Tender For Installation Of Dual Submersible Pump For An 8 Inch Borewell And Construction Of Water Storage Tank At Public Sector Himya Under The Midh Scheme Fy-2026-27
Tender Value
18.98 Lakhs
Estimated cost
Bid Submission
24 Oct 2026
16 days left
EMD
37960
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Leh → Ladakh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Installation Of Dual Submersible Pump For An 8 Inch Borewell And Construction Of Water Storage Tank At Public Sector Himya Under The Midh Scheme Fy-2026-27
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge.All kinds of soil : |
| 2 | Ordinary Rock |
| 3 | Dry stone pitching (any thickness) including cost of stones.On Horizontal |
| 4 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 5 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills, fillets etc upto floor V level, including curing but excluding the cost of centring, shuttering and finishing with.1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 6 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 7 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 8 | Centering and shuttering including strutting, propping etc. and removal of formfor:Foundations, footings, bases of columns etc. for mass concrete. |
| 9 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 10 | 12 mm thick cement plaster on the rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:4 (1 cement: 4 fine sand). including cost and carriage of all material from source to site of work. |
| 11 | Providing and fixing 1mm thick M.S sheet door with drame of 40x40x6mm angle iron and 3mm M.S.using M.S angle 40x40x6mm for diagonal braces |
| 12 | Filling of available earth (excluding rock) plinth, sides of foundation etc layer not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering lead up to 50 mtrs & lift upto 1.5 mtrs. |
| 13 | CARRIAGE OF MATERIALS By Mechanical Transport including loading, unloading and stacking. Cement & Steel (avg. lead 100km) |
| 14 | sand (avg. lead 50km) |
| 15 | Stone aggregate 20mm nominal size (avg. lead 50km) |
| 16 | Stone aggregate 40mm nominal size (avg. lead 50km) |
| 17 | Soling Stone (avg. 10km) |
| 18 | CARRIAGE OF MATERIALS By Manual Labour including loading, unloading and stacking (avg. lead 100m) Cement & Steel (avg. lead 100m) |
| 19 | Sand (avg. lead 10m) |
| 20 | Stone aggregate 20mm nominal size (avg. lead 100m) |
| 21 | Stone aggregate 40mm nominal size (avg. lead 100m) |
| 22 | Soling Stone (avg. 100m) |
| 23 | Providing, laying and fitting of 80mm dia G.I pipe conforming to IS 4984 : 2016 with latest amendments and conveying to work site including loading and unloading at both destinations lowering into the trenches, laying true to line and jointing of pipes by welding as per standard procedure and guidelines, including encasing the pipe around to a depth not less than 15 cms with soft earth or selected earth available from the excavation site, complete giving hydraulic test as per relevant ISI with all leads and lifts including testing commissioning, flange fittings .THE DEVITION/BEND IS TO BE FABRICATED FORM AVAILABLE G.I PIPE 80MM DIA . the job shall be inclusive of all costs and carriage complete job as directed by engineer incharge (Contractor will make own arrangements for procuring water for testing) including transportation charges from divisional store to site work. |
| 24 | Design, Supply and installation testing and commissioning of dual solar submersible pump, (Grundfos or equivalent parameter specification and Properties) discharge of 4-5LPS and hgead of 60Mtr .Nominal operating cell temperature (NOCT : 45+/- 20 C), Temperature Co-efficient at NOCT (-0.286 to 0-4), Maximium power at NOCT, Maximium power at STC, Performance Ration (79%to 82%),Module Efficiency (21 or more), Required system peak output power(with module orientation-south ) 400Wp or above, Capacity per module, Type ofModule (Nano perc) Nmber of cels in each module (as per provide)., CertificationStandards (Compliance as per specifications), Number of modules (as peprovider), IP rating for Module (IP 67), Weight (Kg) and size (LXHXWmm) of eachmodule (as per provider), IP rating for VFD and DB (IP 54 with additionalencloseure/ IP 65), Solar Cell Material (Mono perc), Percentage of depreciaition inperformance (as per provder) Minimum ower generation )(____)KWh/sq.M/DyProduct Warranty (Vendor to declare), PV Module (Minimum 12 years), VFD(minimum 2 Years), Installation Warranty (minimum 2 years), SystePerformance guarantee (minimum till break even) RIO/ Beak even (Years),TCO inINR (20 Years) (Indicate \\"-ve\\" for benefits), DP (Years), Note: Vendor shall beresponsible for solar power generation, Solar PV modules, Stainless steel solarsubmersible pump and motor, Motor controller, GI Mounting structure set, DCcable as persite requirement, Cable AC as per site requirement, Safety rope as perdiameter of pump, Chain pulley of 1 ton capacity. The job also include any otherCivil/ Mech. item required to make the system functional. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysOct 26, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender