Tender For Supply, Installation, Testing And Commissioning Of Central Heating System For The Education Centre Cum Library At Village Saspol.
Tender Value
20.40 Lakhs
Estimated cost
Bid Submission
15 Oct 2026
7 days left
EMD
40808
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Leh → Ladakh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply, Installation, Testing And Commissioning Of Central Heating System For The Education Centre Cum Library At Village Saspol.
BOQ
| Sl. No. | Item Description |
| 1 | Supply, installation, testing and commissioning of Central Heating System for the Education Centre cum Library at village Saspol. |
| 2 | ELECTRIC BOILER 100KW Hot Water Generator with cable 3.5 Core × 150 sq.mm 50 mtr Aluminium XLPE, PVC Sheathed, Armoured, 1.1 kV Grade CableSupply, Installation, Testing and Commissioning (SITC) of 100 kW Electric Hot Water Generator (Electric Boiler), vertical shell type, stainless steel construction, complete with control panel, SCR controller, digital thermostat, safety devices, insulation, accessories, and power cabling up to the transformer. The pressure vessel shall be designed for a working pressure of 6 kg/cm² (6 bar) and hydraulically tested at 9 kg/cm² (9 bar) or 1.5 times the design pressure, whichever is applicable, in accordance with the Indian Boiler Regulations (IBR), where applicable, or relevant IS/ASME standards insulluted with 10mmm resin bounded thick fiber glasswool 32kg/Mcube,cladded with 0.8mm aluminium sheet, voltage 240+10% per phase, 3 phase. control Digital step controllar/thermostat for individual steps, digital type thermometer for inlet,outlet pipe,with temperature setting , SCR base linear controler for hot water generator. SAFTY- Float switch, auido/visual alarm for low level and high temperature, pressure relief valve, door switch, safty thermostat complete job. |
| 3 | Pumps Brine circulation Monobloc Pump with 2hp single phase size 50x40mm mechanical seal with 3.9 lps at 20 Mtr Supply, installation, testing & commissioning of monoblock centrifugal pump driven by suitable capacity electric motor and mechanical seal bearing temperature upto 90 ºC for ethylene glycol of 20 Mtr head complete with accessories including cement concrete foundation and all as specified and directed of following flow rates (Makes: Grundfos / Wilo/ Salmson,Franklin) |
| 4 | Monobloc pump 1hp for brine feeding . (complete fitting with the expension tank with 20mm MS pipe). |
| 5 | TanksDay Oil TankDay oil storage tank. Supply, installation, testing and commissioning of Kerosene/ HSD Day service Tank rectangular MS (IS2062) construction with capacity of 990 Litres complete with inlet, outlet, overflow, drain and vent with flame arrestor,Tank will be made out of 4 mm MS sheet with supporting made out of minimum 50mm NB class ‘B’ pipe to keep tank base at minimum(1000mm) above FFL service platform will be provided.The tank should be provided with remote indications and level switches for on-off operation of transfer pump. Extra high level and extra low level alarm should be provided .Tank and structure will be painted with two coats of red oxide paint and duly painted. |
| 6 | Expansion TankExpansion tank/over Head tank . HDPE (tripple layer) with necessary connection , Insulation and Al.Cladding. The job also includes steel structure of suitable height to be placed at roof top and connected with 25mm ms pipe. Capacity 100 litres. |
| 7 | Hot Water Radiators confirming to EN442 standaeds.\\"Steel panel heating radiators conforming to EN442 standard, working pressure ranging from 10-13 bar having working temperature at 110°C ,complete with Top grilles and side covers as standard alongwith inlet valve, outlet valve, air purge valve and threaded plug as per OEM.Inlet Water Temp: 70˚COutlet Water Temp: 65˚CRoom Temp: 24+-2˚C \\"Type22 Convector 600mmx 2200mmfitted with supply and return valves. |
| 8 | Type22 Convector 600mmx 700mmfitted with supply and return valves. |
| 9 | Piping Supply/Return Piping\\"SITC of Heavy Duty MS Class \\"\\"C\\"\\" Pipes insulated with 2\\"\\" thick Glass wool of density 16Kg/M³ or 1\\"\\" thick Nitrile foam with aluminium cladding and including all fittings like steel brackets for suspended pipes,fasterers, flanges, TEE, Bends, Reducers etc. 50mm |
| 10 | SITC of Heavy Duty MS Class \\"C\\" Pipes coated with metal primer, white/silver paint/as per site engineer instruction and including all fittings like flanges, TEE, Bends, Reducers etc.25mm |
| 11 | Valve50 mm DIA (Ball Valve) |
| 12 | 40 mm DIA (Ball Valve) |
| 13 | 25 mm DIA(Ball Valve) |
| 14 | Misc. ItemsPressure Gauges Glycerine fillied as per specifications (80 mm Dial) |
| 15 | Thermometer as per specifications |
| 16 | Air release valves with isolation ball valves (25mm) |
| 17 | Y-Strainers 50mm ( C.I Flanged) |
| 18 | Y-Strainers 40mm ( C.I Flanged) |
| 19 | NRV 40mm |
| 20 | Main PanelLT Panels.(line diagram to be furnished before order for weightage) Supply, assembly, erection , testing & commissioning of dust, damp and vermin proof free standing CPRI approved factory built sheet steel enclosed LT main distribution board suitable for 3 Ph 415V 50 Hz fabricated out of 2.0 mm thick CRCA sheet duly spray painted complete Al. bus bar 300 Amp rating and ribbed with sheet of suitable size complete for heating system to be installed in Plant room. Incomer 200 A MCCB 4 pole manual change over 2nos , Phase indicating lights& control fuses -1 Set Voltmeter (0-500V) range with selector switch - 1 Set Amp meter (0-200A) range with C.T.S. of 200/5 ratio And selector switch 1 No , outgoing 160A, TPN MCB for circulation pumps with automatic starter with indicating lamps 0-60 A Ammeter with C T 3 Nos 16 A SPN MCB for boiler 3Nos 160A SPN MCB with stator for Glycol tranfer pumps 2Nos 16 A TPN MCB with stator for oil transfer pump 2 Nos. The control panel shall be provided with the copper bus bars dully insulated of required ratings and 3 in 1 digital Voltmeter / Ammeter / Frequency meter, indicators etc .ALL the cables need to be laied neatly via a suitable cable tray.Wiring: All internal control wiring shall be with 1100V grade, PVC insulated, copper wires (minimum 1.5 sq.mm for control, 4 sq.mm for CT circuits) with ferrules at both ends. |
| 21 | Earthing : DSITC of Maintenanace free earthing SITC of long life maintenance free electrolytic eathing system with 10 feet vertival k type copper not less than 2\\" (50.8mm) id AND NOT LESS than 0.08\\" (2.03mm) wall thickness which does not require manual addition of water. the system should be corrosion resistance prefilled with hygroscopic powder and provide with suitable breathing and leaching ports at the ends. Rated for high fault currents bas bars rateed for 10KA, fault current bus bar connection type as Terraweld to withhold temprreture of 7000c. the earthing port shall be designed and supplied with poly plastic port cover nonconductive, enviroment friendly and lockable. The job includes excavation of pit disposal of earth installation of rods refilling with suitable earth and leveling etc.Providing and fixing 6SWG dia G.I. wire on surface of in recess for loop earthing interconnecting main panel and other electrical equipment |
| 22 | Glycol Charge. Supplying of glycol concentrate along with the necessary additives and inhibitor in cognition in sealed barrels.Non toxic antifreeze (The right antifreeze product intended for use in heating boilers not automobile as the chemicals are different ) Propylene Glycol mixture is installed in the system to avoid costly water or mold contamination .The amount or volume of antifreeze need to add to reach a desired freezing temperature of -40˚C. |
| 23 | Providing and fixing M.V. danger notice plate of 200 mm x 150 mm, made of mild steel at least 2mm thick and vitreous enameled white on both sides and with inscription in signal red color on front side as required Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 15, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysOct 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender