductor
133Black Paint(GIS Numbering & Zebra Stripping)
134Yellow Colour Paint(GIS Numbering & Zebra Stripping) for Background
135POLYCARBONATE BIRD GUARD
136Concreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX1067mm) = 0.42Cu.mtr(Per Pole)
137Part - iii: Construction of 2 no's of 11KV Line Protecting Guarding on Single Pole for Road Crossing.Guarding Channel(GI) 75x40x4.8 mm, 7.14 KG/Mtr., each Channel(GI) length 2.2 mtr., 4 no's Channel(GI) required =(4x7.14x2.2) (For Single Pole)
138No-6 GI wire (0.192 kg/mtr.) for Main String
139No-S GI wire (0.131 kg/mtr.) for lacing
140Eye Bolt (236mm, 16mm dia, 1.577kg/mtr.)
141Gi Pipe Earthing 40mm, 3 Mtr. Long
14250x6mm Flat(GI) for earthing, 2.36kg/mtr., (10.7 mtr For raising)= 10.7x2.36
143Civil & ServiceConstruction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation, soil treatment with bentonite powder, calculation of earth resistance, including installation of 3Mtr GI Pipe 40mm/50mm including welding of Flat(GI) around pipe.
144PART- iv : Shifting & Construction of one number of plinth for existing 11/0.43 KV, 250 KVA DSS.Plinth Mounted DSSPSC POLE 10 METER LONG 330 KG
1459 Mtr. long 300 Kg. PSC Pole
146Pole clamp for EYE hook for (XLPE aerial bunched Cable)
147EYE hook for XLPE Aerial bunched Cable
148Dead End Clamp suitable for messenger XLPE Aerial bunched Cable
149Pole Clamp
150LT Cable raising Channel(GI) 75x40x4.8 mm GI Channel(GI) (1000 mm long)(7.14Kg./Mir., 6 No's.) (Each 6x1.000x7.14= 42.84 Kg)
151Top Channel(GI) GI 100 X 50 X 6 MM (3000 mm long) (9.56Kg./Mir., 2 No's.) (Each 2x3.000x9.56= 57.36 Kg)
152Fish Plate(GI) 50x6 mm., 2.36 kg/Mir., each 0.280 mtr. length, 6 no's required = (6x2.36x0.280)
153AB Switch Mounting Channel(GI) 75x40x4.8 mm GI Channel(GI) (3000 mm long)(7.14Kg./Mir., 2 No's.) (Each 2x3.000x7.14= 42.84 Kg)
154AB Switch Side Support Channel(GI) 100X50X6mm,9.56 Kg/Mtr., each Channel(GI) longth 0.35 mtr., 2 no's Channel(GI) required = (9.56x2x0.35)
155Channel(GI) Support for down Pipe 75X40X 4.8mm., 7.14Kg/Mtr., each Channel(GI) longth 0.8 Mtr., 1 no's Channel(GI) required = (7.14x0.8x1)
156HG/ DO Fuse Mounting Channel(GI) 75x40x4.8 mm GI Channel(GI) (3000 mm long)(7.14Kg./Mtr., 2 No's.) (Each 2x3.000x7.14= 42.84 Kg)
157Cantilever Support Channel(GI) 75x40x4.8 mm GI Channel(GI) (810 mm long, 2 No's.) (7.14Kg./Mtr., 2 No's.) (Each 2x0.810x7.14= 11.57 Kg)
158Cantilever Support Angle(GI) 50 X 50 X 6MM GI (1282 mm long) (4.5Kg./Mtr., 2 No's.) (Each 2x1.282x4.5= 11.54Kg)
159Double Pole Bolting Channel(GI) 75X40X 4.8mm., 7.14KG/Mtr., each Channel(GI) length 3.0 Mtr., 2 no's Channel(GI) required = (7.14x3x2)
16050x50x6mm.GI Bracing Angle(GI), 4.5Kg./mtr., each Angle(GI) length 3.512 mtr., 2 nos Angle(GI) required = (4.5x3.512x2)
16150x6mm Flat(GI) for earthing, 2.36kg/mtr., (2.5x7 mtr. For mesh formation, 12 Mtr. For LA and 2.5 mtr. For raising, 11 mtr for AB switch, 2.8 mtr for HG Fuse, 5x2 mtr. for DTR Nutral, (1.3+4.5) Mtr. For DTR Body, 0.500 mtr for LTDB & AB Switch operating handle, 3 mtr. for Fencing) (Each 65.6x 2.36= 154.81 Kg)
162LT Distribution Box with MCCB, Aluminium Busbar for 3 Bay with kit kat fuse for 250 KVA S/S
16350 SQ.MM, AAAC XLPE Covered Conductor
1641Cx 400 mm2 LT XLPE Cable(Un-Armoured)
165LT Cable Supporting Channel(GI) 50 X 50 X 6 MM GI Channel(GI) (2000 mm long)(9.56 Kg/Mtr., 2 No's.) (Each 2x2.0x9.56 = 38.24 Kg)
166LT Cable Supproting Angle(GI), 50x50x6mm.GI 4.5Kg./Mtr., each Angle(GI) length 2 mtr., 4 nos Angle(GI) required = (4.5x4x2)
167Supply of 1.1kV, 4Core, 150 sqmm, XLPE insulation armoured -Aluminium UG cable from LTDB to Pole
168AB Switch(11KV,200A,3pole,50HZ)
169H.G.Fuse( 11KV,200A,3Pole)
170WEDGE CONNECTOR for 55 SQ.MM.CONDUCTOR
171POLYCARBONATE BIRD GUARD
172Disc insulator (B&S)70 KN polymer
173HW fitting (B&S)70KN(3boted)
174Lightning Arrester(12KV, 10KA) Station Class 2
17511KV pin insulator polymer
176HT stay set complete
177HT stay Clamp (1.9Kg/pair)
178HT stay insulator TYPE-C
1797/10 SWG GI stay wire, Grade -2 (15Kg./Set)
18040 mm Nominal bore Gl pipe (medium gauge) earthing device with 3 mir .Long
181Gl Nuts & Bolts of Assorted size (25 Kg/ DSS DP)
182GI barbed wire/Anticlimbing device (3Kg /Pole)
183Back Clamp for anticlimbing device 25X3 mm, Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 8 no's = (8x0.59x0.510)
184Danger plate 11kv
185Back Clamp for danger Plate 25X3 mm, Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 1 no's = (1x0.59x0.510)
186Name plate
187Yellow Colour Paint(GIS Numbering & Zebra Stripping) for Background
188Black Colour Paint(GIS Numbering & Zebra Stripping) for numbering
189Civil & ServiceConcreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX1700mm) = 0.425Cu.m(Per Pole) (For 10 Mtr
190PCC ratio 1:3:6(M-10 Grade) for DSS Area (3.5X2.5X0.1) = 0.875 Cu. mtr.
191Fixing of stay set with 0.5Cum. cement concrete foundation 1:3:6(M-10 Grade) size ( 900mmx600mmx900mm) using 40mm BHG metal with all labor and material except stay set, stay wire, stay insulator.
192Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonite powder , calculation of earth resistance, including installation of 3Mtr GI Pipe 40mm/50mm including welding of Flat(GI) around pipe.
193LTDB Plinth
194DTR Plinth
195Laying of 4 Cx 150 mm2 LT XLPE Cable
196Laying of 1.1kV cable from 400 to 1000sqmm
197SITC and Erection of GI Fencing with Gate
198Concreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX1500mm) = 0.375Cu.m(Per Pole) (For PSC Pole)
199Supply of AL Lugs suitable for 400 sq mm cable/conductor, Crimping with cable and Fixing/connecting include supply and erection of PVC Tape as per voltage requirement.
200Supply of AL Lugs suitable for 150 sq mm cable/conductor, Crimping with cable and Fixing/connecting include supply and erection of PVC Tape as per voltage requirement.
201Supp. and erection of double Compression Flameproof Type Glanding for armored Cable 1C 300-1000 sqmm including making hole in Base plate and dressing of cable along with vermin proofing property. Supply to be done as per TPCODL Spec and approved make dowells.
202Supply and erection of double Compression Flameproof Type Glanding for armored Cable 3.5/4C 120-185sqmm including making hole in Base plate and dressing of cable along with vermin proofing property Supply to be done as per TPCODL Spec and approved make dowells.
203PART v : Shifting & Construction of 3 no's of plinth for existing 11/0.43 KV, 63 KVA DSS.Plinth Mounted DSSWPB (GI) Pole 160x152 (11Mtr Long, 30.44KG/Mtr) - (Total Pole Weight with Base Plate & Stiffner =331.04 KG+10.74 KG= 341.58 KG)
2049 Mtr. long 300 Kg. PSC Pole
205Pole clamp for EYE hook for (XLPE Aerial bunched Cable)
206EYE hook for XLPE Aerial bunched Cable
207Dead End Clamp suitable for messenger XLPE Aerial bunched Cable
208LT Cable resting Channel (GI) 75x40x4.8 mm GI Channel(GI) (1000 mm long)(7.14Kg/Mtr., 3 No's.) (Each 3x1.000x7.14= 21.42 Kg)
209Top Channel (GI) GI 100 X 50 X 6 MM (3000 mm long)(9.56Kg/Mtr, 2 Nos.) (Each 2x3.000x9.56= 57.36 Kg)
210Fish Plate(GI) 50x6 mm, 2.36 kg/Mtr., each 0.200 mtr. length, 8 no's required = (6x2.36x0.280)
211AB Switch Mounting Channel(GI) 75x40x4.8 mm GI Channel(GI) (3000 mm long)(7.14Kg/Mtr., 2 No's.) (Each 2x3.000x7.14= 42.84 Kg)
212AB Switch Side Support Channel(GI) 100x50x6imm,9.56 KG/Mtr., each Channel(GI) length 0.35 mtr., 2 no's Channel(GI) required=(9.56x2x0.35)
213Channel(GI) Support for down Pipe 75X40X 4.8mm., 7.14Kg/Mtr., each Channel(GI) length 0.8 mtr., 1 no's Channel(GI) required=(7.14x0.8x1)
214HG/ DO Fuse Mounting Channel(GI) 75x40x4.8 mm GI Channel(GI) (3000 mm long) (7.14Kg/Mtr., 2 No's.) (Each 2x3.000x7.14= 42.84 Kg)
215Cantilever Support Channel(GI) 75x40x4.8 mm GI Channel(GI) (810 mm long, 2 No's.) (7.14Kg/Mtr., 2 No's.) (Each 2x0.810x7.14= 11.57 Kg)
216Cantilever Support Angle(GI) 50 X 50 X 6MM GI (1282 mm long) (4.5Kg/Mtr, 2 No's.) (Each 2x1.282x4.5= 11.54Kg)
217Transformer Base GI Channel(GI) 100 X 50 X 6 MM (3000 mm long) (9.56Kg/Mtr.) (Each 2x3.000x9.56= 57.36 Kg)
218Transformer Base Support GI Channel(GI) 100 X 50 X 6 MM (515 mm long) (9.56Kg/Mtr.) (2x0.515x9.56= 9.85Kg)
219Transformer Belting Angle(GI) 50 X 50 X 6MM GI (3000 mm long)(4.5Kg/Mtr.) (Each 2x3.0x4.5 Kg)
220Transformer Belting Support Angle(GI) 50 X 50 X 6MM GI (580 mm long)(4.5Kg/Mtr.) (Each 2x0.580x4.5= Kg)
221LTDB Mounting Angle(GI) 50 X 50 X 6MM GI (1000 mm long)(4.5Kg/Mtr.) (Each 2x1x4.5 Kg)
22250x6mm Flat(GI) for earthing, 2.36kg/mtr., (2.5x7 mtr. for mesh formation, 12 Mtr. For LA and 2.5 mtr. For raising, 11 mtr for AB switch, 2.6 mtr for HG Fuse, 5x2 mtr. for DTR Nuiral. (1.3+4.5) mir. For DTR Body, 0.500 mtr for LTDB & AB Switch operating handle, 3 mtr. for Fencing) (Each 65.6x 2.36= 154.81 Kg)
223LT Distribution Box with MCCB, Aluminium Busbar of single Bay with kit kat fuse for 63 KVA S/S
22450 SQ.MM. AAAC XLPE Covered Conductor
22514 Cx 95 mm2 LT XLPE Cable(Armoured) - FOR 63 KVA Trf.
22614 Cx 95 mm2 LT XLPE CABLE (Armoured) - FROM LTDB to Pole
227AB Switch 11KV, 200A, 3pole, 50Hz
228HG/FUSE 11KV,200A,3POLE
229WEDGE CONNECTOR FOR 55 SQMM.CONDUCTOR
230POLYCARBONATE BIRD GUARD
231Disc insulator (G&S) 70 KN POLYMER
232H W fitting (G&S)70KN(3bolled)
233Lightning Arrester(12KV, 10KA) Station Class 2
23411KV pin insulator polymer
235HT stay set complete
236HT stay Clamp (1.9kg/pair)
237HT stay insulator TYPE-C
2387/10 SWG GI stay wire, Grade -2 (15Kg / Set)
23940 mm Nominal bore Gl pipe (medium gauge) earthing device with 3 mtr.Long
240GI Nuts & Bolts of Assorted size (25 Kg/ DSS DP)
241GI Barbed wire/Anticlimbing device (3kg/Pole)
242Back Clamp for anticlimbing device 25X3 mm. Flat(Gl), 0.59Kg/Mtr, Flat(GI) of 0.510mtr length 8 no's = (8x0.59x0.510)
243Danger plate 11kv
244Back Clamp for danger Plate 25X3 mm. Flat(GI), 0.59Kg/Mtr, Flat(GI) of 0.510mtr length 2 no's = (2x0.59x0.510)
245Name plate
246Yellow Colour Paint(GIS Numbering & Zebra Stripping) for Background
247Black Colour Paint(GIS Numbering & Zebra Stripping) for numbering
248Civil & ServiceConcreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX1000mm) = 0.450Cu.mtr (Per Pole) (For WPB Pole)
249Concreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX450mm) = 0.113Cu.mtr (Per Pole)
250PCC ratio 1:3:6(M-10 Grade) For OSS Area (5X3X0.1) = 1.5 Cu. mtr.
251Fixing of stay set with 0.5Cum. cement concrete foundation 1:3:6(M-10 Grade) size ( 900mmx600mmx900mm) using 40mm BHG metal with all labor and material except stay set, stay wire, stay insulator.
252Construction Earthing chamber including Installation of earthing pipe.Making earthing chamber including excavation, soil treatment with bentonite powder, calculation of earth resistance, including Installation of 3Mtr GI Pipe 40mm/50mm Including welding of Flat(GI) around pipe.
253Laying of 4 Cx 95 mm2 LT XLPE Cable
254SITC and Erection of GI Fencing with Gate
255Concreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX1500mm) = 0.375Cu.mtr (Per Pole) (For PSC Pole)
256Supply of AL Lugs suitable for 95 sq mm cable/conductor, Crimping with cable and Fixing/connecting include supply and erection of PVC Tape as per voltage requirement.
257Supply and erection of double Compression Flameproof Type Glanding for armored Cable 3.5/4C 50-95sqmm including making hole in Base plate and dressing of cable along with vermin proofing properly. Supply to be done as per TPCODL Spec and approved make dowells.
258PART VI : Construction of LT OH line for 4.670 CKM by using 1.1 KV 4CX50 mm² + 1CX50 mm² +1CX16 mm² AB CablePlinth Mounted DSS9 Mtr. long 300 Kg. PSC Pole
259LT Stay set Complete
2607/12 SWG GI stay wire, Grade -2
261LT stay Clamp (1.40Kg/pair)
262LT Stay insulator
263Pole clamp for EYE hook for (XLPE Aerial bunched Cable)
264EYE hook for XLPE Aerial bunched Cable
265Dead End clamp suitable for messenger XLPE Aerial bunched Cable
266Suspension Clamp with EYE hook for ABC
2674CX50 mm² (P)+1CX50 mm²(M)+1CX16 mm²(Street Light) (LT AB Cable)
268Insulated piercing connector.Type-A-main 50 to 150 sq.mm & Tap-50 to 150 sq.mm
269GI Pipe Earthing (each 5th pole to earth)
270Coil Earthing
271No-6 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing
272Danger plate (LT)
273Back Clamp for danger plate 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.51mlr length 1 no's = (1x0.59x0.51)
274GI barbed wire anticlimbing device 3 Kg. Per support
275Back Clamp for anticlimbing device 25X3 mm, Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 8 no's = (8x0.59x0.510)
276GI Nuts & Bolts of Assorted size (25 Kg/ DSS DP)
277Yellow Colour Paint(GIS Numbering & Zebra Stripping) for Background
278Black Colour Paint(GIS Numbering & Zebra Stripping) for numbering
279Fixing of LT Complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire. 5)Stay clamps with Nuts & bolts, including excavation, supply of 0.5Cum cement concrete foundation 1:2:4 size (500mmx500mmx800mm) using 20mm BHG metal with all labour and material (Excavation of earth will be done of size 500X500X1500 mm.)
280Concreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX1500mm) = 0.375Cu.mtr(Per Pole)
281Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earth resistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of Flat(GI) around pipe.
282PART VII : Construction of LT OH line for 0.390 CKM by using 2C×35 mm² (P)+1C×25 mm²(M) AB Cable9 Mtr. long 300 Kg. PSC Pole
283LT Stay set Complete
2847/12 SWG GI stay wire, Grade -2
285LT stay Clamp (1.40Kg/pair)
286LT Stay insulator
287Pole clamp for EYE hook for (XLPE Aerial bunched Cable)
288EYE hook for XLPE Aerial bunched Cable
289Dead End clamp suitable for messenger XLPE Aerial bunched Cable
290Suspension Clamp with EYE hook for ABC
2912CX35 + 1X25 (LT AB Cable)
292Insulated piercing connector.Type-B-main 25 to 150 sq.mm & Tap-6 to 35 sq.mm
293GI Pipe Earthing (each 5th pole to earth)
294Coil Earthing
295No-6 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing
296Danger plate (LT)
297Back Clamp for danger Plate 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.51mlr length 1 no's = (1x0.59x0.51)
298GI barbed wire anticlimbing device 3 Kg. Per support
299Back Clamp for anticlimbing device 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.51mlr length 4 no's = (4x0.59x0.51)
300GI Nut, Bolt & Washer of different sizes (0.5 Kg/ Pole)
301Black Paint(GIS Numbering & Zebra Stripping)
302Yellow Colour Paint(GIS Numbering & Zebra Stripping) for Background
303Civil & ServiceFixing of LT Complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire. 5)Stay clamps with Nuts & bolts, including excavation, supply of 0.5Cum cement concrete foundation 1:2:4 size (500mmx500mmx800mm) using 20mm BHG metal with all labour and material (Excavation of earth will be done of size 500X500X1500 mm.)
304Concreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX1500mm) = 0.375Cu.mtr(Per Pole)
305Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earth resistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of Flat(GI) around pipe.
306Dismantalling MaterialsDismantling of 9/8 Mtr. PCC/Joist Pole
307Dismantling / Removal of MS Channel from Double Pole Structure /pole
308Dismantling of existing 11/0.4kV, 33/0.4kV, Three Phase Distribution Transformer 63KVA including removal of HT/LT leads, earth connections and unloading by crane if required.
309Dismantling of existing 11/0.4kV, 33/0.4kV, 250kVA Three Phase Distribution Transformer including removal of HT/LT leads, earth connections and unloading by crane if required.
310Dismantling of ACSR/AAAC 34/ 55mm2 from overhead line
311Dismantling of ACSR/AAAC 80/100 mm2 from overhead line
312Dismantling of varous size of LT AB Cable Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57901051
AUTHORITY Government Departments
TENDER VALUE 64.70 Lakhs
LAST DATE 20-10-2026
Authority
Authority Name Rural Works Department
Work Description Tender for Shfting Constn.Of R And B Road Sai Temple To Chatratota Via Khairpur,Dharapuar,Raghunathpur,Usuma,Salara,Patakula,Malipur Road Under Mmsy-Trip Deposited By Serw Kataka Vide Lr.No.9102.Dt.3.9.2026
Basic Detail
Tender No EERWELBBSR 29/ 2026-27
Bidding Type Tender
Location
City Khordha
State Odisha
Key Dates
Publish Date 07 Oct 2026
Submission Date 20 Oct 2026
Open Date 21 Oct 2026
Finance
Tender Value 64.70 Lakhs
Tender Fee 10000
EMD 64709
Exemption Not Available
Document List
b90ac3dc-84fd-449e-9c82-dc2d62684599.html
BOQ_612543.xls
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Oct 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

b90ac3dc-84fd-449e-9c82-dc2d62684599.html

xls

BOQ_612543.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender