Tender For miscellaneous Repair Works To Bond Stores And Strengthening Of Reinforced Cement Concrete Columns Of Shop Floor
Tender Overview
Project Description
Tender for miscellaneous Repair Works To Bond Stores And Strengthening Of Reinforced Cement Concrete Columns Of Shop Floor
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 22-Oct-2026 | Due date extension. | Date | 02-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | PART - A (Repairs and Rehabilation works to Stores in Yard) |
| 2 | Chip unsound/weak concrete material from beams, columns & walls of average thickness varies 25 to75mm with standard power driven percusision type or pneumatic chiesel of standard make as directed by engineer incharge including tappering all edges, making square shoulders of cavities etc., complete and disposal of debris to a lead of 100M and all as specified and directed by engineer including necessary scaffolding etc., (Nature of work is above 10m from GL) |
| 3 | Providing 15mm thick cement plastering of in CM (1:6) over the wall surface etc., including necessary scaffolding, labour, required materials and cement (PPC-Ramco /Ultratech) etc., complete all as directed. |
| 4 | Demolishing of RR/ PCC/ RCC/ Brick wall in Cement mortar by manually / mechanical means including stacking of serviceable material & handing over of useful materials to scrapyard / YCM Civil R&M section and disposal of unserviceable materials with in a 100M lead etc., complete all as directed by HSL |
| 5 | Providing plain cement concrete 1:2:4 nominal mix by using 20 mm aggregate and baby chips including mixing, depositing in position, tampering, finishing, curing including all materials & labbour etc., complete all as directed. |
| 6 | Providing modified polymer mortar with cement sand ratio in 1:3 using Nito-bond SBR @ 7 Lits per Bag of cement, average thickness of 20 mm over the primed surface using Nito-Bond SBR in 1:1:3 by volume (SBR:Water:Cement) with necessary scaffolding arrangements etc. including cleaning of rest on reinforcement and application of nito zinc primer of fosroc make etc., complete (Nature of work is above 10m from GL) |
| 7 | Providing Two(2) coats of white washing with suryacem / Hitech gold to walls surfaces after through scrapping, sand papering and cleaning the surface to give even shade etc., complete all as directed. |
| 8 | Applying putty of total thickness 1mm in two coats of approved brands Birla / JK / Asian to wall surfaces at all heights including applying suitable primer after through scrapping, sand papering and cleaning the old paint surface by manually / mechanically including necessary scaffolding and staging where ever required. Putty shall be finished till a smooth and even surface is achieved etc., complete all as directed. |
| 9 | Apply two coats of premium quality arcylic emulsion paint of interior grade of approved brand like Asian paints (Royal shine) / Berger (silky luxury) and manufacture, Including applying additional costs wherever required to achieve even shade and colour. where ever specified by Engineer including necessary scaffolding and staging where ever required etc., complete. |
| 10 | Apply two (2) Coats of Premium quality weather proof Exterior Emulsion paint of required shade to wall surfaces from approved brands Asian Paints (Apex Ultima), Berger (Life 10) as specified by Engineer-incharge including necessary scaffolding etc., complete all as directed. |
| 11 | Providing two(2) coats of synthetic enamel paint over a coat of zinc rich primer to wooden surafces / steel surfaces like doors, windows, grills etc., of required colour using approved branded paints like Asian / Berger / Nerolac, after removal of paint on old surface using wire brush or sand paper to give an even shade etc., complete all as directed |
| 12 | Providing and laying reinforced cement concrete work in nominal mix of 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III):3 graded stone aggregate 20mm nominal size), excluding the cost of centering, shuttering, finishing and reinforcement and including cost of cement (opc 53 Grade- UltraTech, ACC, Nagarjuna & KCP) and all materials & men etc., complete. |
| 13 | Supply and providing Thermo-Mechanically Treated (TMT) bars of grade Fe-500D Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete all as directed (Sail/RINL/Kamachi etc., or equavalent). |
| 14 | Providing water proof MS / Wooden centering and shuttering including strutting, propping for lintels and columns and whereever specified etc., including removal of form work complete etc., complete all as directed. |
| 15 | Construction of Brick work with common burnt clay F.P.S (Non-Modular) bricks of class designation 7.5 in superstructure above plinth level upto 10M height in all shapes and sizes in cement mortar 1:6 (1 Cement : 6 coarse sand) including cost of cement (PPC - Ramco), required materials and scaffolding / staging etc., complete all as directed. |
| 16 | Removal of existing damaged thermocol/ wooden or any kind of false ceiling and handed over to useful material to CE office and dispose the unservicable material to outside HSL premises complete all as directed |
| 17 | Providing and fixing false ceiling with 7 mm thick pre finished gypsum tile boards of Armstrong / USG knauf or equivalent make (Equivalent cost & Specifications) of Size 600 x 600 mm of approved texture, design and patterns, to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised powder coated iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 24x38 mm of length 3000 mm, cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to formgrid module of size 600 x 600 mm, suspended from ceiling usinggalvanised mild steel items (galvanizing @ 80 grains per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L- shape level adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphey wall/ partition with the help of plastic rawl plugs at 50mm center to center and 40 mm long dry wall S.S screws. The workshall be carried out as per specifications complete all as directed. |
| 18 | Clean the Rust, over and behind a reinforcement bars upto 25mm dia by manual methods hammering the rebar, using wire brush, chesieling to form a totally rust free finishing surface throughout length of bars complete all as directed including necessary scaffolding etc., |
| 19 | Supply and apply the NitoZinc primer of fosroc make to the existing prepared surface of reinforcing bars to protect from corrosion complete all as directed. |
| 20 | Supply and providing 4mm thick Pin-headed Glass panes to existing ventilators complete all as directed. |
| 21 | Removal of old wooden shutters including frame for doors, Windows, Ventilators etc., without any damage and same has been fixed in position after repairing with suitable materials including all consumables etc., complete all as directed. |
| 22 | Supply and providing Stainless Steel hardware item 150mm long Tower bolt for door |
| 23 | Supply and providing Stainless Steel hardware item 150mm long Handle for door |
| 24 | Supply and providing Stainless Steel hardware item 300mm long Aldrop for door |
| 25 | Supply and fix 50mm thick RCC (1:2:4) precast jollies including required scaffoldings and other materials etc., complete all as directed. |
| 26 | Disposal of debries, surplus excavated earth, wooden scrap, garbage and rubbish outside the HSL premises to private dumping yard up to 20Km lead (not to dump in HSL colony dumping area & surrounding areas) it is the responsibility of the firm to ensure no objection shall be raised by Muncipal authorities / from any bod. If any dispute arises the agency has to sort out at their own risk etc., complete all as directed. |
| 27 | Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m. |
| 28 | Remove and clean the silt from drain including disposal outside HSL completeas directed. |
| 29 | PART - B (Repairing all stores columns) Work to be carried out at +10M level |
| 30 | Chipping and removal of existing PCC/RCC surface upto required depth manually/mechanically including cleaning and disposal of debris upto a lead of 100M as directed by EIC. Please Enable Macros to View BoQ information |
| 31 | Chipping and removal of existing PCC/RCC surface upto required depth manually/mechanically including cleaning and disposal of debris upto a lead of 100M as directed by EIC. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 4 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender